1. Demonstration Thermography report
Company Testo Ltd Tester:
Cheriton House, Newman Lane Testo
Alton, Hampshire, GU34 2QJ Phone: +44(0)1420 544433
E-Mail: info@testo.co.uk
Device Testo Thermal Imaging Serial No.: various
Cameras
Lens: 32 degree, Wide Angle
Lens
Customer Testo Ltd Measuring Site:
Testo Thermal Imaging Demonstration Thermography Report
Cameras Photo Voltaic Panel Installations
Demo Report
Defective Panels
Measuring Date: Various
Task Demonstration Thermography Report to highlight the capabilities of the
Testo Thermal Imaging camera for the Detection of Thermal Anomalies in
Photo Voltaic Panels.
Page 1/8
2. Demonstration Thermography report
File: Date: Measuring Time:
IV_00115.BMT 18/05/2010 14:20:20
Picture parameters:
Emissivity: 0.94
Refl. temp. [°C]: 22.0
Picture markings:
Measurement Objects Temp. [°C] Emiss. Refl. temp. [°C] Remarks
Measure point 1 34.7 0.94 22.0 -
Measure point 2 37.0 0.94 22.0 -
Hot spot 1 51.7 0.94 22.0 -
Profile line:
Remarks:
Thermal Image of Photovoltaic Panel, highlighting Thermal Hot Spot on one of the panels.
Spot Temperature markers have been added to the thermal image to highlight comparative temperatures.
A Auto Hot Spot Indicator has been applied to the Thermal image to indicate the Hottest point within the
defined area.
A Temperature Profile Line Graph has been applied to highlight the temperature variation across the
Photovoltaic panels.
The thermal image is displayed in "Iron" palette.
Page 2/8
3. Demonstration Thermography report
File: Date: Measuring Time:
IR_00123.BMT 03/04/2009 14:55:13
Picture parameters:
Emissivity: 0.93
Refl. temp. [°C]: 8.0
Picture markings:
Measurement Objects Temp. [°C] Emiss. Refl. temp. [°C] Remarks
Measure point 1 28.6 0.93 8.0 -
Measure point 2 25.0 0.93 8.0 -
Hot spot 1 31.7 0.93 8.0 -
Profile line:
Remarks:
Thermal Image of Photovoltaic Panel, highlighting Thermal Hot Spot on one of the panels.
Spot Temperature markers have been added to the thermal image to highlight comparative temperatures.
A Auto Hot Spot Indicator has been applied to the Thermal image to indicate the Hottest point within the
defined area.
A Temperature Profile Line Graph has been applied to highlight the temperature variation across the
Photovoltaic panels.
The thermal image is displayed in "Hot / Cold" palette.
Page 3/8
4. Demonstration Thermography report
File: Date: Measuring Time:
IV_00116.BMT 18/05/2010 14:23:30
Picture parameters:
Emissivity: 0.94
Refl. temp. [°C]: 22.0
Picture markings:
Measurement Objects Temp. [°C] Emiss. Refl. temp. [°C] Remarks
Measure point 1 27.9 0.94 22.0 -
Measure point 2 23.7 0.94 22.0 -
Hot spot 1 45.5 0.94 22.0 -
Profile line:
Remarks:
Thermal Image of Photovoltaic Panel, highlighting Thermal Hot Spot on one of the panels.
Spot Temperature markers have been added to the thermal image to highlight comparative temperatures.
A Auto Hot Spot Indicator has been applied to the Thermal image to indicate the Hottest point within the
defined area.
A Temperature Profile Line Graph has been applied to highlight the temperature variation across the
Photovoltaic panels.
The thermal image is displayed in "Iron" palette.
Page 4/8
5. Demonstration Thermography report
File: Date: Measuring Time:
IV_00327.BMT 12/09/2010 16:21:17
Picture parameters:
Emissivity: 0.94
Refl. temp. [°C]: 22.0
Picture markings:
Measurement Objects Temp. [°C] Emiss. Refl. temp. [°C] Remarks
Measure point 1 17.5 0.94 22.0 -
Measure point 2 13.3 0.94 22.0 -
Measure point 3 14.9 0.94 22.0 -
Hot spot 1 20.7 0.94 22.0 -
Profile line:
Remarks:
Thermal Image of Photovoltaic Panesl, highlighting Thermal Hot Spots on two of the panels.
Spot Temperature markers have been added to the thermal image to highlight comparative temperatures.
A Auto Hot Spot Indicator has been applied to the Thermal image to indicate the Hottest point within the
defined area.
A Temperature Profile Line Graph has been applied to highlight the temperature variation across the
Photovoltaic panels.
The Thermal image is displayed in "Iron" palette.
Page 5/8
6. Demonstration Thermography report
File: Date: Measuring Time:
IV_00128.BMT 18/06/2009 00:03:23
Picture parameters:
Emissivity: 0.93
Refl. temp. [°C]: 20.0
Picture markings:
Measurement Objects Temp. [°C] Emiss. Refl. temp. [°C] Remarks
Measure point 1 34.5 0.93 20.0 -
Measure point 2 31.7 0.93 20.0 -
Measure point 3 31.2 0.93 20.0 -
Profile line:
Remarks:
Thermal Image of Photovoltaic Panels.
Spot Temperature markers have been added to the thermal image to highlight comparative temperatures.
A Temperature Profile Line Graph has been applied to highlight the temperature variation across the
Photovoltaic panels.
The thermal image is displayed in "Iron" palette.
Page 6/8
7. Demonstration Thermography report
File: Date: Measuring Time:
IV_00325.BMT 12/09/2010 16:12:37
Picture parameters:
Emissivity: 0.94
Refl. temp. [°C]: 22.0
Picture markings:
Measurement Objects Temp. [°C] Emiss. Refl. temp. [°C] Remarks
Measure point 1 12.3 0.94 22.0 -
Measure point 2 13.0 0.94 22.0 -
Measure point 3 15.6 0.94 22.0 -
Measure point 4 18.9 0.94 22.0 -
Profile line:
Remarks:
Thermal Image of Photovoltaic Panel, highlighting Thermal Hot Spot on one of the panels.
Spot Temperature markers have been added to the thermal image to highlight comparative temperatures.
A Temperature Profile Line Graph has been applied to the thermal image to highlight the temperature
variation across the Photovoltaic panels.
The thermal image is displayed in Rainbow Palette.
Review:
Demonstration Thermography Report to highlight the capabilities of the Testo Thermal Imaging cameras and
the Testo IR software.
This is an example report for Demonstration purposes only. The report format is using the "Standard" report
template from the selection of Report Templates available in the software.
The Report is compiled from various Thermal images taken with Testo Thermal Imaging Cameras to
demonstarte the capabilities of a Thermal Imaging Camera to highlight Thermal anomalies in Photovoltaic
Panels indicating potential faults.and this report is compiled to indicate the capability of the camera and the
software for this type of Application.
Page 7/8
8. Demonstration Thermography report
Please note that any temperatures indicated on the images are "Apparent Temperatures" and may not be
truely representative. An overall emissivity value has been used in the images for these demonstartion
purposes. For accurate temperature measurement, the relevant emissivity value to the specific material to be
measured, would have to be established.
It should be noted that Testo do not provide a Thermography Consultancy Service, the images are purely for
Equipment Demonstration purposes to highlight the capabilities of the Testo range of Thermal Imaging
cameras and the Testo IR software.
It is not the purpose of the images/report to specifically identify/highlight any faults or Thermal Anomalies, or to
provide comment/observation relating to any anomalies.
Some of the features of the camera and software have also been applied to the Thermal images.
Spot Temperature markers have been added to the thermal images to indicate temperatures.
Auto Hot / Cold Spot Indicator has been applied, which automatically highlights the Hottest or Coldest point
in the defined area.
Temperature Profile Line Graph shows the temperature variation in graph form across the subject.
Palettes a variety of palettes have been used for the thermal images. Eight palettes are available on the
camera and in the software.
The images are automatically Time and Date Stamped to verify the time and date when the images were
taken.
The report also details the Emissivity value relating to the image taken.
22/04/2011 ,
Testo
Page 8/8