OPEN SWITCH FAULT DIAGNOSIS IN THREE PHASE INVERTER
USING DIAGNOSTIC VARIABLE METHOD
Mala Ratan Ubale1
, R. B. Dhumale2
, S. D. Lokhande3
Department of Electronics and Telecommunication Engineering,
SCOE, Pune, Maharashtra, India
1
malaubale448@gmail.com, 2
rbd.scoe@gmail.com, 3
sdlokhande.scoe@sinhgad.edu
Abstract
The reliability of power electronics system such as three phase inverter is important in various applications. Different types of
faults occur in it, which may influence the operation of system. Such faults require unexpected maintenance, which increases the
cost of manufacturing. Therefore fault diagnosis of such devices plays vital role in industry. One possible fault that occurs in
inverter is an open switch fault. This paper provides a new technique based on diagnostic variable which detects single as well as
multiple open switch fault in three phase inverter. In this method, diagnostic variables are used to detect faulty phase. Along with
these diagnostic variables, an average current of three phase inverter is used for the detection of single as well as multiple faulty
switches.
Key Words: Power electronics, open switch fault, diagnostic variables.
--------------------------------------------------------------------***----------------------------------------------------------------------
1. INTRODUCTION
The voltage source inverter (VSI) is one of the most used
circuit configurations for speed control of three-phase
induction motors. The main objective of inverter is to
produce an ac output waveform from a dc power supply. A
fixed dc input voltage is given to the inverter and a
controlled ac output voltage is obtained by adjusting the on
and off periods of the inverter components. Three phase
inverter provides a three-phase voltage source, where the
amplitude, phase, and frequency of the voltages should
always be controllable. The Pulse Width Modulation
(PWM) is used to control the output voltage of inverter.
Three phase PWM inverter is used in many industrial
applications such as electric motor drives, UPS, active
power filters, etc. Different types of unexpected faults may
occurs in it. These AC drives systems are sensitive to
different types of fault occurring at the input rectifier, or at
the power inverter stage, or at the control sub system. In
general, when one of these faults occurs, system may
damage. The cost of these steps can be high. These inverter
faults may influence the operation of whole system. It is
necessary to avoid this harmful influence and to enhance the
reliability of the system. Therefore, fault detection and
diagnosis are needed.
It is estimated that among all types of faults in variable-
speed ac drives in industry, about 38% of the faults are due
to failures of power devices [1]. Most of these inverters use
insulated gate bipolar transistors (IGBTs) as the power
device because of their high voltage and current ratings and
ability to handle short-circuit currents for periods exceeding
10 μs. But they suffer failures due to excess electrical and
thermal stress that are experienced in many applications.
IGBT failures can be broadly classified as open-circuit
faults, short-circuit faults, and intermittent gate-misfiring
faults. There are several methods are available for detection
of inverter faults. In [2] and [3], the technique using Park’s
vector was proposed in which neural network is used for
diagnosis. But this technique requires very complex pattern
recognition algorithm. In [4] a fault detection using voltage
sensors was proposed. This method is fast but it requires
additional sensors. A method using a discrete Fourier
transform (DFT) was proposed in [5]. In this method Fourier
coefficients of current signal are used for fault diagnosis. In
[6] and [7], neural network is used. This neural network is
trained with the seven fault patterns which are calculated by
average current Concordia vector trajectory.
Most methods are used to find single switch fault and not
multiple switch faults. In this paper, open-circuit fault in
inverter is discussed. Presented method is able to detect
single as well as multiple open switch fault in three phase
inverter. The average absolute values of current are used to
calculate diagnostic variables. Some characteristics are
obtained with these diagnostic variables and average current
of inverter which are used to detect faulty phase and faulty
switches. This method is more robust to false alarm.
2. THREE PHASE INVERTER
An inverter is an electronic device which converts Direct
Current (DC) to Alternating Current (AC). This AC can be
of any required voltage and frequency. The Variable
Frequency Drive (VFD) mostly is of two types, Voltage
Source Inverter (VSI) and Current Source Inverter (CSI).
VSI has advantages like higher efficiencies, minimizing
installation timing, eliminating interconnect power cabling
costs, and reducing building floor space. Efficiencies are
IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308
_______________________________________________________________________________________
Volume: 02 Issue: 12 | Dec-2013, Available @ http://www.ijret.org 637
97% with high power factor through all load and speed
ranges. Fig. 1 shows basic structure of a three phase voltage
source inverter. In this model S1 to S6 are Insulated Gate
Bipolar Transistors (IGBTs) which can be on or off
Sinusoidal pulse width modulation (SPWM) is a common
technique for controlling the switches. The average value of
voltage fed to the load is controlled by turning the switch
between supply and load on and off at a high frequency.
Fig -1: Three Phase PWM Inverter
The simplest way to generate a PWM signal is the
intersective method, which requires a triangle waveform and
a comparator. When the value of the reference signal is
more than the modulation waveform, the PWM signal is in
the high state, otherwise it is in the low state.
In open circuit fault condition, the IGBT falls in the off state
and remains in this situation regardless of the gate voltage
value. Open-circuit fault occurs due to lifting of bonding
wires caused by thermic cycling. It may be caused by a
driver fault or a short-circuit-fault-induced IGBT rupture.
Open circuit faults generally do not cause system shutdown,
but degrade its performance. Therefore, these diagnostic
methods can be used in device-fault-tolerant systems.
3. FAULT DIAGNOSTIC METHOD:
3.1 Park’s vector approach:
The Park’s vector approach or dq transformation is
mathematical transformation which simplifies three phase
circuit. This method is used to transform three phase current
of voltage source inverter ( , , ) into two phase current
( , ). The Park’s vector components are given by [1],
=
2
3
−
1
√6
−
1
√6
(1)
i =
√
(i − i ) (2)
Using dq transformation the current patterns can be obtained
which indicates faulty situation of inverter current. It gives
different six patterns. A normal operation is represented by a
circle. If an open switch fault has occurred, there is a change
in the phase current value at the location of fault. Therefore,
a change in the circle shape represents the occurrence of an
open fault condition. When fault occurs, circle becomes
semicircle. Fig.2 shows dq transformation for normal and
faulty phase current of three phase inverter.
3.2 Normalization of currents:
The proposed method uses the dq transformation which
transforms three phase current into two phase. This method
requires only three phase currents as inputs and it does not
require any extra sensors.
(a) For normal operation
Fig -2: DQ transformation
Therefore, system complexity reduces. The normalization of
measured current is used to overcome the problem of
operating condition dependency and false diagnostics [8].
For normalization, dq transformation or Park’s vector
approach is used to calculate Park’s vector modulus, given
as
ǀ ǀ= + (3)
Where and are the Park’s vector components. The
normalization is done by dividing three phase current by
Park’s vector modulus. The normalized three phase current
is given by,
=
ǀ ǀ
(4)
Where n=a,b,c. Therefore, assuming that the motor is fed by
a healthy inverter generating a perfectly balanced three-
phase sinusoidal current system
=
"
#
$
= %& sin()*+ + ,)
= %& sin -)*+ −
.
/
+ ,0
= %& sin -)*+ +
.
/
+ ,0
1 (5)
where %& is the currents maximum amplitude, )* is the
motor currents frequency, and 3 is the initial phase angle.
Because of this normalization process, the normalized motor
phase currents will always take values within the range of
-5 -4 -3 -2 -1 0 1 2 3 4 5
-5
-4
-3
-2
-1
0
1
2
3
4
5
DQ Transformation
IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308
_______________________________________________________________________________________
Volume: 02 Issue: 12 | Dec-2013, Available @ http://www.ijret.org 638
±
/
, which is independent of the measured currents
amplitude,
=
"
55
#
55
$ =
/
sin ()*+ + ,)
=
/
sin ()*+ −
.
/
+ ,)
=
/
sin ()*+ +
.
/
+ ,)
1 (6)
3.3 Average absolute value of currents:
Average absolute values of three phase normalized currents
< ǀ ǀ > are given by,
)*
28
9 ǀ ǀ:+
;<
=
>
=
1
8
8
3
(7)
3.4 Diagnostic variables:
The three diagnostic variables A (where n=a,b,c) are
obtained from the errors of the normalized current’s average
absolute values, given by
A = B − 〈ǀ ǀ〉 (8)
Where B is a constant value equivalent to the average
absolute value of the normalized motor phase currents under
normal operating conditions given by (7), that is
B =
.
E
/
≈ 0.5198 (9)
The three diagnostic variables used for fault diagnosis
because they have specific characteristics [9]. For normal
operation, all the diagnostic variables will take values near
to zero. If an inverter open-circuit fault is introduced, at
least one of the diagnostic variables will takes positive
value. But these variables only give the information about
the faulty phase and not about faulty switches. Hence, along
with diagnostic variables, current’s average value is used to
detect faulty switches.
J =
"
#
$
K L A < 0
0 L 0 ≤ A < NO
P L NO ≤ A < N
Q L A ≥ N
1 (9)
S = T
U L 〈 〉 < 0
V L 〈 〉 > 0
1 (10)
The values of J and S are used to generate a distinct fault
signature. The threshold value NO is directly related to any
fault detection, while N performs an important role in case
of a double failure in the same inverter phase. Since the
method is normalized, it is not required to adjust these
values for each load and speed conditions. Table 1 gives
different diagnostic signatures. Here, value of NO and N are
considered as 0.00006 and 0.1996 respectively.
4. ARCHITECTURE OF FAULT DIAGNOSIS
First step of fault diagnosis of three phase PWM inverter is
to measure the three phase current and voltage. Measuring
of current and voltage is done with different conditions.
These measurements of current and signals are used for
further processing.
Table -1: Diagnostic signatures for faulty switch detection
Faulty
Switches
Ea Eb Ec Ma Mb Mc
S1 P N N L - -
S2 P N N H - -
S3 N P N - L -
S4 N P N - H -
S5 N N P - - L
S6 N N P - - H
S1,S2 D - - - - -
S3,S4 - D - - - -
S5,S6 - - D - - -
S1,S3 P P N L L H
S2,S4 P P N H H L
S3,S5 N P P H L L
S4,S6 N P P L H H
S1,S5 P N P L H L
S2,S6 P N P H L H
Data acquisition board is used to collect these signals and
transfer them from analog to digital signals. Because signal
processing can be done in digital domain. These signals then
import in MATLAB. The diagnostic variable method can be
applied on these signals to find whether inverter signals are
faulty or not. If so, then it will calculate location of faulty
switch. Fig. 3 shows fault diagnostic system for real time
application.
Fig -3: Fault detection system for real time application.
In this model, three phase inverter uses sinusoidal pulse
width modulation technique. Input for inverter is 1 ph 40 V,
50 Hz. Output voltage of inverter is 0 to 25 AC. Load is
IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308
_______________________________________________________________________________________
Volume: 02 Issue: 12 | Dec-2013, Available @ http://www.ijret.org 639
resistive in star or delta. Output frequency is 0 to 50 Hz.
Speed is controlled by frequency control. Data acquisition
is the process of sampling signal that measure real world
physical conditions and converting samples into digital
numeric values that can be manipulated by a computer. It
converts analog waveforms into digital values for
processing. It includes sensors to convert physical parameter
to electrical signal and signal conditioning circuitry to
convert sensor signals into a form that can be converted to a
digital form.
5. SIMULATION RESULTS
For simulation results, inverter should be simulated in
MATLAB for every fault mode. In this paper three distinct
faulty operations are considered, a single IGBT open-circuit
fault, a single-phase open-circuit fault (double fault in the
same inverter leg), and a double switch open-circuit fault.
Open switch fault can be introduced by removing respective
gate signal of switches.
a) Single IGBT open switch fault
Fig. 4 shows the time-domain waveforms of the three phase
inverter currents, the diagnostic variables and the
normalized current’s average values. An IGBT open-circuit
fault in switch S1 is introduced by removing its gate signal.
When the fault in IGBT S1 occurs, the diagnostic variable of
the corresponding phase A immediately increases,
converging to a value of 0.23. The other two remaining
errors will decrease until they reach a value of
approximately −0.08. S1 is upper switch of phase a,
therefore the current flows through bottom IGBT switch
which is large negative average value of current.
b) Single phase open circuit fault
Fig. 5 shows simulation results for single phase open circuit
fault in IGBT S1 and S2. In this case, the fault is introduced
in S1 and S2 by removing corresponding gate signals. As a
result, the diagnostic variable A will immediately increase
to a final value of 0.51. Remaining two diagnostic variables
will decreases, converging both to a value of about −0.18.
c) Double power switches open circuit fault
When the faults in transistors S1 and S3 are introduced, both
the diagnostic variables eX and e will increase and reach
values higher than kZ. The diagnostic variable of the normal
phase will decreases to negative value.
(a)
(b)
(c)
Fig -4: Simulation results of (a) inverter three phase
current,(b) diagnostic variables and (c) normalized currents
average values when open switch fault in switch S1.
(a)
(b)
(c)
Fig -5: Simulation results of (a) inverter three phase
current,(b) diagnostic variables and (c) normalized currents
average values when open switch fault introduced in switch
S1 and S2.
CONCLUSION
In this paper, a new diagnosis scheme for three phase
inverter IGBT open switch faults is presented. In proposed
method, three phase current of inverter is used as input to
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000
-5
-4
-3
-2
-1
0
1
2
3
4
Three phase current of inverter
Ia
Ib
Ic
0 1000 2000 3000 4000 5000 6000 7000 8000
-0.3
-0.2
-0.1
0
0.1
0.2
0.3
0.4
Diagnostic Variables
ea
eb
ec
0 1000 2000 3000 4000 5000 6000 7000 8000
-0.8
-0.6
-0.4
-0.2
0
0.2
0.4
0.6
0.8
1
Normalized current average values
<IaN>
<IbN>
<IcN>
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000
-4
-3
-2
-1
0
1
2
3
4
Three phase current of inverter
Ia
Ib
Ic
0 2000 4000 6000 8000
-0.2
-0.1
0
0.1
0.2
0.3
0.4
0.5
0.6
Diagnostic Variables
ea
eb
ec
0 1000 2000 3000 4000 5000 6000 7000 8000
-0.8
-0.6
-0.4
-0.2
0
0.2
0.4
0.6
0.8
Normalized current average values
<IaN>
<IbN>
<IcN>
IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308
_______________________________________________________________________________________
Volume: 02 Issue: 12 | Dec-2013, Available @ http://www.ijret.org 640
diagnostic method. This method avoids extra sensors and
therefore reduces cost of manufacturing. The diagnostic
variables provide the information about faulty phase. Along
with this, average normalized three phase current, faulty
switches can be detected. This method gives detection of
single as well as multiple faulty switches. Because of
normalization method, this method becomes independent on
load level or motor speed.
REFERENCES
[1] F. W. Fuchs, “Some diagnosis methods for voltage
source inverters in variable speed drives with induction
machines—A survey,” in Proc. IEEE Ind. Electron.
Conf., 2003, pp. 1378–1385.
[2] K. Rothenhagen and F. W. Fuchs, “Performance of
diagnosis methods for IGBT open circuit faults in
voltage source active rectifiers,” IEEE PESC proc.,
2004, pp.4348-4354.
[3] A. M. S. Mendes, A. J. M. Cardoso, and E. S. Saraiva,
“Voltage source inverter fault diagnosis in variable
speed AC drives, by the average current Park's vector
approach,” IEEE IEMDC Proc., 1999, pp.704-706.
[4] R. L. A. Ribeiro, C. B. Jacobina, E. R. C. Silva, and A.
M. N. Lima, “Fault detection of open-switch damage in
voltage-fed PWM motor drive systems,” IEEE Trans.
Power Electron., vol. 18, no. 2, pp. 587–593, Mar.
2003.
[5] C. Kral and K. Kafka, “Power electronics monitoring
for a controlled voltage source inverter drive with
induction machines,” in Proc. IEEE 31st Annu. Power
Electron. Spec. Conf., 2000, vol. 1, pp. 213–217.
[6] D. Diallo, M. E. H. Benbouzid, D. Hamad, and X.
Pierre, “Fault detection and diagnosis in an induction
machine drive: a pattern recognition approach based on
concordia stator mean current vector,” IEEE Trans.
Energy Conv., vol. 20, no. 3, pp. 512-519, Sept. 2005.
[7] J. H. Park, D. H. Kim, S. S. Kim, D. J. Lee, and M. G.
Chun, “C-ANFIS based fault diagnosis for voltage-fed
PWM motor drive systems,” IEEENAFIPS proc., 2004,
pp.379-383
[8] J. O. Estima and A. J. M. Cardoso, “A novel diagnostic
method for single power switch open-circuit faults in
voltage-fed PWM motor drives,” in Proc. Int. Symp.
Power Electron., Elect. Drives, Autom. Motion, Pisa,
Italy, Jun. 14–16, 2010, pp. 535–540.
[9] Jorge O. Estima and Antonio J. Marques Cardoso, “A
New Approach for Real-Time Multiple Open-Circuit
Fault Diagnosis in Voltage-Source Inverters”, IEEE
Transactions on Industry Applications, Vol. 47, No. 6,
Nov/Dec 2011.
IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 |
pISSN: 2321-7308
___________________________________________________________________________
____________
Volume: 02 Issue: 12 | Dec-2013, Available @ http://www.ijret.org 641

Weitere ähnliche Inhalte

Was ist angesagt?

Dynamic model of zeta converter with full state
Dynamic model of zeta converter with full stateDynamic model of zeta converter with full state
Dynamic model of zeta converter with full state
eSAT Publishing House
 
Next Generation Researchers in Power Systems_Tao Yang_UCD EI
Next Generation Researchers in Power Systems_Tao Yang_UCD EINext Generation Researchers in Power Systems_Tao Yang_UCD EI
Next Generation Researchers in Power Systems_Tao Yang_UCD EI
Tao Yang
 

Was ist angesagt? (19)

Analysis and mitigation of unbalance due to load in distribution system by us...
Analysis and mitigation of unbalance due to load in distribution system by us...Analysis and mitigation of unbalance due to load in distribution system by us...
Analysis and mitigation of unbalance due to load in distribution system by us...
 
Analysis and mitigation of unbalance due to load in
Analysis and mitigation of unbalance due to load inAnalysis and mitigation of unbalance due to load in
Analysis and mitigation of unbalance due to load in
 
Power System State Estimation - A Review
Power System State Estimation - A ReviewPower System State Estimation - A Review
Power System State Estimation - A Review
 
Detection of Broken Bars in Three Phase Squirrel Cage Induction Motor using F...
Detection of Broken Bars in Three Phase Squirrel Cage Induction Motor using F...Detection of Broken Bars in Three Phase Squirrel Cage Induction Motor using F...
Detection of Broken Bars in Three Phase Squirrel Cage Induction Motor using F...
 
Current mode controlled fuzzy logic based inter leaved cuk converter SVM inve...
Current mode controlled fuzzy logic based inter leaved cuk converter SVM inve...Current mode controlled fuzzy logic based inter leaved cuk converter SVM inve...
Current mode controlled fuzzy logic based inter leaved cuk converter SVM inve...
 
M356872
M356872M356872
M356872
 
Detection and analysis of eccentricity
Detection and analysis of eccentricityDetection and analysis of eccentricity
Detection and analysis of eccentricity
 
Dynamic model of zeta converter with full state
Dynamic model of zeta converter with full stateDynamic model of zeta converter with full state
Dynamic model of zeta converter with full state
 
Advanced Direct Power Control for Grid-connected Distribution Generation Syst...
Advanced Direct Power Control for Grid-connected Distribution Generation Syst...Advanced Direct Power Control for Grid-connected Distribution Generation Syst...
Advanced Direct Power Control for Grid-connected Distribution Generation Syst...
 
Next Generation Researchers in Power Systems_Tao Yang_UCD EI
Next Generation Researchers in Power Systems_Tao Yang_UCD EINext Generation Researchers in Power Systems_Tao Yang_UCD EI
Next Generation Researchers in Power Systems_Tao Yang_UCD EI
 
Dynamic model of zeta converter with full state feedback controller implement...
Dynamic model of zeta converter with full state feedback controller implement...Dynamic model of zeta converter with full state feedback controller implement...
Dynamic model of zeta converter with full state feedback controller implement...
 
A real-time fault diagnosis system for high-speed power system protection bas...
A real-time fault diagnosis system for high-speed power system protection bas...A real-time fault diagnosis system for high-speed power system protection bas...
A real-time fault diagnosis system for high-speed power system protection bas...
 
Current Controller Based Power Management Strategy for Interfacing DG Units t...
Current Controller Based Power Management Strategy for Interfacing DG Units t...Current Controller Based Power Management Strategy for Interfacing DG Units t...
Current Controller Based Power Management Strategy for Interfacing DG Units t...
 
Two parallel single phase rectifiers by using single phase to three phase ind...
Two parallel single phase rectifiers by using single phase to three phase ind...Two parallel single phase rectifiers by using single phase to three phase ind...
Two parallel single phase rectifiers by using single phase to three phase ind...
 
Two parallel single phase rectifiers by using single
Two parallel single phase rectifiers by using singleTwo parallel single phase rectifiers by using single
Two parallel single phase rectifiers by using single
 
interconnected powersystem
interconnected powersysteminterconnected powersystem
interconnected powersystem
 
Power quality improvement of grid interconnected distribution system using fs...
Power quality improvement of grid interconnected distribution system using fs...Power quality improvement of grid interconnected distribution system using fs...
Power quality improvement of grid interconnected distribution system using fs...
 
Embedded based sensorless control of pmbldc motor with voltage controlled pfc...
Embedded based sensorless control of pmbldc motor with voltage controlled pfc...Embedded based sensorless control of pmbldc motor with voltage controlled pfc...
Embedded based sensorless control of pmbldc motor with voltage controlled pfc...
 
TRANSIENT STABILITY ENHANCEMENT BY USING DSSC AND PSS
TRANSIENT STABILITY ENHANCEMENT BY USING DSSC AND PSSTRANSIENT STABILITY ENHANCEMENT BY USING DSSC AND PSS
TRANSIENT STABILITY ENHANCEMENT BY USING DSSC AND PSS
 

Andere mochten auch

Intelligent two axis dual-ccd image-servo shooting platform design
Intelligent two axis dual-ccd image-servo shooting platform designIntelligent two axis dual-ccd image-servo shooting platform design
Intelligent two axis dual-ccd image-servo shooting platform design
eSAT Publishing House
 
Behavior of self compacting concrete using ppc and opc with different proport...
Behavior of self compacting concrete using ppc and opc with different proport...Behavior of self compacting concrete using ppc and opc with different proport...
Behavior of self compacting concrete using ppc and opc with different proport...
eSAT Publishing House
 

Andere mochten auch (20)

An optimized approach to voice translation on mobile phones
An optimized approach to voice translation on mobile phonesAn optimized approach to voice translation on mobile phones
An optimized approach to voice translation on mobile phones
 
Chemread – a chemical informant
Chemread – a chemical informantChemread – a chemical informant
Chemread – a chemical informant
 
Intelligent two axis dual-ccd image-servo shooting platform design
Intelligent two axis dual-ccd image-servo shooting platform designIntelligent two axis dual-ccd image-servo shooting platform design
Intelligent two axis dual-ccd image-servo shooting platform design
 
Behavior of self compacting concrete using ppc and opc with different proport...
Behavior of self compacting concrete using ppc and opc with different proport...Behavior of self compacting concrete using ppc and opc with different proport...
Behavior of self compacting concrete using ppc and opc with different proport...
 
An extended database reverse engineering – a key for database forensic invest...
An extended database reverse engineering – a key for database forensic invest...An extended database reverse engineering – a key for database forensic invest...
An extended database reverse engineering – a key for database forensic invest...
 
Overall increase in efficiency in raw meals
Overall increase in efficiency in raw mealsOverall increase in efficiency in raw meals
Overall increase in efficiency in raw meals
 
Comparison of data security in grid and cloud
Comparison of data security in grid and cloudComparison of data security in grid and cloud
Comparison of data security in grid and cloud
 
Biodiesel as a blended fuel in compression ignition
Biodiesel as a blended fuel in compression ignitionBiodiesel as a blended fuel in compression ignition
Biodiesel as a blended fuel in compression ignition
 
Evaluation of green act in small scale foundry
Evaluation of green act in small scale foundryEvaluation of green act in small scale foundry
Evaluation of green act in small scale foundry
 
Zigbee sensor network integrated with 4 g for iot
Zigbee sensor network integrated with 4 g for iotZigbee sensor network integrated with 4 g for iot
Zigbee sensor network integrated with 4 g for iot
 
Energy saving model and application for smart phones
Energy saving model and application for smart phonesEnergy saving model and application for smart phones
Energy saving model and application for smart phones
 
Secure intrusion detection and countermeasure selection in virtual system usi...
Secure intrusion detection and countermeasure selection in virtual system usi...Secure intrusion detection and countermeasure selection in virtual system usi...
Secure intrusion detection and countermeasure selection in virtual system usi...
 
Surveillance and tracking of elephants using vocal spectral information
Surveillance and tracking of elephants using vocal spectral informationSurveillance and tracking of elephants using vocal spectral information
Surveillance and tracking of elephants using vocal spectral information
 
Development of mobile surface water filtration system through simulation usin...
Development of mobile surface water filtration system through simulation usin...Development of mobile surface water filtration system through simulation usin...
Development of mobile surface water filtration system through simulation usin...
 
Building extraction from remote sensing imageries by data fusion techniques
Building extraction from remote sensing imageries by data fusion techniquesBuilding extraction from remote sensing imageries by data fusion techniques
Building extraction from remote sensing imageries by data fusion techniques
 
Applications of layered theory for the analysis of flexible pavements
Applications of layered theory for the analysis of flexible pavementsApplications of layered theory for the analysis of flexible pavements
Applications of layered theory for the analysis of flexible pavements
 
Economics of a high performance solar distilled water
Economics of a high performance solar distilled waterEconomics of a high performance solar distilled water
Economics of a high performance solar distilled water
 
Secure and efficient transmission of medical images
Secure and efficient transmission of medical imagesSecure and efficient transmission of medical images
Secure and efficient transmission of medical images
 
Multi criteria decision model for biodiesel selection in an electrical powe...
Multi   criteria decision model for biodiesel selection in an electrical powe...Multi   criteria decision model for biodiesel selection in an electrical powe...
Multi criteria decision model for biodiesel selection in an electrical powe...
 
An enhancing security for mobile sinks by providing location privacy in wsn
An enhancing security for mobile sinks by providing location privacy in wsnAn enhancing security for mobile sinks by providing location privacy in wsn
An enhancing security for mobile sinks by providing location privacy in wsn
 

Ähnlich wie Open switch fault diagnosis in three phase inverter

Power grid synchronization failure detection and recovery
Power grid synchronization failure detection and recoveryPower grid synchronization failure detection and recovery
Power grid synchronization failure detection and recovery
eSAT Journals
 
Dsp based implementation of field oriented control of
Dsp based implementation of field oriented control ofDsp based implementation of field oriented control of
Dsp based implementation of field oriented control of
eSAT Publishing House
 
Design and development of grid tie inverter with closed loop spwm single stag...
Design and development of grid tie inverter with closed loop spwm single stag...Design and development of grid tie inverter with closed loop spwm single stag...
Design and development of grid tie inverter with closed loop spwm single stag...
eSAT Journals
 

Ähnlich wie Open switch fault diagnosis in three phase inverter (20)

B010620715
B010620715B010620715
B010620715
 
Power grid synchronization failure detection and recovery
Power grid synchronization failure detection and recoveryPower grid synchronization failure detection and recovery
Power grid synchronization failure detection and recovery
 
Dsp based implementation of field oriented control of three phase induction m...
Dsp based implementation of field oriented control of three phase induction m...Dsp based implementation of field oriented control of three phase induction m...
Dsp based implementation of field oriented control of three phase induction m...
 
An enhanced mppt technique for small scale
An enhanced mppt technique for small scaleAn enhanced mppt technique for small scale
An enhanced mppt technique for small scale
 
Dsp based implementation of field oriented control of
Dsp based implementation of field oriented control ofDsp based implementation of field oriented control of
Dsp based implementation of field oriented control of
 
Dsp based implementation of field oriented control of
Dsp based implementation of field oriented control ofDsp based implementation of field oriented control of
Dsp based implementation of field oriented control of
 
PWM-Switching pattern-based diagnosis scheme for single and multiple open-swi...
PWM-Switching pattern-based diagnosis scheme for single and multiple open-swi...PWM-Switching pattern-based diagnosis scheme for single and multiple open-swi...
PWM-Switching pattern-based diagnosis scheme for single and multiple open-swi...
 
Open-Switch Fault-Tolerant Control of a Grid-Side Converter in a Wind Power G...
Open-Switch Fault-Tolerant Control of a Grid-Side Converter in a Wind Power G...Open-Switch Fault-Tolerant Control of a Grid-Side Converter in a Wind Power G...
Open-Switch Fault-Tolerant Control of a Grid-Side Converter in a Wind Power G...
 
Integrated grid inverter with frequency control scheme for wind mill applicat...
Integrated grid inverter with frequency control scheme for wind mill applicat...Integrated grid inverter with frequency control scheme for wind mill applicat...
Integrated grid inverter with frequency control scheme for wind mill applicat...
 
Emc model for modern power electronic systems for
Emc model for modern power electronic systems forEmc model for modern power electronic systems for
Emc model for modern power electronic systems for
 
Emc model for modern power electronic systems for harmonics, losses &amp; emi...
Emc model for modern power electronic systems for harmonics, losses &amp; emi...Emc model for modern power electronic systems for harmonics, losses &amp; emi...
Emc model for modern power electronic systems for harmonics, losses &amp; emi...
 
38
3838
38
 
MRA Analysis for Faults Indentification in Multilevel Inverter
MRA Analysis for Faults Indentification in Multilevel InverterMRA Analysis for Faults Indentification in Multilevel Inverter
MRA Analysis for Faults Indentification in Multilevel Inverter
 
A Fault Detection and Classification Method for SC Transmission Line Using Ph...
A Fault Detection and Classification Method for SC Transmission Line Using Ph...A Fault Detection and Classification Method for SC Transmission Line Using Ph...
A Fault Detection and Classification Method for SC Transmission Line Using Ph...
 
OPTIMAL TORQUE RIPPLE CONTROL OF ASYNCHRONOUS DRIVE USING INTELLIGENT CONTROL...
OPTIMAL TORQUE RIPPLE CONTROL OF ASYNCHRONOUS DRIVE USING INTELLIGENT CONTROL...OPTIMAL TORQUE RIPPLE CONTROL OF ASYNCHRONOUS DRIVE USING INTELLIGENT CONTROL...
OPTIMAL TORQUE RIPPLE CONTROL OF ASYNCHRONOUS DRIVE USING INTELLIGENT CONTROL...
 
IRJET- Condition Monitoring and Faulty Insulator Locating using Park’s Transf...
IRJET- Condition Monitoring and Faulty Insulator Locating using Park’s Transf...IRJET- Condition Monitoring and Faulty Insulator Locating using Park’s Transf...
IRJET- Condition Monitoring and Faulty Insulator Locating using Park’s Transf...
 
Automation and Calibration for Discrete Transducer: A Survey
Automation and Calibration for Discrete Transducer: A SurveyAutomation and Calibration for Discrete Transducer: A Survey
Automation and Calibration for Discrete Transducer: A Survey
 
Design and development of grid tie inverter with closed loop spwm single stag...
Design and development of grid tie inverter with closed loop spwm single stag...Design and development of grid tie inverter with closed loop spwm single stag...
Design and development of grid tie inverter with closed loop spwm single stag...
 
Duty Cycle Corrector Using Pulse Width Modulation
Duty Cycle Corrector Using Pulse Width ModulationDuty Cycle Corrector Using Pulse Width Modulation
Duty Cycle Corrector Using Pulse Width Modulation
 
International Journal of VLSI design & Communication Systems (VLSICS)
International Journal of VLSI design & Communication Systems (VLSICS) International Journal of VLSI design & Communication Systems (VLSICS)
International Journal of VLSI design & Communication Systems (VLSICS)
 

Mehr von eSAT Publishing House

Likely impacts of hudhud on the environment of visakhapatnam
Likely impacts of hudhud on the environment of visakhapatnamLikely impacts of hudhud on the environment of visakhapatnam
Likely impacts of hudhud on the environment of visakhapatnam
eSAT Publishing House
 
Impact of flood disaster in a drought prone area – case study of alampur vill...
Impact of flood disaster in a drought prone area – case study of alampur vill...Impact of flood disaster in a drought prone area – case study of alampur vill...
Impact of flood disaster in a drought prone area – case study of alampur vill...
eSAT Publishing House
 
Hudhud cyclone – a severe disaster in visakhapatnam
Hudhud cyclone – a severe disaster in visakhapatnamHudhud cyclone – a severe disaster in visakhapatnam
Hudhud cyclone – a severe disaster in visakhapatnam
eSAT Publishing House
 
Groundwater investigation using geophysical methods a case study of pydibhim...
Groundwater investigation using geophysical methods  a case study of pydibhim...Groundwater investigation using geophysical methods  a case study of pydibhim...
Groundwater investigation using geophysical methods a case study of pydibhim...
eSAT Publishing House
 
Flood related disasters concerned to urban flooding in bangalore, india
Flood related disasters concerned to urban flooding in bangalore, indiaFlood related disasters concerned to urban flooding in bangalore, india
Flood related disasters concerned to urban flooding in bangalore, india
eSAT Publishing House
 
Enhancing post disaster recovery by optimal infrastructure capacity building
Enhancing post disaster recovery by optimal infrastructure capacity buildingEnhancing post disaster recovery by optimal infrastructure capacity building
Enhancing post disaster recovery by optimal infrastructure capacity building
eSAT Publishing House
 
Effect of lintel and lintel band on the global performance of reinforced conc...
Effect of lintel and lintel band on the global performance of reinforced conc...Effect of lintel and lintel band on the global performance of reinforced conc...
Effect of lintel and lintel band on the global performance of reinforced conc...
eSAT Publishing House
 
Wind damage to trees in the gitam university campus at visakhapatnam by cyclo...
Wind damage to trees in the gitam university campus at visakhapatnam by cyclo...Wind damage to trees in the gitam university campus at visakhapatnam by cyclo...
Wind damage to trees in the gitam university campus at visakhapatnam by cyclo...
eSAT Publishing House
 
Wind damage to buildings, infrastrucuture and landscape elements along the be...
Wind damage to buildings, infrastrucuture and landscape elements along the be...Wind damage to buildings, infrastrucuture and landscape elements along the be...
Wind damage to buildings, infrastrucuture and landscape elements along the be...
eSAT Publishing House
 
Shear strength of rc deep beam panels – a review
Shear strength of rc deep beam panels – a reviewShear strength of rc deep beam panels – a review
Shear strength of rc deep beam panels – a review
eSAT Publishing House
 
Role of voluntary teams of professional engineers in dissater management – ex...
Role of voluntary teams of professional engineers in dissater management – ex...Role of voluntary teams of professional engineers in dissater management – ex...
Role of voluntary teams of professional engineers in dissater management – ex...
eSAT Publishing House
 
Risk analysis and environmental hazard management
Risk analysis and environmental hazard managementRisk analysis and environmental hazard management
Risk analysis and environmental hazard management
eSAT Publishing House
 
Review study on performance of seismically tested repaired shear walls
Review study on performance of seismically tested repaired shear wallsReview study on performance of seismically tested repaired shear walls
Review study on performance of seismically tested repaired shear walls
eSAT Publishing House
 
Monitoring and assessment of air quality with reference to dust particles (pm...
Monitoring and assessment of air quality with reference to dust particles (pm...Monitoring and assessment of air quality with reference to dust particles (pm...
Monitoring and assessment of air quality with reference to dust particles (pm...
eSAT Publishing House
 
Low cost wireless sensor networks and smartphone applications for disaster ma...
Low cost wireless sensor networks and smartphone applications for disaster ma...Low cost wireless sensor networks and smartphone applications for disaster ma...
Low cost wireless sensor networks and smartphone applications for disaster ma...
eSAT Publishing House
 
Coastal zones – seismic vulnerability an analysis from east coast of india
Coastal zones – seismic vulnerability an analysis from east coast of indiaCoastal zones – seismic vulnerability an analysis from east coast of india
Coastal zones – seismic vulnerability an analysis from east coast of india
eSAT Publishing House
 
Can fracture mechanics predict damage due disaster of structures
Can fracture mechanics predict damage due disaster of structuresCan fracture mechanics predict damage due disaster of structures
Can fracture mechanics predict damage due disaster of structures
eSAT Publishing House
 
Assessment of seismic susceptibility of rc buildings
Assessment of seismic susceptibility of rc buildingsAssessment of seismic susceptibility of rc buildings
Assessment of seismic susceptibility of rc buildings
eSAT Publishing House
 
A geophysical insight of earthquake occurred on 21 st may 2014 off paradip, b...
A geophysical insight of earthquake occurred on 21 st may 2014 off paradip, b...A geophysical insight of earthquake occurred on 21 st may 2014 off paradip, b...
A geophysical insight of earthquake occurred on 21 st may 2014 off paradip, b...
eSAT Publishing House
 
Effect of hudhud cyclone on the development of visakhapatnam as smart and gre...
Effect of hudhud cyclone on the development of visakhapatnam as smart and gre...Effect of hudhud cyclone on the development of visakhapatnam as smart and gre...
Effect of hudhud cyclone on the development of visakhapatnam as smart and gre...
eSAT Publishing House
 

Mehr von eSAT Publishing House (20)

Likely impacts of hudhud on the environment of visakhapatnam
Likely impacts of hudhud on the environment of visakhapatnamLikely impacts of hudhud on the environment of visakhapatnam
Likely impacts of hudhud on the environment of visakhapatnam
 
Impact of flood disaster in a drought prone area – case study of alampur vill...
Impact of flood disaster in a drought prone area – case study of alampur vill...Impact of flood disaster in a drought prone area – case study of alampur vill...
Impact of flood disaster in a drought prone area – case study of alampur vill...
 
Hudhud cyclone – a severe disaster in visakhapatnam
Hudhud cyclone – a severe disaster in visakhapatnamHudhud cyclone – a severe disaster in visakhapatnam
Hudhud cyclone – a severe disaster in visakhapatnam
 
Groundwater investigation using geophysical methods a case study of pydibhim...
Groundwater investigation using geophysical methods  a case study of pydibhim...Groundwater investigation using geophysical methods  a case study of pydibhim...
Groundwater investigation using geophysical methods a case study of pydibhim...
 
Flood related disasters concerned to urban flooding in bangalore, india
Flood related disasters concerned to urban flooding in bangalore, indiaFlood related disasters concerned to urban flooding in bangalore, india
Flood related disasters concerned to urban flooding in bangalore, india
 
Enhancing post disaster recovery by optimal infrastructure capacity building
Enhancing post disaster recovery by optimal infrastructure capacity buildingEnhancing post disaster recovery by optimal infrastructure capacity building
Enhancing post disaster recovery by optimal infrastructure capacity building
 
Effect of lintel and lintel band on the global performance of reinforced conc...
Effect of lintel and lintel band on the global performance of reinforced conc...Effect of lintel and lintel band on the global performance of reinforced conc...
Effect of lintel and lintel band on the global performance of reinforced conc...
 
Wind damage to trees in the gitam university campus at visakhapatnam by cyclo...
Wind damage to trees in the gitam university campus at visakhapatnam by cyclo...Wind damage to trees in the gitam university campus at visakhapatnam by cyclo...
Wind damage to trees in the gitam university campus at visakhapatnam by cyclo...
 
Wind damage to buildings, infrastrucuture and landscape elements along the be...
Wind damage to buildings, infrastrucuture and landscape elements along the be...Wind damage to buildings, infrastrucuture and landscape elements along the be...
Wind damage to buildings, infrastrucuture and landscape elements along the be...
 
Shear strength of rc deep beam panels – a review
Shear strength of rc deep beam panels – a reviewShear strength of rc deep beam panels – a review
Shear strength of rc deep beam panels – a review
 
Role of voluntary teams of professional engineers in dissater management – ex...
Role of voluntary teams of professional engineers in dissater management – ex...Role of voluntary teams of professional engineers in dissater management – ex...
Role of voluntary teams of professional engineers in dissater management – ex...
 
Risk analysis and environmental hazard management
Risk analysis and environmental hazard managementRisk analysis and environmental hazard management
Risk analysis and environmental hazard management
 
Review study on performance of seismically tested repaired shear walls
Review study on performance of seismically tested repaired shear wallsReview study on performance of seismically tested repaired shear walls
Review study on performance of seismically tested repaired shear walls
 
Monitoring and assessment of air quality with reference to dust particles (pm...
Monitoring and assessment of air quality with reference to dust particles (pm...Monitoring and assessment of air quality with reference to dust particles (pm...
Monitoring and assessment of air quality with reference to dust particles (pm...
 
Low cost wireless sensor networks and smartphone applications for disaster ma...
Low cost wireless sensor networks and smartphone applications for disaster ma...Low cost wireless sensor networks and smartphone applications for disaster ma...
Low cost wireless sensor networks and smartphone applications for disaster ma...
 
Coastal zones – seismic vulnerability an analysis from east coast of india
Coastal zones – seismic vulnerability an analysis from east coast of indiaCoastal zones – seismic vulnerability an analysis from east coast of india
Coastal zones – seismic vulnerability an analysis from east coast of india
 
Can fracture mechanics predict damage due disaster of structures
Can fracture mechanics predict damage due disaster of structuresCan fracture mechanics predict damage due disaster of structures
Can fracture mechanics predict damage due disaster of structures
 
Assessment of seismic susceptibility of rc buildings
Assessment of seismic susceptibility of rc buildingsAssessment of seismic susceptibility of rc buildings
Assessment of seismic susceptibility of rc buildings
 
A geophysical insight of earthquake occurred on 21 st may 2014 off paradip, b...
A geophysical insight of earthquake occurred on 21 st may 2014 off paradip, b...A geophysical insight of earthquake occurred on 21 st may 2014 off paradip, b...
A geophysical insight of earthquake occurred on 21 st may 2014 off paradip, b...
 
Effect of hudhud cyclone on the development of visakhapatnam as smart and gre...
Effect of hudhud cyclone on the development of visakhapatnam as smart and gre...Effect of hudhud cyclone on the development of visakhapatnam as smart and gre...
Effect of hudhud cyclone on the development of visakhapatnam as smart and gre...
 

Kürzlich hochgeladen

AKTU Computer Networks notes --- Unit 3.pdf
AKTU Computer Networks notes ---  Unit 3.pdfAKTU Computer Networks notes ---  Unit 3.pdf
AKTU Computer Networks notes --- Unit 3.pdf
ankushspencer015
 
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak HamilCara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Kandungan 087776558899
 
Call Girls in Netaji Nagar, Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
Call Girls in Netaji Nagar, Delhi 💯 Call Us 🔝9953056974 🔝 Escort ServiceCall Girls in Netaji Nagar, Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
Call Girls in Netaji Nagar, Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
9953056974 Low Rate Call Girls In Saket, Delhi NCR
 
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night StandCall Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
amitlee9823
 
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar ≼🔝 Delhi door step de...
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar  ≼🔝 Delhi door step de...Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar  ≼🔝 Delhi door step de...
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar ≼🔝 Delhi door step de...
9953056974 Low Rate Call Girls In Saket, Delhi NCR
 

Kürzlich hochgeladen (20)

FEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced Loads
FEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced LoadsFEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced Loads
FEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced Loads
 
AKTU Computer Networks notes --- Unit 3.pdf
AKTU Computer Networks notes ---  Unit 3.pdfAKTU Computer Networks notes ---  Unit 3.pdf
AKTU Computer Networks notes --- Unit 3.pdf
 
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete RecordCCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
 
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak HamilCara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
 
Design For Accessibility: Getting it right from the start
Design For Accessibility: Getting it right from the startDesign For Accessibility: Getting it right from the start
Design For Accessibility: Getting it right from the start
 
Thermal Engineering Unit - I & II . ppt
Thermal Engineering  Unit - I & II . pptThermal Engineering  Unit - I & II . ppt
Thermal Engineering Unit - I & II . ppt
 
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
 
Bhosari ( Call Girls ) Pune 6297143586 Hot Model With Sexy Bhabi Ready For ...
Bhosari ( Call Girls ) Pune  6297143586  Hot Model With Sexy Bhabi Ready For ...Bhosari ( Call Girls ) Pune  6297143586  Hot Model With Sexy Bhabi Ready For ...
Bhosari ( Call Girls ) Pune 6297143586 Hot Model With Sexy Bhabi Ready For ...
 
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
 
Call Girls in Netaji Nagar, Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
Call Girls in Netaji Nagar, Delhi 💯 Call Us 🔝9953056974 🔝 Escort ServiceCall Girls in Netaji Nagar, Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
Call Girls in Netaji Nagar, Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
 
(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7
(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7
(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7
 
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night StandCall Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
 
Intro To Electric Vehicles PDF Notes.pdf
Intro To Electric Vehicles PDF Notes.pdfIntro To Electric Vehicles PDF Notes.pdf
Intro To Electric Vehicles PDF Notes.pdf
 
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar ≼🔝 Delhi door step de...
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar  ≼🔝 Delhi door step de...Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar  ≼🔝 Delhi door step de...
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar ≼🔝 Delhi door step de...
 
Unit 1 - Soil Classification and Compaction.pdf
Unit 1 - Soil Classification and Compaction.pdfUnit 1 - Soil Classification and Compaction.pdf
Unit 1 - Soil Classification and Compaction.pdf
 
Water Industry Process Automation & Control Monthly - April 2024
Water Industry Process Automation & Control Monthly - April 2024Water Industry Process Automation & Control Monthly - April 2024
Water Industry Process Automation & Control Monthly - April 2024
 
Thermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.pptThermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.ppt
 
Work-Permit-Receiver-in-Saudi-Aramco.pptx
Work-Permit-Receiver-in-Saudi-Aramco.pptxWork-Permit-Receiver-in-Saudi-Aramco.pptx
Work-Permit-Receiver-in-Saudi-Aramco.pptx
 
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance BookingCall Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Booking
 
Call Girls Wakad Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Wakad Call Me 7737669865 Budget Friendly No Advance BookingCall Girls Wakad Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Wakad Call Me 7737669865 Budget Friendly No Advance Booking
 

Open switch fault diagnosis in three phase inverter

  • 1. IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 _______________________________________________________________________________________ Volume: 02 Issue: 12 | Dec-2013, Available @ http://www.ijret.org 636 OPEN SWITCH FAULT DIAGNOSIS IN THREE PHASE INVERTER USING DIAGNOSTIC VARIABLE METHOD Mala Ratan Ubale1 , R. B. Dhumale2 , S. D. Lokhande3 Department of Electronics and Telecommunication Engineering, SCOE, Pune, Maharashtra, India 1 malaubale448@gmail.com, 2 rbd.scoe@gmail.com, 3 sdlokhande.scoe@sinhgad.edu Abstract The reliability of power electronics system such as three phase inverter is important in various applications. Different types of faults occur in it, which may influence the operation of system. Such faults require unexpected maintenance, which increases the cost of manufacturing. Therefore fault diagnosis of such devices plays vital role in industry. One possible fault that occurs in inverter is an open switch fault. This paper provides a new technique based on diagnostic variable which detects single as well as multiple open switch fault in three phase inverter. In this method, diagnostic variables are used to detect faulty phase. Along with these diagnostic variables, an average current of three phase inverter is used for the detection of single as well as multiple faulty switches. Key Words: Power electronics, open switch fault, diagnostic variables. --------------------------------------------------------------------***---------------------------------------------------------------------- 1. INTRODUCTION The voltage source inverter (VSI) is one of the most used circuit configurations for speed control of three-phase induction motors. The main objective of inverter is to produce an ac output waveform from a dc power supply. A fixed dc input voltage is given to the inverter and a controlled ac output voltage is obtained by adjusting the on and off periods of the inverter components. Three phase inverter provides a three-phase voltage source, where the amplitude, phase, and frequency of the voltages should always be controllable. The Pulse Width Modulation (PWM) is used to control the output voltage of inverter. Three phase PWM inverter is used in many industrial applications such as electric motor drives, UPS, active power filters, etc. Different types of unexpected faults may occurs in it. These AC drives systems are sensitive to different types of fault occurring at the input rectifier, or at the power inverter stage, or at the control sub system. In general, when one of these faults occurs, system may damage. The cost of these steps can be high. These inverter faults may influence the operation of whole system. It is necessary to avoid this harmful influence and to enhance the reliability of the system. Therefore, fault detection and diagnosis are needed. It is estimated that among all types of faults in variable- speed ac drives in industry, about 38% of the faults are due to failures of power devices [1]. Most of these inverters use insulated gate bipolar transistors (IGBTs) as the power device because of their high voltage and current ratings and ability to handle short-circuit currents for periods exceeding 10 μs. But they suffer failures due to excess electrical and thermal stress that are experienced in many applications. IGBT failures can be broadly classified as open-circuit faults, short-circuit faults, and intermittent gate-misfiring faults. There are several methods are available for detection of inverter faults. In [2] and [3], the technique using Park’s vector was proposed in which neural network is used for diagnosis. But this technique requires very complex pattern recognition algorithm. In [4] a fault detection using voltage sensors was proposed. This method is fast but it requires additional sensors. A method using a discrete Fourier transform (DFT) was proposed in [5]. In this method Fourier coefficients of current signal are used for fault diagnosis. In [6] and [7], neural network is used. This neural network is trained with the seven fault patterns which are calculated by average current Concordia vector trajectory. Most methods are used to find single switch fault and not multiple switch faults. In this paper, open-circuit fault in inverter is discussed. Presented method is able to detect single as well as multiple open switch fault in three phase inverter. The average absolute values of current are used to calculate diagnostic variables. Some characteristics are obtained with these diagnostic variables and average current of inverter which are used to detect faulty phase and faulty switches. This method is more robust to false alarm. 2. THREE PHASE INVERTER An inverter is an electronic device which converts Direct Current (DC) to Alternating Current (AC). This AC can be of any required voltage and frequency. The Variable Frequency Drive (VFD) mostly is of two types, Voltage Source Inverter (VSI) and Current Source Inverter (CSI). VSI has advantages like higher efficiencies, minimizing installation timing, eliminating interconnect power cabling costs, and reducing building floor space. Efficiencies are
  • 2. IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 _______________________________________________________________________________________ Volume: 02 Issue: 12 | Dec-2013, Available @ http://www.ijret.org 637 97% with high power factor through all load and speed ranges. Fig. 1 shows basic structure of a three phase voltage source inverter. In this model S1 to S6 are Insulated Gate Bipolar Transistors (IGBTs) which can be on or off Sinusoidal pulse width modulation (SPWM) is a common technique for controlling the switches. The average value of voltage fed to the load is controlled by turning the switch between supply and load on and off at a high frequency. Fig -1: Three Phase PWM Inverter The simplest way to generate a PWM signal is the intersective method, which requires a triangle waveform and a comparator. When the value of the reference signal is more than the modulation waveform, the PWM signal is in the high state, otherwise it is in the low state. In open circuit fault condition, the IGBT falls in the off state and remains in this situation regardless of the gate voltage value. Open-circuit fault occurs due to lifting of bonding wires caused by thermic cycling. It may be caused by a driver fault or a short-circuit-fault-induced IGBT rupture. Open circuit faults generally do not cause system shutdown, but degrade its performance. Therefore, these diagnostic methods can be used in device-fault-tolerant systems. 3. FAULT DIAGNOSTIC METHOD: 3.1 Park’s vector approach: The Park’s vector approach or dq transformation is mathematical transformation which simplifies three phase circuit. This method is used to transform three phase current of voltage source inverter ( , , ) into two phase current ( , ). The Park’s vector components are given by [1], = 2 3 − 1 √6 − 1 √6 (1) i = √ (i − i ) (2) Using dq transformation the current patterns can be obtained which indicates faulty situation of inverter current. It gives different six patterns. A normal operation is represented by a circle. If an open switch fault has occurred, there is a change in the phase current value at the location of fault. Therefore, a change in the circle shape represents the occurrence of an open fault condition. When fault occurs, circle becomes semicircle. Fig.2 shows dq transformation for normal and faulty phase current of three phase inverter. 3.2 Normalization of currents: The proposed method uses the dq transformation which transforms three phase current into two phase. This method requires only three phase currents as inputs and it does not require any extra sensors. (a) For normal operation Fig -2: DQ transformation Therefore, system complexity reduces. The normalization of measured current is used to overcome the problem of operating condition dependency and false diagnostics [8]. For normalization, dq transformation or Park’s vector approach is used to calculate Park’s vector modulus, given as ǀ ǀ= + (3) Where and are the Park’s vector components. The normalization is done by dividing three phase current by Park’s vector modulus. The normalized three phase current is given by, = ǀ ǀ (4) Where n=a,b,c. Therefore, assuming that the motor is fed by a healthy inverter generating a perfectly balanced three- phase sinusoidal current system = " # $ = %& sin()*+ + ,) = %& sin -)*+ − . / + ,0 = %& sin -)*+ + . / + ,0 1 (5) where %& is the currents maximum amplitude, )* is the motor currents frequency, and 3 is the initial phase angle. Because of this normalization process, the normalized motor phase currents will always take values within the range of -5 -4 -3 -2 -1 0 1 2 3 4 5 -5 -4 -3 -2 -1 0 1 2 3 4 5 DQ Transformation
  • 3. IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 _______________________________________________________________________________________ Volume: 02 Issue: 12 | Dec-2013, Available @ http://www.ijret.org 638 ± / , which is independent of the measured currents amplitude, = " 55 # 55 $ = / sin ()*+ + ,) = / sin ()*+ − . / + ,) = / sin ()*+ + . / + ,) 1 (6) 3.3 Average absolute value of currents: Average absolute values of three phase normalized currents < ǀ ǀ > are given by, )* 28 9 ǀ ǀ:+ ;< = > = 1 8 8 3 (7) 3.4 Diagnostic variables: The three diagnostic variables A (where n=a,b,c) are obtained from the errors of the normalized current’s average absolute values, given by A = B − 〈ǀ ǀ〉 (8) Where B is a constant value equivalent to the average absolute value of the normalized motor phase currents under normal operating conditions given by (7), that is B = . E / ≈ 0.5198 (9) The three diagnostic variables used for fault diagnosis because they have specific characteristics [9]. For normal operation, all the diagnostic variables will take values near to zero. If an inverter open-circuit fault is introduced, at least one of the diagnostic variables will takes positive value. But these variables only give the information about the faulty phase and not about faulty switches. Hence, along with diagnostic variables, current’s average value is used to detect faulty switches. J = " # $ K L A < 0 0 L 0 ≤ A < NO P L NO ≤ A < N Q L A ≥ N 1 (9) S = T U L 〈 〉 < 0 V L 〈 〉 > 0 1 (10) The values of J and S are used to generate a distinct fault signature. The threshold value NO is directly related to any fault detection, while N performs an important role in case of a double failure in the same inverter phase. Since the method is normalized, it is not required to adjust these values for each load and speed conditions. Table 1 gives different diagnostic signatures. Here, value of NO and N are considered as 0.00006 and 0.1996 respectively. 4. ARCHITECTURE OF FAULT DIAGNOSIS First step of fault diagnosis of three phase PWM inverter is to measure the three phase current and voltage. Measuring of current and voltage is done with different conditions. These measurements of current and signals are used for further processing. Table -1: Diagnostic signatures for faulty switch detection Faulty Switches Ea Eb Ec Ma Mb Mc S1 P N N L - - S2 P N N H - - S3 N P N - L - S4 N P N - H - S5 N N P - - L S6 N N P - - H S1,S2 D - - - - - S3,S4 - D - - - - S5,S6 - - D - - - S1,S3 P P N L L H S2,S4 P P N H H L S3,S5 N P P H L L S4,S6 N P P L H H S1,S5 P N P L H L S2,S6 P N P H L H Data acquisition board is used to collect these signals and transfer them from analog to digital signals. Because signal processing can be done in digital domain. These signals then import in MATLAB. The diagnostic variable method can be applied on these signals to find whether inverter signals are faulty or not. If so, then it will calculate location of faulty switch. Fig. 3 shows fault diagnostic system for real time application. Fig -3: Fault detection system for real time application. In this model, three phase inverter uses sinusoidal pulse width modulation technique. Input for inverter is 1 ph 40 V, 50 Hz. Output voltage of inverter is 0 to 25 AC. Load is
  • 4. IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 _______________________________________________________________________________________ Volume: 02 Issue: 12 | Dec-2013, Available @ http://www.ijret.org 639 resistive in star or delta. Output frequency is 0 to 50 Hz. Speed is controlled by frequency control. Data acquisition is the process of sampling signal that measure real world physical conditions and converting samples into digital numeric values that can be manipulated by a computer. It converts analog waveforms into digital values for processing. It includes sensors to convert physical parameter to electrical signal and signal conditioning circuitry to convert sensor signals into a form that can be converted to a digital form. 5. SIMULATION RESULTS For simulation results, inverter should be simulated in MATLAB for every fault mode. In this paper three distinct faulty operations are considered, a single IGBT open-circuit fault, a single-phase open-circuit fault (double fault in the same inverter leg), and a double switch open-circuit fault. Open switch fault can be introduced by removing respective gate signal of switches. a) Single IGBT open switch fault Fig. 4 shows the time-domain waveforms of the three phase inverter currents, the diagnostic variables and the normalized current’s average values. An IGBT open-circuit fault in switch S1 is introduced by removing its gate signal. When the fault in IGBT S1 occurs, the diagnostic variable of the corresponding phase A immediately increases, converging to a value of 0.23. The other two remaining errors will decrease until they reach a value of approximately −0.08. S1 is upper switch of phase a, therefore the current flows through bottom IGBT switch which is large negative average value of current. b) Single phase open circuit fault Fig. 5 shows simulation results for single phase open circuit fault in IGBT S1 and S2. In this case, the fault is introduced in S1 and S2 by removing corresponding gate signals. As a result, the diagnostic variable A will immediately increase to a final value of 0.51. Remaining two diagnostic variables will decreases, converging both to a value of about −0.18. c) Double power switches open circuit fault When the faults in transistors S1 and S3 are introduced, both the diagnostic variables eX and e will increase and reach values higher than kZ. The diagnostic variable of the normal phase will decreases to negative value. (a) (b) (c) Fig -4: Simulation results of (a) inverter three phase current,(b) diagnostic variables and (c) normalized currents average values when open switch fault in switch S1. (a) (b) (c) Fig -5: Simulation results of (a) inverter three phase current,(b) diagnostic variables and (c) normalized currents average values when open switch fault introduced in switch S1 and S2. CONCLUSION In this paper, a new diagnosis scheme for three phase inverter IGBT open switch faults is presented. In proposed method, three phase current of inverter is used as input to 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 -5 -4 -3 -2 -1 0 1 2 3 4 Three phase current of inverter Ia Ib Ic 0 1000 2000 3000 4000 5000 6000 7000 8000 -0.3 -0.2 -0.1 0 0.1 0.2 0.3 0.4 Diagnostic Variables ea eb ec 0 1000 2000 3000 4000 5000 6000 7000 8000 -0.8 -0.6 -0.4 -0.2 0 0.2 0.4 0.6 0.8 1 Normalized current average values <IaN> <IbN> <IcN> 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 -4 -3 -2 -1 0 1 2 3 4 Three phase current of inverter Ia Ib Ic 0 2000 4000 6000 8000 -0.2 -0.1 0 0.1 0.2 0.3 0.4 0.5 0.6 Diagnostic Variables ea eb ec 0 1000 2000 3000 4000 5000 6000 7000 8000 -0.8 -0.6 -0.4 -0.2 0 0.2 0.4 0.6 0.8 Normalized current average values <IaN> <IbN> <IcN>
  • 5. IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 _______________________________________________________________________________________ Volume: 02 Issue: 12 | Dec-2013, Available @ http://www.ijret.org 640 diagnostic method. This method avoids extra sensors and therefore reduces cost of manufacturing. The diagnostic variables provide the information about faulty phase. Along with this, average normalized three phase current, faulty switches can be detected. This method gives detection of single as well as multiple faulty switches. Because of normalization method, this method becomes independent on load level or motor speed. REFERENCES [1] F. W. Fuchs, “Some diagnosis methods for voltage source inverters in variable speed drives with induction machines—A survey,” in Proc. IEEE Ind. Electron. Conf., 2003, pp. 1378–1385. [2] K. Rothenhagen and F. W. Fuchs, “Performance of diagnosis methods for IGBT open circuit faults in voltage source active rectifiers,” IEEE PESC proc., 2004, pp.4348-4354. [3] A. M. S. Mendes, A. J. M. Cardoso, and E. S. Saraiva, “Voltage source inverter fault diagnosis in variable speed AC drives, by the average current Park's vector approach,” IEEE IEMDC Proc., 1999, pp.704-706. [4] R. L. A. Ribeiro, C. B. Jacobina, E. R. C. Silva, and A. M. N. Lima, “Fault detection of open-switch damage in voltage-fed PWM motor drive systems,” IEEE Trans. Power Electron., vol. 18, no. 2, pp. 587–593, Mar. 2003. [5] C. Kral and K. Kafka, “Power electronics monitoring for a controlled voltage source inverter drive with induction machines,” in Proc. IEEE 31st Annu. Power Electron. Spec. Conf., 2000, vol. 1, pp. 213–217. [6] D. Diallo, M. E. H. Benbouzid, D. Hamad, and X. Pierre, “Fault detection and diagnosis in an induction machine drive: a pattern recognition approach based on concordia stator mean current vector,” IEEE Trans. Energy Conv., vol. 20, no. 3, pp. 512-519, Sept. 2005. [7] J. H. Park, D. H. Kim, S. S. Kim, D. J. Lee, and M. G. Chun, “C-ANFIS based fault diagnosis for voltage-fed PWM motor drive systems,” IEEENAFIPS proc., 2004, pp.379-383 [8] J. O. Estima and A. J. M. Cardoso, “A novel diagnostic method for single power switch open-circuit faults in voltage-fed PWM motor drives,” in Proc. Int. Symp. Power Electron., Elect. Drives, Autom. Motion, Pisa, Italy, Jun. 14–16, 2010, pp. 535–540. [9] Jorge O. Estima and Antonio J. Marques Cardoso, “A New Approach for Real-Time Multiple Open-Circuit Fault Diagnosis in Voltage-Source Inverters”, IEEE Transactions on Industry Applications, Vol. 47, No. 6, Nov/Dec 2011.
  • 6. IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 ___________________________________________________________________________ ____________ Volume: 02 Issue: 12 | Dec-2013, Available @ http://www.ijret.org 641