A1 Analytical techniques
A2 Principles of spectroscopy
The Electromagnetic Spectrum:
Absorption spectra have parts ‘missing’.  In the diagram below the troughs indicate energy absorbed by the molecules
Observing with a hand held spectroscope gives you evidence for line  emission  spectra similar to the one shown below Here light is being emitted as the excited electrons drop down to lower ‘allowed’ energy levels.
•  a beam of infra red radiation is passed through the sample •  a similar beam is passed through the reference cell •  the frequency of radiation is varied •  bonds vibrating with a similar frequency absorb the radiation •  the amount of radiation absorbed by the sample is compared with the reference •  the results are collected, stored and plotted  The Infra-red Spectrophotometer
SYMMETRIC STRETCHING BENDING AND STRETCHING IN WATER MOLECULES
ASYMMETRIC STRETCHING BENDING AND STRETCHING IN WATER MOLECULES
BENDING AND STRETCHING IN WATER MOLECULES BENDING
Vertical axis Absorbance  the stronger the absorbance the larger the peak Horizontal axis Frequency wavenumber (waves per centimetre) / cm -1 Wavelength microns (m); 1 micron = 1000 nanometres INFRA RED SPECTRA -  INTERPRETATION
FINGERPRINT REGION •  organic molecules have a lot of C-C and C-H bonds within their structure •  spectra obtained will have peaks in the 1400 cm -1  to 800 cm -1  range •  this is referred to as the  “fingerprint”  region •  the pattern obtained is characteristic of a particular compound the frequency  of any absorption is also affected by adjoining atoms or groups.
IR SPECTRUM OF A CARBONYL COMPOUND •  carbonyl compounds show a sharp, strong absorption between 1700 and 1760 cm -1 •  this is due to the presence of the C=O bond
IR SPECTRUM OF AN ALCOHOL •  alcohols show a broad absorption between 3200 and 3600 cm -1 •  this is due to the presence of the O-H bond
WHAT IS IT! O-H STRETCH C=O STRETCH ALCOHOL ALDEHYDE CARBOXYLIC ACID One can tell the difference between alcohols, aldehydes and carboxylic acids by comparison of their spectra. O-H STRETCH C=O STRETCH AND
A4 Mass spectrometry
An outline of what happens in a mass spectrometer
Peaks appear due to characteristic fragments (e.g. 29 due to C 2 H 5 + ) and differences between two peaks also indicates the loss of certain units (e.g. 18 for H 2 O, 28 for CO and 44 for CO 2 ). Many of the fragments do not show up themselves on the spectrum because they are not ions.
FRAGMENTATION PATTERNS OF FUNCTIONAL GROUPS ,[object Object],[object Object],[object Object],[object Object]
2,6-dimethyloctane
A5 Nuclear magnetic resonance (NMR) spectroscopy
INTERPRETATION OF SPECTRA ,[object Object],[object Object],[object Object],[object Object],[object Object]
LOW RESOLUTION - HIGH RESOLUTION LOW RESOLUTION SPECTRUM OF 1-BROMOPROPANE ,[object Object],[object Object],[object Object]
How do you identify the different H environments in a molecule?  ,[object Object],[object Object],[object Object],[object Object],[object Object]
[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],INTEGRATION NOTICE THAT THE O-H SIGNAL IS ONLY A SINGLET
INTEGRATION ,[object Object],[object Object],[object Object],[object Object],IMPORTANT: It doesn’t provide the actual number of H’s in each environment, just the ratio Measure the distance between the top and bottom lines. Compare the heights from each signal and make them into a simple ratio.
MRI ,[object Object]
How NMR is used in body scanners
A6 Atomic absorption (AA) spectroscopy
This is what an Atomic Absorption spectroscopic machine looks like
This is the basic set up for AAS
Schematically
Schematically
UV-vis Spectroscopy and Beer’s Law ,[object Object],[object Object],[object Object]
A =  ε  bc In this equation, the absorbance (A) of the solution is directly proportional to the concentration (c) in moles/Liter, the pathlength (b) in cm-1 and the molar absorptivity (e ) in Lcm-1mol-1. Under the conditions of this experiment, the molar absorptivity and the path length are constant. Thus the absorbance of a solution is directly proportional to the concentration of solution. This concentration is expressed in molarity or moles/Liter.
This equation and relationship between absorbance and concentration can be used to of several samples of a particular chemical on the x-axis and the corresponding maximum absorbance on the y-axis, a Beer’s Law Plot is obtained. 
The Plot can then be used to determine an unknown concentration of the same chemical. At dilute concentrations, many chemical solutions obey Beer’s Law, resulting in a straight line plot with the general equation for a straight line  y = mx + b .
To find the unknown concentration of a solution, use the equation for a straight line and solve for x.  y = mx + b   Sample calculation: Using the Beer's Law Plot above, determine the unknown concentration of a solution with an absorbance reading of .600. In this example, the slope (m) is 6.414 and the intercept ( b) is -7.99 x 10 -3. Solving for x,  .600 = 6.414 x - 0.00799  x = 0.095 M
A7 Chromatography
What is Chromatography ? Chromatography is a technique for separating mixtures into their components in order to analyze, identify, purify, and/or quantify the mixture or components. Separate ,[object Object],[object Object],[object Object],[object Object],Components Mixture
Uses for Chromatography ,[object Object],[object Object],[object Object],[object Object],[object Object]
Definition of Chromatography ,[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object]
Uses for Chromatography ,[object Object],[object Object],[object Object],[object Object],[object Object],[object Object]
Definition of Chromatography ,[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object]
Types of Chromatography ,[object Object],[object Object],[object Object],[object Object],Types of Chromatography
Principles of Paper Chromatography ,[object Object],[object Object],[object Object]
Developing the Chromatograms
Observing the Chromatograms Concentration of Isopropanol 0% 20% 50% 70% 100%
Kinds of Chromatography 1. Paper Chromatography   2. Column Chromatography   3. Thin-layer Chromatography
LIQUID COLUMN CHROMATOGRAPHY  A sample mixture is passed through a column packed with solid particles which may or may not be coated with another liquid.  With the proper solvents, packing conditions, some components in the sample will travel the column more slowly than others resulting in the desired separation.
Column Chromatography
[object Object],[object Object]
A8HL Visible and ultraviolet (UV-Vis) spectroscopy
COLOURED IONS Theory   ions with a  d 10  (full) or  d 0  (empty) configuration are colourless   ions with partially filled d-orbitals tend to be coloured   it is caused by the ease of transition of electrons between energy levels   energy is absorbed when an electron is promoted to a higher level   the frequency of light is proportional to the energy difference   ions with  d 10  (full) Cu + ,Ag +  Zn 2+   or  d 0  (empty) Sc 3+  configuration are colourless e.g.  titanium(IV) oxide TiO 2  is white colour depends on ... transition element oxidation state ligand coordination number A characteristic of transition metals is their ability to form coloured compounds
SPLITTING OF 3d ORBITALS Placing ligands around a central ion causes the energies of the d orbitals to change Some of the d orbitals gain energy and some lose energy In an octahedral complex, two ( z 2  and x 2 -y 2 ) go higher and three go lower In a tetrahedral complex, three ( xy, xz  and yz ) go higher and two go lower  Degree of splitting depends on the CENTRAL ION   and the LIGAND The  energy difference between the levels affects how much energy is absorbed when an electron is promoted.  The amount of energy governs the colour of light absorbed. 3d 3d OCTAHEDRAL TETRAHEDRAL
COLOURED IONS Absorbed colour nm Observed colour nm VIOLET 400 GREEN-YELLOW 560 BLUE 450 YELLOW 600 BLUE-GREEN 490 RED 620 YELLOW-GREEN 570 VIOLET 410 YELLOW 580 DARK BLUE 430 ORANGE 600 BLUE 450 RED 650 GREEN 520 The observed colour of a solution depends on the wavelengths absorbed Copper sulphate solution appears blue because the energy absorbed corresponds to red and yellow wavelengths.  Wavelengths corresponding to blue light aren’t absorbed. WHITE LIGHT GOES IN SOLUTION APPEARS BLUE ENERGY CORRESPONDING TO THESE COLOURS IS ABSORBED
COLOURED IONS a solution of copper(II)sulphate is blue because red and yellow wavelengths are absorbed white light blue and green not absorbed
COLOURED IONS a solution of copper(II)sulphate is blue because red and yellow wavelengths are absorbed
Ultraviolet (UV) Spectroscopy – Use and Analysis Of all the forms of radiation that go to make up the electromagnetic spectrum UV is probably the most familiar to the general public (after the radiation associated with visible light which is, for the most part, taken for granted). UV radiation is widely known as something to be aware of in hot weather in having a satisfactory effect of tanning the skin but which also has the capacity to damage skin cells to the extent that skin cancer is a direct consequence of overexposure to UV radiation.  This damage is associated with the high energy of UV radiation which is directly related to its high frequency and its low wavelength (see the equations below). This is designed to introduce you to UV spectroscopy and give you enough information to ensure that you understand how you can use the technique as a quantitative as appose to a qualitative method.. c =   E = h  E = (hc)/   E    1/   E = energy; c = speed of light;    = wavelength;     = frequency;  h = Planck’s constant
Ultraviolet (UV) Spectroscopy – Use and Analysis When continuous wave radiation is passed through a prism a diffraction pattern is produced (called a spectrum) made up of all the wavelengths associated with the incident radiation. When continuous wave radiation passes through a transparent material (solid or liquid) some of the radiation might be absorbed by that material. This slide is part automatically animated – if animation does not occur click left hand mouse button. Radiation source Diffraction prism Spectrum Transparent material that absorbs some radiation Spectrum with ‘gaps’ in it If, having passed through the material, the beam is diffracted by passing through a prism it will produce a light spectrum that has gaps in it (caused by the absorption of radiation by the transparent material through which is passed). The effect of absorption of radiation on the transparent material is to change is from a low energy state (called the ground state) to a higher energy state (called the excited state).  The difference between all the spectroscopic techniques is that they use  different wavelength radiation that has different associated energy which can cause different modes of excitation in a molecule. For instance, with infra red spectroscopy the low energy radiation simply causes bonds to bend and stretch when a molecule absorbs the radiation.  With high energy UV radiation the absorption of energy causes transition of bonding electrons from a low energy orbital to a higher energy orbital. The energy of the ‘missing’ parts of the spectrum corresponds exactly to the energy difference between the orbitals involved in the transition.
Ultraviolet (UV) Spectroscopy – Use and Analysis    *  * n Occupied Energy Levels Unoccupied Energy Levels The bonding orbitals with which you are familiar are the   -bonding orbitals typified by simple alkanes.  These are low energy (that is, stable). Next (in terms of increasing energy) are the   -bonding orbitals present in all functional groups that contain double and triple bonds ( e.g.  carbonyl groups and alkenes). Higher energy still are the non-bonding orbitals present on atoms that have lone pair(s) of electrons (oxygen, nitrogen, sulfur and halogen containing compounds). All of the above 3 kinds of orbitals may be occupied in the ground state. Two other sort of orbitals, called antibonding orbitals, can only be occupied by an electron in an excited state (having absorbed UV for instance).  These are the   * and   * orbitals (the * denotes antibonding).  Although you are not too familiar with the concept of an antibonding orbital just remember the following – whilst electron density in a bonding orbital is a stabilising influence it is a destabilising influence (bond weakening) in an antibonding orbital. Antibonding orbitals are unoccupied in the ground state UV A transition of an electron from occupied to an unoccupied energy level can be caused by UV radiation.  Not all transitions are allowed but the definition of which are and which are not are beyond the scope of this tutorial.  For the time being be aware that commonly seen transitions are    to   * which correctly implies that UV is useful with compounds containing double bonds. A schematic of the transition of an electron from    to   *  is shown on the left. Increasing energy
Ultraviolet (UV) Spectroscopy – The Output The output from a UV scanning spectrometer is not the most informative looking piece of data!!  It looks like a series of broad humps of varying height.  An example is shown below. Decreasing wavelength in nm Increasing absorbance * *Absorbance  has no units – it is actually the logarithm of the ratio of light intensity incident on the sample divided by the light intensity leaving the sample. There are two particular strengths of UV (i) it is very sensitive  (ii) it is very useful in determining the quantity of a known compound in a solution of unknown concentration.  It is not so useful in determining structure although it has been used in this way in the past. The concentration of a sample is related to the absorbance according to the Beer Lambert Law which is described above.  A =  absorbance ; c =  concentration  in moles l -1 ;  l =  pathlength  in cm ;    =  molar absorptivity  (also known as  extinction coefficient ) which has units of moles -1   L cm  -1 . Beer Lambert Law A =   .c.l
Ultraviolet (UV) Spectroscopy – Analysing the Output Handling samples of known concentration If you know the structure of your  compound X  and you wish to acquire UV data you would do the following. Prepare a known concentration solution of your sample. Run a UV spectrum (typically from 500 down to 220 nm). From the spectrum read off the wavelength values for each of the maxima of the spectra (see left) Read off the absorbance values of each of the maxima (see left). Then using the known concentration (in moles L -1  ) and the known pathlength (1 cm) calculate the molar absorptivity (  ) for each of the maxima. Finally quote the data as follows (for instance for the largest peak in the spectrum to the left and assuming a concentration of 0.0001 moles L -1  ).  max = 487nm  A= 0.75     =  0.75 /(0.001 x 1.0) = 7500 moles -1  L  cm  -1   Determining concentration of samples with known molar absorptivity (  ). Having used the calculation in the yellow box to work out the molar absorptivity of a compound you can now use UV to determine the concentration of compound X in other samples (provided that these sample only contain pure X). Simply run the UV of the unknown and take the absorbance reading at the maxima for which you have a known value of   .  In the case above this is at the peak with the highest wavelength (see above).  Having found the absorbance value and knowing     and  l  you can calculate  c. This is the the principle used in many experiments to determine the concentration of a known compound in a particular test sample – for instance monitoring of drug metabolites in the urine of drug takers; monitoring biomolecules produced in the body during particular disease states Beer Lambert Law A =   .c.l
Organic molecules that contain a double bond can absorb UV
phenolphthalein
Retinol
Other conjugated systems that absorb in the visible UV
Typical  absorbtions
A9HL Nuclear magnetic resonance (NMR) spectroscopy
[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],TETRAMETHYLSILANE - TMS The molecule contains four methyl groups attached to a silicon atom in a tetrahedral arrangement.  All the hydrogen atoms are chemically equivalent. PROVIDES THE REFERENCE SIGNAL
Multiplicity & splitting
Number of peaks  =  number of chemically different H’s on adjacent atoms  +  1 1 neighbouring H 2 peaks “doublet” 1:1  2 neighbouring H’s  3 peaks “triplet” 1:2:1 3 neighbouring H’s  4 peaks “quartet” 1:3:3:1 4 neighbouring H’s  5 peaks “quintet” 1:4:6:4:1 Signals for the H in an O-H bond  are unaffected by hydrogens on adjacent atoms - get a singlet MULTIPLICITY (Spin-spin splitting) ,[object Object],[object Object],[object Object]
LOW RESOLUTION - HIGH RESOLUTION HIGH RESOLUTION SPECTRUM OF 1-BROMOPROPANE The broad peaks are split into sharper signals The splitting pattern depends on the number of hydrogen atoms on adjacent atoms ,[object Object],[object Object],[object Object]
INTEGRATION ,[object Object],[object Object],[object Object],[object Object],IMPORTANT: It doesn’t provide the actual number of H’s in each environment, just the ratio Measure the distance between the top and bottom lines. Compare the heights from each signal and make them into a simple ratio.
CONTENTS NMR SPECTROSCOPY “ CENSUS” QUESTIONS - describe where each hydrogen lives - say how many hydrogens live on that atom - say how many  chemically different  hydrogen atoms live on adjacent atoms 1-BROMOPROPANE ATOM UNIQUE DESCRIPTION OF THE POSITION OF THE HYDROGEN ATOMS H’S ON THE ATOM CHEMICALLY DIFFERENT H’S ON ADJACENT ATOMS SIGNAL SPLIT INTO 1 On an end carbon, two away from the carbon with the bromine atom on it 3 2 2+1 =  3 2 On a carbon atom second from the end and one away from the carbon with the bromine atom 2 3+2 =  5 5+1 =  6 3 On an end carbon atom which also has the bromine atom on it 2 2 2+1 =  3 1 2 3
A10HL  Chromatography
This is what a HPLC machine looks like
What does a HLPC chromatogram look like?
Chromatogram of Orange Juice Compounds

Weitere ähnliche Inhalte

Was ist angesagt?

UV Visible Spectroscopy
UV Visible SpectroscopyUV Visible Spectroscopy
UV Visible SpectroscopySimranDhiman12
 
solid phase extraction and application
solid phase extraction and applicationsolid phase extraction and application
solid phase extraction and applicationPiramal Healthcare
 
Nephelometry and Turbidimetry
Nephelometry and TurbidimetryNephelometry and Turbidimetry
Nephelometry and Turbidimetrykumar ganesh
 
Two Diemensional NMR (2D NMR)
Two Diemensional NMR (2D NMR)Two Diemensional NMR (2D NMR)
Two Diemensional NMR (2D NMR)Ali Baig
 
IR spectroscopy
IR spectroscopyIR spectroscopy
IR spectroscopyArun kumar
 
Spin spin coupling and coupling constant
Spin spin coupling and coupling constantSpin spin coupling and coupling constant
Spin spin coupling and coupling constantHimal Barakoti
 
Spectroflourimetry
SpectroflourimetrySpectroflourimetry
SpectroflourimetryXenChisti
 
Instrumentation of IR spectroscopy
Instrumentation of IR spectroscopyInstrumentation of IR spectroscopy
Instrumentation of IR spectroscopyTalha Liaqat
 
UV-visible spectroscopy
UV-visible spectroscopyUV-visible spectroscopy
UV-visible spectroscopyaaaaalok
 
FOURIER -TRANSFORM INFRARED SPECTROMETER [FTIR]
FOURIER -TRANSFORM INFRARED SPECTROMETER [FTIR]	FOURIER -TRANSFORM INFRARED SPECTROMETER [FTIR]
FOURIER -TRANSFORM INFRARED SPECTROMETER [FTIR] Sagar Savale
 
Introduction and Principle of IR spectroscopy
Introduction and Principle of IR spectroscopyIntroduction and Principle of IR spectroscopy
Introduction and Principle of IR spectroscopyRajaram Kshetri
 
spectrofluorimetry ppt
spectrofluorimetry pptspectrofluorimetry ppt
spectrofluorimetry pptseema bisht
 
ATOMIC ABSORPTION SPECTROSCOPY
ATOMIC ABSORPTION SPECTROSCOPYATOMIC ABSORPTION SPECTROSCOPY
ATOMIC ABSORPTION SPECTROSCOPYSUBHASISH DAS
 
Solvents and solvent effect in UV - Vis Spectroscopy, By Dr. Umesh Kumar sh...
Solvents and  solvent effect in UV -  Vis Spectroscopy, By Dr. Umesh Kumar sh...Solvents and  solvent effect in UV -  Vis Spectroscopy, By Dr. Umesh Kumar sh...
Solvents and solvent effect in UV - Vis Spectroscopy, By Dr. Umesh Kumar sh...Dr. UMESH KUMAR SHARMA
 

Was ist angesagt? (20)

Infrared Spectroscopy
Infrared SpectroscopyInfrared Spectroscopy
Infrared Spectroscopy
 
UV Visible Spectroscopy
UV Visible SpectroscopyUV Visible Spectroscopy
UV Visible Spectroscopy
 
solid phase extraction and application
solid phase extraction and applicationsolid phase extraction and application
solid phase extraction and application
 
Nephelometry and Turbidimetry
Nephelometry and TurbidimetryNephelometry and Turbidimetry
Nephelometry and Turbidimetry
 
Two Diemensional NMR (2D NMR)
Two Diemensional NMR (2D NMR)Two Diemensional NMR (2D NMR)
Two Diemensional NMR (2D NMR)
 
U V Visible Spectroscopy
U V Visible SpectroscopyU V Visible Spectroscopy
U V Visible Spectroscopy
 
IR spectroscopy
IR spectroscopyIR spectroscopy
IR spectroscopy
 
Spin spin coupling and coupling constant
Spin spin coupling and coupling constantSpin spin coupling and coupling constant
Spin spin coupling and coupling constant
 
Spectroflourimetry
SpectroflourimetrySpectroflourimetry
Spectroflourimetry
 
HPLC
HPLCHPLC
HPLC
 
Instrumentation of IR spectroscopy
Instrumentation of IR spectroscopyInstrumentation of IR spectroscopy
Instrumentation of IR spectroscopy
 
Dispersive & FTIR
Dispersive & FTIRDispersive & FTIR
Dispersive & FTIR
 
NMR Instrumentation
NMR InstrumentationNMR Instrumentation
NMR Instrumentation
 
UV-visible spectroscopy
UV-visible spectroscopyUV-visible spectroscopy
UV-visible spectroscopy
 
FOURIER -TRANSFORM INFRARED SPECTROMETER [FTIR]
FOURIER -TRANSFORM INFRARED SPECTROMETER [FTIR]	FOURIER -TRANSFORM INFRARED SPECTROMETER [FTIR]
FOURIER -TRANSFORM INFRARED SPECTROMETER [FTIR]
 
Introduction and Principle of IR spectroscopy
Introduction and Principle of IR spectroscopyIntroduction and Principle of IR spectroscopy
Introduction and Principle of IR spectroscopy
 
spectrofluorimetry ppt
spectrofluorimetry pptspectrofluorimetry ppt
spectrofluorimetry ppt
 
ATOMIC ABSORPTION SPECTROSCOPY
ATOMIC ABSORPTION SPECTROSCOPYATOMIC ABSORPTION SPECTROSCOPY
ATOMIC ABSORPTION SPECTROSCOPY
 
Solvents and solvent effect in UV - Vis Spectroscopy, By Dr. Umesh Kumar sh...
Solvents and  solvent effect in UV -  Vis Spectroscopy, By Dr. Umesh Kumar sh...Solvents and  solvent effect in UV -  Vis Spectroscopy, By Dr. Umesh Kumar sh...
Solvents and solvent effect in UV - Vis Spectroscopy, By Dr. Umesh Kumar sh...
 
Spectrofluorimetry
SpectrofluorimetrySpectrofluorimetry
Spectrofluorimetry
 

Andere mochten auch

RADIOISOTOPES AND CLINICAL USES
RADIOISOTOPES AND CLINICAL USESRADIOISOTOPES AND CLINICAL USES
RADIOISOTOPES AND CLINICAL USESsugash
 
Instrumental analysis
Instrumental analysisInstrumental analysis
Instrumental analysisGaurav Kr
 
Nmr spectroscopy
Nmr spectroscopyNmr spectroscopy
Nmr spectroscopyAsma Ashraf
 
Handling OOS results
Handling OOS resultsHandling OOS results
Handling OOS resultsanezlin
 
Genomic in situ Hybridization
Genomic in situ HybridizationGenomic in situ Hybridization
Genomic in situ HybridizationKuldeep Sharma
 
Fluorescence in situ Hybridization FISH #glok92
Fluorescence in situ Hybridization FISH #glok92Fluorescence in situ Hybridization FISH #glok92
Fluorescence in situ Hybridization FISH #glok92glok Productions
 
Nuclear magnetic resonance ( NMR)
Nuclear magnetic resonance ( NMR)Nuclear magnetic resonance ( NMR)
Nuclear magnetic resonance ( NMR)Ammar Babar
 
Fluorescent in-situ Hybridization (FISH)
Fluorescent in-situ Hybridization (FISH)Fluorescent in-situ Hybridization (FISH)
Fluorescent in-situ Hybridization (FISH)BioGenex
 
NMR Spectroscopy
NMR SpectroscopyNMR Spectroscopy
NMR Spectroscopytabirsir
 
Nuclear Magnetic Resonance Spectroscopy
Nuclear Magnetic Resonance SpectroscopyNuclear Magnetic Resonance Spectroscopy
Nuclear Magnetic Resonance SpectroscopyASUTOSH MOHAPATRA
 
Fish(flourescent in-situ hybridization)
Fish(flourescent in-situ hybridization)Fish(flourescent in-situ hybridization)
Fish(flourescent in-situ hybridization)naren
 
Integration of chromatographic peaks
Integration of chromatographic peaksIntegration of chromatographic peaks
Integration of chromatographic peaksdeepak mishra
 

Andere mochten auch (20)

RADIOISOTOPES AND CLINICAL USES
RADIOISOTOPES AND CLINICAL USESRADIOISOTOPES AND CLINICAL USES
RADIOISOTOPES AND CLINICAL USES
 
Instrumental analysis
Instrumental analysisInstrumental analysis
Instrumental analysis
 
Radioisotopes
RadioisotopesRadioisotopes
Radioisotopes
 
Radioactive isotopes in medicine
Radioactive isotopes in medicineRadioactive isotopes in medicine
Radioactive isotopes in medicine
 
Nmr spectroscopy
Nmr spectroscopyNmr spectroscopy
Nmr spectroscopy
 
Handling OOS results
Handling OOS resultsHandling OOS results
Handling OOS results
 
Radio isotopes
Radio isotopesRadio isotopes
Radio isotopes
 
Genomic in situ Hybridization
Genomic in situ HybridizationGenomic in situ Hybridization
Genomic in situ Hybridization
 
Fluorescence in situ Hybridization FISH #glok92
Fluorescence in situ Hybridization FISH #glok92Fluorescence in situ Hybridization FISH #glok92
Fluorescence in situ Hybridization FISH #glok92
 
Chromatography
Chromatography Chromatography
Chromatography
 
Nmr ppt.
Nmr ppt.Nmr ppt.
Nmr ppt.
 
Nuclear magnetic resonance ( NMR)
Nuclear magnetic resonance ( NMR)Nuclear magnetic resonance ( NMR)
Nuclear magnetic resonance ( NMR)
 
Autoradiography
Autoradiography Autoradiography
Autoradiography
 
Fluorescent in-situ Hybridization (FISH)
Fluorescent in-situ Hybridization (FISH)Fluorescent in-situ Hybridization (FISH)
Fluorescent in-situ Hybridization (FISH)
 
NMR Spectroscopy
NMR SpectroscopyNMR Spectroscopy
NMR Spectroscopy
 
Nuclear Magnetic Resonance Spectroscopy
Nuclear Magnetic Resonance SpectroscopyNuclear Magnetic Resonance Spectroscopy
Nuclear Magnetic Resonance Spectroscopy
 
Tracer technique
Tracer techniqueTracer technique
Tracer technique
 
Nmr spectroscopy
Nmr spectroscopyNmr spectroscopy
Nmr spectroscopy
 
Fish(flourescent in-situ hybridization)
Fish(flourescent in-situ hybridization)Fish(flourescent in-situ hybridization)
Fish(flourescent in-situ hybridization)
 
Integration of chromatographic peaks
Integration of chromatographic peaksIntegration of chromatographic peaks
Integration of chromatographic peaks
 

Ähnlich wie Analical chemistry ok1294986152

ستخدام جهاز المطياف الضوئي لتعيين القياسات الكميه في التحليلات البايو كيميائية
ستخدام جهاز المطياف الضوئي لتعيين القياسات الكميه في التحليلات البايو كيميائيةستخدام جهاز المطياف الضوئي لتعيين القياسات الكميه في التحليلات البايو كيميائية
ستخدام جهاز المطياف الضوئي لتعيين القياسات الكميه في التحليلات البايو كيميائيةasawer zayad
 
UV- Visible Spectroscopy
UV- Visible SpectroscopyUV- Visible Spectroscopy
UV- Visible SpectroscopyROHIT
 
12 02-09-12-24-23-1390-sampathkumar
12 02-09-12-24-23-1390-sampathkumar12 02-09-12-24-23-1390-sampathkumar
12 02-09-12-24-23-1390-sampathkumarDONIKAMARKANDE
 
UV-visible spectrophotometry ppt
UV-visible spectrophotometry ppt UV-visible spectrophotometry ppt
UV-visible spectrophotometry ppt rdeepthi1
 
UV ray spectrophotometer
UV ray spectrophotometerUV ray spectrophotometer
UV ray spectrophotometerGoa App
 
Colorimetry and atomic absorption spectroscopy
Colorimetry and atomic absorption spectroscopy Colorimetry and atomic absorption spectroscopy
Colorimetry and atomic absorption spectroscopy O.P PARIHAR
 
SEMINAR ON UV SPECTROSCOPY
SEMINAR ON UV SPECTROSCOPYSEMINAR ON UV SPECTROSCOPY
SEMINAR ON UV SPECTROSCOPYNITIN KANWALE
 
uv -visible spectroscopy
uv -visible spectroscopyuv -visible spectroscopy
uv -visible spectroscopyyogitamandlik2
 
spectrophotometry, ultra violet absorption, infra red atomic absorption.
spectrophotometry, ultra violet absorption, infra red atomic absorption.spectrophotometry, ultra violet absorption, infra red atomic absorption.
spectrophotometry, ultra violet absorption, infra red atomic absorption.priya tamang
 
UV rays
UV rays UV rays
UV rays Goa App
 
UV visible Specrosopy and applications
UV visible Specrosopy and applicationsUV visible Specrosopy and applications
UV visible Specrosopy and applicationsNAFIHHASSANMEHABANI
 
Biomolecular andcellularresearchdevices fin
Biomolecular andcellularresearchdevices finBiomolecular andcellularresearchdevices fin
Biomolecular andcellularresearchdevices finMUBOSScz
 

Ähnlich wie Analical chemistry ok1294986152 (20)

Prabhakar singh ii sem-paper v-colorimeter & spectrophotometer
Prabhakar singh  ii sem-paper v-colorimeter & spectrophotometerPrabhakar singh  ii sem-paper v-colorimeter & spectrophotometer
Prabhakar singh ii sem-paper v-colorimeter & spectrophotometer
 
Presentation2
Presentation2Presentation2
Presentation2
 
UV VISIBLE Spectroscopy
UV VISIBLE SpectroscopyUV VISIBLE Spectroscopy
UV VISIBLE Spectroscopy
 
ستخدام جهاز المطياف الضوئي لتعيين القياسات الكميه في التحليلات البايو كيميائية
ستخدام جهاز المطياف الضوئي لتعيين القياسات الكميه في التحليلات البايو كيميائيةستخدام جهاز المطياف الضوئي لتعيين القياسات الكميه في التحليلات البايو كيميائية
ستخدام جهاز المطياف الضوئي لتعيين القياسات الكميه في التحليلات البايو كيميائية
 
UV- Visible Spectroscopy
UV- Visible SpectroscopyUV- Visible Spectroscopy
UV- Visible Spectroscopy
 
Turbidity usp
Turbidity uspTurbidity usp
Turbidity usp
 
12 02-09-12-24-23-1390-sampathkumar
12 02-09-12-24-23-1390-sampathkumar12 02-09-12-24-23-1390-sampathkumar
12 02-09-12-24-23-1390-sampathkumar
 
Uv vis absorbance measurement
Uv vis absorbance measurementUv vis absorbance measurement
Uv vis absorbance measurement
 
UV-visible spectrophotometry ppt
UV-visible spectrophotometry ppt UV-visible spectrophotometry ppt
UV-visible spectrophotometry ppt
 
UV-VIS Spectroscopy
UV-VIS SpectroscopyUV-VIS Spectroscopy
UV-VIS Spectroscopy
 
UV ray spectrophotometer
UV ray spectrophotometerUV ray spectrophotometer
UV ray spectrophotometer
 
Colorimetry and atomic absorption spectroscopy
Colorimetry and atomic absorption spectroscopy Colorimetry and atomic absorption spectroscopy
Colorimetry and atomic absorption spectroscopy
 
SEMINAR ON UV SPECTROSCOPY
SEMINAR ON UV SPECTROSCOPYSEMINAR ON UV SPECTROSCOPY
SEMINAR ON UV SPECTROSCOPY
 
uv.pptx
uv.pptxuv.pptx
uv.pptx
 
uv -visible spectroscopy
uv -visible spectroscopyuv -visible spectroscopy
uv -visible spectroscopy
 
spectrophotometry, ultra violet absorption, infra red atomic absorption.
spectrophotometry, ultra violet absorption, infra red atomic absorption.spectrophotometry, ultra violet absorption, infra red atomic absorption.
spectrophotometry, ultra violet absorption, infra red atomic absorption.
 
UV rays
UV rays UV rays
UV rays
 
UV visible Specrosopy and applications
UV visible Specrosopy and applicationsUV visible Specrosopy and applications
UV visible Specrosopy and applications
 
UV Visible Spectrometry
UV Visible SpectrometryUV Visible Spectrometry
UV Visible Spectrometry
 
Biomolecular andcellularresearchdevices fin
Biomolecular andcellularresearchdevices finBiomolecular andcellularresearchdevices fin
Biomolecular andcellularresearchdevices fin
 

Mehr von Navin Joshi

Numbers ok1296542354
Numbers   ok1296542354Numbers   ok1296542354
Numbers ok1296542354Navin Joshi
 
Properties drill ok1296542500
Properties drill  ok1296542500Properties drill  ok1296542500
Properties drill ok1296542500Navin Joshi
 
Prime numbers ok1296542459
Prime numbers  ok1296542459Prime numbers  ok1296542459
Prime numbers ok1296542459Navin Joshi
 
Use of halogen ok1294998147
Use of halogen  ok1294998147Use of halogen  ok1294998147
Use of halogen ok1294998147Navin Joshi
 
Triangle classification
Triangle classificationTriangle classification
Triangle classificationNavin Joshi
 
Treasure hunt sequences1296542856
Treasure hunt sequences1296542856Treasure hunt sequences1296542856
Treasure hunt sequences1296542856Navin Joshi
 
Transition elements opt ok1294998077
Transition elements opt  ok1294998077Transition elements opt  ok1294998077
Transition elements opt ok1294998077Navin Joshi
 
Thermochemistry ok1294993378
Thermochemistry   ok1294993378Thermochemistry   ok1294993378
Thermochemistry ok1294993378Navin Joshi
 
Stoichiometry ok1294993172
Stoichiometry   ok1294993172Stoichiometry   ok1294993172
Stoichiometry ok1294993172Navin Joshi
 
Squares and square roots ok1296542788
Squares and square roots  ok1296542788Squares and square roots  ok1296542788
Squares and square roots ok1296542788Navin Joshi
 
Solving equations ok1296542729
Solving equations   ok1296542729Solving equations   ok1296542729
Solving equations ok1296542729Navin Joshi
 
Solving equations
Solving equationsSolving equations
Solving equationsNavin Joshi
 
Slope ok12965426381296619795
Slope   ok12965426381296619795Slope   ok12965426381296619795
Slope ok12965426381296619795Navin Joshi
 
Simplifying expressions ok1296542578
Simplifying expressions  ok1296542578Simplifying expressions  ok1296542578
Simplifying expressions ok1296542578Navin Joshi
 
Polymer ok1294992673
Polymer   ok1294992673Polymer   ok1294992673
Polymer ok1294992673Navin Joshi
 
Physical sepration ok1294992218
Physical sepration   ok1294992218Physical sepration   ok1294992218
Physical sepration ok1294992218Navin Joshi
 
Periodic table1292657304
Periodic table1292657304Periodic table1292657304
Periodic table1292657304Navin Joshi
 
Noble gases opt ok1294991905
Noble gases opt  ok1294991905Noble gases opt  ok1294991905
Noble gases opt ok1294991905Navin Joshi
 

Mehr von Navin Joshi (20)

Numbers ok1296542354
Numbers   ok1296542354Numbers   ok1296542354
Numbers ok1296542354
 
Properties drill ok1296542500
Properties drill  ok1296542500Properties drill  ok1296542500
Properties drill ok1296542500
 
Prime numbers ok1296542459
Prime numbers  ok1296542459Prime numbers  ok1296542459
Prime numbers ok1296542459
 
Use of halogen ok1294998147
Use of halogen  ok1294998147Use of halogen  ok1294998147
Use of halogen ok1294998147
 
Triangle classification
Triangle classificationTriangle classification
Triangle classification
 
Treasure hunt sequences1296542856
Treasure hunt sequences1296542856Treasure hunt sequences1296542856
Treasure hunt sequences1296542856
 
Transition elements opt ok1294998077
Transition elements opt  ok1294998077Transition elements opt  ok1294998077
Transition elements opt ok1294998077
 
Thermochemistry ok1294993378
Thermochemistry   ok1294993378Thermochemistry   ok1294993378
Thermochemistry ok1294993378
 
Stoichiometry ok1294993172
Stoichiometry   ok1294993172Stoichiometry   ok1294993172
Stoichiometry ok1294993172
 
Squares and square roots ok1296542788
Squares and square roots  ok1296542788Squares and square roots  ok1296542788
Squares and square roots ok1296542788
 
Solving equations ok1296542729
Solving equations   ok1296542729Solving equations   ok1296542729
Solving equations ok1296542729
 
Solving equations
Solving equationsSolving equations
Solving equations
 
Slope ok12965426381296619795
Slope   ok12965426381296619795Slope   ok12965426381296619795
Slope ok12965426381296619795
 
Simplifying expressions ok1296542578
Simplifying expressions  ok1296542578Simplifying expressions  ok1296542578
Simplifying expressions ok1296542578
 
Prime numbers
Prime numbersPrime numbers
Prime numbers
 
Ppt0000000
Ppt0000000Ppt0000000
Ppt0000000
 
Polymer ok1294992673
Polymer   ok1294992673Polymer   ok1294992673
Polymer ok1294992673
 
Physical sepration ok1294992218
Physical sepration   ok1294992218Physical sepration   ok1294992218
Physical sepration ok1294992218
 
Periodic table1292657304
Periodic table1292657304Periodic table1292657304
Periodic table1292657304
 
Noble gases opt ok1294991905
Noble gases opt  ok1294991905Noble gases opt  ok1294991905
Noble gases opt ok1294991905
 

Analical chemistry ok1294986152

  • 2. A2 Principles of spectroscopy
  • 4.
  • 5. Absorption spectra have parts ‘missing’. In the diagram below the troughs indicate energy absorbed by the molecules
  • 6. Observing with a hand held spectroscope gives you evidence for line emission spectra similar to the one shown below Here light is being emitted as the excited electrons drop down to lower ‘allowed’ energy levels.
  • 7.
  • 8. • a beam of infra red radiation is passed through the sample • a similar beam is passed through the reference cell • the frequency of radiation is varied • bonds vibrating with a similar frequency absorb the radiation • the amount of radiation absorbed by the sample is compared with the reference • the results are collected, stored and plotted The Infra-red Spectrophotometer
  • 9. SYMMETRIC STRETCHING BENDING AND STRETCHING IN WATER MOLECULES
  • 10. ASYMMETRIC STRETCHING BENDING AND STRETCHING IN WATER MOLECULES
  • 11. BENDING AND STRETCHING IN WATER MOLECULES BENDING
  • 12. Vertical axis Absorbance the stronger the absorbance the larger the peak Horizontal axis Frequency wavenumber (waves per centimetre) / cm -1 Wavelength microns (m); 1 micron = 1000 nanometres INFRA RED SPECTRA - INTERPRETATION
  • 13. FINGERPRINT REGION • organic molecules have a lot of C-C and C-H bonds within their structure • spectra obtained will have peaks in the 1400 cm -1 to 800 cm -1 range • this is referred to as the “fingerprint” region • the pattern obtained is characteristic of a particular compound the frequency of any absorption is also affected by adjoining atoms or groups.
  • 14. IR SPECTRUM OF A CARBONYL COMPOUND • carbonyl compounds show a sharp, strong absorption between 1700 and 1760 cm -1 • this is due to the presence of the C=O bond
  • 15. IR SPECTRUM OF AN ALCOHOL • alcohols show a broad absorption between 3200 and 3600 cm -1 • this is due to the presence of the O-H bond
  • 16. WHAT IS IT! O-H STRETCH C=O STRETCH ALCOHOL ALDEHYDE CARBOXYLIC ACID One can tell the difference between alcohols, aldehydes and carboxylic acids by comparison of their spectra. O-H STRETCH C=O STRETCH AND
  • 18.
  • 19. An outline of what happens in a mass spectrometer
  • 20. Peaks appear due to characteristic fragments (e.g. 29 due to C 2 H 5 + ) and differences between two peaks also indicates the loss of certain units (e.g. 18 for H 2 O, 28 for CO and 44 for CO 2 ). Many of the fragments do not show up themselves on the spectrum because they are not ions.
  • 21.
  • 23. A5 Nuclear magnetic resonance (NMR) spectroscopy
  • 24.
  • 25.
  • 26.
  • 27.
  • 28.
  • 29.
  • 30. How NMR is used in body scanners
  • 31. A6 Atomic absorption (AA) spectroscopy
  • 32. This is what an Atomic Absorption spectroscopic machine looks like
  • 33. This is the basic set up for AAS
  • 36.
  • 37. A = ε bc In this equation, the absorbance (A) of the solution is directly proportional to the concentration (c) in moles/Liter, the pathlength (b) in cm-1 and the molar absorptivity (e ) in Lcm-1mol-1. Under the conditions of this experiment, the molar absorptivity and the path length are constant. Thus the absorbance of a solution is directly proportional to the concentration of solution. This concentration is expressed in molarity or moles/Liter.
  • 38. This equation and relationship between absorbance and concentration can be used to of several samples of a particular chemical on the x-axis and the corresponding maximum absorbance on the y-axis, a Beer’s Law Plot is obtained. 
  • 39. The Plot can then be used to determine an unknown concentration of the same chemical. At dilute concentrations, many chemical solutions obey Beer’s Law, resulting in a straight line plot with the general equation for a straight line y = mx + b .
  • 40. To find the unknown concentration of a solution, use the equation for a straight line and solve for x. y = mx + b Sample calculation: Using the Beer's Law Plot above, determine the unknown concentration of a solution with an absorbance reading of .600. In this example, the slope (m) is 6.414 and the intercept ( b) is -7.99 x 10 -3. Solving for x, .600 = 6.414 x - 0.00799 x = 0.095 M
  • 42.
  • 43.
  • 44.
  • 45.
  • 46.
  • 47.
  • 48.
  • 50. Observing the Chromatograms Concentration of Isopropanol 0% 20% 50% 70% 100%
  • 51. Kinds of Chromatography 1. Paper Chromatography   2. Column Chromatography   3. Thin-layer Chromatography
  • 52. LIQUID COLUMN CHROMATOGRAPHY A sample mixture is passed through a column packed with solid particles which may or may not be coated with another liquid. With the proper solvents, packing conditions, some components in the sample will travel the column more slowly than others resulting in the desired separation.
  • 53.
  • 55.
  • 56. A8HL Visible and ultraviolet (UV-Vis) spectroscopy
  • 57. COLOURED IONS Theory ions with a d 10 (full) or d 0 (empty) configuration are colourless ions with partially filled d-orbitals tend to be coloured it is caused by the ease of transition of electrons between energy levels energy is absorbed when an electron is promoted to a higher level the frequency of light is proportional to the energy difference ions with d 10 (full) Cu + ,Ag + Zn 2+ or d 0 (empty) Sc 3+ configuration are colourless e.g. titanium(IV) oxide TiO 2 is white colour depends on ... transition element oxidation state ligand coordination number A characteristic of transition metals is their ability to form coloured compounds
  • 58. SPLITTING OF 3d ORBITALS Placing ligands around a central ion causes the energies of the d orbitals to change Some of the d orbitals gain energy and some lose energy In an octahedral complex, two ( z 2 and x 2 -y 2 ) go higher and three go lower In a tetrahedral complex, three ( xy, xz and yz ) go higher and two go lower Degree of splitting depends on the CENTRAL ION and the LIGAND The energy difference between the levels affects how much energy is absorbed when an electron is promoted. The amount of energy governs the colour of light absorbed. 3d 3d OCTAHEDRAL TETRAHEDRAL
  • 59. COLOURED IONS Absorbed colour nm Observed colour nm VIOLET 400 GREEN-YELLOW 560 BLUE 450 YELLOW 600 BLUE-GREEN 490 RED 620 YELLOW-GREEN 570 VIOLET 410 YELLOW 580 DARK BLUE 430 ORANGE 600 BLUE 450 RED 650 GREEN 520 The observed colour of a solution depends on the wavelengths absorbed Copper sulphate solution appears blue because the energy absorbed corresponds to red and yellow wavelengths. Wavelengths corresponding to blue light aren’t absorbed. WHITE LIGHT GOES IN SOLUTION APPEARS BLUE ENERGY CORRESPONDING TO THESE COLOURS IS ABSORBED
  • 60. COLOURED IONS a solution of copper(II)sulphate is blue because red and yellow wavelengths are absorbed white light blue and green not absorbed
  • 61. COLOURED IONS a solution of copper(II)sulphate is blue because red and yellow wavelengths are absorbed
  • 62. Ultraviolet (UV) Spectroscopy – Use and Analysis Of all the forms of radiation that go to make up the electromagnetic spectrum UV is probably the most familiar to the general public (after the radiation associated with visible light which is, for the most part, taken for granted). UV radiation is widely known as something to be aware of in hot weather in having a satisfactory effect of tanning the skin but which also has the capacity to damage skin cells to the extent that skin cancer is a direct consequence of overexposure to UV radiation. This damage is associated with the high energy of UV radiation which is directly related to its high frequency and its low wavelength (see the equations below). This is designed to introduce you to UV spectroscopy and give you enough information to ensure that you understand how you can use the technique as a quantitative as appose to a qualitative method.. c =  E = h  E = (hc)/  E  1/  E = energy; c = speed of light;  = wavelength;  = frequency; h = Planck’s constant
  • 63. Ultraviolet (UV) Spectroscopy – Use and Analysis When continuous wave radiation is passed through a prism a diffraction pattern is produced (called a spectrum) made up of all the wavelengths associated with the incident radiation. When continuous wave radiation passes through a transparent material (solid or liquid) some of the radiation might be absorbed by that material. This slide is part automatically animated – if animation does not occur click left hand mouse button. Radiation source Diffraction prism Spectrum Transparent material that absorbs some radiation Spectrum with ‘gaps’ in it If, having passed through the material, the beam is diffracted by passing through a prism it will produce a light spectrum that has gaps in it (caused by the absorption of radiation by the transparent material through which is passed). The effect of absorption of radiation on the transparent material is to change is from a low energy state (called the ground state) to a higher energy state (called the excited state). The difference between all the spectroscopic techniques is that they use different wavelength radiation that has different associated energy which can cause different modes of excitation in a molecule. For instance, with infra red spectroscopy the low energy radiation simply causes bonds to bend and stretch when a molecule absorbs the radiation. With high energy UV radiation the absorption of energy causes transition of bonding electrons from a low energy orbital to a higher energy orbital. The energy of the ‘missing’ parts of the spectrum corresponds exactly to the energy difference between the orbitals involved in the transition.
  • 64. Ultraviolet (UV) Spectroscopy – Use and Analysis    *  * n Occupied Energy Levels Unoccupied Energy Levels The bonding orbitals with which you are familiar are the  -bonding orbitals typified by simple alkanes. These are low energy (that is, stable). Next (in terms of increasing energy) are the  -bonding orbitals present in all functional groups that contain double and triple bonds ( e.g. carbonyl groups and alkenes). Higher energy still are the non-bonding orbitals present on atoms that have lone pair(s) of electrons (oxygen, nitrogen, sulfur and halogen containing compounds). All of the above 3 kinds of orbitals may be occupied in the ground state. Two other sort of orbitals, called antibonding orbitals, can only be occupied by an electron in an excited state (having absorbed UV for instance). These are the  * and  * orbitals (the * denotes antibonding). Although you are not too familiar with the concept of an antibonding orbital just remember the following – whilst electron density in a bonding orbital is a stabilising influence it is a destabilising influence (bond weakening) in an antibonding orbital. Antibonding orbitals are unoccupied in the ground state UV A transition of an electron from occupied to an unoccupied energy level can be caused by UV radiation. Not all transitions are allowed but the definition of which are and which are not are beyond the scope of this tutorial. For the time being be aware that commonly seen transitions are  to  * which correctly implies that UV is useful with compounds containing double bonds. A schematic of the transition of an electron from  to  * is shown on the left. Increasing energy
  • 65. Ultraviolet (UV) Spectroscopy – The Output The output from a UV scanning spectrometer is not the most informative looking piece of data!! It looks like a series of broad humps of varying height. An example is shown below. Decreasing wavelength in nm Increasing absorbance * *Absorbance has no units – it is actually the logarithm of the ratio of light intensity incident on the sample divided by the light intensity leaving the sample. There are two particular strengths of UV (i) it is very sensitive (ii) it is very useful in determining the quantity of a known compound in a solution of unknown concentration. It is not so useful in determining structure although it has been used in this way in the past. The concentration of a sample is related to the absorbance according to the Beer Lambert Law which is described above. A = absorbance ; c = concentration in moles l -1 ; l = pathlength in cm ;  = molar absorptivity (also known as extinction coefficient ) which has units of moles -1 L cm -1 . Beer Lambert Law A =  .c.l
  • 66. Ultraviolet (UV) Spectroscopy – Analysing the Output Handling samples of known concentration If you know the structure of your compound X and you wish to acquire UV data you would do the following. Prepare a known concentration solution of your sample. Run a UV spectrum (typically from 500 down to 220 nm). From the spectrum read off the wavelength values for each of the maxima of the spectra (see left) Read off the absorbance values of each of the maxima (see left). Then using the known concentration (in moles L -1 ) and the known pathlength (1 cm) calculate the molar absorptivity (  ) for each of the maxima. Finally quote the data as follows (for instance for the largest peak in the spectrum to the left and assuming a concentration of 0.0001 moles L -1 ).  max = 487nm A= 0.75  = 0.75 /(0.001 x 1.0) = 7500 moles -1 L cm -1 Determining concentration of samples with known molar absorptivity (  ). Having used the calculation in the yellow box to work out the molar absorptivity of a compound you can now use UV to determine the concentration of compound X in other samples (provided that these sample only contain pure X). Simply run the UV of the unknown and take the absorbance reading at the maxima for which you have a known value of  . In the case above this is at the peak with the highest wavelength (see above). Having found the absorbance value and knowing  and l you can calculate c. This is the the principle used in many experiments to determine the concentration of a known compound in a particular test sample – for instance monitoring of drug metabolites in the urine of drug takers; monitoring biomolecules produced in the body during particular disease states Beer Lambert Law A =  .c.l
  • 67. Organic molecules that contain a double bond can absorb UV
  • 70. Other conjugated systems that absorb in the visible UV
  • 72. A9HL Nuclear magnetic resonance (NMR) spectroscopy
  • 73.
  • 74.
  • 76.
  • 77.
  • 78.
  • 79. CONTENTS NMR SPECTROSCOPY “ CENSUS” QUESTIONS - describe where each hydrogen lives - say how many hydrogens live on that atom - say how many chemically different hydrogen atoms live on adjacent atoms 1-BROMOPROPANE ATOM UNIQUE DESCRIPTION OF THE POSITION OF THE HYDROGEN ATOMS H’S ON THE ATOM CHEMICALLY DIFFERENT H’S ON ADJACENT ATOMS SIGNAL SPLIT INTO 1 On an end carbon, two away from the carbon with the bromine atom on it 3 2 2+1 = 3 2 On a carbon atom second from the end and one away from the carbon with the bromine atom 2 3+2 = 5 5+1 = 6 3 On an end carbon atom which also has the bromine atom on it 2 2 2+1 = 3 1 2 3
  • 81. This is what a HPLC machine looks like
  • 82. What does a HLPC chromatogram look like?
  • 83. Chromatogram of Orange Juice Compounds