SlideShare ist ein Scribd-Unternehmen logo
1 von 10
Downloaden Sie, um offline zu lesen
University of Salerno
                                   Department of Civil Engineering

                                 Contact Person: Luigi Petti, petti@unisa.it




                                     REPORT
               INNOVATIVE PROCEDURES TO ASSESS
           SEISMIC BEHAVIOUR OF EXISTING STRUCTURES
            BY MEANS OF NON LINEAR STATIC ANALYSIS:
              POLAR SPECTRUM & CAPACITY DOMAINS
                               Luigi Petti, Ivana Marino


INTRODUCTION
As known, the standard analysis for traditional seismic design is Linear Dynamic
Procedure (LDP) with assigned response spectrum (Response Spectrum Analysis). More
complex procedures, such as non-linear time history analysis (NDP), are seldom used
because of the difficulties in the definition of an accurate hysteretic model to describe the
behaviour of the materials under cyclic actions and the choice of a set of accelerograms
that describes the real site conditions. Moreover, as it is well-known, NDP analyses present
convergence difficulties and require major computational effort.
Non-linear static analysis is instead becoming the key method to evaluate the seismic
response of existing structures. This method, which is able to evaluate the collapse
mechanism of structures, is suitable for the analysis of structures not explicitly designed
for seismic actions.
However, non-linear static procedures can lead to unsuitable results when applied to
irregular structures because of the difficulties in taking into account dynamic latero-
torsional effects. As it is known, an asymmetric distribution of mass and stiffness, or of
strength in plan, leads to high ductility demand for the elements near the soft or weak edge.
In the last years, several proposals have been put forward to extend traditional pushover
analysis, calibrated on plan systems, to the assessment of three-dimensional models
behaviour. At present no simplified procedure which can adequately account for the
torsional behaviour of asymmetric structures is implemented. The main questions concern
the combination of the forces in the two directions, and the best way to consider extra
ductility demand for the elements near the edges.
This report presents and discusses the main results of the new methodology to assess the
seismic response of irregular structures by means of capacity domains which allow us to
evaluate the direction of least seismic capacity of the investigated buildings and polar
spectrum which representing the seismic demand in plan. In particular, the capacity
domains, represented in terms of strength and displacement capacities, are evaluated using
traditional pushover analyses by applying load distributions, triangular and uniform, at
different angles in plan to search for the least seismic - resistant direction. The polar



                                             1
spectrum, instead, is a new spectral representation which are able to investigate the seismic
demand each in-plane direction. In particular, this tool is based on the spatial spectral
surface obtained by the spectral seismic response evaluated for different in-plan directions
and the in-plan projection is defined “Polar Spectrum”.
Both polar spectrum and capacity domains allow researchers to investigate the non-linear
seismic capacities of irregular structures. As is well-known, indeed, the collapse conditions
for a three-dimensional system are also governed by the spatial features of the seismic
event. Therefore, the goal of the presented results is to investigate the seismic behaviour of
irregular structures by considering the least seismic-resistant directions of the investigated
structure and the spatial features of the seismic event.


DESCRIPTION OF THE BENCHMARK STRUCTURE

To the scope of this report the benchmark structure proposed in the ReLUIS project (Rete
dei Laboratori Universitari di Ingegneria Sismica – Earthquake Engineering Test Labs
Network) is considered.
The structure, designed without seismic actions, is a five-storey L-shaped building with RC
moment frames in two orthogonal directions, as represented in Figure 1. Details of the
benchmark structure are contained in the ReLUIS project.
                            Y




                       e



                       d


                       c


                       b
                       a
                                                                        X

                                1      2        3        4         5
                                    Fig. 1 – Benchmark Structure Plan

A finite-element model has been implemented in Opensees software. The floors are
modelled by means of 50mm elastic shells and the elastic modulus is set to the value of
30000MPa. Beams and columns are modelled by spread plasticity non-linear elements with
fiber sections applied.
The collapse condition for the generic section is defined in terms of section curvature,
evaluated by imposing limit strain values for the concrete fibers (c=0,006 in compression)
and for the reinforced steel fibers (s=0,03 in tension).
The main dynamical properties of the model are reported in the Table 1. In particular, each
mode shape is described by the vibration period (T), the mass participation ratios (M%)
and the sum of the participation ratios up to the considered modal shape (SUM).



                                                   2
Modo     T(s)    M%x M%y SumX             SumY
                          1       1,35   10,9% 52,1% 10,9%         52,1%
                          2       1,22   56,9% 19,6% 67,8%         71,8%
                          3       0,99   10,8% 9,2% 78,6%          80,9%
                          4       0,42   0,9% 8,5% 79,4%           89,4%
                          5       0,38   9,4% 1,9% 88,8%           91,2%
                          6       0,31   1,5% 1,1% 90,3%           92,4%
                          7       0,23   0,1% 4,1% 90,4%           96,5%
                          8       0,20   4,2% 0,5% 94,6%           97,0%
                          9       0,17   0,9% 0,5% 95,5%           97,5%
                      Table 1 - Modal properties for the Benchmark Structure


THE CONCEPT OF THE CAPACITY DOMAINS

In order to assess the non-linear static response of irregular structures it is possible to
obtain capacity domains, in terms of control node displacement or base shear. In particular,
such domains are obtained from the results of non-linear static procedures (pushover)
carried out by varying the in-plan direction of the applied load distribution. The domains,
represented in the following, depict the displacement of the control node or the base shear
up to collapse.
The analyses are carried out by applying two load distributions along the height of the
structure. The first one is a triangular distribution, taking into consideration the inertial
masses and the height above the ground. The second one considers only the floor masses.
The forces are applied at beam-column joints, proportionally to the joints mass.
For each applied load distribution, 24 capacity curves have been obtained by rotating the
direction of action in the x-y plane, 15° at each step. The control node is assumed to be the
centre of mass on the top floor in all the pushover analyses carried out.
Using the described limit values for section curvature, the global collapse is assumed when
the first primary element exceeds its limit. Each pushover curve is bi-linearized according
to the FEMA 356 procedure.
The capacity domains are compared to the non-linear dynamic response to recorded
earthquake, selected among those proposed by ReLUIS. The records, considering both NS
and EW components, are suitably scaled to study the structural response by varying
ground acceleration as in the case of non linear incremental analysis (IDA).
The main results are represented in the following. In particular, the figures 2 and 3refer to
the collapse of the analyzed benchmark structure by varying the direction of action in the
plan in the case of triangular (TR) and uniform (UN) load distributions and represent the
capacity domains. These domains are plotted in terms of displacement of the control node
(U) and shear base (Vb). As it is possible to observe for both domains a non-regular
behaviour of the structure above all in terms of limit displacements. In particular, the
analyses show that the benchmark structure presents lower displacement capacities in the
150°- 330° direction. Otherwise, structural behaviour seems to be more regular in terms of
strength.




                                                3
U (cm)
                                                                                                                                                    Vb (kN)

                                                90                                                                                                      90
                                    105    20                 75                                                                           105 3000                  75
                            120                                        60                                                         120                                      60
                                                                                                                                                 2500
                      135                  15                                45                                             135                                                   45
                                                                                                                                                 2000

                150                        10                                      30                                 150                        1500                                   30

                                                                                                                                                 1000
          165                                                                           15                    165                                                                            15
                                            5
                                                                                                                                                 500

                                                                                                            180                                    0                                          0
          180                               0                                            0

                                                                                                              195                                                                            345
          195                                                                           345

                                                                                                                      210                                                               330
                210                                                                330
                                                                                                                            225                                                   315
                      225                                                    315
                                                                                                                                  240                                      300
                                                                                                                                                                                                   UN
                            240                                        300                                                                 255                       285
                                                                                               UN                                                                                                  TR
                                    255                       285                                                                                       270
                                                270                                            TR




   Fig. 2 - Capacity Domains in terms of node control                                                     Fig. 3 - Capacity Domains in terms of base shear
               displacements at collapse
In order to evaluate the applicability of the capacity domains to accurately describe the
collapse state of a structure, incremental dynamic analyses have been performed. For both
the considered in-plan dispositions of the structures, 0° and 90°, the analyses have been
carried out considering the Iceland 2000 earthquake (code 06334, maximum PGA equal to
7,07m/s2). The figures 4-7 show the dynamic response (NDP) for the analyzed cases.

                                                   0,2                                                                                                        3000


                                                  0,15
                                                                                                                                                              2000

                                                   0,1


                                                                                                                                                              1000
                                                  0,05
 Uy (m)




                                                                                                            Vy (kN)




                                                      0
                                                                                                                                                                0
           -0,2        -0,15      -0,1    -0,05           0         0,05     0,1        0,15    0,2
                                                                                                                      -3000        -2000         -1000               0          1000          2000      3000
                                                -0,05
                                                                                                                                                             -1000
                                                  -0,1


                                                                                                                                                             -2000
                                                -0,15


                                                  -0,2
                                                                                                                                                             -3000
                                                   Ux (m)
                                                                                                                                                               Vx (kN)

                      NSP uniform                         NSP Triangular                        NDP                         NSP uniform                              NSP Triangular                     NDP

 Fig. 4 – Comparition between capacity domains and                                                          Fig. 5 - Comparition between capacitys domain and
  NDP - Collapse amplification factor 0.40 - In plan                                                         NDP - Collapse amplification factor 0.40 - In plan
         orientation of benchmark structure 0°                                                                      orientation of benchmark structure 0°




                                                                                                      4
0,20                                                                                                   3000


                                           0,15
                                                                                                                                                  2000

                                           0,10


                                                                                                                                                  1000
                                           0,05
 Uy (m)




                                                                                                            Vy (kN)
                                           0,00
                                                                                                                                                     0
          -0,20    -0,15   -0,10   -0,05       0,00      0,05       0,10     0,15    0,20
                                                                                                                      -3000      -2000    -1000           0      1000      2000   3000
                                       -0,05
                                                                                                                                                  -1000
                                       -0,10


                                                                                                                                                  -2000
                                       -0,15


                                       -0,20
                                                                                                                                                  -3000
                                            Ux (m)
                                                                                                                                                    Vx (kN)

                  NSP uniform                     NSP Triangular                    NDP                                   NSP uniform                     NSP Triangular          NDP

 Fig. 6 – Comparition between capacity domains and                                                      Fig. 7 - Comparition between capacity domains and
  NDP - Collapse amplification factor 0.35 - In plan                                                     NDP - Collapse amplification factor 0.35- In plan
        orientation of benchmark structure 90°                                                                 orientation of benchmark structure 90°


As it is possible to observe, the collapse is attained in the direction of about 255°
independently by plan orientation of benchmark structure. Moreover, the collapse occurs in
correspondence of the capacity domain for triangular load distribution, and the collapsed
element, column 15 at ground level, is the same for both dynamic and static analyses. For
both analyses the collapse amplification factor in the case of NDP is represented. In the
figures, the capacity domains are indicated with NSP (Non-linear Static Procedure) for the
uniform and triangular load distributions.
As a further comparison between static and dynamic responses, figure 8 shows storey
displacements at collapse for both analyses in the considered plan directions of benchmark
structure (0° and 90°).
                                                         5                                              5



                                                         4                                              4



                                                         3                                              3
                                                   imp




                                                                                                  imp




                                                         2                                              2



                                                         1                                              1



                                                         0                                              0
                                                             0         0,1          0,2                       0                0,1       0,2
                                                                     U (m)                                                    U (m)


                                                                 NSP uniform                    NSP Triangular                           NDP


                                               Fig. 8 – Storey Displacement Comparison at collapse
                                                          for in plan directions 0° and 90°



                                                                                            5
Results show that the collapse mechanism is a global one, being the displacement path
carried out by NDP well described by the one obtained by NSP with triangular load
distribution. Moreover, as it is possible to observe, the collapse as well as read with NDP
procedure intercepts always the capacity domains corresponding to triangular load
distribution (outer domain in figures 4 and 6 and inner domain in figures 5 and 7).

THE CONCEPT OF “POLAR SPECTRUM”

As known, seismic events generally present a strong directivity effects due to site geo-
morphological conditions, source mechanism and path from source to the site of the
seismic waves.
To take into account the directivity and site effects it is possible to refer to polar spectrum,
a new tool, proposed by authors, which is able to investigate each in-plan direction. In
particular, this tool is based on the spatial spectral surface obtained by the spectral seismic
response evaluated for different in-plan directions and the in-plan projection of this surface
is defined “Polar Spectrum”.
Figure 9 shows the polar spectrum in terms of pseudo-acceleration for the seismic event
South Iceland aftershock (code 006334) with a damping factor =0,05 in the range of
periods 0-2 seconds. In particular, the spectral surface has been obtained by considering
the NS and EW components of recorded accelerograms projected along each direction in
plan. In correspondence of each radius, the spectrum response evaluated in that direction is
represented. In correspondence to each circumference, instead, the spectral demand for a
fixed period is plotted for each considered direction. The origin corresponds to 0 sec
period. As it is easy to observe, the polar spectrum is a polar-symmetric figure.




       Fig. 9 – Polar Spectrum in terms of pseudo-acceleration for South Iceland aftershock (code 006334)


The analysis of polar spectrum shows that the considered seismic event presents a peak
demand along the direction (75°-255°) regardless of the vibration period value.
The comparison between the polar spectrum of the considered seismic event and the results
of Non-Linear Dynamic Procedure (NDP) shows clearly as the collapse of the benchmark
structure are controlled by the directivity effects more than seismic capacity of the
analyzed structure.

“CRITICAL” ALIGNMENT

The possibility of evaluating the worst structural response moving from observation of the
polar spectrum suggests performing dynamic analyses with the structure oriented so that its


                                                   6
least capacity direction (assessed by means of the capacity domains) is aligned with the
maximum seismic demand (evaluated by means of the polar spectrum).
Figure 10 depicts the results in this case. In particular, the structure is been rotated 105°
counter-clockwise in order to match the least resistant direction (=150°- 330°) with the
maximum spectral seismic demand direction (75°- 255°).
                                                                   0,20


                                                                   0,15


                                                                   0,10


                                                                   0,05
                          Uy (m)




                                                                   0,00
                                   -0,20   -0,15   -0,10   -0,05       0,00   0,05   0,10   0,15   0,20

                                                               -0,05


                                                               -0,10


                                                               -0,15


                                                               -0,20

                                                                    Ux (m)
        Fig. 10 – Dynamic analyses results, in plan orientation of the benchmark structure 240°,
                               NDP collapse amplification factor 0.30

The obtained results show that when the least seismic resistance direction is aligned with
the maximum seismic demand, the minimum collapse amplification factor is reached.


SOFTWARE IMPLEMENTATION

A first implementation of the capacity domains could be found in the software
IPERSPACE which leads to evaluate these domains in terms of limit states according to
the Italian Design Code (NTC 2008). As an example, the following figures represent the
main results obtained with Iperspace software for the analyzed benchmark structure:




        Fig.11- Capacity Domains in terms of node control displacements at collapse (on the left)
                and maximum base shear (on the right) obtained with Iperspace Software


                                                                      7
The modest difference between the capacity domains obtained by Iperspace and by
Opensees is due to the adopted collapse criteria. In the case of Iperspace, the NTC2008
collapse criterion has been considered by controlling the ultimate plastic hinge rotation of
RC members.


CONCLUDING REMARKS

The report shows new tools in order to assess the non-linear behaviour of a irregular
building and the spectral seismic demand in plan. In particular, the capacity domains are
evaluated by means of pushover analyses by varying the load distribution in plan and lead
to search for less seismic resistant directions. The polar spectra lead to a fully assessment
of the spatial features of the seismic demand and represent an opportunity to investigate
thoroughly the seismic demand and the event characteristics, being able to clearly evaluate
directivity and site effects.
From the obtained results it is possible to observe that:
   The collapse condition, assessed by means of non-linear dynamic procedures, turns out
    to be coherent with the capacity domains based on the results of traditional non-linear
    static procedures carried out by varying the angle of the application of the load
    distribution;
   The non-linear dynamic analyses have shown that the directional components of the
    seismic event govern the collapse direction;
   The worst condition for a structure is obtained by aligning its least resistance capacity
    direction, evaluated on the basis of the capacity domains, with the maximum response
    demand direction identified by the polar spectrum.



REFERENCES

Ayala A. G. and Tavera, E. A. [2002], “A new approach for the evaluation of the seismic
performance of asymmetric buildings”, Proc. of the 7th National Conference on Earthquake
Engineering, Boston.
Chopra A. K. and Goel, R. K. [2004], “A modal pushover analysis procedure to estimate seismic
demands for unsymmetric-plan buildings”, Earthquake Engineering and Structural Dynamics
33(8), pp. 903-927.
Chopra A. K. [2008]. Application of modal pushover analysis to RC frames and Incremental
Dynamic Analysis. Nonlinear Static Methods for Design/Assessment of 3D Structures, 5-6 May
2008, Lisbon, Portugal.
Faella G. and Kilar V. [1998], “Asymmetric multistory R/C frame structures: push-over versus
nonlinear dynamic analysis”, Proc., 11th Eur. Conf. Earth. Engrg., A.A. Balkema, Rotterdam.
Fajfar P. [2000], “A nonlinear analysis method for performance-based seismic design”, Earthquake
Spectra 16(3), pp. 573-592.
Fajfar, P. [2002], “Structural analysis in earthquake engineering - a breakthrough of simplified
nonlinear methods”, Proc. of the 12th European Conference on Earthquake Engineering, London,
UK, Keynote lecture.
Fajfar P. and Gaspersic P. [1996], “The N2 method for the seismic damage analysis of RC
buildings”, Earthquake Engineering and Structural Dynamics 25, pp. 23-67.



                                               8
Fajfar P. and Kilar V. [1997], “Simple push-over analysis of asymmetric buildings”, Earthquake
Engineering and Structural Dynamics, Vol. 26, pp. 233-249.
Fajfar P., Kilar V., Marusic D., Perus I. and Magliulo G. [2002], “The extension of the N2 method
to asymmetric buildings”, Proc. of the fourth forum on Implications of recent earthquakes on
seismic risk, Technical report TIT/EERG, 02/1, Tokyo Institute of Technology, Tokyo, pp. 291-
308.
Fajfar P., Marusic D. and Perus I. [2004], “Influence of ground motion intensity on the inelastic
torsional response of asymmetric buildings”, Proc. of the 13th World Conference on Earthquake
Engineering, Vancouver, Canada, Paper No. 3496.
Fajfar P., Marusic D. and Perus I. [2005], “Torsional effects in the pushover-based seismic analysis
of buildings”, Journal of Earthquake Engineering, Vol. 9, No. 6, pp. 831-854.
Fajfar P., Marusic D., Perus I., Kreslin M. [2008]. “The N2 method for asymmetric buildings”,
Nonlinear Static Methods for Design/Assessment of 3D Structures, 5-6 May 2008, Lisbon,
Portugal.
Fujii K., Nakano Y. and Sanada Y. [2004], “Simplified nonlinear analysis procedure for
asymmetric buildings”, Proc. of the 13th World Conference on Earthquake Engineering,
Vancouver, Canada, Paper No. 149.
Goel R. K. [2008] Generalized pushover curves for nonlinear static analysis of three dimensional
structures. Nonlinear Static Methods for Design/Assessment of 3D Structures, 5-6 May 2008,
Lisbon, Portugal.
Hejal R. and Chopra A. [1987], “Earthquake response of torsionally-coupled buildings”, Report
UCB/EERC-87/20.
Kan C. L. and Chopra A. K. [1979], “Linear and nonlinear earthquake responses of simple
torsionally coupled systems”, Report UCB/EERC-79/03.
Kilar V. and Fajfar P. [2001], “On the applicability of pushover analysis to the seismic
performance evaluation of asymmetric buildings”, European Earthquake Engineering 15, pp. 20-
31.
Marino I., Petti L. [2011], “Seismic Assessment of Asymmetric Structures Behaviour by using
Static Non-Linear Analysis”, in corso di stampa sulla rivista Journal of Civil Engineering and
Architecture ISSN 1934-7359.
Moghadam A. S. and Tso K. [2000], “Pushover analysis for asymmetric and set-back multistory
buildings”, Proc. of the 12th World Conference on Earthquake Engineering, Auckland, New
Zealand, Paper No. 1093.
Open System for Earthquake Engineering Simulation (OpenSEES), Pacific Earthquake
Engineering Research Center, University of California, Berkley (USA);
Petti L., Marino I., Cuoco L., Palazzo B. [2008], “Assessment of Seismic Response of Plan-
Asymmetric Structures through simplified Static Nonlinear Analyses”, Proc.the 14th World
Conference on Earthquake Engineeering, Beijing, China.
Pettinga J. D., Priestley M. J. N., Pampanin S., Christopulos C. [2007], “The Role of Inelastic
Torsion in the Determination of Residual Deformations”, Journal of Earthquake Engineering, vo.l
11 2007, supplement 1, Proceedings of the Sixth ROSE Seminar.
ReLUIS project - Rete dei Laboratori Universitari di Ingegneria Sismica – Earthquake Engineering
Test Labs Network, www.reluis.unina.it.
Reyes C. Juan and Anil K. Chopra [2011], “Evaluation of three-dimensional modal pushover
analysis for unsymmetric-plan buildings subjected to two components of ground motion”,
Earthquake Engineering and Structural Dynamics; 40:1475 -1494.




                                                 9
Rutenberg A. [2002], EAEE Task Group (TG) 8: “Behaviour of irregular and complex structures
asymmetric structures - progress since 1998”, Proc. of the 12th European Conference on
Earthquake Engineering, London, UK, Paper No. 832.
Rutenberg A., Levy R. and Magliulo G. [2002], “Seismic response of asymmetric perimeter frame
steel buildings”, Proc. of the 12th European Conference on Earthquake Engineering, London, UK,
Paper No. 107.
Soft.lab, Software Partnership http://www.soft.lab.it, Via Borgo II° - 82030 - PONTE (BN) -
IT, IperSpace Max
Tso W. K. and Moghadam A. S. [1997], “Seismic response of asymmetrical buildings using
pushover analysis”, Proc. of the International Workshop on Seismic Design Methodologies for the
Next Generation of Codes, Bled, Slovenia, eds. P. Fajfar and H. Krawinkler (A.A. Balkema,
Roterdam, Brookfield), pp. 311-321.
Tso W. K. and Myslimaj B. [2002], “Effect of strength distribution on the inelastic torsional
response of asymmetric structural systems”, Proc. of the 12th European Conference on Earthquake
Engineering, London, UK, Paper No. 081.
Yu Q.S.K., Pugliesi R., Allen M. and Bischoff C. [2004], “Assessment of modal pushover analysis
procedure and its application to seismic evaluation of existing building”, Proc. of the 13th World
Conference on Earthquake Engineering, Vancouver, Canada, Paper No. 1104.
Zarate A. and Ayala A. G. [2004], “Validation of single storey models for the evaluation of seismic
performance of multi-storey asymmetric buildings”, Proc. of the 13th World Conference on
Earthquake Engineering, Vancouver, Canada, Paper No. 2213.




                                                10

Weitere ähnliche Inhalte

Was ist angesagt?

REPORT ON QUALITY CONTROL BY REDUCING REJECTION DUE TO CHIP IMPRESSION
REPORT ON QUALITY CONTROL BY REDUCING REJECTION DUE TO CHIP IMPRESSIONREPORT ON QUALITY CONTROL BY REDUCING REJECTION DUE TO CHIP IMPRESSION
REPORT ON QUALITY CONTROL BY REDUCING REJECTION DUE TO CHIP IMPRESSIONHardik Ramani
 
Influence lines for_indeterminate_beams_and_frames
Influence lines for_indeterminate_beams_and_framesInfluence lines for_indeterminate_beams_and_frames
Influence lines for_indeterminate_beams_and_framesTanmoy Sinha
 
3 strain transformations
3 strain transformations3 strain transformations
3 strain transformationsLisa Benson
 
Influence lines (structural analysis theories)
Influence lines (structural analysis theories)Influence lines (structural analysis theories)
Influence lines (structural analysis theories)Madujith Sagara
 
Advanced mathematical analysis of chassis integrated platform designed for un...
Advanced mathematical analysis of chassis integrated platform designed for un...Advanced mathematical analysis of chassis integrated platform designed for un...
Advanced mathematical analysis of chassis integrated platform designed for un...Dr.Vikas Deulgaonkar
 
Summary of CHAPTER 6 (ACI318-14M) Structural Analysis
Summary of CHAPTER 6 (ACI318-14M) Structural AnalysisSummary of CHAPTER 6 (ACI318-14M) Structural Analysis
Summary of CHAPTER 6 (ACI318-14M) Structural AnalysisAbdullah Khair
 
Structural analysis 2
Structural analysis   2Structural analysis   2
Structural analysis 2R VIJAYAKUMAR
 
Continuity in RC beams and frames-AFM (Complete).pdf
Continuity in RC beams and frames-AFM (Complete).pdfContinuity in RC beams and frames-AFM (Complete).pdf
Continuity in RC beams and frames-AFM (Complete).pdfaslhal
 
Influence line for structure analysis in civil engineering
Influence line for structure analysis in civil engineeringInfluence line for structure analysis in civil engineering
Influence line for structure analysis in civil engineeringNagma Modi
 
IRJET- Behaviour of Tuned Mass Dampers on Dynamic Response of Structure u...
IRJET-  	  Behaviour of Tuned Mass Dampers on Dynamic Response of Structure u...IRJET-  	  Behaviour of Tuned Mass Dampers on Dynamic Response of Structure u...
IRJET- Behaviour of Tuned Mass Dampers on Dynamic Response of Structure u...IRJET Journal
 
Failure of slender and stocky columns (2nd year)
Failure of slender and stocky columns (2nd year)Failure of slender and stocky columns (2nd year)
Failure of slender and stocky columns (2nd year)Alessandro Palmeri
 
Lesson 05,bending and shearing stresses
Lesson 05,bending and shearing stressesLesson 05,bending and shearing stresses
Lesson 05,bending and shearing stressesMsheer Bargaray
 
Enhancement of bending strength of helical gears by using asymmetric involute...
Enhancement of bending strength of helical gears by using asymmetric involute...Enhancement of bending strength of helical gears by using asymmetric involute...
Enhancement of bending strength of helical gears by using asymmetric involute...Omar Sabah
 
Estimation of passenger vehicle r wade-allen
Estimation of passenger vehicle  r wade-allenEstimation of passenger vehicle  r wade-allen
Estimation of passenger vehicle r wade-allenMikeSantos Lousath
 
Influence line of reaction for determinate structure: determining maximum /mi...
Influence line of reaction for determinate structure: determining maximum /mi...Influence line of reaction for determinate structure: determining maximum /mi...
Influence line of reaction for determinate structure: determining maximum /mi...Rifat Hassan
 

Was ist angesagt? (19)

REPORT ON QUALITY CONTROL BY REDUCING REJECTION DUE TO CHIP IMPRESSION
REPORT ON QUALITY CONTROL BY REDUCING REJECTION DUE TO CHIP IMPRESSIONREPORT ON QUALITY CONTROL BY REDUCING REJECTION DUE TO CHIP IMPRESSION
REPORT ON QUALITY CONTROL BY REDUCING REJECTION DUE TO CHIP IMPRESSION
 
Complex stresses (2nd year)
Complex stresses (2nd year)Complex stresses (2nd year)
Complex stresses (2nd year)
 
Muller breslau
Muller breslauMuller breslau
Muller breslau
 
Influence lines for_indeterminate_beams_and_frames
Influence lines for_indeterminate_beams_and_framesInfluence lines for_indeterminate_beams_and_frames
Influence lines for_indeterminate_beams_and_frames
 
3 strain transformations
3 strain transformations3 strain transformations
3 strain transformations
 
Influence lines (structural analysis theories)
Influence lines (structural analysis theories)Influence lines (structural analysis theories)
Influence lines (structural analysis theories)
 
Advanced mathematical analysis of chassis integrated platform designed for un...
Advanced mathematical analysis of chassis integrated platform designed for un...Advanced mathematical analysis of chassis integrated platform designed for un...
Advanced mathematical analysis of chassis integrated platform designed for un...
 
Summary of CHAPTER 6 (ACI318-14M) Structural Analysis
Summary of CHAPTER 6 (ACI318-14M) Structural AnalysisSummary of CHAPTER 6 (ACI318-14M) Structural Analysis
Summary of CHAPTER 6 (ACI318-14M) Structural Analysis
 
Structural analysis 2
Structural analysis   2Structural analysis   2
Structural analysis 2
 
Continuity in RC beams and frames-AFM (Complete).pdf
Continuity in RC beams and frames-AFM (Complete).pdfContinuity in RC beams and frames-AFM (Complete).pdf
Continuity in RC beams and frames-AFM (Complete).pdf
 
Influence line for structure analysis in civil engineering
Influence line for structure analysis in civil engineeringInfluence line for structure analysis in civil engineering
Influence line for structure analysis in civil engineering
 
IRJET- Behaviour of Tuned Mass Dampers on Dynamic Response of Structure u...
IRJET-  	  Behaviour of Tuned Mass Dampers on Dynamic Response of Structure u...IRJET-  	  Behaviour of Tuned Mass Dampers on Dynamic Response of Structure u...
IRJET- Behaviour of Tuned Mass Dampers on Dynamic Response of Structure u...
 
Failure of slender and stocky columns (2nd year)
Failure of slender and stocky columns (2nd year)Failure of slender and stocky columns (2nd year)
Failure of slender and stocky columns (2nd year)
 
Lesson 05,bending and shearing stresses
Lesson 05,bending and shearing stressesLesson 05,bending and shearing stresses
Lesson 05,bending and shearing stresses
 
Enhancement of bending strength of helical gears by using asymmetric involute...
Enhancement of bending strength of helical gears by using asymmetric involute...Enhancement of bending strength of helical gears by using asymmetric involute...
Enhancement of bending strength of helical gears by using asymmetric involute...
 
Estimation of passenger vehicle r wade-allen
Estimation of passenger vehicle  r wade-allenEstimation of passenger vehicle  r wade-allen
Estimation of passenger vehicle r wade-allen
 
seismic ubc -97
seismic ubc -97seismic ubc -97
seismic ubc -97
 
Influence line of reaction for determinate structure: determining maximum /mi...
Influence line of reaction for determinate structure: determining maximum /mi...Influence line of reaction for determinate structure: determining maximum /mi...
Influence line of reaction for determinate structure: determining maximum /mi...
 
Dimensional engineering
Dimensional engineeringDimensional engineering
Dimensional engineering
 

Andere mochten auch

Ascensore vetro rev.1
Ascensore vetro rev.1Ascensore vetro rev.1
Ascensore vetro rev.1Soft.lab Srl
 
Linear to Non-Linear Essay
Linear to Non-Linear EssayLinear to Non-Linear Essay
Linear to Non-Linear EssayRaja Rosenani
 
TYPES DATA STRUCTURES( LINEAR AND NON LINEAR)....
TYPES DATA STRUCTURES( LINEAR AND NON LINEAR)....TYPES DATA STRUCTURES( LINEAR AND NON LINEAR)....
TYPES DATA STRUCTURES( LINEAR AND NON LINEAR)....Shail Nakum
 
Non linear static pushover analysis
Non linear static pushover analysisNon linear static pushover analysis
Non linear static pushover analysisjeyanthi4
 
Non linear static pushover analysis of irregular space frame structure with a...
Non linear static pushover analysis of irregular space frame structure with a...Non linear static pushover analysis of irregular space frame structure with a...
Non linear static pushover analysis of irregular space frame structure with a...eSAT Publishing House
 

Andere mochten auch (6)

Ascensore vetro rev.1
Ascensore vetro rev.1Ascensore vetro rev.1
Ascensore vetro rev.1
 
Linear to Non-Linear Essay
Linear to Non-Linear EssayLinear to Non-Linear Essay
Linear to Non-Linear Essay
 
TYPES DATA STRUCTURES( LINEAR AND NON LINEAR)....
TYPES DATA STRUCTURES( LINEAR AND NON LINEAR)....TYPES DATA STRUCTURES( LINEAR AND NON LINEAR)....
TYPES DATA STRUCTURES( LINEAR AND NON LINEAR)....
 
Non linear static pushover analysis
Non linear static pushover analysisNon linear static pushover analysis
Non linear static pushover analysis
 
Linear non linear
Linear non linearLinear non linear
Linear non linear
 
Non linear static pushover analysis of irregular space frame structure with a...
Non linear static pushover analysis of irregular space frame structure with a...Non linear static pushover analysis of irregular space frame structure with a...
Non linear static pushover analysis of irregular space frame structure with a...
 

Ähnlich wie Non linear static analysis aist petti_marino

8 new physical laws (sems) and civil engineering
8   new physical laws (sems) and civil engineering8   new physical laws (sems) and civil engineering
8 new physical laws (sems) and civil engineeringMiguel Cabral Martín
 
International Refereed Journal of Engineering and Science (IRJES)
International Refereed Journal of Engineering and Science (IRJES)International Refereed Journal of Engineering and Science (IRJES)
International Refereed Journal of Engineering and Science (IRJES)irjes
 
International Refereed Journal of Engineering and Science (IRJES)
International Refereed Journal of Engineering and Science (IRJES)International Refereed Journal of Engineering and Science (IRJES)
International Refereed Journal of Engineering and Science (IRJES)irjes
 
PSO and SMC based Closed Loop V/F Control of AC Drive using SVPWM
PSO and SMC based Closed Loop V/F Control of AC Drive using SVPWMPSO and SMC based Closed Loop V/F Control of AC Drive using SVPWM
PSO and SMC based Closed Loop V/F Control of AC Drive using SVPWMIRJET Journal
 
IRJET - An Investigation of Stresses Induced in Curved Beams using MATLAB...
IRJET -  	  An Investigation of Stresses Induced in Curved Beams using MATLAB...IRJET -  	  An Investigation of Stresses Induced in Curved Beams using MATLAB...
IRJET - An Investigation of Stresses Induced in Curved Beams using MATLAB...IRJET Journal
 
Shaped blade centeress_grinding_v0
Shaped blade centeress_grinding_v0Shaped blade centeress_grinding_v0
Shaped blade centeress_grinding_v0Marco Leonesio
 
Performing Pushover Analysis on High Rise Building With and Without Shear Wall
Performing Pushover Analysis on High Rise Building With and Without Shear WallPerforming Pushover Analysis on High Rise Building With and Without Shear Wall
Performing Pushover Analysis on High Rise Building With and Without Shear WallIRJET Journal
 
Design of Flat Slab and Bridges
Design of Flat Slab and BridgesDesign of Flat Slab and Bridges
Design of Flat Slab and BridgesAnanthakumar75
 
3.4 pushover analysis
3.4 pushover analysis3.4 pushover analysis
3.4 pushover analysisNASRIN AFROZ
 
Study on Effects of P-Delta Analysis on RC Structures
Study on Effects of P-Delta Analysis on RC StructuresStudy on Effects of P-Delta Analysis on RC Structures
Study on Effects of P-Delta Analysis on RC StructuresIRJET Journal
 
SCENARIO DAMAGE ANALYSIS OF RC PRECAST INDUSTRIAL STRUCTURES IN TUSCANY, ITALY
SCENARIO DAMAGE ANALYSIS OF RC PRECAST INDUSTRIAL STRUCTURES IN TUSCANY, ITALYSCENARIO DAMAGE ANALYSIS OF RC PRECAST INDUSTRIAL STRUCTURES IN TUSCANY, ITALY
SCENARIO DAMAGE ANALYSIS OF RC PRECAST INDUSTRIAL STRUCTURES IN TUSCANY, ITALYGlobal Earthquake Model Foundation
 
DYNAMIC RESPONSE OF SIMPLE SUPPORTED BEAM VIBRATED UNDER MOVING LOAD
DYNAMIC RESPONSE OF SIMPLE SUPPORTED BEAM VIBRATED UNDER MOVING LOAD DYNAMIC RESPONSE OF SIMPLE SUPPORTED BEAM VIBRATED UNDER MOVING LOAD
DYNAMIC RESPONSE OF SIMPLE SUPPORTED BEAM VIBRATED UNDER MOVING LOAD sadiq emad
 
Wear Analysis on Cylindrical Cam with Flexible Rod
Wear Analysis on Cylindrical Cam with Flexible RodWear Analysis on Cylindrical Cam with Flexible Rod
Wear Analysis on Cylindrical Cam with Flexible RodIJRES Journal
 
Seismic protection variable stiffness part 2 poster
Seismic protection variable stiffness part 2 poster Seismic protection variable stiffness part 2 poster
Seismic protection variable stiffness part 2 poster Neofytos Theodorou
 
Modeling and Simulation of Nonlinear Friction in XY AC Servo Table
Modeling and Simulation of Nonlinear Friction  in XY AC Servo Table Modeling and Simulation of Nonlinear Friction  in XY AC Servo Table
Modeling and Simulation of Nonlinear Friction in XY AC Servo Table Thuan Truongvan
 
Performance Evaluation of G+5, G+10 and G+15 Story Symmetric and Asymmetric B...
Performance Evaluation of G+5, G+10 and G+15 Story Symmetric and Asymmetric B...Performance Evaluation of G+5, G+10 and G+15 Story Symmetric and Asymmetric B...
Performance Evaluation of G+5, G+10 and G+15 Story Symmetric and Asymmetric B...IRJET Journal
 

Ähnlich wie Non linear static analysis aist petti_marino (20)

8 new physical laws (sems) and civil engineering
8   new physical laws (sems) and civil engineering8   new physical laws (sems) and civil engineering
8 new physical laws (sems) and civil engineering
 
International Refereed Journal of Engineering and Science (IRJES)
International Refereed Journal of Engineering and Science (IRJES)International Refereed Journal of Engineering and Science (IRJES)
International Refereed Journal of Engineering and Science (IRJES)
 
International Refereed Journal of Engineering and Science (IRJES)
International Refereed Journal of Engineering and Science (IRJES)International Refereed Journal of Engineering and Science (IRJES)
International Refereed Journal of Engineering and Science (IRJES)
 
PSO and SMC based Closed Loop V/F Control of AC Drive using SVPWM
PSO and SMC based Closed Loop V/F Control of AC Drive using SVPWMPSO and SMC based Closed Loop V/F Control of AC Drive using SVPWM
PSO and SMC based Closed Loop V/F Control of AC Drive using SVPWM
 
IRJET - An Investigation of Stresses Induced in Curved Beams using MATLAB...
IRJET -  	  An Investigation of Stresses Induced in Curved Beams using MATLAB...IRJET -  	  An Investigation of Stresses Induced in Curved Beams using MATLAB...
IRJET - An Investigation of Stresses Induced in Curved Beams using MATLAB...
 
Shaped blade centeress_grinding_v0
Shaped blade centeress_grinding_v0Shaped blade centeress_grinding_v0
Shaped blade centeress_grinding_v0
 
Performing Pushover Analysis on High Rise Building With and Without Shear Wall
Performing Pushover Analysis on High Rise Building With and Without Shear WallPerforming Pushover Analysis on High Rise Building With and Without Shear Wall
Performing Pushover Analysis on High Rise Building With and Without Shear Wall
 
Design of Flat Slab and Bridges
Design of Flat Slab and BridgesDesign of Flat Slab and Bridges
Design of Flat Slab and Bridges
 
3.4 pushover analysis
3.4 pushover analysis3.4 pushover analysis
3.4 pushover analysis
 
Study on Effects of P-Delta Analysis on RC Structures
Study on Effects of P-Delta Analysis on RC StructuresStudy on Effects of P-Delta Analysis on RC Structures
Study on Effects of P-Delta Analysis on RC Structures
 
SCENARIO DAMAGE ANALYSIS OF RC PRECAST INDUSTRIAL STRUCTURES IN TUSCANY, ITALY
SCENARIO DAMAGE ANALYSIS OF RC PRECAST INDUSTRIAL STRUCTURES IN TUSCANY, ITALYSCENARIO DAMAGE ANALYSIS OF RC PRECAST INDUSTRIAL STRUCTURES IN TUSCANY, ITALY
SCENARIO DAMAGE ANALYSIS OF RC PRECAST INDUSTRIAL STRUCTURES IN TUSCANY, ITALY
 
DYNAMIC RESPONSE OF SIMPLE SUPPORTED BEAM VIBRATED UNDER MOVING LOAD
DYNAMIC RESPONSE OF SIMPLE SUPPORTED BEAM VIBRATED UNDER MOVING LOAD DYNAMIC RESPONSE OF SIMPLE SUPPORTED BEAM VIBRATED UNDER MOVING LOAD
DYNAMIC RESPONSE OF SIMPLE SUPPORTED BEAM VIBRATED UNDER MOVING LOAD
 
Wce2013 pp1809 1814
Wce2013 pp1809 1814Wce2013 pp1809 1814
Wce2013 pp1809 1814
 
Wear Analysis on Cylindrical Cam with Flexible Rod
Wear Analysis on Cylindrical Cam with Flexible RodWear Analysis on Cylindrical Cam with Flexible Rod
Wear Analysis on Cylindrical Cam with Flexible Rod
 
Seismic protection variable stiffness part 2 poster
Seismic protection variable stiffness part 2 poster Seismic protection variable stiffness part 2 poster
Seismic protection variable stiffness part 2 poster
 
Seismic wharves and str
Seismic wharves and strSeismic wharves and str
Seismic wharves and str
 
Modeling and Simulation of Nonlinear Friction in XY AC Servo Table
Modeling and Simulation of Nonlinear Friction  in XY AC Servo Table Modeling and Simulation of Nonlinear Friction  in XY AC Servo Table
Modeling and Simulation of Nonlinear Friction in XY AC Servo Table
 
LNm5.pdf
LNm5.pdfLNm5.pdf
LNm5.pdf
 
D012211830
D012211830D012211830
D012211830
 
Performance Evaluation of G+5, G+10 and G+15 Story Symmetric and Asymmetric B...
Performance Evaluation of G+5, G+10 and G+15 Story Symmetric and Asymmetric B...Performance Evaluation of G+5, G+10 and G+15 Story Symmetric and Asymmetric B...
Performance Evaluation of G+5, G+10 and G+15 Story Symmetric and Asymmetric B...
 

Kürzlich hochgeladen

How to convert PDF to text with Nanonets
How to convert PDF to text with NanonetsHow to convert PDF to text with Nanonets
How to convert PDF to text with Nanonetsnaman860154
 
Factors to Consider When Choosing Accounts Payable Services Providers.pptx
Factors to Consider When Choosing Accounts Payable Services Providers.pptxFactors to Consider When Choosing Accounts Payable Services Providers.pptx
Factors to Consider When Choosing Accounts Payable Services Providers.pptxKatpro Technologies
 
🐬 The future of MySQL is Postgres 🐘
🐬  The future of MySQL is Postgres   🐘🐬  The future of MySQL is Postgres   🐘
🐬 The future of MySQL is Postgres 🐘RTylerCroy
 
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...apidays
 
Breaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path MountBreaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path MountPuma Security, LLC
 
Artificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and MythsArtificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and MythsJoaquim Jorge
 
Presentation on how to chat with PDF using ChatGPT code interpreter
Presentation on how to chat with PDF using ChatGPT code interpreterPresentation on how to chat with PDF using ChatGPT code interpreter
Presentation on how to chat with PDF using ChatGPT code interpreternaman860154
 
[2024]Digital Global Overview Report 2024 Meltwater.pdf
[2024]Digital Global Overview Report 2024 Meltwater.pdf[2024]Digital Global Overview Report 2024 Meltwater.pdf
[2024]Digital Global Overview Report 2024 Meltwater.pdfhans926745
 
A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)Gabriella Davis
 
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...Miguel Araújo
 
EIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptx
EIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptxEIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptx
EIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptxEarley Information Science
 
Workshop - Best of Both Worlds_ Combine KG and Vector search for enhanced R...
Workshop - Best of Both Worlds_ Combine  KG and Vector search for  enhanced R...Workshop - Best of Both Worlds_ Combine  KG and Vector search for  enhanced R...
Workshop - Best of Both Worlds_ Combine KG and Vector search for enhanced R...Neo4j
 
Understanding Discord NSFW Servers A Guide for Responsible Users.pdf
Understanding Discord NSFW Servers A Guide for Responsible Users.pdfUnderstanding Discord NSFW Servers A Guide for Responsible Users.pdf
Understanding Discord NSFW Servers A Guide for Responsible Users.pdfUK Journal
 
The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024Rafal Los
 
08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking MenDelhi Call girls
 
08448380779 Call Girls In Greater Kailash - I Women Seeking Men
08448380779 Call Girls In Greater Kailash - I Women Seeking Men08448380779 Call Girls In Greater Kailash - I Women Seeking Men
08448380779 Call Girls In Greater Kailash - I Women Seeking MenDelhi Call girls
 
Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...Enterprise Knowledge
 
CNv6 Instructor Chapter 6 Quality of Service
CNv6 Instructor Chapter 6 Quality of ServiceCNv6 Instructor Chapter 6 Quality of Service
CNv6 Instructor Chapter 6 Quality of Servicegiselly40
 
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationFrom Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationSafe Software
 
Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024The Digital Insurer
 

Kürzlich hochgeladen (20)

How to convert PDF to text with Nanonets
How to convert PDF to text with NanonetsHow to convert PDF to text with Nanonets
How to convert PDF to text with Nanonets
 
Factors to Consider When Choosing Accounts Payable Services Providers.pptx
Factors to Consider When Choosing Accounts Payable Services Providers.pptxFactors to Consider When Choosing Accounts Payable Services Providers.pptx
Factors to Consider When Choosing Accounts Payable Services Providers.pptx
 
🐬 The future of MySQL is Postgres 🐘
🐬  The future of MySQL is Postgres   🐘🐬  The future of MySQL is Postgres   🐘
🐬 The future of MySQL is Postgres 🐘
 
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
 
Breaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path MountBreaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path Mount
 
Artificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and MythsArtificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and Myths
 
Presentation on how to chat with PDF using ChatGPT code interpreter
Presentation on how to chat with PDF using ChatGPT code interpreterPresentation on how to chat with PDF using ChatGPT code interpreter
Presentation on how to chat with PDF using ChatGPT code interpreter
 
[2024]Digital Global Overview Report 2024 Meltwater.pdf
[2024]Digital Global Overview Report 2024 Meltwater.pdf[2024]Digital Global Overview Report 2024 Meltwater.pdf
[2024]Digital Global Overview Report 2024 Meltwater.pdf
 
A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)
 
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
Mastering MySQL Database Architecture: Deep Dive into MySQL Shell and MySQL R...
 
EIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptx
EIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptxEIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptx
EIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptx
 
Workshop - Best of Both Worlds_ Combine KG and Vector search for enhanced R...
Workshop - Best of Both Worlds_ Combine  KG and Vector search for  enhanced R...Workshop - Best of Both Worlds_ Combine  KG and Vector search for  enhanced R...
Workshop - Best of Both Worlds_ Combine KG and Vector search for enhanced R...
 
Understanding Discord NSFW Servers A Guide for Responsible Users.pdf
Understanding Discord NSFW Servers A Guide for Responsible Users.pdfUnderstanding Discord NSFW Servers A Guide for Responsible Users.pdf
Understanding Discord NSFW Servers A Guide for Responsible Users.pdf
 
The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024
 
08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men
 
08448380779 Call Girls In Greater Kailash - I Women Seeking Men
08448380779 Call Girls In Greater Kailash - I Women Seeking Men08448380779 Call Girls In Greater Kailash - I Women Seeking Men
08448380779 Call Girls In Greater Kailash - I Women Seeking Men
 
Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...
 
CNv6 Instructor Chapter 6 Quality of Service
CNv6 Instructor Chapter 6 Quality of ServiceCNv6 Instructor Chapter 6 Quality of Service
CNv6 Instructor Chapter 6 Quality of Service
 
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationFrom Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
 
Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024
 

Non linear static analysis aist petti_marino

  • 1. University of Salerno Department of Civil Engineering Contact Person: Luigi Petti, petti@unisa.it REPORT INNOVATIVE PROCEDURES TO ASSESS SEISMIC BEHAVIOUR OF EXISTING STRUCTURES BY MEANS OF NON LINEAR STATIC ANALYSIS: POLAR SPECTRUM & CAPACITY DOMAINS Luigi Petti, Ivana Marino INTRODUCTION As known, the standard analysis for traditional seismic design is Linear Dynamic Procedure (LDP) with assigned response spectrum (Response Spectrum Analysis). More complex procedures, such as non-linear time history analysis (NDP), are seldom used because of the difficulties in the definition of an accurate hysteretic model to describe the behaviour of the materials under cyclic actions and the choice of a set of accelerograms that describes the real site conditions. Moreover, as it is well-known, NDP analyses present convergence difficulties and require major computational effort. Non-linear static analysis is instead becoming the key method to evaluate the seismic response of existing structures. This method, which is able to evaluate the collapse mechanism of structures, is suitable for the analysis of structures not explicitly designed for seismic actions. However, non-linear static procedures can lead to unsuitable results when applied to irregular structures because of the difficulties in taking into account dynamic latero- torsional effects. As it is known, an asymmetric distribution of mass and stiffness, or of strength in plan, leads to high ductility demand for the elements near the soft or weak edge. In the last years, several proposals have been put forward to extend traditional pushover analysis, calibrated on plan systems, to the assessment of three-dimensional models behaviour. At present no simplified procedure which can adequately account for the torsional behaviour of asymmetric structures is implemented. The main questions concern the combination of the forces in the two directions, and the best way to consider extra ductility demand for the elements near the edges. This report presents and discusses the main results of the new methodology to assess the seismic response of irregular structures by means of capacity domains which allow us to evaluate the direction of least seismic capacity of the investigated buildings and polar spectrum which representing the seismic demand in plan. In particular, the capacity domains, represented in terms of strength and displacement capacities, are evaluated using traditional pushover analyses by applying load distributions, triangular and uniform, at different angles in plan to search for the least seismic - resistant direction. The polar 1
  • 2. spectrum, instead, is a new spectral representation which are able to investigate the seismic demand each in-plane direction. In particular, this tool is based on the spatial spectral surface obtained by the spectral seismic response evaluated for different in-plan directions and the in-plan projection is defined “Polar Spectrum”. Both polar spectrum and capacity domains allow researchers to investigate the non-linear seismic capacities of irregular structures. As is well-known, indeed, the collapse conditions for a three-dimensional system are also governed by the spatial features of the seismic event. Therefore, the goal of the presented results is to investigate the seismic behaviour of irregular structures by considering the least seismic-resistant directions of the investigated structure and the spatial features of the seismic event. DESCRIPTION OF THE BENCHMARK STRUCTURE To the scope of this report the benchmark structure proposed in the ReLUIS project (Rete dei Laboratori Universitari di Ingegneria Sismica – Earthquake Engineering Test Labs Network) is considered. The structure, designed without seismic actions, is a five-storey L-shaped building with RC moment frames in two orthogonal directions, as represented in Figure 1. Details of the benchmark structure are contained in the ReLUIS project. Y e d c b a X 1 2 3 4 5 Fig. 1 – Benchmark Structure Plan A finite-element model has been implemented in Opensees software. The floors are modelled by means of 50mm elastic shells and the elastic modulus is set to the value of 30000MPa. Beams and columns are modelled by spread plasticity non-linear elements with fiber sections applied. The collapse condition for the generic section is defined in terms of section curvature, evaluated by imposing limit strain values for the concrete fibers (c=0,006 in compression) and for the reinforced steel fibers (s=0,03 in tension). The main dynamical properties of the model are reported in the Table 1. In particular, each mode shape is described by the vibration period (T), the mass participation ratios (M%) and the sum of the participation ratios up to the considered modal shape (SUM). 2
  • 3. Modo T(s) M%x M%y SumX SumY 1 1,35 10,9% 52,1% 10,9% 52,1% 2 1,22 56,9% 19,6% 67,8% 71,8% 3 0,99 10,8% 9,2% 78,6% 80,9% 4 0,42 0,9% 8,5% 79,4% 89,4% 5 0,38 9,4% 1,9% 88,8% 91,2% 6 0,31 1,5% 1,1% 90,3% 92,4% 7 0,23 0,1% 4,1% 90,4% 96,5% 8 0,20 4,2% 0,5% 94,6% 97,0% 9 0,17 0,9% 0,5% 95,5% 97,5% Table 1 - Modal properties for the Benchmark Structure THE CONCEPT OF THE CAPACITY DOMAINS In order to assess the non-linear static response of irregular structures it is possible to obtain capacity domains, in terms of control node displacement or base shear. In particular, such domains are obtained from the results of non-linear static procedures (pushover) carried out by varying the in-plan direction of the applied load distribution. The domains, represented in the following, depict the displacement of the control node or the base shear up to collapse. The analyses are carried out by applying two load distributions along the height of the structure. The first one is a triangular distribution, taking into consideration the inertial masses and the height above the ground. The second one considers only the floor masses. The forces are applied at beam-column joints, proportionally to the joints mass. For each applied load distribution, 24 capacity curves have been obtained by rotating the direction of action in the x-y plane, 15° at each step. The control node is assumed to be the centre of mass on the top floor in all the pushover analyses carried out. Using the described limit values for section curvature, the global collapse is assumed when the first primary element exceeds its limit. Each pushover curve is bi-linearized according to the FEMA 356 procedure. The capacity domains are compared to the non-linear dynamic response to recorded earthquake, selected among those proposed by ReLUIS. The records, considering both NS and EW components, are suitably scaled to study the structural response by varying ground acceleration as in the case of non linear incremental analysis (IDA). The main results are represented in the following. In particular, the figures 2 and 3refer to the collapse of the analyzed benchmark structure by varying the direction of action in the plan in the case of triangular (TR) and uniform (UN) load distributions and represent the capacity domains. These domains are plotted in terms of displacement of the control node (U) and shear base (Vb). As it is possible to observe for both domains a non-regular behaviour of the structure above all in terms of limit displacements. In particular, the analyses show that the benchmark structure presents lower displacement capacities in the 150°- 330° direction. Otherwise, structural behaviour seems to be more regular in terms of strength. 3
  • 4. U (cm) Vb (kN) 90 90 105 20 75 105 3000 75 120 60 120 60 2500 135 15 45 135 45 2000 150 10 30 150 1500 30 1000 165 15 165 15 5 500 180 0 0 180 0 0 195 345 195 345 210 330 210 330 225 315 225 315 240 300 UN 240 300 255 285 UN TR 255 285 270 270 TR Fig. 2 - Capacity Domains in terms of node control Fig. 3 - Capacity Domains in terms of base shear displacements at collapse In order to evaluate the applicability of the capacity domains to accurately describe the collapse state of a structure, incremental dynamic analyses have been performed. For both the considered in-plan dispositions of the structures, 0° and 90°, the analyses have been carried out considering the Iceland 2000 earthquake (code 06334, maximum PGA equal to 7,07m/s2). The figures 4-7 show the dynamic response (NDP) for the analyzed cases. 0,2 3000 0,15 2000 0,1 1000 0,05 Uy (m) Vy (kN) 0 0 -0,2 -0,15 -0,1 -0,05 0 0,05 0,1 0,15 0,2 -3000 -2000 -1000 0 1000 2000 3000 -0,05 -1000 -0,1 -2000 -0,15 -0,2 -3000 Ux (m) Vx (kN) NSP uniform NSP Triangular NDP NSP uniform NSP Triangular NDP Fig. 4 – Comparition between capacity domains and Fig. 5 - Comparition between capacitys domain and NDP - Collapse amplification factor 0.40 - In plan NDP - Collapse amplification factor 0.40 - In plan orientation of benchmark structure 0° orientation of benchmark structure 0° 4
  • 5. 0,20 3000 0,15 2000 0,10 1000 0,05 Uy (m) Vy (kN) 0,00 0 -0,20 -0,15 -0,10 -0,05 0,00 0,05 0,10 0,15 0,20 -3000 -2000 -1000 0 1000 2000 3000 -0,05 -1000 -0,10 -2000 -0,15 -0,20 -3000 Ux (m) Vx (kN) NSP uniform NSP Triangular NDP NSP uniform NSP Triangular NDP Fig. 6 – Comparition between capacity domains and Fig. 7 - Comparition between capacity domains and NDP - Collapse amplification factor 0.35 - In plan NDP - Collapse amplification factor 0.35- In plan orientation of benchmark structure 90° orientation of benchmark structure 90° As it is possible to observe, the collapse is attained in the direction of about 255° independently by plan orientation of benchmark structure. Moreover, the collapse occurs in correspondence of the capacity domain for triangular load distribution, and the collapsed element, column 15 at ground level, is the same for both dynamic and static analyses. For both analyses the collapse amplification factor in the case of NDP is represented. In the figures, the capacity domains are indicated with NSP (Non-linear Static Procedure) for the uniform and triangular load distributions. As a further comparison between static and dynamic responses, figure 8 shows storey displacements at collapse for both analyses in the considered plan directions of benchmark structure (0° and 90°). 5 5 4 4 3 3 imp imp 2 2 1 1 0 0 0 0,1 0,2 0 0,1 0,2 U (m) U (m) NSP uniform NSP Triangular NDP Fig. 8 – Storey Displacement Comparison at collapse for in plan directions 0° and 90° 5
  • 6. Results show that the collapse mechanism is a global one, being the displacement path carried out by NDP well described by the one obtained by NSP with triangular load distribution. Moreover, as it is possible to observe, the collapse as well as read with NDP procedure intercepts always the capacity domains corresponding to triangular load distribution (outer domain in figures 4 and 6 and inner domain in figures 5 and 7). THE CONCEPT OF “POLAR SPECTRUM” As known, seismic events generally present a strong directivity effects due to site geo- morphological conditions, source mechanism and path from source to the site of the seismic waves. To take into account the directivity and site effects it is possible to refer to polar spectrum, a new tool, proposed by authors, which is able to investigate each in-plan direction. In particular, this tool is based on the spatial spectral surface obtained by the spectral seismic response evaluated for different in-plan directions and the in-plan projection of this surface is defined “Polar Spectrum”. Figure 9 shows the polar spectrum in terms of pseudo-acceleration for the seismic event South Iceland aftershock (code 006334) with a damping factor =0,05 in the range of periods 0-2 seconds. In particular, the spectral surface has been obtained by considering the NS and EW components of recorded accelerograms projected along each direction in plan. In correspondence of each radius, the spectrum response evaluated in that direction is represented. In correspondence to each circumference, instead, the spectral demand for a fixed period is plotted for each considered direction. The origin corresponds to 0 sec period. As it is easy to observe, the polar spectrum is a polar-symmetric figure. Fig. 9 – Polar Spectrum in terms of pseudo-acceleration for South Iceland aftershock (code 006334) The analysis of polar spectrum shows that the considered seismic event presents a peak demand along the direction (75°-255°) regardless of the vibration period value. The comparison between the polar spectrum of the considered seismic event and the results of Non-Linear Dynamic Procedure (NDP) shows clearly as the collapse of the benchmark structure are controlled by the directivity effects more than seismic capacity of the analyzed structure. “CRITICAL” ALIGNMENT The possibility of evaluating the worst structural response moving from observation of the polar spectrum suggests performing dynamic analyses with the structure oriented so that its 6
  • 7. least capacity direction (assessed by means of the capacity domains) is aligned with the maximum seismic demand (evaluated by means of the polar spectrum). Figure 10 depicts the results in this case. In particular, the structure is been rotated 105° counter-clockwise in order to match the least resistant direction (=150°- 330°) with the maximum spectral seismic demand direction (75°- 255°). 0,20 0,15 0,10 0,05 Uy (m) 0,00 -0,20 -0,15 -0,10 -0,05 0,00 0,05 0,10 0,15 0,20 -0,05 -0,10 -0,15 -0,20 Ux (m) Fig. 10 – Dynamic analyses results, in plan orientation of the benchmark structure 240°, NDP collapse amplification factor 0.30 The obtained results show that when the least seismic resistance direction is aligned with the maximum seismic demand, the minimum collapse amplification factor is reached. SOFTWARE IMPLEMENTATION A first implementation of the capacity domains could be found in the software IPERSPACE which leads to evaluate these domains in terms of limit states according to the Italian Design Code (NTC 2008). As an example, the following figures represent the main results obtained with Iperspace software for the analyzed benchmark structure: Fig.11- Capacity Domains in terms of node control displacements at collapse (on the left) and maximum base shear (on the right) obtained with Iperspace Software 7
  • 8. The modest difference between the capacity domains obtained by Iperspace and by Opensees is due to the adopted collapse criteria. In the case of Iperspace, the NTC2008 collapse criterion has been considered by controlling the ultimate plastic hinge rotation of RC members. CONCLUDING REMARKS The report shows new tools in order to assess the non-linear behaviour of a irregular building and the spectral seismic demand in plan. In particular, the capacity domains are evaluated by means of pushover analyses by varying the load distribution in plan and lead to search for less seismic resistant directions. The polar spectra lead to a fully assessment of the spatial features of the seismic demand and represent an opportunity to investigate thoroughly the seismic demand and the event characteristics, being able to clearly evaluate directivity and site effects. From the obtained results it is possible to observe that:  The collapse condition, assessed by means of non-linear dynamic procedures, turns out to be coherent with the capacity domains based on the results of traditional non-linear static procedures carried out by varying the angle of the application of the load distribution;  The non-linear dynamic analyses have shown that the directional components of the seismic event govern the collapse direction;  The worst condition for a structure is obtained by aligning its least resistance capacity direction, evaluated on the basis of the capacity domains, with the maximum response demand direction identified by the polar spectrum. REFERENCES Ayala A. G. and Tavera, E. A. [2002], “A new approach for the evaluation of the seismic performance of asymmetric buildings”, Proc. of the 7th National Conference on Earthquake Engineering, Boston. Chopra A. K. and Goel, R. K. [2004], “A modal pushover analysis procedure to estimate seismic demands for unsymmetric-plan buildings”, Earthquake Engineering and Structural Dynamics 33(8), pp. 903-927. Chopra A. K. [2008]. Application of modal pushover analysis to RC frames and Incremental Dynamic Analysis. Nonlinear Static Methods for Design/Assessment of 3D Structures, 5-6 May 2008, Lisbon, Portugal. Faella G. and Kilar V. [1998], “Asymmetric multistory R/C frame structures: push-over versus nonlinear dynamic analysis”, Proc., 11th Eur. Conf. Earth. Engrg., A.A. Balkema, Rotterdam. Fajfar P. [2000], “A nonlinear analysis method for performance-based seismic design”, Earthquake Spectra 16(3), pp. 573-592. Fajfar, P. [2002], “Structural analysis in earthquake engineering - a breakthrough of simplified nonlinear methods”, Proc. of the 12th European Conference on Earthquake Engineering, London, UK, Keynote lecture. Fajfar P. and Gaspersic P. [1996], “The N2 method for the seismic damage analysis of RC buildings”, Earthquake Engineering and Structural Dynamics 25, pp. 23-67. 8
  • 9. Fajfar P. and Kilar V. [1997], “Simple push-over analysis of asymmetric buildings”, Earthquake Engineering and Structural Dynamics, Vol. 26, pp. 233-249. Fajfar P., Kilar V., Marusic D., Perus I. and Magliulo G. [2002], “The extension of the N2 method to asymmetric buildings”, Proc. of the fourth forum on Implications of recent earthquakes on seismic risk, Technical report TIT/EERG, 02/1, Tokyo Institute of Technology, Tokyo, pp. 291- 308. Fajfar P., Marusic D. and Perus I. [2004], “Influence of ground motion intensity on the inelastic torsional response of asymmetric buildings”, Proc. of the 13th World Conference on Earthquake Engineering, Vancouver, Canada, Paper No. 3496. Fajfar P., Marusic D. and Perus I. [2005], “Torsional effects in the pushover-based seismic analysis of buildings”, Journal of Earthquake Engineering, Vol. 9, No. 6, pp. 831-854. Fajfar P., Marusic D., Perus I., Kreslin M. [2008]. “The N2 method for asymmetric buildings”, Nonlinear Static Methods for Design/Assessment of 3D Structures, 5-6 May 2008, Lisbon, Portugal. Fujii K., Nakano Y. and Sanada Y. [2004], “Simplified nonlinear analysis procedure for asymmetric buildings”, Proc. of the 13th World Conference on Earthquake Engineering, Vancouver, Canada, Paper No. 149. Goel R. K. [2008] Generalized pushover curves for nonlinear static analysis of three dimensional structures. Nonlinear Static Methods for Design/Assessment of 3D Structures, 5-6 May 2008, Lisbon, Portugal. Hejal R. and Chopra A. [1987], “Earthquake response of torsionally-coupled buildings”, Report UCB/EERC-87/20. Kan C. L. and Chopra A. K. [1979], “Linear and nonlinear earthquake responses of simple torsionally coupled systems”, Report UCB/EERC-79/03. Kilar V. and Fajfar P. [2001], “On the applicability of pushover analysis to the seismic performance evaluation of asymmetric buildings”, European Earthquake Engineering 15, pp. 20- 31. Marino I., Petti L. [2011], “Seismic Assessment of Asymmetric Structures Behaviour by using Static Non-Linear Analysis”, in corso di stampa sulla rivista Journal of Civil Engineering and Architecture ISSN 1934-7359. Moghadam A. S. and Tso K. [2000], “Pushover analysis for asymmetric and set-back multistory buildings”, Proc. of the 12th World Conference on Earthquake Engineering, Auckland, New Zealand, Paper No. 1093. Open System for Earthquake Engineering Simulation (OpenSEES), Pacific Earthquake Engineering Research Center, University of California, Berkley (USA); Petti L., Marino I., Cuoco L., Palazzo B. [2008], “Assessment of Seismic Response of Plan- Asymmetric Structures through simplified Static Nonlinear Analyses”, Proc.the 14th World Conference on Earthquake Engineeering, Beijing, China. Pettinga J. D., Priestley M. J. N., Pampanin S., Christopulos C. [2007], “The Role of Inelastic Torsion in the Determination of Residual Deformations”, Journal of Earthquake Engineering, vo.l 11 2007, supplement 1, Proceedings of the Sixth ROSE Seminar. ReLUIS project - Rete dei Laboratori Universitari di Ingegneria Sismica – Earthquake Engineering Test Labs Network, www.reluis.unina.it. Reyes C. Juan and Anil K. Chopra [2011], “Evaluation of three-dimensional modal pushover analysis for unsymmetric-plan buildings subjected to two components of ground motion”, Earthquake Engineering and Structural Dynamics; 40:1475 -1494. 9
  • 10. Rutenberg A. [2002], EAEE Task Group (TG) 8: “Behaviour of irregular and complex structures asymmetric structures - progress since 1998”, Proc. of the 12th European Conference on Earthquake Engineering, London, UK, Paper No. 832. Rutenberg A., Levy R. and Magliulo G. [2002], “Seismic response of asymmetric perimeter frame steel buildings”, Proc. of the 12th European Conference on Earthquake Engineering, London, UK, Paper No. 107. Soft.lab, Software Partnership http://www.soft.lab.it, Via Borgo II° - 82030 - PONTE (BN) - IT, IperSpace Max Tso W. K. and Moghadam A. S. [1997], “Seismic response of asymmetrical buildings using pushover analysis”, Proc. of the International Workshop on Seismic Design Methodologies for the Next Generation of Codes, Bled, Slovenia, eds. P. Fajfar and H. Krawinkler (A.A. Balkema, Roterdam, Brookfield), pp. 311-321. Tso W. K. and Myslimaj B. [2002], “Effect of strength distribution on the inelastic torsional response of asymmetric structural systems”, Proc. of the 12th European Conference on Earthquake Engineering, London, UK, Paper No. 081. Yu Q.S.K., Pugliesi R., Allen M. and Bischoff C. [2004], “Assessment of modal pushover analysis procedure and its application to seismic evaluation of existing building”, Proc. of the 13th World Conference on Earthquake Engineering, Vancouver, Canada, Paper No. 1104. Zarate A. and Ayala A. G. [2004], “Validation of single storey models for the evaluation of seismic performance of multi-storey asymmetric buildings”, Proc. of the 13th World Conference on Earthquake Engineering, Vancouver, Canada, Paper No. 2213. 10