SlideShare ist ein Scribd-Unternehmen logo
1 von 11
Downloaden Sie, um offline zu lesen
1
The role of open source technology based equipment in developing reliable, customizable and cost-
effective aquifer model for site remediation
by Campioni A., Losi P., Angelozzi I., and Santoro L. B.
Abstract
Improving the understanding of the conceptual model of a contaminated site, is key to increase the
efficiency of the remediation techniques to apply. In particular, with regard to the contaminated
groundwater, a reliable reconstruction of the aquifer’s structure is important to develop a numerical model
of the site and identify contaminants transport pathways and fate, since the mass flux is predominant
through the most permeable layers. Aquifers characterization traditionally make use of aquifer pumping
tests and is often expensive and unsustainable since it involves management and disposal of large amounts
of potentially contaminated water. It also requires the employment of one or more field operators to
correctly carry out the tests. Therefore, the tendency is to develop tests that do not involve pumping of
large volumes of water and provide in-depth details of aquifer’s characteristics.
An experimental methodology for the direct measurement of the groundwater filtration velocity and
implying a low-cost, down-well electrical conductivity logging device was developed for data acquisition
during a single point dilution test (SPD test). The electrical conductivity logging device used to perform the
test was designed and assembled in-house in order to meet the specific needs related to the field test
protocol and investigation scopes: it is lightweight, can be remotely controlled and operable by one person.
The present paper summarizes the results of a SPD test performed on a monitoring well installed in a
contaminated site in Central Italy, and demonstrates the advantages of a versatile device specifically
designed and built for the test needs. The device has proved to produce extremely reliable and accurate
data that can be used to improve the conceptual site model for designing site remediation activities.
Moreover the device can be built with minimal cost by using open source hardware and software, therefore
implying more flexibility also in case of changes required to adapt the device to the particular set-up of one
or more field tests.
The article also includes an evaluation of the specific technology for future enhancement of the system that
can make it even more versatile and cost-effective.
Introduction
A numerical model is necessary to design effective and efficient remediation activities. It is used for
understanding the hydrogeological system and its behaviour, and for predicting its response to any stress
applied to it. The effectiveness of a groundwater numerical model in representing the real world is strongly
dependent on the goodness of the data used to build it. Hence being able to collect reliable data in a cost-
effective way is nowadays a key aspect for any remediation design.
Performing aquifer pumping tests in a contaminated environment has always posed several difficulties and
risks, e.g. production of wastes, health and safety risks due to handling contaminated water, etc., while
quick aquifer tests (e.g. slug tests), not involving pumping of contaminated groundwater, do not always
provide reliable results. On the other hand, tracer tests often require the use of expensive equipment and
many hours in the field of an experienced operator.
The following study has a twofold objective:
i. demonstrate how low-cost and open-source hardware and software can be used to design and
build a field test device that provide accurate field measurements, and
ii. standardize an experimental aquifer test methodology that allows for obtaining reliable
hydrogeological information in a sustainable and cost-effective manner (minimum production of
wastes and minimum employment of field personnel).
2
Single Point Dilution test: principles and methodology
The SPD test provides a direct estimate of the velocity of filtration (vf) in groundwater, by monitoring the
course of a tracer in flows crossing a well until all signs of the tracer have completely disappeared (Settani
A. and Dal Prà A., 1995). The analytical link between the velocity of filtration (vf) and tracer dilution in time,
is provided by the following formula:
[1] 𝑣𝑓 = −
𝑉
𝛼𝐴𝑡
𝑙𝑛
𝐶 𝑡
𝐶0
where V is the volume in which dilution occurs, α is a coefficient to correct the inevitable distortion of the
flow net introduced by the physical structure of the well, A the section of V orthogonal to the flow lines, t is
time, C0 is the concentration in the well at t=0 and Ct the concentration at time t.
From there estimating the effective groundwater velocity is just a matter of dividing Darcy velocity (vf) by
effective porosity (ne):
[2] vr =
vf
ne
and by knowing the hydraulic gradient it is possible to calculate the hydraulic conductivity (K) of the
aquifer.
The test is conducted by injecting a tracer solution, taken at the same temperature as that of the
groundwater, into the well, and measuring the dilution through time at different depths. To ensure a good
homogenization of the solution during the injection phase, the injection tube, usually densely perforated in
correspondence of the well screen interval, is repeatedly withdrawn and reinserted to the bottom of the
well at a very slow and constant speed by an operator.
At the end of the injection period, the operator measures the values of rising electrical conductivity using a
multiparameter probe lowered in the well and manually withdrawn to record with sampling intervals
approximately every 50 cm. Measurements are taken at increasing intervals of time from the end of
injection. The test is completed when the conductivity measured in the well is similar to the one measured
before the injection, and the duration of a test depends on the specific characteristics of the aquifer being
tested.
This procedure has some disadvantages and approximations:
 homogeneous diffusion of the injected solution depends on the way the tubing has been
perforated;
 the operator may induce disturbance to the hydraulic conditions while lowering and withdrawing
the probe, thus mixing the solution and altering the concentrations;
 the operator must be always present to record EC values till the end of the test.
Custom-made electrical conductivity logging device
Down-well multiparameter probes are widely used for monitoring groundwater characteristics at
contaminated sites. However, commercial instruments have a relatively high cost in the order of € 5,000.00
and are usually designed with a single probe – or a bundle of probes (e.g. temperature, ORP, DO, EC and
pH) – that can take measurements at one depth at the time.
Therefore, performing a SPD test with a commercial multiparameter probe means that at least one
operator shall be present for the whole duration of the test in order to lower and withdraw the device and
take readings at the desired depths, and a test could potentially last for days.
3
To address these limitations, in order to minimize the disturbance to the hydraulic conditions and to reduce
the errors induced by manually positioning the device in the well, we decided to build a customized
instrument with specific characteristics:
 the physical-chemical parameters of interest are temperature and electrical conductivity,
 the device shall be able to measure simultaneously at different depths,
 the instrument shall have logging capabilities,
 the device shall be battery powered and easily transportable,
 readings shall be visualized in real-time and remotely.
The down-well part of the system is made of two data cables, one for carrying temperature probes and the
other for the EC probes, each cable being 25 m long. There are 4 EC probes and as many temperature
probes, one-meter spaced, with the technical specifications reported in Table 1.
Table 1 – Specifications of the sensors
Parameter Name Manufacturer Characteristics
Temperature ENV-TEMP-D AtlasScientific LLC
Temperature range: -20 °C to 133 °C
Resolution: XXX.XX
Accuracy: ± 1°C
Submersible
Electrical
Conductivity
Conductivity
Probe
AtlasScientific LLC
Graphite conductors
Cell constant of K 0.1
Measurement range: 0.5 to 50,000 µS/cm
Accuracy: ± 2 µS/cm
Compensated values at 25°C
Submersible
The heart of the system is represented by a Raspberry Pi model B microcomputer, connected to a 12V
battery, equipped with a 3.5” TFT touch display and enclosed within a IP65 box. The Raspberry Pi is a low
cost, credit-card sized Linux board with 26 General Purpose Input/Output (GPIO) pins that can be used as a
physical interface between the Pi and the outside world. The Pi can be programmed in different languages
(among which Python, PHP, HTML and JavaScript were chosen for the case of study) and can easily
interface with actuators and sensors, like temperature and EC probes. AtlasScientific provides fully
integrated interface boards for connecting its environmental probes to the Raspberry Pi, along with
examples of code written in Python.
Following a preliminary testing phase (Figure 1) aimed at evaluating the functionality of the sensors and
comparing the measurements with those provided by standard multiparameter probes (in the specific a
Quanta-G by Hydrolab®), the system was assembled and programmed in-house.
Figure 2 is a picture of the device connected to the EC and temperature probes.
4
Figure 1 – Preliminary testing phase
Figure 2 – SPDT logger connected to the probes in the field
The user interface is represented by a simple HTML page served through a light webserver running on the
Pi itself, equipped with a USB WiFi dongle to provide wireless ad-hoc connectivity (SoftAP mode). The
operator locally connects via WiFi to the system with a WiFi enabled device (e.g. mobile phone, computer
or tablet) in order to view real-time data, set logging parameters and start/stop the system. The same
operations can be performed locally through the touch display, which will display the same HTML page. In
Figure 3 is an example of the user interface.
5
Figure 3 – SPDT logger user interface
Total cost for the construction of the SPD logger is below € 2,000.00. An overall cost estimate can be briefly
summarized as follows.
 #4 EC probes, #4 temperature probes and related circuitry – € 790.00
 200 m of neoprene cables and connectors – € 1,050.00
 Raspberry Pi, 3.5” TFT touch display, box and miscellaneous components – € 130.00
These costs can be easily reduced by purchasing materials in bunches for at least 5 devices.
Field test
The test was conducted at a contaminated site located in Central Italy. Site characterizations activities
carried out few months before, revealed the presence of high concentrations of chlorinated compounds
dissolved in groundwater. The aquifer consists in a layer of gravel and sand about 8 m thick, characterized
by medium to high permeability, laying on a bed of plastic clay located at approximately 10 m below
ground level (bgl), with low permeability. The water table, set at about 3 m bgl, is flowing with a natural
gradient of 0.35 % towards a nearby river, thus posing serious health and environmental risks.
Particularly in such cases when, due to the high permeability of the aquifer, performing standard pumping
test can lead to high costs for handling contaminated purged water (considered as a waste within the
Italian Environmental Framework), the SPD test represents a valid technical and economic alternative.
The test was performed on a monitoring well 10 m deep, completed with a 4” PVC pipe, and screened
between 3 and 9 m bgl, as detailed in Figure 4.
6
Figure 4 – Test well stratigraphic log and completion details
Prior to commence the test, a calibration solution was prepared: 35 grams of sodium chloride (NaCl, the
tracer - Figure 5) were dissolved in 1 litre of groundwater purged from the test well, and the solution
obtained was then progressively diluted with half litre of groundwater to obtain the correlation between
the tracer concentration and the electrical conductivity (Figure 6 and Figure 7). Measurements were taken
using both the low cost probe and the commercial one, in order to verify the accuracy of the system. The
difference between the readings provided by the two probes is in the order of about 4%, thus confirming
the reliability of the custom built device (Table 2).
7
Figure 5 – Preparing the calibration solution of NaCl
Figure 6 – Field test setup
Table 2 – Correlation between tracer concentration and EC
Concentration
[mg/l]
SPDT Logger Quanta-G
Temperature
[°C]
EC [µS/cm]1 Temperature
[°C]
EC [µS/cm]
0.00 (baseline) 15.36 596 15.45 625
35,000.00 14.46 51,483 14.35 51,942
17,500.00 13.73 20,984 14.19 21,618
8,750.00 13.17 10,233 14.11 10,623
4,375.00 12.61 5,572 14.03 5,804
2,187.50 13.73 3,324 13.63 3,463
1,093.75 12.31 1,841 13.58 1,924
546.88 12.18 1,170 13.56 1,224
273.44 12.35 819 13.43 857
1
EC values are normalized to the actual temperature by using the following formula:
𝐸𝐶25 =
𝐸𝐶 𝑇
1 + 𝛿(𝑇 − 25)
where EC25 is the conductivity at 25°C (measured by the probe), ECT is the conductivity at temperature T and δ is a
coefficient assumed equal to 0.0191°C
-1
(from literature)
8
Concentration
[mg/l]
SPDT Logger Quanta-G
Temperature
[°C]
EC [µS/cm]1 Temperature
[°C]
EC [µS/cm]
136.72 12.58 638 13.41 667
68.36 12.37 526 13.42 551
34.18 12.41 478 13.51 501
17.09 12.39 458 12.97 480
8.54 12.75 441 12.93 462
Figure 7 – Calibration curve
After the calibration procedure, a baseline reading was taken directly in the well by positioning the EC and
temperature probes at 8, 7, 6 and 5 m below the wellhead. The logger was started with a recording interval
of 20 seconds, and was left in place while the operator was preparing the tracer solution composed of
about 100 litres (twice the volume of the water within the well) of a saturated solution of sodium chloride
at 4,000 mg/l, corresponding to a conductivity of about 5,500 µS/cm, i.e. about 10 times the baseline value.
Injection into the test well was performed using a battery operated centrifugal pump connected to a PVC
tubing (Ø 22mm) inserted into the well. Every 30 cm the injection tube was equipped with a dripper (Figure
8) auto-compensated to a maximum flow rate of 2 litres per minute.
Figure 8 – Auto-compensated dripper
9
This set up allows for obtaining a good vertical homogenization of the solution without having to manually
mix the solution by repeatedly withdraw and reinsert the injection tube in the well.
Injection into the test well lasted about 11 minutes at a constant flow rate of 9 l/min. During this period the
level to water depth was constantly noted, and a minimal disturbance was observed in the range of few
centimetres (< 2cm). EC and temperature measurements were taken and recorded at the formerly set up
interval of 20 seconds, until the baseline conditions in terms of EC were reinstated. The whole test lasted
about 2 hrs.
Results
Processing of experimental data to estimate the velocity of filtration was carried out starting from equation
[1], which is the equation of a straight line with an angular coefficient:
[3] m =
αAvf
V
= kost ∙ vf
Data were plotted in semi-logarithmic form, and a value for m for each depth sampled was obtained, from
which the corresponding value of vf was derived. Parameter α may generically vary between 0 and 8
(Gaspar, 1987) and in case of wells installed within granular soils without prefilter, it can be given by Ogilvi’s
formula (1958):
[4] α =
4
1+(
r1
r2
)2+
k
k1
[1−(
r1
r2
)2]
in which r1 and r2 are the internal and external radii of the well, and k and k1 are the permeability values of
the aquifer and of the filter respectively. Laboratory tests and many field investigations have in any case
shown that when k1>>k, α tends to be around 2 (Gaspar, 1987).
The overall results are shown in Figure 9, while Table 3 shows values of real velocity (vr) and hydraulic
permeability (K), calculated by assuming α = 2 and ne = 30%.
Table 3 – Filtration and flow velocities and hydraulic permeability
Depth [m]
from wellhead
vf [m/d] vr [m/d] K [m/s]
8 1.85 6.15 6.11E-03
7 1.96 6.54 6.49E-03
6 2.73 9.11 9.04E-03
5 2.27 7.55 7.49E-03
10
Figure 9 – Dilution logs
Results of the test are briefly summarized below.
 In line with what observed during the drilling activities, the aquifer is characterized by a high
hydraulic permeability (gravel and sand).
 Although according to stratigraphic logs the aquifer looks homogeneous, results of the SPD test
provide a better definition and allow for identifying zones with different velocities of filtration.
 The trend of dilution profile at the depth of 6 m shows that this layer, positioned at the middle of
the screened interval, has the highest velocity of filtration.
 Overall the tracer is rapidly and uniformly evacuated.
Conclusions and future improvements
Seeking for an alternative solution to obtain hydrogeological characteristics and minimize the production of
wastes and associated risks, an experimental methodology (the single point dilution method) was
approached. In order to optimize and standardize the procedure for executing such test, a customized EC-
temperature logging device has been designed and developed using open-source hardware and software.
This solution allowed for reducing the costs of instruments supply, minimize the hours in the field of an
experienced operator, and obtain accurate and reliable data that can be used to build groundwater
remediation activities.
The custom-built device can be easily adapted to different test conditions. Further improvements include
 the implementation of a single cable for each sensor, allowing for positioning each probe at a
desired depth and not limiting the recording interval to 1 m,
 the addition of a GPRS module for complete remote connectivity,
 the possibility to use different probes, such as ORP, pH and DO to measure other chemical-physical
parameters.
Nowadays, given the accessibility of low-cost environmental sensors and open-source technologies,
building innovative and cost-effective devices on which rely to improve the design of remediation activities
is just a matter of time.
11
References
Halevy E., Moser H., Zellhofer O. & Zuber A. (1967) Borehole dilution techniques: A critical review.
Proceedings of the Symposium on Isotopes in Hydrology, pp. 531-564 IAEA, Vienna, Austria.
Hulla J, Ravinger R. & Turcek P. (1982) Radio-indicator tests in hydrogeological boreholes. Bulletin of
Engineering Geology and the Environment Volume 26-27 n.1, 1982 pp. 439-442.
Gaspar E. (1987) Modern trends in tracer hydrology. CRC Press, Florida.
Ogilvi, N.A. (1958) Electrolytic method for the determination of the ground water filtration velocity. Bulletin
of Science and Technology News, n. 4 (16), Moscow, Russia: Gosgeoltehizdat.
Sottani A. & Dal Prà A. (1995) Misure di velocità di deflusso delle acque sotterranee con il metodo della
diluizione puntuale in un sito campione dell’alta pianura veneta - Galliera V. Italia Settentrionale. 2°
I.M.Y.R.A.G. International Meeting for Young Researchers in Applied Geology (11-13 October 1995),
Peveragno (CN).
Lamontagne S., Dighton J., and Ullman W. (2002) Estimation of groundwater velocity in riparian zones using
point dilution tests CSIRO Land and Water Technical Report 14/02
Pitrak M., Mares S. and Kobr M. (2007) A Simple Borehole Dilution Technique in Measuring Horizontal
Ground Water Flow Vol. 45, No. 1 – GROUND WATER – January-Ferbuary 2007 (pages 89-92).
Ma R., McBratney A., Whelan B., Minasny B., Short M. (2010) Comparing temperature correction models for
soil electrical conductivity measurement Springer Science+Business Media, LLC 2010.
Stahl M.O., Ong J.B., Harvey C.F., Johnson C.D., Badruzzaman A.B.M., Tarek M.H., van Green A., Anderson
J.A., and Lane J.W. (2013) Detecting well casing leaks in Bangladesh using a salt spiking method National
Ground Water Association.

Weitere ähnliche Inhalte

Was ist angesagt?

DSD-INT 2018 A Methodology Study for Model Build and Calibration of 2D Hydrod...
DSD-INT 2018 A Methodology Study for Model Build and Calibration of 2D Hydrod...DSD-INT 2018 A Methodology Study for Model Build and Calibration of 2D Hydrod...
DSD-INT 2018 A Methodology Study for Model Build and Calibration of 2D Hydrod...Deltares
 
Westbay Nova Product Brochure 2015
Westbay Nova Product Brochure 2015Westbay Nova Product Brochure 2015
Westbay Nova Product Brochure 2015Nathan Lopez
 
Proficiency testing - implementing QA/QC standards in laboratory networks; Ex...
Proficiency testing - implementing QA/QC standards in laboratory networks; Ex...Proficiency testing - implementing QA/QC standards in laboratory networks; Ex...
Proficiency testing - implementing QA/QC standards in laboratory networks; Ex...ExternalEvents
 
PIOGA/MSC Observations/Questions on PA DEP Radiation in Shale Drilling Study
PIOGA/MSC Observations/Questions on PA DEP Radiation in Shale Drilling StudyPIOGA/MSC Observations/Questions on PA DEP Radiation in Shale Drilling Study
PIOGA/MSC Observations/Questions on PA DEP Radiation in Shale Drilling StudyMarcellus Drilling News
 
Mod10 11 part1
Mod10 11 part1Mod10 11 part1
Mod10 11 part1Sri Ram
 
Improving Remedial Actions Through Integrated Use of Direct-Push HRSC Technol...
Improving Remedial Actions Through Integrated Use of Direct-Push HRSC Technol...Improving Remedial Actions Through Integrated Use of Direct-Push HRSC Technol...
Improving Remedial Actions Through Integrated Use of Direct-Push HRSC Technol...ASC-HRSC
 
Leakage detection in water pipe networks using Ground Penetrating Radar (GPR)...
Leakage detection in water pipe networks using Ground Penetrating Radar (GPR)...Leakage detection in water pipe networks using Ground Penetrating Radar (GPR)...
Leakage detection in water pipe networks using Ground Penetrating Radar (GPR)...Dai Shi
 
HRSC Technologies: Using MiHpt for Rapid In-Situ Contaminant and Hydrostratig...
HRSC Technologies: Using MiHpt for Rapid In-Situ Contaminant and Hydrostratig...HRSC Technologies: Using MiHpt for Rapid In-Situ Contaminant and Hydrostratig...
HRSC Technologies: Using MiHpt for Rapid In-Situ Contaminant and Hydrostratig...ASC-HRSC
 
Cathodic Protection for Above Ground Storage Tanks (AGSTs)
Cathodic Protection for Above Ground Storage Tanks (AGSTs) Cathodic Protection for Above Ground Storage Tanks (AGSTs)
Cathodic Protection for Above Ground Storage Tanks (AGSTs) Audubon Engineering Company
 
Final Newea 9 09 10 Mh Rehab
Final Newea 9 09 10 Mh RehabFinal Newea 9 09 10 Mh Rehab
Final Newea 9 09 10 Mh Rehabmfrench62
 
Download-manuals-ground water-manual-gw-volume4fieldmanualgeo-hydrologypartiii
 Download-manuals-ground water-manual-gw-volume4fieldmanualgeo-hydrologypartiii Download-manuals-ground water-manual-gw-volume4fieldmanualgeo-hydrologypartiii
Download-manuals-ground water-manual-gw-volume4fieldmanualgeo-hydrologypartiiihydrologyproject001
 
Automatic carbon dioxide methane gas sensor based on the solubility of gases ...
Automatic carbon dioxide methane gas sensor based on the solubility of gases ...Automatic carbon dioxide methane gas sensor based on the solubility of gases ...
Automatic carbon dioxide methane gas sensor based on the solubility of gases ...Sherry Huang
 
Datalogger error introductory course
Datalogger error introductory courseDatalogger error introductory course
Datalogger error introductory courseHydroG Resources
 
DSD-INT 2015 - The river basin explorer – Marieke Fennema, Witteveen+Bos, Cla...
DSD-INT 2015 - The river basin explorer – Marieke Fennema, Witteveen+Bos, Cla...DSD-INT 2015 - The river basin explorer – Marieke Fennema, Witteveen+Bos, Cla...
DSD-INT 2015 - The river basin explorer – Marieke Fennema, Witteveen+Bos, Cla...Deltares
 
ISO/TC 190 - Soil Quality
ISO/TC 190 - Soil QualityISO/TC 190 - Soil Quality
ISO/TC 190 - Soil QualityExternalEvents
 
Pipeline leak detection system
Pipeline leak detection systemPipeline leak detection system
Pipeline leak detection systemAbhijeet Malhotra
 
Basic Manual Water Level Measurement
Basic Manual Water Level MeasurementBasic Manual Water Level Measurement
Basic Manual Water Level MeasurementHydroG Resources
 
Quality Assurance program and interlaboratory comparisons within the UN/ECE I...
Quality Assurance program and interlaboratory comparisons within the UN/ECE I...Quality Assurance program and interlaboratory comparisons within the UN/ECE I...
Quality Assurance program and interlaboratory comparisons within the UN/ECE I...ExternalEvents
 
IMPROVED RESERVOIR EVALUATION 
IMPROVED RESERVOIR EVALUATION IMPROVED RESERVOIR EVALUATION 
IMPROVED RESERVOIR EVALUATION Modou.L. Jarju
 

Was ist angesagt? (20)

DSD-INT 2018 A Methodology Study for Model Build and Calibration of 2D Hydrod...
DSD-INT 2018 A Methodology Study for Model Build and Calibration of 2D Hydrod...DSD-INT 2018 A Methodology Study for Model Build and Calibration of 2D Hydrod...
DSD-INT 2018 A Methodology Study for Model Build and Calibration of 2D Hydrod...
 
Westbay Nova Product Brochure 2015
Westbay Nova Product Brochure 2015Westbay Nova Product Brochure 2015
Westbay Nova Product Brochure 2015
 
Proficiency testing - implementing QA/QC standards in laboratory networks; Ex...
Proficiency testing - implementing QA/QC standards in laboratory networks; Ex...Proficiency testing - implementing QA/QC standards in laboratory networks; Ex...
Proficiency testing - implementing QA/QC standards in laboratory networks; Ex...
 
PIOGA/MSC Observations/Questions on PA DEP Radiation in Shale Drilling Study
PIOGA/MSC Observations/Questions on PA DEP Radiation in Shale Drilling StudyPIOGA/MSC Observations/Questions on PA DEP Radiation in Shale Drilling Study
PIOGA/MSC Observations/Questions on PA DEP Radiation in Shale Drilling Study
 
Mod10 11 part1
Mod10 11 part1Mod10 11 part1
Mod10 11 part1
 
Improving Remedial Actions Through Integrated Use of Direct-Push HRSC Technol...
Improving Remedial Actions Through Integrated Use of Direct-Push HRSC Technol...Improving Remedial Actions Through Integrated Use of Direct-Push HRSC Technol...
Improving Remedial Actions Through Integrated Use of Direct-Push HRSC Technol...
 
Leakage detection in water pipe networks using Ground Penetrating Radar (GPR)...
Leakage detection in water pipe networks using Ground Penetrating Radar (GPR)...Leakage detection in water pipe networks using Ground Penetrating Radar (GPR)...
Leakage detection in water pipe networks using Ground Penetrating Radar (GPR)...
 
HRSC Technologies: Using MiHpt for Rapid In-Situ Contaminant and Hydrostratig...
HRSC Technologies: Using MiHpt for Rapid In-Situ Contaminant and Hydrostratig...HRSC Technologies: Using MiHpt for Rapid In-Situ Contaminant and Hydrostratig...
HRSC Technologies: Using MiHpt for Rapid In-Situ Contaminant and Hydrostratig...
 
Cathodic Protection for Above Ground Storage Tanks (AGSTs)
Cathodic Protection for Above Ground Storage Tanks (AGSTs) Cathodic Protection for Above Ground Storage Tanks (AGSTs)
Cathodic Protection for Above Ground Storage Tanks (AGSTs)
 
Final Newea 9 09 10 Mh Rehab
Final Newea 9 09 10 Mh RehabFinal Newea 9 09 10 Mh Rehab
Final Newea 9 09 10 Mh Rehab
 
ICOS ATC Labeling Process
ICOS ATC Labeling ProcessICOS ATC Labeling Process
ICOS ATC Labeling Process
 
Download-manuals-ground water-manual-gw-volume4fieldmanualgeo-hydrologypartiii
 Download-manuals-ground water-manual-gw-volume4fieldmanualgeo-hydrologypartiii Download-manuals-ground water-manual-gw-volume4fieldmanualgeo-hydrologypartiii
Download-manuals-ground water-manual-gw-volume4fieldmanualgeo-hydrologypartiii
 
Automatic carbon dioxide methane gas sensor based on the solubility of gases ...
Automatic carbon dioxide methane gas sensor based on the solubility of gases ...Automatic carbon dioxide methane gas sensor based on the solubility of gases ...
Automatic carbon dioxide methane gas sensor based on the solubility of gases ...
 
Datalogger error introductory course
Datalogger error introductory courseDatalogger error introductory course
Datalogger error introductory course
 
DSD-INT 2015 - The river basin explorer – Marieke Fennema, Witteveen+Bos, Cla...
DSD-INT 2015 - The river basin explorer – Marieke Fennema, Witteveen+Bos, Cla...DSD-INT 2015 - The river basin explorer – Marieke Fennema, Witteveen+Bos, Cla...
DSD-INT 2015 - The river basin explorer – Marieke Fennema, Witteveen+Bos, Cla...
 
ISO/TC 190 - Soil Quality
ISO/TC 190 - Soil QualityISO/TC 190 - Soil Quality
ISO/TC 190 - Soil Quality
 
Pipeline leak detection system
Pipeline leak detection systemPipeline leak detection system
Pipeline leak detection system
 
Basic Manual Water Level Measurement
Basic Manual Water Level MeasurementBasic Manual Water Level Measurement
Basic Manual Water Level Measurement
 
Quality Assurance program and interlaboratory comparisons within the UN/ECE I...
Quality Assurance program and interlaboratory comparisons within the UN/ECE I...Quality Assurance program and interlaboratory comparisons within the UN/ECE I...
Quality Assurance program and interlaboratory comparisons within the UN/ECE I...
 
IMPROVED RESERVOIR EVALUATION 
IMPROVED RESERVOIR EVALUATION IMPROVED RESERVOIR EVALUATION 
IMPROVED RESERVOIR EVALUATION 
 

Andere mochten auch (20)

Marketing review
Marketing reviewMarketing review
Marketing review
 
Jeroen Kraan - CV in brief
Jeroen Kraan - CV in briefJeroen Kraan - CV in brief
Jeroen Kraan - CV in brief
 
Tracking CIM-iGIP
Tracking CIM-iGIPTracking CIM-iGIP
Tracking CIM-iGIP
 
How Developers’ Collaborations Identified from Different Sources Tell us Abou...
How Developers’ Collaborations Identified from Different Sources Tell us Abou...How Developers’ Collaborations Identified from Different Sources Tell us Abou...
How Developers’ Collaborations Identified from Different Sources Tell us Abou...
 
Constraints
ConstraintsConstraints
Constraints
 
Im and o '13 april lc day review
Im and o '13 april lc day reviewIm and o '13 april lc day review
Im and o '13 april lc day review
 
Bd er '13 april lc day review
Bd  er '13 april lc day reviewBd  er '13 april lc day review
Bd er '13 april lc day review
 
Sona
SonaSona
Sona
 
Xecutive authority
Xecutive authorityXecutive authority
Xecutive authority
 
Sofa
SofaSofa
Sofa
 
Gbm sofa 15th sept
Gbm sofa 15th septGbm sofa 15th sept
Gbm sofa 15th sept
 
Vistaar
VistaarVistaar
Vistaar
 
Xd review main
Xd review mainXd review main
Xd review main
 
Sneha
SnehaSneha
Sneha
 
Spartans
SpartansSpartans
Spartans
 
Digital Economy, SocialCommerce and MIT Open Courseware
Digital Economy, SocialCommerce and MIT Open Courseware Digital Economy, SocialCommerce and MIT Open Courseware
Digital Economy, SocialCommerce and MIT Open Courseware
 
Gcdp lc day
Gcdp lc dayGcdp lc day
Gcdp lc day
 
Sola
SolaSola
Sola
 
Production log
Production logProduction log
Production log
 
Mi familia y yo
Mi familia y yoMi familia y yo
Mi familia y yo
 

Ähnlich wie The role of open source technology based equipment in developing reliablereliable, customizable and cost-effective aquifer model for site remediation

WATER LEVEL DETECTOR WITH TURBIDITY SENSOR
WATER LEVEL DETECTOR WITH TURBIDITY SENSORWATER LEVEL DETECTOR WITH TURBIDITY SENSOR
WATER LEVEL DETECTOR WITH TURBIDITY SENSORdeepa bhatia
 
Prototype SMS Based Fluid Parameter monitoring system.pptx
Prototype SMS Based Fluid Parameter monitoring system.pptxPrototype SMS Based Fluid Parameter monitoring system.pptx
Prototype SMS Based Fluid Parameter monitoring system.pptxLoisDavid2
 
SENSOR NETWORK FOR REAL‐TIME MONITORING AND DETECTION CONTAMINATION IN DRINKI...
SENSOR NETWORK FOR REAL‐TIME MONITORING AND DETECTION CONTAMINATION IN DRINKI...SENSOR NETWORK FOR REAL‐TIME MONITORING AND DETECTION CONTAMINATION IN DRINKI...
SENSOR NETWORK FOR REAL‐TIME MONITORING AND DETECTION CONTAMINATION IN DRINKI...ijiert bestjournal
 
Fredrick Ishengoma - A Novel Design of IEEE 802.15.4 and Solar Based Autonomo...
Fredrick Ishengoma - A Novel Design of IEEE 802.15.4 and Solar Based Autonomo...Fredrick Ishengoma - A Novel Design of IEEE 802.15.4 and Solar Based Autonomo...
Fredrick Ishengoma - A Novel Design of IEEE 802.15.4 and Solar Based Autonomo...Fredrick Ishengoma
 
portable_flow_measurement-pr-en PES Scotland NIVUS
portable_flow_measurement-pr-en PES Scotland NIVUSportable_flow_measurement-pr-en PES Scotland NIVUS
portable_flow_measurement-pr-en PES Scotland NIVUSDavid White
 
Hydrologic Monitoring Network Questionnaire
Hydrologic Monitoring Network QuestionnaireHydrologic Monitoring Network Questionnaire
Hydrologic Monitoring Network Questionnaireindiawrm
 
Online Monitoring of Wastewater in Common Effluent Treatment Plant using UV-V...
Online Monitoring of Wastewater in Common Effluent Treatment Plant using UV-V...Online Monitoring of Wastewater in Common Effluent Treatment Plant using UV-V...
Online Monitoring of Wastewater in Common Effluent Treatment Plant using UV-V...Mudasir Gulzar
 
Capacitive electrode sensor implanted on a printed circuit board designed for...
Capacitive electrode sensor implanted on a printed circuit board designed for...Capacitive electrode sensor implanted on a printed circuit board designed for...
Capacitive electrode sensor implanted on a printed circuit board designed for...journalBEEI
 
Experimental and Computational Fluid Dynamics (CFD) Analysis of Additively Ma...
Experimental and Computational Fluid Dynamics (CFD) Analysis of Additively Ma...Experimental and Computational Fluid Dynamics (CFD) Analysis of Additively Ma...
Experimental and Computational Fluid Dynamics (CFD) Analysis of Additively Ma...IRJET Journal
 
Machine Learning Classification to predict water purity based on Viruses and ...
Machine Learning Classification to predict water purity based on Viruses and ...Machine Learning Classification to predict water purity based on Viruses and ...
Machine Learning Classification to predict water purity based on Viruses and ...CloudTechnologies
 
A Smart Flow Measurement System Adaptive to Different Variation Using Ultraso...
A Smart Flow Measurement System Adaptive to Different Variation Using Ultraso...A Smart Flow Measurement System Adaptive to Different Variation Using Ultraso...
A Smart Flow Measurement System Adaptive to Different Variation Using Ultraso...Sheikh R Manihar Ahmed
 
prasad m r technical seminar.pptx
prasad m r technical seminar.pptxprasad m r technical seminar.pptx
prasad m r technical seminar.pptxVanshGupta396933
 
IRJET- Experimental Study on Flow through Venturimeter
IRJET- Experimental Study on Flow through VenturimeterIRJET- Experimental Study on Flow through Venturimeter
IRJET- Experimental Study on Flow through VenturimeterIRJET Journal
 
DSD-INT 2014 - OpenMI Symposium - A selection of water-related applications o...
DSD-INT 2014 - OpenMI Symposium - A selection of water-related applications o...DSD-INT 2014 - OpenMI Symposium - A selection of water-related applications o...
DSD-INT 2014 - OpenMI Symposium - A selection of water-related applications o...Deltares
 
Numerical analysis for two phase flow distribution headers in heat exchangers
Numerical analysis for two phase flow distribution headers in heat exchangersNumerical analysis for two phase flow distribution headers in heat exchangers
Numerical analysis for two phase flow distribution headers in heat exchangerseSAT Journals
 
Agr Field Operations Pipeline Inspection
Agr Field Operations Pipeline InspectionAgr Field Operations Pipeline Inspection
Agr Field Operations Pipeline Inspectionjsthetford
 
tanmoy new 2022.docx
tanmoy new 2022.docxtanmoy new 2022.docx
tanmoy new 2022.docxFirecubexOli
 
Flow Field Measurements in a Large Controlled Ventilated Room
Flow Field Measurements in a Large Controlled Ventilated RoomFlow Field Measurements in a Large Controlled Ventilated Room
Flow Field Measurements in a Large Controlled Ventilated RoomIRJET Journal
 

Ähnlich wie The role of open source technology based equipment in developing reliablereliable, customizable and cost-effective aquifer model for site remediation (20)

WATER LEVEL DETECTOR WITH TURBIDITY SENSOR
WATER LEVEL DETECTOR WITH TURBIDITY SENSORWATER LEVEL DETECTOR WITH TURBIDITY SENSOR
WATER LEVEL DETECTOR WITH TURBIDITY SENSOR
 
Prototype SMS Based Fluid Parameter monitoring system.pptx
Prototype SMS Based Fluid Parameter monitoring system.pptxPrototype SMS Based Fluid Parameter monitoring system.pptx
Prototype SMS Based Fluid Parameter monitoring system.pptx
 
SENSOR NETWORK FOR REAL‐TIME MONITORING AND DETECTION CONTAMINATION IN DRINKI...
SENSOR NETWORK FOR REAL‐TIME MONITORING AND DETECTION CONTAMINATION IN DRINKI...SENSOR NETWORK FOR REAL‐TIME MONITORING AND DETECTION CONTAMINATION IN DRINKI...
SENSOR NETWORK FOR REAL‐TIME MONITORING AND DETECTION CONTAMINATION IN DRINKI...
 
Fredrick Ishengoma - A Novel Design of IEEE 802.15.4 and Solar Based Autonomo...
Fredrick Ishengoma - A Novel Design of IEEE 802.15.4 and Solar Based Autonomo...Fredrick Ishengoma - A Novel Design of IEEE 802.15.4 and Solar Based Autonomo...
Fredrick Ishengoma - A Novel Design of IEEE 802.15.4 and Solar Based Autonomo...
 
portable_flow_measurement-pr-en PES Scotland NIVUS
portable_flow_measurement-pr-en PES Scotland NIVUSportable_flow_measurement-pr-en PES Scotland NIVUS
portable_flow_measurement-pr-en PES Scotland NIVUS
 
Hydrologic Monitoring Network Questionnaire
Hydrologic Monitoring Network QuestionnaireHydrologic Monitoring Network Questionnaire
Hydrologic Monitoring Network Questionnaire
 
ise sensor
ise sensorise sensor
ise sensor
 
Online Monitoring of Wastewater in Common Effluent Treatment Plant using UV-V...
Online Monitoring of Wastewater in Common Effluent Treatment Plant using UV-V...Online Monitoring of Wastewater in Common Effluent Treatment Plant using UV-V...
Online Monitoring of Wastewater in Common Effluent Treatment Plant using UV-V...
 
Capacitive electrode sensor implanted on a printed circuit board designed for...
Capacitive electrode sensor implanted on a printed circuit board designed for...Capacitive electrode sensor implanted on a printed circuit board designed for...
Capacitive electrode sensor implanted on a printed circuit board designed for...
 
INCENDIA
INCENDIAINCENDIA
INCENDIA
 
Experimental and Computational Fluid Dynamics (CFD) Analysis of Additively Ma...
Experimental and Computational Fluid Dynamics (CFD) Analysis of Additively Ma...Experimental and Computational Fluid Dynamics (CFD) Analysis of Additively Ma...
Experimental and Computational Fluid Dynamics (CFD) Analysis of Additively Ma...
 
Machine Learning Classification to predict water purity based on Viruses and ...
Machine Learning Classification to predict water purity based on Viruses and ...Machine Learning Classification to predict water purity based on Viruses and ...
Machine Learning Classification to predict water purity based on Viruses and ...
 
A Smart Flow Measurement System Adaptive to Different Variation Using Ultraso...
A Smart Flow Measurement System Adaptive to Different Variation Using Ultraso...A Smart Flow Measurement System Adaptive to Different Variation Using Ultraso...
A Smart Flow Measurement System Adaptive to Different Variation Using Ultraso...
 
prasad m r technical seminar.pptx
prasad m r technical seminar.pptxprasad m r technical seminar.pptx
prasad m r technical seminar.pptx
 
IRJET- Experimental Study on Flow through Venturimeter
IRJET- Experimental Study on Flow through VenturimeterIRJET- Experimental Study on Flow through Venturimeter
IRJET- Experimental Study on Flow through Venturimeter
 
DSD-INT 2014 - OpenMI Symposium - A selection of water-related applications o...
DSD-INT 2014 - OpenMI Symposium - A selection of water-related applications o...DSD-INT 2014 - OpenMI Symposium - A selection of water-related applications o...
DSD-INT 2014 - OpenMI Symposium - A selection of water-related applications o...
 
Numerical analysis for two phase flow distribution headers in heat exchangers
Numerical analysis for two phase flow distribution headers in heat exchangersNumerical analysis for two phase flow distribution headers in heat exchangers
Numerical analysis for two phase flow distribution headers in heat exchangers
 
Agr Field Operations Pipeline Inspection
Agr Field Operations Pipeline InspectionAgr Field Operations Pipeline Inspection
Agr Field Operations Pipeline Inspection
 
tanmoy new 2022.docx
tanmoy new 2022.docxtanmoy new 2022.docx
tanmoy new 2022.docx
 
Flow Field Measurements in a Large Controlled Ventilated Room
Flow Field Measurements in a Large Controlled Ventilated RoomFlow Field Measurements in a Large Controlled Ventilated Room
Flow Field Measurements in a Large Controlled Ventilated Room
 

The role of open source technology based equipment in developing reliablereliable, customizable and cost-effective aquifer model for site remediation

  • 1. 1 The role of open source technology based equipment in developing reliable, customizable and cost- effective aquifer model for site remediation by Campioni A., Losi P., Angelozzi I., and Santoro L. B. Abstract Improving the understanding of the conceptual model of a contaminated site, is key to increase the efficiency of the remediation techniques to apply. In particular, with regard to the contaminated groundwater, a reliable reconstruction of the aquifer’s structure is important to develop a numerical model of the site and identify contaminants transport pathways and fate, since the mass flux is predominant through the most permeable layers. Aquifers characterization traditionally make use of aquifer pumping tests and is often expensive and unsustainable since it involves management and disposal of large amounts of potentially contaminated water. It also requires the employment of one or more field operators to correctly carry out the tests. Therefore, the tendency is to develop tests that do not involve pumping of large volumes of water and provide in-depth details of aquifer’s characteristics. An experimental methodology for the direct measurement of the groundwater filtration velocity and implying a low-cost, down-well electrical conductivity logging device was developed for data acquisition during a single point dilution test (SPD test). The electrical conductivity logging device used to perform the test was designed and assembled in-house in order to meet the specific needs related to the field test protocol and investigation scopes: it is lightweight, can be remotely controlled and operable by one person. The present paper summarizes the results of a SPD test performed on a monitoring well installed in a contaminated site in Central Italy, and demonstrates the advantages of a versatile device specifically designed and built for the test needs. The device has proved to produce extremely reliable and accurate data that can be used to improve the conceptual site model for designing site remediation activities. Moreover the device can be built with minimal cost by using open source hardware and software, therefore implying more flexibility also in case of changes required to adapt the device to the particular set-up of one or more field tests. The article also includes an evaluation of the specific technology for future enhancement of the system that can make it even more versatile and cost-effective. Introduction A numerical model is necessary to design effective and efficient remediation activities. It is used for understanding the hydrogeological system and its behaviour, and for predicting its response to any stress applied to it. The effectiveness of a groundwater numerical model in representing the real world is strongly dependent on the goodness of the data used to build it. Hence being able to collect reliable data in a cost- effective way is nowadays a key aspect for any remediation design. Performing aquifer pumping tests in a contaminated environment has always posed several difficulties and risks, e.g. production of wastes, health and safety risks due to handling contaminated water, etc., while quick aquifer tests (e.g. slug tests), not involving pumping of contaminated groundwater, do not always provide reliable results. On the other hand, tracer tests often require the use of expensive equipment and many hours in the field of an experienced operator. The following study has a twofold objective: i. demonstrate how low-cost and open-source hardware and software can be used to design and build a field test device that provide accurate field measurements, and ii. standardize an experimental aquifer test methodology that allows for obtaining reliable hydrogeological information in a sustainable and cost-effective manner (minimum production of wastes and minimum employment of field personnel).
  • 2. 2 Single Point Dilution test: principles and methodology The SPD test provides a direct estimate of the velocity of filtration (vf) in groundwater, by monitoring the course of a tracer in flows crossing a well until all signs of the tracer have completely disappeared (Settani A. and Dal Prà A., 1995). The analytical link between the velocity of filtration (vf) and tracer dilution in time, is provided by the following formula: [1] 𝑣𝑓 = − 𝑉 𝛼𝐴𝑡 𝑙𝑛 𝐶 𝑡 𝐶0 where V is the volume in which dilution occurs, α is a coefficient to correct the inevitable distortion of the flow net introduced by the physical structure of the well, A the section of V orthogonal to the flow lines, t is time, C0 is the concentration in the well at t=0 and Ct the concentration at time t. From there estimating the effective groundwater velocity is just a matter of dividing Darcy velocity (vf) by effective porosity (ne): [2] vr = vf ne and by knowing the hydraulic gradient it is possible to calculate the hydraulic conductivity (K) of the aquifer. The test is conducted by injecting a tracer solution, taken at the same temperature as that of the groundwater, into the well, and measuring the dilution through time at different depths. To ensure a good homogenization of the solution during the injection phase, the injection tube, usually densely perforated in correspondence of the well screen interval, is repeatedly withdrawn and reinserted to the bottom of the well at a very slow and constant speed by an operator. At the end of the injection period, the operator measures the values of rising electrical conductivity using a multiparameter probe lowered in the well and manually withdrawn to record with sampling intervals approximately every 50 cm. Measurements are taken at increasing intervals of time from the end of injection. The test is completed when the conductivity measured in the well is similar to the one measured before the injection, and the duration of a test depends on the specific characteristics of the aquifer being tested. This procedure has some disadvantages and approximations:  homogeneous diffusion of the injected solution depends on the way the tubing has been perforated;  the operator may induce disturbance to the hydraulic conditions while lowering and withdrawing the probe, thus mixing the solution and altering the concentrations;  the operator must be always present to record EC values till the end of the test. Custom-made electrical conductivity logging device Down-well multiparameter probes are widely used for monitoring groundwater characteristics at contaminated sites. However, commercial instruments have a relatively high cost in the order of € 5,000.00 and are usually designed with a single probe – or a bundle of probes (e.g. temperature, ORP, DO, EC and pH) – that can take measurements at one depth at the time. Therefore, performing a SPD test with a commercial multiparameter probe means that at least one operator shall be present for the whole duration of the test in order to lower and withdraw the device and take readings at the desired depths, and a test could potentially last for days.
  • 3. 3 To address these limitations, in order to minimize the disturbance to the hydraulic conditions and to reduce the errors induced by manually positioning the device in the well, we decided to build a customized instrument with specific characteristics:  the physical-chemical parameters of interest are temperature and electrical conductivity,  the device shall be able to measure simultaneously at different depths,  the instrument shall have logging capabilities,  the device shall be battery powered and easily transportable,  readings shall be visualized in real-time and remotely. The down-well part of the system is made of two data cables, one for carrying temperature probes and the other for the EC probes, each cable being 25 m long. There are 4 EC probes and as many temperature probes, one-meter spaced, with the technical specifications reported in Table 1. Table 1 – Specifications of the sensors Parameter Name Manufacturer Characteristics Temperature ENV-TEMP-D AtlasScientific LLC Temperature range: -20 °C to 133 °C Resolution: XXX.XX Accuracy: ± 1°C Submersible Electrical Conductivity Conductivity Probe AtlasScientific LLC Graphite conductors Cell constant of K 0.1 Measurement range: 0.5 to 50,000 µS/cm Accuracy: ± 2 µS/cm Compensated values at 25°C Submersible The heart of the system is represented by a Raspberry Pi model B microcomputer, connected to a 12V battery, equipped with a 3.5” TFT touch display and enclosed within a IP65 box. The Raspberry Pi is a low cost, credit-card sized Linux board with 26 General Purpose Input/Output (GPIO) pins that can be used as a physical interface between the Pi and the outside world. The Pi can be programmed in different languages (among which Python, PHP, HTML and JavaScript were chosen for the case of study) and can easily interface with actuators and sensors, like temperature and EC probes. AtlasScientific provides fully integrated interface boards for connecting its environmental probes to the Raspberry Pi, along with examples of code written in Python. Following a preliminary testing phase (Figure 1) aimed at evaluating the functionality of the sensors and comparing the measurements with those provided by standard multiparameter probes (in the specific a Quanta-G by Hydrolab®), the system was assembled and programmed in-house. Figure 2 is a picture of the device connected to the EC and temperature probes.
  • 4. 4 Figure 1 – Preliminary testing phase Figure 2 – SPDT logger connected to the probes in the field The user interface is represented by a simple HTML page served through a light webserver running on the Pi itself, equipped with a USB WiFi dongle to provide wireless ad-hoc connectivity (SoftAP mode). The operator locally connects via WiFi to the system with a WiFi enabled device (e.g. mobile phone, computer or tablet) in order to view real-time data, set logging parameters and start/stop the system. The same operations can be performed locally through the touch display, which will display the same HTML page. In Figure 3 is an example of the user interface.
  • 5. 5 Figure 3 – SPDT logger user interface Total cost for the construction of the SPD logger is below € 2,000.00. An overall cost estimate can be briefly summarized as follows.  #4 EC probes, #4 temperature probes and related circuitry – € 790.00  200 m of neoprene cables and connectors – € 1,050.00  Raspberry Pi, 3.5” TFT touch display, box and miscellaneous components – € 130.00 These costs can be easily reduced by purchasing materials in bunches for at least 5 devices. Field test The test was conducted at a contaminated site located in Central Italy. Site characterizations activities carried out few months before, revealed the presence of high concentrations of chlorinated compounds dissolved in groundwater. The aquifer consists in a layer of gravel and sand about 8 m thick, characterized by medium to high permeability, laying on a bed of plastic clay located at approximately 10 m below ground level (bgl), with low permeability. The water table, set at about 3 m bgl, is flowing with a natural gradient of 0.35 % towards a nearby river, thus posing serious health and environmental risks. Particularly in such cases when, due to the high permeability of the aquifer, performing standard pumping test can lead to high costs for handling contaminated purged water (considered as a waste within the Italian Environmental Framework), the SPD test represents a valid technical and economic alternative. The test was performed on a monitoring well 10 m deep, completed with a 4” PVC pipe, and screened between 3 and 9 m bgl, as detailed in Figure 4.
  • 6. 6 Figure 4 – Test well stratigraphic log and completion details Prior to commence the test, a calibration solution was prepared: 35 grams of sodium chloride (NaCl, the tracer - Figure 5) were dissolved in 1 litre of groundwater purged from the test well, and the solution obtained was then progressively diluted with half litre of groundwater to obtain the correlation between the tracer concentration and the electrical conductivity (Figure 6 and Figure 7). Measurements were taken using both the low cost probe and the commercial one, in order to verify the accuracy of the system. The difference between the readings provided by the two probes is in the order of about 4%, thus confirming the reliability of the custom built device (Table 2).
  • 7. 7 Figure 5 – Preparing the calibration solution of NaCl Figure 6 – Field test setup Table 2 – Correlation between tracer concentration and EC Concentration [mg/l] SPDT Logger Quanta-G Temperature [°C] EC [µS/cm]1 Temperature [°C] EC [µS/cm] 0.00 (baseline) 15.36 596 15.45 625 35,000.00 14.46 51,483 14.35 51,942 17,500.00 13.73 20,984 14.19 21,618 8,750.00 13.17 10,233 14.11 10,623 4,375.00 12.61 5,572 14.03 5,804 2,187.50 13.73 3,324 13.63 3,463 1,093.75 12.31 1,841 13.58 1,924 546.88 12.18 1,170 13.56 1,224 273.44 12.35 819 13.43 857 1 EC values are normalized to the actual temperature by using the following formula: 𝐸𝐶25 = 𝐸𝐶 𝑇 1 + 𝛿(𝑇 − 25) where EC25 is the conductivity at 25°C (measured by the probe), ECT is the conductivity at temperature T and δ is a coefficient assumed equal to 0.0191°C -1 (from literature)
  • 8. 8 Concentration [mg/l] SPDT Logger Quanta-G Temperature [°C] EC [µS/cm]1 Temperature [°C] EC [µS/cm] 136.72 12.58 638 13.41 667 68.36 12.37 526 13.42 551 34.18 12.41 478 13.51 501 17.09 12.39 458 12.97 480 8.54 12.75 441 12.93 462 Figure 7 – Calibration curve After the calibration procedure, a baseline reading was taken directly in the well by positioning the EC and temperature probes at 8, 7, 6 and 5 m below the wellhead. The logger was started with a recording interval of 20 seconds, and was left in place while the operator was preparing the tracer solution composed of about 100 litres (twice the volume of the water within the well) of a saturated solution of sodium chloride at 4,000 mg/l, corresponding to a conductivity of about 5,500 µS/cm, i.e. about 10 times the baseline value. Injection into the test well was performed using a battery operated centrifugal pump connected to a PVC tubing (Ø 22mm) inserted into the well. Every 30 cm the injection tube was equipped with a dripper (Figure 8) auto-compensated to a maximum flow rate of 2 litres per minute. Figure 8 – Auto-compensated dripper
  • 9. 9 This set up allows for obtaining a good vertical homogenization of the solution without having to manually mix the solution by repeatedly withdraw and reinsert the injection tube in the well. Injection into the test well lasted about 11 minutes at a constant flow rate of 9 l/min. During this period the level to water depth was constantly noted, and a minimal disturbance was observed in the range of few centimetres (< 2cm). EC and temperature measurements were taken and recorded at the formerly set up interval of 20 seconds, until the baseline conditions in terms of EC were reinstated. The whole test lasted about 2 hrs. Results Processing of experimental data to estimate the velocity of filtration was carried out starting from equation [1], which is the equation of a straight line with an angular coefficient: [3] m = αAvf V = kost ∙ vf Data were plotted in semi-logarithmic form, and a value for m for each depth sampled was obtained, from which the corresponding value of vf was derived. Parameter α may generically vary between 0 and 8 (Gaspar, 1987) and in case of wells installed within granular soils without prefilter, it can be given by Ogilvi’s formula (1958): [4] α = 4 1+( r1 r2 )2+ k k1 [1−( r1 r2 )2] in which r1 and r2 are the internal and external radii of the well, and k and k1 are the permeability values of the aquifer and of the filter respectively. Laboratory tests and many field investigations have in any case shown that when k1>>k, α tends to be around 2 (Gaspar, 1987). The overall results are shown in Figure 9, while Table 3 shows values of real velocity (vr) and hydraulic permeability (K), calculated by assuming α = 2 and ne = 30%. Table 3 – Filtration and flow velocities and hydraulic permeability Depth [m] from wellhead vf [m/d] vr [m/d] K [m/s] 8 1.85 6.15 6.11E-03 7 1.96 6.54 6.49E-03 6 2.73 9.11 9.04E-03 5 2.27 7.55 7.49E-03
  • 10. 10 Figure 9 – Dilution logs Results of the test are briefly summarized below.  In line with what observed during the drilling activities, the aquifer is characterized by a high hydraulic permeability (gravel and sand).  Although according to stratigraphic logs the aquifer looks homogeneous, results of the SPD test provide a better definition and allow for identifying zones with different velocities of filtration.  The trend of dilution profile at the depth of 6 m shows that this layer, positioned at the middle of the screened interval, has the highest velocity of filtration.  Overall the tracer is rapidly and uniformly evacuated. Conclusions and future improvements Seeking for an alternative solution to obtain hydrogeological characteristics and minimize the production of wastes and associated risks, an experimental methodology (the single point dilution method) was approached. In order to optimize and standardize the procedure for executing such test, a customized EC- temperature logging device has been designed and developed using open-source hardware and software. This solution allowed for reducing the costs of instruments supply, minimize the hours in the field of an experienced operator, and obtain accurate and reliable data that can be used to build groundwater remediation activities. The custom-built device can be easily adapted to different test conditions. Further improvements include  the implementation of a single cable for each sensor, allowing for positioning each probe at a desired depth and not limiting the recording interval to 1 m,  the addition of a GPRS module for complete remote connectivity,  the possibility to use different probes, such as ORP, pH and DO to measure other chemical-physical parameters. Nowadays, given the accessibility of low-cost environmental sensors and open-source technologies, building innovative and cost-effective devices on which rely to improve the design of remediation activities is just a matter of time.
  • 11. 11 References Halevy E., Moser H., Zellhofer O. & Zuber A. (1967) Borehole dilution techniques: A critical review. Proceedings of the Symposium on Isotopes in Hydrology, pp. 531-564 IAEA, Vienna, Austria. Hulla J, Ravinger R. & Turcek P. (1982) Radio-indicator tests in hydrogeological boreholes. Bulletin of Engineering Geology and the Environment Volume 26-27 n.1, 1982 pp. 439-442. Gaspar E. (1987) Modern trends in tracer hydrology. CRC Press, Florida. Ogilvi, N.A. (1958) Electrolytic method for the determination of the ground water filtration velocity. Bulletin of Science and Technology News, n. 4 (16), Moscow, Russia: Gosgeoltehizdat. Sottani A. & Dal Prà A. (1995) Misure di velocità di deflusso delle acque sotterranee con il metodo della diluizione puntuale in un sito campione dell’alta pianura veneta - Galliera V. Italia Settentrionale. 2° I.M.Y.R.A.G. International Meeting for Young Researchers in Applied Geology (11-13 October 1995), Peveragno (CN). Lamontagne S., Dighton J., and Ullman W. (2002) Estimation of groundwater velocity in riparian zones using point dilution tests CSIRO Land and Water Technical Report 14/02 Pitrak M., Mares S. and Kobr M. (2007) A Simple Borehole Dilution Technique in Measuring Horizontal Ground Water Flow Vol. 45, No. 1 – GROUND WATER – January-Ferbuary 2007 (pages 89-92). Ma R., McBratney A., Whelan B., Minasny B., Short M. (2010) Comparing temperature correction models for soil electrical conductivity measurement Springer Science+Business Media, LLC 2010. Stahl M.O., Ong J.B., Harvey C.F., Johnson C.D., Badruzzaman A.B.M., Tarek M.H., van Green A., Anderson J.A., and Lane J.W. (2013) Detecting well casing leaks in Bangladesh using a salt spiking method National Ground Water Association.