Research Inventy: International Journal of Engineering And Science
Vol.4, Issue 7 (July 2014), PP 77-85
Issn (e): 2278-4721, Issn (p):2319-6483, www.researchinventy.com
77
Manufacturing and Comparative Analysis of Threaded Tube
Heat Exchanger with Straight Tube Heat Exchanger
Prof.N.B.Totala1
, Prof.V.P.Desai2
, Pratik Gawade3
, Nikhil Kakade4
,Anant
Paralkar5
, ArpitBanerjee6
, Shreenath Agarwal7
1,2
(Assistant Professor, Department of Mechanical Engineering, MIT Academy of Engineering,Alandi (D), Pune,
Maharashtra, 412105)
3,4,5,6
(Department of Mechanical Engineering, MIT Academy of Engineering, Alandi(D), Pune, Maharashtra,
412105)
7
(Assistant Manager, Production G Series, Greaves Cotton Ltd, Diesel Engine Unit, Akurdi.Pune.)
ABSTRACT: To intensify the heat transfer from the heat exchanger surface to fluid, it is possible to increase
convection coefficient, widen temperature difference between surface and fluid or increase the surface area
across which convection occurs. Extended surfaces, in the form of longitudinal or radial fins are common in
applications where the need to enhance the heat transfer between a surface and an adjacent fluid exists. Fins
are commonly used in extended surface exchangers. To minimize the size of heat exchangers, fins are used to
increase the surface area and the heat transfer rate between the heat exchanger surface and the surroundings.
Both the conduction through the fin cross section and the convection over the fin surface area take place in and
around the fin, the temperature value is limited by the type of material and production technique. Due to all
above, finned tube heat exchangers are used in different thermal systems for applications where heat energy is
exchanged between different media. Applications range from very large to the small scale (tubes in heat
exchangers, the temperature control of electronic components).The subject, which is investigated in this paper,
is concentrated on increasing heat transfer rate by provided extended surfaces like threads. By providing
threads, heat transfer area increases and it leads to better heat transfer due to turbulence.
KEYWORDS: Heat transfer co-efficient, Nusselt number, Reynolds number, Thermal conductivity,
I. INTRODUCTION
The performance of a conventional heat exchanger, which is an essential unit in heat extraction and
recovery systems, can be substantially improved by a number of augmentation techniques. Common thermal-
hydraulic goals are to reduce the size of heat exchanger required for specified heat duty, to upgrade the capacity
of an existing heat exchanger, to reduce the approach temperature difference for the process streams, or to
reduce the pumping power. A preferred approach to the problem of increasing heat exchanger effectiveness,
while maintaining minimum heat exchanger size and operational cost, is to increase the heat transfer exchange
rate.The addition of fins reduces the thermal resistance on that side and thereby increases the net heat transfer
from/to the surface for thesame temperature difference. The heat transfer coefficient can also be higher for
fins.To develop the correlations for forced convection for the inner pipe in tube in tube heat exchanger having
threaded shape using experimental and numerical techniques. This geometry is expected to augment heat
transfer for vortex shedding and turbulence because of internal curvatures and enhanced area available for heat
transfer.In order to do so, the experiments employ tube in tube heat exchanger with two configurations of the
inner tube namely straight smooth tube and threaded tube. The experimentation will be conducted for the
Reynolds number in turbulent region ranging from 6000 to 25,000.
A.E. Bergles, [1] showed that heat energy is conserved by heat transfer enhancement.C.A. Balaras, [2]
reviewed of augmentation techniques for heat transfer surfaces in single-phase heat exchangers.Wolverine INC
[3] An engineering data book was referred to have a insight for enhanced heat exchangers. Kim[4]Studied the
characteristics of flat plate finned-tube heat exchangers with large fin pitch. In this study, 22 heat exchangers
were tested with a variation of fin pitch, number of tube row, and tube alignment. The air-side heat transfer
coefficient decreased with a reduction of the fin pitch and an increase of the number of tube row. The reduction
in the heat transfer coefficient of the four-row heat exchanger coil was approximately 10% as the fin pitch
decreased from 15.0 to 7.5 mm over the Reynolds number range of 500–900 that was calculated based on the
tube diameter. For all fin pitches, the heat transfer coefficient decreased as the number of tube row increased
from 1 to 4. The staggered tube alignment improved heat transfer performance more than 10% compared to the
Manufacturing and Comparative Analysis ...
78
inline tube alignment. A heat transfer correlation was developed from the measured data for flat plate finned-
tubes with large fin pitch. The correlation yielded good predictions of the measured data.HT-307[5] was referred
to determine the efficiency of given longitudinal /pin fin and compare it with the theoretical value for the given
fin. Creed Taylor [6] researched on types of heat exchangers used in refrigeration system and its environmental
impact. Friedrich Frass[7] studied principles in heat exchanger designing and constructing heat
exchangers with transverse finned tubes in cross-flow, it is necessary to know correlations for calculating heat
transfer and pressure drop. In addition to the common use of the Reynolds and Nusselt groups of dimensionless
numbers, heat conduction in the fins also has to be accounted for calculating the heat transfer. A reduction
coefficient termed “fin efficiency” is therefore introduced, by which the actual heat transfer coefficient is
multiplied in order to get the apparent heat transfer coefficient. J.A. Livinstone [8] studied heat transfer
enhancement with different types of fins and studied the heat transfer rates. Shiv Kumar Rathor [9] identified
the advantages of low-finned tube Heat Exchangers over Plain tube (Bare Tube) units. To use finned tubes to
advantage in this application, several technical issues were to be addressed. Shell side and tube side pressure,
cost, weight and size of heat exchanger. Hamid Nabati[10] studied on results of heat transfer rates and pressure
drop with different types of fins. The heat exchanger used for this research consists of a rectangular duct fitted
with different shape pin fins, and is heated from the lower plate.
The pin shape and the compact heat exchanger (CHE) configuration were numerically studied to
maximize the heat transfer and minimize the pressure drop across the heat exchanger. A.D.Kadam[11] carried
out simulation of fin and tube type heat exchanger with the help of computer simulation software. Sandeep R.
Desai [12]carried out analysis of fluid elastic vibrations of heat exchanger tubes and its determination of modal
parameters (natural frequency and damping ratios) of the tubes. Kevin Lunsford [13] published a technical paper
on how to improve the heat exchanger performance with simulation programs commercial feasibility etc.K P M
Wipplinger [14] designed a stainless steel finned tube heat exchanger. M V Ghori [15] experimented three-
dimensional CFD simulation and carried out investigation on heat transfer and fluid flow characteristics of two-
row plain Tube and Fin heat exchanger using FLUENT software. Jiin-Yuh Jang [16] this paper suggests a
method for finding the optimal louver angle of a fin heat exchanger by use of simplified conjugate-gradient
method (SCGM) and a three-dimensional computational fluid dynamics model. AlaHasan [17] conducted the
performance of two evaporatively cooled heat exchangers is investigated under similar operating conditions of
air flow rates and inlet hot water temperatures. The heat exchangers are plain and plate-finned circular tube
types which occupy the same volume. Chi-ChuanWang[18] the objective of this paper is to summarize the
recent progress of fin pattern designs. Some of the designs are from the applied patents and some are from the
recent literatures. The fin patterns include interrupted surfaces, enhanced wavy and the vortex generators.
Benefits and the associated constraints of these designs are discussed. S.F Tsai [19]A three-dimensional
numerical study was conducted to assess the heat transfer performance of extended fins in a two-row finned tube
heat exchanger. Fins under investigation were plane and slit types. A finite volume discretization method and a
SIMPLE-based solution algorithm were, respectively, applied to working differential equations and their
discrete counterparts to compute the gas velocities and pressure. W. K. Ding [20] .A circuit data structure
(circuit connection network) for a general description of different circuit configurations in computer programs is
presented. On basis of this data structure, a general tube-by-tube simulation model and the corresponding code
for prediction of plate fin-and-tube heat exchanger performance are developed.
Dimensional Parameters Threaded tube (mm)
(Aluminium)
Straight Tube (mm)
(Aluminium)
Length of the heat exchanger 1000 1000
Inner diameter of the inner tube, di 16 16
Outer diameter of the inner tube, do 26 25
Inner diameter of the outer tube, Di 36 36
Outer diameter of the outer tube, Do 42 42
Pitch distance between threads 2.4 -
Depth of threads 1.5 -
II. METHODOLOGY AND EXPERIMENTATION
Geometry is ascertained based on literature survey, pipe sizes available in market and heat duty.
Manufacturing and fabrication of threaded tube.
Insertion of simple instrumentation for thermal measurement.
Study of variation of Reynolds number on the Nusselt number.
Reduction of data to construct useful heat transfer correlations.
A schematic diagram of the experimental apparatus is shown in Fig 1. The test loops consists of a test section,
hot water loop, cold water loop and data measuring systems.
Manufacturing and Comparative Analysis ...
79
Fig1. Schematic Diagram
1. Suction Pipe 2.Heaters 3. Cold Water Pipe 4. Hot Water Sensor 5. Cold Water Sensor
6. Cold Pipe Outlet 7. Threaded Heat Pipe. 8. M.S Outer Pipes 9. Non Threaded Heat Pipe
10. Delivery Pipe 11. FCV 12.Cold Pipe Inlet
The test section is the water-to-water single-phase horizontal double pipe heat exchanger with two
different configurations of the inner tube (threaded and non threaded).
2.1experimental Analysis
A basic strategy to evaluate the heat exchanger’s performance is through the study of parameters like
Nusselt Number, Reynolds number, etc and their impact on the overall heat transfer coefficient of the heat
exchanger. In result table, LMTD, overall heat transfer coefficient, Nusselt numbers across the inner tube are
calculated. The collected data is processed, analyzed and presented Reynolds number (1500 – 31000 range) and
mass flow rates (0.055 to 0.220 kg/s)
III. DESIGN OF DOUBLE PIPE HEAT EXCHANGER BY KERN METHOD
FOR GIVEN SPECIFICATIONS
Hot fluid inlet temperature, Thi= 65°C = 338K
Cold fluid inlet temperature, Tci= 30°C = 303K
Mass flow rate for hot fluid (water), qh = 200LPH
Mass flow rate for cold fluid (water), qc = 200LPH
For the process conditions specified above, design the double pipe heat exchanger of 2000W heat duty.
Thermo-physical properties Hot fluid (water) at
65°C
Cold fluid (water) at
30°C
Density, ρ (kg/m3
) 987.7 997.46
Thermal conductivity, k (W/m-K) 0.658 0.619
Specific heat, Cp (J/Kg-K) 4182 4182
Viscosity, μ (Pa-s) 0.422 x 10-3
0.777 x 10-3
Prandtl number, Pr 2.6062 5.1078
Various heat transfer equations and empirical correlations are used to determine various parameters
such as Reynolds number, Nusselt number, heat transfer coefficient etc. The readings and observations are taken
prior to calculation of above mentioned parameters In present work, experimentation is done for single-phase
water to water tube in tube heat exchanger with threaded and non threaded inner pipe. This analytical work is
further studied in detail and presented.
Manufacturing and Comparative Analysis ...
80
results And Discussions
Effect of flow rate on Nusselt Number
Fig 2.Variation of inner tube Nusselt Number with Threaded and Straight inner
tube flow rate for cold 200 LPH
Fig.3.Variation of inner tube Nusselt Number with Threaded and Straight inner
tube flow rate for cold 300 LPH
Fig.4.Variation of inner tube Nusselt Number with Threaded and Straight inner
tube flow rate for cold 400 LPH
Manufacturing and Comparative Analysis ...
81
Effect of Nusselt Number on inner tube side Reynolds Number for different configurations of the inner tube
(threaded and Straight)
Fig 5.Variation of inner tube Nusselt Number with Reynolds number for threaded
and Straight tube for cold 200 LPH.
Fig 6. Variation of inner tube Nusselt Number with Reynolds number for
threaded and Straight tube for cold 300 LPH
Manufacturing and Comparative Analysis ...
82
Fig 7. Variation of inner tube Nusselt Number with Reynolds number for
threaded and Straight tube for cold 400 LPH
Effect of Convection coefficient for different configurations of the inner tube (threaded and Straight)
Fig.8 Variation of inner tube Convection coefficient with Threaded and
Straight inner tube flow rate for cold 200 LPH
Manufacturing and Comparative Analysis ...
83
Fig 9.Variation of inner tube Convection coefficient with Threaded and
Straight innertube flow rate for cold 300 LPH
F
Fig.10.Variation of inner tube Convection coefficient with Threaded and
Straight inner tube flow rate for cold 400 LPH
Qavgfor different configurations of the inner tube (threaded and Straight)
Fig 11.Variation of Qavg with Threaded and Straight inner tube flow rate for
cold 200 LPH
Manufacturing and Comparative Analysis ...
84
Fig 12.Variation of Qavg with Threaded and Straight inner tube flow rate for
cold 300 LPH
Fig.13.Variation of Qavg with Threaded and Straight inner tube flow rate for
cold 400 LPH
1. It is observed from the graph that the heat transfer rates of threaded pipe are more as compared to non-
threaded pipe, keeping the cold flow rate (LPH) constant.
2. It is also observed from the graphs, that heat transfer rate for threaded pipe is more than non-threaded pipe for
respective cold mass flow rate.
3. It is clear that the Nusselt Number of inner tube increases with increasing flow rate of water through inner
tube.
IV. CONCLUSIONS
An experimental study has been performed to investigate the performance (pressure drop and Nu
characteristic) for the two configurations of inner tube in the single phase water-to-water tube in tube heat
exchanger (TTHE) i.e. threaded; non threaded. A two to four times more heat transfer enhancement is observed
experimentally for the aforesaid heat exchanger with increased pumping power requirement of twice or thrice.
Thus this work concludes that significant heat transfer enhancement is achieved for the threaded inner tube in
TTHE. The work can be extended further for heavy heat duty industrial applications with wide operating
conditions, different fluids and more precise instrumentation, provided that time and money are not constraints.
Manufacturing and Comparative Analysis ...
85
REFERENCES
[1] A.E. Bergles, “The imperative to enhance heat transfer”, Energy Conservation Through Heat Transfer Enhancement of Heat
Exchangers, Turkey, 1998, pp. 547-563.
[2] C.A. Balaras, “A review of augmentation techniques for heat transfer surfaces in single-phase heat exchangers”, Energy Conversion
and Management, Vol. 15, 1990, pp. 899–906
[3] Wolverine INC “ Wolverine Tube heat transfer data book”
[4] Yonghan Kim, Yongchan Kim “Heat transfer characteristics of flat plate finned-tube heat exchangers with large fin pitch”, Vol. 1 26
January 2005
[5] HT 307 “Finned tube heat exchanger” .
[6] Creed Taylor “Measurement of finned-tube heat exchanger performance”.
[7] Friedrich Frass “Principles of finned-tube heat exchanger design for enhanced heat transfer”
[8] J.A.Livingstone“Effective Heat Transfer Enhancement in Finned Tube Heat Exchanger with different Fin Profiles” Vol.2, Issue 2 ,
2013, pp:83-87
[9] Shiv Kumar Rathor “Comparative Analysis of Finned Tube and Bared Tube Type Shell and Tube Heat Exchanger” Vol. 2, Issue 1,
July 2012
[10] Hamid Nabati “Optimal pin fin heat exchanger surface” 2008
[11] A. D.Kadam“ Perfomance simulation of fin and tube heat exchanger” IJESR Vol.2, Issue 10, 2012
[12] Sandeep R Desai “Determination of Modal parameters for finned tube heat exchanger tubes of various configurations” UJME 2013
[13] Kevin Lunsford “ Increasing heat exchanger performance” Bryan research and engineering, inc. 2006
[14] K P M Wipplinger “Stainless steel finned tube heat exchanger design for waste heat recovery”
[15] M. V. Ghori “Numerical Analysis of Tube-fin Heat Exchanger using Fluent”
[16] Jiin-YuhJang”Optimum louver angle design for a louvered fin heat exchanger” IJPS vol.6 pp 6422-6438
[17] AlaHasan “Performance investigation of plain and finned tube evaporatively cooled heat exchangers”
[18] Chi-Chuan Wang “Recent advances in fin-and-tube heat exchanger” Vol.19, 2011, pp.291-301
[19] S. F Tsai “A comparison study on fin surfaces in finned-tube heat exchangers” IJNM Vol.9, 1999 pp.92-106
[20] W.K. Ding, J.F. Fan, Y.L. He, W.Q. Tao, Y.X. Zheng, Y.F. Gao, J. Song “A general simulation model for performance prediction of
plate fin-and-tube heat exchanger with complex circuit configuration” Science Direct, 2011, pp.3106-3116.
[21] R. K. Shah* and D. R Sekulib,University of Kentucky
[22] PiotrWais,“Fin-Tube Heat Exchanger Optimization”PiotrWais,Cracow University of Technology, Department of Thermal Power
Engineering, Poland
[23] Kevin M. Lunsford, “Increasing Heat Exchanger Performance”Bryan Research & Engineering, Inc., Bryan, Texas
[24] Comparative Analysis of Finned Tube and Bared Tube Type Shell and Tube Heat Exchanger Shiv Kumar Rathore, AjeetBergaley
[25] M.R.Jafari Nasr and A. T. Zoghi “Full Analysis Of Low Finned Tube Heat Exchangers”,Research Institute of Petroleum Industry
(RIPI), National Iranian Oil Company (NIOC)

Weitere ähnliche Inhalte

Was ist angesagt?

FLUID FLOW ANALYSIS IN AIR DUCT FLOW WITH AND WITHOUT INTERNAL THREADS USING ...
FLUID FLOW ANALYSIS IN AIR DUCT FLOW WITH AND WITHOUT INTERNAL THREADS USING ...FLUID FLOW ANALYSIS IN AIR DUCT FLOW WITH AND WITHOUT INTERNAL THREADS USING ...
FLUID FLOW ANALYSIS IN AIR DUCT FLOW WITH AND WITHOUT INTERNAL THREADS USING ...
IAEME Publication
 
Comparative Study and Analysis between Helical Coil and Straight Tube Heat Ex...
Comparative Study and Analysis between Helical Coil and Straight Tube Heat Ex...Comparative Study and Analysis between Helical Coil and Straight Tube Heat Ex...
Comparative Study and Analysis between Helical Coil and Straight Tube Heat Ex...
IJERA Editor
 
EXPERIMENTAL STUDY ON THE ANALYSIS OF HEAT ENHANCEMENT IN CORRUGATED TWISTED ...
EXPERIMENTAL STUDY ON THE ANALYSIS OF HEAT ENHANCEMENT IN CORRUGATED TWISTED ...EXPERIMENTAL STUDY ON THE ANALYSIS OF HEAT ENHANCEMENT IN CORRUGATED TWISTED ...
EXPERIMENTAL STUDY ON THE ANALYSIS OF HEAT ENHANCEMENT IN CORRUGATED TWISTED ...
P singh
 
A Review on Study of Heat Transfer Analysis of Helical Coil Heat Exchangers
A Review on Study of Heat Transfer Analysis of Helical Coil Heat ExchangersA Review on Study of Heat Transfer Analysis of Helical Coil Heat Exchangers
A Review on Study of Heat Transfer Analysis of Helical Coil Heat Exchangers
ijtsrd
 

Was ist angesagt? (16)

FLUID FLOW ANALYSIS IN AIR DUCT FLOW WITH AND WITHOUT INTERNAL THREADS USING ...
FLUID FLOW ANALYSIS IN AIR DUCT FLOW WITH AND WITHOUT INTERNAL THREADS USING ...FLUID FLOW ANALYSIS IN AIR DUCT FLOW WITH AND WITHOUT INTERNAL THREADS USING ...
FLUID FLOW ANALYSIS IN AIR DUCT FLOW WITH AND WITHOUT INTERNAL THREADS USING ...
 
IRJET- Study of Heat Transfer Characteristics for the Flow of Air over a Heat...
IRJET- Study of Heat Transfer Characteristics for the Flow of Air over a Heat...IRJET- Study of Heat Transfer Characteristics for the Flow of Air over a Heat...
IRJET- Study of Heat Transfer Characteristics for the Flow of Air over a Heat...
 
Comparison of Shell and Tube Heat Exchanger using Theoretical Methods, HTRI, ...
Comparison of Shell and Tube Heat Exchanger using Theoretical Methods, HTRI, ...Comparison of Shell and Tube Heat Exchanger using Theoretical Methods, HTRI, ...
Comparison of Shell and Tube Heat Exchanger using Theoretical Methods, HTRI, ...
 
IRJET-Numerical Investigation of Heat Performance Enhancement for a Double-Pi...
IRJET-Numerical Investigation of Heat Performance Enhancement for a Double-Pi...IRJET-Numerical Investigation of Heat Performance Enhancement for a Double-Pi...
IRJET-Numerical Investigation of Heat Performance Enhancement for a Double-Pi...
 
Comparative Study and Analysis between Helical Coil and Straight Tube Heat Ex...
Comparative Study and Analysis between Helical Coil and Straight Tube Heat Ex...Comparative Study and Analysis between Helical Coil and Straight Tube Heat Ex...
Comparative Study and Analysis between Helical Coil and Straight Tube Heat Ex...
 
Analysis of Heat Generation in Double Pipe Heat Exchanger: An Experimental Ev...
Analysis of Heat Generation in Double Pipe Heat Exchanger: An Experimental Ev...Analysis of Heat Generation in Double Pipe Heat Exchanger: An Experimental Ev...
Analysis of Heat Generation in Double Pipe Heat Exchanger: An Experimental Ev...
 
IRJET- Experimental Analysis of Convective Heat Transfer Augmentation of Bi-M...
IRJET- Experimental Analysis of Convective Heat Transfer Augmentation of Bi-M...IRJET- Experimental Analysis of Convective Heat Transfer Augmentation of Bi-M...
IRJET- Experimental Analysis of Convective Heat Transfer Augmentation of Bi-M...
 
CFD Analysis of Concentric Tube Heat Exchanger Using Twisted Tapes
CFD Analysis of Concentric Tube Heat Exchanger Using Twisted TapesCFD Analysis of Concentric Tube Heat Exchanger Using Twisted Tapes
CFD Analysis of Concentric Tube Heat Exchanger Using Twisted Tapes
 
Computational Fluid Dynamic Analysis for Optimization of Helical Coil Heat Ex...
Computational Fluid Dynamic Analysis for Optimization of Helical Coil Heat Ex...Computational Fluid Dynamic Analysis for Optimization of Helical Coil Heat Ex...
Computational Fluid Dynamic Analysis for Optimization of Helical Coil Heat Ex...
 
EXPERIMENTAL STUDY ON THE ANALYSIS OF HEAT ENHANCEMENT IN CORRUGATED TWISTED ...
EXPERIMENTAL STUDY ON THE ANALYSIS OF HEAT ENHANCEMENT IN CORRUGATED TWISTED ...EXPERIMENTAL STUDY ON THE ANALYSIS OF HEAT ENHANCEMENT IN CORRUGATED TWISTED ...
EXPERIMENTAL STUDY ON THE ANALYSIS OF HEAT ENHANCEMENT IN CORRUGATED TWISTED ...
 
E351923
E351923E351923
E351923
 
Comparative Study of ECONOMISER Using the CFD Analysis
Comparative Study of ECONOMISER Using the CFD Analysis Comparative Study of ECONOMISER Using the CFD Analysis
Comparative Study of ECONOMISER Using the CFD Analysis
 
Experimental Study of Heat Transfer Enhancement of Pipe-inPipe Helical Coil H...
Experimental Study of Heat Transfer Enhancement of Pipe-inPipe Helical Coil H...Experimental Study of Heat Transfer Enhancement of Pipe-inPipe Helical Coil H...
Experimental Study of Heat Transfer Enhancement of Pipe-inPipe Helical Coil H...
 
IRJET- Numerical Analysis for Effect of Different Length Combination of Turbu...
IRJET- Numerical Analysis for Effect of Different Length Combination of Turbu...IRJET- Numerical Analysis for Effect of Different Length Combination of Turbu...
IRJET- Numerical Analysis for Effect of Different Length Combination of Turbu...
 
A Review on Study of Heat Transfer Analysis of Helical Coil Heat Exchangers
A Review on Study of Heat Transfer Analysis of Helical Coil Heat ExchangersA Review on Study of Heat Transfer Analysis of Helical Coil Heat Exchangers
A Review on Study of Heat Transfer Analysis of Helical Coil Heat Exchangers
 
Computational Performance Analysis of Heat Sink with Pin Fin for Various Surf...
Computational Performance Analysis of Heat Sink with Pin Fin for Various Surf...Computational Performance Analysis of Heat Sink with Pin Fin for Various Surf...
Computational Performance Analysis of Heat Sink with Pin Fin for Various Surf...
 

Andere mochten auch

1.arafat ahmed bhuiyan 1 12
1.arafat ahmed bhuiyan 1 121.arafat ahmed bhuiyan 1 12
1.arafat ahmed bhuiyan 1 12
Alexander Decker
 

Andere mochten auch (7)

1.arafat ahmed bhuiyan 1 12
1.arafat ahmed bhuiyan 1 121.arafat ahmed bhuiyan 1 12
1.arafat ahmed bhuiyan 1 12
 
30120140507001
3012014050700130120140507001
30120140507001
 
30120140505015 2
30120140505015 230120140505015 2
30120140505015 2
 
Single-Phase Heat Transfer and Pressure Drop In the Micro-Fin Tube with Coil...
Single-Phase Heat Transfer and Pressure Drop In the Micro-Fin  Tube with Coil...Single-Phase Heat Transfer and Pressure Drop In the Micro-Fin  Tube with Coil...
Single-Phase Heat Transfer and Pressure Drop In the Micro-Fin Tube with Coil...
 
Alpema standards9
Alpema standards9Alpema standards9
Alpema standards9
 
kushal khadakkar
kushal khadakkarkushal khadakkar
kushal khadakkar
 
Compact heat exchangers
Compact heat exchangersCompact heat exchangers
Compact heat exchangers
 

Ähnlich wie J047077085

Biodiesel, Brake thermal efficiency, Brake specific fuel consumption Honge, J...
Biodiesel, Brake thermal efficiency, Brake specific fuel consumption Honge, J...Biodiesel, Brake thermal efficiency, Brake specific fuel consumption Honge, J...
Biodiesel, Brake thermal efficiency, Brake specific fuel consumption Honge, J...
IJMER
 
CFD Analysis for Heat Transfer Enhancement of a Corrugated Plate Heat Exchang...
CFD Analysis for Heat Transfer Enhancement of a Corrugated Plate Heat Exchang...CFD Analysis for Heat Transfer Enhancement of a Corrugated Plate Heat Exchang...
CFD Analysis for Heat Transfer Enhancement of a Corrugated Plate Heat Exchang...
ijtsrd
 
Numerical Investigation of Heat Transfer from Two Different Cylinders in Tand...
Numerical Investigation of Heat Transfer from Two Different Cylinders in Tand...Numerical Investigation of Heat Transfer from Two Different Cylinders in Tand...
Numerical Investigation of Heat Transfer from Two Different Cylinders in Tand...
IJERA Editor
 

Ähnlich wie J047077085 (20)

CFD Analysis of Plate Fin Tube Heat Exchanger for Various Fin Inclinations
CFD Analysis of Plate Fin Tube Heat Exchanger for Various Fin InclinationsCFD Analysis of Plate Fin Tube Heat Exchanger for Various Fin Inclinations
CFD Analysis of Plate Fin Tube Heat Exchanger for Various Fin Inclinations
 
Heat transfer enhancement_fusion reactor.pdf
Heat transfer enhancement_fusion reactor.pdfHeat transfer enhancement_fusion reactor.pdf
Heat transfer enhancement_fusion reactor.pdf
 
Analysis of Double Pipe Heat Exchanger With Helical Fins
Analysis of Double Pipe Heat Exchanger With Helical FinsAnalysis of Double Pipe Heat Exchanger With Helical Fins
Analysis of Double Pipe Heat Exchanger With Helical Fins
 
Biodiesel, Brake thermal efficiency, Brake specific fuel consumption Honge, J...
Biodiesel, Brake thermal efficiency, Brake specific fuel consumption Honge, J...Biodiesel, Brake thermal efficiency, Brake specific fuel consumption Honge, J...
Biodiesel, Brake thermal efficiency, Brake specific fuel consumption Honge, J...
 
E351923
E351923E351923
E351923
 
E351923
E351923E351923
E351923
 
E351923
E351923E351923
E351923
 
30120140507001
3012014050700130120140507001
30120140507001
 
Numerical Analysis of Header Configuration of the Plate-Fin Heat Exchanger
Numerical Analysis of Header Configuration of the Plate-Fin  Heat ExchangerNumerical Analysis of Header Configuration of the Plate-Fin  Heat Exchanger
Numerical Analysis of Header Configuration of the Plate-Fin Heat Exchanger
 
CFD Analysis of Heat Transfer in Helical Coil
CFD Analysis of Heat Transfer in Helical CoilCFD Analysis of Heat Transfer in Helical Coil
CFD Analysis of Heat Transfer in Helical Coil
 
Irjet v4 i12326Effect of External Threaded Inside Tube on Heat Transfer Rate ...
Irjet v4 i12326Effect of External Threaded Inside Tube on Heat Transfer Rate ...Irjet v4 i12326Effect of External Threaded Inside Tube on Heat Transfer Rate ...
Irjet v4 i12326Effect of External Threaded Inside Tube on Heat Transfer Rate ...
 
A comprehensive review on Heat and fluid flow in Baffled Pipe/Channel
A comprehensive review on Heat and fluid flow in Baffled Pipe/ChannelA comprehensive review on Heat and fluid flow in Baffled Pipe/Channel
A comprehensive review on Heat and fluid flow in Baffled Pipe/Channel
 
CFD Analysis for Heat Transfer Enhancement of a Corrugated Plate Heat Exchang...
CFD Analysis for Heat Transfer Enhancement of a Corrugated Plate Heat Exchang...CFD Analysis for Heat Transfer Enhancement of a Corrugated Plate Heat Exchang...
CFD Analysis for Heat Transfer Enhancement of a Corrugated Plate Heat Exchang...
 
Review Over The Effects Of Baffle Orientation And Shape Factor Over Pressure ...
Review Over The Effects Of Baffle Orientation And Shape Factor Over Pressure ...Review Over The Effects Of Baffle Orientation And Shape Factor Over Pressure ...
Review Over The Effects Of Baffle Orientation And Shape Factor Over Pressure ...
 
Numerical Investigation of Heat Transfer from Two Different Cylinders in Tand...
Numerical Investigation of Heat Transfer from Two Different Cylinders in Tand...Numerical Investigation of Heat Transfer from Two Different Cylinders in Tand...
Numerical Investigation of Heat Transfer from Two Different Cylinders in Tand...
 
THE EFFECT OF GEOMETRICAL PARAMETERS ON HEAT TRANSFER AND HYDRO DYNAMICAL CHA...
THE EFFECT OF GEOMETRICAL PARAMETERS ON HEAT TRANSFER AND HYDRO DYNAMICAL CHA...THE EFFECT OF GEOMETRICAL PARAMETERS ON HEAT TRANSFER AND HYDRO DYNAMICAL CHA...
THE EFFECT OF GEOMETRICAL PARAMETERS ON HEAT TRANSFER AND HYDRO DYNAMICAL CHA...
 
IRJET- Numerical Investigation of Heat Transfer Enhancement in Circular Pipe ...
IRJET- Numerical Investigation of Heat Transfer Enhancement in Circular Pipe ...IRJET- Numerical Investigation of Heat Transfer Enhancement in Circular Pipe ...
IRJET- Numerical Investigation of Heat Transfer Enhancement in Circular Pipe ...
 
IRJET- Effect of Wavy Tube on Heat Transfer in a Concentric Tube Heat Exch...
IRJET- 	  Effect of Wavy Tube on Heat Transfer in a Concentric Tube Heat Exch...IRJET- 	  Effect of Wavy Tube on Heat Transfer in a Concentric Tube Heat Exch...
IRJET- Effect of Wavy Tube on Heat Transfer in a Concentric Tube Heat Exch...
 
Effect of Wavy Tube on Heat Transfer in a Concentric Tube Heat Exchanger: A R...
Effect of Wavy Tube on Heat Transfer in a Concentric Tube Heat Exchanger: A R...Effect of Wavy Tube on Heat Transfer in a Concentric Tube Heat Exchanger: A R...
Effect of Wavy Tube on Heat Transfer in a Concentric Tube Heat Exchanger: A R...
 
A Review on Enhancement of Heat Transfer Rate by Various Passive Methods
A Review on Enhancement of Heat Transfer Rate by Various Passive MethodsA Review on Enhancement of Heat Transfer Rate by Various Passive Methods
A Review on Enhancement of Heat Transfer Rate by Various Passive Methods
 

Mehr von inventy

Experimental Investigation of a Household Refrigerator Using Evaporative-Cool...
Experimental Investigation of a Household Refrigerator Using Evaporative-Cool...Experimental Investigation of a Household Refrigerator Using Evaporative-Cool...
Experimental Investigation of a Household Refrigerator Using Evaporative-Cool...
inventy
 
Development and Application of a Failure Monitoring System by Using the Vibra...
Development and Application of a Failure Monitoring System by Using the Vibra...Development and Application of a Failure Monitoring System by Using the Vibra...
Development and Application of a Failure Monitoring System by Using the Vibra...
inventy
 
The Management of Protected Areas in Serengeti Ecosystem: A Case Study of Iko...
The Management of Protected Areas in Serengeti Ecosystem: A Case Study of Iko...The Management of Protected Areas in Serengeti Ecosystem: A Case Study of Iko...
The Management of Protected Areas in Serengeti Ecosystem: A Case Study of Iko...
inventy
 
Removal of Chromium (VI) From Aqueous Solutions Using Discarded Solanum Tuber...
Removal of Chromium (VI) From Aqueous Solutions Using Discarded Solanum Tuber...Removal of Chromium (VI) From Aqueous Solutions Using Discarded Solanum Tuber...
Removal of Chromium (VI) From Aqueous Solutions Using Discarded Solanum Tuber...
inventy
 
Choice of Numerical Integration Method for Wind Time History Analysis of Tall...
Choice of Numerical Integration Method for Wind Time History Analysis of Tall...Choice of Numerical Integration Method for Wind Time History Analysis of Tall...
Choice of Numerical Integration Method for Wind Time History Analysis of Tall...
inventy
 

Mehr von inventy (20)

Experimental Investigation of a Household Refrigerator Using Evaporative-Cool...
Experimental Investigation of a Household Refrigerator Using Evaporative-Cool...Experimental Investigation of a Household Refrigerator Using Evaporative-Cool...
Experimental Investigation of a Household Refrigerator Using Evaporative-Cool...
 
Copper Strip Corrossion Test in Various Aviation Fuels
Copper Strip Corrossion Test in Various Aviation FuelsCopper Strip Corrossion Test in Various Aviation Fuels
Copper Strip Corrossion Test in Various Aviation Fuels
 
Additional Conservation Laws for Two-Velocity Hydrodynamics Equations with th...
Additional Conservation Laws for Two-Velocity Hydrodynamics Equations with th...Additional Conservation Laws for Two-Velocity Hydrodynamics Equations with th...
Additional Conservation Laws for Two-Velocity Hydrodynamics Equations with th...
 
Comparative Study of the Quality of Life, Quality of Work Life and Organisati...
Comparative Study of the Quality of Life, Quality of Work Life and Organisati...Comparative Study of the Quality of Life, Quality of Work Life and Organisati...
Comparative Study of the Quality of Life, Quality of Work Life and Organisati...
 
A Study of Automated Decision Making Systems
A Study of Automated Decision Making SystemsA Study of Automated Decision Making Systems
A Study of Automated Decision Making Systems
 
Crystallization of L-Glutamic Acid: Mechanism of Heterogeneous β -Form Nuclea...
Crystallization of L-Glutamic Acid: Mechanism of Heterogeneous β -Form Nuclea...Crystallization of L-Glutamic Acid: Mechanism of Heterogeneous β -Form Nuclea...
Crystallization of L-Glutamic Acid: Mechanism of Heterogeneous β -Form Nuclea...
 
Evaluation of Damage by the Reliability of the Traction Test on Polymer Test ...
Evaluation of Damage by the Reliability of the Traction Test on Polymer Test ...Evaluation of Damage by the Reliability of the Traction Test on Polymer Test ...
Evaluation of Damage by the Reliability of the Traction Test on Polymer Test ...
 
Application of Kennelly’model of Running Performances to Elite Endurance Runn...
Application of Kennelly’model of Running Performances to Elite Endurance Runn...Application of Kennelly’model of Running Performances to Elite Endurance Runn...
Application of Kennelly’model of Running Performances to Elite Endurance Runn...
 
Development and Application of a Failure Monitoring System by Using the Vibra...
Development and Application of a Failure Monitoring System by Using the Vibra...Development and Application of a Failure Monitoring System by Using the Vibra...
Development and Application of a Failure Monitoring System by Using the Vibra...
 
The Management of Protected Areas in Serengeti Ecosystem: A Case Study of Iko...
The Management of Protected Areas in Serengeti Ecosystem: A Case Study of Iko...The Management of Protected Areas in Serengeti Ecosystem: A Case Study of Iko...
The Management of Protected Areas in Serengeti Ecosystem: A Case Study of Iko...
 
Size distribution and biometric relationships of little tunny Euthynnus allet...
Size distribution and biometric relationships of little tunny Euthynnus allet...Size distribution and biometric relationships of little tunny Euthynnus allet...
Size distribution and biometric relationships of little tunny Euthynnus allet...
 
Removal of Chromium (VI) From Aqueous Solutions Using Discarded Solanum Tuber...
Removal of Chromium (VI) From Aqueous Solutions Using Discarded Solanum Tuber...Removal of Chromium (VI) From Aqueous Solutions Using Discarded Solanum Tuber...
Removal of Chromium (VI) From Aqueous Solutions Using Discarded Solanum Tuber...
 
Effect of Various External and Internal Factors on the Carrier Mobility in n-...
Effect of Various External and Internal Factors on the Carrier Mobility in n-...Effect of Various External and Internal Factors on the Carrier Mobility in n-...
Effect of Various External and Internal Factors on the Carrier Mobility in n-...
 
Transient flow analysis for horizontal axial upper-wind turbine
Transient flow analysis for horizontal axial upper-wind turbineTransient flow analysis for horizontal axial upper-wind turbine
Transient flow analysis for horizontal axial upper-wind turbine
 
Choice of Numerical Integration Method for Wind Time History Analysis of Tall...
Choice of Numerical Integration Method for Wind Time History Analysis of Tall...Choice of Numerical Integration Method for Wind Time History Analysis of Tall...
Choice of Numerical Integration Method for Wind Time History Analysis of Tall...
 
Impacts of Demand Side Management on System Reliability Evaluation
Impacts of Demand Side Management on System Reliability EvaluationImpacts of Demand Side Management on System Reliability Evaluation
Impacts of Demand Side Management on System Reliability Evaluation
 
Reliability Evaluation of Riyadh System Incorporating Renewable Generation
Reliability Evaluation of Riyadh System Incorporating Renewable GenerationReliability Evaluation of Riyadh System Incorporating Renewable Generation
Reliability Evaluation of Riyadh System Incorporating Renewable Generation
 
The effect of reduced pressure acetylene plasma treatment on physical charact...
The effect of reduced pressure acetylene plasma treatment on physical charact...The effect of reduced pressure acetylene plasma treatment on physical charact...
The effect of reduced pressure acetylene plasma treatment on physical charact...
 
Experimental Investigation of Mini Cooler cum Freezer
Experimental Investigation of Mini Cooler cum FreezerExperimental Investigation of Mini Cooler cum Freezer
Experimental Investigation of Mini Cooler cum Freezer
 
Growth and Magnetic properties of MnGeP2 thin films
Growth and Magnetic properties of MnGeP2 thin filmsGrowth and Magnetic properties of MnGeP2 thin films
Growth and Magnetic properties of MnGeP2 thin films
 

Kürzlich hochgeladen

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
ssuser89054b
 
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar ≼🔝 Delhi door step de...
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar  ≼🔝 Delhi door step de...Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar  ≼🔝 Delhi door step de...
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar ≼🔝 Delhi door step de...
9953056974 Low Rate Call Girls In Saket, Delhi NCR
 
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
dharasingh5698
 
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
Christo Ananth
 
AKTU Computer Networks notes --- Unit 3.pdf
AKTU Computer Networks notes ---  Unit 3.pdfAKTU Computer Networks notes ---  Unit 3.pdf
AKTU Computer Networks notes --- Unit 3.pdf
ankushspencer015
 
notes on Evolution Of Analytic Scalability.ppt
notes on Evolution Of Analytic Scalability.pptnotes on Evolution Of Analytic Scalability.ppt
notes on Evolution Of Analytic Scalability.ppt
MsecMca
 
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night StandCall Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
amitlee9823
 

Kürzlich hochgeladen (20)

(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7
(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7
(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7
 
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
 
PVC VS. FIBERGLASS (FRP) GRAVITY SEWER - UNI BELL
PVC VS. FIBERGLASS (FRP) GRAVITY SEWER - UNI BELLPVC VS. FIBERGLASS (FRP) GRAVITY SEWER - UNI BELL
PVC VS. FIBERGLASS (FRP) GRAVITY SEWER - UNI BELL
 
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
 
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar ≼🔝 Delhi door step de...
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar  ≼🔝 Delhi door step de...Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar  ≼🔝 Delhi door step de...
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar ≼🔝 Delhi door step de...
 
UNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its PerformanceUNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its Performance
 
(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7
(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7
(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7
 
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
 
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete RecordCCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
 
data_management_and _data_science_cheat_sheet.pdf
data_management_and _data_science_cheat_sheet.pdfdata_management_and _data_science_cheat_sheet.pdf
data_management_and _data_science_cheat_sheet.pdf
 
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
 
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
 
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
 
AKTU Computer Networks notes --- Unit 3.pdf
AKTU Computer Networks notes ---  Unit 3.pdfAKTU Computer Networks notes ---  Unit 3.pdf
AKTU Computer Networks notes --- Unit 3.pdf
 
chapter 5.pptx: drainage and irrigation engineering
chapter 5.pptx: drainage and irrigation engineeringchapter 5.pptx: drainage and irrigation engineering
chapter 5.pptx: drainage and irrigation engineering
 
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptxBSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
 
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...
 
Unit 1 - Soil Classification and Compaction.pdf
Unit 1 - Soil Classification and Compaction.pdfUnit 1 - Soil Classification and Compaction.pdf
Unit 1 - Soil Classification and Compaction.pdf
 
notes on Evolution Of Analytic Scalability.ppt
notes on Evolution Of Analytic Scalability.pptnotes on Evolution Of Analytic Scalability.ppt
notes on Evolution Of Analytic Scalability.ppt
 
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night StandCall Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
 

J047077085

  • 1. Research Inventy: International Journal of Engineering And Science Vol.4, Issue 7 (July 2014), PP 77-85 Issn (e): 2278-4721, Issn (p):2319-6483, www.researchinventy.com 77 Manufacturing and Comparative Analysis of Threaded Tube Heat Exchanger with Straight Tube Heat Exchanger Prof.N.B.Totala1 , Prof.V.P.Desai2 , Pratik Gawade3 , Nikhil Kakade4 ,Anant Paralkar5 , ArpitBanerjee6 , Shreenath Agarwal7 1,2 (Assistant Professor, Department of Mechanical Engineering, MIT Academy of Engineering,Alandi (D), Pune, Maharashtra, 412105) 3,4,5,6 (Department of Mechanical Engineering, MIT Academy of Engineering, Alandi(D), Pune, Maharashtra, 412105) 7 (Assistant Manager, Production G Series, Greaves Cotton Ltd, Diesel Engine Unit, Akurdi.Pune.) ABSTRACT: To intensify the heat transfer from the heat exchanger surface to fluid, it is possible to increase convection coefficient, widen temperature difference between surface and fluid or increase the surface area across which convection occurs. Extended surfaces, in the form of longitudinal or radial fins are common in applications where the need to enhance the heat transfer between a surface and an adjacent fluid exists. Fins are commonly used in extended surface exchangers. To minimize the size of heat exchangers, fins are used to increase the surface area and the heat transfer rate between the heat exchanger surface and the surroundings. Both the conduction through the fin cross section and the convection over the fin surface area take place in and around the fin, the temperature value is limited by the type of material and production technique. Due to all above, finned tube heat exchangers are used in different thermal systems for applications where heat energy is exchanged between different media. Applications range from very large to the small scale (tubes in heat exchangers, the temperature control of electronic components).The subject, which is investigated in this paper, is concentrated on increasing heat transfer rate by provided extended surfaces like threads. By providing threads, heat transfer area increases and it leads to better heat transfer due to turbulence. KEYWORDS: Heat transfer co-efficient, Nusselt number, Reynolds number, Thermal conductivity, I. INTRODUCTION The performance of a conventional heat exchanger, which is an essential unit in heat extraction and recovery systems, can be substantially improved by a number of augmentation techniques. Common thermal- hydraulic goals are to reduce the size of heat exchanger required for specified heat duty, to upgrade the capacity of an existing heat exchanger, to reduce the approach temperature difference for the process streams, or to reduce the pumping power. A preferred approach to the problem of increasing heat exchanger effectiveness, while maintaining minimum heat exchanger size and operational cost, is to increase the heat transfer exchange rate.The addition of fins reduces the thermal resistance on that side and thereby increases the net heat transfer from/to the surface for thesame temperature difference. The heat transfer coefficient can also be higher for fins.To develop the correlations for forced convection for the inner pipe in tube in tube heat exchanger having threaded shape using experimental and numerical techniques. This geometry is expected to augment heat transfer for vortex shedding and turbulence because of internal curvatures and enhanced area available for heat transfer.In order to do so, the experiments employ tube in tube heat exchanger with two configurations of the inner tube namely straight smooth tube and threaded tube. The experimentation will be conducted for the Reynolds number in turbulent region ranging from 6000 to 25,000. A.E. Bergles, [1] showed that heat energy is conserved by heat transfer enhancement.C.A. Balaras, [2] reviewed of augmentation techniques for heat transfer surfaces in single-phase heat exchangers.Wolverine INC [3] An engineering data book was referred to have a insight for enhanced heat exchangers. Kim[4]Studied the characteristics of flat plate finned-tube heat exchangers with large fin pitch. In this study, 22 heat exchangers were tested with a variation of fin pitch, number of tube row, and tube alignment. The air-side heat transfer coefficient decreased with a reduction of the fin pitch and an increase of the number of tube row. The reduction in the heat transfer coefficient of the four-row heat exchanger coil was approximately 10% as the fin pitch decreased from 15.0 to 7.5 mm over the Reynolds number range of 500–900 that was calculated based on the tube diameter. For all fin pitches, the heat transfer coefficient decreased as the number of tube row increased from 1 to 4. The staggered tube alignment improved heat transfer performance more than 10% compared to the
  • 2. Manufacturing and Comparative Analysis ... 78 inline tube alignment. A heat transfer correlation was developed from the measured data for flat plate finned- tubes with large fin pitch. The correlation yielded good predictions of the measured data.HT-307[5] was referred to determine the efficiency of given longitudinal /pin fin and compare it with the theoretical value for the given fin. Creed Taylor [6] researched on types of heat exchangers used in refrigeration system and its environmental impact. Friedrich Frass[7] studied principles in heat exchanger designing and constructing heat exchangers with transverse finned tubes in cross-flow, it is necessary to know correlations for calculating heat transfer and pressure drop. In addition to the common use of the Reynolds and Nusselt groups of dimensionless numbers, heat conduction in the fins also has to be accounted for calculating the heat transfer. A reduction coefficient termed “fin efficiency” is therefore introduced, by which the actual heat transfer coefficient is multiplied in order to get the apparent heat transfer coefficient. J.A. Livinstone [8] studied heat transfer enhancement with different types of fins and studied the heat transfer rates. Shiv Kumar Rathor [9] identified the advantages of low-finned tube Heat Exchangers over Plain tube (Bare Tube) units. To use finned tubes to advantage in this application, several technical issues were to be addressed. Shell side and tube side pressure, cost, weight and size of heat exchanger. Hamid Nabati[10] studied on results of heat transfer rates and pressure drop with different types of fins. The heat exchanger used for this research consists of a rectangular duct fitted with different shape pin fins, and is heated from the lower plate. The pin shape and the compact heat exchanger (CHE) configuration were numerically studied to maximize the heat transfer and minimize the pressure drop across the heat exchanger. A.D.Kadam[11] carried out simulation of fin and tube type heat exchanger with the help of computer simulation software. Sandeep R. Desai [12]carried out analysis of fluid elastic vibrations of heat exchanger tubes and its determination of modal parameters (natural frequency and damping ratios) of the tubes. Kevin Lunsford [13] published a technical paper on how to improve the heat exchanger performance with simulation programs commercial feasibility etc.K P M Wipplinger [14] designed a stainless steel finned tube heat exchanger. M V Ghori [15] experimented three- dimensional CFD simulation and carried out investigation on heat transfer and fluid flow characteristics of two- row plain Tube and Fin heat exchanger using FLUENT software. Jiin-Yuh Jang [16] this paper suggests a method for finding the optimal louver angle of a fin heat exchanger by use of simplified conjugate-gradient method (SCGM) and a three-dimensional computational fluid dynamics model. AlaHasan [17] conducted the performance of two evaporatively cooled heat exchangers is investigated under similar operating conditions of air flow rates and inlet hot water temperatures. The heat exchangers are plain and plate-finned circular tube types which occupy the same volume. Chi-ChuanWang[18] the objective of this paper is to summarize the recent progress of fin pattern designs. Some of the designs are from the applied patents and some are from the recent literatures. The fin patterns include interrupted surfaces, enhanced wavy and the vortex generators. Benefits and the associated constraints of these designs are discussed. S.F Tsai [19]A three-dimensional numerical study was conducted to assess the heat transfer performance of extended fins in a two-row finned tube heat exchanger. Fins under investigation were plane and slit types. A finite volume discretization method and a SIMPLE-based solution algorithm were, respectively, applied to working differential equations and their discrete counterparts to compute the gas velocities and pressure. W. K. Ding [20] .A circuit data structure (circuit connection network) for a general description of different circuit configurations in computer programs is presented. On basis of this data structure, a general tube-by-tube simulation model and the corresponding code for prediction of plate fin-and-tube heat exchanger performance are developed. Dimensional Parameters Threaded tube (mm) (Aluminium) Straight Tube (mm) (Aluminium) Length of the heat exchanger 1000 1000 Inner diameter of the inner tube, di 16 16 Outer diameter of the inner tube, do 26 25 Inner diameter of the outer tube, Di 36 36 Outer diameter of the outer tube, Do 42 42 Pitch distance between threads 2.4 - Depth of threads 1.5 - II. METHODOLOGY AND EXPERIMENTATION Geometry is ascertained based on literature survey, pipe sizes available in market and heat duty. Manufacturing and fabrication of threaded tube. Insertion of simple instrumentation for thermal measurement. Study of variation of Reynolds number on the Nusselt number. Reduction of data to construct useful heat transfer correlations. A schematic diagram of the experimental apparatus is shown in Fig 1. The test loops consists of a test section, hot water loop, cold water loop and data measuring systems.
  • 3. Manufacturing and Comparative Analysis ... 79 Fig1. Schematic Diagram 1. Suction Pipe 2.Heaters 3. Cold Water Pipe 4. Hot Water Sensor 5. Cold Water Sensor 6. Cold Pipe Outlet 7. Threaded Heat Pipe. 8. M.S Outer Pipes 9. Non Threaded Heat Pipe 10. Delivery Pipe 11. FCV 12.Cold Pipe Inlet The test section is the water-to-water single-phase horizontal double pipe heat exchanger with two different configurations of the inner tube (threaded and non threaded). 2.1experimental Analysis A basic strategy to evaluate the heat exchanger’s performance is through the study of parameters like Nusselt Number, Reynolds number, etc and their impact on the overall heat transfer coefficient of the heat exchanger. In result table, LMTD, overall heat transfer coefficient, Nusselt numbers across the inner tube are calculated. The collected data is processed, analyzed and presented Reynolds number (1500 – 31000 range) and mass flow rates (0.055 to 0.220 kg/s) III. DESIGN OF DOUBLE PIPE HEAT EXCHANGER BY KERN METHOD FOR GIVEN SPECIFICATIONS Hot fluid inlet temperature, Thi= 65°C = 338K Cold fluid inlet temperature, Tci= 30°C = 303K Mass flow rate for hot fluid (water), qh = 200LPH Mass flow rate for cold fluid (water), qc = 200LPH For the process conditions specified above, design the double pipe heat exchanger of 2000W heat duty. Thermo-physical properties Hot fluid (water) at 65°C Cold fluid (water) at 30°C Density, ρ (kg/m3 ) 987.7 997.46 Thermal conductivity, k (W/m-K) 0.658 0.619 Specific heat, Cp (J/Kg-K) 4182 4182 Viscosity, μ (Pa-s) 0.422 x 10-3 0.777 x 10-3 Prandtl number, Pr 2.6062 5.1078 Various heat transfer equations and empirical correlations are used to determine various parameters such as Reynolds number, Nusselt number, heat transfer coefficient etc. The readings and observations are taken prior to calculation of above mentioned parameters In present work, experimentation is done for single-phase water to water tube in tube heat exchanger with threaded and non threaded inner pipe. This analytical work is further studied in detail and presented.
  • 4. Manufacturing and Comparative Analysis ... 80 results And Discussions Effect of flow rate on Nusselt Number Fig 2.Variation of inner tube Nusselt Number with Threaded and Straight inner tube flow rate for cold 200 LPH Fig.3.Variation of inner tube Nusselt Number with Threaded and Straight inner tube flow rate for cold 300 LPH Fig.4.Variation of inner tube Nusselt Number with Threaded and Straight inner tube flow rate for cold 400 LPH
  • 5. Manufacturing and Comparative Analysis ... 81 Effect of Nusselt Number on inner tube side Reynolds Number for different configurations of the inner tube (threaded and Straight) Fig 5.Variation of inner tube Nusselt Number with Reynolds number for threaded and Straight tube for cold 200 LPH. Fig 6. Variation of inner tube Nusselt Number with Reynolds number for threaded and Straight tube for cold 300 LPH
  • 6. Manufacturing and Comparative Analysis ... 82 Fig 7. Variation of inner tube Nusselt Number with Reynolds number for threaded and Straight tube for cold 400 LPH Effect of Convection coefficient for different configurations of the inner tube (threaded and Straight) Fig.8 Variation of inner tube Convection coefficient with Threaded and Straight inner tube flow rate for cold 200 LPH
  • 7. Manufacturing and Comparative Analysis ... 83 Fig 9.Variation of inner tube Convection coefficient with Threaded and Straight innertube flow rate for cold 300 LPH F Fig.10.Variation of inner tube Convection coefficient with Threaded and Straight inner tube flow rate for cold 400 LPH Qavgfor different configurations of the inner tube (threaded and Straight) Fig 11.Variation of Qavg with Threaded and Straight inner tube flow rate for cold 200 LPH
  • 8. Manufacturing and Comparative Analysis ... 84 Fig 12.Variation of Qavg with Threaded and Straight inner tube flow rate for cold 300 LPH Fig.13.Variation of Qavg with Threaded and Straight inner tube flow rate for cold 400 LPH 1. It is observed from the graph that the heat transfer rates of threaded pipe are more as compared to non- threaded pipe, keeping the cold flow rate (LPH) constant. 2. It is also observed from the graphs, that heat transfer rate for threaded pipe is more than non-threaded pipe for respective cold mass flow rate. 3. It is clear that the Nusselt Number of inner tube increases with increasing flow rate of water through inner tube. IV. CONCLUSIONS An experimental study has been performed to investigate the performance (pressure drop and Nu characteristic) for the two configurations of inner tube in the single phase water-to-water tube in tube heat exchanger (TTHE) i.e. threaded; non threaded. A two to four times more heat transfer enhancement is observed experimentally for the aforesaid heat exchanger with increased pumping power requirement of twice or thrice. Thus this work concludes that significant heat transfer enhancement is achieved for the threaded inner tube in TTHE. The work can be extended further for heavy heat duty industrial applications with wide operating conditions, different fluids and more precise instrumentation, provided that time and money are not constraints.
  • 9. Manufacturing and Comparative Analysis ... 85 REFERENCES [1] A.E. Bergles, “The imperative to enhance heat transfer”, Energy Conservation Through Heat Transfer Enhancement of Heat Exchangers, Turkey, 1998, pp. 547-563. [2] C.A. Balaras, “A review of augmentation techniques for heat transfer surfaces in single-phase heat exchangers”, Energy Conversion and Management, Vol. 15, 1990, pp. 899–906 [3] Wolverine INC “ Wolverine Tube heat transfer data book” [4] Yonghan Kim, Yongchan Kim “Heat transfer characteristics of flat plate finned-tube heat exchangers with large fin pitch”, Vol. 1 26 January 2005 [5] HT 307 “Finned tube heat exchanger” . [6] Creed Taylor “Measurement of finned-tube heat exchanger performance”. [7] Friedrich Frass “Principles of finned-tube heat exchanger design for enhanced heat transfer” [8] J.A.Livingstone“Effective Heat Transfer Enhancement in Finned Tube Heat Exchanger with different Fin Profiles” Vol.2, Issue 2 , 2013, pp:83-87 [9] Shiv Kumar Rathor “Comparative Analysis of Finned Tube and Bared Tube Type Shell and Tube Heat Exchanger” Vol. 2, Issue 1, July 2012 [10] Hamid Nabati “Optimal pin fin heat exchanger surface” 2008 [11] A. D.Kadam“ Perfomance simulation of fin and tube heat exchanger” IJESR Vol.2, Issue 10, 2012 [12] Sandeep R Desai “Determination of Modal parameters for finned tube heat exchanger tubes of various configurations” UJME 2013 [13] Kevin Lunsford “ Increasing heat exchanger performance” Bryan research and engineering, inc. 2006 [14] K P M Wipplinger “Stainless steel finned tube heat exchanger design for waste heat recovery” [15] M. V. Ghori “Numerical Analysis of Tube-fin Heat Exchanger using Fluent” [16] Jiin-YuhJang”Optimum louver angle design for a louvered fin heat exchanger” IJPS vol.6 pp 6422-6438 [17] AlaHasan “Performance investigation of plain and finned tube evaporatively cooled heat exchangers” [18] Chi-Chuan Wang “Recent advances in fin-and-tube heat exchanger” Vol.19, 2011, pp.291-301 [19] S. F Tsai “A comparison study on fin surfaces in finned-tube heat exchangers” IJNM Vol.9, 1999 pp.92-106 [20] W.K. Ding, J.F. Fan, Y.L. He, W.Q. Tao, Y.X. Zheng, Y.F. Gao, J. Song “A general simulation model for performance prediction of plate fin-and-tube heat exchanger with complex circuit configuration” Science Direct, 2011, pp.3106-3116. [21] R. K. Shah* and D. R Sekulib,University of Kentucky [22] PiotrWais,“Fin-Tube Heat Exchanger Optimization”PiotrWais,Cracow University of Technology, Department of Thermal Power Engineering, Poland [23] Kevin M. Lunsford, “Increasing Heat Exchanger Performance”Bryan Research & Engineering, Inc., Bryan, Texas [24] Comparative Analysis of Finned Tube and Bared Tube Type Shell and Tube Heat Exchanger Shiv Kumar Rathore, AjeetBergaley [25] M.R.Jafari Nasr and A. T. Zoghi “Full Analysis Of Low Finned Tube Heat Exchangers”,Research Institute of Petroleum Industry (RIPI), National Iranian Oil Company (NIOC)