SlideShare ist ein Scribd-Unternehmen logo
1 von 24
Downloaden Sie, um offline zu lesen
THE
WORKPLACE GUIDE TO
ARC FLASH
SAFETY
Get answers to
your arc flash
and NFPA 70E
questions
TABLE OF
CONTENTS
Chapter 1: Understanding Arc Flash 	 3 	
	 What is Arc Flash?
	 How Can an Arc Flash Occur?
	 What Impacts the Size of an Arc Flash Event?
	 What are the Dangers of an Arc Flash Event?
Chapter 2: The NFPA 70E Standard 	 6
	 What is NFPA 70E?
	 What Does the NFPA 70E Standard Include?
Chapter 3: Risk Assessments 	 8
	 Why is a Risk Assessment Performed?
	 What is a Risk Assessment?
	 What is an Arc Flash Boundary?
	 What is the Next Step?
Chapter 4: Arc Flash Labeling 	 12
	 Who is Responsible for Labeling?
	 What Should be Labeled?
	 What if Electrical Equipment is Updated?
	 Where Should Labels be Placed?
	 What Label Format Should be Used?
	 What ANSI Header Should be Used?
	 How Durable Should Labels Be?
	 What Should Appear on an Arc Flash Label?
Chapter 5: Workplace Solutions 	 21
	 What are Some Labeling Options?
	 Who Should Perform Arc Flash Risk Assessments?
With the rising frequency of reported arc flash accidents, and the potential for
serious injury or death, arc flash is a serious concern. It's important to increase safety
and compliance in your workplace by better understanding and identifying arc
flash hazards. In this guide, get answers to your questions and learn more about
arc flash events, the NFPA 70E standard, and how to reach compliance with
labeling and risk assessments.
2
CHAPTER 1
3
UNDERSTANDING
ARC FLASH
Understanding Arc Flash
What is Arc Flash?
ARC FLASH: A short circuit through air that flashes over
from one exposed live conductor to another conductor or to
ground. This electrical fault can create a dangerous release of
energy, including thermal energy, acoustical energy, pressure
wave or debris.
How Can an Arc Flash Occur?
There are a number of ways an arc flash can occur, including:
• Coming close to a high-amp
source with a conductive
object can cause the electricity
to flash over
• Dropping a tool or creating a
spark can ignite an arc flash
• Failing equipment due to use
of substandard parts, improper
installation, or even normal wear
and tear
• Breaks or gaps in insulation
• Dust, corrosion or other impurities
on the surface of the conductor
What Impacts the Size of an Arc Flash Event?
Common variables that impact the size and energy of an arc
flash include1
:
• Amperage
• Voltage
• Arc Gap
• Closure Time
• Distance from Arc
• 3 Phase vs. Single Phase
• Confined Space
DID YOU KNOW?
An average of 30,000
arc flash incidents
occur per year.2
Chapter 1 / 4
What are the Dangers of an Arc Flash Event?
Physical Injury
Without the proper labeling, training and personal protective
equipment (PPE), an arc flash occurrence can lead to serious
burn injuries, concussions, hearing loss, shrapnel injuries,
broken bones and even death. An arc flash occurrence can
reach thousands of degrees, and skin exposure for just 1/10
of a second at 203°F can lead to third degree burns.
To help keep your workplace safe, train your employees in
safe work practices and utilize labels and awareness to keep
the message in the forefront of your workers’ minds and
reinforce the desired behavior in your facility.
Financial Impact
An arc flash occurrence can have a productivity and financial
impact as well. Total costs for arc flash accidents can range
from $12-15 million, including medical expenses, downtime,
equipment replacement, lawsuits, and insurance and
litigation fees4
. According to the Occupational Safety and
Health Administration (OSHA), some facilities have been
fined for over $500K for not being compliant with electrical
safety regulations.
Chapter 1 / 5
DID YOU KNOW?
Arc flash incidents lead to over
2,000 hospitalizations. An average
hospital stay is 19 days, at
approximately $18,000 per day.1
6
CHAPTER 2
THE NFPA 70E
STANDARD
The NFPA 70E Standard
What is NFPA 70E?
OSHA cites and fines employers for failure to protect
employees from the dangers of arc flash under regulation
29 CFR 1910.333(a). The National Fire Protection Association
(NFPA) details how to comply with this regulation through
the NFPA 70E standard, “Standard for Electrical Safety in
the Workplace.”
What Does the NFPA 70E Standard Include?
According to the NFPA 70E standard, there are six primary
responsibilities that facilities must meet, including:
	 1. Training for employees
	 2. Written safety program in place that is actionable
	 3. PPE available for employees
	 4. Insulated tools
	 5. Arc flash hazard degree calculations
	 6. Properly labeled equipment
Learn more about how risk assessments and labeling can
help you reach compliance in the following chapters.
Chapter 2 / 7
DID YOU KNOW?
An arc flash event can reach
35,000°F
1
8
CHAPTER 3
ARC FLASH RISK
ASSESSMENTS
Arc Flash Risk Assessments
Why is a Risk Assessment Performed?
An arc flash risk assessment is done for many reasons, including:
	 1. To prevent worker injury or death
	 2. To minimize equipment damage
	 3. To minimize system downtime
	 4. To comply with codes and safety regulations
	 5. To meet insurance requirements
	 6. To avoid litigation expenses
What is a Risk Assessment?
An arc flash risk assessment is a key part of what OSHA requires
as it relates to electrical hazards. The NFPA 70E 2015 edition
requires employers to conduct an arc flash risk assessment to
determine the amount of thermal energy that could be
generated from an arc flash incident. This information is then
used to define a flash protection boundary around the potential
source and determine the level of arc-rated apparel and other
PPE required to protect employees who cross the boundary from
the potential heat, light and blast of an incident.
At minimum, the safety program needs to be audited at intervals
not to exceed 3 years and arc flash risk assessments shall be
periodically reviewed at intervals not to exceed 5 years.
Chapter 3 / 9
What is an Arc Flash Boundary?
An arc flash boundary is the distance at which an electrical
arc can flash outward and endanger employees working on
electrical equipment. Additional boundary requirements include:
• Conductive Articles of Jewelry and Clothing: Watchbands,
bracelets, rings, key chains, necklaces, metal frame glasses, etc.
shall not be worn within the restricted approach boundary.
• Working Space: Shall not be used for storage. Space shall be
kept clear to permit safe operation and maintenance.
• Barricades: When the arc flash boundary is greater than the
limited approach boundary, barricades shall not be placed
closer than the arc flash boundary.
• Insulated Tools: Employees shall use insulated tools when
working inside the restricted approach boundary of exposed
energized electrical conductors.
Chapter 3 / 10
What is the Next Step?
Once an arc flash risk assessment has been conducted, in
which the arc flash boundary, the incident energy at the
working distance and the personal protective equipment
required has been determined, Article 130.5 (C) in the 2015
edition of NFPA 70E further dictates that the label must
contain these important elements.
Take a look at the below visual to learn more
about each boundary area:
Chapter 3 / 11
DID YOU KNOW?
of electrical worker
fatalities are due to
burns, not shock.280%
1. Exposed Conductor, or Circuit
2. Restricted Approach Boundary
(increased likelihood of electric shock)
3. Limited Approach Boundary
(shock hazard exists)
4. Arc Flash Boundary (distance where up
to 2nd degree burns are likely to occur -
it could be 1 inch to 20 feet and greater of
less than the other boundaries, depending
on incident energy)
WALL
1
2
3
4
12
CHAPTER 4
ARC FLASH
LABELING
Arc Flash Labeling
Who is Responsible for Labeling?
Arc flash labeling is the responsibility of the employer, not the
manufacturer or installer of the equipment.
What Should be Labeled?
Article 110.16 in NFPA 70, the National Electrical Code (NEC),
states that relevant electrical equipment shall be field marked
to warn qualified persons of potential electric arc flash hazards.
Labeling is required for any piece of electrical equipment that
is likely to require examination, adjustment, service or
maintenance while energized, creating the potential for an arc
flash incident to occur. Thus, many employers are also labeling
bus ducts and other electrical equipment not specifically called
out in the NEC.
The NEC provides the following examples of electrical equipment
that must be field marked with a warning label:
• Switchboards
• Panel Boards
• Motor Control Centers
• Industrial Control Panels
• Meter Socket Enclosures
• And More
Chapter 4 / 13
DID YOU KNOW?
Exposure of 203°F for just one-tenth
of a second (6 cycles) is enough to
cause a third degree burn.1
What if Electrical Equipment is Updated?
Any modifications or renovations to electrical equipment that will
change data on the label will require an updated arc flash risk
assessment and label according to the 2015 NFPA 70E standard.
While the labeling requirements for equipment installed prior
to the 2002 NEC Provision are not specifically stated, OSHA’s
general duty clause for hazard warning may apply here. Should
the equipment be modified or upgraded in any way, then a label
must be affixed. In fact, an OSHA representative has stated that
even changing a fuse or circuit breaker could be considered a
modification that would require labeling. Labels applied prior to
September 30, 2011 are acceptable if they contain the available
incident energy or required level of PPE.
From a safety perspective, the hazard is the same regardless of
when the equipment was installed. Consequently, most
employers are simply labeling all the appropriate equipment,
regardless of when it was installed.
Chapter 4 / 14
Where Should Labels be Placed?
The NEC requirement states that the marking must be in a
location that is clearly visible to qualified persons before they
begin work. Typically, the label is placed outside the panel or
enclosure door. In some cases, companies choose to put the label
inside the door to protect it from harsh environments. However,
this should only be done if the door must be opened (allowing the
label to be seen) in order to remove the panel face or enclosure.
The key point is that the label should be easily noticeable by
workers before they may be exposed to any potentially
dangerous live parts.
Chapter 4 / 15
How Durable Should Labels Be?
Arc flash labels must be able to withstand their usage
environment. This means that the print should not fade and the
adhesive should be aggressive enough to avoid peeling. When
necessary, an overlaminate should be applied to protect the
printed surface from harsh chemicals and exposure to sunlight.
Chapter 4 / 16
DID YOU KNOW?
The majority of patients with
electrical burns were injured
while working.3
What Label Format Should be Used?
Design and formatting of the labels should conform with the ANSI
Z535 Series of Standards For Safety Signs  Tags, according to
Article 130.7(E)(1) of NFPA 70E. This format typically includes:
• Header
• Message
• Pictogram (If used. Currently there is not a widely-accepted
symbol for indicating an arc flash hazard)
What ANSI Header Should be Used?
Neither the NFPA 70E nor the NEC requirements specify whether
to use a “Danger” or “Warning” header. However, NFPA 70E does
recommend identifying those situations in which there is a hazard
to the worker.
A commonly used guideline is to use a red “Danger” header when
the voltage is over 600 volts or when the incident energy is over
40 cals/cm2. Many employers have also standardized to using the
“Danger” signal word to indicate a situation where serious injury or
death WILL occur. If it is less than that threshold, an orange
“Warning” header is used. The employer has the final decision on
which words appear on the labels, but it is imperative that
consistency be maintained on all the labels throughout the facility.
Chapter 4 / 17
What Should Appear on an Arc Flash Label?
1. Nominal System Voltage A value assigned to a circuit or
system for the purpose of conveniently designating its voltage
class (e.g. 120/240 volts, 480/277 volts, 600 volts).
2. Arc Flash Boundary The distance at which an electrical arc
can flash outward, which may endanger employees working on
electrical equipment, where up to 2nd degree burns are likely
to occur.
Chapter 4 / 18
3. At Least One of the Following
	 a. Available incident energy and the corresponding working
distance (An incidental energy analysis is used to help
predict the incident energy of an arc flash for a specified set
of conditions. Incident energy is the amount of energy
impressed on a surface, a certain distance away from the
source, generated during an electrical arc event. This should
be measured and labeled in cal/cm2). Or the arc flash PPE
category in Table 130.7(C)(15)(A) (b) or 130.7(C)(B) for
equipment. But not both.
OR
	 b. Minimum arc rating of clothing (This also should be
expressed in cal/cm2. Arc rated clothing indicates it has been
tested for exposure to an electrical arc. This was formally
expressed as lame resistant in previous NFPA editions).
OR
	 c. Site specific level of PPE.
4.	Additional and Optional Hazard Information Some
safety-conscious employers go one step further by including
shock hazard information on the label. After all, as long as you
are going through the trouble to warn employees of arc flash
hazards, why not provide similar safety guidance for the other
electrical hazard – shock? These labels provide complete arc
flash hazard information, plus shock hazard information on the
applicable voltage, approach boundaries, and insulated glove
and tool requirements.
Chapter 4 / 19
Chapter 4 / 20
Take a look at the below label example to see what should
be included on an arc flash label:
Incident energy  corresponding
working distance
Min. arc
rating of
clothes
Arc flash
boundary
Site Specific PPE
Header
Shock hazard
information
Arc Flash and Shock Hazard
Appropriate PPE Required
FLASH PROTECTION SHOCK PROTECTION
Incident Energy at: 18 in
Shock Risk When
Cover is Removed
480 VAC
Min. Arc Rating: 0.45 cal/cm^2
Limited Approach 42 in
Arc Flash Boundary: 10 in Restricted Approach 12 in
Glove Class: 00 Bus Name:
PNL_P-5
Prot Dev: 100/3 BS-18 LAB PNL
PPE:
Shirt  pants or coverall, Nonmelting
(ASTM F1506) or Untreated Fiber) + hard hat +
safety glasses + hearing protection
21
CHAPTER 5
WORKPLACE
SOLUTIONS
Workplace Solutions
What are Some Labeling Options?
When it comes to establishing a compliant facility with arc flash
labels, there are a number of options to choose from:
• Pre-Printed Labels: Pre-printed arc flash labels with the arc
flash PPE category and a list of the required PPE, relieving the
employer from having to hand-write this information. As with
the check box labels, a version for both arc flash and shock
hazards is available.
• On-Demand Label Printing: Create and print customized
arc flash labels when and where you need them with an
on-demand label printer. This option avoids the time and trouble
associated with handwriting many labels and it allows labels to
be printed in batches as the project transitions from one area of
the plant to another. It is also a quicker solution compared to
selecting, ordering and waiting for pre-printed labels to arrive.
Chapter 4 / 22
Who Should Perform Arc Flash Risk Assessments?
Completing a best-in-class Arc Flash Risk Assessment in-house
requires time, resources and analysis software to accurately
calculate arc flash risk. In addition, simple miscalculations can
lead to incorrect incident energy levels resulting in the
improper use of PPE. Finding an Arc Flash Risk Assessment service
performed by a licensed engineer using power system analysis
software will enable you to not only reach compliance, but
maintain compliance. Addition services also include Arc Flash
Audits and Arc Flash Safety Training.
Chapter 4 / 23
DID YOU KNOW?
of burn patients
injured on the job
received flash injuries.3
34%
Learn more about arc flash labeling,
assessments and products that meet
your needs at BradyID.com/arcflash
© 2017 Brady Worldwide Inc. ALL RIGHTS RESERVED
References:
1 Workplace Safety Awareness Council. (2007). Common Electrical Hazards
in the Workplace Including Arc Flash. Retrieved 2017, from https://www.
osha.gov/dte/grant_materials/fy07/sh-16615-07/electrical_hazards2.ppt
2 Johnson, D. (2013, May 31). ISHN.com. Retrieved 2017, from Arc Flash
Statistics: http://www.ishn.com/articles/96001-arc-flash-statistics
3 Richard B. Campbell, D. A. (2015). Occupational Injuries from Electrical
Shock and Arc Flash Events. Fire Protection Research Foundation.
4 inoLECT. (2013). Arc Flash FAQ. Retrieved 2017, from inoLECT.com:
http://www.inolect.com/images/ArcFlash%20FAQ.pdf

Weitere ähnliche Inhalte

Was ist angesagt?

Electrical Safety for Non-Electrical Workers.138344394216476.OS
Electrical Safety for Non-Electrical Workers.138344394216476.OSElectrical Safety for Non-Electrical Workers.138344394216476.OS
Electrical Safety for Non-Electrical Workers.138344394216476.OS
Eiyla Hamdan
 

Was ist angesagt? (20)

Electrical Hazards on Airport
Electrical Hazards on AirportElectrical Hazards on Airport
Electrical Hazards on Airport
 
Electrical Hazards by Cooper Bussmann
Electrical Hazards by Cooper BussmannElectrical Hazards by Cooper Bussmann
Electrical Hazards by Cooper Bussmann
 
Electrical Safety Joliet Distribution Center
Electrical Safety Joliet Distribution CenterElectrical Safety Joliet Distribution Center
Electrical Safety Joliet Distribution Center
 
Guide testing-and-tagging-portable-electrical-equipment-and-residual-current-...
Guide testing-and-tagging-portable-electrical-equipment-and-residual-current-...Guide testing-and-tagging-portable-electrical-equipment-and-residual-current-...
Guide testing-and-tagging-portable-electrical-equipment-and-residual-current-...
 
English module electrical hazards
English module electrical hazardsEnglish module electrical hazards
English module electrical hazards
 
Office Electrical Safety by Berkeley Lab
Office Electrical Safety by Berkeley LabOffice Electrical Safety by Berkeley Lab
Office Electrical Safety by Berkeley Lab
 
Electrical Safety for Non-Electrical Workers.138344394216476.OS
Electrical Safety for Non-Electrical Workers.138344394216476.OSElectrical Safety for Non-Electrical Workers.138344394216476.OS
Electrical Safety for Non-Electrical Workers.138344394216476.OS
 
Electrical safety and Arc Flash Training
Electrical safety and Arc Flash TrainingElectrical safety and Arc Flash Training
Electrical safety and Arc Flash Training
 
Electrical safety
Electrical safetyElectrical safety
Electrical safety
 
Electrical Hazards and Arc Flash Awareness by RCC
Electrical Hazards and Arc Flash Awareness by RCCElectrical Hazards and Arc Flash Awareness by RCC
Electrical Hazards and Arc Flash Awareness by RCC
 
Driving Electrical Safety in Your Plant
Driving Electrical Safety in Your Plant Driving Electrical Safety in Your Plant
Driving Electrical Safety in Your Plant
 
Complete Guide to Electrical Safety in the Workplace
Complete Guide to Electrical Safety in the WorkplaceComplete Guide to Electrical Safety in the Workplace
Complete Guide to Electrical Safety in the Workplace
 
Electrical hazards and safety by Sai Chaithanya Sharma
Electrical hazards and safety by Sai Chaithanya SharmaElectrical hazards and safety by Sai Chaithanya Sharma
Electrical hazards and safety by Sai Chaithanya Sharma
 
Nfpa 70 E
Nfpa 70 ENfpa 70 E
Nfpa 70 E
 
Electrical Safety by PA L&I
Electrical Safety by PA L&IElectrical Safety by PA L&I
Electrical Safety by PA L&I
 
Electrical safety
Electrical safetyElectrical safety
Electrical safety
 
Electrical Hazards and their safety
Electrical Hazards and their safetyElectrical Hazards and their safety
Electrical Hazards and their safety
 
Electrical hazards
Electrical hazardsElectrical hazards
Electrical hazards
 
Electrical safety training based on osha 1910 standards sw
Electrical safety training based on osha 1910 standards swElectrical safety training based on osha 1910 standards sw
Electrical safety training based on osha 1910 standards sw
 
Electrical Hazarad
Electrical HazaradElectrical Hazarad
Electrical Hazarad
 

Ähnlich wie Arc flash guidebook

Arc_Flash_Labeling_Whitepaper
Arc_Flash_Labeling_WhitepaperArc_Flash_Labeling_Whitepaper
Arc_Flash_Labeling_Whitepaper
Christina Elwell
 
Introduction to Arc Flash Training by West Virginia University
Introduction to Arc Flash Training by West Virginia UniversityIntroduction to Arc Flash Training by West Virginia University
Introduction to Arc Flash Training by West Virginia University
Atlantic Training, LLC.
 
Introduction to Arc Flash - Revisions to the NFPA 70E, Electrically Safe Wor...
Introduction to Arc Flash - Revisions to the NFPA 70E, Electrically Safe Wor...Introduction to Arc Flash - Revisions to the NFPA 70E, Electrically Safe Wor...
Introduction to Arc Flash - Revisions to the NFPA 70E, Electrically Safe Wor...
Thorne & Derrick International
 
Why Test Series - Arc Flash Evaluations CS-00158
Why Test Series - Arc Flash Evaluations CS-00158Why Test Series - Arc Flash Evaluations CS-00158
Why Test Series - Arc Flash Evaluations CS-00158
Carolyn Dakis
 
Arc Flash Analysis Training by Illinois Institute of Technology
Arc Flash Analysis Training by Illinois Institute of TechnologyArc Flash Analysis Training by Illinois Institute of Technology
Arc Flash Analysis Training by Illinois Institute of Technology
Atlantic Training, LLC.
 
arcflashsolutions2-160226132648
arcflashsolutions2-160226132648arcflashsolutions2-160226132648
arcflashsolutions2-160226132648
Brian Y. Smith
 
What is an arc flash?
What is an arc flash? What is an arc flash?
What is an arc flash?
Trace Software International
 

Ähnlich wie Arc flash guidebook (20)

Arc flash q
Arc flash qArc flash q
Arc flash q
 
Arc_Flash_Labeling_Whitepaper
Arc_Flash_Labeling_WhitepaperArc_Flash_Labeling_Whitepaper
Arc_Flash_Labeling_Whitepaper
 
Introduction to Arc Flash Training by West Virginia University
Introduction to Arc Flash Training by West Virginia UniversityIntroduction to Arc Flash Training by West Virginia University
Introduction to Arc Flash Training by West Virginia University
 
Introduction to Arc Flash - Revisions to the NFPA 70E, Electrically Safe Wor...
Introduction to Arc Flash - Revisions to the NFPA 70E, Electrically Safe Wor...Introduction to Arc Flash - Revisions to the NFPA 70E, Electrically Safe Wor...
Introduction to Arc Flash - Revisions to the NFPA 70E, Electrically Safe Wor...
 
Why Test Series - Arc Flash Evaluations CS-00158
Why Test Series - Arc Flash Evaluations CS-00158Why Test Series - Arc Flash Evaluations CS-00158
Why Test Series - Arc Flash Evaluations CS-00158
 
Electrical Arc Flash Safety and Risk Management
Electrical Arc Flash Safety and Risk ManagementElectrical Arc Flash Safety and Risk Management
Electrical Arc Flash Safety and Risk Management
 
Arc Flash Analysis Training by Illinois Institute of Technology
Arc Flash Analysis Training by Illinois Institute of TechnologyArc Flash Analysis Training by Illinois Institute of Technology
Arc Flash Analysis Training by Illinois Institute of Technology
 
Arc flash analysis, electrical safety and risk assessment
Arc flash analysis, electrical safety and risk assessmentArc flash analysis, electrical safety and risk assessment
Arc flash analysis, electrical safety and risk assessment
 
Arc flash in Industry
Arc flash in Industry Arc flash in Industry
Arc flash in Industry
 
Arc flash hazard labeling do's and don'ts
Arc flash hazard labeling do's and don'tsArc flash hazard labeling do's and don'ts
Arc flash hazard labeling do's and don'ts
 
Introduction to Arc Flash/Blast Electrical Hazards
Introduction to Arc Flash/Blast Electrical HazardsIntroduction to Arc Flash/Blast Electrical Hazards
Introduction to Arc Flash/Blast Electrical Hazards
 
2015 nfpa 70 e changes
2015 nfpa 70 e changes2015 nfpa 70 e changes
2015 nfpa 70 e changes
 
Arc flash application guide
Arc flash application guideArc flash application guide
Arc flash application guide
 
Arc Flash Solutions
Arc Flash SolutionsArc Flash Solutions
Arc Flash Solutions
 
arcflashsolutions2-160226132648
arcflashsolutions2-160226132648arcflashsolutions2-160226132648
arcflashsolutions2-160226132648
 
Make India Safer with JMV LPS Ltd Electrical Equipment & Human Safety
Make India Safer with JMV LPS Ltd  Electrical Equipment & Human SafetyMake India Safer with JMV LPS Ltd  Electrical Equipment & Human Safety
Make India Safer with JMV LPS Ltd Electrical Equipment & Human Safety
 
NFPA 70E Electrical Safety in the Workplace by Hortica
NFPA 70E  Electrical Safety in the Workplace by HorticaNFPA 70E  Electrical Safety in the Workplace by Hortica
NFPA 70E Electrical Safety in the Workplace by Hortica
 
Arc flash
Arc flashArc flash
Arc flash
 
Arc flash
Arc flashArc flash
Arc flash
 
What is an arc flash?
What is an arc flash? What is an arc flash?
What is an arc flash?
 

Mehr von دكتور تامر عبدالله شراكى

Mehr von دكتور تامر عبدالله شراكى (20)

New crude oil tank farm project
New crude oil tank farm projectNew crude oil tank farm project
New crude oil tank farm project
 
المصطلحات الفنية لعلوم الحريق والاطفاء
المصطلحات الفنية لعلوم الحريق والاطفاءالمصطلحات الفنية لعلوم الحريق والاطفاء
المصطلحات الفنية لعلوم الحريق والاطفاء
 
Permit to confined_space_work
Permit to confined_space_workPermit to confined_space_work
Permit to confined_space_work
 
Risk management booklet
Risk management bookletRisk management booklet
Risk management booklet
 
How to achieve a safe workplace-e book
How to achieve a safe workplace-e bookHow to achieve a safe workplace-e book
How to achieve a safe workplace-e book
 
What to consider in planning for workplace
What to consider in planning for workplaceWhat to consider in planning for workplace
What to consider in planning for workplace
 
Workplace safety and health guidelines
Workplace safety and health guidelinesWorkplace safety and health guidelines
Workplace safety and health guidelines
 
Nebosh oil-and-gas-certificate-e book
Nebosh oil-and-gas-certificate-e bookNebosh oil-and-gas-certificate-e book
Nebosh oil-and-gas-certificate-e book
 
International technical certificate in oil and gas operational safety revisio...
International technical certificate in oil and gas operational safety revisio...International technical certificate in oil and gas operational safety revisio...
International technical certificate in oil and gas operational safety revisio...
 
Unit ia book part 2
Unit ia book part 2Unit ia book part 2
Unit ia book part 2
 
Management of international health and safety igc1 revision english
Management of international health and safety igc1 revision englishManagement of international health and safety igc1 revision english
Management of international health and safety igc1 revision english
 
Igc1 assessment arabic
Igc1 assessment arabicIgc1 assessment arabic
Igc1 assessment arabic
 
Nebosh international certificate distance learning
Nebosh international certificate distance learningNebosh international certificate distance learning
Nebosh international certificate distance learning
 
Igc1 arabic-1
Igc1  arabic-1Igc1  arabic-1
Igc1 arabic-1
 
Nebosh international diploma syllabus guide
Nebosh international diploma syllabus guideNebosh international diploma syllabus guide
Nebosh international diploma syllabus guide
 
Portable fire extinguishers
Portable fire extinguishersPortable fire extinguishers
Portable fire extinguishers
 
Arc flash guidebook
Arc flash guidebookArc flash guidebook
Arc flash guidebook
 
Niosh extramural research and training program
Niosh extramural research and training programNiosh extramural research and training program
Niosh extramural research and training program
 
Steps to using a fire extinguisher pass.infographic
Steps to using a fire extinguisher pass.infographicSteps to using a fire extinguisher pass.infographic
Steps to using a fire extinguisher pass.infographic
 
Nfpa 10 infographic
Nfpa 10 infographicNfpa 10 infographic
Nfpa 10 infographic
 

Kürzlich hochgeladen

Labelling Requirements and Label Claims for Dietary Supplements and Recommend...
Labelling Requirements and Label Claims for Dietary Supplements and Recommend...Labelling Requirements and Label Claims for Dietary Supplements and Recommend...
Labelling Requirements and Label Claims for Dietary Supplements and Recommend...
Lokesh Kothari
 
Asymmetry in the atmosphere of the ultra-hot Jupiter WASP-76 b
Asymmetry in the atmosphere of the ultra-hot Jupiter WASP-76 bAsymmetry in the atmosphere of the ultra-hot Jupiter WASP-76 b
Asymmetry in the atmosphere of the ultra-hot Jupiter WASP-76 b
Sérgio Sacani
 
SCIENCE-4-QUARTER4-WEEK-4-PPT-1 (1).pptx
SCIENCE-4-QUARTER4-WEEK-4-PPT-1 (1).pptxSCIENCE-4-QUARTER4-WEEK-4-PPT-1 (1).pptx
SCIENCE-4-QUARTER4-WEEK-4-PPT-1 (1).pptx
RizalinePalanog2
 
Seismic Method Estimate velocity from seismic data.pptx
Seismic Method Estimate velocity from seismic  data.pptxSeismic Method Estimate velocity from seismic  data.pptx
Seismic Method Estimate velocity from seismic data.pptx
AlMamun560346
 
Pests of mustard_Identification_Management_Dr.UPR.pdf
Pests of mustard_Identification_Management_Dr.UPR.pdfPests of mustard_Identification_Management_Dr.UPR.pdf
Pests of mustard_Identification_Management_Dr.UPR.pdf
PirithiRaju
 

Kürzlich hochgeladen (20)

Proteomics: types, protein profiling steps etc.
Proteomics: types, protein profiling steps etc.Proteomics: types, protein profiling steps etc.
Proteomics: types, protein profiling steps etc.
 
Labelling Requirements and Label Claims for Dietary Supplements and Recommend...
Labelling Requirements and Label Claims for Dietary Supplements and Recommend...Labelling Requirements and Label Claims for Dietary Supplements and Recommend...
Labelling Requirements and Label Claims for Dietary Supplements and Recommend...
 
Botany 4th semester file By Sumit Kumar yadav.pdf
Botany 4th semester file By Sumit Kumar yadav.pdfBotany 4th semester file By Sumit Kumar yadav.pdf
Botany 4th semester file By Sumit Kumar yadav.pdf
 
Justdial Call Girls In Indirapuram, Ghaziabad, 8800357707 Escorts Service
Justdial Call Girls In Indirapuram, Ghaziabad, 8800357707 Escorts ServiceJustdial Call Girls In Indirapuram, Ghaziabad, 8800357707 Escorts Service
Justdial Call Girls In Indirapuram, Ghaziabad, 8800357707 Escorts Service
 
Nightside clouds and disequilibrium chemistry on the hot Jupiter WASP-43b
Nightside clouds and disequilibrium chemistry on the hot Jupiter WASP-43bNightside clouds and disequilibrium chemistry on the hot Jupiter WASP-43b
Nightside clouds and disequilibrium chemistry on the hot Jupiter WASP-43b
 
Zoology 4th semester series (krishna).pdf
Zoology 4th semester series (krishna).pdfZoology 4th semester series (krishna).pdf
Zoology 4th semester series (krishna).pdf
 
Forensic Biology & Its biological significance.pdf
Forensic Biology & Its biological significance.pdfForensic Biology & Its biological significance.pdf
Forensic Biology & Its biological significance.pdf
 
TEST BANK For Radiologic Science for Technologists, 12th Edition by Stewart C...
TEST BANK For Radiologic Science for Technologists, 12th Edition by Stewart C...TEST BANK For Radiologic Science for Technologists, 12th Edition by Stewart C...
TEST BANK For Radiologic Science for Technologists, 12th Edition by Stewart C...
 
Site Acceptance Test .
Site Acceptance Test                    .Site Acceptance Test                    .
Site Acceptance Test .
 
Factory Acceptance Test( FAT).pptx .
Factory Acceptance Test( FAT).pptx       .Factory Acceptance Test( FAT).pptx       .
Factory Acceptance Test( FAT).pptx .
 
High Class Escorts in Hyderabad ₹7.5k Pick Up & Drop With Cash Payment 969456...
High Class Escorts in Hyderabad ₹7.5k Pick Up & Drop With Cash Payment 969456...High Class Escorts in Hyderabad ₹7.5k Pick Up & Drop With Cash Payment 969456...
High Class Escorts in Hyderabad ₹7.5k Pick Up & Drop With Cash Payment 969456...
 
CELL -Structural and Functional unit of life.pdf
CELL -Structural and Functional unit of life.pdfCELL -Structural and Functional unit of life.pdf
CELL -Structural and Functional unit of life.pdf
 
Asymmetry in the atmosphere of the ultra-hot Jupiter WASP-76 b
Asymmetry in the atmosphere of the ultra-hot Jupiter WASP-76 bAsymmetry in the atmosphere of the ultra-hot Jupiter WASP-76 b
Asymmetry in the atmosphere of the ultra-hot Jupiter WASP-76 b
 
Hire 💕 9907093804 Hooghly Call Girls Service Call Girls Agency
Hire 💕 9907093804 Hooghly Call Girls Service Call Girls AgencyHire 💕 9907093804 Hooghly Call Girls Service Call Girls Agency
Hire 💕 9907093804 Hooghly Call Girls Service Call Girls Agency
 
SCIENCE-4-QUARTER4-WEEK-4-PPT-1 (1).pptx
SCIENCE-4-QUARTER4-WEEK-4-PPT-1 (1).pptxSCIENCE-4-QUARTER4-WEEK-4-PPT-1 (1).pptx
SCIENCE-4-QUARTER4-WEEK-4-PPT-1 (1).pptx
 
Seismic Method Estimate velocity from seismic data.pptx
Seismic Method Estimate velocity from seismic  data.pptxSeismic Method Estimate velocity from seismic  data.pptx
Seismic Method Estimate velocity from seismic data.pptx
 
Pests of mustard_Identification_Management_Dr.UPR.pdf
Pests of mustard_Identification_Management_Dr.UPR.pdfPests of mustard_Identification_Management_Dr.UPR.pdf
Pests of mustard_Identification_Management_Dr.UPR.pdf
 
GBSN - Biochemistry (Unit 1)
GBSN - Biochemistry (Unit 1)GBSN - Biochemistry (Unit 1)
GBSN - Biochemistry (Unit 1)
 
module for grade 9 for distance learning
module for grade 9 for distance learningmodule for grade 9 for distance learning
module for grade 9 for distance learning
 
GBSN - Microbiology (Unit 2)
GBSN - Microbiology (Unit 2)GBSN - Microbiology (Unit 2)
GBSN - Microbiology (Unit 2)
 

Arc flash guidebook

  • 1. THE WORKPLACE GUIDE TO ARC FLASH SAFETY Get answers to your arc flash and NFPA 70E questions
  • 2. TABLE OF CONTENTS Chapter 1: Understanding Arc Flash 3 What is Arc Flash? How Can an Arc Flash Occur? What Impacts the Size of an Arc Flash Event? What are the Dangers of an Arc Flash Event? Chapter 2: The NFPA 70E Standard 6 What is NFPA 70E? What Does the NFPA 70E Standard Include? Chapter 3: Risk Assessments 8 Why is a Risk Assessment Performed? What is a Risk Assessment? What is an Arc Flash Boundary? What is the Next Step? Chapter 4: Arc Flash Labeling 12 Who is Responsible for Labeling? What Should be Labeled? What if Electrical Equipment is Updated? Where Should Labels be Placed? What Label Format Should be Used? What ANSI Header Should be Used? How Durable Should Labels Be? What Should Appear on an Arc Flash Label? Chapter 5: Workplace Solutions 21 What are Some Labeling Options? Who Should Perform Arc Flash Risk Assessments? With the rising frequency of reported arc flash accidents, and the potential for serious injury or death, arc flash is a serious concern. It's important to increase safety and compliance in your workplace by better understanding and identifying arc flash hazards. In this guide, get answers to your questions and learn more about arc flash events, the NFPA 70E standard, and how to reach compliance with labeling and risk assessments. 2
  • 4. Understanding Arc Flash What is Arc Flash? ARC FLASH: A short circuit through air that flashes over from one exposed live conductor to another conductor or to ground. This electrical fault can create a dangerous release of energy, including thermal energy, acoustical energy, pressure wave or debris. How Can an Arc Flash Occur? There are a number of ways an arc flash can occur, including: • Coming close to a high-amp source with a conductive object can cause the electricity to flash over • Dropping a tool or creating a spark can ignite an arc flash • Failing equipment due to use of substandard parts, improper installation, or even normal wear and tear • Breaks or gaps in insulation • Dust, corrosion or other impurities on the surface of the conductor What Impacts the Size of an Arc Flash Event? Common variables that impact the size and energy of an arc flash include1 : • Amperage • Voltage • Arc Gap • Closure Time • Distance from Arc • 3 Phase vs. Single Phase • Confined Space DID YOU KNOW? An average of 30,000 arc flash incidents occur per year.2 Chapter 1 / 4
  • 5. What are the Dangers of an Arc Flash Event? Physical Injury Without the proper labeling, training and personal protective equipment (PPE), an arc flash occurrence can lead to serious burn injuries, concussions, hearing loss, shrapnel injuries, broken bones and even death. An arc flash occurrence can reach thousands of degrees, and skin exposure for just 1/10 of a second at 203°F can lead to third degree burns. To help keep your workplace safe, train your employees in safe work practices and utilize labels and awareness to keep the message in the forefront of your workers’ minds and reinforce the desired behavior in your facility. Financial Impact An arc flash occurrence can have a productivity and financial impact as well. Total costs for arc flash accidents can range from $12-15 million, including medical expenses, downtime, equipment replacement, lawsuits, and insurance and litigation fees4 . According to the Occupational Safety and Health Administration (OSHA), some facilities have been fined for over $500K for not being compliant with electrical safety regulations. Chapter 1 / 5 DID YOU KNOW? Arc flash incidents lead to over 2,000 hospitalizations. An average hospital stay is 19 days, at approximately $18,000 per day.1
  • 6. 6 CHAPTER 2 THE NFPA 70E STANDARD
  • 7. The NFPA 70E Standard What is NFPA 70E? OSHA cites and fines employers for failure to protect employees from the dangers of arc flash under regulation 29 CFR 1910.333(a). The National Fire Protection Association (NFPA) details how to comply with this regulation through the NFPA 70E standard, “Standard for Electrical Safety in the Workplace.” What Does the NFPA 70E Standard Include? According to the NFPA 70E standard, there are six primary responsibilities that facilities must meet, including: 1. Training for employees 2. Written safety program in place that is actionable 3. PPE available for employees 4. Insulated tools 5. Arc flash hazard degree calculations 6. Properly labeled equipment Learn more about how risk assessments and labeling can help you reach compliance in the following chapters. Chapter 2 / 7 DID YOU KNOW? An arc flash event can reach 35,000°F 1
  • 8. 8 CHAPTER 3 ARC FLASH RISK ASSESSMENTS
  • 9. Arc Flash Risk Assessments Why is a Risk Assessment Performed? An arc flash risk assessment is done for many reasons, including: 1. To prevent worker injury or death 2. To minimize equipment damage 3. To minimize system downtime 4. To comply with codes and safety regulations 5. To meet insurance requirements 6. To avoid litigation expenses What is a Risk Assessment? An arc flash risk assessment is a key part of what OSHA requires as it relates to electrical hazards. The NFPA 70E 2015 edition requires employers to conduct an arc flash risk assessment to determine the amount of thermal energy that could be generated from an arc flash incident. This information is then used to define a flash protection boundary around the potential source and determine the level of arc-rated apparel and other PPE required to protect employees who cross the boundary from the potential heat, light and blast of an incident. At minimum, the safety program needs to be audited at intervals not to exceed 3 years and arc flash risk assessments shall be periodically reviewed at intervals not to exceed 5 years. Chapter 3 / 9
  • 10. What is an Arc Flash Boundary? An arc flash boundary is the distance at which an electrical arc can flash outward and endanger employees working on electrical equipment. Additional boundary requirements include: • Conductive Articles of Jewelry and Clothing: Watchbands, bracelets, rings, key chains, necklaces, metal frame glasses, etc. shall not be worn within the restricted approach boundary. • Working Space: Shall not be used for storage. Space shall be kept clear to permit safe operation and maintenance. • Barricades: When the arc flash boundary is greater than the limited approach boundary, barricades shall not be placed closer than the arc flash boundary. • Insulated Tools: Employees shall use insulated tools when working inside the restricted approach boundary of exposed energized electrical conductors. Chapter 3 / 10
  • 11. What is the Next Step? Once an arc flash risk assessment has been conducted, in which the arc flash boundary, the incident energy at the working distance and the personal protective equipment required has been determined, Article 130.5 (C) in the 2015 edition of NFPA 70E further dictates that the label must contain these important elements. Take a look at the below visual to learn more about each boundary area: Chapter 3 / 11 DID YOU KNOW? of electrical worker fatalities are due to burns, not shock.280% 1. Exposed Conductor, or Circuit 2. Restricted Approach Boundary (increased likelihood of electric shock) 3. Limited Approach Boundary (shock hazard exists) 4. Arc Flash Boundary (distance where up to 2nd degree burns are likely to occur - it could be 1 inch to 20 feet and greater of less than the other boundaries, depending on incident energy) WALL 1 2 3 4
  • 13. Arc Flash Labeling Who is Responsible for Labeling? Arc flash labeling is the responsibility of the employer, not the manufacturer or installer of the equipment. What Should be Labeled? Article 110.16 in NFPA 70, the National Electrical Code (NEC), states that relevant electrical equipment shall be field marked to warn qualified persons of potential electric arc flash hazards. Labeling is required for any piece of electrical equipment that is likely to require examination, adjustment, service or maintenance while energized, creating the potential for an arc flash incident to occur. Thus, many employers are also labeling bus ducts and other electrical equipment not specifically called out in the NEC. The NEC provides the following examples of electrical equipment that must be field marked with a warning label: • Switchboards • Panel Boards • Motor Control Centers • Industrial Control Panels • Meter Socket Enclosures • And More Chapter 4 / 13 DID YOU KNOW? Exposure of 203°F for just one-tenth of a second (6 cycles) is enough to cause a third degree burn.1
  • 14. What if Electrical Equipment is Updated? Any modifications or renovations to electrical equipment that will change data on the label will require an updated arc flash risk assessment and label according to the 2015 NFPA 70E standard. While the labeling requirements for equipment installed prior to the 2002 NEC Provision are not specifically stated, OSHA’s general duty clause for hazard warning may apply here. Should the equipment be modified or upgraded in any way, then a label must be affixed. In fact, an OSHA representative has stated that even changing a fuse or circuit breaker could be considered a modification that would require labeling. Labels applied prior to September 30, 2011 are acceptable if they contain the available incident energy or required level of PPE. From a safety perspective, the hazard is the same regardless of when the equipment was installed. Consequently, most employers are simply labeling all the appropriate equipment, regardless of when it was installed. Chapter 4 / 14
  • 15. Where Should Labels be Placed? The NEC requirement states that the marking must be in a location that is clearly visible to qualified persons before they begin work. Typically, the label is placed outside the panel or enclosure door. In some cases, companies choose to put the label inside the door to protect it from harsh environments. However, this should only be done if the door must be opened (allowing the label to be seen) in order to remove the panel face or enclosure. The key point is that the label should be easily noticeable by workers before they may be exposed to any potentially dangerous live parts. Chapter 4 / 15
  • 16. How Durable Should Labels Be? Arc flash labels must be able to withstand their usage environment. This means that the print should not fade and the adhesive should be aggressive enough to avoid peeling. When necessary, an overlaminate should be applied to protect the printed surface from harsh chemicals and exposure to sunlight. Chapter 4 / 16 DID YOU KNOW? The majority of patients with electrical burns were injured while working.3
  • 17. What Label Format Should be Used? Design and formatting of the labels should conform with the ANSI Z535 Series of Standards For Safety Signs Tags, according to Article 130.7(E)(1) of NFPA 70E. This format typically includes: • Header • Message • Pictogram (If used. Currently there is not a widely-accepted symbol for indicating an arc flash hazard) What ANSI Header Should be Used? Neither the NFPA 70E nor the NEC requirements specify whether to use a “Danger” or “Warning” header. However, NFPA 70E does recommend identifying those situations in which there is a hazard to the worker. A commonly used guideline is to use a red “Danger” header when the voltage is over 600 volts or when the incident energy is over 40 cals/cm2. Many employers have also standardized to using the “Danger” signal word to indicate a situation where serious injury or death WILL occur. If it is less than that threshold, an orange “Warning” header is used. The employer has the final decision on which words appear on the labels, but it is imperative that consistency be maintained on all the labels throughout the facility. Chapter 4 / 17
  • 18. What Should Appear on an Arc Flash Label? 1. Nominal System Voltage A value assigned to a circuit or system for the purpose of conveniently designating its voltage class (e.g. 120/240 volts, 480/277 volts, 600 volts). 2. Arc Flash Boundary The distance at which an electrical arc can flash outward, which may endanger employees working on electrical equipment, where up to 2nd degree burns are likely to occur. Chapter 4 / 18
  • 19. 3. At Least One of the Following a. Available incident energy and the corresponding working distance (An incidental energy analysis is used to help predict the incident energy of an arc flash for a specified set of conditions. Incident energy is the amount of energy impressed on a surface, a certain distance away from the source, generated during an electrical arc event. This should be measured and labeled in cal/cm2). Or the arc flash PPE category in Table 130.7(C)(15)(A) (b) or 130.7(C)(B) for equipment. But not both. OR b. Minimum arc rating of clothing (This also should be expressed in cal/cm2. Arc rated clothing indicates it has been tested for exposure to an electrical arc. This was formally expressed as lame resistant in previous NFPA editions). OR c. Site specific level of PPE. 4. Additional and Optional Hazard Information Some safety-conscious employers go one step further by including shock hazard information on the label. After all, as long as you are going through the trouble to warn employees of arc flash hazards, why not provide similar safety guidance for the other electrical hazard – shock? These labels provide complete arc flash hazard information, plus shock hazard information on the applicable voltage, approach boundaries, and insulated glove and tool requirements. Chapter 4 / 19
  • 20. Chapter 4 / 20 Take a look at the below label example to see what should be included on an arc flash label: Incident energy corresponding working distance Min. arc rating of clothes Arc flash boundary Site Specific PPE Header Shock hazard information Arc Flash and Shock Hazard Appropriate PPE Required FLASH PROTECTION SHOCK PROTECTION Incident Energy at: 18 in Shock Risk When Cover is Removed 480 VAC Min. Arc Rating: 0.45 cal/cm^2 Limited Approach 42 in Arc Flash Boundary: 10 in Restricted Approach 12 in Glove Class: 00 Bus Name: PNL_P-5 Prot Dev: 100/3 BS-18 LAB PNL PPE: Shirt pants or coverall, Nonmelting (ASTM F1506) or Untreated Fiber) + hard hat + safety glasses + hearing protection
  • 22. Workplace Solutions What are Some Labeling Options? When it comes to establishing a compliant facility with arc flash labels, there are a number of options to choose from: • Pre-Printed Labels: Pre-printed arc flash labels with the arc flash PPE category and a list of the required PPE, relieving the employer from having to hand-write this information. As with the check box labels, a version for both arc flash and shock hazards is available. • On-Demand Label Printing: Create and print customized arc flash labels when and where you need them with an on-demand label printer. This option avoids the time and trouble associated with handwriting many labels and it allows labels to be printed in batches as the project transitions from one area of the plant to another. It is also a quicker solution compared to selecting, ordering and waiting for pre-printed labels to arrive. Chapter 4 / 22
  • 23. Who Should Perform Arc Flash Risk Assessments? Completing a best-in-class Arc Flash Risk Assessment in-house requires time, resources and analysis software to accurately calculate arc flash risk. In addition, simple miscalculations can lead to incorrect incident energy levels resulting in the improper use of PPE. Finding an Arc Flash Risk Assessment service performed by a licensed engineer using power system analysis software will enable you to not only reach compliance, but maintain compliance. Addition services also include Arc Flash Audits and Arc Flash Safety Training. Chapter 4 / 23 DID YOU KNOW? of burn patients injured on the job received flash injuries.3 34%
  • 24. Learn more about arc flash labeling, assessments and products that meet your needs at BradyID.com/arcflash © 2017 Brady Worldwide Inc. ALL RIGHTS RESERVED References: 1 Workplace Safety Awareness Council. (2007). Common Electrical Hazards in the Workplace Including Arc Flash. Retrieved 2017, from https://www. osha.gov/dte/grant_materials/fy07/sh-16615-07/electrical_hazards2.ppt 2 Johnson, D. (2013, May 31). ISHN.com. Retrieved 2017, from Arc Flash Statistics: http://www.ishn.com/articles/96001-arc-flash-statistics 3 Richard B. Campbell, D. A. (2015). Occupational Injuries from Electrical Shock and Arc Flash Events. Fire Protection Research Foundation. 4 inoLECT. (2013). Arc Flash FAQ. Retrieved 2017, from inoLECT.com: http://www.inolect.com/images/ArcFlash%20FAQ.pdf