2. Architecture 324
Structures II
Column Analysis and Design
•
•
•
•
•
•
Failure Modes
End Conditions and Lateral Bracing
Analysis of Wood Columns
Design of Wood Columns
Analysis of Steel Columns
Design of Steel Columns
University of Michigan, TCAUP
Structures II
Slide 2/19
3. Leonhard Euler (1707 – 1783)
Euler Buckling (elastic buckling)
Pcr =
–
–
–
–
–
π 2 AE
KL
r
2
r=
I
A
A = Cross sectional area (in2)
E = Modulus of elasticity of the material (lb/in2)
K = Stiffness (curvature mode) factor
L = Column length between pinned ends (in.)
r = radius of gyration (in.)
f cr =
π 2E
KL
r
University of Michigan, TCAUP
2
Source: Emanuel Handmann (wikimedia commons)
≤ Fcr
Structures II
Slide 3/19
4. Failure Modes
•
Short Columns – fail by crushing
(“compression blocks or piers” Engel)
fc =
–
–
–
–
•
P
≤ Fc
A
fc = Actual compressive stress
A = Cross-sectional area of column (in2)
P = Load on the column
Fc = Allowable compressive stress per codes
Intermediate Columns – crush and buckle
(“columns” Engel)
•
Long Columns – fail by buckling
(“long columns” Engel)
f cr =
–
–
–
–
π 2E
KL
r
2
≤ Fcr
E = Modulus of elasticity of the column material
K = Stiffness (curvature mode) factor
L = Column length between pinned ends (in.)
r = radius of gyration = (I/A)1/2
University of Michigan, TCAUP
Structures II
Slide 4/19
5. Slenderness Ratio
•
Radius of Gyration: a geometric
property of a cross section
r=
–
–
–
•
I
A
I = Ar 2
r = Radius of Gyration
I = Moment of Inertia
A = Cross-sectional Area
rx = 0.999
Slenderness Ratios:
Lx
rx
Ly
ry
The larger ratio will govern.
Try to balance for efficiency
University of Michigan, TCAUP
ry = 0.433
Structures II
Slide 5/19
6. End Support Conditions
K= 1.0
K is a constant based on the end conditions
l is the actual length
Both ends pinned.
l e is the effective length
l e = Kl
K= 0.7
One end free, one end fixed.
K= 2.0
K= 0.5
Both ends fixed.
One end pinned, one end fixed.
University of Michigan, TCAUP
Structures II
Slide 6/19
7. Analysis of Wood Columns
Data:
•
•
•
Column – size, length
Support conditions
Material properties – Fc , E
Required:
•
Pcrit for buckling and crushing
•
Calculate slenderness ratio; largest ratio
governs.
Check slenderness against upper limit.
Calculate Pcrit for buckling using Euler’s
equation:
Calculate Pmax for crushing:
Pmax = Fc A
Smaller of Pcrit or Pmax will fail first.
•
•
•
•
University of Michigan, TCAUP
Structures II
Slide 7/19
8. Example Problem :
Analysis
Data: section 3”x7” Full Dimension
Fc = 1000 psi
E = 1,400,000 psi
Find: Pcritical for buckling and crushing.
Determine the mode of failure
for the wood column.
University of Michigan, TCAUP
Structures II
Slide 8/19
9. Example Problem : Analysis (cont.)
1.
Calculate slenderness ratios
for each axis.
The larger (more slender) controls.
2.
Upper limits are usually given by codes.
University of Michigan, TCAUP
Structures II
Slide 9/19
10. Example Problem : Analysis (cont.)
3.
Calculate critical Euler buckling load.
4.
Calculate crushing load.
5.
Smaller of the two will fail first and control.
University of Michigan, TCAUP
Structures II
Slide 10/19
11. Analysis of Steel Columns
by Engel
Data:
•
•
•
•
Column – size, length
Support conditions
Material properties – Fy
Applied load - Pactual
Required:
•
Pactual < Pallowable
•
Calculate slenderness ratios.
The largest ratio governs.
•
Check slenderness ratio against upper limit of 200
•
Use the controlling slenderness ratio to find the
critical Euler buckling stress, fcr.
•
Apply some Factor of Safety (like 3) to fcr.
•
Determine yield stress limit, Fy.
•
Fallowable is the lesser stress: (fcr / F.S.) or Fy
•
Compute allowable capacity: Pallowable = Fallow A.
•
Check column adequacy:
Pactual < Pallowable
University of Michigan, TCAUP
Structures II
π 2E
f cr =
2
KL
r
Slide 11/19
12. Design of Steel Columns
by Engel
Data:
•
•
•
•
Column – length
Support conditions
Material properties – Fy
Applied load - Pactual
Required:
•
Column – section
•
Use the Euler equation to solve for Ar2 which is
equal to I for both x and y axis.
•
Enter the section tables and find the least weight
section that satisfies BOTH Ix and Iy.
•
Check the slenderness ratios are both < 200.
•
Calculate the actual Euler stress fcr for the final
section.
•
Fallowable is the lesser stress: fcr / F.S. or Fy
•
Compute allowable capacity: Pallowable = Fallow A.
University of Michigan, TCAUP
Structures II
P( K xl x ) 2
Ix =
× F .S .
2
π E
Iy =
P( K y l y ) 2
π E
2
× F .S .
Slide 12/19
13. Example Problem : Design
Select a steel section that can carry the given load.
University of Michigan, TCAUP
Structures II
Slide 13/19
14. Example Problem : Design (cont.)
University of Michigan, TCAUP
Structures II
Slide 14/19
15. Example Problem : Design (cont.)
• Determine the controlling
slenderness (larger controls)
• Find the actual buckling stress,
fcr
• Compare to allowable stress,
Fallowable is lesser of :
fcr/F.S. or Fy
• Determine safe allowable load,
Pallowable = Fallowable A
University of Michigan, TCAUP
Structures II
Slide 15/19
16. Determining K factors
by AISC
Sidesway Inhibited:
Braced frame
1.0 > K > 0.5
Sidesway Uninhibited:
Un-braced frame
unstable > K > 1.0
If Ic/Lc is large
and Ig/Lg is small
The connection is more pinned
If Ic/Lc is small
and Ig/Lg is large
The connection is more fixed
Source: American Institute of Steel Construction, Manual of Steel Construction, AISC 1980
University of Michigan, TCAUP
Structures II
Slide 16/19
18. Analysis of Steel Columns
by AISC-ASD
Data:
•
•
•
•
Column – size, length
Support conditions
Material properties – Fy
Applied load - Pactual
Required:
•
Pactual < Pallowable
•
Calculate slenderness ratios.
largest ratio governs.
In AISC Table look up Fa for given
slenderness ratio.
Compute: Pallowable = Fa A.
Check column adequacy:
Pactual < Pallowable
•
•
•
Source: American Institute of Steel Construction, Manual of
Steel Construction, AISC 1980
University of Michigan, TCAUP
Structures II
Slide 18/19
19. Design of Steel Columns
with AISC-ASD Tables
Data:
•
•
•
•
Column – length
Support conditions
Material properties – Fy
Applied load - Pactual
Required:
•
Column Size
1.
2.
Enter table with height.
Read allowable load for each section to
find the smallest adequate size.
Tables assume weak axis buckling. If
the strong axis controls the length must
be divide by the ratio rx/ry
Values stop in table (black line) at
slenderness limit, KL/r = 200
3.
4.
University of Michigan, TCAUP
Source: American Institute of Steel Construction, Manual of Steel
Construction, AISC 1980
Structures II
Slide 19/19
Hinweis der Redaktion
PvB
Leonhard Euler portrait by Emanuel Handmann, 1753
http://commons.wikimedia.org/wiki/File:Leonhard_Euler_by_Handmann_.png
Public domain
http://en.wikipedia.org/wiki/Emanuel_Handmann
PvB
PvB
PvB
PvB
PvB
PvB
PvB
PvB
This is the steel code
[2] Manual of steel construction.
Author American Institute of Steel Construction.
Edition 8th ed.
Published Chicago, Ill. : American Institute of Steel Construction, c1980.
p. 3-5