Nalco Tracer Technology Is Now Available
in a pHe Buffering Ethanol Corrosion Inhibitor
GIVING ETHANOL PRODUCERS UNPRECENDENTED POWER TO MANAGE ETHANOL QUALITY
Ethanol corrosion inhibitor is vital tool for fuel marketers. Proper dosage prevents corrosion and protects fuel system components. Ethanol corrosion inhibitor dosage has long been difficult to control because there wasn’t a good way to measure inhibitor content.
To solve the problem, Nalco adapted our Trasar Technology – which Nalco has used in water treatment chemicals for 20+ years to this important fuel additive. Now ethanol producers and their customers can be assured that the optimal amount of EC5624ATR has been added.
1. EC5624ATR
Ethanol Corrosion Inhibitor
Essential Expertise Don't waste it. . . trace it!
for Water, Energy and Air
And maintain consistent concentration.
SM
2. Nalco 3D TRASAR® Technology is now
EC5624ATR gives ethanol producers unprecedented
power to manage fuel ethanol quality..and control costs.
An ethanol corrosion inhibitor is a vital tool for fuel marketers. Proper dosage
prevents corrosion and protects fuel system components. Ethanol corrosion inhibitor
Measure it Easily. dosage has long been difficult to control because there has not been an effective way
to measure inhibitor content.
To solve the problem, Nalco adapted its 3D TRASAR technology, which has been
Measure it Fast. used in water treatment chemicals for 20+ years, to this important fuel additive. Now,
ethanol producers and their customers can be assured that the optimal amount of
EC5624ATR has been added. Every batch. Every day.
Measure it Accurately.
Nalco makes it easy to get it “just right,”
helping ethanol producers make better fuel.
EC5624ATR provides corrosion inhibition and pHe buffering to neutralize acids
and alkalinity that can be present in fuel ethanol. However, the amount of corrosion
inhibition and pHe buffering required can vary from plant to plant and day to day:
• Some plant designs may produce • E10, E12 and E15 blends may require
ethanol that requires more or less more or less inhibitor than E85.
inhibitor. • Most producers strive to follow the treat
• Variance in day-to-day plant operations rate approved by the RFA for various
can affect the need for more or less corrosion inhibitors. Nalco’s recom-
inhibitor. mended treat rate will be listed there.
Simple measurement.
Measurement of EC5624ATR concentration is quickly and easily accomplished
using the Nalco handheld fluorometer. The proprietary flourescing molecules
contained in the corrosion inhibitor are instantly and accurately determined.
• Treat rate measurements are made • The required sample size is only 4 mls.
in seconds. • Accurate to +/- 1 PPM.
• No sample pre-treatment or • Treat rate data can easily be added to
reagents are required. the certificate of analysis.
• Calibration takes less than 1 minute.
Using the EC5624ATR chemistry and measurement systems, all ethanol producers
now have the power to easily manage cost and quality. No wasteful overdosing. No
returned loads due to under dosing.
3. available in a pHe Buffering Corrosion Inhibitor
NALCO 360 Service monitors EC5624ATR consumption.
In addition to precision control of concentration, Nalco
offers automatic monitoring of treat rate and inventory. The
Nalco Global Gateway and tank level monitoring system
provides a second layer of treat rate monitoring and
inventory management.
• Expert remote monitoring that works 24/7,
365 days a year.
• On-line inventory monitoring with low tank level and
high consumption alarms via e-mail and SMS text.
• Prevents costly over-treatment.
• Helps you manage chemical inventory.
Nalco Account Management.
Like all Nalco products, EC5624ATR comes with a
qualified Nalco Sales Engineer. Our professional field
personnel act as an extension of your own engineering
staff and visit your facility on a regular basis.
Fuel Ethanol benefits from long term pHe buffering… 10.00
pHe Stability Study in High pHe Ethanol
and EC5624ATR delivers it. 9.00
Blank (Untreated) EC5624A@ 15 PTBE
• Fuel ethanol can be quite corrosive to fuel pumps and 8.00
injectors if the pHe is too low. 7.00
• Fuel ethanol can damage important seals and o-rings 6.00
if pHe is too high.
pHe
5.00
• Without proper pHe buffering, the pHe will drift over time. 4.00
• Fuel ethanol can often spend weeks in transport viarail, 3.00
barge, or ship, and spend weeks more in terminal fueling 2.00
stations and idle cars, so long-term pHe buffering is vital. 1.00
• Only EC5624ATR makes it fast and easy for ethanol 0.00
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
producers to add exactly the right amount every time. at End of Week
• Fuel marketers that choose ethanol treated with
EC5624ATR know they can make ethanol blends that pHe Stability Study in Very Low pHe Ethanol
won’t contribute to corrosion or elastomer damage.
8.00
Blank (Untreated) EC5624A@ 15 PTBE
7.00
6.00
EC5624ATR is a Superior Formula. 5.00
• Low sulfer content.
pHe
4.00
• A clear bright solution – like your ethanol.
• Extremely low Trimer acid content.
3.00
• Excellent cold weather pumpability. 2.00
• Excellent solubility in ethanol and denaturant. 1.00
0.00
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
at End of Week