1. Welcome to PHOENIX CONTACT
CLIPLINE complete
Electromagnetic and
electronic circuit-breaker
2. Circuit Breaker UT 6-TMC M
Thermomagnetic Circuit
Breaker as part of
CLIPLINE complete
UT 6-TMC M 0,5A
UT 6-TMC M 1A
…
UT 6-TMC M 2A
…
UT 6-TMC M 4A
…
UT 6-TMC M 5A
…
UT 6-TMC M 6A
…
UT 6-TMC M 8A
…
UT 6-TMC M 10A
…
UT 6-TMC M 12A
…
UT 6-TMC M 15A
…
UT 6-TMC M 16A
2 / Name / Department / Date
Highlights
3. Circuit Breaker UT 6-TMC M
Time-saving
Due to the plug bridge no need
for wiring
Two bridge channels for the
standard FBS x-6 bridge
3 / Name / Department / Date
4. Circuit Breaker UT 6-TMC M
Fast and clear marking
-F18
Clear marking for device and
connection point information
37
Three positions for UC-TM12 or
ZB 12 marking material. Enough
space for big and easy readable
designations.
4 / Name / Department / Date
38
5. Circuit Breaker UT 6-TMC M
High quality impression
Exact positioning of all markers
5 / Name / Department / Date
6. Circuit Breaker UT 6-TMC M
Space-saving
30% less space required
6 / Name / Department / Date
12,3
17,5
7. Circuit Breaker UT 6-TMC M
High availability
Clear visibility of the switching
status. This allows a fast
identification of the faulty circuit.
If the circuit breaker is switched
„off“ you can see the white collar.
7 / Name / Department / Date
8. Circuit Breaker UT 6-TMC M
Phoenix Contact product
No competitive product in the
market
8 / Name / Department / Date
9. Circuit Breaker UT 6-TMC M
Approvals
Certification
Body
Standard
Approved as
VDE
IEC 60934
Circuit Breaker
for Equipment
UL
UL 1077
Supplementary
Protector
UL
CSA 22.2 No. 235
Supplementary
Protector
9 / Name / Department / Date
File-No.
Approval Mark
11. Circuit Breaker – Product Range
ECP
TMC
11 / Name / Department / Date
ECP-E
TMCP
EC-E
TCP
TCP/DC
12. Circuit Breaker
Thermal protection
Thermomagnetic protection
Electronic protection
12 / Name / Department / Date
13. Circuit Breaker - Shut-down behavior
Overload
Thermal
Thermal
&
magnetic
Electronic
13 / Name / Department / Date
Short Circuit
Application
Overload
14. Thermal Switch-off
TCP
TCP...
Switching capacity
max. 8 x IN
Nominal current
0.1 A – 10 A
Voltage
AC 250 V / DC 65 V
Marking
Yes
Switching function
On & off switch incl.
electric isolation
14 / Name / Department / Date
16. Thermal Switch-off
TCP - comparison
TCP...
TCP.../DC32V
Switching capacity
max. 8 x IN
150 A
Nominal current
0.1 A – 10 A
5 A – 30 A
Voltage
AC 250 V / DC 65 V
DC 32 V
Marking
Yes
No
Switching function
On & off switch incl.
electric isolation
Can be switched back on
again incl. electric isolation
16 / Name / Department / Date
17. Thermal Switch-off
TCP/DC - Areas of applications
Cars & Trucks
Shipbuilding
Industry
Protection of DC board and battery systems
17 / Name / Department / Date
18. Thermal Switch-off
TCP – Socket und accessoires
UK 6-FSI/C
18 / Name / Department / Date
UK 4-FSI/C
19. Circuit Breaker
Thermal protection
Thermomagnetic protection
Electronic protection
19 / Name / Department / Date
20. Circuit Breaker - Shut-down behavior
Overload
Short Circuit
Application
Thermal
Overload
Thermal
&
magnetic
Overload,
Short circuit
Electronic
20 / Name / Department / Date
21. Magnetic Switch-off
TMC - Comparison
TMC...
UT 6-TMC...
Switching capacity
max. 800 A
max. 800 A
Nominal current
0.2A...16A
0,5A...16A
Nominal voltage
AC 250V / DC 65V
AC 240V / DC 28V
Shut-down behavior
Fast blow and normal
normal
Approbation
UL 1077
UL 1077
Width
12.5 mm
12,3 mm
21 / Name / Department / Date
22. Magnetic Switch-off
TMCP Socket and Accessoires
Fixed bridge pluggable
FBST 500 TMCP
Socket – 2-position
TMCP Socket M
Termination element
TMCP Connect LR
22 / Name / Department / Date
Signal bridge for free
slots TMCP SB
23. Device protection with system
Thermomagnetic Circuit Breaker
at the CLIPLINE complete Push-In-System
23 / Name / Department / Date
24. Magnetic Switch-off
TMC & TMCP-Applications
Industry
Plant construction
Machine building
Secondary protection for industrial systems
24 / Name / Department / Date
25. Circuit Breaker
Thermal protection
Thermomagnetic protection
Electronic protection
25 / Name / Department / Date
26. Circuit Breaker - Shut-down behavior
Overload
Short Circuit
Application
Thermal
Overload
Thermal
&
magnetic
Overload,
Short circuit
Electronic
Overload,
Short circuit
1.8 x IN
26 / Name / Department / Date
1.8 x IN
Attenuation/Capacity
27. Electronic Switch-off
ECP - comparison
ECP
Voltage
DC 24V
Nominal current
1A...10A
Current limiting
1.8 x IN
Elec. Isolation
Yes
Assembly
Pluggable on
TMCP-Socket-M
27 / Name / Department / Date
28. Electronic Switch-off
ECP - Comparison
ECP
ECP-E...
Voltage
DC 24V
DC 24V
Nominal current
1A...10A
1A...12A
Current limiting
1.8 x IN
1.8 x IN
Elec. Isolation
Yes
No
Assembly
Pluggable on
Pluggable on
TMCP-Socket-M
TMCP-Socket-M
28 / Name / Department / Date
29. Electronic Switch-off
ECP - Comparison
ECP
ECP-E...
EC-E...
Voltage
DC 24V
DC 24V
DC 24V
Nominal current
1A...10A
1A...12A
1A...12A
Current limiting
1.8 x IN
1.8 x IN
1.8 x IN
Elec. Isolation
Yes
No
Assembly
Pluggable on
No
Pluggable on
TMCP-Socket-M
TMCP-Socket-M
29 / Name / Department / Date
Din-Rail
mountable
31. Electronic Switch-off
EC(P) Applications
24 VDC-circuits
Plant construction
Machine building
Controllable secondary protection with status signal
31 / Name / Department / Date
34. Specific Characteristic
What is the load behavior?
Transmission – how long is the wire?
How much space is available?
How to define the circuit breaker?
34 / Name / Department / Date
36. Cable Length
MCB
EC-E
Nominal
C, 6 A
6A
Short Cicuit Area
>7-times
1,8-times
Trip Current
>42 A
~11 A
Max. Resistance
24V/42A= 0,57 Ohm
24V/11A= 2,18 Ohm
Length at 1,0mm²
15 meter
50 meter
Length at 0,5mm²
5 meter
30 meter
Length at 0,34mm²
effects source
20 meter
Transmission – How long is the wire?
36 / Name / Department / Date
37. Assembly
175mm : 5pol = 35mm
62,5mm : 5pol = 12,5mm
How much space is available?
37 / Name / Department / Date
42. All at a glace
Small and compact design
Energy-saving by current limitation
Secure on long wires
Easy assembly by pluggable
bridges
Highest value at capacities
Distribution up to 50 A
42 / Name / Department / Date
Hinweis der Redaktion
Als erstes beschäftigt uns natürlich das CLIPLINE complete System in dem wir wieder viele Neuheiten realisiert haben.
Das nächste bedeutende Thema ist die Markierung. Hier eröffnen sich uns riesige Potenziale und ich möchte Ihnen aufzeigen, wie wir diesem Thema begegnen.
Als drittes Thema haben wir die Schutzschalter. Schon seit mehr als 10 Jahren erzielen wir mit den von ETA gebrandlabelten Produkten ständig Umsatzsteigerungen.
Auch hier giebt es eine Menge an neuen Produkten, die wir Ihnen im Detail vorstellen möchten.
Als erstes beschäftigt uns natürlich das CLIPLINE complete System in dem wir wieder viele Neuheiten realisiert haben.
Das nächste bedeutende Thema ist die Markierung. Hier eröffnen sich uns riesige Potenziale und ich möchte Ihnen aufzeigen, wie wir diesem Thema begegnen.
Als drittes Thema haben wir die Schutzschalter. Schon seit mehr als 10 Jahren erzielen wir mit den von ETA gebrandlabelten Produkten ständig Umsatzsteigerungen.
Auch hier giebt es eine Menge an neuen Produkten, die wir Ihnen im Detail vorstellen möchten.
Als erstes beschäftigt uns natürlich das CLIPLINE complete System in dem wir wieder viele Neuheiten realisiert haben.
Das nächste bedeutende Thema ist die Markierung. Hier eröffnen sich uns riesige Potenziale und ich möchte Ihnen aufzeigen, wie wir diesem Thema begegnen.
Als drittes Thema haben wir die Schutzschalter. Schon seit mehr als 10 Jahren erzielen wir mit den von ETA gebrandlabelten Produkten ständig Umsatzsteigerungen.
Auch hier giebt es eine Menge an neuen Produkten, die wir Ihnen im Detail vorstellen möchten.