A PROJECT REPORT ON
HUMAN MACHINE INTERFACE THROUGH
ELECTROMYOGRAPHY
Submitted by
ARJUN RAM
GAUTAM NATH
HITESH DEWASI
UNDER THE GUIDANCE OF PROF.
RITESH SARASHWAT
in partial fulfillment for the award of
BACHELOR OF TECHNOLOGY IN
ELECTRONICS AND COMMUNICATION ENGINEERING
FROM
RAJASTHAN TECHNICAL UNIVERSITY
DEPARTMENT OF
ELECTRONICS AND COMMUNICATION ENGINEERING
JODHPUR INSTITUTE OF ENGINEERING AND TECHNOLOGY MOGRA,
N. H. 62, PALI ROAD,JODHPUR-342802
NOVEMBER-2015
SESSION 2015-16
ii
JODHPUR INSTITUTE OF ENGINEERING & TECHNOLOGY
DEPARTMENT OF ELECTRONICS & COMMUNICATION
ENGINEERING
CERTIFICATE
This is to certify that the following students ARJUN RAM, GAUTAM NATH & HITESH
DEWASI have successfully completed the project Titled " HUMAN MACHINE INTERFACE
THROUGH ELECTROMYOGRAPHY” towards the partial fulfillment of Bachelor of Technology
in Electronics and Communications engineering of the Rajasthan Technical University during
academic year 2015 – 2016.
…..….………………… ………………………..
Project Associate Guide
(Prof. Lakshmi Chaudhary) (Prof. Ritesh Saraswat)
INTERNAL EXAMINER EXTERNAL EXAMINER
(Signature with Date) (Signature with Date)
iii
ACKNOWLEDGEMENT
At the very outset, I take this opportunity to express my sincere gratitude to all those who helped me
in the successful completion of my Project report.
We would like to make a number of acknowledgements to those who have helped us to prepare this
report.
We are highly grateful to Prof. O. P. VYAS, Dean (Engineering), JIET for proving us this opportunity to
carry out independent study on this topic.
The divine support given by our guide Prof. Ritesh Saraswat (B. Tech) , Prof. K. K. ARORA, HOD (M.
Tech) & Prof. (Dr.) HEMANT PUROHIT, HOD (B. Tech) Department of Electronics and
Communication Engineering, J.I.E.T, Jodhpur, without them the work would not be possible.
NAME ROLL NO
ARJUN RAM 12EJIEC705
GAUTAM NATH 12EJIEC714
HITESH DEWASI 12EJIEC720
iv
TABLE OF CONTENTS
CHAPTER PAGE NO.
Title Page…………………………………………………………………….i
Certificate………………………………….………………………………...ii
Acknowledgement…………………………….………………………….…iii
List Of figure………………………………………………………………..vi
Abstract……………………………………………………………….…….vii
Market Survey……………………………………………………………..viii
1. INTRODUCTION
1.1 Project Overview……………………………………….…………...1
1.2 Hardware Specification……………………………….…………….2
1.2.1 EMG portable Device……………………………….…...……..…2
1.2.2 EMG Electrode Type………………………………..…………….2
1.2.3 IC-INA 122 Op-Amp……………………………….……………..3
1.2.3.1 Description……………………………………….……………...4
1.2.3.2 Specification…………………………………………………….6
1.2.3.3 Application……………………………………….……………...6
1.2.4 IC- OPA 2241 Op-amp………………….…………………………7
1.2.4.1 Description……………………………………………………….7
1.2.4.2 Specification……………………………………………………...8
1.2.4.3 Application………………………………………………………..8
1.2.5 Battery………………………………………………………………9
1.2.5.1 Specification…………………………………………..…………..9
1.3 Software Specification………………………………………..……...10
2. STUDY & ANALYSIS
2.1 Need of Study………………….…………………………..………….11
2.2 Signal Recording………………………………………………..……..11
3. DESIGN
3.1 Methodology……………………………………….…………………12
..
3.2 Signal Processing……………………………………….…….………13
v
3.3 Circuit Design…………………………………………...………......15
3.4 PCB Layout…………………………………………..………..……15
3.5 Working……………………………………………….……….……16
4. APPLICATION…………………………………………………………..…18
5.1 ADVANTAGE……………………………………………………………..19
5.2 DISADVANTAGE……………………………………………………..….19
6. FUTURE SCOPE…………………………………………………….……..20
7. CONCLUSION……………………………………………………………..21
8. REFERENCE……………………………………………………….……....22
vi
LIST OFFIGURE
FIGURE NO. FIGURE NAME PAGE NO.
CHAPTER 1
1.2.1 EMG Portable Device 2
1.2.2.1 NMES Electrode 3
1.2.2.2 Metallic Disc Electrode 3
1.2.2.3 Nor axon’s gel Electrode 3
1.2.2.4 Use of Electrode 4
1.2.2.5 Fine Wire 4
1.2.3.1 Symbol Of Op-Amp 5
1.2.3.2 IC-INA 122 Op-Amp Pin Configuration 5
1.2.3.3 IC-INA 122 Op-Amp 6
1.2.4.1 IC-OPA 2241Pin Configuration 7
1.2.4.2 IC-OPA 2241 Op-Amp 8
1.2.5.1 Battery-9 Volt 9
1.3.1 Software Processing Analysis 10
1.3.2 EOG Signal Characteristics 10
CHAPTER 2
2.2.1 Electrode Placement 11
CHAPTER 3
3.2.1 System Design 13
3.2.2 Signal Processing 13
3.3.1 CIRCUIT DIAGRAM 15
3.4.1 PCB LAYOUT 15
3.4.2 Single Side PCB 16
3.5.1 EMG Signal 17
3.5.2 Electrode Placement 17
vii
ABSTRACT
Electromyography (EMG) signals can be used for clinical/biomedical applications, Evolvable
Hardware Chip (EHW) development, and modern human computer interaction. EMG signals acquired
from muscles require advanced methods for detection, decomposition, processing, and classification.
The purpose of this paper is to illustrate the various methodologies and algorithms for EMG signal
analysis to provide efficient and effective ways of understanding the signal and its nature. We further
point up some of the hardware implementations using EMG focusing on applications related to
prosthetic hand control, grasp recognition, and human computer interaction. A comparison study is also
given to show performance of various EMG signal analysis methods. This paper provides researchers
a good understanding of EMG signal and its analysis procedures. This knowledge will help them
develop more powerful, flexible, and efficient applications.
viii
MARKET SURVEY
SR.NO.
COMPONENT NAME
(MAJOR & MINOR) SPECIFICATION PRICE
1 IC 1 INA 122 Op-Amp 160
2 IC 2 OPA 2241 Op-Amp 160
3
Resistor
R1 (100 K ) 1
R2, R3 (10 K ) 1
R4 (1 K ) 1
4 Capacitor 1 uF,25 volt electrolytic 5
5 Battery 9 Volt 20
6 Ultrasound Gel ------- 25
7 Switch On/Off 10
8 Connector 3/2 Pin Connector 130
9 Electrode ECG Metallic/Disposal Electrode 700
1
CHAPTER 1
INTRODUCTION
1.1 PROJECT OVERVIEW:
Electromyography (EMG) is defined as the study of the muscular function through the
Analysis of the generated electric signals during muscular contractions. The potential
difference obtained in the fibers can be registered in the surface of the human body through
surface electrodes due to the biological tissues conducting properties. Our project studies the
muscular activity as an input
In order to control applications. A large set of target muscles are available so we can
interact widely with the computer. The main goal of the project is to provide tetraplegia
individuals the capability to control a portable device (especially to be able to write and
send SMS). In order to accomplish this task we monitories’ muscle activity through an
Electromyography
The recurrent and increasing electromyography study in medicine related areas led to a great
Scientific investment improve the myographic signal acquisition and analysis process.
These advances culminate with the possibility to use portable electromyography devices that
Communicate via wireless with a processing system. Portability makes it possible for any
individual the transport and use of an EMG device with great social acceptance (Costanzia et
al., 2004). EMG devices portability and reduced size easily conducted to its use in HCI
with work carried through in the area of Accessibility, Robotics, Mobile Computation and
Recognition of Gestures, among others. (Roy et al, 1994) present a gesture-based person
Portable device, process the digital signal and emulate certain events accordingly to the
Features detected. Being able to detect and to evaluate muscular activity in an individual
gives us the possibility to associate it with determined interface commands, thus having the
myographic signal as input. This kind of interaction can also be useful to full capable
individuals in a hands-busy situation, such as in a presentation or in a mobility context.
Machine interface for people with serious motor limitations due to cerebral paralysis. This
work, based on gestural recognition with biomechanic and bioelectric sensors, present
many motivating results being capable to differentiate gestures through the use of neural
networks. In the same scope, (Barreto et al., 1999) introduce a system that tries to offer the
users with serious motor limitations the possibility to use the traditional interfaces to
2
Point and select. This system associates face movements to mouse control, being sufficiently
similar to the system ”Tongue Point” (Salem and Zhai, 1997) but using myographic
signals. It is still in the accessibility context that (Erikssonet al., 1998) lean over prosthesis
control. As discussed in the introduction, a person’s brain wave -*patterns and muscle
stimulation can be measured and recorded using almost identical measurement techniques.
With accurate results, researches will soon be able to show a detailed direct Relation between
mental thought and physical motion, improve communications with lacking motor Skills, and
much more. But what are these measurement procedures and how are they carried out?
1.2 HARDWARE SPECIFICAION:
1.2.1 EMG Portable Device:
Our electromyography device collects samples at a 1000Hz sampling rate in 5
independent channels. It has a 110dB CMRR amplifier and a band pass filter between
25 and 500 Hz with gain 1000. It is a relatively small device (14cm * 8cm * 4cm) that can
be carried in a belt or pocket. It is a portable device which communicates by a Bluetooth
interface within a 100 meters range. To col- lect the signals we use surface differential
electrodes, with 1.5 cm radius (Gam boa et al., 2004)
Figure 1.2.1 EMG Portable Device
1.2.2 EMG ELECTRODE TYPES:
Most major limb and trunk muscle activity can be measured using surface electrode
techniques. For deeper, smaller, or overlaid muscles fine wire electrodes need to be used
to acquire intramuscular activities. For surface electrodes, simple platinum or silver disc
electrodes, pre-gelled Ag-AgCl electrodes, and wet-gel electrodes are commonly used.
The disc electrodes are reusable while the gel electrodes are single use. Distinction exists
between electrodes used for SEMG and those used for NMES and ETS. Whenever an
electrical stimulation is applied, the electrodes used must be properly designed to deliver
3
Such electrical stimulations otherwise the power density generated at the skin contact can
result in patient injury. Also, for the evaluation and treatment of incontinence, special
vaginal and anal probes are used to measure the pelvic floor muscle activities.
Fig 1.2.2.1 - NMES electrodes:
Fig 1.2.2.2:- Metallic disc electrodes
Fig 1.2.2.3 :- Noraxon’s gel electrodes: pre-gelled AgCl (1, 2) and wet-
gels (3, 4)
4
Fig 1.2.2.4:-Use of electrode
Fig 1.2.2.5:-Fine wire electrode
For all electrode types, additional measures can be taken to affix the electrode cabling to the
patient body to minimize movement artifacts. Regular adhesive tape, hook and loop fasteners,
and elastic straps are commonly used to secure cabling onto the body, but never the electrodes
as this will affect the readings when intramuscular EMG is required to look into the electrical
activity of deeper or overlaid muscles, thin and flexible fine wire electrodes are used.
The fine wire electrode is inserted into the muscle site of interest. The needle or steel
cannula is removed, and the electrode wires are connected to the steel spring adapters to
minimize movement artifacts.
1.2.3 IC-INA 122 OPAMP:
1.2.3.1 Description:
The INA122 is a precision instrumentation amplifier for accurate, low noise differential
signal acquisition. Its two-op-amp design provides excellent performance with very low
quiescent current, and is ideal for portable instrumentation and data acquisition systems. The
INA122 can be operated with single power supplies from 2.2V to 36V and
quiescent current is a mere 60mA. It can also be operated from dual supplies. By utilizing
an input level-shift network, input commonmode range extends to 0.1V below negative rail
(single supply ground). A single external resistor sets gain from 5V/V to
10000V/V. Laser trimming provides very low offset
5
Voltage (250mV max), offset voltage drift (3mV/°C max) and excellent common-mode
rejection.
Package options include 8-pin plastic DIP and SO-8 surface-mount packages. Both are
specified for the –40°C to +85°C extended industrial temperature range.
Fig 1.2.3.1:- Symbol of Op-amp
Fig 1.2.3.2:- IC-INA 122 Op-amp pin configuration
6
Fig1.2.3.3:-IC-INA 122 Op-amp
1.2.3.2 SPECIFICATION:
 LOW QUIESCENT CURRENT: 60mA
 WIDE POWER SUPPLY RANGE
 Single Supply: 2.2V to 36V
 Dual Supply: –0.9/+1.3V to ±18V
 COMMON-MODE RANGE TO (V–)–0.1V
 RAIL-TO-RAIL OUTPUT SWING
 LOW OFFSET VOLTAGE: 250mV max
 LOW OFFSET DRIFT: 3mV/°C max
 LOW INPUT BIAS CURRENT: 25nA max
 8-PIN DIP AND SO-8 SURFACE-MOUNT
1.2.3.3 APPLICATIONS:
 PORTABLE, BATTERY OPERATED SYSTEMS
 INDUSTRIAL SENSOR AMPLIFIER:
 Bridge, RTD, Thermocouple
 PHYSIOLOGICAL AMPLIFIER:
 USE IN ECG, EEG, EMG
 MULTI-CHANNEL DATA ACQUISITION
7
1.2.4 IC-OPA 2241 OPAMP:
1.2.4.1 DESCRIPTION:
The OPA241 series and OPA251 series are specifically designed for battery powered,
Portable applications. In addition to very low power consumption (25mA), these amplifiers
feature low offset voltage, rail-to-rail output swing, high common-mode rejection, and
high open-loop gain.
The OPA241 series is optimized for operation at low power supply voltage while the
OPA251 series is optimized for high power supplies. Both can operate from either single
(+2.7V to +36V) or dual supplies (±1.35V to ±18V). The input common-mode voltage
range extends 200mV below
The negative supply—ideal for single-supply applications. They are unity-gain stable and
can drive large capacitive loads. Special design considerations assure that these products
are easy to use. High performance is maintained as the amplifiers swing to their specified
limits. Because the initial Offset voltage (±250mV max) is so low, user adjustment is
usually not required. However, external trim pins are provided for special applications
(single versions only).
Fig 1.2.4.1:-Pin configuration of OPA2241 Op-amp
8
Fig 1.2.4.2:-IC-OPA 2241 OP-AMP
The OPA241 and OPA251 (single versions) are available in standard 8-pin DIP and SO-
8 surface-mount packages. The OPA2241 and OPA2251 (dual versions) come in 8-pin
DIP and SO-8 surface-mount packages. The OPA4241 and OPA4251 (quad versions) are
available in 14-pin DIP and SO-14 surface-mount packages. All are fully specified from
–40°C to +85°C and operate from –55°C to +125°C.
1.2.4.2 SPECIFICATION:
 Micro POWER: IQ = 25mA
 Single Supply Voltage
 Rail-to-Rail Output within 50mV
 Low Offset Voltage: 250uV max
 High Common-Mode Rejection: 124dB
 High Open-Loop Gain: 128dB
 Input Bias Current: -4nA
 Input Offset Current: 0.1nA
 Input Voltage Noise, f = 0.1Hz to 10Hz: 1uVp-p
 Common-Mode Voltage Range: -0.2V to (V+)-0.8V
1.2.4.3 APPLICATIONS:
 Battery Operated Instruments
 Portable Devices
 Use in Medical Instruments
 Use in Test Equipment
9
1.2.5 BATTERY:
Fig 1.2.5.1- 9 volt battery
1.2.5.1 SPECIFICATION:
 Nominal Voltage- 9 volt
 Impedance - 1,700 m-ohm @ 1 kHz
 Typical weight - 45 g (1.6 oz)
 Typical volume - 22.8 cm3 (1.4 in3)
 Terminals- Miniature snap
 Storage temperature range - 5ºC to 30ºC (41ºF to 86ºF)
 Operating temperature range - 20ºC to 54ºC (-4ºF to 130ºF)
 Designation - ANSI: 1604A IEC: 6LR6
10
10
1.3 SOFTWARE SPECIFICATION:
The software application analyzes the amplitude of the incoming signals, as the criteria
of an occurred event (opening/closing of the hand) are the threshold changes of the
first derivative. When this happens, an In order a processing by a computer to be
enabled, the analog data needs to be converted in a digital form. А multifunctional
USB device of National Instruments− NI USB-6009 (Fig. 6-3), has been used. The
EMG signal is fed to one of the analog inputs. The visualization and the data
processing are done through software
Fig. 1.3.1. Software for processing, analysis and gripper control
Similarly, the amplified signal is fed to an analog input of NI USB-6009 for
conversion and then the data are analyzed by Lab View software. As can be seen in
Fig. 1.3.2 -. Fragment of software for processing and analysis of EOG: EOG signal
characteristic (above); animation showing the actual position of the eyes (below)
11
11
CHAPTER-2
STUDY & ANALYSIS
2.1 NEED OF STUDY
Despite of the scope, all the projects refereed in- tend to present EMG as an input interface. In
this article we present our results and present user studies to go further and validate
electromyography de- vices as daily wearable interfaces. Our prototype ac- complishes the
control of various computer Applications and introduces a synergy between applications that ease
the text-entry task. In the next section we present our approach. The other sections are focused in
the user evaluations, results and discussion. In the last section we present the conclusions taken by
the user evaluations along with the work still to be done.
2.2 SIGNAL RECORDING:
In order to get useful information concerning the muscular activity it is necessary to carefully
analyze some aspects, from technical details at the electrode placement in the surface of the
human body to the points where this placement must be done. Several aspects influence the signal
quality: skin preparation, electrodes placement position, electrodes fixation, electrodes distance
and outside interferences (De Luca, 1997).We have discarded all the skin preparation techniques
since we don’t think they are appropriate to a user interface. Besides, after several tests we
observed good signal quality with small interference. However, to reinforce the surface electrodes
adherence we created an elastic band for the neck and two elastic bands for the forearm. We used
the 2cm distance between electrodes which guarantees a solution of commitment (Figure 2),
collecting the signal of a significant portion of the muscle and restricting, simultaneously, the
undesired signals to insignificant values (De Luca, 1997).
Figure 2.2.1: Electrodes placement
12
12
CHAPTER 3
DESIGN
3.1 METHODOLOGY
We conducted several experiments to assess the us- ability of myographic activity as as interaction
modal- ity. For that purpose, besides the experiments to vali- date the interaction speed and
accuracy, we focused our attention in the interface robustness as a daily wearable interface.
a) Clicking Start Button, where a timer is activated;
b) Moving the cursor towards the Stop button, with any trajectory;
c) Clicking Stop Button, and the time is presented to the user and saved. The Start Button
dimensions are always 8, 5 x 8,5mm but there are four Stop Button dimensions (8.5 x 8.5mm; 12.5 x
12.5mm; 17 x 17mm; 22 x 22mm). We made 80 evaluations, 20 of each for every Stop Button
size. The Start Button changed between the four corners. The users were equipped with two pairs
of electrodes in each forearm (four directions) and another pair near one eye to detect blinking
13
13
3.2 SIGNAL PROCESSING:
Figure 3.2.1: System Design
The pre-processing is composed by some basic procedures that prepare the signal to be smoothed.
The signal received from the electromyography device has
Figure 3.2.2: Signal Processing
14
14
As mentioned before, the useful frequency range is between 0 Hz and 500 Hz. So filtering the raw
signal is recommended to limit the signal’s frequency range to the desired range. Van Boxtel in
[vB08] found that a band-pass frequency range of 20 Hz to 500 Hz appeared to be adequate
because there was a negligible contribution of higher frequency components to the EMG signal.
In [CJDLR10] De Luca et al. are recommending to set the low-pass filter corner frequency to 400-
450 Hz, where the high end of the SEMG frequency spectrum is expected. Various
recommendations for the high-pass filter corner frequency can be found in literature. All the
recommendations are between 5 Hz and 20 Hz. SENIAM recommends to set the high-pass filter
corner frequency to 10 - 20Hz For several decades it has been commonly accepted that the
preferred manner for processing the EMG signal after filtering was to calculate the integrated
rectified signal. This was done by full-wave rectifying the EMG signal, integrating the signal over
a specified interval of time and subsequently forming a time series of the integrated values. Full-
wave rectification means the conversion of the input waveform to one of constant polarity (positive
or negative) at its output. This approach of rectifying and integrating became widespread since it
is possible to make these calculations accurately and inexpensively with the limited electronics
technology of earlier decades. Equation (2.2) shows how the calculation of the integrated rectified
signal is
15
15
3.3 CIRCUIT DIAGRAM:
Fig 3.3.1:-Circuit diagram of Human Machine Interface through Electromyography
3.4 PCB LAYOUT
Fig. 3.4.1: Component layout for the PCB
16
16
Fig. 3.4.2: An actual-size, single-side PCB for HMI through EMG
3.5 WORKING
The circuit diagram of HMI through EMG is shown in Fig. 3. Starting from the left, two electrodes
attached to a muscle are connected to a single-supply instrumentation amplifier INA122 (IC1),
which amplifies the voltage difference between the two electrodes, rejecting any signal that is
common to both—thereby removing much of the noise and 50Hz AC EMI. Resistor R1 determines
the gain of the output of IC1.
It is difficult to deal with the bi-polar nature of the bio-signals. To overcome this problem, we use
virtual-ground topology or split-rail topology, which splits the main power rail into two rails—one
having Vcc and the other with half of Vcc (virtual ground). The created virtual ground acts as the
pseudo-zero voltage and thus makes the output to swing between 0 and Vcc with virtual ground
as zero volts, which makes the entire portion of the EMG wave available and also in the positive
range only, thus making this topology ideal for interfacing with digital systems or microcontrollers.
IC1 is specifically designed for single-supply operations, for which it includes voltage translators
and overvoltage protection. The electrodes are directly attached to the muscle. Prior to attaching
the electrodes, clean the patient’s skin with alcohol for removing dirt and apply an ultrasound gel.
Two electrodes are attached over the muscle of interest and the third one (reference) is connected
17
17
to an area preferably in the joints where there are less muscles. The reference electrode should
only be connected at pin 3 of CON1. It is vital as it provides the common-mode signal.
The reference is connected to the virtual ground and pin 5 (Vref) of IC1, so care must be taken to
isolate the patient from ground. The patient must not touch any grounded metal, which can cause
drainage of common-mode voltage and thus raise the amplitude of the output and inject a lot of
noise. The output from instrumentation amplifier IC1 is fed to a non-inverting amplifier built
around OPA2241 (IC2) via capacitor C1, which removes the DC offset from the electrodes. The
amplified output signal from IC2 is sent to the PC oscilloscope via an audio jack to get the display
of the waveform.
Fig.3.5.1-EMG Signal on the Pc based oscilloscope, Fig 3.5.2 :-Electrode Placement
18
18
CHAPTER 4
APPLICATION
1. Skin placement.
2. Avoid movement of electrodes by using straps or tape to
firmly secure electrode I place.
3. Avoid bending of leads, place leads pointing in the
direction that you want the wire to Continue in. (e.g., for
electrodes placed on an extremity, have the lead pointing
towards The proximal end of the extremity so that the wire
will not have to be bent in order to go In the proximal
direction.)
4. Avoid any stress on the wires by making sure that the
wires are loose underneath the Tape or wrap that is holding
them in place. Be sure to check when the wires cross the
Joint that once the joint is fully extended the wires are not
drawn taunt.
5. Avoid placing electrodes over scars.
6. Measured potential.
7. Measuring skeletal muscle electrical output during physical activity
8. Sports medicine
9. EMG signals can be used for variety of applications like clinical/biomedical
10. EMG can be used to sense isometric muscular activity
11. To measure the force of the isometric muscle contraction, a surface EMG was used
12. The idea of controlling machines with levers and knobs. Instead, they plan to have machines
respond directly to human gestures.
19
19
CHAPTER 5
5.1 ADVANTAGE
 Extremely sensitive
 Record single muscle activity
 Access to deep musculature
 Little cross-talk concern
 Surface EMG Recording Provide a safe.
 Easy and noninvasive method
5.2DISADVANTAGE
 Extremely sensitive
 Requires medical personnel, certification
 Repositioning nearly impossible
 Detection area may not be representative of entire muscle
20
20
CHAPTER 6
FUTURE SCOPE
It is intended to develop software environment for computer’s mouse control and cursor
movement, done by eye movements. Such a development could be useful for people with
disabilities, allowing them access to a computer. The application can easily be extended to allow
control of various electromechanical devices (wheelchairs). At the date of submission of the paper
a project was launched for realization of artificial, five-finger hand which will be controlled by
registered EMG potentials. In the near future we will see higher function prosthetics, brain
computer interfaces with more control, voice recognition and camera gesture recognition being
used more. Although not quite the death of the everyday mouse and keyboard, we will dentally
start to see new types of technology integrated into our everyday lives. Portable devices are
becoming smaller and more complex, so we should start seeing growth in wearable interfaces.
Robots, and the way we interact with them is already beginning to change, we are in the computer
era, but soon we will be in the robotic era.
Nano technology has provided a new wave of advancements, but these have yet to be fully utilized
in HMI, Nano technology has an important future role to play. Nano machines and super batteries
haven't fully materialized, so we have something to look forward to. There is also the potential of
Quantum Computing which will unleash an entirely new level of processor, with amazing speeds.
HMI technology is impressive now, but in the future there will be nothing like it. It won't matter
who you are, what language you speak, or what disability you have, the variety of technology will
cater for everyone. This document has provided an overview of what HMI , and has shown you a
glimpse of what the future might hold. One thing that is certain is that technologies will begin to
converge, devices will combine functionality, new levels of sensor fusions will be created, and all
this for one purpose, to enhance our Human Machine Interaction. The technology involved in HMI
21
21
CHAPTER 7
CONCLUSION
The EMG/EEG-based Human–Computer Interaction system presented represents a potential alternative for
the communication of individuals with severe motor disabilities and their computers. Because the system
commands cursor movements on the basis of detection and classification of EMG signals, its operation is
relatively simple for the user. Use of the interface only requires the voluntary contraction of a set of cranial
muscles, requiring little training on the part of the subject. The operation of the system is possible due to
the difference in the spectral composition of EMG signals generated by contraction of different cranial
muscles. Thus, the novel classification approach allows the on-line separation of EMG signals caused by
the contraction of different muscles, based on the real-time estimation of their power spectra. In our
evaluation of the interface, six experimental subjects were able to drive the computer cursor from the
Screen corners to the center and perform a click at each end of that trajectory in an average of 16 seconds.
This level of performance achieved by untrained subjects reveals that this interface can be employed for
such applications as web browsing and appliance control through appropriate hardware/software setups.
In comparison with other unassisted interfaces for users with disabilities, the EMG/EEG interface proposed
has the potential to be more affordable and portable then others, such as eye-gaze tracking devices
22
22
REFERENCES
1. http://www.kevinwarwick.com/
2. Basmajian JV, et al. Computers in Electromyography. Butterworths, 1975
3. Shavi R, Green N. Ensemble averaging of locomotors electromyography patterns
using interpolation. Med & Biol Eng & Comput, 21: 573-578, 1983.
4. De Luca. C.J. (1997) The Use of Surface Electromyography in Biomechanics. Journal
of Applied Biomechanics, Volume 13, Pages 135-163, 1997
5. www.datasheets4u.com
6. http://www.electronicsforyou.com
7. Kuiken, A. & Lipschutz, R. (2008) A strategy for identifying locomotion modes using
surface electromyography
8. https://www.grasstelefactor.com/products/clinsystems/cmeeg1.html
9. http://www.futurehealth.org/a-2.htm
10. http://www.biosemi.com/publications/artikel4.htm

Weitere ähnliche Inhalte

Was ist angesagt?

IRJET- Brain Comuter Interface-A Survey
IRJET- Brain Comuter Interface-A SurveyIRJET- Brain Comuter Interface-A Survey
IRJET- Brain Comuter Interface-A SurveyIRJET Journal
 
International Journal of Engineering Research and Development (IJERD)
International Journal of Engineering Research and Development (IJERD)International Journal of Engineering Research and Development (IJERD)
International Journal of Engineering Research and Development (IJERD)IJERD Editor
 
Finger Movement Based Wearable Communication & Navigation Aid for partially d...
Finger Movement Based Wearable Communication & Navigation Aid for partially d...Finger Movement Based Wearable Communication & Navigation Aid for partially d...
Finger Movement Based Wearable Communication & Navigation Aid for partially d...IJERA Editor
 
Design and Implementation of Brain Computer Interface for Wheelchair control
Design and Implementation of Brain Computer Interface for Wheelchair controlDesign and Implementation of Brain Computer Interface for Wheelchair control
Design and Implementation of Brain Computer Interface for Wheelchair controlIRJET Journal
 
IRJET- Detection of Schizophrenia Disorder in Brain MR Images using Segmentat...
IRJET- Detection of Schizophrenia Disorder in Brain MR Images using Segmentat...IRJET- Detection of Schizophrenia Disorder in Brain MR Images using Segmentat...
IRJET- Detection of Schizophrenia Disorder in Brain MR Images using Segmentat...IRJET Journal
 
IRJET- Implementation of Continues Body Monitoring System with Wireless B...
IRJET-  	  Implementation of Continues Body Monitoring System with Wireless B...IRJET-  	  Implementation of Continues Body Monitoring System with Wireless B...
IRJET- Implementation of Continues Body Monitoring System with Wireless B...IRJET Journal
 
Smart blind stick book
Smart blind stick bookSmart blind stick book
Smart blind stick bookAhmed Moawad
 
A Real Time Electrocardiogram (ECG) Device for Cardiac Patients
A Real Time Electrocardiogram (ECG) Device for Cardiac PatientsA Real Time Electrocardiogram (ECG) Device for Cardiac Patients
A Real Time Electrocardiogram (ECG) Device for Cardiac PatientsIJERD Editor
 
Implementation and demonstration of li fi technology
Implementation and demonstration of li fi technologyImplementation and demonstration of li fi technology
Implementation and demonstration of li fi technologyeSAT Journals
 
A Review on Motor Imagery Signal Classification for BCI
A Review on Motor Imagery Signal Classification for BCIA Review on Motor Imagery Signal Classification for BCI
A Review on Motor Imagery Signal Classification for BCICSCJournals
 
Obstacle detection in images
Obstacle detection in imagesObstacle detection in images
Obstacle detection in imageshasangamethmal
 
IRJET - FPGA based Electrocardiogram (ECG) Signal Analysis using Linear Phase...
IRJET - FPGA based Electrocardiogram (ECG) Signal Analysis using Linear Phase...IRJET - FPGA based Electrocardiogram (ECG) Signal Analysis using Linear Phase...
IRJET - FPGA based Electrocardiogram (ECG) Signal Analysis using Linear Phase...IRJET Journal
 
Brainwave Controlled Wheelchair (BCW)
Brainwave Controlled Wheelchair (BCW)Brainwave Controlled Wheelchair (BCW)
Brainwave Controlled Wheelchair (BCW)vivatechijri
 
Appliance switching using eye movement for paralyzed people
Appliance switching using eye movement for paralyzed peopleAppliance switching using eye movement for paralyzed people
Appliance switching using eye movement for paralyzed peopleiaemedu
 
IRJET- Development of Data Transmission using Smart Sensing Technology for St...
IRJET- Development of Data Transmission using Smart Sensing Technology for St...IRJET- Development of Data Transmission using Smart Sensing Technology for St...
IRJET- Development of Data Transmission using Smart Sensing Technology for St...IRJET Journal
 
IRJET- Smart Guide Stick For Blind
IRJET- Smart Guide Stick For BlindIRJET- Smart Guide Stick For Blind
IRJET- Smart Guide Stick For BlindIRJET Journal
 

Was ist angesagt? (20)

IRJET- Brain Comuter Interface-A Survey
IRJET- Brain Comuter Interface-A SurveyIRJET- Brain Comuter Interface-A Survey
IRJET- Brain Comuter Interface-A Survey
 
International Journal of Engineering Research and Development (IJERD)
International Journal of Engineering Research and Development (IJERD)International Journal of Engineering Research and Development (IJERD)
International Journal of Engineering Research and Development (IJERD)
 
Finger Movement Based Wearable Communication & Navigation Aid for partially d...
Finger Movement Based Wearable Communication & Navigation Aid for partially d...Finger Movement Based Wearable Communication & Navigation Aid for partially d...
Finger Movement Based Wearable Communication & Navigation Aid for partially d...
 
Design and Implementation of Brain Computer Interface for Wheelchair control
Design and Implementation of Brain Computer Interface for Wheelchair controlDesign and Implementation of Brain Computer Interface for Wheelchair control
Design and Implementation of Brain Computer Interface for Wheelchair control
 
IRJET- Detection of Schizophrenia Disorder in Brain MR Images using Segmentat...
IRJET- Detection of Schizophrenia Disorder in Brain MR Images using Segmentat...IRJET- Detection of Schizophrenia Disorder in Brain MR Images using Segmentat...
IRJET- Detection of Schizophrenia Disorder in Brain MR Images using Segmentat...
 
IRJET- Implementation of Continues Body Monitoring System with Wireless B...
IRJET-  	  Implementation of Continues Body Monitoring System with Wireless B...IRJET-  	  Implementation of Continues Body Monitoring System with Wireless B...
IRJET- Implementation of Continues Body Monitoring System with Wireless B...
 
1569736195
15697361951569736195
1569736195
 
Smart blind stick book
Smart blind stick bookSmart blind stick book
Smart blind stick book
 
Seminar
SeminarSeminar
Seminar
 
A Real Time Electrocardiogram (ECG) Device for Cardiac Patients
A Real Time Electrocardiogram (ECG) Device for Cardiac PatientsA Real Time Electrocardiogram (ECG) Device for Cardiac Patients
A Real Time Electrocardiogram (ECG) Device for Cardiac Patients
 
Implementation and demonstration of li fi technology
Implementation and demonstration of li fi technologyImplementation and demonstration of li fi technology
Implementation and demonstration of li fi technology
 
A Review on Motor Imagery Signal Classification for BCI
A Review on Motor Imagery Signal Classification for BCIA Review on Motor Imagery Signal Classification for BCI
A Review on Motor Imagery Signal Classification for BCI
 
Rect-O-Back
Rect-O-BackRect-O-Back
Rect-O-Back
 
Obstacle detection in images
Obstacle detection in imagesObstacle detection in images
Obstacle detection in images
 
IRJET - FPGA based Electrocardiogram (ECG) Signal Analysis using Linear Phase...
IRJET - FPGA based Electrocardiogram (ECG) Signal Analysis using Linear Phase...IRJET - FPGA based Electrocardiogram (ECG) Signal Analysis using Linear Phase...
IRJET - FPGA based Electrocardiogram (ECG) Signal Analysis using Linear Phase...
 
Brainwave Controlled Wheelchair (BCW)
Brainwave Controlled Wheelchair (BCW)Brainwave Controlled Wheelchair (BCW)
Brainwave Controlled Wheelchair (BCW)
 
Appliance switching using eye movement for paralyzed people
Appliance switching using eye movement for paralyzed peopleAppliance switching using eye movement for paralyzed people
Appliance switching using eye movement for paralyzed people
 
IRJET- Development of Data Transmission using Smart Sensing Technology for St...
IRJET- Development of Data Transmission using Smart Sensing Technology for St...IRJET- Development of Data Transmission using Smart Sensing Technology for St...
IRJET- Development of Data Transmission using Smart Sensing Technology for St...
 
published paper
published paperpublished paper
published paper
 
IRJET- Smart Guide Stick For Blind
IRJET- Smart Guide Stick For BlindIRJET- Smart Guide Stick For Blind
IRJET- Smart Guide Stick For Blind
 

Ähnlich wie HUMAN MACHINE INTERFACE THROUGH ELECTROMYOGRAPHY MINOR PROJECT FULL REPORT

A nonlinearities inverse distance weighting spatial interpolation approach ap...
A nonlinearities inverse distance weighting spatial interpolation approach ap...A nonlinearities inverse distance weighting spatial interpolation approach ap...
A nonlinearities inverse distance weighting spatial interpolation approach ap...IJECEIAES
 
A Smart Handheld Measuring and Testing Electronic Device with Touch Screen
A Smart Handheld Measuring and Testing Electronic Device with Touch ScreenA Smart Handheld Measuring and Testing Electronic Device with Touch Screen
A Smart Handheld Measuring and Testing Electronic Device with Touch ScreenIJTET Journal
 
IRJET - Real Time Muscle Fatigue Monitoring using IoT Cloud Computing
IRJET - Real Time Muscle Fatigue Monitoring using IoT Cloud ComputingIRJET - Real Time Muscle Fatigue Monitoring using IoT Cloud Computing
IRJET - Real Time Muscle Fatigue Monitoring using IoT Cloud ComputingIRJET Journal
 
Survey on Red Tacton Technology for Human Area Network
Survey on Red Tacton Technology for Human Area NetworkSurvey on Red Tacton Technology for Human Area Network
Survey on Red Tacton Technology for Human Area NetworkIOSR Journals
 
WAVELET DECOMPOSITION METHOD BASED AUTOMATED DIAGNOSIS OF MUSCLE DISEASES
WAVELET DECOMPOSITION METHOD BASED AUTOMATED DIAGNOSIS OF MUSCLE DISEASESWAVELET DECOMPOSITION METHOD BASED AUTOMATED DIAGNOSIS OF MUSCLE DISEASES
WAVELET DECOMPOSITION METHOD BASED AUTOMATED DIAGNOSIS OF MUSCLE DISEASESIRJET Journal
 
Design of single channel portable eeg
Design of single channel portable eegDesign of single channel portable eeg
Design of single channel portable eegijbesjournal
 
62 ijtet14003 pdf-libre
62 ijtet14003 pdf-libre62 ijtet14003 pdf-libre
62 ijtet14003 pdf-libreIJTET Journal
 
Prosthetic Arm for Amputees
Prosthetic Arm for AmputeesProsthetic Arm for Amputees
Prosthetic Arm for Amputeesvivatechijri
 
IRJET- IoT Based Home Automation And Health Monitoring System for Physically ...
IRJET- IoT Based Home Automation And Health Monitoring System for Physically ...IRJET- IoT Based Home Automation And Health Monitoring System for Physically ...
IRJET- IoT Based Home Automation And Health Monitoring System for Physically ...IRJET Journal
 
LPC2138 Based Temperature Compensated Ultrasonic Ranging For Blind Person
LPC2138 Based Temperature Compensated Ultrasonic Ranging For Blind PersonLPC2138 Based Temperature Compensated Ultrasonic Ranging For Blind Person
LPC2138 Based Temperature Compensated Ultrasonic Ranging For Blind Personpaperpublications3
 
Accelerometer and EOG Based Wireless Gesture Controlled Robotic Arm
Accelerometer and EOG Based Wireless Gesture Controlled Robotic ArmAccelerometer and EOG Based Wireless Gesture Controlled Robotic Arm
Accelerometer and EOG Based Wireless Gesture Controlled Robotic ArmIJMER
 
Microcontroller Based Obstacle Detection Device Using Voice Signal for the V...
Microcontroller Based Obstacle Detection Device Using Voice  Signal for the V...Microcontroller Based Obstacle Detection Device Using Voice  Signal for the V...
Microcontroller Based Obstacle Detection Device Using Voice Signal for the V...IJMER
 
Iaetsd real time implementation of railway
Iaetsd real time implementation of railwayIaetsd real time implementation of railway
Iaetsd real time implementation of railwayIaetsd Iaetsd
 
Bionic Arm Using EMG Processing
Bionic Arm Using EMG ProcessingBionic Arm Using EMG Processing
Bionic Arm Using EMG Processingbiomedicz
 
IRJET- Motion Based Message Conveyor for Physically Disabled People
IRJET-  	  Motion Based Message Conveyor for Physically Disabled PeopleIRJET-  	  Motion Based Message Conveyor for Physically Disabled People
IRJET- Motion Based Message Conveyor for Physically Disabled PeopleIRJET Journal
 

Ähnlich wie HUMAN MACHINE INTERFACE THROUGH ELECTROMYOGRAPHY MINOR PROJECT FULL REPORT (20)

A nonlinearities inverse distance weighting spatial interpolation approach ap...
A nonlinearities inverse distance weighting spatial interpolation approach ap...A nonlinearities inverse distance weighting spatial interpolation approach ap...
A nonlinearities inverse distance weighting spatial interpolation approach ap...
 
Medical-Robotics
Medical-RoboticsMedical-Robotics
Medical-Robotics
 
A Smart Handheld Measuring and Testing Electronic Device with Touch Screen
A Smart Handheld Measuring and Testing Electronic Device with Touch ScreenA Smart Handheld Measuring and Testing Electronic Device with Touch Screen
A Smart Handheld Measuring and Testing Electronic Device with Touch Screen
 
IRJET - Real Time Muscle Fatigue Monitoring using IoT Cloud Computing
IRJET - Real Time Muscle Fatigue Monitoring using IoT Cloud ComputingIRJET - Real Time Muscle Fatigue Monitoring using IoT Cloud Computing
IRJET - Real Time Muscle Fatigue Monitoring using IoT Cloud Computing
 
Survey on Red Tacton Technology for Human Area Network
Survey on Red Tacton Technology for Human Area NetworkSurvey on Red Tacton Technology for Human Area Network
Survey on Red Tacton Technology for Human Area Network
 
WAVELET DECOMPOSITION METHOD BASED AUTOMATED DIAGNOSIS OF MUSCLE DISEASES
WAVELET DECOMPOSITION METHOD BASED AUTOMATED DIAGNOSIS OF MUSCLE DISEASESWAVELET DECOMPOSITION METHOD BASED AUTOMATED DIAGNOSIS OF MUSCLE DISEASES
WAVELET DECOMPOSITION METHOD BASED AUTOMATED DIAGNOSIS OF MUSCLE DISEASES
 
Design of single channel portable eeg
Design of single channel portable eegDesign of single channel portable eeg
Design of single channel portable eeg
 
62 ijtet14003 pdf-libre
62 ijtet14003 pdf-libre62 ijtet14003 pdf-libre
62 ijtet14003 pdf-libre
 
Prosthetic Arm for Amputees
Prosthetic Arm for AmputeesProsthetic Arm for Amputees
Prosthetic Arm for Amputees
 
IRJET- IoT Based Home Automation And Health Monitoring System for Physically ...
IRJET- IoT Based Home Automation And Health Monitoring System for Physically ...IRJET- IoT Based Home Automation And Health Monitoring System for Physically ...
IRJET- IoT Based Home Automation And Health Monitoring System for Physically ...
 
LPC2138 Based Temperature Compensated Ultrasonic Ranging For Blind Person
LPC2138 Based Temperature Compensated Ultrasonic Ranging For Blind PersonLPC2138 Based Temperature Compensated Ultrasonic Ranging For Blind Person
LPC2138 Based Temperature Compensated Ultrasonic Ranging For Blind Person
 
Accelerometer and EOG Based Wireless Gesture Controlled Robotic Arm
Accelerometer and EOG Based Wireless Gesture Controlled Robotic ArmAccelerometer and EOG Based Wireless Gesture Controlled Robotic Arm
Accelerometer and EOG Based Wireless Gesture Controlled Robotic Arm
 
Microcontroller Based Obstacle Detection Device Using Voice Signal for the V...
Microcontroller Based Obstacle Detection Device Using Voice  Signal for the V...Microcontroller Based Obstacle Detection Device Using Voice  Signal for the V...
Microcontroller Based Obstacle Detection Device Using Voice Signal for the V...
 
Iaetsd real time implementation of railway
Iaetsd real time implementation of railwayIaetsd real time implementation of railway
Iaetsd real time implementation of railway
 
Redtacton ppt
Redtacton pptRedtacton ppt
Redtacton ppt
 
Ultrasonic based distance meter
Ultrasonic based distance meterUltrasonic based distance meter
Ultrasonic based distance meter
 
Bionic Arm Using EMG Processing
Bionic Arm Using EMG ProcessingBionic Arm Using EMG Processing
Bionic Arm Using EMG Processing
 
IRJET- Motion Based Message Conveyor for Physically Disabled People
IRJET-  	  Motion Based Message Conveyor for Physically Disabled PeopleIRJET-  	  Motion Based Message Conveyor for Physically Disabled People
IRJET- Motion Based Message Conveyor for Physically Disabled People
 
BATCH 1.pptx
BATCH 1.pptxBATCH 1.pptx
BATCH 1.pptx
 
B04420812
B04420812B04420812
B04420812
 

Kürzlich hochgeladen

ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdfONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdfKamal Acharya
 
UNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its PerformanceUNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its Performancesivaprakash250
 
University management System project report..pdf
University management System project report..pdfUniversity management System project report..pdf
University management System project report..pdfKamal Acharya
 
Block diagram reduction techniques in control systems.ppt
Block diagram reduction techniques in control systems.pptBlock diagram reduction techniques in control systems.ppt
Block diagram reduction techniques in control systems.pptNANDHAKUMARA10
 
Hostel management system project report..pdf
Hostel management system project report..pdfHostel management system project report..pdf
Hostel management system project report..pdfKamal Acharya
 
Bhosari ( Call Girls ) Pune 6297143586 Hot Model With Sexy Bhabi Ready For ...
Bhosari ( Call Girls ) Pune  6297143586  Hot Model With Sexy Bhabi Ready For ...Bhosari ( Call Girls ) Pune  6297143586  Hot Model With Sexy Bhabi Ready For ...
Bhosari ( Call Girls ) Pune 6297143586 Hot Model With Sexy Bhabi Ready For ...tanu pandey
 
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...roncy bisnoi
 
Work-Permit-Receiver-in-Saudi-Aramco.pptx
Work-Permit-Receiver-in-Saudi-Aramco.pptxWork-Permit-Receiver-in-Saudi-Aramco.pptx
Work-Permit-Receiver-in-Saudi-Aramco.pptxJuliansyahHarahap1
 
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...Arindam Chakraborty, Ph.D., P.E. (CA, TX)
 
Introduction to Serverless with AWS Lambda
Introduction to Serverless with AWS LambdaIntroduction to Serverless with AWS Lambda
Introduction to Serverless with AWS LambdaOmar Fathy
 
Standard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power PlayStandard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power PlayEpec Engineered Technologies
 
Thermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - VThermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - VDineshKumar4165
 
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night StandCall Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Standamitlee9823
 
A Study of Urban Area Plan for Pabna Municipality
A Study of Urban Area Plan for Pabna MunicipalityA Study of Urban Area Plan for Pabna Municipality
A Study of Urban Area Plan for Pabna MunicipalityMorshed Ahmed Rahath
 
Top Rated Call Girls In chittoor 📱 {7001035870} VIP Escorts chittoor
Top Rated Call Girls In chittoor 📱 {7001035870} VIP Escorts chittoorTop Rated Call Girls In chittoor 📱 {7001035870} VIP Escorts chittoor
Top Rated Call Girls In chittoor 📱 {7001035870} VIP Escorts chittoordharasingh5698
 
DC MACHINE-Motoring and generation, Armature circuit equation
DC MACHINE-Motoring and generation, Armature circuit equationDC MACHINE-Motoring and generation, Armature circuit equation
DC MACHINE-Motoring and generation, Armature circuit equationBhangaleSonal
 

Kürzlich hochgeladen (20)

ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdfONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
 
UNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its PerformanceUNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its Performance
 
University management System project report..pdf
University management System project report..pdfUniversity management System project report..pdf
University management System project report..pdf
 
Block diagram reduction techniques in control systems.ppt
Block diagram reduction techniques in control systems.pptBlock diagram reduction techniques in control systems.ppt
Block diagram reduction techniques in control systems.ppt
 
Hostel management system project report..pdf
Hostel management system project report..pdfHostel management system project report..pdf
Hostel management system project report..pdf
 
Bhosari ( Call Girls ) Pune 6297143586 Hot Model With Sexy Bhabi Ready For ...
Bhosari ( Call Girls ) Pune  6297143586  Hot Model With Sexy Bhabi Ready For ...Bhosari ( Call Girls ) Pune  6297143586  Hot Model With Sexy Bhabi Ready For ...
Bhosari ( Call Girls ) Pune 6297143586 Hot Model With Sexy Bhabi Ready For ...
 
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
 
FEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced Loads
FEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced LoadsFEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced Loads
FEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced Loads
 
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
 
Work-Permit-Receiver-in-Saudi-Aramco.pptx
Work-Permit-Receiver-in-Saudi-Aramco.pptxWork-Permit-Receiver-in-Saudi-Aramco.pptx
Work-Permit-Receiver-in-Saudi-Aramco.pptx
 
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
 
Introduction to Serverless with AWS Lambda
Introduction to Serverless with AWS LambdaIntroduction to Serverless with AWS Lambda
Introduction to Serverless with AWS Lambda
 
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar ≼🔝 Delhi door step de...
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar  ≼🔝 Delhi door step de...Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar  ≼🔝 Delhi door step de...
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar ≼🔝 Delhi door step de...
 
Standard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power PlayStandard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power Play
 
Thermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - VThermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - V
 
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night StandCall Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
 
A Study of Urban Area Plan for Pabna Municipality
A Study of Urban Area Plan for Pabna MunicipalityA Study of Urban Area Plan for Pabna Municipality
A Study of Urban Area Plan for Pabna Municipality
 
Top Rated Call Girls In chittoor 📱 {7001035870} VIP Escorts chittoor
Top Rated Call Girls In chittoor 📱 {7001035870} VIP Escorts chittoorTop Rated Call Girls In chittoor 📱 {7001035870} VIP Escorts chittoor
Top Rated Call Girls In chittoor 📱 {7001035870} VIP Escorts chittoor
 
DC MACHINE-Motoring and generation, Armature circuit equation
DC MACHINE-Motoring and generation, Armature circuit equationDC MACHINE-Motoring and generation, Armature circuit equation
DC MACHINE-Motoring and generation, Armature circuit equation
 
Water Industry Process Automation & Control Monthly - April 2024
Water Industry Process Automation & Control Monthly - April 2024Water Industry Process Automation & Control Monthly - April 2024
Water Industry Process Automation & Control Monthly - April 2024
 

HUMAN MACHINE INTERFACE THROUGH ELECTROMYOGRAPHY MINOR PROJECT FULL REPORT

  • 1. i A PROJECT REPORT ON HUMAN MACHINE INTERFACE THROUGH ELECTROMYOGRAPHY Submitted by ARJUN RAM GAUTAM NATH HITESH DEWASI UNDER THE GUIDANCE OF PROF. RITESH SARASHWAT in partial fulfillment for the award of BACHELOR OF TECHNOLOGY IN ELECTRONICS AND COMMUNICATION ENGINEERING FROM RAJASTHAN TECHNICAL UNIVERSITY DEPARTMENT OF ELECTRONICS AND COMMUNICATION ENGINEERING JODHPUR INSTITUTE OF ENGINEERING AND TECHNOLOGY MOGRA, N. H. 62, PALI ROAD,JODHPUR-342802 NOVEMBER-2015 SESSION 2015-16
  • 2. ii JODHPUR INSTITUTE OF ENGINEERING & TECHNOLOGY DEPARTMENT OF ELECTRONICS & COMMUNICATION ENGINEERING CERTIFICATE This is to certify that the following students ARJUN RAM, GAUTAM NATH & HITESH DEWASI have successfully completed the project Titled " HUMAN MACHINE INTERFACE THROUGH ELECTROMYOGRAPHY” towards the partial fulfillment of Bachelor of Technology in Electronics and Communications engineering of the Rajasthan Technical University during academic year 2015 – 2016. …..….………………… ……………………….. Project Associate Guide (Prof. Lakshmi Chaudhary) (Prof. Ritesh Saraswat) INTERNAL EXAMINER EXTERNAL EXAMINER (Signature with Date) (Signature with Date)
  • 3. iii ACKNOWLEDGEMENT At the very outset, I take this opportunity to express my sincere gratitude to all those who helped me in the successful completion of my Project report. We would like to make a number of acknowledgements to those who have helped us to prepare this report. We are highly grateful to Prof. O. P. VYAS, Dean (Engineering), JIET for proving us this opportunity to carry out independent study on this topic. The divine support given by our guide Prof. Ritesh Saraswat (B. Tech) , Prof. K. K. ARORA, HOD (M. Tech) & Prof. (Dr.) HEMANT PUROHIT, HOD (B. Tech) Department of Electronics and Communication Engineering, J.I.E.T, Jodhpur, without them the work would not be possible. NAME ROLL NO ARJUN RAM 12EJIEC705 GAUTAM NATH 12EJIEC714 HITESH DEWASI 12EJIEC720
  • 4. iv TABLE OF CONTENTS CHAPTER PAGE NO. Title Page…………………………………………………………………….i Certificate………………………………….………………………………...ii Acknowledgement…………………………….………………………….…iii List Of figure………………………………………………………………..vi Abstract……………………………………………………………….…….vii Market Survey……………………………………………………………..viii 1. INTRODUCTION 1.1 Project Overview……………………………………….…………...1 1.2 Hardware Specification……………………………….…………….2 1.2.1 EMG portable Device……………………………….…...……..…2 1.2.2 EMG Electrode Type………………………………..…………….2 1.2.3 IC-INA 122 Op-Amp……………………………….……………..3 1.2.3.1 Description……………………………………….……………...4 1.2.3.2 Specification…………………………………………………….6 1.2.3.3 Application……………………………………….……………...6 1.2.4 IC- OPA 2241 Op-amp………………….…………………………7 1.2.4.1 Description……………………………………………………….7 1.2.4.2 Specification……………………………………………………...8 1.2.4.3 Application………………………………………………………..8 1.2.5 Battery………………………………………………………………9 1.2.5.1 Specification…………………………………………..…………..9 1.3 Software Specification………………………………………..……...10 2. STUDY & ANALYSIS 2.1 Need of Study………………….…………………………..………….11 2.2 Signal Recording………………………………………………..……..11 3. DESIGN 3.1 Methodology……………………………………….…………………12 .. 3.2 Signal Processing……………………………………….…….………13
  • 5. v 3.3 Circuit Design…………………………………………...………......15 3.4 PCB Layout…………………………………………..………..……15 3.5 Working……………………………………………….……….……16 4. APPLICATION…………………………………………………………..…18 5.1 ADVANTAGE……………………………………………………………..19 5.2 DISADVANTAGE……………………………………………………..….19 6. FUTURE SCOPE…………………………………………………….……..20 7. CONCLUSION……………………………………………………………..21 8. REFERENCE……………………………………………………….……....22
  • 6. vi LIST OFFIGURE FIGURE NO. FIGURE NAME PAGE NO. CHAPTER 1 1.2.1 EMG Portable Device 2 1.2.2.1 NMES Electrode 3 1.2.2.2 Metallic Disc Electrode 3 1.2.2.3 Nor axon’s gel Electrode 3 1.2.2.4 Use of Electrode 4 1.2.2.5 Fine Wire 4 1.2.3.1 Symbol Of Op-Amp 5 1.2.3.2 IC-INA 122 Op-Amp Pin Configuration 5 1.2.3.3 IC-INA 122 Op-Amp 6 1.2.4.1 IC-OPA 2241Pin Configuration 7 1.2.4.2 IC-OPA 2241 Op-Amp 8 1.2.5.1 Battery-9 Volt 9 1.3.1 Software Processing Analysis 10 1.3.2 EOG Signal Characteristics 10 CHAPTER 2 2.2.1 Electrode Placement 11 CHAPTER 3 3.2.1 System Design 13 3.2.2 Signal Processing 13 3.3.1 CIRCUIT DIAGRAM 15 3.4.1 PCB LAYOUT 15 3.4.2 Single Side PCB 16 3.5.1 EMG Signal 17 3.5.2 Electrode Placement 17
  • 7. vii ABSTRACT Electromyography (EMG) signals can be used for clinical/biomedical applications, Evolvable Hardware Chip (EHW) development, and modern human computer interaction. EMG signals acquired from muscles require advanced methods for detection, decomposition, processing, and classification. The purpose of this paper is to illustrate the various methodologies and algorithms for EMG signal analysis to provide efficient and effective ways of understanding the signal and its nature. We further point up some of the hardware implementations using EMG focusing on applications related to prosthetic hand control, grasp recognition, and human computer interaction. A comparison study is also given to show performance of various EMG signal analysis methods. This paper provides researchers a good understanding of EMG signal and its analysis procedures. This knowledge will help them develop more powerful, flexible, and efficient applications.
  • 8. viii MARKET SURVEY SR.NO. COMPONENT NAME (MAJOR & MINOR) SPECIFICATION PRICE 1 IC 1 INA 122 Op-Amp 160 2 IC 2 OPA 2241 Op-Amp 160 3 Resistor R1 (100 K ) 1 R2, R3 (10 K ) 1 R4 (1 K ) 1 4 Capacitor 1 uF,25 volt electrolytic 5 5 Battery 9 Volt 20 6 Ultrasound Gel ------- 25 7 Switch On/Off 10 8 Connector 3/2 Pin Connector 130 9 Electrode ECG Metallic/Disposal Electrode 700
  • 9. 1 CHAPTER 1 INTRODUCTION 1.1 PROJECT OVERVIEW: Electromyography (EMG) is defined as the study of the muscular function through the Analysis of the generated electric signals during muscular contractions. The potential difference obtained in the fibers can be registered in the surface of the human body through surface electrodes due to the biological tissues conducting properties. Our project studies the muscular activity as an input In order to control applications. A large set of target muscles are available so we can interact widely with the computer. The main goal of the project is to provide tetraplegia individuals the capability to control a portable device (especially to be able to write and send SMS). In order to accomplish this task we monitories’ muscle activity through an Electromyography The recurrent and increasing electromyography study in medicine related areas led to a great Scientific investment improve the myographic signal acquisition and analysis process. These advances culminate with the possibility to use portable electromyography devices that Communicate via wireless with a processing system. Portability makes it possible for any individual the transport and use of an EMG device with great social acceptance (Costanzia et al., 2004). EMG devices portability and reduced size easily conducted to its use in HCI with work carried through in the area of Accessibility, Robotics, Mobile Computation and Recognition of Gestures, among others. (Roy et al, 1994) present a gesture-based person Portable device, process the digital signal and emulate certain events accordingly to the Features detected. Being able to detect and to evaluate muscular activity in an individual gives us the possibility to associate it with determined interface commands, thus having the myographic signal as input. This kind of interaction can also be useful to full capable individuals in a hands-busy situation, such as in a presentation or in a mobility context. Machine interface for people with serious motor limitations due to cerebral paralysis. This work, based on gestural recognition with biomechanic and bioelectric sensors, present many motivating results being capable to differentiate gestures through the use of neural networks. In the same scope, (Barreto et al., 1999) introduce a system that tries to offer the users with serious motor limitations the possibility to use the traditional interfaces to
  • 10. 2 Point and select. This system associates face movements to mouse control, being sufficiently similar to the system ”Tongue Point” (Salem and Zhai, 1997) but using myographic signals. It is still in the accessibility context that (Erikssonet al., 1998) lean over prosthesis control. As discussed in the introduction, a person’s brain wave -*patterns and muscle stimulation can be measured and recorded using almost identical measurement techniques. With accurate results, researches will soon be able to show a detailed direct Relation between mental thought and physical motion, improve communications with lacking motor Skills, and much more. But what are these measurement procedures and how are they carried out? 1.2 HARDWARE SPECIFICAION: 1.2.1 EMG Portable Device: Our electromyography device collects samples at a 1000Hz sampling rate in 5 independent channels. It has a 110dB CMRR amplifier and a band pass filter between 25 and 500 Hz with gain 1000. It is a relatively small device (14cm * 8cm * 4cm) that can be carried in a belt or pocket. It is a portable device which communicates by a Bluetooth interface within a 100 meters range. To col- lect the signals we use surface differential electrodes, with 1.5 cm radius (Gam boa et al., 2004) Figure 1.2.1 EMG Portable Device 1.2.2 EMG ELECTRODE TYPES: Most major limb and trunk muscle activity can be measured using surface electrode techniques. For deeper, smaller, or overlaid muscles fine wire electrodes need to be used to acquire intramuscular activities. For surface electrodes, simple platinum or silver disc electrodes, pre-gelled Ag-AgCl electrodes, and wet-gel electrodes are commonly used. The disc electrodes are reusable while the gel electrodes are single use. Distinction exists between electrodes used for SEMG and those used for NMES and ETS. Whenever an electrical stimulation is applied, the electrodes used must be properly designed to deliver
  • 11. 3 Such electrical stimulations otherwise the power density generated at the skin contact can result in patient injury. Also, for the evaluation and treatment of incontinence, special vaginal and anal probes are used to measure the pelvic floor muscle activities. Fig 1.2.2.1 - NMES electrodes: Fig 1.2.2.2:- Metallic disc electrodes Fig 1.2.2.3 :- Noraxon’s gel electrodes: pre-gelled AgCl (1, 2) and wet- gels (3, 4)
  • 12. 4 Fig 1.2.2.4:-Use of electrode Fig 1.2.2.5:-Fine wire electrode For all electrode types, additional measures can be taken to affix the electrode cabling to the patient body to minimize movement artifacts. Regular adhesive tape, hook and loop fasteners, and elastic straps are commonly used to secure cabling onto the body, but never the electrodes as this will affect the readings when intramuscular EMG is required to look into the electrical activity of deeper or overlaid muscles, thin and flexible fine wire electrodes are used. The fine wire electrode is inserted into the muscle site of interest. The needle or steel cannula is removed, and the electrode wires are connected to the steel spring adapters to minimize movement artifacts. 1.2.3 IC-INA 122 OPAMP: 1.2.3.1 Description: The INA122 is a precision instrumentation amplifier for accurate, low noise differential signal acquisition. Its two-op-amp design provides excellent performance with very low quiescent current, and is ideal for portable instrumentation and data acquisition systems. The INA122 can be operated with single power supplies from 2.2V to 36V and quiescent current is a mere 60mA. It can also be operated from dual supplies. By utilizing an input level-shift network, input commonmode range extends to 0.1V below negative rail (single supply ground). A single external resistor sets gain from 5V/V to 10000V/V. Laser trimming provides very low offset
  • 13. 5 Voltage (250mV max), offset voltage drift (3mV/°C max) and excellent common-mode rejection. Package options include 8-pin plastic DIP and SO-8 surface-mount packages. Both are specified for the –40°C to +85°C extended industrial temperature range. Fig 1.2.3.1:- Symbol of Op-amp Fig 1.2.3.2:- IC-INA 122 Op-amp pin configuration
  • 14. 6 Fig1.2.3.3:-IC-INA 122 Op-amp 1.2.3.2 SPECIFICATION:  LOW QUIESCENT CURRENT: 60mA  WIDE POWER SUPPLY RANGE  Single Supply: 2.2V to 36V  Dual Supply: –0.9/+1.3V to ±18V  COMMON-MODE RANGE TO (V–)–0.1V  RAIL-TO-RAIL OUTPUT SWING  LOW OFFSET VOLTAGE: 250mV max  LOW OFFSET DRIFT: 3mV/°C max  LOW INPUT BIAS CURRENT: 25nA max  8-PIN DIP AND SO-8 SURFACE-MOUNT 1.2.3.3 APPLICATIONS:  PORTABLE, BATTERY OPERATED SYSTEMS  INDUSTRIAL SENSOR AMPLIFIER:  Bridge, RTD, Thermocouple  PHYSIOLOGICAL AMPLIFIER:  USE IN ECG, EEG, EMG  MULTI-CHANNEL DATA ACQUISITION
  • 15. 7 1.2.4 IC-OPA 2241 OPAMP: 1.2.4.1 DESCRIPTION: The OPA241 series and OPA251 series are specifically designed for battery powered, Portable applications. In addition to very low power consumption (25mA), these amplifiers feature low offset voltage, rail-to-rail output swing, high common-mode rejection, and high open-loop gain. The OPA241 series is optimized for operation at low power supply voltage while the OPA251 series is optimized for high power supplies. Both can operate from either single (+2.7V to +36V) or dual supplies (±1.35V to ±18V). The input common-mode voltage range extends 200mV below The negative supply—ideal for single-supply applications. They are unity-gain stable and can drive large capacitive loads. Special design considerations assure that these products are easy to use. High performance is maintained as the amplifiers swing to their specified limits. Because the initial Offset voltage (±250mV max) is so low, user adjustment is usually not required. However, external trim pins are provided for special applications (single versions only). Fig 1.2.4.1:-Pin configuration of OPA2241 Op-amp
  • 16. 8 Fig 1.2.4.2:-IC-OPA 2241 OP-AMP The OPA241 and OPA251 (single versions) are available in standard 8-pin DIP and SO- 8 surface-mount packages. The OPA2241 and OPA2251 (dual versions) come in 8-pin DIP and SO-8 surface-mount packages. The OPA4241 and OPA4251 (quad versions) are available in 14-pin DIP and SO-14 surface-mount packages. All are fully specified from –40°C to +85°C and operate from –55°C to +125°C. 1.2.4.2 SPECIFICATION:  Micro POWER: IQ = 25mA  Single Supply Voltage  Rail-to-Rail Output within 50mV  Low Offset Voltage: 250uV max  High Common-Mode Rejection: 124dB  High Open-Loop Gain: 128dB  Input Bias Current: -4nA  Input Offset Current: 0.1nA  Input Voltage Noise, f = 0.1Hz to 10Hz: 1uVp-p  Common-Mode Voltage Range: -0.2V to (V+)-0.8V 1.2.4.3 APPLICATIONS:  Battery Operated Instruments  Portable Devices  Use in Medical Instruments  Use in Test Equipment
  • 17. 9 1.2.5 BATTERY: Fig 1.2.5.1- 9 volt battery 1.2.5.1 SPECIFICATION:  Nominal Voltage- 9 volt  Impedance - 1,700 m-ohm @ 1 kHz  Typical weight - 45 g (1.6 oz)  Typical volume - 22.8 cm3 (1.4 in3)  Terminals- Miniature snap  Storage temperature range - 5ºC to 30ºC (41ºF to 86ºF)  Operating temperature range - 20ºC to 54ºC (-4ºF to 130ºF)  Designation - ANSI: 1604A IEC: 6LR6
  • 18. 10 10 1.3 SOFTWARE SPECIFICATION: The software application analyzes the amplitude of the incoming signals, as the criteria of an occurred event (opening/closing of the hand) are the threshold changes of the first derivative. When this happens, an In order a processing by a computer to be enabled, the analog data needs to be converted in a digital form. А multifunctional USB device of National Instruments− NI USB-6009 (Fig. 6-3), has been used. The EMG signal is fed to one of the analog inputs. The visualization and the data processing are done through software Fig. 1.3.1. Software for processing, analysis and gripper control Similarly, the amplified signal is fed to an analog input of NI USB-6009 for conversion and then the data are analyzed by Lab View software. As can be seen in Fig. 1.3.2 -. Fragment of software for processing and analysis of EOG: EOG signal characteristic (above); animation showing the actual position of the eyes (below)
  • 19. 11 11 CHAPTER-2 STUDY & ANALYSIS 2.1 NEED OF STUDY Despite of the scope, all the projects refereed in- tend to present EMG as an input interface. In this article we present our results and present user studies to go further and validate electromyography de- vices as daily wearable interfaces. Our prototype ac- complishes the control of various computer Applications and introduces a synergy between applications that ease the text-entry task. In the next section we present our approach. The other sections are focused in the user evaluations, results and discussion. In the last section we present the conclusions taken by the user evaluations along with the work still to be done. 2.2 SIGNAL RECORDING: In order to get useful information concerning the muscular activity it is necessary to carefully analyze some aspects, from technical details at the electrode placement in the surface of the human body to the points where this placement must be done. Several aspects influence the signal quality: skin preparation, electrodes placement position, electrodes fixation, electrodes distance and outside interferences (De Luca, 1997).We have discarded all the skin preparation techniques since we don’t think they are appropriate to a user interface. Besides, after several tests we observed good signal quality with small interference. However, to reinforce the surface electrodes adherence we created an elastic band for the neck and two elastic bands for the forearm. We used the 2cm distance between electrodes which guarantees a solution of commitment (Figure 2), collecting the signal of a significant portion of the muscle and restricting, simultaneously, the undesired signals to insignificant values (De Luca, 1997). Figure 2.2.1: Electrodes placement
  • 20. 12 12 CHAPTER 3 DESIGN 3.1 METHODOLOGY We conducted several experiments to assess the us- ability of myographic activity as as interaction modal- ity. For that purpose, besides the experiments to vali- date the interaction speed and accuracy, we focused our attention in the interface robustness as a daily wearable interface. a) Clicking Start Button, where a timer is activated; b) Moving the cursor towards the Stop button, with any trajectory; c) Clicking Stop Button, and the time is presented to the user and saved. The Start Button dimensions are always 8, 5 x 8,5mm but there are four Stop Button dimensions (8.5 x 8.5mm; 12.5 x 12.5mm; 17 x 17mm; 22 x 22mm). We made 80 evaluations, 20 of each for every Stop Button size. The Start Button changed between the four corners. The users were equipped with two pairs of electrodes in each forearm (four directions) and another pair near one eye to detect blinking
  • 21. 13 13 3.2 SIGNAL PROCESSING: Figure 3.2.1: System Design The pre-processing is composed by some basic procedures that prepare the signal to be smoothed. The signal received from the electromyography device has Figure 3.2.2: Signal Processing
  • 22. 14 14 As mentioned before, the useful frequency range is between 0 Hz and 500 Hz. So filtering the raw signal is recommended to limit the signal’s frequency range to the desired range. Van Boxtel in [vB08] found that a band-pass frequency range of 20 Hz to 500 Hz appeared to be adequate because there was a negligible contribution of higher frequency components to the EMG signal. In [CJDLR10] De Luca et al. are recommending to set the low-pass filter corner frequency to 400- 450 Hz, where the high end of the SEMG frequency spectrum is expected. Various recommendations for the high-pass filter corner frequency can be found in literature. All the recommendations are between 5 Hz and 20 Hz. SENIAM recommends to set the high-pass filter corner frequency to 10 - 20Hz For several decades it has been commonly accepted that the preferred manner for processing the EMG signal after filtering was to calculate the integrated rectified signal. This was done by full-wave rectifying the EMG signal, integrating the signal over a specified interval of time and subsequently forming a time series of the integrated values. Full- wave rectification means the conversion of the input waveform to one of constant polarity (positive or negative) at its output. This approach of rectifying and integrating became widespread since it is possible to make these calculations accurately and inexpensively with the limited electronics technology of earlier decades. Equation (2.2) shows how the calculation of the integrated rectified signal is
  • 23. 15 15 3.3 CIRCUIT DIAGRAM: Fig 3.3.1:-Circuit diagram of Human Machine Interface through Electromyography 3.4 PCB LAYOUT Fig. 3.4.1: Component layout for the PCB
  • 24. 16 16 Fig. 3.4.2: An actual-size, single-side PCB for HMI through EMG 3.5 WORKING The circuit diagram of HMI through EMG is shown in Fig. 3. Starting from the left, two electrodes attached to a muscle are connected to a single-supply instrumentation amplifier INA122 (IC1), which amplifies the voltage difference between the two electrodes, rejecting any signal that is common to both—thereby removing much of the noise and 50Hz AC EMI. Resistor R1 determines the gain of the output of IC1. It is difficult to deal with the bi-polar nature of the bio-signals. To overcome this problem, we use virtual-ground topology or split-rail topology, which splits the main power rail into two rails—one having Vcc and the other with half of Vcc (virtual ground). The created virtual ground acts as the pseudo-zero voltage and thus makes the output to swing between 0 and Vcc with virtual ground as zero volts, which makes the entire portion of the EMG wave available and also in the positive range only, thus making this topology ideal for interfacing with digital systems or microcontrollers. IC1 is specifically designed for single-supply operations, for which it includes voltage translators and overvoltage protection. The electrodes are directly attached to the muscle. Prior to attaching the electrodes, clean the patient’s skin with alcohol for removing dirt and apply an ultrasound gel. Two electrodes are attached over the muscle of interest and the third one (reference) is connected
  • 25. 17 17 to an area preferably in the joints where there are less muscles. The reference electrode should only be connected at pin 3 of CON1. It is vital as it provides the common-mode signal. The reference is connected to the virtual ground and pin 5 (Vref) of IC1, so care must be taken to isolate the patient from ground. The patient must not touch any grounded metal, which can cause drainage of common-mode voltage and thus raise the amplitude of the output and inject a lot of noise. The output from instrumentation amplifier IC1 is fed to a non-inverting amplifier built around OPA2241 (IC2) via capacitor C1, which removes the DC offset from the electrodes. The amplified output signal from IC2 is sent to the PC oscilloscope via an audio jack to get the display of the waveform. Fig.3.5.1-EMG Signal on the Pc based oscilloscope, Fig 3.5.2 :-Electrode Placement
  • 26. 18 18 CHAPTER 4 APPLICATION 1. Skin placement. 2. Avoid movement of electrodes by using straps or tape to firmly secure electrode I place. 3. Avoid bending of leads, place leads pointing in the direction that you want the wire to Continue in. (e.g., for electrodes placed on an extremity, have the lead pointing towards The proximal end of the extremity so that the wire will not have to be bent in order to go In the proximal direction.) 4. Avoid any stress on the wires by making sure that the wires are loose underneath the Tape or wrap that is holding them in place. Be sure to check when the wires cross the Joint that once the joint is fully extended the wires are not drawn taunt. 5. Avoid placing electrodes over scars. 6. Measured potential. 7. Measuring skeletal muscle electrical output during physical activity 8. Sports medicine 9. EMG signals can be used for variety of applications like clinical/biomedical 10. EMG can be used to sense isometric muscular activity 11. To measure the force of the isometric muscle contraction, a surface EMG was used 12. The idea of controlling machines with levers and knobs. Instead, they plan to have machines respond directly to human gestures.
  • 27. 19 19 CHAPTER 5 5.1 ADVANTAGE  Extremely sensitive  Record single muscle activity  Access to deep musculature  Little cross-talk concern  Surface EMG Recording Provide a safe.  Easy and noninvasive method 5.2DISADVANTAGE  Extremely sensitive  Requires medical personnel, certification  Repositioning nearly impossible  Detection area may not be representative of entire muscle
  • 28. 20 20 CHAPTER 6 FUTURE SCOPE It is intended to develop software environment for computer’s mouse control and cursor movement, done by eye movements. Such a development could be useful for people with disabilities, allowing them access to a computer. The application can easily be extended to allow control of various electromechanical devices (wheelchairs). At the date of submission of the paper a project was launched for realization of artificial, five-finger hand which will be controlled by registered EMG potentials. In the near future we will see higher function prosthetics, brain computer interfaces with more control, voice recognition and camera gesture recognition being used more. Although not quite the death of the everyday mouse and keyboard, we will dentally start to see new types of technology integrated into our everyday lives. Portable devices are becoming smaller and more complex, so we should start seeing growth in wearable interfaces. Robots, and the way we interact with them is already beginning to change, we are in the computer era, but soon we will be in the robotic era. Nano technology has provided a new wave of advancements, but these have yet to be fully utilized in HMI, Nano technology has an important future role to play. Nano machines and super batteries haven't fully materialized, so we have something to look forward to. There is also the potential of Quantum Computing which will unleash an entirely new level of processor, with amazing speeds. HMI technology is impressive now, but in the future there will be nothing like it. It won't matter who you are, what language you speak, or what disability you have, the variety of technology will cater for everyone. This document has provided an overview of what HMI , and has shown you a glimpse of what the future might hold. One thing that is certain is that technologies will begin to converge, devices will combine functionality, new levels of sensor fusions will be created, and all this for one purpose, to enhance our Human Machine Interaction. The technology involved in HMI
  • 29. 21 21 CHAPTER 7 CONCLUSION The EMG/EEG-based Human–Computer Interaction system presented represents a potential alternative for the communication of individuals with severe motor disabilities and their computers. Because the system commands cursor movements on the basis of detection and classification of EMG signals, its operation is relatively simple for the user. Use of the interface only requires the voluntary contraction of a set of cranial muscles, requiring little training on the part of the subject. The operation of the system is possible due to the difference in the spectral composition of EMG signals generated by contraction of different cranial muscles. Thus, the novel classification approach allows the on-line separation of EMG signals caused by the contraction of different muscles, based on the real-time estimation of their power spectra. In our evaluation of the interface, six experimental subjects were able to drive the computer cursor from the Screen corners to the center and perform a click at each end of that trajectory in an average of 16 seconds. This level of performance achieved by untrained subjects reveals that this interface can be employed for such applications as web browsing and appliance control through appropriate hardware/software setups. In comparison with other unassisted interfaces for users with disabilities, the EMG/EEG interface proposed has the potential to be more affordable and portable then others, such as eye-gaze tracking devices
  • 30. 22 22 REFERENCES 1. http://www.kevinwarwick.com/ 2. Basmajian JV, et al. Computers in Electromyography. Butterworths, 1975 3. Shavi R, Green N. Ensemble averaging of locomotors electromyography patterns using interpolation. Med & Biol Eng & Comput, 21: 573-578, 1983. 4. De Luca. C.J. (1997) The Use of Surface Electromyography in Biomechanics. Journal of Applied Biomechanics, Volume 13, Pages 135-163, 1997 5. www.datasheets4u.com 6. http://www.electronicsforyou.com 7. Kuiken, A. & Lipschutz, R. (2008) A strategy for identifying locomotion modes using surface electromyography 8. https://www.grasstelefactor.com/products/clinsystems/cmeeg1.html 9. http://www.futurehealth.org/a-2.htm 10. http://www.biosemi.com/publications/artikel4.htm