IRJET- A Research on Comparing the Seismic Effect on Shear Wall Building and Without- Shear Wall Building – A Review
5. Jan 2019
•
0 gefällt mir
1 gefällt mir
×
Sei der Erste, dem dies gefällt
Mehr anzeigen
•
86 Aufrufe
Aufrufe
×
Aufrufe insgesamt
0
Auf Slideshare
0
Aus Einbettungen
0
Anzahl der Einbettungen
0
Jetzt herunterladen
Downloaden Sie, um offline zu lesen
Melden
Ingenieurwesen
https://irjet.net/archives/V5/i12/IRJET-V5I12234.pdf
IRJET Journal
Folgen
Fast Track Publications
Anzeige
Anzeige
Anzeige
Recomendados
IRJET- Effect of Infill Wall Stiffness Variations on the Behaviour of RC ...
IRJET Journal
29 Aufrufe
•
4 Folien
IRJET- Review Paper on Comparative Analysis of Flat Slabs & Conventional RC S...
IRJET Journal
50 Aufrufe
•
5 Folien
IRJET- Seismic Analysis of Buildings with Shear Wall having Horizontal Ir...
IRJET Journal
113 Aufrufe
•
6 Folien
IRJET- Analytical Design for Optimization of Shear Wall for Flat Slab
IRJET Journal
20 Aufrufe
•
4 Folien
IRJET-Comparing the Effect of Earthquake on Shear wall building and Non-Shear...
IRJET Journal
100 Aufrufe
•
4 Folien
IRJET- A Study on Effect of LRB Isolators on Varying Height of Rectangula...
IRJET Journal
24 Aufrufe
•
5 Folien
Más contenido relacionado
Presentaciones para ti
(20)
Seismic Evaluation of Multi-storeyed Buildings On Plain Ground And Curve Slop...
IJSRD
•
321 Aufrufe
Effect of vertical discontinuity of columns in r.c frames subjected to differ...
eSAT Journals
•
207 Aufrufe
Study on Influence of Positions of Core Wall for Structures with Step Back Co...
IRJET Journal
•
36 Aufrufe
IRJET-Analysis of G+25 RCC Bare Framed Structure with Shear Wall Under the Ef...
IRJET Journal
•
20 Aufrufe
EFFECT OF SHEAR WALL AREA ON SEISMIC BEHAVIOR OF MULTI STORIED BUILDINGS WITH...
Ijripublishers Ijri
•
1.5K Aufrufe
Seismic Analysis of G 10 Storey Building with Various Locations of Shear Wall...
ijtsrd
•
343 Aufrufe
Review paper on seismic responses of multistored rcc building with mass irreg...
eSAT Journals
•
1.1K Aufrufe
IRJET- A Review on Analysis of Soft Story at Intermediate Levels in a Multi-S...
IRJET Journal
•
29 Aufrufe
Review on seismic performance of multi storied rc building with soft storey
eSAT Journals
•
355 Aufrufe
IRJET- Seismic Analysis of Multi-Storey Building with and without Floating Co...
IRJET Journal
•
50 Aufrufe
Literature review on Seismic Pounding of Adjacent Buildings
IRJET Journal
•
118 Aufrufe
Review on Effective utilization of RCC Shear walls for Design of Soft Storey ...
IJERA Editor
•
38 Aufrufe
Seismic Analysis of Multistoreyed RC Building Due to Mass Irregularity by Tim...
IRJET Journal
•
148 Aufrufe
IRJET- Behavior and Comparison of Multistory Building of Shear Wall with and ...
IRJET Journal
•
10 Aufrufe
IRJET- Post Peak Response of Reinforced Concrete Frames with and without in F...
IRJET Journal
•
35 Aufrufe
IRJET- Review on Seismic Analyses of RC Frame Structure by using Bracing ...
IRJET Journal
•
11 Aufrufe
Performance of shear wall building during seismic excitations
IAEME Publication
•
747 Aufrufe
STUDY ON SEISMIC EFFECT OF HIGH RISE BUILDING SHEAR WALL/WALL WITHOUT SHEAR WALL
IAEME Publication
•
651 Aufrufe
IRJET- A Review Paper on Seismic Analysis of Old Masonry Buildings using Equi...
IRJET Journal
•
36 Aufrufe
IRJET- Effective Location of Shear Wall on Performance of Building Frame ...
IRJET Journal
•
7 Aufrufe
Similar a IRJET- A Research on Comparing the Seismic Effect on Shear Wall Building and Without- Shear Wall Building – A Review
(20)
Study on the effect of special shear walls on seismic behaviour of multi- sto...
IRJET Journal
•
3 Aufrufe
REVIEW PAPER ON SEISMIC RESPONSE OF FLAT SLAB & CONVENTIONAL SLAB WITH DIFFER...
IRJET Journal
•
8 Aufrufe
Comparative study of tall structures with softstorey openings and shearwall
ShreehariKulkarni7
•
7 Aufrufe
IIRJET-Comparison of Seismic Analysis of Multistoried Building with Shear Wal...
IRJET Journal
•
69 Aufrufe
Performance based seismic design of the multi-storied reinforced concrete bui...
IRJET Journal
•
2 Aufrufe
Seismic Response of Multi storey Flat Slab Building with and without Shear Wall
IRJET Journal
•
90 Aufrufe
Seismic Performance and Shear Wall Location Assessment of a RC Building- Eva...
IRJET Journal
•
80 Aufrufe
ANALYSIS AND DESIGN OPTIMIZATION OF SHEAR-WALL IN CASE OF HIGH-RISE BUILDING ...
IRJET Journal
•
1 Aufruf
IRJET- A Research on Comparing the Effect of Seismic Waves on Multistoried Bu...
IRJET Journal
•
24 Aufrufe
IRJET- A Review on R.C.C. Structure with Fully, Partially and without Infille...
IRJET Journal
•
5 Aufrufe
IRJET- Seismic Linear Analysis of Low Rise Open Ground Storey Buildings
IRJET Journal
•
47 Aufrufe
Analysis of High Rise Multistoried Building With and without Shear Wall By Re...
IRJET Journal
•
3 Aufrufe
IRJET- Analysis of Various Effects on Multistory Building (G+27) by Staad Pro...
IRJET Journal
•
44 Aufrufe
IRJET- Study of Behaviour of Multi-Storey Building with Shear Walls
IRJET Journal
•
64 Aufrufe
Significance of shear wall in flat slab multi storied building - A Review
IRJET Journal
•
88 Aufrufe
IRJET- Study of Literature on Seismic Response of RC Irregular Structure
IRJET Journal
•
32 Aufrufe
COMPARATIVE ANALYSIS OF MULTISTORY BUILDING WITH AND WITHOUT SHEAR WALL, X BR...
IRJET Journal
•
2 Aufrufe
IRJET- Effective Location of Shear Wall, its Significance and Displacement An...
IRJET Journal
•
29 Aufrufe
IRJET-Effect of Shear Wall on Seismic Performance of RC Open Ground Storey Fr...
IRJET Journal
•
7 Aufrufe
IRJET- Study on Shear Wall and Bracing in Irregular Structure and Regular Str...
IRJET Journal
•
46 Aufrufe
Anzeige
Más de IRJET Journal
(20)
AN INVESTIGATION ON THE EFFICACY OF MARBLE DUST POWDER FOR STRENGTHENING THE ...
IRJET Journal
•
28 Aufrufe
A Survey on Person Detection for Social Distancing and Safety Violation Alert...
IRJET Journal
•
9 Aufrufe
Thermal Analysis and Design Optimization of Solar Chimney using CFD
IRJET Journal
•
7 Aufrufe
Common Skin Disease Diagnosis and Prediction: A Review
IRJET Journal
•
42 Aufrufe
A STUDY ON TWITTER SENTIMENT ANALYSIS USING DEEP LEARNING
IRJET Journal
•
22 Aufrufe
Band structure of metallic single-walled carbon nanotubes
IRJET Journal
•
5 Aufrufe
IoT Based Assistive Glove for Visually Impaired People
IRJET Journal
•
10 Aufrufe
A SUPERVISED MACHINE LEARNING APPROACH USING K-NEAREST NEIGHBOR ALGORITHM TO ...
IRJET Journal
•
3 Aufrufe
An Overview of Traffic Accident Detection System using IoT
IRJET Journal
•
6 Aufrufe
Artificial Neural Network: A brief study
IRJET Journal
•
4 Aufrufe
Review Paper on Performance Analysis of LPG Refrigerator
IRJET Journal
•
6 Aufrufe
WOLBACHIA PIPIENTIS AND VARROA DESTRUCTOR MITE INFESTATION RATES OF NATIVE VE...
IRJET Journal
•
5 Aufrufe
Survey on Automatic Kidney Lesion Detection using Deep Learning
IRJET Journal
•
6 Aufrufe
A Review on Safety Management System in School Bus
IRJET Journal
•
10 Aufrufe
Design and Validation of a Light Vehicle Tubular Space Frame Chassis
IRJET Journal
•
7 Aufrufe
SMART BLIND STICK USING VOICE MODULE
IRJET Journal
•
12 Aufrufe
AUTOMATIC HYPODERMIC INFUSION REGULATOR
IRJET Journal
•
7 Aufrufe
Mobile Application of Pet Adoption System
IRJET Journal
•
11 Aufrufe
Literature Survey on “Crowdfunding Using Blockchain”
IRJET Journal
•
8 Aufrufe
Pricing Optimization using Machine Learning
IRJET Journal
•
12 Aufrufe
Último
(20)
Verilog_ppt.pdf
ApurbaDebnath8
•
0 Aufrufe
Filp Flops counter registers.pdf
MuditK4
•
0 Aufrufe
mapreduceApril24.ppt
Anonymous9etQKwW
•
0 Aufrufe
TIME FRAME OVERHAUL 3608 PT. SAIPEM.pdf
danialkurnia
•
0 Aufrufe
Structural Theory I (Part 1/2)
National Chung Hsing University
•
0 Aufrufe
4. APL PI Presentation 2023.pdf
PROFIBUS and PROFINET InternationaI - PI UK
•
0 Aufrufe
final project presentation.pptx
Poornimak52
•
0 Aufrufe
6. SRCI Profibus International v2.pdf
PROFIBUS and PROFINET InternationaI - PI UK
•
0 Aufrufe
cmcsseminarnand-160523111422.pdf
whmonkey
•
0 Aufrufe
RoboticsAndMechatronics_IndustrialRobotics_part5_2021.pptx
pradyumna42
•
0 Aufrufe
Basics of Hydraulic Systems.ppt
Rupesh48694
•
0 Aufrufe
G. Kim, CVPR 2023, MLILAB, KAISTAI
MLILAB
•
0 Aufrufe
Control Strategies for Autonomous quadrotors.pptx
MahiRanka2
•
0 Aufrufe
10. PI_Dunton - OT Security.pdf
PROFIBUS and PROFINET InternationaI - PI UK
•
0 Aufrufe
compositematerials-140309122625-phpapp02.pdf
whmonkey
•
0 Aufrufe
International Journal of Computational Science, Information Technology and Co...
rinzindorjej
•
0 Aufrufe
ppt for review.ppt
SaranyaRamaswamy2
•
0 Aufrufe
UNIT-II-IWM.pptx
KawinKit
•
0 Aufrufe
CSULB degree.pdf
lunabarajas816
•
0 Aufrufe
International Journal of Computational Science, Information Technology and Co...
rinzindorjej
•
0 Aufrufe
Anzeige
IRJET- A Research on Comparing the Seismic Effect on Shear Wall Building and Without- Shear Wall Building – A Review
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 05 Issue: 12 | Dec 2018 www.irjet.net p-ISSN: 2395-0072 © 2018, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 1247 A Research on Comparing the Seismic Effect on Shear wall building and Without- Shear Wall Building – A Review Mr. Ankur vaidya1, Mr. Shahayajali Sayyed2 1M.tech student, Dept. of Civil Engineering & G.H.Raisoni University, Saikheda, chhindwara (MP), India 2Asst. Professor, Dept. of Civil Engineering & G.H.Raisoni University, Saikheda, chhindwara (MP), India ----------------------------------------------------------------------***--------------------------------------------------------------------- Abstract – Earthquakes are most volatile and distressing of all natural disasters. Amongst all methods applied for earthquake resistantmultistoriedstructuresshear walls are the most adopted. Shearwall is a structural component located at different places in a building from foundation level to top parapet level, used to defend against lateral forces i.e parallel to the plane of the wall. Shear walls are structural members which are used to avert lateral forces due to earthquake and wind. In this paper review of different researchers on the concept of multistoried building with and without shear wall is paraphrased. In India, most adopted type of earthquake resistant structures is with shear wall. These structural walls may differ based on their design and utility and their position in any building plays an important role for resisting lateral force. Key Words: Shear Wall, Non- Shear wall Building, Earthquake, Lateral Forces etc. 1. INTRODUCTION Earthquake in general had a long history of deadly devastations in the past. Basically the response of the structure due to ground motion is an essential factor to analyze and design any earthquake resistant structure. The loads or forces which a structure subjected to earthquake motions are called upon to resist, the distortions induced by the motion of the ground on which it rests. Earthquakes can be measured in terms of energy release i.e. measuring amplitude, frequency, and location of seismic waves and also by evaluating intensity i.e. considering the destructive effect of shaking ground on people, structures and natural features. The properties of a building are lateral stiffness, lateral strength and ductility. Lateral stiffness refers to the initial stiffness of the building, even though stiffness of the building reduces with increasing damage. Lateral strength refers to the maximum resistance that the building offers during its entire history of resistance to relative deformation. Ductility towards lateral deformation refers the ratio of the maximum deformation and the idealized yield deformation. The effect of the vertical component of ground motion is generally considered not to besignificant and is neglected except in cantilevers. 1.1 Shearwall and its properties:- Shearwall is a structural member positioned at different places in a building from foundation level to top parapet level, used to resist lateral forces i.e parallel to the plane of the wall. There are different materials by which shear wall can be constructed but reinforced concrete (RC) buildings often have vertical plate-like Reinforced concrete walls (Figure 1) in addition to slabs, beams and columns. Their thickness can be as low as 150mm, or as high as 400mm in high rise buildings. Shear walls are usually provided along both length and width of buildings. Figure 1:- Shear wall in building These walls are more important in seismically active zones because during earthquakes shear forces on the structure increases. Shear walls should have more strength and stiffness. Shear walls provide adequate strength and stiffness to control lateral displacements. Shear walls perform dual action that is they as lateral as well as gravity load- bearing elements. Concrete Shear wall buildings are usually regular in plan and in elevation.
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 05 Issue: 12 | Dec 2018 www.irjet.net p-ISSN: 2395-0072 © 2018, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 64 1.2 Advantages of Shear Walls in RC Buildings: Shear wall resist horizontal lateral force and provide earthquake resistance It possess very large in-plane stiffness which resist lateral load Shear walls are helpful in controllingdeflection. RCC shear walls are easy to construct – reinforcement detailing It minimizes earthquake damage to structural damage and non-structural damages. Well-designed shear walls not only provide adequate safety but also provide great measure of protection against costly non- structural damage during moderate seismic damages. 2. LITERATURE REVIEW Concrete shear walls are most common and useful type of shear wall for any multistoried building. Many researchers and scholars had researched on the shear wall configuration in any building and types of shear wall. The ability of shear wall to resist lateral forces generated by earthquake and wind force is studied. An effort had been made to study these literatures andconcludeoverthistopic. Dr.B.Kameshwari et.al1 analysed the influence of drift and inter storey drift of the structure on various configuration of shear wall panels on high rise structures. The bare frame was compared with various configurations like i) Conventional shear wall ii) Alternate arrangement of shear wall iii) Diagonal arrangement of shear wall iv) Zig Zag arrangement of shear wall v) Influence of lift core shear wall. From the study it was found that Zig Zag shear wall enhanced the strength and stiffness of structure compared to other types. In earthquake prone areas diagonal shear wall was found to be effective for structure. B. R. Reddy et.al2 used Stadd Pro software for analysis and design of earthquake resistant structures using Shearwall. According to their research work, constructions made of shear walls not only provide lateral strength but also increase the strength parameters and effectiveness to bare horizontal loads. Shear walls have a peculiar behavior towards various types of loads. Research work was adopted to the college building of VITS block, Deshmukhi Hyderabad city using shear wall. The building behavior was checked for rigidity factor, reactions, shear center, shear force and bending moment. The solution for shear wall location in multi-storey building based on its both elastic and elas- to-plastic behaviors were also considered. The earthquake load were calculated and applied for the same building of 3 bays and 3 floors. Model results are calculated and analyzed for the effective location of shear wall. After comparing the result it was found that the provision of shear wall in this building will make the structure completely earth quake resistant in zone II of Hyderabad. Further it is also found that the results of manual and STAAD Pro are almost same, the STAAD Pro results saves considerable amount of reinforcement. P. Chandurkar et.al.3 investigated about a building with Shearwall and without Shearwall were considered and compared. As per their research work Structural walls provide an efficient bracing system and offer great potential for lateral load resistance. The properties of these seismic shear walls dominate the response of the buildings, and therefore, it is important to evaluate the seismic response of the walls appropriately. According to their study, main focus was to determine the solution for shear wall location in multi-storey building. Effectiveness of shear wall had been studied with the help of four different models. One model was bare frame structural system and other three models were dual type structural system. When earthquake load were applied to the building of ten stories located in zone II, zone III, zone IV and zone V, parameters like Lateral displacement, story drift and total cost required for ground floor were calculated in both the cases replacing column with shear wall. E- Tabs software was adopted for analysis. From the analysis, it is observed that in 10 story building, constructing building with shear wall in short span at corner (model 4) is economical as compared with other models. Thus large dimension of shear wall is not effective in 10 stories or below 10 stories buildings. It was observed that the shear wall is economical and effective in high rise building. From the research work it was observed that changing the position of shear wall will affect the attraction of forces, so that wall must be in proper position. Also if the dimensions of shear wall are large then major amount of horizontal forces are taken by shear wall. Providing shear walls at adequate locations substantially reduces the displacements due to earthquake. M. D. Kevadkar and P. B. Kodag4 have done lateral load analysis of R.C.C. Building (G+12) by considering 3 models. Out of this 1st model is without bracing and shear wall, 2nd model with different shear wall system and 3rd Model with Different bracing system the computer aided analysis is done by using E-TABS to find out the effective lateral load system during earthquake in high seismic areas. The performance of the building is evaluated in terms of Lateral Displacement, Storey Shear and Storey Drifts, Base shear and Demand Capacity (Performance point). Anshuman.S et al.5 determined the solution for shear wall location in multistory building based on its both elastic and elastoplastic behaviors. An earthquake load is calculated and applied to a building of fifteen stories located in zone IV. Elastic and elastoplastic analyses were performed using both STAAD Pro 2004 and SAP (2000) software packages. Shear forces, bending moment and story drift were computed in both cases and location of shear wall was established based upon the results.
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 05 Issue: 12 | Dec 2018 www.irjet.net p-ISSN: 2395-0072 © 2018, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 65 Romy Mohan et al.6 presented Dynamic Analysis of RCC buildings with Shear Wall. for analysis consider the two multi storey buildings, one of six and other of eleven storeys have been modeled using software package SAP 2000 for earthquake zone V in India. Six different types of shear walls with its variation in shape are considered for studying their effectiveness in resisting lateral forces. This paper also deals with the effect of the variation of the building height on the structural response of the shear wall. Manoj S. Mendhekar et.al.7 stated the economic means by which lateral load resistance can be achieved in a multistoried building. In their study, seismic behavior, modes of failure, and factors influencing the structural response of buildings were discussed. Many expressions were developed to estimate the flexural strength of slender rectangular shear wall sections with uniformly distributed vertical reinforcement. In this study various aspects of analysis and design of a shear wall are discussed, also different types of shear wall are discussed with their failure modes. Algebraic expressions for calculating flexural strength of shear wall sections were developed and load-moment interaction diagram were generated using this expressions. The results obtained by both the methods were quite favorable. Also details of coupled shear wall were stated and the difference between solid shear wall and coupled shear wall (shear wall with opening) was studied. Also the relations to calculate the forces in shear wall for its design were shown. From their study it was clear that flanged shear wall sections were further extended for analysis and design and are most suitable. Syed.M.Katami et.al8 presented the results of time history analysis which addressed the effect of openings in shear walls near- fault ground motions. A model of ten storey building with three different types of lateral load resisting system: Complete shear walls, shear walls with square opening in the centre and shear wall with opening at right end side were considered. From the results it was observed that shear walls with openings experienced a decrease in terms of strength. The maximum lateral displacement of complete shear wall is 17% less than that of shear walls with openings at centre whose displacement is found to be 8% less than that of shear walls with openings at right end. Venkata Sairam Kumar.N et.al.9 reviewed various papers on shear walls and stated that shear walls are structural systems which provide stability to structures from lateral loads like wind, seismic loads. These structural systems are constructed by reinforced concrete, plywood/timber unreinforced masonry, reinforced masonry at which these systems are sub divided into coupled shear walls, shear wall frames, shear panels and staggered walls. The paper was made in the interest of studying various research works involved in enhancement of shear walls and their behaviour towards lateral loads. As shear walls resists major portions of lateral loads in the lower portion of the buildings and the frame supports the lateral loads in the upper portions of building which is suited for soft storey high rise building. Building which are similar in nature constructed in India, as in India base floors are used for parking and garages or officers and upper floors are used for residential purposes. They have concluded with a broad note that researches was carried mainly on application of cyclic load tests and behaviour of different types of shear walls in cyclic application of loads. Researchers studied various parameters like enhancement of stiffness, drift, development forces in buildings and also to observe perfect location of shear wall location in building frame for construction. It was seen that any type of building which is tall and can be affected with lateral forces like earthquake and wind forces can be constructed with shear walls. Shear walls can be used as lateral load resisting systems and also retrofitting of structures. Internal shear walls are more efficient than external shear walls when compared with cyclic load tests by researchers. Varsha.R.Harne10 considered a six storey RCC building which is subjected to Earthquake loading in zone II to determine the strength of RC wall by changing the location of shear wall using STAAD.Pro. Seismic coefficient method is used to calculate the earthquake load as per IS 1893 – 2002 (Part I). Four different models like structure without shear wall, structure with L type shear wall, structure with shear wall along periphery, structure with cross type shear wall were modeled for analysis. Compared to other models the shear force and bending moment, for structure with shear wall along the periphery is found to be maximum at the ground level and roof level respectively. Hence the shear wall provided along the periphery of the structure is found to be more efficient than all other types of shear wall. Bhruguli H. Gandhi11 researched for the behavior of shear wall with opening under seismic load action. In this research, it is stated that shear walls are generally located at the sides of buildings or arranged in the form of core that houses stairs and lifts. Due to functional requirements such as doors, windows, and other openings, a shear wall in a building contains many openings. In most of the apartment building, size and location of openings in shear wall are made without considering its effect on structural behavior of the building. In this research, study is carried out on 6- story frame-shear wall buildings, using linear elastic analysis with the help of finite element software, StaddPro under earthquake loads in equivalent static analysis. Six different types of models were created and analysed, starting from first, Concentric opening 20%, concentric opening 40%, concentric opening 50%, concentric opening 60%, Eccentric opening 20%, Zigzag opening 20%. The results reveal that stiffness as well as seismic responses of structures is affected by the size of the openings as well as their locations in shear wall. It is also explored that top lateral drift of the system can also be reduced thickening the element in the model around the opening of shear wall. From the research percent of
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 05 Issue: 12 | Dec 2018 www.irjet.net p-ISSN: 2395-0072 © 2018, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 66 opening increases deflection increases up to 40% in proportion but after that as percentage of opening increases deflection increases more rapidly. For 20% opening Eccentric zigzag has lesser deflection and Eccentric Straight has maximum deflection and concentric loading has less deflection than Eccentric Straight. Also opening increases bottom stresses also increases proportionally up to 40% then after Stresses increases vastly. S.M. khatami et.al.12 investigateted the effect of flange thickness on nonlinear behavior of flanged shear walls. Four T-shape flanged shear walls were studied and analyzed using finite element method. The total volume of each model is similar, such that when thickness decreases in the model, the length of wing increases. The results indicated that in the presence of lateral loads, the thickness has a significant effect on the shear absorption, ductility, displacement and crack pattern of the flanged shear walls. Numerical results show that shear walls with thick flanges behave more efficient than walls with thin flanges. It was found that, lateral strength resisted by shear walls with thin flanges is 1250 kN which is 14 percent decrease compared with thick flanged wall. Moreover, nonlinear behavior of flanged shear wall with thick flanges shows that strength and ductility are equivalent. Finally, the analyses indicated that while flange is in pressure, the global behavior is much more improved compared with condition which is in tension. The comparison of models indicated that finite element model used in this study is capable of predicting the nonlinear behavior of the models when these are different thickness. Results of analysis in four models and load- displacement of them indicated that model named -2500TSW had better behavior. It had resisted about 1248 kN. This load is 14% higher than other models. Also, ductility of this model showed a good agreement. Ductility in the model-2500TSW model is 4.58 which is 3% higher than model-3100TSW. Results of analysis showed that model-3100TSW had better strength after yield, which was 18% higher than model- 2500TSW. Crack pattern in all of models showed that increase of thickness could decrease crack in shear wall. 3. CONCLUSIONS From the above study it can be concluded that, different researchers had studied different type of problems related to earthquake and addressed that shear wall are more prominent to resist lateral force due to earthquakes. Analysis by software’s such as StaddPro, Etabs etc. are also combined along with manual studies. Models are generated and shear walls are located at different positions in building to find the least displacement of the structure due to shear walls. Openings in shear wall are also an issue of concern of study of shear wall buildings. Generally openings provided in shear walls increase displacement in building. Moreover some researches statedthatchange in positions of shear wall effect the attraction of forces. Location of shear wall in any building substantially reduces displacements and reduces impact on the structure. Thus building without shear wall is a subject of concern and need to be retrofitted in places of high earthquake and wind impact. Future scope of studying this type of research work is an essential part of this review paper. Study of effect of shear wall building and without-shear wall building can be studied further by introducing a flange to column. Comparison can be made with a building without shear wall, with shear wall and with column flanges type structure. Moreover placement of shear walls at different locations is an essential aspect to be thought of for furtherstudy. ACKNOWLEDGEMENT I extend my sincerest gratitude to my parents, my friends, my Guides and my well wishers who had constantly encouraged me and helped me in all situations whenever needed during this project completion. A special Thanks to PROJECTium Nagpur for their support. REFERENCES 1) Dr. B. Kameshwari, Dr. G. Elangovan, P. Sivabala, G.Vaisakh, Dynamic Response Of High Rise Structures Under the Influence Of Discrete Staggered Shear Walls, International Journal of Engineering Science and Technology (IJEST), ISSN : 0975-5462 Vol. 3 No.10 October 2011 2) B. Ramamohana Reddy, M. Visweswara Rao, “Earthquake resistant design of a building using shear wall”. IJMETR, Volume no: 2 (2015), Issue no: 10, October 2015, ISSN no: 2348-4845. 3) P. P. Chandurkar, Dr. P. S. Pajgade, “Seismic analysis of RCC Building with and without shear wall”. IJMER, Vol.3, Issue 3, May-june 2013,pp- 1805-1810,2013. 4) M. D. Kevadkar and P. B. Kodag, “Lateral Load Analysis of R. C. C. Building”, IJMER International Journal of Modern EngineeringResearch,Vol.3,Issue.3,May-June 2013. 5) Anshuman. S, Dipendu Bhunia and Bhavin Ramjiyani, “Solution of Shear Wall Location in Multi Storey Building”, International Journal of Civil and Structural Engineering,Vol.2,September 2011. 6) Romy Mohan and C Prabha, “Dynamic Analysis of RCC Buildings with shear wall”, International Journal of Earth Science and Engineering,Vol.04, No.06, October 2011. 7) Manoj S. Medhekar, Sudhir K. Jain, “Seismic
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 05 Issue: 12 | Dec 2018 www.irjet.net p-ISSN: 2395-0072 © 2018, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 67 behaviour design and detailing of RC shear wall, Part 1: Behaviour and Strength”. The Indian Concrete Journal, July 1993. 8) Seyed M. Khatami, Alireza Mortezaei, Rui C. Barros, Comparing Effects of Openings in Concrete Shear Walls under Near-Fault Ground Motions, The 15thWorld Conference on Earthquake Engineering (2012) 9) Venkata Sairam Kumar.N, Surendra Babu.R, Usha Kranti.J, “Shear Wall- A Review”. IJIRSET, Vol. 3, Issue 2, February 2014, ISSN: 2319-8753. 10) Varsha R. Harne, Comparative Study of Strength of RC Shear Wall at Different Location on Multi- storied Residential Building, International Journal of Civil Engineering Research.ISSN 2278-3652 Volume 5, Number 4 (2014), pp. 391400. 11) Bhruguli H. Gandhi, “Effect of opening on behaviour of shear wall”. IJTRE, Volume 3, Issue 4, December-2015, ISSN: 2347 – 4718. 12) S. M. Khatami, A. Kheyroddin “The Effect of Flange Thickness on the Behavior of Flanged- Section Shear Walls”. ELSEVIER, Procedia Engineering 14 (2011) 2994–3000. 13) C.V.R.Murty , “Earthquake Tip: 23- Why are Buildings with Shear Walls preferred in Seismic Regions”. IITK-BMTPC Earthquake Tips. 14) C. V. R. Murty, Rupen Goswami, A. R. Vijayanarayanan, Vipul V. Mehta, “Earthquake Behaviour of Buildings”. GSDMA, Govetnment of Gujarat, September 2012. 15) S.K. Duggal, “Earthquake Resistant Design of Structures”, Second Edition, 2013, Oxford University Press, ISBN- 0-19-808352-1 16) IS 13920, (1993), “Indian Standard Code of Practice for Ductile Detailing of Reinforced Concrete Structures Subjected to Seismic Forces,” Bureau of Indian Standards, New Delhi. 17) IS 875 (Part 2):1987, Code of Practice for design loads for buildings and structures, Second revision. Bureau of Indian Standards, New Delhi. 18) IS 1893:2002 (Part 1), Criteria for earthquake resistant design of structures, Fifth revision. Bureau of Indian Standards, New Delhi. 19) IS 456:2000, Plain and reinforced concrete code of practice, Fourth revision, Bureau of Indian Standards, New Delhi.
Anzeige