SCADA using GPRS for Substaion monitoring and Controlling without any manual operation & safety controlling of Substation from fire, smoke, like adverse effects within the substation itself
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar ≼🔝 Delhi door step de...
protype implementation of Supervisory control & data Acquisition using GPRS
1. PROTOTYPE IMPLEMENTATION OF SCADA USING GPRS FOR
SUBSTATION MONITORING AND CONTROLLING
PROJECT ASSOCIATES: 1. Irshadahmed Syed 2BA10EE402
2. Girish Gondhali 2BA09EE018
3. Shahbaz Makandar A 2BA09EE043
4.Shankrappa.Badaradinni 2BA09EE044
Guide: Co-ordinator: HOD:
Prof V.D.Holla Prof Nanda.P Dr.G.B.Mukarthihal
ELECTRICAL AND ELECTRONICS DEPARTMENT
AICTE-NBA Accredited,VTU research center
BASAVESHWARA ENGINEERING COLLEGE(Autonomous),BAGALKOT
Govt Aided,TEQIP lead institute AICTE Recognized,Affiliated to VTU Belgaum
26 November 2015 1Dept Of Electrical & Electronics Engg
3. INTRODUCTION
26 November 2015 3Dept Of Electrical & Electronics Engg
Power distribution from electrical grid.
About SCADA.
Implementation of SCADA using GPRS .
4. OBJECTIVES
To support us smart grid initiative.
To remote monitoring of critical substation components.
To increase the reliability without adding personnel.
To Ethernet and wireless connections to a central control
room.
To spot nonfunctioning equipment with low
temperatures.
To instantly trigger audible and visual alarms.
To work day or night in any weather – 24*7 operation.
26 November 2015 4Dept Of Electrical & Electronics Engg
14. 26 November 2015 Dept Of Electrical & Electronics Engg 14
OVERLOAD DETECTION CIRCUIT
FOR AC
15. ADVANTAGES
Suitable for any kind of Substations .
Suitable for private power house unit for industries.
Damage to transformers can be avoided.
Safety can be achieved .
The SCADA software is user friendly and easy way of
operation.
GPRS data transmission is very fast.
No limitation of range .
26 November 2015 15Dept Of Electrical & Electronics Engg
17. APPLICATIONS
• It is used in Water Distribution and Water
Treatment
• It is used in Industrial Sectors
• It is used in Defense Sectors
• It is used in Oil and Gas Refining Plants
• It is used in various Substations for Monitoring
and Controlling
• It can be used in Prison for Security with Alarm
system
26 November 2015 Dept Of Electrical & Electronics Engg 17
18. CONCLUSION
The prototype project of Implementation of
SCADA using GPRS for the substation monitoring
and controlling is designed such that the devices
can be monitored and also controlled from
anywhere in the world using GPRS modem
26 November 2015 18Dept Of Electrical & Electronics Engg
19. FUTURE SCOPE
• Increasing the signal strength
• SCADA systems are becoming increasingly ubiquitous.
26 November 2015 Dept Of Electrical & Electronics Engg 19
20. REFERENCES
1. Sunil Rao ”Switch gear and Protection and Power systems”, Khanna
Publishers,2004.
2. Amit sachan, “GSM based SCADA monitoring and controlling system substation
equipment”, International Journal of Engineering Research & Technology (IJERT)
Vol. 1 Issue 5, July – 2012 ISSN 2278-0181
3. Muhammad Ali Mazidi and Janice Gillespie mazidi and Rollin D.McKinlay,”The
8051 Microcontroller and Embedded systems using assembly and C
”,P.H.I/Pearson,2006.
4. M.H.Rashid, ”Power Electronics” ,2nd Edition, P.H.I./Pearson , New Delhi, 2002.
5. David A.Bell, ”Operational Amplifier and Linear IC’s ”, 2nd Edition, P.H.I,2007.
6. Dan Ehrenreich,”Wireless Data Communications for SCADA Systems,”
Vancouver,November 28-29,2005.
Websites
1. www.ckts.com
2. www.electronicsforum.com
3. http:/en.wikipedia.org/wiki/General_Packet_Radio_Service.
4. www.certec.lth.se/doc/awireless.pdf.
5. http:/en.wikipedia.org/wiki/SCADA.
26 November 2015 20Dept Of Electrical & Electronics Engg