IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308
_______________________________________________________________________________________
Volume: 04 Issue: 03 | Mar-2015, Available @ http://www.ijret.org 548
NUMERICAL AND EXPERIMENTAL STUDY OF A SOLAR WATER
HEATER FOR ENHANCEMENT IN THERMAL PERFORMANCE
K. Vasudeva Karanth1
, Madhwesh N2
, Shiva Kumar3
, Manjunath M.S4
1
Corresponding Author, Department of Mechanical & Mfg. Engineering, M. I. T., Manipal, Karnataka, India
2
Department of Mechanical & Mfg. Engineering, Manipal Institute of Technology, Manipal, Karnataka, India
3
Department of Mechanical & Mfg. Engineering, Manipal Institute of Technology, Manipal, Karnataka, India
4
Department of Mechanical & Mfg. Engineering, Manipal Institute of Technology, Manipal, Karnataka, India
Abstract
Largest commercial application amongst the various solar collectors is the solar flat plate collectors mainly due to its simple
design as well as low maintenance cost. Numerical analysis of the solar water heater which involves conduction and convection
due to radiation heat transfer using Computational Fluid Dynamics (CFD) as a tool has not been the focus of study so far. It is
generally understood that sinusoidal flow passage tends to increase turbulence which in turn increases convective heat transfer.
The advantage of using straight absorber tube over sinusoidal absorber tube on the thermal behavior of the solar water heater
needs to be explored as a design prescription. In the study presented in this paper it is noted from the experimental and numerical
analysis that the straight tube configuration has better performance than that of sinusoidal pipe configuration.
Keywords: Sinusoidal tube, Solar water heater, Convective heat transfer, Computational fluid dynamics.
--------------------------------------------------------------------***----------------------------------------------------------------------
1. INTRODUCTION
Solar flat plate collectors even though produce lower
temperature rise, they are simpler in design and have lower
maintenance cost. Solar collector is a complex heat
exchanger that transfers radiation heat from the sun to the
working fluid. Kumar & Rosen [2] explored the
performance of an integrated solar water heater using
corrugated absorber plate. The absorber plate surface is
considered to be corrugated with small indentation depths.
They results revealed that solar water heater had higher
operating temperature for longer time as compared to the
flat absorber plate.
Prasad et al [3] conducted an experimental study on a flat
plate water heater with sun tracking mechanism. The found
that the thermal efficiency increased by about 21%.Varol
and Oztop [4] numerically examined the fluid flow and heat
transfer in a collector with wavy absorber plate. The results
showed that higher Rayleigh number and aspect ratio
increases the heat transfer while increasing the wavelength
decreases the heat transfer. Karim and Hawlader [5] carried
out an experimental analysis on V-groove air heating system
under the operating conditions of Singapore. They found
that the V-corrugations provided improved thermal
efficiency as compared to a flat plate collector.
Varol and Oztop [6] carried out a CFD analysis of natural
convection heat transfer inside the inclined wavy solar
collectors and flat-plate solar collectors. They found that the
fluid flow and heat transfer are affected by the geometry of
enclosure and augments the heat transfer as compared to the
flat enclosure. Akpinar and Kocyigit [7] conducted an
experimental analysis on a novel flat plate solar air heater
fitted with several obstacles to provide turbulence in the
fluid flow. They found that the presence of obstacles
significantly increases the heat transfer. Gertzos and Caouris
[8] conducted an experimental and numerical analysis on an
integrated collector storage solar device with recirculation
and established a validated three-dimensional CFD model.
Wang et al. [9] conducted a numerical simulation on
transpired solar air collector and found that the collector has
significant advantages in the ventilation preheating area and
also proves that CFD tools have their own advantages in the
solar air collector research area. Selmi et al. [10] conducted
a validated CFD model for flat plate solar water heater. Ho
et al. [11] carried out an experimental and theoretical
analysis of recyclic flat-plate solar water heater equipped
with rectangle conduits. They found that the collector
efficiency increases with increasing flow conduit aspect
ratio and recycle ratio. Kumar and Prasad [12] found that
use of twisted tape inserts inside the water tube increases the
efficiency by 18-70% with a pressure drop of 87-132% as
compared to ordinary collectors.
It is observed from the literature review of solar water
heaters that numerical analysis of the solar water heater
which involves conduction and convection due to radiation
heat on the sine wave absorber tube using CFD has not been
the focus of study so far. It is generally understood that
sinusoidal flow passage tends to increase turbulence which
in turn increases convective heat transfer. The advantage of
using straight absorber tube over sinusoidal absorber tube on
the performance of the solar water heater needs to be
explored as a design prescription. Hence in this study a CFD
analysis is carried out to explore the efficacy of sine wave
absorber tube over straight absorber tube
IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308
_______________________________________________________________________________________
Volume: 04 Issue: 03 | Mar-2015, Available @ http://www.ijret.org 549
2. NUMERICAL ANALYSIS
2.1 Geometry Description and Assumptions
Fig.1. Straight tube configuration of solar water heater
Fig.2. Sinewave configuration of solar water heater
The flow domain consists of an absorber plate of 1 .2 m
length, 195 mm wide and 0.5 mm thickness. An absorber
tube of 12.5 mm diameter and 0.65 mm thickness is attached
below the absorber plate. The absorber plate and the
absorber tube are insulated with glass wool of 25 mm
thickness. The water tube is attached to the absorber plate by
placing it centrally with a small angle of lap. The first
configuration adopted in the study is a straight absorber tube
as shown in figure 1. The second configuration is a tube of
sine wave geometry having a wave length of 0.6 m and
amplitude of 30 mm as shown in figure 2. The assumptions
made in the analysis are, a) Water is a continuous medium
and incompressible. b) The flow is steady and possesses
laminar flow characteristics, at lower velocity and turbulent
characteristics at higher velocity. C) The thermal-physical
properties of the absorber plate and the absorber tube are
constant with respect to the operating temperature.
2.2 Numerical Method
Numerical simulation is carried out with steady state
implicit pressure based solver using the Fluent 14.5 code
[1]. The governing partial differential equations for mass
and momentum are solved for the steady state flows. The
pressure-velocity coupling is carried out using the SIMPLE
algorithm [1]. Discretization is done using the second order
upwind scheme.
2.3 Mean Flow Equations
All the equations are presented in Cartesian tensor notation.
Continuity:
( ) 0 (1)i
i
U
x




Momentum equation
( ) (2)
ji
i j i j
j i j j i
UUP
U U u u
x x x x x
  
    
             
Energy equation
( ) (3)
Pr
i i
j j j
T
U T u t
x x x

 
   
  
    
2.4 Numerical Scheme
Fig.3 Localized cross sectional view of the meshed
computational domain
The three dimensional computational domain is modeled
using hex mesh and a localized view of the mesh is shown
in Figure 3. The complete domain consists of 1.5 million
elements which include the water, water tube absorber plate
and insulating material. The grid independence test was
performed to obtain an optimal mesh for the computational
domain. It was found that further refinement of mesh size
did not change the result by more than 1 % which is taken
here as the optimal mesh quality for computation.
Steady state simulation is carried out to establish the flow
and thermal characteristics of the solar water heater models
with straight and sinewave tube. Convergence was
considered when all the scaled residuals fell below 10-5
in
the computational domain.
2.5 Boundary Conditions and Operating
Parameters
A ‘mass flow inlet’ boundary condition is specified at the
inlet and an ‘outflow’ condition is specified at the outlet for
the water continuum. The mass flow rate for the numerical
study is as obtained from the experimental study. Wall
boundary conditions were used to bound fluid and solid
IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308
_______________________________________________________________________________________
Volume: 04 Issue: 03 | Mar-2015, Available @ http://www.ijret.org 550
regions. At the wall, no-slip and impermeability conditions
are applied. The interface between the water and the
absorber tube is defined as wall with coupled condition to
effect conjugate heat transfer from absorber tube to the
water. A standard k  model is adopted in the analysis to
take into account the turbulence that might occur in the flow
domain.
In order to numerically establish the effectiveness of the two
configurations of water heater adopted in the analysis, the
numerical models are modeled with approximately the same
number of elements and identical boundary conditions are
applied. The performance parameters adopted for
comparison of the two configurations are i) the Nusselt
number (Nu) and ii) the convective heat transfer coefficient
(h). The temperature coefficient CT is calculated using
Eq.(4) where, T0 is the water inlet temperature. Length ratio
for the flow path is taken as Lr = l/L, where L = 1.2 m.
0
0
T
T T
C
T


(4)
3. EXPERIMENTAL SETUP
The solar water heater structure is fabricated using half inch
thick plywood material and is 1.2 m long, 0.22 m wide and
0.05 m in height. The upper surface is made up of a 0.5 mm
thick copper plate which is the absorber plate exposed to
solar radiation. The absorber plate is painted black for
absorbing the heat due to solar radiation. RTD (Resistance
Temperature Detectors) type thermocouples are at the inlet,
outlet and the absorber plate for measuring the water
temperature and the absorber plate temperature. The heat
flux that is incident on the absorber plate due to solar
irradiation is measured using a Pyranometer. The
experimentation was carried out between 1130 a.m. to 1.30
p.m. when the average heat flux as recorded by the
pyranometer was noted to be 810W/m2
. The experiments
were carried out for 4 different mass flow rates of 20ml/min,
63 ml/min, 198ml/min and 360 ml/min.
4. RESULTS AND DISCUSSION
The numerical, analysis is carried out after the experimental
study of the two collectors is conducted and the mass flow
rates adopted in the experimental study are taken as the
input for the numerical analysis.
0 50 100 150 200 250 300 350
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
Temperaturerisecoefficient(CT
)
Mass flow rate (ml)
Numerical value
Experimental value
Fig. 5 Absorber fluid temperature rise coefficient
corresponding to various mass flow rates for sine wave tube
configuration
Fig. 4 shows the validation plot for the temperature rise
coefficients of the absorber fluid corresponding to the four
mass flow rates for straight tube configuration. It can be
observed from this graph that at lower mass flow rates the
experimental and numerical values of the absorber fluid
temperature coefficients vary with a large difference.
However at higher mass flow rates, the temperature
coefficients for experimental and numerical analysis come
closer with a matching trend line. The same trend is
observed for sine wave configuration as can be seen in Fig.
5. The large gap between the numerical and experimental
results at lower mass flow rates can be attributed to the heat
loss that takes place across the boundaries which are not
accounted in the numerical analysis which assumes ideal
insulating conditions.
0 50 100 150 200 250 300 350
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
Temperaturerisecoefficient(CT
)
Mass flow rate (ml)
Numerical value
Experimental value
Fig. 4 Absorber fluid temperature rise coefficient
corresponding to various mass flow rates for straight tube
configuration
IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308
_______________________________________________________________________________________
Volume: 04 Issue: 03 | Mar-2015, Available @ http://www.ijret.org 551
0.0 0.2 0.4 0.6 0.8 1.0
0.00
0.05
0.10
0.15
0.20
0.25
0.30
0.35
0.40
Absorberfluidtemperaturerisecoefficient(CT
)
Length ratio (Lr
)
360 ml/min
198 ml/min
63 ml/min
20 ml/min
Fig. 6 Absorber fluid temperature rise coefficient along the
flow length of the tube for straight tube configuration
The simulation is carried out at 4 different mass flow rates
and fig 6 shows the plot for temperature rise coefficient
along the flow length of the absorber tube. From this plot it
is seen that, as the absorber plate is uniformly heated
corresponding to various mass flow rates, the fluid in the
absorber tube gets differentially heated with significant
temperature gradient for lower mass flow rate followed by a
smaller temperature gradient for higher mass flow rates. The
numerical analysis is carried out so as to meet the
convergence criteria and the two configurations are
compared in terms of its thermal performance. The
numerical results for the two configurations are presented in
terms of the Nusselt number (Nu) and the convective heat
transfer coefficient (h) as shown in figures 7 and 8.
It can be observed from the bar diagrams of figure 7 that the
Nusselt number for configuration with straight absorber tube
is higher than that of the sine wave tube configuration for
the given mass flow rate and heat flux on the absorber plate.
This can be attributed to the fact that the fluid in the sine
wave tube has to traverse a larger distance compared to that
of straight tube configuration for the given mass flow rate
and hence reducing the speed of the flow. This leads to a
lower convective heat transfer that is taking place to the
fluid (fig 8.) and hence reducing the Nusselt number.
82.227
151.035
220.142
246.321
81.590
149.811
218.661
244.085
0
50
100
150
200
250
360 ml/min198ml/min63 ml/min20 ml/min
Nusseltnumber(Nu)
Mass flow rate (ml/min)
Straight tube configuration
Sinewave tube configuration
Fig.7. Bar charts of Nusselt number for the two
configurations.
54.724
97.697
139.604
155.19
54.288
96.880
138.536
153.769
0
25
50
75
100
125
150
175
360 ml/min198ml/min63 ml/min20 ml/min
Convectiveheattransfer
coefficient(w/m2
k)
Mass flow rate (ml/min)
Straight tube configuration
Sinewave tube configuration
Fig.8. Bar charts of convective heat transfer coefficients for
the two configurations.
Fig.9 (a) and Fig.9(b) show temperature contour plots of the
absorber plate for sine wave and straight tube configurations
at a lower mass flow rate of 20 ml/min. This is in
comparison with the temperature contour plot for the same
configuration at higher mass flow rate of 360 ml/min as
shown in figures 10a and10b.
It can be noted from these plots that the heat transfer from
the absorber plate to the absorber tube is uniform in case of
straight tube configuration whereas for sinewave
configuration the heat transfer is more near the absorber
tube and hence a non-uniform distribution of temperature is
observed for the absorber plate. This non uniform heat
transfer that takes place from absorber plate to the absorber
tube can also be attributed to the lower Nusselt number and
convective heat transfer for the sinewave tube configuration.
IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308
_______________________________________________________________________________________
Volume: 04 Issue: 03 | Mar-2015, Available @ http://www.ijret.org 552
Fig.9(a). Absorber plate temperature contour plot for
sinusoidal tube configuration at 20ml/min
Fig.9(b). Absorber plate temperature contour plot for
straight tube configuration at 20ml/min
Fig.10(a). Absorber plate temperature contour plot for
sinusoidal tube configuration at a mass flow rate of 360
ml/min
Fig.10(b). Absorber plate temperature contour plot for
straight tube configuration at 360 ml/min
5. CONCLUSION
Numerical study helps in understanding the complex heat
transfer phenomena that takes place in a solar water heater
and helps in quantifying the thermal performance which is
otherwise not possible through experimentation due to the
small difference in the temperatures outputs for the two
comparable configurations. The following conclusions can
be drawn from the numerical study.
 The Nusselt number for the straight tube
configuration is higher than that of sine wave tube
configurations of solar water heater for the given
identical boundary conditions.
 The convective heat transfer coefficient is higher
for straight tube configuration for all the mass flow
rates compared to sine wave configuration.
 Non uniform heating of the absorber plate takes
place for sine wave configuration.
Hence as a design prescription, it can be perceived that the
straight absorber tube configuration has a better heat transfer
capability compared to sine wave absorber tube
configuration.
ACKNOWLEDGEMENTS
The computational facilities were provided by the
Department of Mechanical and Manufacturing Engineering,
Manipal Institute of Technology, Manipal, India which is
appreciatively acknowledged.
NOMENCLATURE
T Temperature
CT Temperature rise coefficient
L Length of the collector
Lr Non-dimensional collector length (x/L)
U Velocity
ρ Density
µ Viscosity
Pr Prandtl Number
Nu Nusselt number
IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308
_______________________________________________________________________________________
Volume: 04 Issue: 03 | Mar-2015, Available @ http://www.ijret.org 553
REFERENCES
[1]. ANSYS Fluent 14.5 User’s manual, Ansys Inc. (2013)
[2]. Kumar, A. Prasad, B.N., “Investigation of twisted tape
inserted solar water heaters-heat transfer, friction factor and
thermal performance results” Journal of Renewable Energy,
Volume 19, pp. 379-398.. 2000.
[3]. Prasad, P.R., Byregowda, H.V., and Gangavati, P.B.,
“Experiment Analysis of Flat Plate Collector and
Comparison of Performance with Tracking Collecto”,.
European Journal of Scientific Research, 40(1), pp. 144 -
155, 2010.
[4]. Varol, Y. & Oztop, H.F., “Buoyancy induced heat
transfer and fluid flow inside a tilted wavy solar collector.
Building and Environment, Volume 42, pp. 2062-2071,
2007.
[5]. Karim, A. Hawlader, M.N.A., “Performance evaluation
of a v-groove solar air collector for drying applications”,
Applied Thermal Engineering, Volume 26, pp. 121-130,
2006.
[6]. Varol, Y. and Oztop, H.F., “A comparative numerical
study on natural convection in inclined wavy and flat-plate
solar collectors”, Building and Environment, Volume 43,
pp. 1535-1544, 2008.
[7]. Akpinar, E.K. Kocyigit, F., “Experimental investigation
of thermal performance of solar air heater having different
obstacles on absorber plates”, International Communications
in Heat and Mass Transfer, Volume 37(4), pp. 416-421.
2010.
[8]. Gertzos, K.P. and Caouris, Y.G., “Experimental and
computational study of the developed flow field in a flat
plate integrated collector storage (ICS) solar device with
recirculation”, Experimental Thermal and Fluid Science,
Volume 31, pp. 1133-1145, 2007.
[9]. Wang, C., Guan, Z., Zhao, X., and Wang, D.,
”Numerical Simulation Study on Transpired Solar Air
Collector” Renewable Energy Resources and a Greener
Future, Volume 8, pp 3-4, 2006.
[10]. Selmi, M., Al-Khawaja, M.J., and Marafia, A., “
Validation of CFD simulation for flat plate solar energy
collector”, Renewable Energy, Volume 33, pp. 383-387,
2008,
[11]. Ho, C., Chen, T., and Tsai, C., “Experimental and
theoretical studies of re-cyclic flat-plate solar water heaters
equipped with rectangle conduits”, Renewable Energy,
Volume 35(10), pp. 2279-2287, 2010.
[12]. Kumar, A. and Prasad, B.N., “Investigation of twisted
tape inserted solar water heaters-heat transfer friction factor
and thermal performance results”, Renewable Energy,
Volume 19, pp. 379-398, 2000.
BIOGRAPHIES
Dr. K. Vasudeva Karanth is working as a faculty in the
department of mechanical and manufacturing department of
Manipal Institute of Technology. Manipal 576104. Email:
kv.karanth@manipal.edu
Mr. Madhwesh N. is working as a faculty in the department
of mechanical and manufacturing department of Manipal
Institute of Technology. Manipal 576104. email:
madhwesh.n@gmail.com
Dr. Shiva Kumar is working as a faculty in the department
of mechanical and manufacturing department of Manipal
Institute of Technology. Manipal 576104.
Email:shiva_katipalla@yahoo.co.in
Mr. Manjunath M.S. is working as a faculty in the
department of mechanical and manufacturing department of
Manipal Institute of Technology. Manipal 576104. Email:
manjunathnitc@gmail.com

Weitere ähnliche Inhalte

Was ist angesagt?

Design and economical of roof trusses & purlins (comparison of limit state an...
Design and economical of roof trusses & purlins (comparison of limit state an...Design and economical of roof trusses & purlins (comparison of limit state an...
Design and economical of roof trusses & purlins (comparison of limit state an...
eSAT Publishing House
 
Design study of stressed mirror polishing (smp) fixture
Design study of stressed mirror polishing (smp) fixtureDesign study of stressed mirror polishing (smp) fixture
Design study of stressed mirror polishing (smp) fixture
eSAT Journals
 
Dg3211151122
Dg3211151122Dg3211151122
Dg3211151122
IJMER
 

Was ist angesagt? (20)

Cfd Studies of Two Stroke Petrol Engine Scavenging
Cfd Studies of Two Stroke Petrol Engine ScavengingCfd Studies of Two Stroke Petrol Engine Scavenging
Cfd Studies of Two Stroke Petrol Engine Scavenging
 
Design and economical of roof trusses & purlins (comparison of limit state an...
Design and economical of roof trusses & purlins (comparison of limit state an...Design and economical of roof trusses & purlins (comparison of limit state an...
Design and economical of roof trusses & purlins (comparison of limit state an...
 
Cfd thermal analysis on laptop cooling system using loop heat pipe technology
Cfd thermal analysis on laptop cooling system using loop heat pipe technologyCfd thermal analysis on laptop cooling system using loop heat pipe technology
Cfd thermal analysis on laptop cooling system using loop heat pipe technology
 
Effect of process parameters on tensile strength in gas metal arc welded join...
Effect of process parameters on tensile strength in gas metal arc welded join...Effect of process parameters on tensile strength in gas metal arc welded join...
Effect of process parameters on tensile strength in gas metal arc welded join...
 
Effect of process parameters on tensile strength in gas metal arc welded join...
Effect of process parameters on tensile strength in gas metal arc welded join...Effect of process parameters on tensile strength in gas metal arc welded join...
Effect of process parameters on tensile strength in gas metal arc welded join...
 
Design study of stressed mirror polishing (smp) fixture
Design study of stressed mirror polishing (smp) fixtureDesign study of stressed mirror polishing (smp) fixture
Design study of stressed mirror polishing (smp) fixture
 
Study on Influence of Inverted V and W-Frame Column Support on Dynamic Behavi...
Study on Influence of Inverted V and W-Frame Column Support on Dynamic Behavi...Study on Influence of Inverted V and W-Frame Column Support on Dynamic Behavi...
Study on Influence of Inverted V and W-Frame Column Support on Dynamic Behavi...
 
An octo coding technique to reduce energy transition
An octo coding technique to reduce energy transitionAn octo coding technique to reduce energy transition
An octo coding technique to reduce energy transition
 
IRJET- Multi-Objective Optimization of Shell and Tube Heat Exchanger – A Case...
IRJET- Multi-Objective Optimization of Shell and Tube Heat Exchanger – A Case...IRJET- Multi-Objective Optimization of Shell and Tube Heat Exchanger – A Case...
IRJET- Multi-Objective Optimization of Shell and Tube Heat Exchanger – A Case...
 
An octo coding technique to reduce energy transition in low power vlsi circuits
An octo coding technique to reduce energy transition in low power vlsi circuitsAn octo coding technique to reduce energy transition in low power vlsi circuits
An octo coding technique to reduce energy transition in low power vlsi circuits
 
A hybrid algorithm for voltage stability enhancement of distribution systems
A hybrid algorithm for voltage stability enhancement of distribution systems A hybrid algorithm for voltage stability enhancement of distribution systems
A hybrid algorithm for voltage stability enhancement of distribution systems
 
IRJET- Fatigue Life Estimation of Small Gas Turbine Blisk
IRJET-  	  Fatigue Life Estimation of Small Gas Turbine BliskIRJET-  	  Fatigue Life Estimation of Small Gas Turbine Blisk
IRJET- Fatigue Life Estimation of Small Gas Turbine Blisk
 
Application of finite element analysis in effective design of flight control ...
Application of finite element analysis in effective design of flight control ...Application of finite element analysis in effective design of flight control ...
Application of finite element analysis in effective design of flight control ...
 
Behaviour of fibre reinforce concrete beam in pure torsion
Behaviour of fibre reinforce concrete beam in pure torsionBehaviour of fibre reinforce concrete beam in pure torsion
Behaviour of fibre reinforce concrete beam in pure torsion
 
A computational approach for evaluating helical compression springs
A computational approach for evaluating helical compression springsA computational approach for evaluating helical compression springs
A computational approach for evaluating helical compression springs
 
One-dimensional Lumped-Circuit for Transient Thermal Study of an Induction El...
One-dimensional Lumped-Circuit for Transient Thermal Study of an Induction El...One-dimensional Lumped-Circuit for Transient Thermal Study of an Induction El...
One-dimensional Lumped-Circuit for Transient Thermal Study of an Induction El...
 
Optimizing the process parameters of friction stir butt welded joint on alumi...
Optimizing the process parameters of friction stir butt welded joint on alumi...Optimizing the process parameters of friction stir butt welded joint on alumi...
Optimizing the process parameters of friction stir butt welded joint on alumi...
 
VIBRATION ANALYSIS FOR DAMAGE DETECTION IN COMPOSITE PLATE BY USING PIEZOELEC...
VIBRATION ANALYSIS FOR DAMAGE DETECTION IN COMPOSITE PLATE BY USING PIEZOELEC...VIBRATION ANALYSIS FOR DAMAGE DETECTION IN COMPOSITE PLATE BY USING PIEZOELEC...
VIBRATION ANALYSIS FOR DAMAGE DETECTION IN COMPOSITE PLATE BY USING PIEZOELEC...
 
Modal analysis of Support bracket for air compressor system
Modal analysis of Support bracket for air compressor systemModal analysis of Support bracket for air compressor system
Modal analysis of Support bracket for air compressor system
 
Dg3211151122
Dg3211151122Dg3211151122
Dg3211151122
 

Ähnlich wie Numerical and experimental study of a solar water heater for enhancement in thermal performance

Enhancement of the output power generated from a hybrid solar thermal system
Enhancement of the output power generated from a hybrid solar thermal systemEnhancement of the output power generated from a hybrid solar thermal system
Enhancement of the output power generated from a hybrid solar thermal system
eSAT Journals
 
Numerical analysis of heat transfer in refrigerant flow through a condenser tube
Numerical analysis of heat transfer in refrigerant flow through a condenser tubeNumerical analysis of heat transfer in refrigerant flow through a condenser tube
Numerical analysis of heat transfer in refrigerant flow through a condenser tube
eSAT Journals
 
Numerical analysis of heat transfer in refrigerant flow through a condenser tube
Numerical analysis of heat transfer in refrigerant flow through a condenser tubeNumerical analysis of heat transfer in refrigerant flow through a condenser tube
Numerical analysis of heat transfer in refrigerant flow through a condenser tube
eSAT Publishing House
 
Thermal analysis of water cooled charge air cooler in turbo charged diesel en...
Thermal analysis of water cooled charge air cooler in turbo charged diesel en...Thermal analysis of water cooled charge air cooler in turbo charged diesel en...
Thermal analysis of water cooled charge air cooler in turbo charged diesel en...
eSAT Journals
 
Numerical analysis of geothermal tunnels
Numerical analysis of geothermal tunnelsNumerical analysis of geothermal tunnels
Numerical analysis of geothermal tunnels
eSAT Journals
 
An approach to evaluate the heat exchanger retrofit for installed industrial ...
An approach to evaluate the heat exchanger retrofit for installed industrial ...An approach to evaluate the heat exchanger retrofit for installed industrial ...
An approach to evaluate the heat exchanger retrofit for installed industrial ...
eSAT Journals
 

Ähnlich wie Numerical and experimental study of a solar water heater for enhancement in thermal performance (20)

Enhancement of the output power generated from a hybrid solar thermal system
Enhancement of the output power generated from a hybrid solar thermal systemEnhancement of the output power generated from a hybrid solar thermal system
Enhancement of the output power generated from a hybrid solar thermal system
 
Enhancement of the output power generated from a
Enhancement of the output power generated from aEnhancement of the output power generated from a
Enhancement of the output power generated from a
 
Optimization of condenser using microchannel
Optimization of condenser using microchannelOptimization of condenser using microchannel
Optimization of condenser using microchannel
 
IRJET - Analysis of Solar Flat Plate Collector using Heat Transfer Enhancer A...
IRJET - Analysis of Solar Flat Plate Collector using Heat Transfer Enhancer A...IRJET - Analysis of Solar Flat Plate Collector using Heat Transfer Enhancer A...
IRJET - Analysis of Solar Flat Plate Collector using Heat Transfer Enhancer A...
 
Novel technique for maximizing the thermal efficiency of a hybrid pv
Novel technique for maximizing the thermal efficiency of a hybrid pvNovel technique for maximizing the thermal efficiency of a hybrid pv
Novel technique for maximizing the thermal efficiency of a hybrid pv
 
A comparatively analysis of plate type H.E. and helical type H.E. using ANOVA...
A comparatively analysis of plate type H.E. and helical type H.E. using ANOVA...A comparatively analysis of plate type H.E. and helical type H.E. using ANOVA...
A comparatively analysis of plate type H.E. and helical type H.E. using ANOVA...
 
Numerical analysis of heat transfer in refrigerant flow through a condenser tube
Numerical analysis of heat transfer in refrigerant flow through a condenser tubeNumerical analysis of heat transfer in refrigerant flow through a condenser tube
Numerical analysis of heat transfer in refrigerant flow through a condenser tube
 
Numerical analysis of heat transfer in refrigerant flow through a condenser tube
Numerical analysis of heat transfer in refrigerant flow through a condenser tubeNumerical analysis of heat transfer in refrigerant flow through a condenser tube
Numerical analysis of heat transfer in refrigerant flow through a condenser tube
 
CFD Simulation of Solar Air Heater having Inclined Discrete Rib Roughness wit...
CFD Simulation of Solar Air Heater having Inclined Discrete Rib Roughness wit...CFD Simulation of Solar Air Heater having Inclined Discrete Rib Roughness wit...
CFD Simulation of Solar Air Heater having Inclined Discrete Rib Roughness wit...
 
IRJET- A Review of Solar Water Heater Performance Factors
IRJET- A Review of Solar Water Heater Performance FactorsIRJET- A Review of Solar Water Heater Performance Factors
IRJET- A Review of Solar Water Heater Performance Factors
 
Thermal analysis of water cooled charge air cooler in turbo charged diesel en...
Thermal analysis of water cooled charge air cooler in turbo charged diesel en...Thermal analysis of water cooled charge air cooler in turbo charged diesel en...
Thermal analysis of water cooled charge air cooler in turbo charged diesel en...
 
Novel technique for maximizing the thermal efficiency
Novel technique for maximizing the thermal efficiencyNovel technique for maximizing the thermal efficiency
Novel technique for maximizing the thermal efficiency
 
Numerical analysis of geothermal tunnels
Numerical analysis of geothermal tunnelsNumerical analysis of geothermal tunnels
Numerical analysis of geothermal tunnels
 
IRJET- Thermal Analysis on Solar Air Heater Duct
IRJET- Thermal Analysis on Solar Air Heater DuctIRJET- Thermal Analysis on Solar Air Heater Duct
IRJET- Thermal Analysis on Solar Air Heater Duct
 
An approach to evaluate the heat exchanger retrofit for installed industrial ...
An approach to evaluate the heat exchanger retrofit for installed industrial ...An approach to evaluate the heat exchanger retrofit for installed industrial ...
An approach to evaluate the heat exchanger retrofit for installed industrial ...
 
Experimental studies on pressure drop in a sinusoidal plate heat exchanger ef...
Experimental studies on pressure drop in a sinusoidal plate heat exchanger ef...Experimental studies on pressure drop in a sinusoidal plate heat exchanger ef...
Experimental studies on pressure drop in a sinusoidal plate heat exchanger ef...
 
Experimental studies on pressure drop in a sinusoidal plate heat exchanger
Experimental studies on pressure drop in a sinusoidal plate heat exchangerExperimental studies on pressure drop in a sinusoidal plate heat exchanger
Experimental studies on pressure drop in a sinusoidal plate heat exchanger
 
IRJET- An Experimental Investigations of Twisted Tape Inserts in Square and C...
IRJET- An Experimental Investigations of Twisted Tape Inserts in Square and C...IRJET- An Experimental Investigations of Twisted Tape Inserts in Square and C...
IRJET- An Experimental Investigations of Twisted Tape Inserts in Square and C...
 
Experimental investigation of flow condensation in 'v' shaped minichannel
Experimental investigation of flow condensation in 'v' shaped minichannelExperimental investigation of flow condensation in 'v' shaped minichannel
Experimental investigation of flow condensation in 'v' shaped minichannel
 
IRJET-Study of Space Cooling System Consisting of Aluminium Ammonia Heat Pipe...
IRJET-Study of Space Cooling System Consisting of Aluminium Ammonia Heat Pipe...IRJET-Study of Space Cooling System Consisting of Aluminium Ammonia Heat Pipe...
IRJET-Study of Space Cooling System Consisting of Aluminium Ammonia Heat Pipe...
 

Mehr von eSAT Journals

Material management in construction – a case study
Material management in construction – a case studyMaterial management in construction – a case study
Material management in construction – a case study
eSAT Journals
 
Laboratory studies of dense bituminous mixes ii with reclaimed asphalt materials
Laboratory studies of dense bituminous mixes ii with reclaimed asphalt materialsLaboratory studies of dense bituminous mixes ii with reclaimed asphalt materials
Laboratory studies of dense bituminous mixes ii with reclaimed asphalt materials
eSAT Journals
 
Geographical information system (gis) for water resources management
Geographical information system (gis) for water resources managementGeographical information system (gis) for water resources management
Geographical information system (gis) for water resources management
eSAT Journals
 
Estimation of surface runoff in nallur amanikere watershed using scs cn method
Estimation of surface runoff in nallur amanikere watershed using scs cn methodEstimation of surface runoff in nallur amanikere watershed using scs cn method
Estimation of surface runoff in nallur amanikere watershed using scs cn method
eSAT Journals
 
Effect of variation of plastic hinge length on the results of non linear anal...
Effect of variation of plastic hinge length on the results of non linear anal...Effect of variation of plastic hinge length on the results of non linear anal...
Effect of variation of plastic hinge length on the results of non linear anal...
eSAT Journals
 

Mehr von eSAT Journals (20)

Mechanical properties of hybrid fiber reinforced concrete for pavements
Mechanical properties of hybrid fiber reinforced concrete for pavementsMechanical properties of hybrid fiber reinforced concrete for pavements
Mechanical properties of hybrid fiber reinforced concrete for pavements
 
Material management in construction – a case study
Material management in construction – a case studyMaterial management in construction – a case study
Material management in construction – a case study
 
Managing drought short term strategies in semi arid regions a case study
Managing drought    short term strategies in semi arid regions  a case studyManaging drought    short term strategies in semi arid regions  a case study
Managing drought short term strategies in semi arid regions a case study
 
Life cycle cost analysis of overlay for an urban road in bangalore
Life cycle cost analysis of overlay for an urban road in bangaloreLife cycle cost analysis of overlay for an urban road in bangalore
Life cycle cost analysis of overlay for an urban road in bangalore
 
Laboratory studies of dense bituminous mixes ii with reclaimed asphalt materials
Laboratory studies of dense bituminous mixes ii with reclaimed asphalt materialsLaboratory studies of dense bituminous mixes ii with reclaimed asphalt materials
Laboratory studies of dense bituminous mixes ii with reclaimed asphalt materials
 
Laboratory investigation of expansive soil stabilized with natural inorganic ...
Laboratory investigation of expansive soil stabilized with natural inorganic ...Laboratory investigation of expansive soil stabilized with natural inorganic ...
Laboratory investigation of expansive soil stabilized with natural inorganic ...
 
Influence of reinforcement on the behavior of hollow concrete block masonry p...
Influence of reinforcement on the behavior of hollow concrete block masonry p...Influence of reinforcement on the behavior of hollow concrete block masonry p...
Influence of reinforcement on the behavior of hollow concrete block masonry p...
 
Influence of compaction energy on soil stabilized with chemical stabilizer
Influence of compaction energy on soil stabilized with chemical stabilizerInfluence of compaction energy on soil stabilized with chemical stabilizer
Influence of compaction energy on soil stabilized with chemical stabilizer
 
Geographical information system (gis) for water resources management
Geographical information system (gis) for water resources managementGeographical information system (gis) for water resources management
Geographical information system (gis) for water resources management
 
Forest type mapping of bidar forest division, karnataka using geoinformatics ...
Forest type mapping of bidar forest division, karnataka using geoinformatics ...Forest type mapping of bidar forest division, karnataka using geoinformatics ...
Forest type mapping of bidar forest division, karnataka using geoinformatics ...
 
Factors influencing compressive strength of geopolymer concrete
Factors influencing compressive strength of geopolymer concreteFactors influencing compressive strength of geopolymer concrete
Factors influencing compressive strength of geopolymer concrete
 
Experimental investigation on circular hollow steel columns in filled with li...
Experimental investigation on circular hollow steel columns in filled with li...Experimental investigation on circular hollow steel columns in filled with li...
Experimental investigation on circular hollow steel columns in filled with li...
 
Experimental behavior of circular hsscfrc filled steel tubular columns under ...
Experimental behavior of circular hsscfrc filled steel tubular columns under ...Experimental behavior of circular hsscfrc filled steel tubular columns under ...
Experimental behavior of circular hsscfrc filled steel tubular columns under ...
 
Evaluation of punching shear in flat slabs
Evaluation of punching shear in flat slabsEvaluation of punching shear in flat slabs
Evaluation of punching shear in flat slabs
 
Evaluation of performance of intake tower dam for recent earthquake in india
Evaluation of performance of intake tower dam for recent earthquake in indiaEvaluation of performance of intake tower dam for recent earthquake in india
Evaluation of performance of intake tower dam for recent earthquake in india
 
Evaluation of operational efficiency of urban road network using travel time ...
Evaluation of operational efficiency of urban road network using travel time ...Evaluation of operational efficiency of urban road network using travel time ...
Evaluation of operational efficiency of urban road network using travel time ...
 
Estimation of surface runoff in nallur amanikere watershed using scs cn method
Estimation of surface runoff in nallur amanikere watershed using scs cn methodEstimation of surface runoff in nallur amanikere watershed using scs cn method
Estimation of surface runoff in nallur amanikere watershed using scs cn method
 
Estimation of morphometric parameters and runoff using rs & gis techniques
Estimation of morphometric parameters and runoff using rs & gis techniquesEstimation of morphometric parameters and runoff using rs & gis techniques
Estimation of morphometric parameters and runoff using rs & gis techniques
 
Effect of variation of plastic hinge length on the results of non linear anal...
Effect of variation of plastic hinge length on the results of non linear anal...Effect of variation of plastic hinge length on the results of non linear anal...
Effect of variation of plastic hinge length on the results of non linear anal...
 
Effect of use of recycled materials on indirect tensile strength of asphalt c...
Effect of use of recycled materials on indirect tensile strength of asphalt c...Effect of use of recycled materials on indirect tensile strength of asphalt c...
Effect of use of recycled materials on indirect tensile strength of asphalt c...
 

Kürzlich hochgeladen

DeepFakes presentation : brief idea of DeepFakes
DeepFakes presentation : brief idea of DeepFakesDeepFakes presentation : brief idea of DeepFakes
DeepFakes presentation : brief idea of DeepFakes
MayuraD1
 
Verification of thevenin's theorem for BEEE Lab (1).pptx
Verification of thevenin's theorem for BEEE Lab (1).pptxVerification of thevenin's theorem for BEEE Lab (1).pptx
Verification of thevenin's theorem for BEEE Lab (1).pptx
chumtiyababu
 

Kürzlich hochgeladen (20)

Engineering Drawing focus on projection of planes
Engineering Drawing focus on projection of planesEngineering Drawing focus on projection of planes
Engineering Drawing focus on projection of planes
 
Thermal Engineering Unit - I & II . ppt
Thermal Engineering  Unit - I & II . pptThermal Engineering  Unit - I & II . ppt
Thermal Engineering Unit - I & II . ppt
 
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
 
S1S2 B.Arch MGU - HOA1&2 Module 3 -Temple Architecture of Kerala.pptx
S1S2 B.Arch MGU - HOA1&2 Module 3 -Temple Architecture of Kerala.pptxS1S2 B.Arch MGU - HOA1&2 Module 3 -Temple Architecture of Kerala.pptx
S1S2 B.Arch MGU - HOA1&2 Module 3 -Temple Architecture of Kerala.pptx
 
Employee leave management system project.
Employee leave management system project.Employee leave management system project.
Employee leave management system project.
 
DeepFakes presentation : brief idea of DeepFakes
DeepFakes presentation : brief idea of DeepFakesDeepFakes presentation : brief idea of DeepFakes
DeepFakes presentation : brief idea of DeepFakes
 
Design For Accessibility: Getting it right from the start
Design For Accessibility: Getting it right from the startDesign For Accessibility: Getting it right from the start
Design For Accessibility: Getting it right from the start
 
Generative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPTGenerative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPT
 
A Study of Urban Area Plan for Pabna Municipality
A Study of Urban Area Plan for Pabna MunicipalityA Study of Urban Area Plan for Pabna Municipality
A Study of Urban Area Plan for Pabna Municipality
 
Online food ordering system project report.pdf
Online food ordering system project report.pdfOnline food ordering system project report.pdf
Online food ordering system project report.pdf
 
Thermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.pptThermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.ppt
 
Verification of thevenin's theorem for BEEE Lab (1).pptx
Verification of thevenin's theorem for BEEE Lab (1).pptxVerification of thevenin's theorem for BEEE Lab (1).pptx
Verification of thevenin's theorem for BEEE Lab (1).pptx
 
COST-EFFETIVE and Energy Efficient BUILDINGS ptx
COST-EFFETIVE  and Energy Efficient BUILDINGS ptxCOST-EFFETIVE  and Energy Efficient BUILDINGS ptx
COST-EFFETIVE and Energy Efficient BUILDINGS ptx
 
DC MACHINE-Motoring and generation, Armature circuit equation
DC MACHINE-Motoring and generation, Armature circuit equationDC MACHINE-Motoring and generation, Armature circuit equation
DC MACHINE-Motoring and generation, Armature circuit equation
 
A CASE STUDY ON CERAMIC INDUSTRY OF BANGLADESH.pptx
A CASE STUDY ON CERAMIC INDUSTRY OF BANGLADESH.pptxA CASE STUDY ON CERAMIC INDUSTRY OF BANGLADESH.pptx
A CASE STUDY ON CERAMIC INDUSTRY OF BANGLADESH.pptx
 
GEAR TRAIN- BASIC CONCEPTS AND WORKING PRINCIPLE
GEAR TRAIN- BASIC CONCEPTS AND WORKING PRINCIPLEGEAR TRAIN- BASIC CONCEPTS AND WORKING PRINCIPLE
GEAR TRAIN- BASIC CONCEPTS AND WORKING PRINCIPLE
 
HAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKAR
HAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKARHAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKAR
HAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKAR
 
Orlando’s Arnold Palmer Hospital Layout Strategy-1.pptx
Orlando’s Arnold Palmer Hospital Layout Strategy-1.pptxOrlando’s Arnold Palmer Hospital Layout Strategy-1.pptx
Orlando’s Arnold Palmer Hospital Layout Strategy-1.pptx
 
Unleashing the Power of the SORA AI lastest leap
Unleashing the Power of the SORA AI lastest leapUnleashing the Power of the SORA AI lastest leap
Unleashing the Power of the SORA AI lastest leap
 
Bhubaneswar🌹Call Girls Bhubaneswar ❤Komal 9777949614 💟 Full Trusted CALL GIRL...
Bhubaneswar🌹Call Girls Bhubaneswar ❤Komal 9777949614 💟 Full Trusted CALL GIRL...Bhubaneswar🌹Call Girls Bhubaneswar ❤Komal 9777949614 💟 Full Trusted CALL GIRL...
Bhubaneswar🌹Call Girls Bhubaneswar ❤Komal 9777949614 💟 Full Trusted CALL GIRL...
 

Numerical and experimental study of a solar water heater for enhancement in thermal performance

  • 1. IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 _______________________________________________________________________________________ Volume: 04 Issue: 03 | Mar-2015, Available @ http://www.ijret.org 548 NUMERICAL AND EXPERIMENTAL STUDY OF A SOLAR WATER HEATER FOR ENHANCEMENT IN THERMAL PERFORMANCE K. Vasudeva Karanth1 , Madhwesh N2 , Shiva Kumar3 , Manjunath M.S4 1 Corresponding Author, Department of Mechanical & Mfg. Engineering, M. I. T., Manipal, Karnataka, India 2 Department of Mechanical & Mfg. Engineering, Manipal Institute of Technology, Manipal, Karnataka, India 3 Department of Mechanical & Mfg. Engineering, Manipal Institute of Technology, Manipal, Karnataka, India 4 Department of Mechanical & Mfg. Engineering, Manipal Institute of Technology, Manipal, Karnataka, India Abstract Largest commercial application amongst the various solar collectors is the solar flat plate collectors mainly due to its simple design as well as low maintenance cost. Numerical analysis of the solar water heater which involves conduction and convection due to radiation heat transfer using Computational Fluid Dynamics (CFD) as a tool has not been the focus of study so far. It is generally understood that sinusoidal flow passage tends to increase turbulence which in turn increases convective heat transfer. The advantage of using straight absorber tube over sinusoidal absorber tube on the thermal behavior of the solar water heater needs to be explored as a design prescription. In the study presented in this paper it is noted from the experimental and numerical analysis that the straight tube configuration has better performance than that of sinusoidal pipe configuration. Keywords: Sinusoidal tube, Solar water heater, Convective heat transfer, Computational fluid dynamics. --------------------------------------------------------------------***---------------------------------------------------------------------- 1. INTRODUCTION Solar flat plate collectors even though produce lower temperature rise, they are simpler in design and have lower maintenance cost. Solar collector is a complex heat exchanger that transfers radiation heat from the sun to the working fluid. Kumar & Rosen [2] explored the performance of an integrated solar water heater using corrugated absorber plate. The absorber plate surface is considered to be corrugated with small indentation depths. They results revealed that solar water heater had higher operating temperature for longer time as compared to the flat absorber plate. Prasad et al [3] conducted an experimental study on a flat plate water heater with sun tracking mechanism. The found that the thermal efficiency increased by about 21%.Varol and Oztop [4] numerically examined the fluid flow and heat transfer in a collector with wavy absorber plate. The results showed that higher Rayleigh number and aspect ratio increases the heat transfer while increasing the wavelength decreases the heat transfer. Karim and Hawlader [5] carried out an experimental analysis on V-groove air heating system under the operating conditions of Singapore. They found that the V-corrugations provided improved thermal efficiency as compared to a flat plate collector. Varol and Oztop [6] carried out a CFD analysis of natural convection heat transfer inside the inclined wavy solar collectors and flat-plate solar collectors. They found that the fluid flow and heat transfer are affected by the geometry of enclosure and augments the heat transfer as compared to the flat enclosure. Akpinar and Kocyigit [7] conducted an experimental analysis on a novel flat plate solar air heater fitted with several obstacles to provide turbulence in the fluid flow. They found that the presence of obstacles significantly increases the heat transfer. Gertzos and Caouris [8] conducted an experimental and numerical analysis on an integrated collector storage solar device with recirculation and established a validated three-dimensional CFD model. Wang et al. [9] conducted a numerical simulation on transpired solar air collector and found that the collector has significant advantages in the ventilation preheating area and also proves that CFD tools have their own advantages in the solar air collector research area. Selmi et al. [10] conducted a validated CFD model for flat plate solar water heater. Ho et al. [11] carried out an experimental and theoretical analysis of recyclic flat-plate solar water heater equipped with rectangle conduits. They found that the collector efficiency increases with increasing flow conduit aspect ratio and recycle ratio. Kumar and Prasad [12] found that use of twisted tape inserts inside the water tube increases the efficiency by 18-70% with a pressure drop of 87-132% as compared to ordinary collectors. It is observed from the literature review of solar water heaters that numerical analysis of the solar water heater which involves conduction and convection due to radiation heat on the sine wave absorber tube using CFD has not been the focus of study so far. It is generally understood that sinusoidal flow passage tends to increase turbulence which in turn increases convective heat transfer. The advantage of using straight absorber tube over sinusoidal absorber tube on the performance of the solar water heater needs to be explored as a design prescription. Hence in this study a CFD analysis is carried out to explore the efficacy of sine wave absorber tube over straight absorber tube
  • 2. IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 _______________________________________________________________________________________ Volume: 04 Issue: 03 | Mar-2015, Available @ http://www.ijret.org 549 2. NUMERICAL ANALYSIS 2.1 Geometry Description and Assumptions Fig.1. Straight tube configuration of solar water heater Fig.2. Sinewave configuration of solar water heater The flow domain consists of an absorber plate of 1 .2 m length, 195 mm wide and 0.5 mm thickness. An absorber tube of 12.5 mm diameter and 0.65 mm thickness is attached below the absorber plate. The absorber plate and the absorber tube are insulated with glass wool of 25 mm thickness. The water tube is attached to the absorber plate by placing it centrally with a small angle of lap. The first configuration adopted in the study is a straight absorber tube as shown in figure 1. The second configuration is a tube of sine wave geometry having a wave length of 0.6 m and amplitude of 30 mm as shown in figure 2. The assumptions made in the analysis are, a) Water is a continuous medium and incompressible. b) The flow is steady and possesses laminar flow characteristics, at lower velocity and turbulent characteristics at higher velocity. C) The thermal-physical properties of the absorber plate and the absorber tube are constant with respect to the operating temperature. 2.2 Numerical Method Numerical simulation is carried out with steady state implicit pressure based solver using the Fluent 14.5 code [1]. The governing partial differential equations for mass and momentum are solved for the steady state flows. The pressure-velocity coupling is carried out using the SIMPLE algorithm [1]. Discretization is done using the second order upwind scheme. 2.3 Mean Flow Equations All the equations are presented in Cartesian tensor notation. Continuity: ( ) 0 (1)i i U x     Momentum equation ( ) (2) ji i j i j j i j j i UUP U U u u x x x x x                       Energy equation ( ) (3) Pr i i j j j T U T u t x x x                2.4 Numerical Scheme Fig.3 Localized cross sectional view of the meshed computational domain The three dimensional computational domain is modeled using hex mesh and a localized view of the mesh is shown in Figure 3. The complete domain consists of 1.5 million elements which include the water, water tube absorber plate and insulating material. The grid independence test was performed to obtain an optimal mesh for the computational domain. It was found that further refinement of mesh size did not change the result by more than 1 % which is taken here as the optimal mesh quality for computation. Steady state simulation is carried out to establish the flow and thermal characteristics of the solar water heater models with straight and sinewave tube. Convergence was considered when all the scaled residuals fell below 10-5 in the computational domain. 2.5 Boundary Conditions and Operating Parameters A ‘mass flow inlet’ boundary condition is specified at the inlet and an ‘outflow’ condition is specified at the outlet for the water continuum. The mass flow rate for the numerical study is as obtained from the experimental study. Wall boundary conditions were used to bound fluid and solid
  • 3. IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 _______________________________________________________________________________________ Volume: 04 Issue: 03 | Mar-2015, Available @ http://www.ijret.org 550 regions. At the wall, no-slip and impermeability conditions are applied. The interface between the water and the absorber tube is defined as wall with coupled condition to effect conjugate heat transfer from absorber tube to the water. A standard k  model is adopted in the analysis to take into account the turbulence that might occur in the flow domain. In order to numerically establish the effectiveness of the two configurations of water heater adopted in the analysis, the numerical models are modeled with approximately the same number of elements and identical boundary conditions are applied. The performance parameters adopted for comparison of the two configurations are i) the Nusselt number (Nu) and ii) the convective heat transfer coefficient (h). The temperature coefficient CT is calculated using Eq.(4) where, T0 is the water inlet temperature. Length ratio for the flow path is taken as Lr = l/L, where L = 1.2 m. 0 0 T T T C T   (4) 3. EXPERIMENTAL SETUP The solar water heater structure is fabricated using half inch thick plywood material and is 1.2 m long, 0.22 m wide and 0.05 m in height. The upper surface is made up of a 0.5 mm thick copper plate which is the absorber plate exposed to solar radiation. The absorber plate is painted black for absorbing the heat due to solar radiation. RTD (Resistance Temperature Detectors) type thermocouples are at the inlet, outlet and the absorber plate for measuring the water temperature and the absorber plate temperature. The heat flux that is incident on the absorber plate due to solar irradiation is measured using a Pyranometer. The experimentation was carried out between 1130 a.m. to 1.30 p.m. when the average heat flux as recorded by the pyranometer was noted to be 810W/m2 . The experiments were carried out for 4 different mass flow rates of 20ml/min, 63 ml/min, 198ml/min and 360 ml/min. 4. RESULTS AND DISCUSSION The numerical, analysis is carried out after the experimental study of the two collectors is conducted and the mass flow rates adopted in the experimental study are taken as the input for the numerical analysis. 0 50 100 150 200 250 300 350 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 Temperaturerisecoefficient(CT ) Mass flow rate (ml) Numerical value Experimental value Fig. 5 Absorber fluid temperature rise coefficient corresponding to various mass flow rates for sine wave tube configuration Fig. 4 shows the validation plot for the temperature rise coefficients of the absorber fluid corresponding to the four mass flow rates for straight tube configuration. It can be observed from this graph that at lower mass flow rates the experimental and numerical values of the absorber fluid temperature coefficients vary with a large difference. However at higher mass flow rates, the temperature coefficients for experimental and numerical analysis come closer with a matching trend line. The same trend is observed for sine wave configuration as can be seen in Fig. 5. The large gap between the numerical and experimental results at lower mass flow rates can be attributed to the heat loss that takes place across the boundaries which are not accounted in the numerical analysis which assumes ideal insulating conditions. 0 50 100 150 200 250 300 350 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 Temperaturerisecoefficient(CT ) Mass flow rate (ml) Numerical value Experimental value Fig. 4 Absorber fluid temperature rise coefficient corresponding to various mass flow rates for straight tube configuration
  • 4. IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 _______________________________________________________________________________________ Volume: 04 Issue: 03 | Mar-2015, Available @ http://www.ijret.org 551 0.0 0.2 0.4 0.6 0.8 1.0 0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 Absorberfluidtemperaturerisecoefficient(CT ) Length ratio (Lr ) 360 ml/min 198 ml/min 63 ml/min 20 ml/min Fig. 6 Absorber fluid temperature rise coefficient along the flow length of the tube for straight tube configuration The simulation is carried out at 4 different mass flow rates and fig 6 shows the plot for temperature rise coefficient along the flow length of the absorber tube. From this plot it is seen that, as the absorber plate is uniformly heated corresponding to various mass flow rates, the fluid in the absorber tube gets differentially heated with significant temperature gradient for lower mass flow rate followed by a smaller temperature gradient for higher mass flow rates. The numerical analysis is carried out so as to meet the convergence criteria and the two configurations are compared in terms of its thermal performance. The numerical results for the two configurations are presented in terms of the Nusselt number (Nu) and the convective heat transfer coefficient (h) as shown in figures 7 and 8. It can be observed from the bar diagrams of figure 7 that the Nusselt number for configuration with straight absorber tube is higher than that of the sine wave tube configuration for the given mass flow rate and heat flux on the absorber plate. This can be attributed to the fact that the fluid in the sine wave tube has to traverse a larger distance compared to that of straight tube configuration for the given mass flow rate and hence reducing the speed of the flow. This leads to a lower convective heat transfer that is taking place to the fluid (fig 8.) and hence reducing the Nusselt number. 82.227 151.035 220.142 246.321 81.590 149.811 218.661 244.085 0 50 100 150 200 250 360 ml/min198ml/min63 ml/min20 ml/min Nusseltnumber(Nu) Mass flow rate (ml/min) Straight tube configuration Sinewave tube configuration Fig.7. Bar charts of Nusselt number for the two configurations. 54.724 97.697 139.604 155.19 54.288 96.880 138.536 153.769 0 25 50 75 100 125 150 175 360 ml/min198ml/min63 ml/min20 ml/min Convectiveheattransfer coefficient(w/m2 k) Mass flow rate (ml/min) Straight tube configuration Sinewave tube configuration Fig.8. Bar charts of convective heat transfer coefficients for the two configurations. Fig.9 (a) and Fig.9(b) show temperature contour plots of the absorber plate for sine wave and straight tube configurations at a lower mass flow rate of 20 ml/min. This is in comparison with the temperature contour plot for the same configuration at higher mass flow rate of 360 ml/min as shown in figures 10a and10b. It can be noted from these plots that the heat transfer from the absorber plate to the absorber tube is uniform in case of straight tube configuration whereas for sinewave configuration the heat transfer is more near the absorber tube and hence a non-uniform distribution of temperature is observed for the absorber plate. This non uniform heat transfer that takes place from absorber plate to the absorber tube can also be attributed to the lower Nusselt number and convective heat transfer for the sinewave tube configuration.
  • 5. IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 _______________________________________________________________________________________ Volume: 04 Issue: 03 | Mar-2015, Available @ http://www.ijret.org 552 Fig.9(a). Absorber plate temperature contour plot for sinusoidal tube configuration at 20ml/min Fig.9(b). Absorber plate temperature contour plot for straight tube configuration at 20ml/min Fig.10(a). Absorber plate temperature contour plot for sinusoidal tube configuration at a mass flow rate of 360 ml/min Fig.10(b). Absorber plate temperature contour plot for straight tube configuration at 360 ml/min 5. CONCLUSION Numerical study helps in understanding the complex heat transfer phenomena that takes place in a solar water heater and helps in quantifying the thermal performance which is otherwise not possible through experimentation due to the small difference in the temperatures outputs for the two comparable configurations. The following conclusions can be drawn from the numerical study.  The Nusselt number for the straight tube configuration is higher than that of sine wave tube configurations of solar water heater for the given identical boundary conditions.  The convective heat transfer coefficient is higher for straight tube configuration for all the mass flow rates compared to sine wave configuration.  Non uniform heating of the absorber plate takes place for sine wave configuration. Hence as a design prescription, it can be perceived that the straight absorber tube configuration has a better heat transfer capability compared to sine wave absorber tube configuration. ACKNOWLEDGEMENTS The computational facilities were provided by the Department of Mechanical and Manufacturing Engineering, Manipal Institute of Technology, Manipal, India which is appreciatively acknowledged. NOMENCLATURE T Temperature CT Temperature rise coefficient L Length of the collector Lr Non-dimensional collector length (x/L) U Velocity ρ Density µ Viscosity Pr Prandtl Number Nu Nusselt number
  • 6. IJRET: International Journal of Research in Engineering and Technology eISSN: 2319-1163 | pISSN: 2321-7308 _______________________________________________________________________________________ Volume: 04 Issue: 03 | Mar-2015, Available @ http://www.ijret.org 553 REFERENCES [1]. ANSYS Fluent 14.5 User’s manual, Ansys Inc. (2013) [2]. Kumar, A. Prasad, B.N., “Investigation of twisted tape inserted solar water heaters-heat transfer, friction factor and thermal performance results” Journal of Renewable Energy, Volume 19, pp. 379-398.. 2000. [3]. Prasad, P.R., Byregowda, H.V., and Gangavati, P.B., “Experiment Analysis of Flat Plate Collector and Comparison of Performance with Tracking Collecto”,. European Journal of Scientific Research, 40(1), pp. 144 - 155, 2010. [4]. Varol, Y. & Oztop, H.F., “Buoyancy induced heat transfer and fluid flow inside a tilted wavy solar collector. Building and Environment, Volume 42, pp. 2062-2071, 2007. [5]. Karim, A. Hawlader, M.N.A., “Performance evaluation of a v-groove solar air collector for drying applications”, Applied Thermal Engineering, Volume 26, pp. 121-130, 2006. [6]. Varol, Y. and Oztop, H.F., “A comparative numerical study on natural convection in inclined wavy and flat-plate solar collectors”, Building and Environment, Volume 43, pp. 1535-1544, 2008. [7]. Akpinar, E.K. Kocyigit, F., “Experimental investigation of thermal performance of solar air heater having different obstacles on absorber plates”, International Communications in Heat and Mass Transfer, Volume 37(4), pp. 416-421. 2010. [8]. Gertzos, K.P. and Caouris, Y.G., “Experimental and computational study of the developed flow field in a flat plate integrated collector storage (ICS) solar device with recirculation”, Experimental Thermal and Fluid Science, Volume 31, pp. 1133-1145, 2007. [9]. Wang, C., Guan, Z., Zhao, X., and Wang, D., ”Numerical Simulation Study on Transpired Solar Air Collector” Renewable Energy Resources and a Greener Future, Volume 8, pp 3-4, 2006. [10]. Selmi, M., Al-Khawaja, M.J., and Marafia, A., “ Validation of CFD simulation for flat plate solar energy collector”, Renewable Energy, Volume 33, pp. 383-387, 2008, [11]. Ho, C., Chen, T., and Tsai, C., “Experimental and theoretical studies of re-cyclic flat-plate solar water heaters equipped with rectangle conduits”, Renewable Energy, Volume 35(10), pp. 2279-2287, 2010. [12]. Kumar, A. and Prasad, B.N., “Investigation of twisted tape inserted solar water heaters-heat transfer friction factor and thermal performance results”, Renewable Energy, Volume 19, pp. 379-398, 2000. BIOGRAPHIES Dr. K. Vasudeva Karanth is working as a faculty in the department of mechanical and manufacturing department of Manipal Institute of Technology. Manipal 576104. Email: kv.karanth@manipal.edu Mr. Madhwesh N. is working as a faculty in the department of mechanical and manufacturing department of Manipal Institute of Technology. Manipal 576104. email: madhwesh.n@gmail.com Dr. Shiva Kumar is working as a faculty in the department of mechanical and manufacturing department of Manipal Institute of Technology. Manipal 576104. Email:shiva_katipalla@yahoo.co.in Mr. Manjunath M.S. is working as a faculty in the department of mechanical and manufacturing department of Manipal Institute of Technology. Manipal 576104. Email: manjunathnitc@gmail.com