SlideShare ist ein Scribd-Unternehmen logo
1 von 19
FURAN ANALYSES IN TRANSFORMER
PRESENTED BY:
Nitish Kumar, Nutan Chandra, Muna Kumar,
Subhajit Bhandari .
Guided By: Er. A Kannan
Dr. M.G.R. University
EEE Department
SCOPE
 Analysis the 2-furtural and related furan
compounds during cellulosic insulation in mineral
insulating oil samples.
 analyzed by high performance liquid
chromatography
(HPCL)
furan derivatives are extracted from the oil by use
of a extraction method such as liquid-liquid
extraction (method A) or solid-phase separation
on silica cartridge (method B).
ABSTRACT:
To determine of the life of Transformer and
the condition of Insulating Component furan
test conduct.
To Study the effect of oil reconditioning and
oil replacement on the furan values.
To Study the relationship between carbon die
- oxide and furan compounds in power
Transformers.
Introduction:
The insulating system of a transformer consist of both
paper and oil.
A transformer reaches the end of its life when its
insulation system totally lost its dielectric properties.
Moisture is introduce into the system, and particle
accumulate in the oil.
As the paper insulation ages, tensile strength decreases,
making the unit susceptible to winding failure during
mechanical stresses such as vibration, through faults and
short circuit.
Degradation of cellulosic materials produces CO and
CO2 gases. These gases dissolve in oil, by extracting these
gases and analyzing them, the paper insulation
degradation can be assessed.
Construction of Transformer
Definition of Transformer:
Electrical Power Transformer is a static device which transforms power from on circuit to
another without changing its frequency but may be in different voltage level.
Industrial transformer parts:
 Frame, enclosure, tank
 De-energized tap changer
 Dual-voltage switch
 Windings
 Core
 Control relays
 Cooling fans
 Pressure-relief Valve
 Air terminal chambers
 Nameplate or label
Production of Transformer oil
Transformer oil is hydrocarbon product,
mainly oil contains napthanic, parrafinic and
aromatics.
crude oil which is buried from earth crust.
Clay treatment process on TOBS will give us the
finished transformer oil.
After the hot filtration operation transformer oil
is ready for filling the transformers.
Types of Transformer Oil
Generally there are two types of Transformer Oil used in transformer
1. Paraffin based Transformer Oil
2. Naphtha based Transformer Oil
Naphtha oil is more easily oxidized than Paraffin oil. Paraffin based oil obstruct
the transformer cooling system. Although it has mentioned disadvantage but still
in our country it is generally used because of its easy availability.
Various Type Of Oil Based On Colour
Type of test conducted on
Transformer oil
Dissolved Gas Analyzer test
Break Down Voltage Test
Tan Delta & Resistivity Test
Total Acidity Test
Water Content Test
Inter Facial Tension Test
Furan Compounds Test.
WHAT IS FURAN?
Furan is a hetero cyclic aromatic system consisting of 4 carbon
and one oxygen in a five membered ring
Molecular formula is C4H4O
Structure of Furan Components
Insulation Paper
Evaluation through DP
Degree of Polymerization (DP): A
measure of length of cellulose chains
Value for fresh paper: 1000-1200
Value at End of life: 150-200
Paper Insulation
Mechanism of Degradation
 Degradation is accelerated by temperature,
water and oxygen
Degradation by-products are:
Water and Carbon oxides
Furans
Alcohols, acids and aromatic & aliphatic
hydrocarbons
INSTRUMENTATION
FLOW DIAGRAM OF HPLC
INSTRUMENTATION
CASE STUDY THROUGH SAMPLING OILS
Case no :1 FOR LOW LEVEL PPB
0
5
10
15
20
25
30
35
40
45
5HMFL 2-FA 2-FO 2-AF 5-M2FAL TOTAL
Transformer 1
Transformer 2
Transformer 3
Transformer 4
0
200
400
600
800
1000
1200
1400
5HMFL 2-FA 2-FO 2-AF 5-M2FAL TOTAL
Transformer 1
Transformer 2
Transformer3
Transformer 4
Transformer 5
Transformer 6
Transformer 7
Transformer 8
Transformer 9
Transformer 10
Transformer 11
Transformer 12
Column1
Column2
Transformer 15
CASE NO:2 MEDIUM LEVEL PPB
CASE NO:3 HIGH LEVEL PPB
0
2000
4000
6000
8000
10000
12000
14000
5HMFL 2-FA 2-FO 2-AF 5-M2FAL TOTAL
Transformer 1
Transformer 2
Transformer 3
Transformer 4
Transfoermer 5
Transformer 6
Transformer7
Transformer 8
Transformer 9
Conclusion:
REWIND / REPLACE SOLID INSULATION
This value are above shown data is available IEEE
In INDIA value are under study conducted by CPRI
State of Transformer Oil Standard Value of PPB
Normal 0 – 100
Questionable 101 – 250
Deteriorated 251 – 1000
Low Reliability 1001.– 2500
Rewind / Replace Solid Insulation >2500
The oil treatment is needed for keeping the transformer on
good technical condition & helps to make better the solid and
liquid insulation parameters.
18 & 19 March 2011 ICCCET 2011 - National College of Engineering 20

Weitere ähnliche Inhalte

Was ist angesagt?

Presentation_Power_Transformers-1
Presentation_Power_Transformers-1Presentation_Power_Transformers-1
Presentation_Power_Transformers-1
Nageswar Rao
 

Was ist angesagt? (20)

Transformer oil-specifications new
Transformer oil-specifications newTransformer oil-specifications new
Transformer oil-specifications new
 
Electrical HT/LT Motor protection
Electrical HT/LT Motor protectionElectrical HT/LT Motor protection
Electrical HT/LT Motor protection
 
Testing of Transformers.
Testing of Transformers.Testing of Transformers.
Testing of Transformers.
 
Oil circuit breakers
Oil circuit breakersOil circuit breakers
Oil circuit breakers
 
Presentation_Power_Transformers-1
Presentation_Power_Transformers-1Presentation_Power_Transformers-1
Presentation_Power_Transformers-1
 
Transformer testing on sight and off sight
Transformer testing on sight and off sightTransformer testing on sight and off sight
Transformer testing on sight and off sight
 
Transformer
TransformerTransformer
Transformer
 
DGA
DGADGA
DGA
 
Under ground cables presention
Under ground cables presentionUnder ground cables presention
Under ground cables presention
 
Ppt on protection of power transformers
Ppt on protection of power transformersPpt on protection of power transformers
Ppt on protection of power transformers
 
Testing,maintenance&protection
Testing,maintenance&protectionTesting,maintenance&protection
Testing,maintenance&protection
 
TRANSFORMER TEST acceptance criteria
TRANSFORMER TEST acceptance criteriaTRANSFORMER TEST acceptance criteria
TRANSFORMER TEST acceptance criteria
 
Transformer Maintenance
Transformer Maintenance Transformer Maintenance
Transformer Maintenance
 
Cable and laying
Cable and layingCable and laying
Cable and laying
 
RTCC & AVR
RTCC & AVRRTCC & AVR
RTCC & AVR
 
Circuit Breaker : Types
Circuit Breaker : TypesCircuit Breaker : Types
Circuit Breaker : Types
 
Testing of transformer
Testing of transformerTesting of transformer
Testing of transformer
 
Oil circuit breaker
Oil circuit breakerOil circuit breaker
Oil circuit breaker
 
Vacuum circuit breaker
Vacuum circuit breakerVacuum circuit breaker
Vacuum circuit breaker
 
Power Transformer Parts And Functions
Power Transformer Parts And FunctionsPower Transformer Parts And Functions
Power Transformer Parts And Functions
 

Ähnlich wie Furan Testing of Transformers Oil

Desalination of Sea Water using Membrane technology
 Desalination of Sea Water using Membrane technology Desalination of Sea Water using Membrane technology
Desalination of Sea Water using Membrane technology
Chandni Sinha
 
Palm Oil As An Alternative Dielectric Transformer Coolant
Palm Oil As An Alternative Dielectric Transformer CoolantPalm Oil As An Alternative Dielectric Transformer Coolant
Palm Oil As An Alternative Dielectric Transformer Coolant
IJRES Journal
 
01 Overview of Power transformers - Remedial Measures.ppt
01 Overview of Power transformers - Remedial Measures.ppt01 Overview of Power transformers - Remedial Measures.ppt
01 Overview of Power transformers - Remedial Measures.ppt
vikram desai
 
The study and modeling of organic rankine cycle
The study and modeling of organic rankine cycleThe study and modeling of organic rankine cycle
The study and modeling of organic rankine cycle
Sulaiman Dawood Barry
 
PRESENTATION ON INPLANT TRAINING AT MRPL
PRESENTATION ON INPLANT TRAINING AT MRPLPRESENTATION ON INPLANT TRAINING AT MRPL
PRESENTATION ON INPLANT TRAINING AT MRPL
Ankit Devatwal
 
UREA 1 REPORT TO A K SAXENA SIR
UREA 1 REPORT TO A K SAXENA SIRUREA 1 REPORT TO A K SAXENA SIR
UREA 1 REPORT TO A K SAXENA SIR
DESHRAJ MEENA
 

Ähnlich wie Furan Testing of Transformers Oil (20)

Transformer oil
Transformer oilTransformer oil
Transformer oil
 
A case study on Process Condensate Stripper in Ammonia Plant by Prem Baboo.pdf
A case study on Process Condensate Stripper in Ammonia Plant by Prem Baboo.pdfA case study on Process Condensate Stripper in Ammonia Plant by Prem Baboo.pdf
A case study on Process Condensate Stripper in Ammonia Plant by Prem Baboo.pdf
 
Desalination of Sea Water using Membrane technology
 Desalination of Sea Water using Membrane technology Desalination of Sea Water using Membrane technology
Desalination of Sea Water using Membrane technology
 
Palm Oil As An Alternative Dielectric Transformer Coolant
Palm Oil As An Alternative Dielectric Transformer CoolantPalm Oil As An Alternative Dielectric Transformer Coolant
Palm Oil As An Alternative Dielectric Transformer Coolant
 
01 Overview of Power transformers - Remedial Measures.ppt
01 Overview of Power transformers - Remedial Measures.ppt01 Overview of Power transformers - Remedial Measures.ppt
01 Overview of Power transformers - Remedial Measures.ppt
 
The study and modeling of organic rankine cycle
The study and modeling of organic rankine cycleThe study and modeling of organic rankine cycle
The study and modeling of organic rankine cycle
 
5.pdf
5.pdf5.pdf
5.pdf
 
Methanol Flowsheets - A Competitive Review
Methanol Flowsheets - A Competitive ReviewMethanol Flowsheets - A Competitive Review
Methanol Flowsheets - A Competitive Review
 
Pre HMW PE Trial
Pre HMW PE TrialPre HMW PE Trial
Pre HMW PE Trial
 
Packed Bed Reactor for Catalytic Cracking of Plasma Pyrolyzed Gas
Packed Bed Reactor for Catalytic Cracking of Plasma Pyrolyzed GasPacked Bed Reactor for Catalytic Cracking of Plasma Pyrolyzed Gas
Packed Bed Reactor for Catalytic Cracking of Plasma Pyrolyzed Gas
 
PRESENTATION ON INPLANT TRAINING AT MRPL
PRESENTATION ON INPLANT TRAINING AT MRPLPRESENTATION ON INPLANT TRAINING AT MRPL
PRESENTATION ON INPLANT TRAINING AT MRPL
 
IRJET- Development of a New Solid Insulation paper with the use of Phenol For...
IRJET- Development of a New Solid Insulation paper with the use of Phenol For...IRJET- Development of a New Solid Insulation paper with the use of Phenol For...
IRJET- Development of a New Solid Insulation paper with the use of Phenol For...
 
UREA 1 REPORT TO A K SAXENA SIR
UREA 1 REPORT TO A K SAXENA SIRUREA 1 REPORT TO A K SAXENA SIR
UREA 1 REPORT TO A K SAXENA SIR
 
Transformer Repair Workshop Report [EEE]
Transformer Repair Workshop Report [EEE] Transformer Repair Workshop Report [EEE]
Transformer Repair Workshop Report [EEE]
 
H010514852
H010514852H010514852
H010514852
 
Mfed technology linked in 6-17-15
Mfed technology   linked in  6-17-15Mfed technology   linked in  6-17-15
Mfed technology linked in 6-17-15
 
transformers.ppt
transformers.ppttransformers.ppt
transformers.ppt
 
2 ijaems sept-2015-2-experimental investigation of waste transformer oil as a...
2 ijaems sept-2015-2-experimental investigation of waste transformer oil as a...2 ijaems sept-2015-2-experimental investigation of waste transformer oil as a...
2 ijaems sept-2015-2-experimental investigation of waste transformer oil as a...
 
Ijetr012053
Ijetr012053Ijetr012053
Ijetr012053
 
Chapter 2 breakdown in liquids
Chapter 2 breakdown in liquidsChapter 2 breakdown in liquids
Chapter 2 breakdown in liquids
 

Kürzlich hochgeladen

Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak HamilCara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Kandungan 087776558899
 
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
dollysharma2066
 
Call Girls in Netaji Nagar, Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
Call Girls in Netaji Nagar, Delhi 💯 Call Us 🔝9953056974 🔝 Escort ServiceCall Girls in Netaji Nagar, Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
Call Girls in Netaji Nagar, Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
9953056974 Low Rate Call Girls In Saket, Delhi NCR
 
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar ≼🔝 Delhi door step de...
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar  ≼🔝 Delhi door step de...Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar  ≼🔝 Delhi door step de...
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar ≼🔝 Delhi door step de...
9953056974 Low Rate Call Girls In Saket, Delhi NCR
 
Integrated Test Rig For HTFE-25 - Neometrix
Integrated Test Rig For HTFE-25 - NeometrixIntegrated Test Rig For HTFE-25 - Neometrix
Integrated Test Rig For HTFE-25 - Neometrix
Neometrix_Engineering_Pvt_Ltd
 
notes on Evolution Of Analytic Scalability.ppt
notes on Evolution Of Analytic Scalability.pptnotes on Evolution Of Analytic Scalability.ppt
notes on Evolution Of Analytic Scalability.ppt
MsecMca
 

Kürzlich hochgeladen (20)

Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
 
Double Revolving field theory-how the rotor develops torque
Double Revolving field theory-how the rotor develops torqueDouble Revolving field theory-how the rotor develops torque
Double Revolving field theory-how the rotor develops torque
 
Unit 2- Effective stress & Permeability.pdf
Unit 2- Effective stress & Permeability.pdfUnit 2- Effective stress & Permeability.pdf
Unit 2- Effective stress & Permeability.pdf
 
UNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its PerformanceUNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its Performance
 
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak HamilCara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
 
Water Industry Process Automation & Control Monthly - April 2024
Water Industry Process Automation & Control Monthly - April 2024Water Industry Process Automation & Control Monthly - April 2024
Water Industry Process Automation & Control Monthly - April 2024
 
COST-EFFETIVE and Energy Efficient BUILDINGS ptx
COST-EFFETIVE  and Energy Efficient BUILDINGS ptxCOST-EFFETIVE  and Energy Efficient BUILDINGS ptx
COST-EFFETIVE and Energy Efficient BUILDINGS ptx
 
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
 
Call Girls in Netaji Nagar, Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
Call Girls in Netaji Nagar, Delhi 💯 Call Us 🔝9953056974 🔝 Escort ServiceCall Girls in Netaji Nagar, Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
Call Girls in Netaji Nagar, Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
 
Thermal Engineering Unit - I & II . ppt
Thermal Engineering  Unit - I & II . pptThermal Engineering  Unit - I & II . ppt
Thermal Engineering Unit - I & II . ppt
 
Thermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.pptThermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.ppt
 
A Study of Urban Area Plan for Pabna Municipality
A Study of Urban Area Plan for Pabna MunicipalityA Study of Urban Area Plan for Pabna Municipality
A Study of Urban Area Plan for Pabna Municipality
 
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar ≼🔝 Delhi door step de...
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar  ≼🔝 Delhi door step de...Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar  ≼🔝 Delhi door step de...
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar ≼🔝 Delhi door step de...
 
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
 
Bhosari ( Call Girls ) Pune 6297143586 Hot Model With Sexy Bhabi Ready For ...
Bhosari ( Call Girls ) Pune  6297143586  Hot Model With Sexy Bhabi Ready For ...Bhosari ( Call Girls ) Pune  6297143586  Hot Model With Sexy Bhabi Ready For ...
Bhosari ( Call Girls ) Pune 6297143586 Hot Model With Sexy Bhabi Ready For ...
 
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
 
(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7
(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7
(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7
 
Hostel management system project report..pdf
Hostel management system project report..pdfHostel management system project report..pdf
Hostel management system project report..pdf
 
Integrated Test Rig For HTFE-25 - Neometrix
Integrated Test Rig For HTFE-25 - NeometrixIntegrated Test Rig For HTFE-25 - Neometrix
Integrated Test Rig For HTFE-25 - Neometrix
 
notes on Evolution Of Analytic Scalability.ppt
notes on Evolution Of Analytic Scalability.pptnotes on Evolution Of Analytic Scalability.ppt
notes on Evolution Of Analytic Scalability.ppt
 

Furan Testing of Transformers Oil

  • 1. FURAN ANALYSES IN TRANSFORMER PRESENTED BY: Nitish Kumar, Nutan Chandra, Muna Kumar, Subhajit Bhandari . Guided By: Er. A Kannan Dr. M.G.R. University EEE Department
  • 2. SCOPE  Analysis the 2-furtural and related furan compounds during cellulosic insulation in mineral insulating oil samples.  analyzed by high performance liquid chromatography (HPCL) furan derivatives are extracted from the oil by use of a extraction method such as liquid-liquid extraction (method A) or solid-phase separation on silica cartridge (method B).
  • 3. ABSTRACT: To determine of the life of Transformer and the condition of Insulating Component furan test conduct. To Study the effect of oil reconditioning and oil replacement on the furan values. To Study the relationship between carbon die - oxide and furan compounds in power Transformers.
  • 4. Introduction: The insulating system of a transformer consist of both paper and oil. A transformer reaches the end of its life when its insulation system totally lost its dielectric properties. Moisture is introduce into the system, and particle accumulate in the oil. As the paper insulation ages, tensile strength decreases, making the unit susceptible to winding failure during mechanical stresses such as vibration, through faults and short circuit. Degradation of cellulosic materials produces CO and CO2 gases. These gases dissolve in oil, by extracting these gases and analyzing them, the paper insulation degradation can be assessed.
  • 5. Construction of Transformer Definition of Transformer: Electrical Power Transformer is a static device which transforms power from on circuit to another without changing its frequency but may be in different voltage level. Industrial transformer parts:  Frame, enclosure, tank  De-energized tap changer  Dual-voltage switch  Windings  Core  Control relays  Cooling fans  Pressure-relief Valve  Air terminal chambers  Nameplate or label
  • 6. Production of Transformer oil Transformer oil is hydrocarbon product, mainly oil contains napthanic, parrafinic and aromatics. crude oil which is buried from earth crust. Clay treatment process on TOBS will give us the finished transformer oil. After the hot filtration operation transformer oil is ready for filling the transformers.
  • 7. Types of Transformer Oil Generally there are two types of Transformer Oil used in transformer 1. Paraffin based Transformer Oil 2. Naphtha based Transformer Oil Naphtha oil is more easily oxidized than Paraffin oil. Paraffin based oil obstruct the transformer cooling system. Although it has mentioned disadvantage but still in our country it is generally used because of its easy availability.
  • 8. Various Type Of Oil Based On Colour
  • 9. Type of test conducted on Transformer oil Dissolved Gas Analyzer test Break Down Voltage Test Tan Delta & Resistivity Test Total Acidity Test Water Content Test Inter Facial Tension Test Furan Compounds Test.
  • 10. WHAT IS FURAN? Furan is a hetero cyclic aromatic system consisting of 4 carbon and one oxygen in a five membered ring Molecular formula is C4H4O Structure of Furan Components
  • 11. Insulation Paper Evaluation through DP Degree of Polymerization (DP): A measure of length of cellulose chains Value for fresh paper: 1000-1200 Value at End of life: 150-200
  • 12. Paper Insulation Mechanism of Degradation  Degradation is accelerated by temperature, water and oxygen Degradation by-products are: Water and Carbon oxides Furans Alcohols, acids and aromatic & aliphatic hydrocarbons
  • 14. FLOW DIAGRAM OF HPLC INSTRUMENTATION
  • 15. CASE STUDY THROUGH SAMPLING OILS Case no :1 FOR LOW LEVEL PPB 0 5 10 15 20 25 30 35 40 45 5HMFL 2-FA 2-FO 2-AF 5-M2FAL TOTAL Transformer 1 Transformer 2 Transformer 3 Transformer 4
  • 16. 0 200 400 600 800 1000 1200 1400 5HMFL 2-FA 2-FO 2-AF 5-M2FAL TOTAL Transformer 1 Transformer 2 Transformer3 Transformer 4 Transformer 5 Transformer 6 Transformer 7 Transformer 8 Transformer 9 Transformer 10 Transformer 11 Transformer 12 Column1 Column2 Transformer 15 CASE NO:2 MEDIUM LEVEL PPB
  • 17. CASE NO:3 HIGH LEVEL PPB 0 2000 4000 6000 8000 10000 12000 14000 5HMFL 2-FA 2-FO 2-AF 5-M2FAL TOTAL Transformer 1 Transformer 2 Transformer 3 Transformer 4 Transfoermer 5 Transformer 6 Transformer7 Transformer 8 Transformer 9
  • 18. Conclusion: REWIND / REPLACE SOLID INSULATION This value are above shown data is available IEEE In INDIA value are under study conducted by CPRI State of Transformer Oil Standard Value of PPB Normal 0 – 100 Questionable 101 – 250 Deteriorated 251 – 1000 Low Reliability 1001.– 2500 Rewind / Replace Solid Insulation >2500 The oil treatment is needed for keeping the transformer on good technical condition & helps to make better the solid and liquid insulation parameters.
  • 19. 18 & 19 March 2011 ICCCET 2011 - National College of Engineering 20