2. TESSOL SUMMARY
5/27/2013 (c) Thermal Energy Service Solutions Pvt. Ltd.
• Chilled water units with thermal backup
• Standard skid mounted packaged unit
Small comfort
cooling
• Customized solutions for HVAC
• Control system and integration
Commercial
HVAC
• Temperature range from -37oC to +81oC
• Chemical, Pharma, Dairy application
Industrial
Process Cooling
TESSOL provides Thermal Energy Storage Solutions for
commercial and Industrial process applications
3. SIMPLIFIED THERMAL STORAGE CONCEPT
5/27/2013
COMPRE
SSOR
CONDENSER
EVAPO
RATOR THERMAL STORAGE
LOAD
CHARGING IN OFF PEAK HOURS
DISCHARGING DURING PEAK TARIFF / LOADS
(c) Thermal Energy Service Solutions Pvt. Ltd.
THERMAL
STORAGE
LOAD COM
PRES
SOR
CONDENS
ER
THERMAL
STORAGE
LOAD
4. 5/27/2013 (c) Thermal Energy Service Solutions Pvt. Ltd.
WHY THERMAL STORAGE?
• Significant reduction in Chiller Size
• Reduced backup, cabling etc.
Capital Cost
Reduction
• Low Maximum Demand Charges
• Low energy bills and maintenance costs
Operating cost
reduction
• Reduced refrigerant use
• Higher efficiency of power plants
Environmental
Advantage
5. 5/27/2013
WHEN DOES THERMAL STORAGE MAKES SENSE?
• One has high power consuming partial day operation
like office building, process cooling, milk chilling etc.
• One uses DG backup power for more than 3 hours in a
day
• One is expanding / revamping his installation
• Intends to use waste heat / renewable energy sources
(c) Thermal Energy Service Solutions Pvt. Ltd.
7. WHY DO DISCOMS SUPPORT THIS?
5/27/2013
0
2000
4000
6000
8000
10000
12000
00 -
01
01 -
02
02 -
03
03 -
04
04 -
05
05 -
06
06 -
07
07 -
08
08 -
09
09 -
10
10 -
11
11 -
12
12 -
13
13 -
14
14 -
15
15 -
16
16 -
17
17 -
18
18 -
19
19 -
20
20 -
21
21 -
22
22 -
23
23 -
24
Rs./Mwhr
Time of Day
IEX Power Prices for Dec 2012
E1
N1
S1
W1
KARNATAKA IMPLEMENTS TOD TARIFF FOR HT CUSTOMERS
MAHARASHTRA IMPLEMENTS TOD TARIFF FOR HT CUSTOMERS
(c) Thermal Energy Service Solutions Pvt. Ltd.
HUGE COST DIFFERENTIAL BETWEEN THEIR PEAK AND OFFPEAK COSTS
8. TESSOL - LEADERSHIP
Rajat Gupta
• Ex COO Promethean Power, Division head at Bosch Rexroth
• Designed and developed the TES systems for Promethean milk
coolers, Automation systems for Bosch Rexroth group
• B.Tech Mech. IITD, MBA Harvard Business School, Worked in US, EU and
India
Rustom Irani
• Founder CEO at Icelings pvt. Limited, largest Ice machine manufacturers
in India , VP M&T Bank USA
• Pioneer in ice plants manufacturing and branded ice retailing in India
• BA University of Oklahoma, MBA Cornell Johnson School
(c) Thermal Energy Service Solutions Pvt. Ltd.5/27/2013
11. TESSOL - ENGINEERING TOOLS
5/27/2013 (c) Thermal Energy Service Solutions Pvt. Ltd.
CFD Simulations for performance
PCM Encapsulations
Analytical Design Tools
Profile Estimation Tool
12. PROTOTYPE R&D SETUP
5/27/2013 (c) Thermal Energy Service Solutions Pvt. Ltd.
32 CHANNEL DATA ACQUISITION SYSTEM
3.6 TRH SYSTEM WITH CONDENSING UNIT
& DISCHARGE FCU
13. SMALL COMFORT COOLING
5/27/2013 (c) Thermal Energy Service Solutions Pvt. Ltd.
Features
• 6TR unit with Integrated storage
• Up to 40% capacity augmentation
• 4 hours AC backup without power
• PLC based control system for
automatic switching over
• Skid mounted system
Benefit
• Suitable for places with 3 hours of DG
usage
• Perfect replacement of VRV systems
• Reduced operating costs
• Simple to maintain
• Optional Hot water generation
14. THERMAL ICE STORAGE 0oC PCM
5/27/2013 (c) Thermal Energy Service Solutions Pvt. Ltd.
Pressurized
Tank
Open Tank
15. CONDENSING TEMPERATURE
REDUCTION
5/27/2013 (c) Thermal Energy Service Solutions Pvt. Ltd.
Features
• 22oC PCM storage
• Uses lower wet bulb temp. /
chiller return temp
• Can be charged while normal
operation
• Energy usage ~ off peak
• Improves efficiency and
increases capacity during peak
times
• Condensing temperature ~ 30oC
Applications
• Meeting peak load
requirements
• Saving operating costs
• Using free cooling
CONCEPT CIRCUIT DESIGN FOR THE SYSTEM
16. NATURAL WET BULB BASED COOLING
5/27/2013
(c) Thermal Energy Service Solutions Pvt.
Ltd.
Features
• 22oC PCM storage
• Uses lower wet bulb
temp. at night
• Hybrid (50% capacity)
chiller for backup
• Energy usage ~ 250W
• Use 8oC, 11oC, 15oC PCMs
Applications
• Pre-cooling of fresh air
• Radiant cooling systems
17. MILK CHILLING CENTER - APPLICATION
5/27/2013 (c) Thermal Energy Service Solutions Pvt. Ltd.
Project Specs
• 0oC PCM storage (220 TRH)
• 8 hours of operation
• 30,000 liters of milk
• Eliminate DG usage
• Reduce chiller size
Applications
• Food processing
industry
• Chemical / Pharma
reactors
18. LOAD FORECASTING*
5/27/2013 (c) Thermal Energy Service Solutions Pvt. Ltd.
LOAD FORECAST
SYSTEM
CHARACTERISTICS
POWER
TARIFF
• SEB TARIFF
• DG USAGE
• RENEWABLE SOURCE
• TES TYPE
• PHYSICAL
CHARACTERISTICS
• STATISTICAL DATA
• LOAD FACTORS
• WEATHER DATA
OPTIMIZATION
PROGRAM
OPTIMAL DAILY
OPERATING STRATEGY
• Forecasts Day Ahead Load for the Building
• Minimizes Daily Operating Cost of HVAC
* This is currently under
development