SlideShare ist ein Scribd-Unternehmen logo
1 von 9
Downloaden Sie, um offline zu lesen
International Journal of Engineering Research and Development
e-ISSN: 2278-067X, p-ISSN: 2278-800X, www.ijerd.com
Volume 7, Issue 10 (July 2013), PP. 55-63
55
Thermo-Hydraulic Performance of a Roughened Square Duct
Having Inclined Ribs with a Gap on Two Opposite Walls
S. Gupta1
, A. Chaube2
, P. Verma3
1
Corresponding Author, Department of Mechanical Engineering, Rajiv Gandhi Technological University,
Bhopal-462036 (M.P.), India.
2
Department of Mechanical Engineering, Jabalpur Engineering College, Jabalpur-482011 (M.P.), India.
3
Department of Industrial and Production Engineering, Jabalpur Engineering College, Jabalpur-482011
(M.P.), India.
Abstract:- Experimentation has been carried out to find the influence of a gap provided in ribs on thermo-
hydraulic performance of a square duct roughened with discrete inclined ribs. The two opposite walls of the
square duct are roughened with ribs having attack angle (α) of 450
and a gap on its length. The investigation
has been performed for relative roughness pitch (p/e) of 10, relative roughness height (e/Dh) of 0.060 and
Reynolds number is varied in the range of 5000-40,000. The other rib parameters; relative gap position (d/W)
and relative gap width (g/e) is varied in the range of 1/4 – 2/3(4 steps) and 0.5 – 1.5 (3 steps) respectively. The
comparative study of various cases shows that the ribs with a gap considerably enhance the value of thermo-
hydraulic performance for the range of parameters taken for the present investigation. Presence of inclined ribs
with a gap yields about 2.1-fold enhancements in thermo-hydraulic performance as compared to smooth duct.
The maximum value of thermo-hydraulic performance parameter has been observed for relative gap width
of 1.0 and the relative gap position of 1/3.
Keywords:- Relative gap width, Relative gap position, Reynolds number, Thermo-hydraulic performance.
I. INTRODUCTION
Gas turbines are extensively used for aircraft propulsion, land-based power generation, and industrial
applications. According to the thermodynamics concept, gas turbine performance is improved when the gas
temperature, which exit from combustion chamber, increases. This high gas temperature can melt turbine
blades and cause thermal stress. Thus there is a need to cool the blades to operate without failure.
One of the methods to cool the blades internally is by extracting the air from the compressor of the
engine, which routed through serpentine channels within the blades and extracted the heat from the outsides of
the blades. Internal cooling passages are mounted with ribs on channel walls. These ribs, which are also
known as turbulators, increases the level of mixing by turbulence and disturb the laminar sub-layer, also
increases the surface area for convective heat transfer, thereby enhances the cooling capacity of the passage.
The use of ribs, in addition to enhancing heat transfer coefficient considerably, results in higher frictional
penalty. Therefore, it is essential to optimize the geometrical parameters of the artificial roughness (ribs) in
order to achieve the maximum possible enhancement in heat transfer with minimum frictional penalty. Lewis
[1] proposed a thermo-hydraulic performance parameter known as efficiency parameter ‘η’, which evaluates
the enhancement of heat transfer of a roughened duct compared to that of smooth duct for same pumping
power requirement and is defined as;
 
3/1
)/(
/
or
or
ff
NuNu

Thermo-hydraulic performance (η) having a value higher than unity ensures the fruitfulness of using
enhancement in heat transfer without much friction penalty.
The heat transfer coefficient and friction factor are considerably affected by various geometrical
parameters, such as channel aspect ratio (AR), rib height-to-passage hydraulic diameter (e/Dh), rib attack angle
(α), rib pitch-to-height ratio (p/e), rib shape, discretization of ribs and the manner in which the ribs are
positioned relative to one another [2]. Han et al. [3] investigated the effect of rib shape, angle of attack and
Thermo-Hydraulic Performance Of A Roughened Square Duct Having Inclined…
56
pitch to rib height ratio on heat transfer and friction factor characteristics of a rectangular duct with two
opposite side roughened walls. They observed that the maximum value of heat transfer and friction factor
occurs for square ribs, at a relative roughness pitch of 10 and rib angle of attack of 450
. Han et al. [4] studied
heat transfer and pressure losses with different angle ribs (90°, 60°, 45°, and 30°) in square and rectangular
channels. The higher thermal performance in the square channel was 30° rib angle and the higher thermal
performance in the rectangular channel was 45° rib angle. Johnson et al. [5], Taslim [6], Han [7], and Wagner
[8] studied the heat transfer and friction characteristics in rib-roughened passages with different rib
arrangements. They focused on the effects of the Reynolds number and rib geometry on the heat transfer and
pressure drop in the fully developed region of a uniformly heated square and rectangular channel. All these
studies showed that angled ribs provide better heat transfer enhancement than transverse ribs. Zhang et al. [9]
and Kiml et al. [10] showed that the thermal performance of rib arrangements with an angle of attack of 600
is
better than that with an angle of 450
. Lau et al. [11] observed that the replacement of continuous transverse ribs
by inclined ribs in a square duct results in higher turbulence at the ribbed wall due to interaction of the primary
and secondary flows. Park et al. [12] studied heat transfer and pressure losses with different angle ribs in
square channel and rectangular channels with aspect ratio 1/4, 1/2, 1, 2 and 4. For low aspect ratio, the 45°
and 60° have the highest thermal performance. For square channel, the 60° and 45° have the highest thermal
performance. For large aspect ratio, 30° and 45° have the highest thermal performance. Taslim et al. [13]
study the effect of p/e and e/Dh on the heat transfer and friction losses for 90° sharp angle ribs, and 90° round
angle ribs in square duct. The e/Dh was 0.133, 0.167 and 0.25 and p/e was 5, 7, 8.5, and 10. They found that
relative roughness pitch of 8.5 and 10 has the highest thermal performance.
In the majority of cooling channels, discrete ribs were shown to outperform the continuous angled or
V-shaped ribs [14]. Lau et al. [15] investigated the heat transfer and friction factor characteristics of fully
developed flow in a square duct with transverse and inclined discrete ribs. They reported that a five-piece
discrete rib with 900
angle of attack shows 10-15% higher heat transfer coefficient as compared to the 900
continuous ribs, whereas inclined discrete ribs give 10-20% higher heat transfer than that of the 900
discrete
ribs. Tanda [16] investigated the heat transfer enhancement for one wall-ribbed rectangular channel of AR=5:1
with continuous, 90° and V-broken ribs and found that the enhancement of the 90° broken ribs is around 1.8
times over the continuous ribs. Cho et al. [17] examined the effect of angle of attack and number of discrete
ribs in a square duct and observed that the gap region between the inclined discrete ribs accelerates the flow
and enhances the local turbulence, which will results in an increase in the heat transfer. They also reported
that the inclined rib arrangement with a downstream gap position shows higher enhancement in heat transfer
compared to that of continuous inclined rib arrangement. Aharwal et al. [18] experimentally investigated the
heat transfer enhancement due to a gap in an inclined continuous rib arrangement in rectangular duct of solar
air heater and observed the optimum performance for relative gap width of 1.0 and at relative gap position of
0.25.Thakur et al. [19] performed study on absorber plate of solar air heater duct roughened with inclined
discrete ribs. They reported that the maximum heat transfer enhancement occurs for the relative roughness
pitch of 12, relative gap position of 0.35 and relative roughness height of 0.0498.
The literature review reveals that discrete inclined or V-shaped rib arrangement can yield better
performance as compared to continuous rib arrangement. Only few researchers have been given the
information about the number of discretized parts of ribs in to which it should be broken so as to give the
maximum thermal performance. Some of the researchers given the results of providing gaps in inclined ribs in
leading and trailing edge of the ribs. However, investigations have not been carried out so far to optimize the
gap width between rib elements to form the discrete rib and also to locate the optimum position of this gap,
particularly in case of two opposite rib roughened walls which is used in gas turbine blade internal cooling.
Therefore, present study has been performed to determine the optimum location and width of gap in an
inclined rib to form a discrete rib for maximum thermal performance of a roughened square duct.
II. EXPERIMENTAL PROGRAM
A schematic diagram of the test set-up used in the present study is shown in figure 1. The wooden
square duct has an internal size of 3750 mm x 75 mm x 75 mm, which consists of an entrance section, a test
section and an exit section of length 1500 mm (20Dh), 1500 mm (20Dh) and 750 mm (10Dh) respectively [9].
The entrance unheated duct serves to establish hydro-dynamically fully developed flow at the entrance to the
test duct and unheated exit section is used downstream of the test section in order to reduce the end effect in
the test section. The exit end of the duct is connected to 81 mm internal diameter G. I. pipe provided with a
calibrated orifice plate through a square to circular transition piece. The outside of entire set-up from inlet to
the orifice plate, were covered with 25 mm thick thermocole sheet, so that the heat losses from the test section
can be minimized.
Thermo-Hydraulic Performance Of A Roughened Square Duct Having Inclined…
57
FIG. 1: Schematic diagram of experimental set-up
The entrance and exit sections are made by 50 mm thick polished wooden walls. The square test duct
consists of 6 mm thick heated aluminium plate on its top and bottom walls. The other two walls of test section
are constructed by 50 mm thick polished wood. The ribbed aluminium plates are made by gluing square
aluminium ribs (4.5 mm x 4.5 mm) to the finished aluminium plate surface in a required distribution to serve
as top and bottom ribbed walls of the test section. The plates are heated from outside by means of separate
heaters assembly, thus subjected to uniform heat flux (0-1500 W/m2
) and are insulated with 50 mm thick glass
wool topped with 12 mm thick plywood. A calibrated orifice-meter connected with an inclined U-tube
manometer used to measure the mass flow rate of air through the duct. A control valve is provided in the pipe
line to connect the blower to regulate the flow rate of air. The temperatures of the test plate are measured by 24
copper-constantan calibrated thermocouples, distributed along the length and across the span by drilling about
2 mm diameter holes around 3-4 mm deep at the back side of the plate. Four thermocouples are arranged span
wise in the duct to measure the air temperature at exit of the test section and 2 thermocouples are used at inlet
to the test section, to measure the entry temperature of air. A digital micro-manometer (Fluke-922) is used to
measure the pressure drop across the test section.
Experimental data is collected under steady- state condition for different mass flow rate of air to give
the flow Reynolds number in the range of 5000 – 40,000. The heat flux was set and kept constant for each run
so as to maintain the temperature of roughened plate around 200
C - 300
C above to that of mean bulk air
temperature, to minimize the error.
III. ROUGHNESS GEOMETRY AND RANGE OF PARAMETERS
The dimensionless roughness parameters are determined by rib height (e), rib pitch (p), gap position
(d) and gap width (g). The schematic of the geometry of inclined discrete rib used in the present study is shown
in figure 2. The values of system and operating parameters are selected on the basis of related literature [4, 6,
9, 12, 13, 15, 17, 18, 19] and are given in Table I.
FIG. 2: Schematic of roughness geometry of an inclined rib
Thermo-Hydraulic Performance Of A Roughened Square Duct Having Inclined…
58
Table I: Range of parameters
S.
No.
Parameters Range of parameter
1 Reynolds number, (Re) 5000 - 40000
2 Relative roughness height, (e/Dh) 0.060
3 Relative gap width, (g/e), 0.5, 1, 1.5 (3 steps)
4 Relative gap position, (d/W) 1/4,1/3,1/2 and 2/3 (4 steps)
5 Rib attack angle, (α) 450
6 Relative roughness pitch (p/e) 10
IV. DATA REDUCTION
To determine heat transfer coefficient „h‟, useful heat gain „Qu‟, Nusselt number „Nu‟, Reynolds
number „Re‟ and friction factor „f‟‟, the following procedure is adopted ;
The mass flow rate, m, of air through the duct has been calculated from pressure drop measurement
across the orifice plate.
 
5.0
4
1
..2
.. 









 oa
od
P
ACm (1)
where, Cd is the coefficient of discharge which is determined as 0.610 by calibration.
The pressure drop (ΔP)o across the orifice plate is given by
(ΔP)o = 9.81 X (Δh)o X ρm X sinθ (2)
The heat-transfer coefficient for the heated section was calculated as;
)( fpp
u
TTA
Q
h

 (3)
where, heat transfer rate, Qu to the air is given by
Qu = m Cp (To – Ti) (4)
where Tp and Tf are average temperature values of test plate and fluid respectively. The average value of plate
temperature (Tp) is calculated as a weighted mean of the plate temperature measured at different locations.
The convective heat transfer coefficient is then used to obtain Nusselt number, Nu , as
a
h
k
hD
Nu  (5)
The Reynolds number was determined from the value of velocity of air through the duct, using
equation:
a
haVD
e


R (6)
where,
HW
m
V
a ..
 (7)
The friction factor was determined from the measured values of pressure drop, (ΔP)d across the test
section length, between the two points located 1.2 m apart.
2
4
)(2
VLρ
DP
f
fa
hd
 (8)
where, (ΔP)d is the pressure drop across the duct and is given by
(ΔP)d = 9.81 X (Δh)d X ρm (9)
The uncertainty analysis as proposed by Kline and McClintock [20] was used for the prediction of
uncertainty associated with the experimental results based on the observations of the scatter in the raw data
used in calculating the results. The uncertainties in the calculated values of Reynolds number, Nusselt number
and Friction factor are estimated as ± 1.65 %, ± 1.94 %, ± 3.22 % respectively.
Thermo-Hydraulic Performance Of A Roughened Square Duct Having Inclined…
59
V. VALIDATION OF EXPERIMENTAL DATA
The values of Nusselt number and friction factor determined from the experimental data are compared
with the values obtained with the standard Dittus-Boelter equation (Nuo= 0.023 Re0.8
Pr0.4
) for the Nusselt
number and Blasius equation (fo = 0.079 Re-0.25
) for friction factor [21]. The comparison of the experimental
and predicted values of Nusselt number and friction factor as a function of Reynolds number is shown in figure
3 and in figure 4 respectively. The average deviation between the predicted and experimental values has been
found to be ±3.4 % and ±5.9 % for Nusselt number and friction factor respectively. This shows a good match
between the two values, which ensures the accuracy of the experimental data with the present experimental set-
up.
FIG. 3: Comparison of experimental and predicted values of Nusselt number for smooth duct
FIG. 4: Comparison of experimental and predicted values of friction factor for smooth duct
VI. RESULTS AND DISCUSSION
The effect of flow and roughness parameters on the thermal-hydraulic performance of an artificially
rib-roughened square duct has been investigated and presented in Figs. 5- 9. Fig. 5 to Fig. 8 shows the effect of
relative gap width on thermo-hydraulic performance for different relative gap positions at few selected
Reynolds numbers. The thermo-hydraulic performance of roughened duct considerably increases due to gap in
ribs as compared to smooth duct. As expected, the thermo-hydraulic performance of roughened duct decreases
as the Reynolds number increases due to high turbulence effect at high Reynolds number for all the cases. It is
observed that the maximum value of thermo-hydraulic performance occurs at relative gap width of 1 for all gap
positions and also for all Reynolds numbers. This result conforms the result of Aharwal et. at. [17].The
enhancement in thermo-hydraulic performance varies in the range of about 1.3 to 2.1 times of smooth duct
(without ribs) in the range of flow parameter (Re varies from 5000 to 40000).
Thermo-Hydraulic Performance Of A Roughened Square Duct Having Inclined…
60
FIG. 5: Effect of relative gap width on thermo-hydraulic performance for d/W = 1/4
FIG. 6: Effect of relative gap width on thermo-hydraulic performance for d/W = 1/3
The thermo-hydraulic performance increases with increase in gap width from 0.5 to 1.0 beyond which
it decreases with increase in gap width throughout the range of Reynolds number. This is prompted as by
creating a gap in rib, it promotes local turbulence and flow mixing along the gap flow region while the rib
induced secondary flow is usually maintained in the duct. It may, therefore, reasoned that the widening the gap
width beyond 1 reduces the flow velocities through the gap and hence local turbulence, whereas too small gap
width will not allow sufficient amount of secondary flow of fluid to pass through it and hence the turbulence
level will remain low which ultimately results in low Nusselt number ratio (Nur/Nuo) as compared to g/e =1.
To bring out the effect of relative gap position clearly, the value of thermo-hydraulic performance is
plotted as a function of relative gap position and is shown in Fig.10 at few selected Reynolds number and for
relative gap width of 1.0. It is clear that thermo-hydraulic performance attains a maximum value at relative
gap position of 1/3. It is note that the inclination of rib creates a high heat transfer region at the leading edge
and a low heat transfer region at the trailing edge [22]. The gap in trailing edge region helps in improving the
Nusselt number ratio and is observed till the gap position is about 1/3 of the duct width. The gap at a position
close to duct wall (d/w = 1/4) is not likely to produce similar effect as lateral boundary layer near to the wall
may plays a dominant role. Thus placing the gap closer to the trailing edge side of inclined rib reckons poor
results. Whereas, if, a gap is created near the leading edge (d/w = 2/3) the secondary flow weakens and thus
this gap position does not lead to significant increase in thermo-hydraulic performance.
Thermo-Hydraulic Performance Of A Roughened Square Duct Having Inclined…
61
FIG. 7: Effect of relative gap width on thermo-hydraulic performance for d/W = 1/2
FIG. 8 Effect of relative gap width on thermo-hydraulic performance for d/W = 2/3
FIG. 9: Effect of relative gap position on thermo-hydraulic performance for g/e = 1
Thermo-Hydraulic Performance Of A Roughened Square Duct Having Inclined…
62
VII. CONCLUSION
On the basis of experimental results it is found that by providing gap in the inclined rib, there is
considerable enhancement in thermo-hydraulic performance of a square opposite side artificially roughened
duct. The main findings are:
1. The thermo-hydraulic performance of roughened surface having inclined ribs with a gap yields an
increase of about 2.1 times as compared to that of smooth duct in the range of Reynolds number from
5000 to 40000.
2. The value of thermo-hydraulic performance decreases with the increase in Reynolds number.
3. The relative gap position of 1/3 and the relative gap width of 1 give the highest value of thermo-
hydraulic performance parameter.
NOMENCLATURE
A Area of duct cross section, m2
Ap Area of roughened plate, m2
Apipe cross section area of pipe, m2
AR Channel aspect ratio (W/H)
Cd Coefficient of discharge for orifice meter
Cp Specific heat of air at const. pressure, J/kg K
Dh Channel hydraulic diameter of duct, m
(= 4 W H /2(W+H))
Dp Inside diameter of pipe, m
d/W Relative gap position
e Rib height, m
e/Dh Relative roughness height
f friction factor
fo Friction factor for smooth circular duct
fr Friction factor for roughened duct
fr / fo Friction factor ratio
g/e Relative gap width
H Depth of duct, m
h Convective heat transfer coefficient, W/m2
K
ka Thermal conductivity of air, W/m K
L Test section length, m
Lf Duct length to calculate friction factor, m
L/Dh Test length to hydraulic diameter ratio
m mass flow rate, kg/s
Nu Nusselt number
Nuo Nusselt number for smooth circular duct
Nur Nusselt number for roughened duct
Nur/Nuo Nusselt number ratio
p Rib pitch, m
Pr Prandtl number
(ΔP)d Pressure drop in the test channel, N/m2
(ΔP)o Pressure drop across the orifice plate,
N/m2
p/e Relative roughness pitch
Qu Useful Heat gain, W
Re Reynolds number
Tf Bulk mean air temperature, 0
C or K
Ti Air inlet temperature, 0
C or K
To Air outlet temperature, 0
C or K
Tp Mean plate temperature, 0
C or K
V Velocity of air, m/s
W Width of duct, m
GREEK SYMBOLS
α Rib angle of attack, degree
β Ratio of orifice diameter to pipe diameter
θ Angle of inclination of U-tube manometer
µa Dynamic viscosity of air, N s m-2
ρa Density of air, kg m-3
ρm Density of manometer fluid, kg m-3
REFERENCES
[1] M. J. Lewis, “Optimizing the thermo hydraulic performance of rough surface”, international Journal
of Heat and Mass transfer”, 18, (1975), pp. 1243-1248.
[2] J. C. Han, S. Dutta, and S. V. Ekkad, “Gas Turbine Heat Transfer and Cooling Technology”, Taylor
& Francis, Inc., New York, (2001).
[3] J.C. Han, L.R. Glicksman, and W.M. Rohsenow, “An Investigation of Heat Transfer and Friction for
Rib-Roughened Surfaces,” International Journal of Heat and Mass Transfer, 21, (1978), pp. 1143-
1156.
[4] J.C. Han and J.S. Park, “Developing Heat Transfer in Rectangular Channels with Rib Turbulators,”
International Journal of Heat and Mass Transfer, 31,(1988), pp. 183-195.
[5] B. V. Johnson, J. H. Wagner, G. D. Steuber, and F. C. Yeh, „„Heat Transfer in Rotating Serpentine
Passages With Selected Model Orientations for Smooth or Skewed Trip Walls,‟‟ ASME Paper 93-GT-
305 (1993).
[6] M. E. Taslim, „„An Experimental Investigation of Heat Transfer Coefficients in a Spanwise Rotating
Channel With Two Opposite Rib-Roughened Walls,‟‟ ASME Journal of Turbomachinery, 113,
(1991), pp. 75–82.
[7] J. C. Han, „„Heat Transfer Enhancement in Channels With Turbulence Promoters,‟‟ ASME J. of
Engg. Gas Turbines Power, 106, (1985), pp. 774–781.
Thermo-Hydraulic Performance Of A Roughened Square Duct Having Inclined…
63
[8] J. H. Wagner,„„Heat Transfer in Rotating Serpentine Passages With Trips Normal to the Flow,‟‟
ASME Journal of Turbomachinery, 114, (1992), pp. 847–457.
[9] J.C. Han and Y.M. Zhang, “High Performance Heat Transfer Ducts with Parallel and V-Shaped
Broken Ribs,” International Journal of Heat and Mass Transfer, 35, (1992), pp. 513-523.
[10] R. Kiml, S. Mochizuki, A. Murata „„Effects of rib arrangements on heat transfer and flow behavior in
a rectangular rib roughened passage , Journal of heat transfer, 123,(2001), pp. 675-681.
[11] S.C. Lau, R.D. McMillin, J.C. Han, “Heat Transfer characteristics of turbulent flow in a square
channel with angled rib”, Trans. ASME, Journal of Turbomachinery, 113, (1991), pp 367-374.
[12] J.S. Park, J.C. Han, Y. Huang, S. Ou, “Heat transfer performance comparisons of five different
rectangular channels with parallel angled ribs”, International Journal of Heat Mass Transfer, 35 (11),
(1992), pp. 2891–2903.
[13] M.E. Taslim , and C.M. Wadsworth, "An experimental investigation of rib surface- average Heat
Transfer Coefficient in Rib-Roughened Square Passage", Journal of Turbomachinery, 119(2),(1997),
pp. 381-389.
[14] H.H. Cho, S.J. Wu, and H.J. Kwon, “Local Heat/Mass Transfer Measurements in a Rectangular Duct
with Discrete Ribs,” ASME Journal of Turbomachinery, 122 (2000), pp. 579-586.
[15] S.C. Lau, R.D. McMillin, J.C. Han, “Turbulent heat transfer and friction in a square channel with
discrete rib turbulators”, Trans ASME, Journal of Turbomachinery,113, (1991), pp. 360-366,.
[16] G. Tanda, “Heat transfer in rectangular channel with transverse and V-shaped broken ribs”, Int.
Journal of Heat and Mass Transfer, 47, (2004), pp. 229–243.
[17] H.H. Cho, Y.Y. Kim, D.H. Rhee, S.Y. Lee, S.J. Wu, “The effect of gap position in discrete ribs on
local heat/mass transfer in a square duct”, Journal of Enhanced Heat Transfer, 10 (3), (2003),
pp. 287-300.
[18] K. R. Aharwal, B. K. Gandhi, J. S. Saini, “Experimental investigation on heat-transfer enhancement
due to a gap in an inclined continuous rib arrangement in a rectangular duct of solar air heater”,
Journal of Renewable Energy, 33 (2008), pp. 585-596.
[19] S. K. Thakur, V Mittal, N. S. Thakur, and A. Kumar, “Heat Transfer and Friction Factor Correlations
for rectangular Solar Air Heater Duct Having 60° Inclined Continuous Discrete Rib Arrangement”,
British Journal of Applied Science & Technology,1(3), (2011), pp. 67-93.
[20] J. P. Holman, Experimental methods for engineers, Tata Mcgraw Hills, New Delhi, 2004.
[21] M. S. Bhatti, R. K. shah, “Turbulent and transition flow convective heat transfer, Handbook of
Single-phase Convective Heat Transfer, wiley, New York, 1987.
[22] J. C. Han, W. L. Fu, L. M. Wright, “ Thermal performance of angled, V-shaped and W-shaped rib
tabulators in rotating rectangular cooling channel”, Trans. ASME, Journal of Turbomachinery,
(2004),126, pp. 604-614.

Weitere ähnliche Inhalte

Was ist angesagt?

Was ist angesagt? (17)

Improved Thermal Performance of Solar Air Heater Using V-Rib with Symmetrical...
Improved Thermal Performance of Solar Air Heater Using V-Rib with Symmetrical...Improved Thermal Performance of Solar Air Heater Using V-Rib with Symmetrical...
Improved Thermal Performance of Solar Air Heater Using V-Rib with Symmetrical...
 
Ijetr042191
Ijetr042191Ijetr042191
Ijetr042191
 
A Review- Comparative Study of Thermal and Hydrostatic Performance Analysis O...
A Review- Comparative Study of Thermal and Hydrostatic Performance Analysis O...A Review- Comparative Study of Thermal and Hydrostatic Performance Analysis O...
A Review- Comparative Study of Thermal and Hydrostatic Performance Analysis O...
 
At4301239243
At4301239243At4301239243
At4301239243
 
An Experimental Research on Heat Transfer Enhancement of a Circular Tube with...
An Experimental Research on Heat Transfer Enhancement of a Circular Tube with...An Experimental Research on Heat Transfer Enhancement of a Circular Tube with...
An Experimental Research on Heat Transfer Enhancement of a Circular Tube with...
 
The Effect of insertion of different geometries on heat transfer performance ...
The Effect of insertion of different geometries on heat transfer performance ...The Effect of insertion of different geometries on heat transfer performance ...
The Effect of insertion of different geometries on heat transfer performance ...
 
15. experimental investigation of heat transfer characteristics of
15. experimental investigation of heat transfer characteristics of15. experimental investigation of heat transfer characteristics of
15. experimental investigation of heat transfer characteristics of
 
IRJET- Numerical Analysis for Effect of Different Length Combination of Turbu...
IRJET- Numerical Analysis for Effect of Different Length Combination of Turbu...IRJET- Numerical Analysis for Effect of Different Length Combination of Turbu...
IRJET- Numerical Analysis for Effect of Different Length Combination of Turbu...
 
EFFECT OF BAFFLES GEOMETRY ON HEAT TRANSFER ENHANCEMENT INSIDE CORRUGATED DUCT
EFFECT OF BAFFLES GEOMETRY ON HEAT TRANSFER ENHANCEMENT INSIDE CORRUGATED DUCTEFFECT OF BAFFLES GEOMETRY ON HEAT TRANSFER ENHANCEMENT INSIDE CORRUGATED DUCT
EFFECT OF BAFFLES GEOMETRY ON HEAT TRANSFER ENHANCEMENT INSIDE CORRUGATED DUCT
 
Assessment of Performance Characteristic of Solar Air Heater with Assorted Ge...
Assessment of Performance Characteristic of Solar Air Heater with Assorted Ge...Assessment of Performance Characteristic of Solar Air Heater with Assorted Ge...
Assessment of Performance Characteristic of Solar Air Heater with Assorted Ge...
 
EXPERIMENTATION ON COPPER TUBE WITH INTERNAL THREADING FOR A HEAT EXCHANGER P...
EXPERIMENTATION ON COPPER TUBE WITH INTERNAL THREADING FOR A HEAT EXCHANGER P...EXPERIMENTATION ON COPPER TUBE WITH INTERNAL THREADING FOR A HEAT EXCHANGER P...
EXPERIMENTATION ON COPPER TUBE WITH INTERNAL THREADING FOR A HEAT EXCHANGER P...
 
IRJET- Experimental Investigation of Enhancement of Convective Heat Trans...
IRJET-  	  Experimental Investigation of Enhancement of Convective Heat Trans...IRJET-  	  Experimental Investigation of Enhancement of Convective Heat Trans...
IRJET- Experimental Investigation of Enhancement of Convective Heat Trans...
 
30120140507001
3012014050700130120140507001
30120140507001
 
Review of Convective Heat Transfer from Plate Fins Under Natural and Mixed Co...
Review of Convective Heat Transfer from Plate Fins Under Natural and Mixed Co...Review of Convective Heat Transfer from Plate Fins Under Natural and Mixed Co...
Review of Convective Heat Transfer from Plate Fins Under Natural and Mixed Co...
 
IRJET- Experimental Analysis of Convective Heat Transfer Augmentation of Bi-M...
IRJET- Experimental Analysis of Convective Heat Transfer Augmentation of Bi-M...IRJET- Experimental Analysis of Convective Heat Transfer Augmentation of Bi-M...
IRJET- Experimental Analysis of Convective Heat Transfer Augmentation of Bi-M...
 
Thermo hydraulics performance of turbulent flow heat transfer through square ...
Thermo hydraulics performance of turbulent flow heat transfer through square ...Thermo hydraulics performance of turbulent flow heat transfer through square ...
Thermo hydraulics performance of turbulent flow heat transfer through square ...
 
Thermo hydraulics performance of turbulent flow heat transfer through square ...
Thermo hydraulics performance of turbulent flow heat transfer through square ...Thermo hydraulics performance of turbulent flow heat transfer through square ...
Thermo hydraulics performance of turbulent flow heat transfer through square ...
 

Andere mochten auch

Tiffin windows 888 778 0212
Tiffin windows 888 778 0212Tiffin windows 888 778 0212
Tiffin windows 888 778 0212
hansons0588
 
hidden corganic collection completa con precios
hidden corganic collection completa con precioshidden corganic collection completa con precios
hidden corganic collection completa con precios
Desireé Hdz. Ibinarriaga
 
Daily mcx newsletter 10 july 2013
Daily mcx newsletter 10 july 2013Daily mcx newsletter 10 july 2013
Daily mcx newsletter 10 july 2013
Richa Sharma
 
Trotwood siding 888 778 0212
Trotwood   siding 888 778 0212Trotwood   siding 888 778 0212
Trotwood siding 888 778 0212
hansons0588
 
Waverly siding 888 778 0212
Waverly siding 888 778 0212Waverly siding 888 778 0212
Waverly siding 888 778 0212
hansons0588
 
Perkun mieszkanie
Perkun mieszkaniePerkun mieszkanie
Perkun mieszkanie
Grimgor
 
Wayne siding 888 778 0212
Wayne siding 888 778 0212Wayne siding 888 778 0212
Wayne siding 888 778 0212
hansons0588
 

Andere mochten auch (20)

New Doc 2_4
New Doc 2_4New Doc 2_4
New Doc 2_4
 
Tiffin windows 888 778 0212
Tiffin windows 888 778 0212Tiffin windows 888 778 0212
Tiffin windows 888 778 0212
 
20111007_Atti_Convegno
20111007_Atti_Convegno20111007_Atti_Convegno
20111007_Atti_Convegno
 
hidden corganic collection completa con precios
hidden corganic collection completa con precioshidden corganic collection completa con precios
hidden corganic collection completa con precios
 
Daily mcx newsletter 10 july 2013
Daily mcx newsletter 10 july 2013Daily mcx newsletter 10 july 2013
Daily mcx newsletter 10 july 2013
 
Presentation In door video vertical in Chisinau
Presentation In door video vertical in ChisinauPresentation In door video vertical in Chisinau
Presentation In door video vertical in Chisinau
 
Ramathuthu_pfarelo
Ramathuthu_pfareloRamathuthu_pfarelo
Ramathuthu_pfarelo
 
Trotwood siding 888 778 0212
Trotwood   siding 888 778 0212Trotwood   siding 888 778 0212
Trotwood siding 888 778 0212
 
FAIS exam
FAIS examFAIS exam
FAIS exam
 
Economics major
Economics majorEconomics major
Economics major
 
Waverly siding 888 778 0212
Waverly siding 888 778 0212Waverly siding 888 778 0212
Waverly siding 888 778 0212
 
Report: A Model For Remote Parental Control System Using Smartphones
Report: A Model For Remote Parental Control System Using SmartphonesReport: A Model For Remote Parental Control System Using Smartphones
Report: A Model For Remote Parental Control System Using Smartphones
 
Elmwood Quarterly Insights July, 2013
Elmwood Quarterly Insights July, 2013Elmwood Quarterly Insights July, 2013
Elmwood Quarterly Insights July, 2013
 
8d5eb957b9390c513b4e073deb50027f
8d5eb957b9390c513b4e073deb50027f8d5eb957b9390c513b4e073deb50027f
8d5eb957b9390c513b4e073deb50027f
 
Perkun mieszkanie
Perkun mieszkaniePerkun mieszkanie
Perkun mieszkanie
 
68c9bebd68a903dfb244a706c88c9dd6
68c9bebd68a903dfb244a706c88c9dd668c9bebd68a903dfb244a706c88c9dd6
68c9bebd68a903dfb244a706c88c9dd6
 
ไทย 50
ไทย 50ไทย 50
ไทย 50
 
Sanom.at – yhteisöllinen paikallismedia jokaiselle kaupunginosalle ja kylälle
Sanom.at – yhteisöllinen paikallismedia jokaiselle kaupunginosalle ja kylälleSanom.at – yhteisöllinen paikallismedia jokaiselle kaupunginosalle ja kylälle
Sanom.at – yhteisöllinen paikallismedia jokaiselle kaupunginosalle ja kylälle
 
Wayne siding 888 778 0212
Wayne siding 888 778 0212Wayne siding 888 778 0212
Wayne siding 888 778 0212
 
Presentation In door Mediabox (cleaning shoes) in Chisinau
Presentation In door Mediabox (cleaning shoes) in ChisinauPresentation In door Mediabox (cleaning shoes) in Chisinau
Presentation In door Mediabox (cleaning shoes) in Chisinau
 

Ähnlich wie International Journal of Engineering Research and Development (IJERD)

Assessment of thermo-hydraulic performance of inward dimpled tubes with varia...
Assessment of thermo-hydraulic performance of inward dimpled tubes with varia...Assessment of thermo-hydraulic performance of inward dimpled tubes with varia...
Assessment of thermo-hydraulic performance of inward dimpled tubes with varia...
CFD LAB
 
A Detailed Review on Artificial Roughness Geometries for Optimizing Thermo-Hy...
A Detailed Review on Artificial Roughness Geometries for Optimizing Thermo-Hy...A Detailed Review on Artificial Roughness Geometries for Optimizing Thermo-Hy...
A Detailed Review on Artificial Roughness Geometries for Optimizing Thermo-Hy...
IJMER
 

Ähnlich wie International Journal of Engineering Research and Development (IJERD) (20)

ENHANCEMENT OF HEAT TRANSFER IN SHELL AND TUBE HEAT EXCHANGER WITH TABULATOR ...
ENHANCEMENT OF HEAT TRANSFER IN SHELL AND TUBE HEAT EXCHANGER WITH TABULATOR ...ENHANCEMENT OF HEAT TRANSFER IN SHELL AND TUBE HEAT EXCHANGER WITH TABULATOR ...
ENHANCEMENT OF HEAT TRANSFER IN SHELL AND TUBE HEAT EXCHANGER WITH TABULATOR ...
 
Heat Transfer and Friction Factor Characteristics in a Discrete Rib Roughened...
Heat Transfer and Friction Factor Characteristics in a Discrete Rib Roughened...Heat Transfer and Friction Factor Characteristics in a Discrete Rib Roughened...
Heat Transfer and Friction Factor Characteristics in a Discrete Rib Roughened...
 
Performance evaluations of two pass solar air heater using 60⁰ inclinedv-sh...
Performance evaluations of two pass solar air heater using 60⁰ inclinedv-sh...Performance evaluations of two pass solar air heater using 60⁰ inclinedv-sh...
Performance evaluations of two pass solar air heater using 60⁰ inclinedv-sh...
 
30120140507001
3012014050700130120140507001
30120140507001
 
THERMO HYDRAULICS PERFORMANCE OF TURBULENT FLOW HEAT TRANSFER THROUGH SQUARE ...
THERMO HYDRAULICS PERFORMANCE OF TURBULENT FLOW HEAT TRANSFER THROUGH SQUARE ...THERMO HYDRAULICS PERFORMANCE OF TURBULENT FLOW HEAT TRANSFER THROUGH SQUARE ...
THERMO HYDRAULICS PERFORMANCE OF TURBULENT FLOW HEAT TRANSFER THROUGH SQUARE ...
 
Experimental Analysis Of Heat Transfer From Square Perforated Fins In Stagger...
Experimental Analysis Of Heat Transfer From Square Perforated Fins In Stagger...Experimental Analysis Of Heat Transfer From Square Perforated Fins In Stagger...
Experimental Analysis Of Heat Transfer From Square Perforated Fins In Stagger...
 
Assessment of thermo-hydraulic performance of inward dimpled tubes with varia...
Assessment of thermo-hydraulic performance of inward dimpled tubes with varia...Assessment of thermo-hydraulic performance of inward dimpled tubes with varia...
Assessment of thermo-hydraulic performance of inward dimpled tubes with varia...
 
A Detailed Review on Artificial Roughness Geometries for Optimizing Thermo-Hy...
A Detailed Review on Artificial Roughness Geometries for Optimizing Thermo-Hy...A Detailed Review on Artificial Roughness Geometries for Optimizing Thermo-Hy...
A Detailed Review on Artificial Roughness Geometries for Optimizing Thermo-Hy...
 
Comparison of Shell and Tube Heat Exchanger using Theoretical Methods, HTRI, ...
Comparison of Shell and Tube Heat Exchanger using Theoretical Methods, HTRI, ...Comparison of Shell and Tube Heat Exchanger using Theoretical Methods, HTRI, ...
Comparison of Shell and Tube Heat Exchanger using Theoretical Methods, HTRI, ...
 
Natural convection heat transfer in inclined open annulus passege heated from...
Natural convection heat transfer in inclined open annulus passege heated from...Natural convection heat transfer in inclined open annulus passege heated from...
Natural convection heat transfer in inclined open annulus passege heated from...
 
Ic36140914013
Ic36140914013Ic36140914013
Ic36140914013
 
Experimental Investigation of Heat Transfer through Rectangular and Trapezoid...
Experimental Investigation of Heat Transfer through Rectangular and Trapezoid...Experimental Investigation of Heat Transfer through Rectangular and Trapezoid...
Experimental Investigation of Heat Transfer through Rectangular and Trapezoid...
 
PERFORMANCE ENHANCEMENT OF HEAT EXCHANGERS USING VORTEX FLAPS
PERFORMANCE ENHANCEMENT OF HEAT EXCHANGERS USING VORTEX FLAPSPERFORMANCE ENHANCEMENT OF HEAT EXCHANGERS USING VORTEX FLAPS
PERFORMANCE ENHANCEMENT OF HEAT EXCHANGERS USING VORTEX FLAPS
 
The Effect of insertion of different geometries on heat transfer performance ...
The Effect of insertion of different geometries on heat transfer performance ...The Effect of insertion of different geometries on heat transfer performance ...
The Effect of insertion of different geometries on heat transfer performance ...
 
Performance Evaluation of Plate-Fin-And Tube Heat Exchanger with Wavy Fins- A...
Performance Evaluation of Plate-Fin-And Tube Heat Exchanger with Wavy Fins- A...Performance Evaluation of Plate-Fin-And Tube Heat Exchanger with Wavy Fins- A...
Performance Evaluation of Plate-Fin-And Tube Heat Exchanger with Wavy Fins- A...
 
Natural convection heat transfer inside inclined open cylinder
Natural convection heat transfer inside inclined open cylinderNatural convection heat transfer inside inclined open cylinder
Natural convection heat transfer inside inclined open cylinder
 
Review Over The Effects Of Baffle Orientation And Shape Factor Over Pressure ...
Review Over The Effects Of Baffle Orientation And Shape Factor Over Pressure ...Review Over The Effects Of Baffle Orientation And Shape Factor Over Pressure ...
Review Over The Effects Of Baffle Orientation And Shape Factor Over Pressure ...
 
IRJET- Experiment Investigation of Heat Transfer Rate of Fins with Blind Hole...
IRJET- Experiment Investigation of Heat Transfer Rate of Fins with Blind Hole...IRJET- Experiment Investigation of Heat Transfer Rate of Fins with Blind Hole...
IRJET- Experiment Investigation of Heat Transfer Rate of Fins with Blind Hole...
 
HEAT TRANSFER AUGMENTATION IN A PLATE-FIN HEAT EXCHANGER: A REVIEW
  HEAT TRANSFER AUGMENTATION IN A PLATE-FIN HEAT EXCHANGER: A REVIEW  HEAT TRANSFER AUGMENTATION IN A PLATE-FIN HEAT EXCHANGER: A REVIEW
HEAT TRANSFER AUGMENTATION IN A PLATE-FIN HEAT EXCHANGER: A REVIEW
 
NUMERICAL INVESTIGATION OF AUTOMOTIVE RADIATOR LOUVERED FIN COMPACT HEAT EXCH...
NUMERICAL INVESTIGATION OF AUTOMOTIVE RADIATOR LOUVERED FIN COMPACT HEAT EXCH...NUMERICAL INVESTIGATION OF AUTOMOTIVE RADIATOR LOUVERED FIN COMPACT HEAT EXCH...
NUMERICAL INVESTIGATION OF AUTOMOTIVE RADIATOR LOUVERED FIN COMPACT HEAT EXCH...
 

Mehr von IJERD Editor

A Novel Method for Prevention of Bandwidth Distributed Denial of Service Attacks
A Novel Method for Prevention of Bandwidth Distributed Denial of Service AttacksA Novel Method for Prevention of Bandwidth Distributed Denial of Service Attacks
A Novel Method for Prevention of Bandwidth Distributed Denial of Service Attacks
IJERD Editor
 
Gold prospecting using Remote Sensing ‘A case study of Sudan’
Gold prospecting using Remote Sensing ‘A case study of Sudan’Gold prospecting using Remote Sensing ‘A case study of Sudan’
Gold prospecting using Remote Sensing ‘A case study of Sudan’
IJERD Editor
 
Gesture Gaming on the World Wide Web Using an Ordinary Web Camera
Gesture Gaming on the World Wide Web Using an Ordinary Web CameraGesture Gaming on the World Wide Web Using an Ordinary Web Camera
Gesture Gaming on the World Wide Web Using an Ordinary Web Camera
IJERD Editor
 
Hardware Analysis of Resonant Frequency Converter Using Isolated Circuits And...
Hardware Analysis of Resonant Frequency Converter Using Isolated Circuits And...Hardware Analysis of Resonant Frequency Converter Using Isolated Circuits And...
Hardware Analysis of Resonant Frequency Converter Using Isolated Circuits And...
IJERD Editor
 
Simulated Analysis of Resonant Frequency Converter Using Different Tank Circu...
Simulated Analysis of Resonant Frequency Converter Using Different Tank Circu...Simulated Analysis of Resonant Frequency Converter Using Different Tank Circu...
Simulated Analysis of Resonant Frequency Converter Using Different Tank Circu...
IJERD Editor
 

Mehr von IJERD Editor (20)

A Novel Method for Prevention of Bandwidth Distributed Denial of Service Attacks
A Novel Method for Prevention of Bandwidth Distributed Denial of Service AttacksA Novel Method for Prevention of Bandwidth Distributed Denial of Service Attacks
A Novel Method for Prevention of Bandwidth Distributed Denial of Service Attacks
 
MEMS MICROPHONE INTERFACE
MEMS MICROPHONE INTERFACEMEMS MICROPHONE INTERFACE
MEMS MICROPHONE INTERFACE
 
Influence of tensile behaviour of slab on the structural Behaviour of shear c...
Influence of tensile behaviour of slab on the structural Behaviour of shear c...Influence of tensile behaviour of slab on the structural Behaviour of shear c...
Influence of tensile behaviour of slab on the structural Behaviour of shear c...
 
Gold prospecting using Remote Sensing ‘A case study of Sudan’
Gold prospecting using Remote Sensing ‘A case study of Sudan’Gold prospecting using Remote Sensing ‘A case study of Sudan’
Gold prospecting using Remote Sensing ‘A case study of Sudan’
 
Reducing Corrosion Rate by Welding Design
Reducing Corrosion Rate by Welding DesignReducing Corrosion Rate by Welding Design
Reducing Corrosion Rate by Welding Design
 
Router 1X3 – RTL Design and Verification
Router 1X3 – RTL Design and VerificationRouter 1X3 – RTL Design and Verification
Router 1X3 – RTL Design and Verification
 
Active Power Exchange in Distributed Power-Flow Controller (DPFC) At Third Ha...
Active Power Exchange in Distributed Power-Flow Controller (DPFC) At Third Ha...Active Power Exchange in Distributed Power-Flow Controller (DPFC) At Third Ha...
Active Power Exchange in Distributed Power-Flow Controller (DPFC) At Third Ha...
 
Mitigation of Voltage Sag/Swell with Fuzzy Control Reduced Rating DVR
Mitigation of Voltage Sag/Swell with Fuzzy Control Reduced Rating DVRMitigation of Voltage Sag/Swell with Fuzzy Control Reduced Rating DVR
Mitigation of Voltage Sag/Swell with Fuzzy Control Reduced Rating DVR
 
Study on the Fused Deposition Modelling In Additive Manufacturing
Study on the Fused Deposition Modelling In Additive ManufacturingStudy on the Fused Deposition Modelling In Additive Manufacturing
Study on the Fused Deposition Modelling In Additive Manufacturing
 
Spyware triggering system by particular string value
Spyware triggering system by particular string valueSpyware triggering system by particular string value
Spyware triggering system by particular string value
 
A Blind Steganalysis on JPEG Gray Level Image Based on Statistical Features a...
A Blind Steganalysis on JPEG Gray Level Image Based on Statistical Features a...A Blind Steganalysis on JPEG Gray Level Image Based on Statistical Features a...
A Blind Steganalysis on JPEG Gray Level Image Based on Statistical Features a...
 
Secure Image Transmission for Cloud Storage System Using Hybrid Scheme
Secure Image Transmission for Cloud Storage System Using Hybrid SchemeSecure Image Transmission for Cloud Storage System Using Hybrid Scheme
Secure Image Transmission for Cloud Storage System Using Hybrid Scheme
 
Application of Buckley-Leverett Equation in Modeling the Radius of Invasion i...
Application of Buckley-Leverett Equation in Modeling the Radius of Invasion i...Application of Buckley-Leverett Equation in Modeling the Radius of Invasion i...
Application of Buckley-Leverett Equation in Modeling the Radius of Invasion i...
 
Gesture Gaming on the World Wide Web Using an Ordinary Web Camera
Gesture Gaming on the World Wide Web Using an Ordinary Web CameraGesture Gaming on the World Wide Web Using an Ordinary Web Camera
Gesture Gaming on the World Wide Web Using an Ordinary Web Camera
 
Hardware Analysis of Resonant Frequency Converter Using Isolated Circuits And...
Hardware Analysis of Resonant Frequency Converter Using Isolated Circuits And...Hardware Analysis of Resonant Frequency Converter Using Isolated Circuits And...
Hardware Analysis of Resonant Frequency Converter Using Isolated Circuits And...
 
Simulated Analysis of Resonant Frequency Converter Using Different Tank Circu...
Simulated Analysis of Resonant Frequency Converter Using Different Tank Circu...Simulated Analysis of Resonant Frequency Converter Using Different Tank Circu...
Simulated Analysis of Resonant Frequency Converter Using Different Tank Circu...
 
Moon-bounce: A Boon for VHF Dxing
Moon-bounce: A Boon for VHF DxingMoon-bounce: A Boon for VHF Dxing
Moon-bounce: A Boon for VHF Dxing
 
“MS-Extractor: An Innovative Approach to Extract Microsatellites on „Y‟ Chrom...
“MS-Extractor: An Innovative Approach to Extract Microsatellites on „Y‟ Chrom...“MS-Extractor: An Innovative Approach to Extract Microsatellites on „Y‟ Chrom...
“MS-Extractor: An Innovative Approach to Extract Microsatellites on „Y‟ Chrom...
 
Importance of Measurements in Smart Grid
Importance of Measurements in Smart GridImportance of Measurements in Smart Grid
Importance of Measurements in Smart Grid
 
Study of Macro level Properties of SCC using GGBS and Lime stone powder
Study of Macro level Properties of SCC using GGBS and Lime stone powderStudy of Macro level Properties of SCC using GGBS and Lime stone powder
Study of Macro level Properties of SCC using GGBS and Lime stone powder
 

Kürzlich hochgeladen

+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
?#DUbAI#??##{{(☎️+971_581248768%)**%*]'#abortion pills for sale in dubai@
 

Kürzlich hochgeladen (20)

Top 5 Benefits OF Using Muvi Live Paywall For Live Streams
Top 5 Benefits OF Using Muvi Live Paywall For Live StreamsTop 5 Benefits OF Using Muvi Live Paywall For Live Streams
Top 5 Benefits OF Using Muvi Live Paywall For Live Streams
 
The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024
 
How to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerHow to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected Worker
 
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
 
🐬 The future of MySQL is Postgres 🐘
🐬  The future of MySQL is Postgres   🐘🐬  The future of MySQL is Postgres   🐘
🐬 The future of MySQL is Postgres 🐘
 
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
 
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...
Apidays New York 2024 - The Good, the Bad and the Governed by David O'Neill, ...
 
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
 
TrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
TrustArc Webinar - Unlock the Power of AI-Driven Data DiscoveryTrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
TrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
 
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
 
presentation ICT roal in 21st century education
presentation ICT roal in 21st century educationpresentation ICT roal in 21st century education
presentation ICT roal in 21st century education
 
Top 10 Most Downloaded Games on Play Store in 2024
Top 10 Most Downloaded Games on Play Store in 2024Top 10 Most Downloaded Games on Play Store in 2024
Top 10 Most Downloaded Games on Play Store in 2024
 
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot TakeoffStrategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
 
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
 
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost SavingRepurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
 
AWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of TerraformAWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of Terraform
 
Exploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone ProcessorsExploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone Processors
 
Apidays New York 2024 - The value of a flexible API Management solution for O...
Apidays New York 2024 - The value of a flexible API Management solution for O...Apidays New York 2024 - The value of a flexible API Management solution for O...
Apidays New York 2024 - The value of a flexible API Management solution for O...
 
Data Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt RobisonData Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt Robison
 
Real Time Object Detection Using Open CV
Real Time Object Detection Using Open CVReal Time Object Detection Using Open CV
Real Time Object Detection Using Open CV
 

International Journal of Engineering Research and Development (IJERD)

  • 1. International Journal of Engineering Research and Development e-ISSN: 2278-067X, p-ISSN: 2278-800X, www.ijerd.com Volume 7, Issue 10 (July 2013), PP. 55-63 55 Thermo-Hydraulic Performance of a Roughened Square Duct Having Inclined Ribs with a Gap on Two Opposite Walls S. Gupta1 , A. Chaube2 , P. Verma3 1 Corresponding Author, Department of Mechanical Engineering, Rajiv Gandhi Technological University, Bhopal-462036 (M.P.), India. 2 Department of Mechanical Engineering, Jabalpur Engineering College, Jabalpur-482011 (M.P.), India. 3 Department of Industrial and Production Engineering, Jabalpur Engineering College, Jabalpur-482011 (M.P.), India. Abstract:- Experimentation has been carried out to find the influence of a gap provided in ribs on thermo- hydraulic performance of a square duct roughened with discrete inclined ribs. The two opposite walls of the square duct are roughened with ribs having attack angle (α) of 450 and a gap on its length. The investigation has been performed for relative roughness pitch (p/e) of 10, relative roughness height (e/Dh) of 0.060 and Reynolds number is varied in the range of 5000-40,000. The other rib parameters; relative gap position (d/W) and relative gap width (g/e) is varied in the range of 1/4 – 2/3(4 steps) and 0.5 – 1.5 (3 steps) respectively. The comparative study of various cases shows that the ribs with a gap considerably enhance the value of thermo- hydraulic performance for the range of parameters taken for the present investigation. Presence of inclined ribs with a gap yields about 2.1-fold enhancements in thermo-hydraulic performance as compared to smooth duct. The maximum value of thermo-hydraulic performance parameter has been observed for relative gap width of 1.0 and the relative gap position of 1/3. Keywords:- Relative gap width, Relative gap position, Reynolds number, Thermo-hydraulic performance. I. INTRODUCTION Gas turbines are extensively used for aircraft propulsion, land-based power generation, and industrial applications. According to the thermodynamics concept, gas turbine performance is improved when the gas temperature, which exit from combustion chamber, increases. This high gas temperature can melt turbine blades and cause thermal stress. Thus there is a need to cool the blades to operate without failure. One of the methods to cool the blades internally is by extracting the air from the compressor of the engine, which routed through serpentine channels within the blades and extracted the heat from the outsides of the blades. Internal cooling passages are mounted with ribs on channel walls. These ribs, which are also known as turbulators, increases the level of mixing by turbulence and disturb the laminar sub-layer, also increases the surface area for convective heat transfer, thereby enhances the cooling capacity of the passage. The use of ribs, in addition to enhancing heat transfer coefficient considerably, results in higher frictional penalty. Therefore, it is essential to optimize the geometrical parameters of the artificial roughness (ribs) in order to achieve the maximum possible enhancement in heat transfer with minimum frictional penalty. Lewis [1] proposed a thermo-hydraulic performance parameter known as efficiency parameter ‘η’, which evaluates the enhancement of heat transfer of a roughened duct compared to that of smooth duct for same pumping power requirement and is defined as;   3/1 )/( / or or ff NuNu  Thermo-hydraulic performance (η) having a value higher than unity ensures the fruitfulness of using enhancement in heat transfer without much friction penalty. The heat transfer coefficient and friction factor are considerably affected by various geometrical parameters, such as channel aspect ratio (AR), rib height-to-passage hydraulic diameter (e/Dh), rib attack angle (α), rib pitch-to-height ratio (p/e), rib shape, discretization of ribs and the manner in which the ribs are positioned relative to one another [2]. Han et al. [3] investigated the effect of rib shape, angle of attack and
  • 2. Thermo-Hydraulic Performance Of A Roughened Square Duct Having Inclined… 56 pitch to rib height ratio on heat transfer and friction factor characteristics of a rectangular duct with two opposite side roughened walls. They observed that the maximum value of heat transfer and friction factor occurs for square ribs, at a relative roughness pitch of 10 and rib angle of attack of 450 . Han et al. [4] studied heat transfer and pressure losses with different angle ribs (90°, 60°, 45°, and 30°) in square and rectangular channels. The higher thermal performance in the square channel was 30° rib angle and the higher thermal performance in the rectangular channel was 45° rib angle. Johnson et al. [5], Taslim [6], Han [7], and Wagner [8] studied the heat transfer and friction characteristics in rib-roughened passages with different rib arrangements. They focused on the effects of the Reynolds number and rib geometry on the heat transfer and pressure drop in the fully developed region of a uniformly heated square and rectangular channel. All these studies showed that angled ribs provide better heat transfer enhancement than transverse ribs. Zhang et al. [9] and Kiml et al. [10] showed that the thermal performance of rib arrangements with an angle of attack of 600 is better than that with an angle of 450 . Lau et al. [11] observed that the replacement of continuous transverse ribs by inclined ribs in a square duct results in higher turbulence at the ribbed wall due to interaction of the primary and secondary flows. Park et al. [12] studied heat transfer and pressure losses with different angle ribs in square channel and rectangular channels with aspect ratio 1/4, 1/2, 1, 2 and 4. For low aspect ratio, the 45° and 60° have the highest thermal performance. For square channel, the 60° and 45° have the highest thermal performance. For large aspect ratio, 30° and 45° have the highest thermal performance. Taslim et al. [13] study the effect of p/e and e/Dh on the heat transfer and friction losses for 90° sharp angle ribs, and 90° round angle ribs in square duct. The e/Dh was 0.133, 0.167 and 0.25 and p/e was 5, 7, 8.5, and 10. They found that relative roughness pitch of 8.5 and 10 has the highest thermal performance. In the majority of cooling channels, discrete ribs were shown to outperform the continuous angled or V-shaped ribs [14]. Lau et al. [15] investigated the heat transfer and friction factor characteristics of fully developed flow in a square duct with transverse and inclined discrete ribs. They reported that a five-piece discrete rib with 900 angle of attack shows 10-15% higher heat transfer coefficient as compared to the 900 continuous ribs, whereas inclined discrete ribs give 10-20% higher heat transfer than that of the 900 discrete ribs. Tanda [16] investigated the heat transfer enhancement for one wall-ribbed rectangular channel of AR=5:1 with continuous, 90° and V-broken ribs and found that the enhancement of the 90° broken ribs is around 1.8 times over the continuous ribs. Cho et al. [17] examined the effect of angle of attack and number of discrete ribs in a square duct and observed that the gap region between the inclined discrete ribs accelerates the flow and enhances the local turbulence, which will results in an increase in the heat transfer. They also reported that the inclined rib arrangement with a downstream gap position shows higher enhancement in heat transfer compared to that of continuous inclined rib arrangement. Aharwal et al. [18] experimentally investigated the heat transfer enhancement due to a gap in an inclined continuous rib arrangement in rectangular duct of solar air heater and observed the optimum performance for relative gap width of 1.0 and at relative gap position of 0.25.Thakur et al. [19] performed study on absorber plate of solar air heater duct roughened with inclined discrete ribs. They reported that the maximum heat transfer enhancement occurs for the relative roughness pitch of 12, relative gap position of 0.35 and relative roughness height of 0.0498. The literature review reveals that discrete inclined or V-shaped rib arrangement can yield better performance as compared to continuous rib arrangement. Only few researchers have been given the information about the number of discretized parts of ribs in to which it should be broken so as to give the maximum thermal performance. Some of the researchers given the results of providing gaps in inclined ribs in leading and trailing edge of the ribs. However, investigations have not been carried out so far to optimize the gap width between rib elements to form the discrete rib and also to locate the optimum position of this gap, particularly in case of two opposite rib roughened walls which is used in gas turbine blade internal cooling. Therefore, present study has been performed to determine the optimum location and width of gap in an inclined rib to form a discrete rib for maximum thermal performance of a roughened square duct. II. EXPERIMENTAL PROGRAM A schematic diagram of the test set-up used in the present study is shown in figure 1. The wooden square duct has an internal size of 3750 mm x 75 mm x 75 mm, which consists of an entrance section, a test section and an exit section of length 1500 mm (20Dh), 1500 mm (20Dh) and 750 mm (10Dh) respectively [9]. The entrance unheated duct serves to establish hydro-dynamically fully developed flow at the entrance to the test duct and unheated exit section is used downstream of the test section in order to reduce the end effect in the test section. The exit end of the duct is connected to 81 mm internal diameter G. I. pipe provided with a calibrated orifice plate through a square to circular transition piece. The outside of entire set-up from inlet to the orifice plate, were covered with 25 mm thick thermocole sheet, so that the heat losses from the test section can be minimized.
  • 3. Thermo-Hydraulic Performance Of A Roughened Square Duct Having Inclined… 57 FIG. 1: Schematic diagram of experimental set-up The entrance and exit sections are made by 50 mm thick polished wooden walls. The square test duct consists of 6 mm thick heated aluminium plate on its top and bottom walls. The other two walls of test section are constructed by 50 mm thick polished wood. The ribbed aluminium plates are made by gluing square aluminium ribs (4.5 mm x 4.5 mm) to the finished aluminium plate surface in a required distribution to serve as top and bottom ribbed walls of the test section. The plates are heated from outside by means of separate heaters assembly, thus subjected to uniform heat flux (0-1500 W/m2 ) and are insulated with 50 mm thick glass wool topped with 12 mm thick plywood. A calibrated orifice-meter connected with an inclined U-tube manometer used to measure the mass flow rate of air through the duct. A control valve is provided in the pipe line to connect the blower to regulate the flow rate of air. The temperatures of the test plate are measured by 24 copper-constantan calibrated thermocouples, distributed along the length and across the span by drilling about 2 mm diameter holes around 3-4 mm deep at the back side of the plate. Four thermocouples are arranged span wise in the duct to measure the air temperature at exit of the test section and 2 thermocouples are used at inlet to the test section, to measure the entry temperature of air. A digital micro-manometer (Fluke-922) is used to measure the pressure drop across the test section. Experimental data is collected under steady- state condition for different mass flow rate of air to give the flow Reynolds number in the range of 5000 – 40,000. The heat flux was set and kept constant for each run so as to maintain the temperature of roughened plate around 200 C - 300 C above to that of mean bulk air temperature, to minimize the error. III. ROUGHNESS GEOMETRY AND RANGE OF PARAMETERS The dimensionless roughness parameters are determined by rib height (e), rib pitch (p), gap position (d) and gap width (g). The schematic of the geometry of inclined discrete rib used in the present study is shown in figure 2. The values of system and operating parameters are selected on the basis of related literature [4, 6, 9, 12, 13, 15, 17, 18, 19] and are given in Table I. FIG. 2: Schematic of roughness geometry of an inclined rib
  • 4. Thermo-Hydraulic Performance Of A Roughened Square Duct Having Inclined… 58 Table I: Range of parameters S. No. Parameters Range of parameter 1 Reynolds number, (Re) 5000 - 40000 2 Relative roughness height, (e/Dh) 0.060 3 Relative gap width, (g/e), 0.5, 1, 1.5 (3 steps) 4 Relative gap position, (d/W) 1/4,1/3,1/2 and 2/3 (4 steps) 5 Rib attack angle, (α) 450 6 Relative roughness pitch (p/e) 10 IV. DATA REDUCTION To determine heat transfer coefficient „h‟, useful heat gain „Qu‟, Nusselt number „Nu‟, Reynolds number „Re‟ and friction factor „f‟‟, the following procedure is adopted ; The mass flow rate, m, of air through the duct has been calculated from pressure drop measurement across the orifice plate.   5.0 4 1 ..2 ..            oa od P ACm (1) where, Cd is the coefficient of discharge which is determined as 0.610 by calibration. The pressure drop (ΔP)o across the orifice plate is given by (ΔP)o = 9.81 X (Δh)o X ρm X sinθ (2) The heat-transfer coefficient for the heated section was calculated as; )( fpp u TTA Q h   (3) where, heat transfer rate, Qu to the air is given by Qu = m Cp (To – Ti) (4) where Tp and Tf are average temperature values of test plate and fluid respectively. The average value of plate temperature (Tp) is calculated as a weighted mean of the plate temperature measured at different locations. The convective heat transfer coefficient is then used to obtain Nusselt number, Nu , as a h k hD Nu  (5) The Reynolds number was determined from the value of velocity of air through the duct, using equation: a haVD e   R (6) where, HW m V a ..  (7) The friction factor was determined from the measured values of pressure drop, (ΔP)d across the test section length, between the two points located 1.2 m apart. 2 4 )(2 VLρ DP f fa hd  (8) where, (ΔP)d is the pressure drop across the duct and is given by (ΔP)d = 9.81 X (Δh)d X ρm (9) The uncertainty analysis as proposed by Kline and McClintock [20] was used for the prediction of uncertainty associated with the experimental results based on the observations of the scatter in the raw data used in calculating the results. The uncertainties in the calculated values of Reynolds number, Nusselt number and Friction factor are estimated as ± 1.65 %, ± 1.94 %, ± 3.22 % respectively.
  • 5. Thermo-Hydraulic Performance Of A Roughened Square Duct Having Inclined… 59 V. VALIDATION OF EXPERIMENTAL DATA The values of Nusselt number and friction factor determined from the experimental data are compared with the values obtained with the standard Dittus-Boelter equation (Nuo= 0.023 Re0.8 Pr0.4 ) for the Nusselt number and Blasius equation (fo = 0.079 Re-0.25 ) for friction factor [21]. The comparison of the experimental and predicted values of Nusselt number and friction factor as a function of Reynolds number is shown in figure 3 and in figure 4 respectively. The average deviation between the predicted and experimental values has been found to be ±3.4 % and ±5.9 % for Nusselt number and friction factor respectively. This shows a good match between the two values, which ensures the accuracy of the experimental data with the present experimental set- up. FIG. 3: Comparison of experimental and predicted values of Nusselt number for smooth duct FIG. 4: Comparison of experimental and predicted values of friction factor for smooth duct VI. RESULTS AND DISCUSSION The effect of flow and roughness parameters on the thermal-hydraulic performance of an artificially rib-roughened square duct has been investigated and presented in Figs. 5- 9. Fig. 5 to Fig. 8 shows the effect of relative gap width on thermo-hydraulic performance for different relative gap positions at few selected Reynolds numbers. The thermo-hydraulic performance of roughened duct considerably increases due to gap in ribs as compared to smooth duct. As expected, the thermo-hydraulic performance of roughened duct decreases as the Reynolds number increases due to high turbulence effect at high Reynolds number for all the cases. It is observed that the maximum value of thermo-hydraulic performance occurs at relative gap width of 1 for all gap positions and also for all Reynolds numbers. This result conforms the result of Aharwal et. at. [17].The enhancement in thermo-hydraulic performance varies in the range of about 1.3 to 2.1 times of smooth duct (without ribs) in the range of flow parameter (Re varies from 5000 to 40000).
  • 6. Thermo-Hydraulic Performance Of A Roughened Square Duct Having Inclined… 60 FIG. 5: Effect of relative gap width on thermo-hydraulic performance for d/W = 1/4 FIG. 6: Effect of relative gap width on thermo-hydraulic performance for d/W = 1/3 The thermo-hydraulic performance increases with increase in gap width from 0.5 to 1.0 beyond which it decreases with increase in gap width throughout the range of Reynolds number. This is prompted as by creating a gap in rib, it promotes local turbulence and flow mixing along the gap flow region while the rib induced secondary flow is usually maintained in the duct. It may, therefore, reasoned that the widening the gap width beyond 1 reduces the flow velocities through the gap and hence local turbulence, whereas too small gap width will not allow sufficient amount of secondary flow of fluid to pass through it and hence the turbulence level will remain low which ultimately results in low Nusselt number ratio (Nur/Nuo) as compared to g/e =1. To bring out the effect of relative gap position clearly, the value of thermo-hydraulic performance is plotted as a function of relative gap position and is shown in Fig.10 at few selected Reynolds number and for relative gap width of 1.0. It is clear that thermo-hydraulic performance attains a maximum value at relative gap position of 1/3. It is note that the inclination of rib creates a high heat transfer region at the leading edge and a low heat transfer region at the trailing edge [22]. The gap in trailing edge region helps in improving the Nusselt number ratio and is observed till the gap position is about 1/3 of the duct width. The gap at a position close to duct wall (d/w = 1/4) is not likely to produce similar effect as lateral boundary layer near to the wall may plays a dominant role. Thus placing the gap closer to the trailing edge side of inclined rib reckons poor results. Whereas, if, a gap is created near the leading edge (d/w = 2/3) the secondary flow weakens and thus this gap position does not lead to significant increase in thermo-hydraulic performance.
  • 7. Thermo-Hydraulic Performance Of A Roughened Square Duct Having Inclined… 61 FIG. 7: Effect of relative gap width on thermo-hydraulic performance for d/W = 1/2 FIG. 8 Effect of relative gap width on thermo-hydraulic performance for d/W = 2/3 FIG. 9: Effect of relative gap position on thermo-hydraulic performance for g/e = 1
  • 8. Thermo-Hydraulic Performance Of A Roughened Square Duct Having Inclined… 62 VII. CONCLUSION On the basis of experimental results it is found that by providing gap in the inclined rib, there is considerable enhancement in thermo-hydraulic performance of a square opposite side artificially roughened duct. The main findings are: 1. The thermo-hydraulic performance of roughened surface having inclined ribs with a gap yields an increase of about 2.1 times as compared to that of smooth duct in the range of Reynolds number from 5000 to 40000. 2. The value of thermo-hydraulic performance decreases with the increase in Reynolds number. 3. The relative gap position of 1/3 and the relative gap width of 1 give the highest value of thermo- hydraulic performance parameter. NOMENCLATURE A Area of duct cross section, m2 Ap Area of roughened plate, m2 Apipe cross section area of pipe, m2 AR Channel aspect ratio (W/H) Cd Coefficient of discharge for orifice meter Cp Specific heat of air at const. pressure, J/kg K Dh Channel hydraulic diameter of duct, m (= 4 W H /2(W+H)) Dp Inside diameter of pipe, m d/W Relative gap position e Rib height, m e/Dh Relative roughness height f friction factor fo Friction factor for smooth circular duct fr Friction factor for roughened duct fr / fo Friction factor ratio g/e Relative gap width H Depth of duct, m h Convective heat transfer coefficient, W/m2 K ka Thermal conductivity of air, W/m K L Test section length, m Lf Duct length to calculate friction factor, m L/Dh Test length to hydraulic diameter ratio m mass flow rate, kg/s Nu Nusselt number Nuo Nusselt number for smooth circular duct Nur Nusselt number for roughened duct Nur/Nuo Nusselt number ratio p Rib pitch, m Pr Prandtl number (ΔP)d Pressure drop in the test channel, N/m2 (ΔP)o Pressure drop across the orifice plate, N/m2 p/e Relative roughness pitch Qu Useful Heat gain, W Re Reynolds number Tf Bulk mean air temperature, 0 C or K Ti Air inlet temperature, 0 C or K To Air outlet temperature, 0 C or K Tp Mean plate temperature, 0 C or K V Velocity of air, m/s W Width of duct, m GREEK SYMBOLS α Rib angle of attack, degree β Ratio of orifice diameter to pipe diameter θ Angle of inclination of U-tube manometer µa Dynamic viscosity of air, N s m-2 ρa Density of air, kg m-3 ρm Density of manometer fluid, kg m-3 REFERENCES [1] M. J. Lewis, “Optimizing the thermo hydraulic performance of rough surface”, international Journal of Heat and Mass transfer”, 18, (1975), pp. 1243-1248. [2] J. C. Han, S. Dutta, and S. V. Ekkad, “Gas Turbine Heat Transfer and Cooling Technology”, Taylor & Francis, Inc., New York, (2001). [3] J.C. Han, L.R. Glicksman, and W.M. Rohsenow, “An Investigation of Heat Transfer and Friction for Rib-Roughened Surfaces,” International Journal of Heat and Mass Transfer, 21, (1978), pp. 1143- 1156. [4] J.C. Han and J.S. Park, “Developing Heat Transfer in Rectangular Channels with Rib Turbulators,” International Journal of Heat and Mass Transfer, 31,(1988), pp. 183-195. [5] B. V. Johnson, J. H. Wagner, G. D. Steuber, and F. C. Yeh, „„Heat Transfer in Rotating Serpentine Passages With Selected Model Orientations for Smooth or Skewed Trip Walls,‟‟ ASME Paper 93-GT- 305 (1993). [6] M. E. Taslim, „„An Experimental Investigation of Heat Transfer Coefficients in a Spanwise Rotating Channel With Two Opposite Rib-Roughened Walls,‟‟ ASME Journal of Turbomachinery, 113, (1991), pp. 75–82. [7] J. C. Han, „„Heat Transfer Enhancement in Channels With Turbulence Promoters,‟‟ ASME J. of Engg. Gas Turbines Power, 106, (1985), pp. 774–781.
  • 9. Thermo-Hydraulic Performance Of A Roughened Square Duct Having Inclined… 63 [8] J. H. Wagner,„„Heat Transfer in Rotating Serpentine Passages With Trips Normal to the Flow,‟‟ ASME Journal of Turbomachinery, 114, (1992), pp. 847–457. [9] J.C. Han and Y.M. Zhang, “High Performance Heat Transfer Ducts with Parallel and V-Shaped Broken Ribs,” International Journal of Heat and Mass Transfer, 35, (1992), pp. 513-523. [10] R. Kiml, S. Mochizuki, A. Murata „„Effects of rib arrangements on heat transfer and flow behavior in a rectangular rib roughened passage , Journal of heat transfer, 123,(2001), pp. 675-681. [11] S.C. Lau, R.D. McMillin, J.C. Han, “Heat Transfer characteristics of turbulent flow in a square channel with angled rib”, Trans. ASME, Journal of Turbomachinery, 113, (1991), pp 367-374. [12] J.S. Park, J.C. Han, Y. Huang, S. Ou, “Heat transfer performance comparisons of five different rectangular channels with parallel angled ribs”, International Journal of Heat Mass Transfer, 35 (11), (1992), pp. 2891–2903. [13] M.E. Taslim , and C.M. Wadsworth, "An experimental investigation of rib surface- average Heat Transfer Coefficient in Rib-Roughened Square Passage", Journal of Turbomachinery, 119(2),(1997), pp. 381-389. [14] H.H. Cho, S.J. Wu, and H.J. Kwon, “Local Heat/Mass Transfer Measurements in a Rectangular Duct with Discrete Ribs,” ASME Journal of Turbomachinery, 122 (2000), pp. 579-586. [15] S.C. Lau, R.D. McMillin, J.C. Han, “Turbulent heat transfer and friction in a square channel with discrete rib turbulators”, Trans ASME, Journal of Turbomachinery,113, (1991), pp. 360-366,. [16] G. Tanda, “Heat transfer in rectangular channel with transverse and V-shaped broken ribs”, Int. Journal of Heat and Mass Transfer, 47, (2004), pp. 229–243. [17] H.H. Cho, Y.Y. Kim, D.H. Rhee, S.Y. Lee, S.J. Wu, “The effect of gap position in discrete ribs on local heat/mass transfer in a square duct”, Journal of Enhanced Heat Transfer, 10 (3), (2003), pp. 287-300. [18] K. R. Aharwal, B. K. Gandhi, J. S. Saini, “Experimental investigation on heat-transfer enhancement due to a gap in an inclined continuous rib arrangement in a rectangular duct of solar air heater”, Journal of Renewable Energy, 33 (2008), pp. 585-596. [19] S. K. Thakur, V Mittal, N. S. Thakur, and A. Kumar, “Heat Transfer and Friction Factor Correlations for rectangular Solar Air Heater Duct Having 60° Inclined Continuous Discrete Rib Arrangement”, British Journal of Applied Science & Technology,1(3), (2011), pp. 67-93. [20] J. P. Holman, Experimental methods for engineers, Tata Mcgraw Hills, New Delhi, 2004. [21] M. S. Bhatti, R. K. shah, “Turbulent and transition flow convective heat transfer, Handbook of Single-phase Convective Heat Transfer, wiley, New York, 1987. [22] J. C. Han, W. L. Fu, L. M. Wright, “ Thermal performance of angled, V-shaped and W-shaped rib tabulators in rotating rectangular cooling channel”, Trans. ASME, Journal of Turbomachinery, (2004),126, pp. 604-614.