application •	 for applications with high mechanical loads in
	 explosion endangered areas classified as
	 zones 1/2 and 21/22 (acc. ATEX 137)
•	 for use at very low temperatures
material •	 outer layer:	 high-grade, specially
	 	 formulated polyamide 12
•	 intermediate layer: spec. bonding compound
•	 inner layer:	 specially modified polyethylene
characteristics •	 electrostatically discharging           
•	 for indoor and outdoor applications
•	 very good UV-resistance
•	 very high mechanical load capacity and
	 low-temperature impact strength
•	 high abrasion resistance
•	 free from halogens and cadmium
•	 very good chemical properties
temperature range –50°C ... +90°C continuous, +150°C short-term
ATEX approved for:
–40°C ... +85°C continuous
specifications ATEX directive 94/9/EC (ATEX 95)
EN 1127-1, EN 60079-0, -7, -31
approval       1258       II 2G Ex eb IIC II 2D Ex tb IIIC
SEV 05 ATEX 0105
compatible with PMA Ex-System, Connectors and system supports
colour outer layer: black, inner layer: yellow
Three Layer Corrugated Conduit	
very flexible, medium-duty	 	 	
DB-Nr. 16130-03	 27.03.2012/YS	 	 1/3
Drei-Schicht-Wellrohr	
sehr flexibel, mittelschwer		
Einsatzbereich •	 für Anwendungen mit hoher mechanischer
	 Beanspruchung in explosionsgefährdeten Berei-
	 chen der Zonen 1/2 und 21/22 (nach ATEX 137)
•	 für Einsatz bei sehr tiefen Temperaturen
Material •	 Aussenschicht:	hochwertiges, speziell
	 	 formuliertes Polyamid 12
•	 Mittelschicht:	 spez. Haftungscompound
•	 Innenschicht:	 speziell modifiziertes Polyethylen
Eigenschaften •	 elektrostatisch ableitend
•	 für Innen- und Ausseneinsätze
•	 sehr gute UV-Beständigkeit
•	 sehr hohe mechanische Belastbarkeit und
	 Kälteschlagfestigkeit
•	 hohe Abriebfestigkeit
•	 halogen- und cadmiumfrei
•	 sehr gute chemische Eigenschaften
Temperaturbereich –50°C ... +90°C kontinuierlich, +150°C kurzzeitig
für ATEX-Anwendung:
–40°C ... +85°C kontinuierlich
Spezifikationen ATEX-Richtlinie 94/9/EG (ATEX 95)
EN 1127-1, EN 60079-0, -7, -31
Zulassung 1258 II 2G Ex eb IIC II 2D Ex tb IIIC
SEV 05 ATEX 0105
passend zu PMA Ex-System, Verschraubungen und Systemhalter
Farbe Aussenschicht: schwarz, Innenschicht: gelb
PMA AG (Headquarters) · Aathalstrasse 90 · 8610 Uster · Switzerland · Tel: +41 44 905 61 11 · Fax +41 44 905 61 22 · info@pma.ch · www.pma.ch
Dimensions	 Dimensionen
Technical Data Sheet	 Technisches Datenblatt
XESX Index
min.	 max.
ductility	 Biegbarkeit
fatigue / reversed bending	 Dauer- / Biegewechselfestigkeit
pressure resistance	 Druck- / Trittfestigkeit
cold temperature performance	 Kälteeigenschaften
weather resistance	 Witterungseigenschaften
Fine profile T
Feinprofil T
Tight bend radius
Enge Biegeradien
Coarse profile G
Grobprofil G
High pull-out strength
Hohe Ausreisskräfte
Code reference	 Nr.-Schlüssel
X	 = 	multi layer	 Mehrschicht
ESX	 = 	type Ex	 Ex-Typ
G 	 = 	coarse profile	 Grobprofil
T 	 = 	fine profile	 Feinprofil
17 	 = 	nominal width	 Nennweite
	 	 outer layer:  	 Aussenschicht:
B 	 = 	colour-black	 Farbe schwarz
	 	 inner layer: 	 Innenschicht:
Y 	 = 	colour-yellow	 Farbe gelb
ESX BX YG 17-
XESX
PMA Ex-System 	
X-Serie
order no. conduit size rec. fitting thread dimensions in mm (nom.) weight packing unit
	 black / yellow NW metric 	 d1 d2 stat. R. dyn. R. kg/100 m PU/m
Bestell-Nr. Rohrgrösse empf. Verschrau-
bungs-Gewinde
Dimensionen in mm (nom.) Gewicht Verp.-Einheit
	 schwarz / gelb NW metrisch 	 d1 d2 stat. R. dyn. R. kg/100 m VE/m
	 XESXT-10BY 10 M12 / M16 	 9.2 12.8 25 	 65 	 3.0 	 50
	 XESXT-12BY 12 M16 / M20 	 11.8 15.6 30 	 70 	 4.2 	 50
	 XESXG-17BY 17 M20 / M25 	 15.2 21.0 35 	 85 	 7.0 	 50
	 XESXG-23BY 23 M25 / M32 	 22.0 28.5 40 	 110 	 10.5 	 50
	 XESXG-29BY 29 M32 / M40 	 27.5 34.4 50 	 130 	 14.0 	 50
	 XESXG-36BY 36 M40 / M50 	 35.8 42.4 60 	 180 	 18.5 	 30
	 XESXG-48BY 48 M50 / M63 	 46.8 54.4 70 	 220 	 25.0 	 30
	 Our customer service dept. or local distribution partner will be pleased to help you concerning product availability and lead time
	 Unser Kundendienst oder die lokale PMA-Vertretung gibt Ihnen über die Artikelverfügbarkeit und Lieferzeit gerne Auskunft
stat. R.	 =	 lowest recommended bending radius
	 	 for static (fixed) installation
	 	 kleinster empfohlener Biegeradius für
		 statische (feste) Verlegung
dyn. R.	 =	 lowest recommended bending radius
		for dynamic (flexible) installation
		 kleinster empfohlener Biegeradius für
	 	 dynamische (flexible) Verlegung
CABLE PROTECTION
KABELSCHUTZTECHNIK
PMA AG (Headquarters) · Aathalstrasse 90 · 8610 Uster · Switzerland · Tel: +41 44 905 61 11 · Fax +41 44 905 61 22 · info@pma.ch · www.pma.ch
Three Layer Corrugated Conduit	
very flexible, medium-duty	 	 	
DB-Nr. 16130-03	 27.03.2012/YS	 	 2/3
Drei-Schicht-Wellrohr	
sehr flexibel, mittelschwer		
Technical Data Sheet	 Technisches Datenblatt
XESX
PMA Ex-System 	
X-Serie
CABLE PROTECTION
KABELSCHUTZTECHNIK
properties 	unit 	value 	 test method according to
Eigenschaften 	Einheit 	 Wert 	 Prüfmethode nach
Mechanical properties Mechanische Eigenschaften
Impact strength Schlagfestigkeit	 (+85 °C) 	J 	 ≥ 7	 	 EN 60079-0
Schlagfestigkeit	 (–30 °C) 	J 	 ≥ 7 	 EN 60079-0
	J 	 > 6 	 PMA DO 9.21-4330
Compression strength Scheiteldruckfestigkeit 	N 	 > 300	 	 	 (50 x 50 mm) 	 PMA DO 9.21-4320
	N 	 > 600	 	 	(100 x 100 mm) 	
Reversed bending stresses Biegewechselfestigkeit 	cycles 	 > 200‘000 	 PMA DO 9.21-4420
	cycles 	 > 600‘000 	 PMA DO 9.21-4220
Pull-out resistance conduit/connect. Ausreissfestigkeit Wellrohr/Verschraub.: 	 	
PMA Ex-System, type IP66 PMA Ex-System, Typ IP66 	N 	 > 300 	 PMA DO 9.21-4610
PMA Ex-System, type IP68 PMA Ex-System, Typ IP68 	N 	 > 400
Testing at 23°C, 50% r.h., conduit   Prüftemperatur 23°C, 50% r.F., Rohr-
nominal width 17, unless otherwise nennweite 17, sofern nicht anders
stated angegeben
Thermal properties Thermische Eigenschaften
General: Allgemein: 	 	
Continuous application temperature Dauergebrauchstemperatur 	°C 	 –50 ... 	+90 	 PMA DO 9.21-4510
Upper application temperature obere Anwendungstemperatur 	°C 	 		 	 +110 	 20‘000 h
Short-term kurzzeitig 	°C 	 		 	 +150 	 168 h
For ATEX use: für ATEX-Anwendung:
Continuous application temperature Dauergebrauchstemperatur 	°C 	 –40 ... 	+85 	 EN 60079-0
Fire safety characteristics Brandschutzeigenschaften
Free from halogens and cadmium Halogen- und cadmiumfrei 	 	 	 yes / ja 	 DIN 53474
Electrical properties Elektrische Eigenschaften
Specific volume resistivity Spezif. Durchgangswiderstand 	Ω m 	 < 103
	 DIN IEC 60093
Specific surface resistivity Spezif. Oberflächenwiderstand 	Ω   	 < 106
	 DIN IEC 60093
Weathering resistance Witterungsbeständigkeit
Weathering (UV/humidity) Bewitterung (UV/Feuchte) 	 very good
For black colour für schwarze Farbe 	 sehr gut
Chemical properties Chemische Eigenschaften
Please refer to catalogue ersichtlich im Katalog PMA Ex-System
PMA Ex-System or www.pma.ch oder unter www.pma.ch
XESX
PMA Ex-System 	
X-Serie
PMA AG (Headquarters) · Aathalstrasse 90 · 8610 Uster · Switzerland · Tel: +41 44 905 61 11 · Fax +41 44 905 61 22 · info@pma.ch · www.pma.ch
The specifications and instructions for our customers in this document reflect the product engineering
level at the time of manufacturing. Please consider the valid data sheet release at a time. For questions
please contact the PMA customer service. PMA AG accepts no liability for damages resulting from un-
professional installation or application or misuse for a purpose. This disclaimer also includes damages
to third parties. It is the customer‘s responsibility to check the delivered products and immediately
notify PMA AG of detected faults. It is also the customer‘s responsibility to test the delivered product
on its applicability for the intended purpose. PMA AG will accept no liability or responsibility for their
products if a product or a PMA system is combined or used together with third-party products, i.e.
products from other companies than PMA AG. Jurisdiction in all legal disputes concerning product
liability have the courts of the canton of Zurich/Switzerland. Swiss law applies.
For more information and the newest data sheet releases go to: www.pma.ch
Die in diesem Dokument für unsere Kunden enthaltenen Angaben und Instruktionen entsprechen dem
neuesten Stand unserer Technik zum Zeitpunkt der Herstellung des Produktes. Es ist der jeweils gültige
Datenblattstand zu berücksichtigen. Bei Fragen wenden Sie sich bitte an den PMA-Kundendienst. Die
PMA AG lehnt jede Haftung bei unsachgemässer Montage oder Verwendung sowie Zweckentfrem-
dung des Produktes ab. Dieser Haftungsausschluss umfasst auch allfällige Drittschäden. Es obliegt dem
Kunden, die gelieferte Ware zu prüfen und allfällig festgestellte Mängel sofort der PMA AG anzuzeigen.
Es obliegt ferner dem Kunden, die Ware auf ihre Eignung zwecks einer spezifischen Anwendung zu
überprüfen. Die PMA AG lehnt jegliche Haftung für ihre Produkte ab, wenn ein einzelnes Produkt oder
ein PMA-System mit Fremdprodukten, d.h. Produkten anderer Unternehmungen kombiniert bzw. ver-
wendet wird. Gerichtsstand für Streitigkeiten bezüglich Produkthaftung sind die Gerichte des Kantons
Zürich/Schweiz. Es kommt Schweizer Recht zur Anwendung.
Ergänzende Informationen und neueste Datenblätter unter: www.pma.ch
Three Layer Corrugated Conduit	
very flexible, medium-duty	 	 	
DB-Nr. 16130-03	 27.03.2012/YS	 	 3/3
Drei-Schicht-Wellrohr
sehr flexibel, mittelschwer		
Technical Data Sheet	 Technisches Datenblatt
CABLE PROTECTION
KABELSCHUTZTECHNIK
properties 	unit 	value 	 test method according to
Eigenschaften 	Einheit 	 Wert 	 Prüfmethode nach
Environmental properties Umwelteigenschaften
RoHS compliant RoHS-konform 	 yes / ja	 	 EU Directive 2002/95/EC
Content of delivery Lieferumfang
Conduit Wellrohr
In addition to the national and international standards which consider mainly material properties and general product performance, PMA applies its own internally developed standards when assessing the system
suitability of cable protection products. The PMA standards are based on 30 years experience and allow a better assessment of whether a product is practically appropriate for a specific application.
Neben internationalen und nationalen Normen, die sich vor allem auf Materialeigenschaften und allgemeine Produkteigenschaften beziehen, wendet PMA ergänzend selbst definierte Werknormen zur Beurteilung
der Systemeigenschaften von Kabelschutzprodukten an. Diese erlauben auf der Basis über 30 jähriger Erfahrungen eine bessere Beurteilung der praktischen Eignung eines Produktes für spezifische Anwendungen.

Weitere ähnliche Inhalte

Ähnlich wie PMA Ex System XESX Three Layer Corrugated Cable Conduit - ATEX Hazardous Area Cable Conduits

Серводвигатели серии ESM Eibl DHT
Серводвигатели серии ESM Eibl DHTСерводвигатели серии ESM Eibl DHT
Серводвигатели серии ESM Eibl DHTArve
 
15 320 produktkatalog_rz_6_72dpi3
15 320 produktkatalog_rz_6_72dpi315 320 produktkatalog_rz_6_72dpi3
15 320 produktkatalog_rz_6_72dpi3beenkerkollegen
 
Bedienungsanleitung RESTEK MRIA+ Phono Pre
Bedienungsanleitung RESTEK MRIA+ Phono PreBedienungsanleitung RESTEK MRIA+ Phono Pre
Bedienungsanleitung RESTEK MRIA+ Phono PreHifi RESTEK
 
Bedienungsanleitung RESTEK MDAC+ Digitalvorverstärker
Bedienungsanleitung RESTEK MDAC+ DigitalvorverstärkerBedienungsanleitung RESTEK MDAC+ Digitalvorverstärker
Bedienungsanleitung RESTEK MDAC+ DigitalvorverstärkerHifi RESTEK
 
Conec Product News 2015
Conec Product News 2015Conec Product News 2015
Conec Product News 2015Urkunde
 
Die richtige Wahl für Ihren Einsatz. Temperatursensoren von ifm.
Die richtige Wahl für Ihren Einsatz. Temperatursensoren von ifm.Die richtige Wahl für Ihren Einsatz. Temperatursensoren von ifm.
Die richtige Wahl für Ihren Einsatz. Temperatursensoren von ifm.ifm electronic gmbh
 
Bedienungsanleitung RESTEK MSAT+ Tuner
Bedienungsanleitung RESTEK MSAT+ TunerBedienungsanleitung RESTEK MSAT+ Tuner
Bedienungsanleitung RESTEK MSAT+ TunerHifi RESTEK
 
Bedienungsanleitung RESTEK MCAB+ Tuner
Bedienungsanleitung RESTEK MCAB+ TunerBedienungsanleitung RESTEK MCAB+ Tuner
Bedienungsanleitung RESTEK MCAB+ TunerHifi RESTEK
 
Anleitung WAC 300
Anleitung WAC 300Anleitung WAC 300
Anleitung WAC 300Westaflex
 
Rückmeldesysteme für Hubventile und Schwenkantriebe
Rückmeldesysteme für Hubventile und SchwenkantriebeRückmeldesysteme für Hubventile und Schwenkantriebe
Rückmeldesysteme für Hubventile und Schwenkantriebeifm electronic gmbh
 
Bedienungsanleitung RESTEK EDITOR Vorverstärker
Bedienungsanleitung RESTEK EDITOR VorverstärkerBedienungsanleitung RESTEK EDITOR Vorverstärker
Bedienungsanleitung RESTEK EDITOR VorverstärkerHifi RESTEK
 
Anleitung Didactum AC Stromwandler / Strom-Messumformer
Anleitung Didactum AC Stromwandler / Strom-MessumformerAnleitung Didactum AC Stromwandler / Strom-Messumformer
Anleitung Didactum AC Stromwandler / Strom-MessumformerDidactum
 
Anschlagpunkte / Anschlageinrichtungen / Horizontale Lifelines
Anschlagpunkte / Anschlageinrichtungen / Horizontale LifelinesAnschlagpunkte / Anschlageinrichtungen / Horizontale Lifelines
Anschlagpunkte / Anschlageinrichtungen / Horizontale Lifelinessystema safety
 
Thames Side - Wägezellen- und Einbaulösungen für Silo-, Behälter- und Prozess...
Thames Side - Wägezellen- und Einbaulösungen für Silo-, Behälter- und Prozess...Thames Side - Wägezellen- und Einbaulösungen für Silo-, Behälter- und Prozess...
Thames Side - Wägezellen- und Einbaulösungen für Silo-, Behälter- und Prozess...Thames Side Sensors
 
Wartungs- und Bedienungsanleitung Elektrozylinder de/en
Wartungs- und Bedienungsanleitung Elektrozylinder de/enWartungs- und Bedienungsanleitung Elektrozylinder de/en
Wartungs- und Bedienungsanleitung Elektrozylinder de/enMöschle Thomas
 
Hướng dẫn sử dụng Testo 760
Hướng dẫn sử dụng Testo 760Hướng dẫn sử dụng Testo 760
Hướng dẫn sử dụng Testo 760Tenmars Việt Nam
 
Bedienungshandbuch RESTEK MINIRIA+
Bedienungshandbuch RESTEK MINIRIA+Bedienungshandbuch RESTEK MINIRIA+
Bedienungshandbuch RESTEK MINIRIA+Hifi RESTEK
 

Ähnlich wie PMA Ex System XESX Three Layer Corrugated Cable Conduit - ATEX Hazardous Area Cable Conduits (20)

Серводвигатели серии ESM Eibl DHT
Серводвигатели серии ESM Eibl DHTСерводвигатели серии ESM Eibl DHT
Серводвигатели серии ESM Eibl DHT
 
15 320 produktkatalog_rz_6_72dpi3
15 320 produktkatalog_rz_6_72dpi315 320 produktkatalog_rz_6_72dpi3
15 320 produktkatalog_rz_6_72dpi3
 
Bedienungsanleitung RESTEK MRIA+ Phono Pre
Bedienungsanleitung RESTEK MRIA+ Phono PreBedienungsanleitung RESTEK MRIA+ Phono Pre
Bedienungsanleitung RESTEK MRIA+ Phono Pre
 
Catalogue
CatalogueCatalogue
Catalogue
 
Bedienungsanleitung RESTEK MDAC+ Digitalvorverstärker
Bedienungsanleitung RESTEK MDAC+ DigitalvorverstärkerBedienungsanleitung RESTEK MDAC+ Digitalvorverstärker
Bedienungsanleitung RESTEK MDAC+ Digitalvorverstärker
 
Conec Product News 2015
Conec Product News 2015Conec Product News 2015
Conec Product News 2015
 
Die richtige Wahl für Ihren Einsatz. Temperatursensoren von ifm.
Die richtige Wahl für Ihren Einsatz. Temperatursensoren von ifm.Die richtige Wahl für Ihren Einsatz. Temperatursensoren von ifm.
Die richtige Wahl für Ihren Einsatz. Temperatursensoren von ifm.
 
Ps353 100-120
Ps353 100-120Ps353 100-120
Ps353 100-120
 
Bedienungsanleitung RESTEK MSAT+ Tuner
Bedienungsanleitung RESTEK MSAT+ TunerBedienungsanleitung RESTEK MSAT+ Tuner
Bedienungsanleitung RESTEK MSAT+ Tuner
 
Bedienungsanleitung RESTEK MCAB+ Tuner
Bedienungsanleitung RESTEK MCAB+ TunerBedienungsanleitung RESTEK MCAB+ Tuner
Bedienungsanleitung RESTEK MCAB+ Tuner
 
Anleitung WAC 300
Anleitung WAC 300Anleitung WAC 300
Anleitung WAC 300
 
Rückmeldesysteme für Hubventile und Schwenkantriebe
Rückmeldesysteme für Hubventile und SchwenkantriebeRückmeldesysteme für Hubventile und Schwenkantriebe
Rückmeldesysteme für Hubventile und Schwenkantriebe
 
Bedienungsanleitung RESTEK EDITOR Vorverstärker
Bedienungsanleitung RESTEK EDITOR VorverstärkerBedienungsanleitung RESTEK EDITOR Vorverstärker
Bedienungsanleitung RESTEK EDITOR Vorverstärker
 
MANUAL DEL INTERRUPTOR.pdf
MANUAL DEL INTERRUPTOR.pdfMANUAL DEL INTERRUPTOR.pdf
MANUAL DEL INTERRUPTOR.pdf
 
Anleitung Didactum AC Stromwandler / Strom-Messumformer
Anleitung Didactum AC Stromwandler / Strom-MessumformerAnleitung Didactum AC Stromwandler / Strom-Messumformer
Anleitung Didactum AC Stromwandler / Strom-Messumformer
 
Anschlagpunkte / Anschlageinrichtungen / Horizontale Lifelines
Anschlagpunkte / Anschlageinrichtungen / Horizontale LifelinesAnschlagpunkte / Anschlageinrichtungen / Horizontale Lifelines
Anschlagpunkte / Anschlageinrichtungen / Horizontale Lifelines
 
Thames Side - Wägezellen- und Einbaulösungen für Silo-, Behälter- und Prozess...
Thames Side - Wägezellen- und Einbaulösungen für Silo-, Behälter- und Prozess...Thames Side - Wägezellen- und Einbaulösungen für Silo-, Behälter- und Prozess...
Thames Side - Wägezellen- und Einbaulösungen für Silo-, Behälter- und Prozess...
 
Wartungs- und Bedienungsanleitung Elektrozylinder de/en
Wartungs- und Bedienungsanleitung Elektrozylinder de/enWartungs- und Bedienungsanleitung Elektrozylinder de/en
Wartungs- und Bedienungsanleitung Elektrozylinder de/en
 
Hướng dẫn sử dụng Testo 760
Hướng dẫn sử dụng Testo 760Hướng dẫn sử dụng Testo 760
Hướng dẫn sử dụng Testo 760
 
Bedienungshandbuch RESTEK MINIRIA+
Bedienungshandbuch RESTEK MINIRIA+Bedienungshandbuch RESTEK MINIRIA+
Bedienungshandbuch RESTEK MINIRIA+
 

Mehr von Thorne & Derrick International

Isolation procedures for safe working on electrical systems and equipment by ...
Isolation procedures for safe working on electrical systems and equipment by ...Isolation procedures for safe working on electrical systems and equipment by ...
Isolation procedures for safe working on electrical systems and equipment by ...Thorne & Derrick International
 
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical EqptTHORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical EqptThorne & Derrick International
 
The Children North East Annual Golf Day Wednesday 9th May 2018
The Children North East Annual Golf Day Wednesday 9th May 2018The Children North East Annual Golf Day Wednesday 9th May 2018
The Children North East Annual Golf Day Wednesday 9th May 2018Thorne & Derrick International
 
3M Electrical Products Stocked By Thorne & Derrick International
3M Electrical Products Stocked By Thorne & Derrick International3M Electrical Products Stocked By Thorne & Derrick International
3M Electrical Products Stocked By Thorne & Derrick InternationalThorne & Derrick International
 
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-AThorne & Derrick International
 
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...Thorne & Derrick International
 
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...Thorne & Derrick International
 
Pepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
Pepperl & Fuchs SIL Training Certificate - T&D Adam RowePepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
Pepperl & Fuchs SIL Training Certificate - T&D Adam RoweThorne & Derrick International
 
Ultrasonic Flow Meters - Customer Specification Demand
Ultrasonic Flow Meters - Customer Specification DemandUltrasonic Flow Meters - Customer Specification Demand
Ultrasonic Flow Meters - Customer Specification DemandThorne & Derrick International
 
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282DSIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282DThorne & Derrick International
 
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...Thorne & Derrick International
 
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec SheetFiloform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec SheetThorne & Derrick International
 

Mehr von Thorne & Derrick International (20)

Isolation procedures for safe working on electrical systems and equipment by ...
Isolation procedures for safe working on electrical systems and equipment by ...Isolation procedures for safe working on electrical systems and equipment by ...
Isolation procedures for safe working on electrical systems and equipment by ...
 
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical EqptTHORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
 
The Children North East Annual Golf Day Wednesday 9th May 2018
The Children North East Annual Golf Day Wednesday 9th May 2018The Children North East Annual Golf Day Wednesday 9th May 2018
The Children North East Annual Golf Day Wednesday 9th May 2018
 
3M Electrical Products Stocked By Thorne & Derrick International
3M Electrical Products Stocked By Thorne & Derrick International3M Electrical Products Stocked By Thorne & Derrick International
3M Electrical Products Stocked By Thorne & Derrick International
 
CATU Electrical Safety Catalogue
CATU Electrical Safety CatalogueCATU Electrical Safety Catalogue
CATU Electrical Safety Catalogue
 
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
 
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
 
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
 
Roxtec Cable Transit - B Frame Dimensional Drawing
Roxtec Cable Transit - B Frame Dimensional DrawingRoxtec Cable Transit - B Frame Dimensional Drawing
Roxtec Cable Transit - B Frame Dimensional Drawing
 
Pepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
Pepperl & Fuchs SIL Training Certificate - T&D Adam RowePepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
Pepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
 
T&D Experts In Equipment For Explosive Atmospheres
T&D Experts In Equipment For Explosive AtmospheresT&D Experts In Equipment For Explosive Atmospheres
T&D Experts In Equipment For Explosive Atmospheres
 
Ultrasonic Flow Meters - Customer Specification Demand
Ultrasonic Flow Meters - Customer Specification DemandUltrasonic Flow Meters - Customer Specification Demand
Ultrasonic Flow Meters - Customer Specification Demand
 
Emtelle Fibre Optic Cables - Product Catalogue 2016
Emtelle Fibre Optic Cables - Product Catalogue 2016Emtelle Fibre Optic Cables - Product Catalogue 2016
Emtelle Fibre Optic Cables - Product Catalogue 2016
 
Thorne & Derrick Process Heating Brochure 2016
Thorne & Derrick Process Heating Brochure 2016Thorne & Derrick Process Heating Brochure 2016
Thorne & Derrick Process Heating Brochure 2016
 
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282DSIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
 
Ripley Utility Tool Cable Preparation Tools
Ripley Utility Tool Cable Preparation ToolsRipley Utility Tool Cable Preparation Tools
Ripley Utility Tool Cable Preparation Tools
 
RIDGID micro CD100 Combustible Gas Detector
RIDGID micro CD100 Combustible Gas DetectorRIDGID micro CD100 Combustible Gas Detector
RIDGID micro CD100 Combustible Gas Detector
 
Itron Fact Sheet
Itron Fact SheetItron Fact Sheet
Itron Fact Sheet
 
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
 
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec SheetFiloform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
 

PMA Ex System XESX Three Layer Corrugated Cable Conduit - ATEX Hazardous Area Cable Conduits

  • 1. application • for applications with high mechanical loads in explosion endangered areas classified as zones 1/2 and 21/22 (acc. ATEX 137) • for use at very low temperatures material • outer layer: high-grade, specially formulated polyamide 12 • intermediate layer: spec. bonding compound • inner layer: specially modified polyethylene characteristics • electrostatically discharging • for indoor and outdoor applications • very good UV-resistance • very high mechanical load capacity and low-temperature impact strength • high abrasion resistance • free from halogens and cadmium • very good chemical properties temperature range –50°C ... +90°C continuous, +150°C short-term ATEX approved for: –40°C ... +85°C continuous specifications ATEX directive 94/9/EC (ATEX 95) EN 1127-1, EN 60079-0, -7, -31 approval 1258 II 2G Ex eb IIC II 2D Ex tb IIIC SEV 05 ATEX 0105 compatible with PMA Ex-System, Connectors and system supports colour outer layer: black, inner layer: yellow Three Layer Corrugated Conduit very flexible, medium-duty DB-Nr. 16130-03 27.03.2012/YS 1/3 Drei-Schicht-Wellrohr sehr flexibel, mittelschwer Einsatzbereich • für Anwendungen mit hoher mechanischer Beanspruchung in explosionsgefährdeten Berei- chen der Zonen 1/2 und 21/22 (nach ATEX 137) • für Einsatz bei sehr tiefen Temperaturen Material • Aussenschicht: hochwertiges, speziell formuliertes Polyamid 12 • Mittelschicht: spez. Haftungscompound • Innenschicht: speziell modifiziertes Polyethylen Eigenschaften • elektrostatisch ableitend • für Innen- und Ausseneinsätze • sehr gute UV-Beständigkeit • sehr hohe mechanische Belastbarkeit und Kälteschlagfestigkeit • hohe Abriebfestigkeit • halogen- und cadmiumfrei • sehr gute chemische Eigenschaften Temperaturbereich –50°C ... +90°C kontinuierlich, +150°C kurzzeitig für ATEX-Anwendung: –40°C ... +85°C kontinuierlich Spezifikationen ATEX-Richtlinie 94/9/EG (ATEX 95) EN 1127-1, EN 60079-0, -7, -31 Zulassung 1258 II 2G Ex eb IIC II 2D Ex tb IIIC SEV 05 ATEX 0105 passend zu PMA Ex-System, Verschraubungen und Systemhalter Farbe Aussenschicht: schwarz, Innenschicht: gelb PMA AG (Headquarters) · Aathalstrasse 90 · 8610 Uster · Switzerland · Tel: +41 44 905 61 11 · Fax +41 44 905 61 22 · info@pma.ch · www.pma.ch Dimensions Dimensionen Technical Data Sheet Technisches Datenblatt XESX Index min. max. ductility Biegbarkeit fatigue / reversed bending Dauer- / Biegewechselfestigkeit pressure resistance Druck- / Trittfestigkeit cold temperature performance Kälteeigenschaften weather resistance Witterungseigenschaften Fine profile T Feinprofil T Tight bend radius Enge Biegeradien Coarse profile G Grobprofil G High pull-out strength Hohe Ausreisskräfte Code reference Nr.-Schlüssel X = multi layer Mehrschicht ESX = type Ex Ex-Typ G = coarse profile Grobprofil T = fine profile Feinprofil 17 = nominal width Nennweite outer layer: Aussenschicht: B = colour-black Farbe schwarz inner layer: Innenschicht: Y = colour-yellow Farbe gelb ESX BX YG 17- XESX PMA Ex-System X-Serie order no. conduit size rec. fitting thread dimensions in mm (nom.) weight packing unit black / yellow NW metric d1 d2 stat. R. dyn. R. kg/100 m PU/m Bestell-Nr. Rohrgrösse empf. Verschrau- bungs-Gewinde Dimensionen in mm (nom.) Gewicht Verp.-Einheit schwarz / gelb NW metrisch d1 d2 stat. R. dyn. R. kg/100 m VE/m XESXT-10BY 10 M12 / M16 9.2 12.8 25 65 3.0 50 XESXT-12BY 12 M16 / M20 11.8 15.6 30 70 4.2 50 XESXG-17BY 17 M20 / M25 15.2 21.0 35 85 7.0 50 XESXG-23BY 23 M25 / M32 22.0 28.5 40 110 10.5 50 XESXG-29BY 29 M32 / M40 27.5 34.4 50 130 14.0 50 XESXG-36BY 36 M40 / M50 35.8 42.4 60 180 18.5 30 XESXG-48BY 48 M50 / M63 46.8 54.4 70 220 25.0 30 Our customer service dept. or local distribution partner will be pleased to help you concerning product availability and lead time Unser Kundendienst oder die lokale PMA-Vertretung gibt Ihnen über die Artikelverfügbarkeit und Lieferzeit gerne Auskunft stat. R. = lowest recommended bending radius for static (fixed) installation kleinster empfohlener Biegeradius für statische (feste) Verlegung dyn. R. = lowest recommended bending radius for dynamic (flexible) installation kleinster empfohlener Biegeradius für dynamische (flexible) Verlegung CABLE PROTECTION KABELSCHUTZTECHNIK
  • 2. PMA AG (Headquarters) · Aathalstrasse 90 · 8610 Uster · Switzerland · Tel: +41 44 905 61 11 · Fax +41 44 905 61 22 · info@pma.ch · www.pma.ch Three Layer Corrugated Conduit very flexible, medium-duty DB-Nr. 16130-03 27.03.2012/YS 2/3 Drei-Schicht-Wellrohr sehr flexibel, mittelschwer Technical Data Sheet Technisches Datenblatt XESX PMA Ex-System X-Serie CABLE PROTECTION KABELSCHUTZTECHNIK properties unit value test method according to Eigenschaften Einheit Wert Prüfmethode nach Mechanical properties Mechanische Eigenschaften Impact strength Schlagfestigkeit (+85 °C) J ≥ 7 EN 60079-0 Schlagfestigkeit (–30 °C) J ≥ 7 EN 60079-0 J > 6 PMA DO 9.21-4330 Compression strength Scheiteldruckfestigkeit N > 300 (50 x 50 mm) PMA DO 9.21-4320 N > 600 (100 x 100 mm) Reversed bending stresses Biegewechselfestigkeit cycles > 200‘000 PMA DO 9.21-4420 cycles > 600‘000 PMA DO 9.21-4220 Pull-out resistance conduit/connect. Ausreissfestigkeit Wellrohr/Verschraub.: PMA Ex-System, type IP66 PMA Ex-System, Typ IP66 N > 300 PMA DO 9.21-4610 PMA Ex-System, type IP68 PMA Ex-System, Typ IP68 N > 400 Testing at 23°C, 50% r.h., conduit Prüftemperatur 23°C, 50% r.F., Rohr- nominal width 17, unless otherwise nennweite 17, sofern nicht anders stated angegeben Thermal properties Thermische Eigenschaften General: Allgemein: Continuous application temperature Dauergebrauchstemperatur °C –50 ... +90 PMA DO 9.21-4510 Upper application temperature obere Anwendungstemperatur °C +110 20‘000 h Short-term kurzzeitig °C +150 168 h For ATEX use: für ATEX-Anwendung: Continuous application temperature Dauergebrauchstemperatur °C –40 ... +85 EN 60079-0 Fire safety characteristics Brandschutzeigenschaften Free from halogens and cadmium Halogen- und cadmiumfrei yes / ja DIN 53474 Electrical properties Elektrische Eigenschaften Specific volume resistivity Spezif. Durchgangswiderstand Ω m < 103 DIN IEC 60093 Specific surface resistivity Spezif. Oberflächenwiderstand Ω < 106 DIN IEC 60093 Weathering resistance Witterungsbeständigkeit Weathering (UV/humidity) Bewitterung (UV/Feuchte) very good For black colour für schwarze Farbe sehr gut Chemical properties Chemische Eigenschaften Please refer to catalogue ersichtlich im Katalog PMA Ex-System PMA Ex-System or www.pma.ch oder unter www.pma.ch
  • 3. XESX PMA Ex-System X-Serie PMA AG (Headquarters) · Aathalstrasse 90 · 8610 Uster · Switzerland · Tel: +41 44 905 61 11 · Fax +41 44 905 61 22 · info@pma.ch · www.pma.ch The specifications and instructions for our customers in this document reflect the product engineering level at the time of manufacturing. Please consider the valid data sheet release at a time. For questions please contact the PMA customer service. PMA AG accepts no liability for damages resulting from un- professional installation or application or misuse for a purpose. This disclaimer also includes damages to third parties. It is the customer‘s responsibility to check the delivered products and immediately notify PMA AG of detected faults. It is also the customer‘s responsibility to test the delivered product on its applicability for the intended purpose. PMA AG will accept no liability or responsibility for their products if a product or a PMA system is combined or used together with third-party products, i.e. products from other companies than PMA AG. Jurisdiction in all legal disputes concerning product liability have the courts of the canton of Zurich/Switzerland. Swiss law applies. For more information and the newest data sheet releases go to: www.pma.ch Die in diesem Dokument für unsere Kunden enthaltenen Angaben und Instruktionen entsprechen dem neuesten Stand unserer Technik zum Zeitpunkt der Herstellung des Produktes. Es ist der jeweils gültige Datenblattstand zu berücksichtigen. Bei Fragen wenden Sie sich bitte an den PMA-Kundendienst. Die PMA AG lehnt jede Haftung bei unsachgemässer Montage oder Verwendung sowie Zweckentfrem- dung des Produktes ab. Dieser Haftungsausschluss umfasst auch allfällige Drittschäden. Es obliegt dem Kunden, die gelieferte Ware zu prüfen und allfällig festgestellte Mängel sofort der PMA AG anzuzeigen. Es obliegt ferner dem Kunden, die Ware auf ihre Eignung zwecks einer spezifischen Anwendung zu überprüfen. Die PMA AG lehnt jegliche Haftung für ihre Produkte ab, wenn ein einzelnes Produkt oder ein PMA-System mit Fremdprodukten, d.h. Produkten anderer Unternehmungen kombiniert bzw. ver- wendet wird. Gerichtsstand für Streitigkeiten bezüglich Produkthaftung sind die Gerichte des Kantons Zürich/Schweiz. Es kommt Schweizer Recht zur Anwendung. Ergänzende Informationen und neueste Datenblätter unter: www.pma.ch Three Layer Corrugated Conduit very flexible, medium-duty DB-Nr. 16130-03 27.03.2012/YS 3/3 Drei-Schicht-Wellrohr sehr flexibel, mittelschwer Technical Data Sheet Technisches Datenblatt CABLE PROTECTION KABELSCHUTZTECHNIK properties unit value test method according to Eigenschaften Einheit Wert Prüfmethode nach Environmental properties Umwelteigenschaften RoHS compliant RoHS-konform yes / ja EU Directive 2002/95/EC Content of delivery Lieferumfang Conduit Wellrohr In addition to the national and international standards which consider mainly material properties and general product performance, PMA applies its own internally developed standards when assessing the system suitability of cable protection products. The PMA standards are based on 30 years experience and allow a better assessment of whether a product is practically appropriate for a specific application. Neben internationalen und nationalen Normen, die sich vor allem auf Materialeigenschaften und allgemeine Produkteigenschaften beziehen, wendet PMA ergänzend selbst definierte Werknormen zur Beurteilung der Systemeigenschaften von Kabelschutzprodukten an. Diese erlauben auf der Basis über 30 jähriger Erfahrungen eine bessere Beurteilung der praktischen Eignung eines Produktes für spezifische Anwendungen.