SlideShare ist ein Scribd-Unternehmen logo
1 von 6
Downloaden Sie, um offline zu lesen
Page 1 of 6
CHP Case Studies – Saving Money and Increasing Security
Stephen F. Gillette
Capstone Turbine Corporation
ABSTRACT
Microturbines are excellent power generators for use in
combined heat and power (CHP) systems. Their low
maintenance and clean exhaust make them a reliable
choice for base load CHP applications. Integrating hot
water heat recovery into the microturbine package has
proven cost effective, and a growing number of
commercial installations are saving money using this
technology. Not only do microturbines provide this cost-
saving performance day in and day out, but their value is
further increased when the cost for traditional backup
generation is eliminated. The examples sited in this paper
are from the author’s company, Capstone Turbine, but are
intended to reflect the potential application of similar
microturbine products.
MICROTURBINE TECHNOLOGY OVERVIEW
There is no formal definition for a “microturbine,”
however the common characteristics of today’s products
are simple radial compressor and radial turbine designs
using a recuperator to preheat the combustion air for
improved efficiency. Most designs use a single shaft onto
which the radial compressor, radial turbine and generator
are all coupled. This assembly is sometimes called the
“turbo generator.” Rotating speeds are extremely high, in
the range of 45,000 to 100,000 revolutions per minute. The
generator output is therefore high frequency alternating
current. Figure 1 illustrates a microturbine turbo generator
with annular construction recuperator.
Power electronics are used to rectify this alternating
current to direct current, then invert to the three-phase 50
or 60 Hertz power frequency. Insulated gate bipolar
transistors (IGBT’s) are commonly used, and the power
electronics and controls are similar to technology used in
uninterruptible power supplies and variable frequency
motor drives. Integral computers control the conversion of
Figure 1 Turbo Generator Engine
power, operation of the turbo generator system, as well as
provide convenient man-machine interface and remote
communications. Because the designs are often so tightly
integrated with the onboard computer, operator interface
can be made both convenient and extremely powerful.
Protective relay functions are also often built into the
system, making microturbines extremely easy and safe to
connect in parallel with an electric grid. Figure 2 provides
a system diagram showing the key elements of such an
electronically controlled microturbine system. One
manufacturer uses a gearbox to transform the high-speed
turbine output to a more traditional synchronous speed
generator. In this case, synchronizing and protective
relaying control is done using traditional separate control
systems external to the microturbine.
Page 2 of 6
Microturbine turbo generators from most manufacturers
are able to operate on a variety of fuel types: natural gas,
biogas, diesel fuel, or propane. One of the characteristics of
microturbines is that the fuel must be injected into the
combustion chamber at relatively high pressure of three to
five atmospheres. When using gaseous fuels, this
requirement for fuel compression requires significant
power, which must be considered part of the microturbine
system when calculating net power output. Several
manufacturers offer a natural gas compressor either
internal to the microturbine package or directly powered
and automatically controlled by the microturbine in order
to simplify installation.
Current production microturbines range in net power
output from 28 to 250kW. The standard used by
manufacturers for rating power and electrical efficiency for
microturbines is at ISO ambient conditions of 15°C (59°F)
and sea level. Electrical efficiencies relate to the lower
heating value of the fuel (LHV), and are typically from the
mid-twenty to low-thirty percent range, depending on fuel
type and fuel compressor parasitic load. As with all
Brayton cycle engines, the power and efficiency are both
reduced with increased ambient temperature, resulting in
performance de-rating curves, which can be obtained from
the manufacturer for each specific microturbine.
Microturbines do not have reciprocating parts that require
frequent change of lubricants. Some microturbines even
utilize air bearings and air cooling, thereby completely
eliminating the need to change and dispose of hazardous
liquid lubricants and coolants. In any case, microturbines
are similar to major power plants, able to run for extended
periods at full power output, and require little scheduled
maintenance compared with traditional reciprocating
engines of similar size. This makes them ideal for
stationary prime power applications.
The combustion process in a microturbine is continuous
and clean burning, similar to modern gas turbine power
plants. Microturbine manufacturers have deployed state-of-
the-art lean-burn combustion technology to control
emissions without the need for expensive catalytic exhaust
treatment equipment or chemicals. The leading microtur-
bine manufacturers specify fewer than 9 parts per million
(ppm) NOx (0.47 pounds per megawatt-hour) and similar
emissions of CO at full power, and independent third
parties have verified that emissions measurements are
actually much lower. Because their exhaust is so clean,
microturbines are relatively easy to site virtually anywhere.
In Southern California, which has some of the strictest
emissions standards in the world, most manufacturers have
already deployed microturbines. In addition, the California
Air Resources Board (CARB) set new emissions
regulations for microturbines effective January 1, 2003,
that are output based and must be measured over several
real-world operating conditions. At least two microturbine
manufacturers have now met this strict standard, and have
had microturbine products certified to meet the CARB
standard. Future standards, set to be imposed in 2007, will
be even more stringent. This type of regulation is already
facilitating installation of microturbines in California, and
may become more widely accepted in all markets.
INTEGRATED CHP SYSTEMS
The benefits of combining the thermal and electrical
outputs of a system are widely recognized. Extracting the
exhaust energy that would otherwise be wasted increases
the total system efficiency far beyond that of fossil-fueled
utility power plants. This means more useful work from
our limited natural resources, and less greenhouse gas
emissions than using conventional energy conversion
technologies. And since microturbines are already
extremely clean burning, other exhaust emissions are
reduced as well. Figure 3 provides an example comparing
efficiency and emissions for traditional and microCHP
systems with 60 kW electric output and 120 kW heat
output. Note that total efficiency is significantly higher,
greenhouse gas emissions (CO2) are 25% less, and NOx
emissions are an order of magnitude lower for the micro-
CHP system shown. Reference emissions for the traditional
system are extracted from published US Department of
Energy data on efficiency and emissions from the average
US fossil fuel power plant, according to US EPA data.
Figure 2. – Typical Microturbine System
Fuel
System
MicroTurbine
Generator
Power
Controller
Control
Computer
Battery
(Optional)
User Interface
Exhaust
Electrical
Output
Fuel
Supply
Air
Figure 3. – Traditional vs MicroCHP System
Water Heater
80% Efficient
+
150kW
Fuel
US Average
33% Efficient
180kW
Fuel
60kW
Electricity
120kW
Hot Water
30kW
Waste
240kW
Fuel
60kW
Electricity
Microturbine
Heat
Exchanger
120kW
Hot Water
60kW
Waste
Traditional MicroCHP
• 57% Total Efficiency
• 0.2 lb/hr NOx
• 120 lb/hr CO2
• 75% Total Efficiency
• 0.02 lb/hr NOx
• 90 lb/hr CO2
Water Heater
80% Efficient
+
150kW
Fuel
US Average
33% Efficient
180kW
Fuel
60kW
Electricity
120kW
Hot Water
30kW
Waste
240kW
Fuel
60kW
Electricity
Microturbine
Heat
Exchanger
120kW
Hot Water
60kW
Waste
Water Heater
80% Efficient
+
150kW
Fuel
US Average
33% Efficient
180kW
Fuel
60kW
Electricity
US Average
33% Efficient
180kW
Fuel
60kW
Electricity
120kW
Hot Water
30kW
Waste
240kW
Fuel
60kW
Electricity
Microturbine
Heat
Exchanger
120kW
Hot Water
60kW
Waste
240kW
Fuel
60kW
Electricity
Microturbine
Heat
Exchanger
120kW
Hot Water
60kW
Waste
Traditional MicroCHP
• 57% Total Efficiency
• 0.2 lb/hr NOx
• 120 lb/hr CO2
• 75% Total Efficiency
• 0.02 lb/hr NOx
• 90 lb/hr CO2
Page 3 of 6
These benefits of combined heat and power systems are
significant for the environment and for energy
conservation. National and state governments recognize
the social values of such CHP systems, and often provide
incentives to help develop new installations. For example,
in California, the Public Utilities Commission provides up
to 30% rebates for CHP installations that meet certain size
and efficiency requirements; 40% if biogas fueled. The
economic benefit of such microturbine-based CHP systems
are becoming well accepted in the market, and example
installations will be covered later in this paper.
To continue this adoption trend, however, microCHP
systems must become even easier to apply and install. One
example is the Capstone C60 Integrated CHP System
(C60-ICHP), released in September 2003. It is, in many
ways, similar to integrated CHP systems offered by Inger-
soll-Rand and others. The Capstone C60-ICHP system was
described in detail in a related AEE paper presented at
Globalcon in Boston, Massachusetts March 24, 2004.
Figure 4 shows the C60-ICHP System.
CHP CASE STUDY #1 – RADISSON HOTEL
Two C60-ICHP systems are installed at the Radisson Hotel
in Santa Maria, California. In this application, the hot
water output is used for several different purposes. One use
is for domestic hot water for the hotel guests. This thermal
load is highest in the morning, and then increases again
later in the day. A second use is for laundry service. This is
highest during the working day. The third use is for
building heat. This load is seasonal, and steady during the
day when outside temperatures are low. Figure 5 shows the
installation of these two C60-ICHP units at the hotel.
The two C60-ICHP systems are set to operate in parallel
with the electric grid, and Electric Priority mode is used. In
this CHP mode, the electric power output for each
microturbine is set at the desired level. For this Radisson
hotel with 188 rooms, electric power is normally set for
maximum from each microturbine during the day. This is
below the building’s peak electric demand, and power does
not flow back into the electric utility grid. While the
microturbines work to maintain their programmed electri-
cal outputs, the exhaust diverters automatically adjust to
accommodate the changing thermal requirements of the
hotel. This example shows how the flexible control capa-
bilities of the C60-ICHP allow simple integration with a
building with changing thermal requirements.
The two C60-ICHP systems are set to operate 24 hours per
day. The operating scheme was selected to match the
thermal requirements of the hotel, provide the maximum
electric energy, and reduce time-of-use demand charges
from the local electric utility. This results in maximum
financial benefit to the hotel, and helps to offload the
utility when power is needed most by other customers. The
hotel’s electrical utility is PG&E, its gas utility is Sempra’s
SoCalGasCo. PowerHouse Energy supplied the ICHP
systems to the hotel and managed the installation, system
startup and continuous operation.
The ICHP application qualified for the state’s PUC Self-
Generation Incentive Program rebate of 30% on the total
installed cost. The expected energy savings are very good,
with a calculated average savings of about $5,528 a month
or $66,336 per year. This savings to the hotel is net of
natural gas, projected lifecycle maintenance costs, and
project financing. Total installed cost was $185,000 (net of
the PUC rebate), giving this project a respectable 32%
IRR. The operating availability of the ICHP systems, in-
cluding start up, commissioning, and service response time
has been better than 95% to date.
Figure 4. – C60 Integrated CHP System
Figure 5. – Two C60-ICHPs at Radisson Santa Maria
Page 4 of 6
CHP CASE STUDY #2 – INNS OF AMERICA
The Capstone microturbine installation at Inns of America
in Carlsbad, California, was completed in August 2002 by
California Power Partners (Calpwr). It included a Capstone
C60 with fuel gas booster and separate hot water heat
recovery module. Figure 6 shows the hotel with an inset
photo of the 60 kW microturbine. As for the Radisson, this
microCHP system provides both thermal and electric base
load for this hotel. Energy savings were estimated at 40%.
This lowered the daily per room energy cost by $4.00 – a
significant portion of the hotel’s profit margin.
While this installation is saving the hotel owner money
every day, there is a unique attribute that provided even
more value than anyone envisioned when the decision to
purchase this system was made. The hotel owner decided
to purchase Capstone’s dual mode version microturbine,
with the capability to provide power even when the electric
utility is not available. The logic was to avoid the cost of a
traditional backup generator, thereby improving the eco-
nomics of this project. Such traditional diesel backup
generators are designed and permitted to operate only for
short periods of time in case of a utility outage. But mic-
roturbines certified by the California Air Resources Board
can operate continuously without the need for local air
permits.
In October of 2003, Southern California was ravaged by
multiple wildfires that lasted days and crippled the state
with huge property and personal losses. Carlsbad, where
the hotel is located, and the nearby San Diego region were
especially hard hit. Power lines were shut down, and many
homes and businesses. Figure 7 is a satellite picture of
Southern California that shows the breadth of the fires’
destruction.
During this time, the Inns of America lights remained on,
powered by the Capstone 60kW microturbine. In support
of the local community, the Inns donated a number of
rooms for people who were displaced or otherwise in need.
Local businesses began using the hotel’s business center,
and the Inns of America became an emergency base of
operations for several groups. The result for the hotel was
increased business and a strengthened relationship with the
community – things that were never directly considered in
their original decision to install a microCHP system.
CHP CASE STUDY #3 – BAULI RESTAURANT
The US is not alone in facing extended power outages. On
September 28, 2003 Italy faced a multi-hour power outage.
The Bauli Grill restaurant in Verona had already installed a
Capstone C60 microturbine-based CHP system with the
help of the national electric utility. The primary driver for
this installation was cost savings, made possible with the
highly energy efficient CHP solution shown in figure 8.
Figure 7. – Satellite Photo of California Wild Fires
Figure 6. –C60 CHP System at Inns of America
Figure 8. – C60 CHP System at Bauli Restaurant
Page 5 of 6
The Bauli Grill is a full service convenience restaurant
located on the Autostrada, and operates 24 hours a day. At
about 3:30 a.m., the utility power failed. The microCHP
system was not operating at that time, as there was insuffi-
cient thermal load to make operation economical at that
early hour. However, as soon as the outage occured, the
Capstone C60 started up to provide power to critical loads
in the restaurant. This continued until about 7:30 a.m.
when utility power was restored. Figure 9 shows power
data that was recorded by the electric utility, ENEL.
Figure 9. – Bauli Grill Power Outage
0.00
10.00
20.00
30.00
40.00
50.00
60.00
70.00
80.00
90.00
3.20
6.40
Hours
kW
Start BLACK OUT
BLACK OUT stop
Cogeneration Unit in stand alone mode
Battery
recharge
Cogeneration
Unit stopped for
no request of
thermal energy
Cogeneration
Unit in grid
connect
This roadside restaurant continued to stay open and serve
travelers while virtually all of Italy was without power.
Based on this demonstrated reliability and the good CHP
economics, the owners of the Bauli Grill chain are now
considering additional installations at their other locations.
EXPECT LONGER POWER OUTAGES
Southern California and Italy are not the only areas to be
impacted by extended power outages. Whether due to
natural disaster (as was the case of the Southern California
wildfires), or the result of over-burdened utility grids (as
was the case of the August 2003 Northeast blackout),
power outages can last for many hours or even days.
In fact, there is growing concern by many in the power
industry that we face a threat of longer duration power
outages in the future. In a whitepaper entitled Critical
Power (ref www.digitalpowergroup.com), the authors des-
cribe the potential for sabotage to increase the duration of
power outages many hours to days. Figure 10 compares
this new sabotage factor to historical outage frequency and
duration curves used to design high reliability power
systems.
We can expect that security of power will become even
more important to government and private industry, and
the quickest way to achieve higher levels of security is
through onsite power generation.
TRADITIONAL BACKUP IS NOT ENOUGH
Diesel backup generators are traditionally used to protect
against extended utility power outages. However, they of-
ten fall short of expectations – especially during extended
outages.
During the August 2003 Northeast blackout, about half of
New York City’s 58 hospitals suffered backup power
failures. The reasons for this poor performance included
inability to start, breakdown after starting, and lack of suf-
ficient fuel to continue operation. The impact was exacer-
bated by the common practice of installing only one
backup generator for critical loads. The New York Daily
News described the resulting shuttling of patients from
hospital to hospital in hopes of finding one with backup
power “hospital hopscotch.”
The Wall Street Journal reported some New York hotel
operators with diesel backup generators limited the number
of loads that were protected for fear that they would run
out of fuel. And the industry’s Lodging magazine reported
that, like those at New York City hospitals, many backup
generators could not be started or failed when presented
with real-world conditions.
Solutions will include addressing problems with starting,
extending fuel supply, and adding redundancy. Natural gas
fired microCHP systems can cost-effectively address all
these elements of good design practice. Since they run for
extended periods every day (or continuously), the problems
associated with infrequent starting are not an issue. For
most outage scenarios, the natural gas supply remains
available (in fact, several Capstone microturbines at a
natural gas transmission plant in Ithaca, New York, kept
the gas flowing throughout the outage).
Figure 10. – Electric Grid Failures
Page 6 of 6
Combining microturbines into a multipac system results in
higher total system availability. And the best part is that a
microCHP system pays for itself with energy savings.
Figure 11 shows a sample calculation of how a hot water
CHP system can result in 40% savings compared to pur-
chasing power from a utility and sinking capital into a
backup generator.
Figure 11. – Energy Savings Comparison
Commercial Electricity Cost Comparison
-$0.04
-$0.02
$0.00
$0.02
$0.04
$0.06
$0.08
$0.10
$0.12
$0.14
$/kWh
CA Utility Avg
Fuel Offset
Maintenance
Installation
Equipment
Net Fuel
Source for Utility Tariffs: EIA 2002 Survey
Utility Price CHP
40% Savings
THE FUTURE IS EVEN MORE POWERFULL
The examples shown in this paper were all microCHP
systems using hot water as the thermal load. As shown in
the economics above, the savings can be dramatic where
hot water thermal loads exist; such as in hotels, restaurants,
schools, swimming pools and spas, and many industrial
processes. There is a much larger potential market for cost-
effective combined cooling, heating, and power systems
(sometimes referred to as CCHP) or trigeneration.
Figure 12. –UTC Power’s PureComfort 240M
United Technologies Corporation (UTC) recently intro-
duced a dual-effect absorption chiller – with approximately
twice the energy efficiency of single-effect chillers – that is
able to directly accept the exhaust from four 60-kW micro-
turbines. This product was developed with support from
UTC’s Carrier Corporation and the United Technologies
Research Center, and is marketed through UTC Power.
The first product is labeled “PureComfort 240M,” and is
offered as a complete trigeneration solution – including
microturbines, chiller, and pre-engineered exhaust ducting
and controls. Figure 12 shows the microturbines and ex-
haust ducting to the chiller during product development.
UTC Power has received several orders for the
PureComfort 240M, the first of which is scheduled for
installation this summer.
Several examples of microturbine-driven combined cool-
ing and power systems are now operating, using hot water
driven absorption chillers and even direct-exhaust-fired
chillers. As these combined cooling and power technol-
ogies continue to mature, the economic benefit will be-
come viable for a significant number of commercial and
industrial customers. The option to integrate backup func-
tionality for these systems adds even more value for the
increasing number of customers who are concerned about
security of power. And since summertime load demands,
and utility rates, double or triple in summer months,
creating chilled water and air using heat energy instead of
electric energy makes great sense.
CONCLUSION
Microturbines continue to find economic application in a
growing market. Integration of hot water heat recovery,
absorption chilling, and backup power functions makes for
simple solutions that save money and increase power
reliability, with the added social benefits of clean emis-
sions, reduced greenhouse gas production, and more effi-
cient use of our limited natural resources. The microCHP
case studies in this paper are just a few examples of real
commercial customers taking financial advantage of micro-
turbine technology, and commercial microCCHP case
studies are just around the corner.

Weitere ähnliche Inhalte

Was ist angesagt?

Micro turbine seminar report
Micro turbine seminar reportMicro turbine seminar report
Micro turbine seminar reportRajneesh Singh
 
Green, Sustainable Microturbines
Green, Sustainable MicroturbinesGreen, Sustainable Microturbines
Green, Sustainable MicroturbinesMurbine
 
Micro turbines for seminar
Micro turbines for seminarMicro turbines for seminar
Micro turbines for seminarISHFAQ NAJAR
 
General Biogas Presentation
General Biogas PresentationGeneral Biogas Presentation
General Biogas PresentationMurbine
 
project report MICROTURBINE BY -Asif quamar
project report MICROTURBINE BY -Asif quamarproject report MICROTURBINE BY -Asif quamar
project report MICROTURBINE BY -Asif quamarAsif Quamar
 
Combined Cycle Power Plant
Combined Cycle Power PlantCombined Cycle Power Plant
Combined Cycle Power Plantmustafa hussain
 
MICROTURBINE Abstract BY-asif quamar
MICROTURBINE Abstract  BY-asif quamarMICROTURBINE Abstract  BY-asif quamar
MICROTURBINE Abstract BY-asif quamarAsif Quamar
 
microturbine final seminar ppt
 microturbine final seminar ppt microturbine final seminar ppt
microturbine final seminar pptAsif Quamar
 
Training Report DCCPP, Dholpur
Training Report DCCPP, Dholpur Training Report DCCPP, Dholpur
Training Report DCCPP, Dholpur Yuvraj Singh
 
Ppt on DCCPP, Dholpur
Ppt on DCCPP, DholpurPpt on DCCPP, Dholpur
Ppt on DCCPP, DholpurYuvraj Singh
 
Prashant Shukla ppt on NTPC Anta
Prashant Shukla ppt on NTPC AntaPrashant Shukla ppt on NTPC Anta
Prashant Shukla ppt on NTPC Antaprashant shukla
 
NTPC DADRI THERMAL PLANT PPT
NTPC DADRI THERMAL PLANT PPTNTPC DADRI THERMAL PLANT PPT
NTPC DADRI THERMAL PLANT PPTShivam Sharma
 
Micro turbines by asif quamar
Micro turbines by asif quamarMicro turbines by asif quamar
Micro turbines by asif quamarAsif Quamar
 
Summer internship report of DCCPP
Summer internship report of DCCPPSummer internship report of DCCPP
Summer internship report of DCCPPDurgSingh
 
08b combined cycle-systems-jbc
08b combined cycle-systems-jbc08b combined cycle-systems-jbc
08b combined cycle-systems-jbcRajesh Sheoran
 

Was ist angesagt? (20)

Microturbine
MicroturbineMicroturbine
Microturbine
 
Hillman
HillmanHillman
Hillman
 
Micro turbine seminar report
Micro turbine seminar reportMicro turbine seminar report
Micro turbine seminar report
 
Green, Sustainable Microturbines
Green, Sustainable MicroturbinesGreen, Sustainable Microturbines
Green, Sustainable Microturbines
 
Micro turbines for seminar
Micro turbines for seminarMicro turbines for seminar
Micro turbines for seminar
 
General Biogas Presentation
General Biogas PresentationGeneral Biogas Presentation
General Biogas Presentation
 
Micro turbines
Micro turbinesMicro turbines
Micro turbines
 
project report MICROTURBINE BY -Asif quamar
project report MICROTURBINE BY -Asif quamarproject report MICROTURBINE BY -Asif quamar
project report MICROTURBINE BY -Asif quamar
 
Combined Cycle Power Plant
Combined Cycle Power PlantCombined Cycle Power Plant
Combined Cycle Power Plant
 
MICROTURBINE Abstract BY-asif quamar
MICROTURBINE Abstract  BY-asif quamarMICROTURBINE Abstract  BY-asif quamar
MICROTURBINE Abstract BY-asif quamar
 
microturbine final seminar ppt
 microturbine final seminar ppt microturbine final seminar ppt
microturbine final seminar ppt
 
Training Report DCCPP, Dholpur
Training Report DCCPP, Dholpur Training Report DCCPP, Dholpur
Training Report DCCPP, Dholpur
 
Ppt on DCCPP, Dholpur
Ppt on DCCPP, DholpurPpt on DCCPP, Dholpur
Ppt on DCCPP, Dholpur
 
Prashant Shukla ppt on NTPC Anta
Prashant Shukla ppt on NTPC AntaPrashant Shukla ppt on NTPC Anta
Prashant Shukla ppt on NTPC Anta
 
NTPC Farakka
NTPC FarakkaNTPC Farakka
NTPC Farakka
 
NTPC DADRI THERMAL PLANT PPT
NTPC DADRI THERMAL PLANT PPTNTPC DADRI THERMAL PLANT PPT
NTPC DADRI THERMAL PLANT PPT
 
Micro turbines by asif quamar
Micro turbines by asif quamarMicro turbines by asif quamar
Micro turbines by asif quamar
 
Summer internship report of DCCPP
Summer internship report of DCCPPSummer internship report of DCCPP
Summer internship report of DCCPP
 
Micro turbines
Micro turbinesMicro turbines
Micro turbines
 
08b combined cycle-systems-jbc
08b combined cycle-systems-jbc08b combined cycle-systems-jbc
08b combined cycle-systems-jbc
 

Ähnlich wie Wcemc04

Icetech paper the future of marine propulsion - gas hybrid power plants
Icetech paper   the future of marine propulsion - gas hybrid power plantsIcetech paper   the future of marine propulsion - gas hybrid power plants
Icetech paper the future of marine propulsion - gas hybrid power plantsEdward Eastlack, MSc
 
Cogeneration
CogenerationCogeneration
Cogenerationskdass23
 
Internship Report on Cogeneration
Internship Report on Cogeneration Internship Report on Cogeneration
Internship Report on Cogeneration Mohan Patil
 
Design of Heat Exchanger Network for VCM Distillation Unit Using Pinch Techno...
Design of Heat Exchanger Network for VCM Distillation Unit Using Pinch Techno...Design of Heat Exchanger Network for VCM Distillation Unit Using Pinch Techno...
Design of Heat Exchanger Network for VCM Distillation Unit Using Pinch Techno...IJERA Editor
 
OVERVIEW OF COGENERATION OPPORTUNITIES IN NEPALESE SUGAR SECTOR
OVERVIEW OF COGENERATION OPPORTUNITIES IN NEPALESE SUGAR SECTOR OVERVIEW OF COGENERATION OPPORTUNITIES IN NEPALESE SUGAR SECTOR
OVERVIEW OF COGENERATION OPPORTUNITIES IN NEPALESE SUGAR SECTOR eecfncci
 
IRJET- IC Engine Waste Heat Recovery Systems
IRJET- IC Engine Waste Heat Recovery SystemsIRJET- IC Engine Waste Heat Recovery Systems
IRJET- IC Engine Waste Heat Recovery SystemsIRJET Journal
 
Depc A Abusoglu
Depc A AbusogluDepc A Abusoglu
Depc A AbusogluAbusoglu
 
IRJET- Improve the Efficiency of Combined Cycle Power Plant
IRJET- Improve the Efficiency of Combined Cycle Power PlantIRJET- Improve the Efficiency of Combined Cycle Power Plant
IRJET- Improve the Efficiency of Combined Cycle Power PlantIRJET Journal
 
Options for optimizing combined cycle plants
Options for optimizing combined cycle plantsOptions for optimizing combined cycle plants
Options for optimizing combined cycle plantsHossam Zein
 
IRJET - IC Engine Waste Heat Recovery Systems
IRJET -  	  IC Engine Waste Heat Recovery SystemsIRJET -  	  IC Engine Waste Heat Recovery Systems
IRJET - IC Engine Waste Heat Recovery SystemsIRJET Journal
 
IRJET - An Experimental Evaluation of Automobile Waste Heat Recovery System u...
IRJET - An Experimental Evaluation of Automobile Waste Heat Recovery System u...IRJET - An Experimental Evaluation of Automobile Waste Heat Recovery System u...
IRJET - An Experimental Evaluation of Automobile Waste Heat Recovery System u...IRJET Journal
 
Cogeneration (chp)
Cogeneration (chp)Cogeneration (chp)
Cogeneration (chp)Saeed Saleem
 
Micro and small hydro energy systems
Micro and small hydro energy systemsMicro and small hydro energy systems
Micro and small hydro energy systemsParamjit Singh
 
To Improve Thermal Efficiency of 27mw Coal Fired Power Plant
To Improve Thermal Efficiency of 27mw Coal Fired Power PlantTo Improve Thermal Efficiency of 27mw Coal Fired Power Plant
To Improve Thermal Efficiency of 27mw Coal Fired Power PlantIJMER
 
Case Study - STP Power Saving - Bacterial Culture
Case Study - STP Power Saving - Bacterial CultureCase Study - STP Power Saving - Bacterial Culture
Case Study - STP Power Saving - Bacterial CultureFermenta Biotech Ltd
 
Review on Boiler Control Automation for Sugar Industries
Review on Boiler Control Automation for Sugar IndustriesReview on Boiler Control Automation for Sugar Industries
Review on Boiler Control Automation for Sugar IndustriesIRJET Journal
 
APPLICATIONS OF MICRO CHP IN HOSPITALS
APPLICATIONS OF MICRO CHP IN HOSPITALSAPPLICATIONS OF MICRO CHP IN HOSPITALS
APPLICATIONS OF MICRO CHP IN HOSPITALSHarshad Desai
 
CHP-BTU to Power USA United States.pdf
CHP-BTU to Power USA United States.pdfCHP-BTU to Power USA United States.pdf
CHP-BTU to Power USA United States.pdfDaniel Donatelli
 
Electric motor systems - DecarbEurope
Electric motor systems - DecarbEuropeElectric motor systems - DecarbEurope
Electric motor systems - DecarbEuropeLeonardo ENERGY
 

Ähnlich wie Wcemc04 (20)

Unit2
Unit2Unit2
Unit2
 
Icetech paper the future of marine propulsion - gas hybrid power plants
Icetech paper   the future of marine propulsion - gas hybrid power plantsIcetech paper   the future of marine propulsion - gas hybrid power plants
Icetech paper the future of marine propulsion - gas hybrid power plants
 
Cogeneration
CogenerationCogeneration
Cogeneration
 
Internship Report on Cogeneration
Internship Report on Cogeneration Internship Report on Cogeneration
Internship Report on Cogeneration
 
Design of Heat Exchanger Network for VCM Distillation Unit Using Pinch Techno...
Design of Heat Exchanger Network for VCM Distillation Unit Using Pinch Techno...Design of Heat Exchanger Network for VCM Distillation Unit Using Pinch Techno...
Design of Heat Exchanger Network for VCM Distillation Unit Using Pinch Techno...
 
OVERVIEW OF COGENERATION OPPORTUNITIES IN NEPALESE SUGAR SECTOR
OVERVIEW OF COGENERATION OPPORTUNITIES IN NEPALESE SUGAR SECTOR OVERVIEW OF COGENERATION OPPORTUNITIES IN NEPALESE SUGAR SECTOR
OVERVIEW OF COGENERATION OPPORTUNITIES IN NEPALESE SUGAR SECTOR
 
IRJET- IC Engine Waste Heat Recovery Systems
IRJET- IC Engine Waste Heat Recovery SystemsIRJET- IC Engine Waste Heat Recovery Systems
IRJET- IC Engine Waste Heat Recovery Systems
 
Depc A Abusoglu
Depc A AbusogluDepc A Abusoglu
Depc A Abusoglu
 
IRJET- Improve the Efficiency of Combined Cycle Power Plant
IRJET- Improve the Efficiency of Combined Cycle Power PlantIRJET- Improve the Efficiency of Combined Cycle Power Plant
IRJET- Improve the Efficiency of Combined Cycle Power Plant
 
Options for optimizing combined cycle plants
Options for optimizing combined cycle plantsOptions for optimizing combined cycle plants
Options for optimizing combined cycle plants
 
IRJET - IC Engine Waste Heat Recovery Systems
IRJET -  	  IC Engine Waste Heat Recovery SystemsIRJET -  	  IC Engine Waste Heat Recovery Systems
IRJET - IC Engine Waste Heat Recovery Systems
 
IRJET - An Experimental Evaluation of Automobile Waste Heat Recovery System u...
IRJET - An Experimental Evaluation of Automobile Waste Heat Recovery System u...IRJET - An Experimental Evaluation of Automobile Waste Heat Recovery System u...
IRJET - An Experimental Evaluation of Automobile Waste Heat Recovery System u...
 
Cogeneration (chp)
Cogeneration (chp)Cogeneration (chp)
Cogeneration (chp)
 
Micro and small hydro energy systems
Micro and small hydro energy systemsMicro and small hydro energy systems
Micro and small hydro energy systems
 
To Improve Thermal Efficiency of 27mw Coal Fired Power Plant
To Improve Thermal Efficiency of 27mw Coal Fired Power PlantTo Improve Thermal Efficiency of 27mw Coal Fired Power Plant
To Improve Thermal Efficiency of 27mw Coal Fired Power Plant
 
Case Study - STP Power Saving - Bacterial Culture
Case Study - STP Power Saving - Bacterial CultureCase Study - STP Power Saving - Bacterial Culture
Case Study - STP Power Saving - Bacterial Culture
 
Review on Boiler Control Automation for Sugar Industries
Review on Boiler Control Automation for Sugar IndustriesReview on Boiler Control Automation for Sugar Industries
Review on Boiler Control Automation for Sugar Industries
 
APPLICATIONS OF MICRO CHP IN HOSPITALS
APPLICATIONS OF MICRO CHP IN HOSPITALSAPPLICATIONS OF MICRO CHP IN HOSPITALS
APPLICATIONS OF MICRO CHP IN HOSPITALS
 
CHP-BTU to Power USA United States.pdf
CHP-BTU to Power USA United States.pdfCHP-BTU to Power USA United States.pdf
CHP-BTU to Power USA United States.pdf
 
Electric motor systems - DecarbEurope
Electric motor systems - DecarbEuropeElectric motor systems - DecarbEurope
Electric motor systems - DecarbEurope
 

Kürzlich hochgeladen

A Year of the Servo Reboot: Where Are We Now?
A Year of the Servo Reboot: Where Are We Now?A Year of the Servo Reboot: Where Are We Now?
A Year of the Servo Reboot: Where Are We Now?Igalia
 
Real Time Object Detection Using Open CV
Real Time Object Detection Using Open CVReal Time Object Detection Using Open CV
Real Time Object Detection Using Open CVKhem
 
GenCyber Cyber Security Day Presentation
GenCyber Cyber Security Day PresentationGenCyber Cyber Security Day Presentation
GenCyber Cyber Security Day PresentationMichael W. Hawkins
 
Factors to Consider When Choosing Accounts Payable Services Providers.pptx
Factors to Consider When Choosing Accounts Payable Services Providers.pptxFactors to Consider When Choosing Accounts Payable Services Providers.pptx
Factors to Consider When Choosing Accounts Payable Services Providers.pptxKatpro Technologies
 
Powerful Google developer tools for immediate impact! (2023-24 C)
Powerful Google developer tools for immediate impact! (2023-24 C)Powerful Google developer tools for immediate impact! (2023-24 C)
Powerful Google developer tools for immediate impact! (2023-24 C)wesley chun
 
How to convert PDF to text with Nanonets
How to convert PDF to text with NanonetsHow to convert PDF to text with Nanonets
How to convert PDF to text with Nanonetsnaman860154
 
How to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerHow to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerThousandEyes
 
Artificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and MythsArtificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and MythsJoaquim Jorge
 
The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024Rafal Los
 
CNv6 Instructor Chapter 6 Quality of Service
CNv6 Instructor Chapter 6 Quality of ServiceCNv6 Instructor Chapter 6 Quality of Service
CNv6 Instructor Chapter 6 Quality of Servicegiselly40
 
IAC 2024 - IA Fast Track to Search Focused AI Solutions
IAC 2024 - IA Fast Track to Search Focused AI SolutionsIAC 2024 - IA Fast Track to Search Focused AI Solutions
IAC 2024 - IA Fast Track to Search Focused AI SolutionsEnterprise Knowledge
 
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking MenDelhi Call girls
 
Automating Google Workspace (GWS) & more with Apps Script
Automating Google Workspace (GWS) & more with Apps ScriptAutomating Google Workspace (GWS) & more with Apps Script
Automating Google Workspace (GWS) & more with Apps Scriptwesley chun
 
The Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptxThe Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptxMalak Abu Hammad
 
2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...Martijn de Jong
 
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptxHampshireHUG
 
Advantages of Hiring UIUX Design Service Providers for Your Business
Advantages of Hiring UIUX Design Service Providers for Your BusinessAdvantages of Hiring UIUX Design Service Providers for Your Business
Advantages of Hiring UIUX Design Service Providers for Your BusinessPixlogix Infotech
 
A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)Gabriella Davis
 
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...Igalia
 
08448380779 Call Girls In Greater Kailash - I Women Seeking Men
08448380779 Call Girls In Greater Kailash - I Women Seeking Men08448380779 Call Girls In Greater Kailash - I Women Seeking Men
08448380779 Call Girls In Greater Kailash - I Women Seeking MenDelhi Call girls
 

Kürzlich hochgeladen (20)

A Year of the Servo Reboot: Where Are We Now?
A Year of the Servo Reboot: Where Are We Now?A Year of the Servo Reboot: Where Are We Now?
A Year of the Servo Reboot: Where Are We Now?
 
Real Time Object Detection Using Open CV
Real Time Object Detection Using Open CVReal Time Object Detection Using Open CV
Real Time Object Detection Using Open CV
 
GenCyber Cyber Security Day Presentation
GenCyber Cyber Security Day PresentationGenCyber Cyber Security Day Presentation
GenCyber Cyber Security Day Presentation
 
Factors to Consider When Choosing Accounts Payable Services Providers.pptx
Factors to Consider When Choosing Accounts Payable Services Providers.pptxFactors to Consider When Choosing Accounts Payable Services Providers.pptx
Factors to Consider When Choosing Accounts Payable Services Providers.pptx
 
Powerful Google developer tools for immediate impact! (2023-24 C)
Powerful Google developer tools for immediate impact! (2023-24 C)Powerful Google developer tools for immediate impact! (2023-24 C)
Powerful Google developer tools for immediate impact! (2023-24 C)
 
How to convert PDF to text with Nanonets
How to convert PDF to text with NanonetsHow to convert PDF to text with Nanonets
How to convert PDF to text with Nanonets
 
How to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerHow to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected Worker
 
Artificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and MythsArtificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and Myths
 
The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024
 
CNv6 Instructor Chapter 6 Quality of Service
CNv6 Instructor Chapter 6 Quality of ServiceCNv6 Instructor Chapter 6 Quality of Service
CNv6 Instructor Chapter 6 Quality of Service
 
IAC 2024 - IA Fast Track to Search Focused AI Solutions
IAC 2024 - IA Fast Track to Search Focused AI SolutionsIAC 2024 - IA Fast Track to Search Focused AI Solutions
IAC 2024 - IA Fast Track to Search Focused AI Solutions
 
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
 
Automating Google Workspace (GWS) & more with Apps Script
Automating Google Workspace (GWS) & more with Apps ScriptAutomating Google Workspace (GWS) & more with Apps Script
Automating Google Workspace (GWS) & more with Apps Script
 
The Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptxThe Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptx
 
2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...
 
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
 
Advantages of Hiring UIUX Design Service Providers for Your Business
Advantages of Hiring UIUX Design Service Providers for Your BusinessAdvantages of Hiring UIUX Design Service Providers for Your Business
Advantages of Hiring UIUX Design Service Providers for Your Business
 
A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)
 
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...
 
08448380779 Call Girls In Greater Kailash - I Women Seeking Men
08448380779 Call Girls In Greater Kailash - I Women Seeking Men08448380779 Call Girls In Greater Kailash - I Women Seeking Men
08448380779 Call Girls In Greater Kailash - I Women Seeking Men
 

Wcemc04

  • 1. Page 1 of 6 CHP Case Studies – Saving Money and Increasing Security Stephen F. Gillette Capstone Turbine Corporation ABSTRACT Microturbines are excellent power generators for use in combined heat and power (CHP) systems. Their low maintenance and clean exhaust make them a reliable choice for base load CHP applications. Integrating hot water heat recovery into the microturbine package has proven cost effective, and a growing number of commercial installations are saving money using this technology. Not only do microturbines provide this cost- saving performance day in and day out, but their value is further increased when the cost for traditional backup generation is eliminated. The examples sited in this paper are from the author’s company, Capstone Turbine, but are intended to reflect the potential application of similar microturbine products. MICROTURBINE TECHNOLOGY OVERVIEW There is no formal definition for a “microturbine,” however the common characteristics of today’s products are simple radial compressor and radial turbine designs using a recuperator to preheat the combustion air for improved efficiency. Most designs use a single shaft onto which the radial compressor, radial turbine and generator are all coupled. This assembly is sometimes called the “turbo generator.” Rotating speeds are extremely high, in the range of 45,000 to 100,000 revolutions per minute. The generator output is therefore high frequency alternating current. Figure 1 illustrates a microturbine turbo generator with annular construction recuperator. Power electronics are used to rectify this alternating current to direct current, then invert to the three-phase 50 or 60 Hertz power frequency. Insulated gate bipolar transistors (IGBT’s) are commonly used, and the power electronics and controls are similar to technology used in uninterruptible power supplies and variable frequency motor drives. Integral computers control the conversion of Figure 1 Turbo Generator Engine power, operation of the turbo generator system, as well as provide convenient man-machine interface and remote communications. Because the designs are often so tightly integrated with the onboard computer, operator interface can be made both convenient and extremely powerful. Protective relay functions are also often built into the system, making microturbines extremely easy and safe to connect in parallel with an electric grid. Figure 2 provides a system diagram showing the key elements of such an electronically controlled microturbine system. One manufacturer uses a gearbox to transform the high-speed turbine output to a more traditional synchronous speed generator. In this case, synchronizing and protective relaying control is done using traditional separate control systems external to the microturbine.
  • 2. Page 2 of 6 Microturbine turbo generators from most manufacturers are able to operate on a variety of fuel types: natural gas, biogas, diesel fuel, or propane. One of the characteristics of microturbines is that the fuel must be injected into the combustion chamber at relatively high pressure of three to five atmospheres. When using gaseous fuels, this requirement for fuel compression requires significant power, which must be considered part of the microturbine system when calculating net power output. Several manufacturers offer a natural gas compressor either internal to the microturbine package or directly powered and automatically controlled by the microturbine in order to simplify installation. Current production microturbines range in net power output from 28 to 250kW. The standard used by manufacturers for rating power and electrical efficiency for microturbines is at ISO ambient conditions of 15°C (59°F) and sea level. Electrical efficiencies relate to the lower heating value of the fuel (LHV), and are typically from the mid-twenty to low-thirty percent range, depending on fuel type and fuel compressor parasitic load. As with all Brayton cycle engines, the power and efficiency are both reduced with increased ambient temperature, resulting in performance de-rating curves, which can be obtained from the manufacturer for each specific microturbine. Microturbines do not have reciprocating parts that require frequent change of lubricants. Some microturbines even utilize air bearings and air cooling, thereby completely eliminating the need to change and dispose of hazardous liquid lubricants and coolants. In any case, microturbines are similar to major power plants, able to run for extended periods at full power output, and require little scheduled maintenance compared with traditional reciprocating engines of similar size. This makes them ideal for stationary prime power applications. The combustion process in a microturbine is continuous and clean burning, similar to modern gas turbine power plants. Microturbine manufacturers have deployed state-of- the-art lean-burn combustion technology to control emissions without the need for expensive catalytic exhaust treatment equipment or chemicals. The leading microtur- bine manufacturers specify fewer than 9 parts per million (ppm) NOx (0.47 pounds per megawatt-hour) and similar emissions of CO at full power, and independent third parties have verified that emissions measurements are actually much lower. Because their exhaust is so clean, microturbines are relatively easy to site virtually anywhere. In Southern California, which has some of the strictest emissions standards in the world, most manufacturers have already deployed microturbines. In addition, the California Air Resources Board (CARB) set new emissions regulations for microturbines effective January 1, 2003, that are output based and must be measured over several real-world operating conditions. At least two microturbine manufacturers have now met this strict standard, and have had microturbine products certified to meet the CARB standard. Future standards, set to be imposed in 2007, will be even more stringent. This type of regulation is already facilitating installation of microturbines in California, and may become more widely accepted in all markets. INTEGRATED CHP SYSTEMS The benefits of combining the thermal and electrical outputs of a system are widely recognized. Extracting the exhaust energy that would otherwise be wasted increases the total system efficiency far beyond that of fossil-fueled utility power plants. This means more useful work from our limited natural resources, and less greenhouse gas emissions than using conventional energy conversion technologies. And since microturbines are already extremely clean burning, other exhaust emissions are reduced as well. Figure 3 provides an example comparing efficiency and emissions for traditional and microCHP systems with 60 kW electric output and 120 kW heat output. Note that total efficiency is significantly higher, greenhouse gas emissions (CO2) are 25% less, and NOx emissions are an order of magnitude lower for the micro- CHP system shown. Reference emissions for the traditional system are extracted from published US Department of Energy data on efficiency and emissions from the average US fossil fuel power plant, according to US EPA data. Figure 2. – Typical Microturbine System Fuel System MicroTurbine Generator Power Controller Control Computer Battery (Optional) User Interface Exhaust Electrical Output Fuel Supply Air Figure 3. – Traditional vs MicroCHP System Water Heater 80% Efficient + 150kW Fuel US Average 33% Efficient 180kW Fuel 60kW Electricity 120kW Hot Water 30kW Waste 240kW Fuel 60kW Electricity Microturbine Heat Exchanger 120kW Hot Water 60kW Waste Traditional MicroCHP • 57% Total Efficiency • 0.2 lb/hr NOx • 120 lb/hr CO2 • 75% Total Efficiency • 0.02 lb/hr NOx • 90 lb/hr CO2 Water Heater 80% Efficient + 150kW Fuel US Average 33% Efficient 180kW Fuel 60kW Electricity 120kW Hot Water 30kW Waste 240kW Fuel 60kW Electricity Microturbine Heat Exchanger 120kW Hot Water 60kW Waste Water Heater 80% Efficient + 150kW Fuel US Average 33% Efficient 180kW Fuel 60kW Electricity US Average 33% Efficient 180kW Fuel 60kW Electricity 120kW Hot Water 30kW Waste 240kW Fuel 60kW Electricity Microturbine Heat Exchanger 120kW Hot Water 60kW Waste 240kW Fuel 60kW Electricity Microturbine Heat Exchanger 120kW Hot Water 60kW Waste Traditional MicroCHP • 57% Total Efficiency • 0.2 lb/hr NOx • 120 lb/hr CO2 • 75% Total Efficiency • 0.02 lb/hr NOx • 90 lb/hr CO2
  • 3. Page 3 of 6 These benefits of combined heat and power systems are significant for the environment and for energy conservation. National and state governments recognize the social values of such CHP systems, and often provide incentives to help develop new installations. For example, in California, the Public Utilities Commission provides up to 30% rebates for CHP installations that meet certain size and efficiency requirements; 40% if biogas fueled. The economic benefit of such microturbine-based CHP systems are becoming well accepted in the market, and example installations will be covered later in this paper. To continue this adoption trend, however, microCHP systems must become even easier to apply and install. One example is the Capstone C60 Integrated CHP System (C60-ICHP), released in September 2003. It is, in many ways, similar to integrated CHP systems offered by Inger- soll-Rand and others. The Capstone C60-ICHP system was described in detail in a related AEE paper presented at Globalcon in Boston, Massachusetts March 24, 2004. Figure 4 shows the C60-ICHP System. CHP CASE STUDY #1 – RADISSON HOTEL Two C60-ICHP systems are installed at the Radisson Hotel in Santa Maria, California. In this application, the hot water output is used for several different purposes. One use is for domestic hot water for the hotel guests. This thermal load is highest in the morning, and then increases again later in the day. A second use is for laundry service. This is highest during the working day. The third use is for building heat. This load is seasonal, and steady during the day when outside temperatures are low. Figure 5 shows the installation of these two C60-ICHP units at the hotel. The two C60-ICHP systems are set to operate in parallel with the electric grid, and Electric Priority mode is used. In this CHP mode, the electric power output for each microturbine is set at the desired level. For this Radisson hotel with 188 rooms, electric power is normally set for maximum from each microturbine during the day. This is below the building’s peak electric demand, and power does not flow back into the electric utility grid. While the microturbines work to maintain their programmed electri- cal outputs, the exhaust diverters automatically adjust to accommodate the changing thermal requirements of the hotel. This example shows how the flexible control capa- bilities of the C60-ICHP allow simple integration with a building with changing thermal requirements. The two C60-ICHP systems are set to operate 24 hours per day. The operating scheme was selected to match the thermal requirements of the hotel, provide the maximum electric energy, and reduce time-of-use demand charges from the local electric utility. This results in maximum financial benefit to the hotel, and helps to offload the utility when power is needed most by other customers. The hotel’s electrical utility is PG&E, its gas utility is Sempra’s SoCalGasCo. PowerHouse Energy supplied the ICHP systems to the hotel and managed the installation, system startup and continuous operation. The ICHP application qualified for the state’s PUC Self- Generation Incentive Program rebate of 30% on the total installed cost. The expected energy savings are very good, with a calculated average savings of about $5,528 a month or $66,336 per year. This savings to the hotel is net of natural gas, projected lifecycle maintenance costs, and project financing. Total installed cost was $185,000 (net of the PUC rebate), giving this project a respectable 32% IRR. The operating availability of the ICHP systems, in- cluding start up, commissioning, and service response time has been better than 95% to date. Figure 4. – C60 Integrated CHP System Figure 5. – Two C60-ICHPs at Radisson Santa Maria
  • 4. Page 4 of 6 CHP CASE STUDY #2 – INNS OF AMERICA The Capstone microturbine installation at Inns of America in Carlsbad, California, was completed in August 2002 by California Power Partners (Calpwr). It included a Capstone C60 with fuel gas booster and separate hot water heat recovery module. Figure 6 shows the hotel with an inset photo of the 60 kW microturbine. As for the Radisson, this microCHP system provides both thermal and electric base load for this hotel. Energy savings were estimated at 40%. This lowered the daily per room energy cost by $4.00 – a significant portion of the hotel’s profit margin. While this installation is saving the hotel owner money every day, there is a unique attribute that provided even more value than anyone envisioned when the decision to purchase this system was made. The hotel owner decided to purchase Capstone’s dual mode version microturbine, with the capability to provide power even when the electric utility is not available. The logic was to avoid the cost of a traditional backup generator, thereby improving the eco- nomics of this project. Such traditional diesel backup generators are designed and permitted to operate only for short periods of time in case of a utility outage. But mic- roturbines certified by the California Air Resources Board can operate continuously without the need for local air permits. In October of 2003, Southern California was ravaged by multiple wildfires that lasted days and crippled the state with huge property and personal losses. Carlsbad, where the hotel is located, and the nearby San Diego region were especially hard hit. Power lines were shut down, and many homes and businesses. Figure 7 is a satellite picture of Southern California that shows the breadth of the fires’ destruction. During this time, the Inns of America lights remained on, powered by the Capstone 60kW microturbine. In support of the local community, the Inns donated a number of rooms for people who were displaced or otherwise in need. Local businesses began using the hotel’s business center, and the Inns of America became an emergency base of operations for several groups. The result for the hotel was increased business and a strengthened relationship with the community – things that were never directly considered in their original decision to install a microCHP system. CHP CASE STUDY #3 – BAULI RESTAURANT The US is not alone in facing extended power outages. On September 28, 2003 Italy faced a multi-hour power outage. The Bauli Grill restaurant in Verona had already installed a Capstone C60 microturbine-based CHP system with the help of the national electric utility. The primary driver for this installation was cost savings, made possible with the highly energy efficient CHP solution shown in figure 8. Figure 7. – Satellite Photo of California Wild Fires Figure 6. –C60 CHP System at Inns of America Figure 8. – C60 CHP System at Bauli Restaurant
  • 5. Page 5 of 6 The Bauli Grill is a full service convenience restaurant located on the Autostrada, and operates 24 hours a day. At about 3:30 a.m., the utility power failed. The microCHP system was not operating at that time, as there was insuffi- cient thermal load to make operation economical at that early hour. However, as soon as the outage occured, the Capstone C60 started up to provide power to critical loads in the restaurant. This continued until about 7:30 a.m. when utility power was restored. Figure 9 shows power data that was recorded by the electric utility, ENEL. Figure 9. – Bauli Grill Power Outage 0.00 10.00 20.00 30.00 40.00 50.00 60.00 70.00 80.00 90.00 3.20 6.40 Hours kW Start BLACK OUT BLACK OUT stop Cogeneration Unit in stand alone mode Battery recharge Cogeneration Unit stopped for no request of thermal energy Cogeneration Unit in grid connect This roadside restaurant continued to stay open and serve travelers while virtually all of Italy was without power. Based on this demonstrated reliability and the good CHP economics, the owners of the Bauli Grill chain are now considering additional installations at their other locations. EXPECT LONGER POWER OUTAGES Southern California and Italy are not the only areas to be impacted by extended power outages. Whether due to natural disaster (as was the case of the Southern California wildfires), or the result of over-burdened utility grids (as was the case of the August 2003 Northeast blackout), power outages can last for many hours or even days. In fact, there is growing concern by many in the power industry that we face a threat of longer duration power outages in the future. In a whitepaper entitled Critical Power (ref www.digitalpowergroup.com), the authors des- cribe the potential for sabotage to increase the duration of power outages many hours to days. Figure 10 compares this new sabotage factor to historical outage frequency and duration curves used to design high reliability power systems. We can expect that security of power will become even more important to government and private industry, and the quickest way to achieve higher levels of security is through onsite power generation. TRADITIONAL BACKUP IS NOT ENOUGH Diesel backup generators are traditionally used to protect against extended utility power outages. However, they of- ten fall short of expectations – especially during extended outages. During the August 2003 Northeast blackout, about half of New York City’s 58 hospitals suffered backup power failures. The reasons for this poor performance included inability to start, breakdown after starting, and lack of suf- ficient fuel to continue operation. The impact was exacer- bated by the common practice of installing only one backup generator for critical loads. The New York Daily News described the resulting shuttling of patients from hospital to hospital in hopes of finding one with backup power “hospital hopscotch.” The Wall Street Journal reported some New York hotel operators with diesel backup generators limited the number of loads that were protected for fear that they would run out of fuel. And the industry’s Lodging magazine reported that, like those at New York City hospitals, many backup generators could not be started or failed when presented with real-world conditions. Solutions will include addressing problems with starting, extending fuel supply, and adding redundancy. Natural gas fired microCHP systems can cost-effectively address all these elements of good design practice. Since they run for extended periods every day (or continuously), the problems associated with infrequent starting are not an issue. For most outage scenarios, the natural gas supply remains available (in fact, several Capstone microturbines at a natural gas transmission plant in Ithaca, New York, kept the gas flowing throughout the outage). Figure 10. – Electric Grid Failures
  • 6. Page 6 of 6 Combining microturbines into a multipac system results in higher total system availability. And the best part is that a microCHP system pays for itself with energy savings. Figure 11 shows a sample calculation of how a hot water CHP system can result in 40% savings compared to pur- chasing power from a utility and sinking capital into a backup generator. Figure 11. – Energy Savings Comparison Commercial Electricity Cost Comparison -$0.04 -$0.02 $0.00 $0.02 $0.04 $0.06 $0.08 $0.10 $0.12 $0.14 $/kWh CA Utility Avg Fuel Offset Maintenance Installation Equipment Net Fuel Source for Utility Tariffs: EIA 2002 Survey Utility Price CHP 40% Savings THE FUTURE IS EVEN MORE POWERFULL The examples shown in this paper were all microCHP systems using hot water as the thermal load. As shown in the economics above, the savings can be dramatic where hot water thermal loads exist; such as in hotels, restaurants, schools, swimming pools and spas, and many industrial processes. There is a much larger potential market for cost- effective combined cooling, heating, and power systems (sometimes referred to as CCHP) or trigeneration. Figure 12. –UTC Power’s PureComfort 240M United Technologies Corporation (UTC) recently intro- duced a dual-effect absorption chiller – with approximately twice the energy efficiency of single-effect chillers – that is able to directly accept the exhaust from four 60-kW micro- turbines. This product was developed with support from UTC’s Carrier Corporation and the United Technologies Research Center, and is marketed through UTC Power. The first product is labeled “PureComfort 240M,” and is offered as a complete trigeneration solution – including microturbines, chiller, and pre-engineered exhaust ducting and controls. Figure 12 shows the microturbines and ex- haust ducting to the chiller during product development. UTC Power has received several orders for the PureComfort 240M, the first of which is scheduled for installation this summer. Several examples of microturbine-driven combined cool- ing and power systems are now operating, using hot water driven absorption chillers and even direct-exhaust-fired chillers. As these combined cooling and power technol- ogies continue to mature, the economic benefit will be- come viable for a significant number of commercial and industrial customers. The option to integrate backup func- tionality for these systems adds even more value for the increasing number of customers who are concerned about security of power. And since summertime load demands, and utility rates, double or triple in summer months, creating chilled water and air using heat energy instead of electric energy makes great sense. CONCLUSION Microturbines continue to find economic application in a growing market. Integration of hot water heat recovery, absorption chilling, and backup power functions makes for simple solutions that save money and increase power reliability, with the added social benefits of clean emis- sions, reduced greenhouse gas production, and more effi- cient use of our limited natural resources. The microCHP case studies in this paper are just a few examples of real commercial customers taking financial advantage of micro- turbine technology, and commercial microCCHP case studies are just around the corner.