2. IntroductionIntroduction
Microscopes magnify & resolve images
‘Its not how much they magnify that is key -
but how well they resolve…’
Invented in 1930s, but not used much until
after WW-II.
1932, produced the world's first
transmission electron microscope
(TEM).
German physicist Ernst Ruska and
German electrical engineer Max Knoll
constructed the prototype electron
microscope.
S S Jena
3. Invention of EM
In 1932, invented by E. Ruska et al.
In 1986, Ruska received the Nobel Prize.
S S Jena
4. Contd…
The transmission electron microscope
(TEM) was the first type of Electron
Microscope to be developed
The first scanning electron microscope
(SEM) debuted in 1938 ( Von Ardenne)
with the first commercial instruments
around 1965.
Its late development was due to the
electronics involved in "scanning" the
beam of electrons across the sample.
S S Jena
5. Imaging with a simple lens
α
α = semi-angular aperture
object
plane
image
plane
<<< conjugate planes of focus >>>
axis of lens
S S Jena
6. Focal length
f
f = focal length of lens
parallel
rays of light
axis
back focal plane of lens >>>
Distance between center of lens
and focal point is the focal length
S S Jena
8. Resolution
The limit of resolution of a microscope is
the smallest distance between 2 points
that can be seen using a microscope
This is a measure of the clarity of the
image
As Magnification increases, resolution
decreases.
Resolving power is inversely proportional
to the wavelength of the radiation it uses
S S Jena
9. Resolution
dmin =
0.61 λ
n sin α
n = refractive index
λ = wavelength
d
note: resolving power independent of lens properties
: for green (500nm) light dmin = c. 0.2 µm
S S Jena
10. The Light Microscope
Series of lenses through which
ordinary white light can be
focused.
Optical microscopes can not
resolve 2 points closer together
than about half (0.45) the
wavelength of the light used (450-
600nm).
The total magnification is the
eyepiece magnification multiplied
by the objective magnification.
The maximum magnification of a
light microscope is x1500 &
resolution up to 0.2 µm.
S S Jena
11. The Electron Microscope
Electrons (negatively charged very
small particles) can behave as waves.
The wavelength of electrons is about
0.005nm
Electrons are ‘fired’ from an electron
gun at the specimen and onto a
fluorescent screen or photographic
plate
Electrons scatter when they pass
through thin sections of a specimen
There are 2 major types of electron
microscopy - transmission and
scanning
Both focus an electron beam onto the
specimen using electromagnets
S S Jena
12. Comparison of Optical and Electron MicroscopesComparison of Optical and Electron Microscopes
Electron microscopes are operated in vacuum because
the mean free path of electrons in air is short – this mean
biological samples should not degas – they can either be
dehydrated or frozen
Electron microscopes have higher resolution than optical
microscopes – atomic resolution is possible.
Chemical imaging and spectroscopy – mapping π and σ
bonds at 1nm resolution can be done.
S S Jena
13. Why high vacuum ?
Mean free path of electron is very
short in air
Tungsten filaments burn out in air
Columns must be kept dust free
Achieved by two fold pumping:
Rotary (mechanical) pump +
Diffusion pump or + turbo pump
S S Jena
15. In transmission EM the electrons
pass through the specimen
Specimen needs to be extremely
thin - 10nm to 100nm
TEM can magnify objects up to
500 000 times
TEM has made it possible to see
the details of interior views and
discover new organelles
Cells or tissues are killed and
chemically ‘fixed’ in a complicated
and harsh treatment
Transmission Electron Microscope (TEM)Transmission Electron Microscope (TEM)
S S Jena
16. TEM contd…
Has a resolution 1000 times
better than light microscope
(0.2nm)
Transmitted electrons (those that
do not scatter) are used to
produce image
Denser regions in specimen,
scatter more electrons and
appear darker
S S Jena
17. The process
Electrons are emitted by an electron gun,
commonly fitted with a tungsten filament
cathode
Electric field accelerates
Magnetic (and electric) field control path
of electrons
Electron wavelength @ 200KeV ≈ 2x10-12
m
Resolution normally achievable @
200KeV ≈ 2 x 10-10
m ≡ 2Å
S S Jena
18. Components of a Transmission MicroscopeComponents of a Transmission Microscope
Thermionic Gun:
Electron source.
Triode or self-biasing gun
W, LaB6, CeB6
If misaligned, low intensity & other
alignments may also be out
S S Jena
19. Electron gun
Brightness = electron
current by a source
with unit area and unit
solid angle
Bias (Wehnelt)
Cylinder
Filament (20-100 KV)
Anode
stream of electrons originating
from outer shell of filament atoms
S S Jena
20. Lenses
Provide means to (de)focus the electron
beam on the specimen, to focus the
image, to change the magnification, and
to switch between image and diffraction
Electromagnetic lenses are based on the
fact the moving electrons are forced into a
spiral trajectory, i.e. focused into one point
S S Jena
21. The electromagnetic lens
Works at fixed focal
distance and variable focal
length.
(like the human eye lens but
unlike light optics)
windings
soft iron
pole piece
windings
e-
electrons are charged, and are therefore
deflected when they cross a magnetic field
S S Jena
22. Lens system
a) Condenser lens:
Uniformly illuminate the sample.
Usually 2; C1 and C2 lens
If misaligned, we will lose the beam when changing
magnification
b) Objective lens:
Image sample – determines resolution.
If misaligned, the image will be distorted, blurry.
c) Projector lens:
magnifies image/ forms diffraction pattern – should not alter
resolution.
If misaligned, the image will be distorted, diffraction pattern
may be blurry.
S S Jena
26. Sample preparation
1. Chemical fixation:
Proteins with formaldehyde and glutaraldehyde and
lipids with osmium tetroxide.
2. Cryofixation:
Freezing a specimen so rapidly, to liquid nitrogen or even
liquid helium temperatures, that the water forms vitreous
(non-crystalline) ice.
3. Dehydration:
Freeze drying, or replacement of water with organic
solvents such as ethanol or acetone, followed by critical
point drying or infiltration with embedding resins.
S S Jena
27. Contd…
4. Embedding
The tissue is passed through a 'transition solvent' such as
epoxy propane and then infiltrated with a resin such as
Araldite epoxy resin
Tissues may also be embedded directly in water-miscible
acrylic resin
After the resin has been polymerised (hardened) the
sample is thin sectioned (ultrathin sections) and stained - it
is then ready for viewing.
5. Sectioning
These can be cut on an ultramicrotome with a diamond
knife to produce ultrathin slices about 60-90 nm thick.
Disposable glass knives are also used because they can be
made in the lab and are much cheaper.
S S Jena
28. 6. Staining
Uses heavy metals such as lead,
uranium or tungsten to scatter
imaging electrons and thus give
contrast between different
structures, since many biological
materials are nearly "transparent"
to electrons (weak phase objects).
Contd…
S S Jena
29. Freeze-fracture or freeze-etch
A preparation method particularly useful for examining
lipid membranes and their incorporated proteins in "face
on" view.
The fresh tissue or cell suspension is frozen rapidly
(cryofixed), then fractured by simply breaking or by using
a microtome while maintained at liquid nitrogen
temperature.
The cold fractured surface is then shadowed with
evaporated platinum or gold at an average angle of 45°
in a high vacuum evaporator.
A second coat of carbon, evaporated perpendicular to
the average surface plane is often performed to improve
stability of the replica coating.
S S Jena
30. The specimen is returned to room
temperature and pressure, then the
extremely fragile "pre-shadowed" metal
replica of the fracture surface is released
from the underlying biological material by
careful chemical digestion with acids,
hypochlorite solution or SDS detergent.
The still-floating replica is thoroughly
washed from residual chemicals,
carefully fished up on fine grids, dried
then viewed in the TEM.
Contd…
S S Jena
32. TEM Limitations
Specimen dead.
Specimen preparation uses
extreme chemicals so artifacts
are always a concern.
S S Jena
33. Live specimens possible. No
sectioning is required.
Magnify objects up to two
million times.
Lower magnifications than the
TEM.
Resolving power is about
20nm
In Scanning EM microscopes the electrons bounce off
the surface of the specimen
Produce images with a three-dimensional appearance
Allow detailed study of surfaces.
Scanning Electron Microscope (SEM)Scanning Electron Microscope (SEM)
S S Jena
37. Sample preparation
All water must be removed from the
samples because the water would
vaporize in the vacuum.
All metals are conductive and require no
preparation before being used.
All non-metals need to be made
conductive by covering the sample with a
thin layer of conductive material.
This is done by using a device called a
"sputter coater.“
E.g. gold coating
S S Jena
39. TEM Vs SEM images
TEM- interior SEM- surfaceS S Jena
40. EM VariationsEM Variations
High Voltage TEM
Scanning tunneling microscope
Scanning transmission electron
microscope (STEM)
Scanning probe microscope
Atomic force microscope
Environmental scanning electron
microscope
Elemental Composition SEM
S S Jena
41. ApplicationsApplications
Morphology (imaging)
Crystal structures (diffraction)
Protein localization
Electron & Cellular tomography
Toxicology
Biological production and viral load
monitoring
Particle analysis
Materials qualification
Structural biology
Virology
Forensics
Mining (mineral liberation analysis)
S S Jena
42. Disadvantages of EMDisadvantages of EM
Expensive to build and maintain
Requires extremely stable high-voltage supplies,
extremely stable currents to each electromagnetic
coil/lens, continuously-pumped high- or ultra-high-
vacuum systems, and a cooling water supply circulation
through the lenses and pumps.
As they are very sensitive to vibration and external
magnetic fields, must be housed in stable buildings
(sometimes underground) with special services such as
magnetic field cancelling systems.
The samples largely have to be viewed in vacuum
S S Jena
43. Light Vs Electron Microscopes
Feature Light Microscope Electron Microscope
Radiation used
Radiation source
Nature of lenses
Lenses used
Image seen
Radiation medium
Magnification
Limit of resolution
What it can show
S S Jena