• Lower system capital cost.
• A PEMS can be configured, delivered and installed in 30-
45 days.
Installation of a PEMS requires the installation of a single
computer with the DAS/PEMS software installed and
interfaced to the boiler control system. Typically a one day
installation and start up process.
• PEMS have lower startup costs, normally one day
including DAS.
• PEMS require less on site training.
PEMS training is usually 1 to 1 1⁄2 days plus DAS training.
• PEMS should require no on site emergency service.
A direct modem to the system takes care of 99% of all
service requirements.
• PEMS do not require dual range analyzers.
CMC PEMS measure the full dynamic range of emissions
from a source, including start up to shut down.
• PEMS do not require EPA protocol calibration gases,
piping, wiring, gas regulators or software to operate the
auto-calibration sequence.
CMC PEMS analyzers do have auto calibration just like a
CEMS.
• PEMS require no air source.
• PEMS have no ongoing preventative maintenance
requirements as do CEMS.
The only related maintenance for a PEMS is a periodic
cleaning of the PEMS computer. Normal maintenance and
calibration of process instruments that provide data to the
PEMS is required. This maintenance should already be
ongoing within a plant to maintain maximum efficiency
and output; therefore, it is not considered an additional
associated cost.
• PEMS have higher data availability which should normally
approach 100%.
The PEMS does not rely on any one process input to
maintain system uptime or accuracy of emissions quality.
The PEMS uses numerous inputs for a robust data base.
Even with a PEMS failure the data from the DCS inputs for
the predictions still reside within the DCS. This data can be
retrieved, calculated, and back filled by the PEMS when
brought back on line. Therefore very little if any down time
or missing data should ever be reported.
• PEMS can display emission process and combustion
efficiency outputs.
• PEMS can be used to determine the source of excess
emissions.
Combustion input parameter(s) that are out of normal
range can be identified and alarmed for immediate action
and provide a trail to the diagnosis of excess emissions.
• PEMS require no field hardware or additional equipment
beyond the plant or process control system.
In fact, the PEMS in some cases can run on a control
system computer and completely eliminate the need for
additional hardware.
• PEMS maintenance and service is minimal.
A PEMS annual service contracts after warranty period
typically runs $300.00 per month, which includes
maintenance, regulatory and software upgrades. PEMS
maintenance and quarterly audits with onsite support for
report generation run $750.00 to $1000.00 per month
including emergency support with the annual service
contract.
• A CMC PEMS provides accuracy that is equal to that of a
CEMS.
PEMS inherently do not drift. PEMS rely on process inputs
and instruments that typically drift no more than 0.5 to 1%
per year. Typical models utilize 12 or more input
parameters that are in some cases redundant. The
resulting emissions prediction is resilient to input failure
and drift, such that no single input parameter is critical to
the accuracy of the stated emission.
• The PEMS analyzer is not vulnerable to obsolescence.
CMC PEMS are continually upgraded for any new
regulatory changes or software upgrades through
inexpensive ongoing service contracts.
Typically $300.00 per month.
• PEMS require no on site spare parts or consumable spare
parts.
TypicalCEMS
CEMS
• PEMS typically cost much less than CEMS (purchase price
is even lower if a CEMS is on site to provide QA’d
emissions data for PEMS model)
• Depending on complexity and location of the CEMS,
delivery is generally 12- 14 weeks
and installation can take 7 to 14 days using various skilled
trades (electrical, mechanical, computer) to install ports,
probes, umbilical / trays, CEMS rack, gas cylinders, cylinder
racks, gas tubing runs, drain and exhaust lines, plus
interconnecting wiring. CEMS installation may cost more
than the CEMS equipment.
• CEMS normal start up is 2-4 days, depending on
complexity.
• CEMS vendors typically offer 3 day introductory system
training.
(Probe, sample conditioner, analyzers, controller.) In depth
training is an additional 5 days. DAS training is usually
another 2 days.
• On site emergency service for a CEMS is inevitable.
Rates run $1200.00 to $1600.00 per day plus portal to
portal expenses.
• CEMS may be required to have dual ranges to cover the
entire range of operation.
If required the system will need additional calibration
gases, hardware and software.
• CEMS require calibration systems and the on going
purchase of EPA Protocol Gases.
Cylinders of calibration gases also require safe storage and
supplier documentation is necessary. No more demurrage
expenses with a PEMS.
• CEMS require air sources generally of instrument grade.
The air is required for probe blow back and or probe
dilution air. CEMS can require expansion and additional
maintenance to the plant air supply in many cases.
• CEMS require daily, monthly, quarterly, semi and annual
maintenance.
Consumable and spare parts inventories are required to
maintain uptime. (Spares are generally 7-10% the cost of
the system.) Specifically trained personnel are required to
perform maintenance on CEMS with on call duties usually
required.
• CEMS typically are considered doing well if they maintain
95% uptime which is a minimum requirement.
If an analyzer fails (NOx, CO or O2 etc) or a critical
component fails the system is consider down and down
time is logged. When a CEMS analyzer or critical
component fails the system has no capability to retrieve
any missing data and data substitution may be required.
• CEMS do not.
CEMS provide outputs of stack emissions and do not
typically provide process data or source efficiency beyond
unit load, fuel feed, or fuel consumption data.
• CEMS do not provide any insight as to the cause of an
excess emission or the ability to facilitate process control
or correction of the problem.>
CEMS cannot point the operator to the cause or solution of
excess emissions.
• CEMS can, and do, require external equipment.
Cabinets with HVAC, environmentally controlled shelters
or clean rooms must be provided which can take up a
considerable footprint and eliminate valuable space for
other process equipment.
• CEMS annual service contracts typically cost $1000.00 to
$2500.00 per month plus portal to portal
expenses. (depending on complexity)
They normally do not include emergency service, daily,
weekly or monthly maintenance, such as changing gas
bottles, unless specifically requested at an additional cost.
Contracts that include a quarterly site visit, quarterly
cylinder gas audits, and emergency support for CEMS are
also priced at an additional cost.
• CEMS analyzers are designed to drift no more than 1-2%
daily. Long-term CEMS drift is generally experienced
through contamination of sample transport and the
sampling train.
Total system drift is associated with the sampling probe,
transport / conditioning system, sample line, temperature
control, ambient conditions and specified analyzer drift.
Each of these components contribute to a total system
drift or inaccuracy.
• CEMS are always vulnerable to analyzer obsolescence and
replacement. The replacement of 2 analyzers can be
equal to the purchase of a PEMS system.
Two of the main suppliers of analyzers have both replaced
existing analyzers with new models and cancelled support
over the last ten years.
• CEMS require spares and consumable spare parts to
maintain performance and up time requirements and are
a sizable ongoing expense.

Weitere ähnliche Inhalte

Was ist angesagt?

Power Plant Major Losses
Power Plant Major LossesPower Plant Major Losses
Power Plant Major Losses
guest81e1c7
 
processoptimization-rawmillcoalmill-moduleday2-230314110558-e03314c6.pdf
processoptimization-rawmillcoalmill-moduleday2-230314110558-e03314c6.pdfprocessoptimization-rawmillcoalmill-moduleday2-230314110558-e03314c6.pdf
processoptimization-rawmillcoalmill-moduleday2-230314110558-e03314c6.pdf
Santosh190549
 
DESIGN OF AIR PRE HEATER AND ECONOMIZER
DESIGN OF AIR PRE HEATER AND ECONOMIZERDESIGN OF AIR PRE HEATER AND ECONOMIZER
DESIGN OF AIR PRE HEATER AND ECONOMIZER
Gopi Chand
 
04 fuels & combustion calculation09
04 fuels & combustion calculation0904 fuels & combustion calculation09
04 fuels & combustion calculation09
Ravi shankar
 
Water Conservation - Cooling Tower Management Overview
Water Conservation - Cooling Tower Management Overview Water Conservation - Cooling Tower Management Overview
Water Conservation - Cooling Tower Management Overview
brentmwhite
 
SULFUR RECOVERY UNIT DESIGN
SULFUR RECOVERY UNIT DESIGNSULFUR RECOVERY UNIT DESIGN
SULFUR RECOVERY UNIT DESIGN
Tosin Orimoyegun
 

Was ist angesagt? (20)

Clinker cooler's efficiency
Clinker cooler's efficiencyClinker cooler's efficiency
Clinker cooler's efficiency
 
Natural gas sweetening using MDEA
Natural gas sweetening using MDEANatural gas sweetening using MDEA
Natural gas sweetening using MDEA
 
Hp heater ch-8.3
Hp heater ch-8.3Hp heater ch-8.3
Hp heater ch-8.3
 
Burner Design, Operation and Maintenance on Ammonia Plants
Burner Design, Operation and Maintenance on Ammonia PlantsBurner Design, Operation and Maintenance on Ammonia Plants
Burner Design, Operation and Maintenance on Ammonia Plants
 
Power Plant Major Losses
Power Plant Major LossesPower Plant Major Losses
Power Plant Major Losses
 
processoptimization-rawmillcoalmill-moduleday2-230314110558-e03314c6.pdf
processoptimization-rawmillcoalmill-moduleday2-230314110558-e03314c6.pdfprocessoptimization-rawmillcoalmill-moduleday2-230314110558-e03314c6.pdf
processoptimization-rawmillcoalmill-moduleday2-230314110558-e03314c6.pdf
 
Training material for ash handling system (fly)
Training material for ash handling system (fly)Training material for ash handling system (fly)
Training material for ash handling system (fly)
 
Fuels& Lubricants Laboratory Manual_Sept_2017
Fuels& Lubricants Laboratory Manual_Sept_2017Fuels& Lubricants Laboratory Manual_Sept_2017
Fuels& Lubricants Laboratory Manual_Sept_2017
 
Coal fired boiler presentation slideshare
Coal fired boiler presentation slideshareCoal fired boiler presentation slideshare
Coal fired boiler presentation slideshare
 
DESIGN OF AIR PRE HEATER AND ECONOMIZER
DESIGN OF AIR PRE HEATER AND ECONOMIZERDESIGN OF AIR PRE HEATER AND ECONOMIZER
DESIGN OF AIR PRE HEATER AND ECONOMIZER
 
flare system design.pdf
flare system design.pdfflare system design.pdf
flare system design.pdf
 
04 fuels & combustion calculation09
04 fuels & combustion calculation0904 fuels & combustion calculation09
04 fuels & combustion calculation09
 
Pressure Safety Valve Sizing - API 520/521/526
Pressure Safety Valve Sizing - API 520/521/526Pressure Safety Valve Sizing - API 520/521/526
Pressure Safety Valve Sizing - API 520/521/526
 
sru-presentation.pptx
sru-presentation.pptxsru-presentation.pptx
sru-presentation.pptx
 
Water Conservation - Cooling Tower Management Overview
Water Conservation - Cooling Tower Management Overview Water Conservation - Cooling Tower Management Overview
Water Conservation - Cooling Tower Management Overview
 
SULFUR RECOVERY UNIT DESIGN
SULFUR RECOVERY UNIT DESIGNSULFUR RECOVERY UNIT DESIGN
SULFUR RECOVERY UNIT DESIGN
 
ESA-CEMS Solutions_2017.pptx
ESA-CEMS Solutions_2017.pptxESA-CEMS Solutions_2017.pptx
ESA-CEMS Solutions_2017.pptx
 
Heat & Mass Balance in Cement Plant
Heat & Mass Balance in Cement PlantHeat & Mass Balance in Cement Plant
Heat & Mass Balance in Cement Plant
 
Introduction of Fired heaters
Introduction of Fired heatersIntroduction of Fired heaters
Introduction of Fired heaters
 
Accumulation and Over-pressure: difference between accumulation and overpressure
Accumulation and Over-pressure: difference between accumulation and overpressureAccumulation and Over-pressure: difference between accumulation and overpressure
Accumulation and Over-pressure: difference between accumulation and overpressure
 

Andere mochten auch

WVU Summit Address_Breton_‌final
WVU Summit Address_Breton_‌finalWVU Summit Address_Breton_‌final
WVU Summit Address_Breton_‌final
Leo Breton
 
Effects of Errors on Vehicle Emission Rates from Portable Emissions Measure...
  Effects of Errors on Vehicle Emission Rates from Portable Emissions Measure...  Effects of Errors on Vehicle Emission Rates from Portable Emissions Measure...
Effects of Errors on Vehicle Emission Rates from Portable Emissions Measure...
Gurdas Sandhu
 
Report: Mind the Gap 2015 – Closing the chasm between test and real-world car...
Report: Mind the Gap 2015 – Closing the chasm between test and real-world car...Report: Mind the Gap 2015 – Closing the chasm between test and real-world car...
Report: Mind the Gap 2015 – Closing the chasm between test and real-world car...
Nicola Barozzi 🚘✔
 
Cems brochure 2013
Cems brochure 2013Cems brochure 2013
Cems brochure 2013
a1-cbiss
 

Andere mochten auch (9)

Replacing a Stack Gas Flow Hardware Device with PEMS
Replacing a Stack Gas Flow Hardware Device with PEMSReplacing a Stack Gas Flow Hardware Device with PEMS
Replacing a Stack Gas Flow Hardware Device with PEMS
 
WVU Summit Address_Breton_‌final
WVU Summit Address_Breton_‌finalWVU Summit Address_Breton_‌final
WVU Summit Address_Breton_‌final
 
Effects of Errors on Vehicle Emission Rates from Portable Emissions Measure...
  Effects of Errors on Vehicle Emission Rates from Portable Emissions Measure...  Effects of Errors on Vehicle Emission Rates from Portable Emissions Measure...
Effects of Errors on Vehicle Emission Rates from Portable Emissions Measure...
 
Report: Mind the Gap 2015 – Closing the chasm between test and real-world car...
Report: Mind the Gap 2015 – Closing the chasm between test and real-world car...Report: Mind the Gap 2015 – Closing the chasm between test and real-world car...
Report: Mind the Gap 2015 – Closing the chasm between test and real-world car...
 
OBD I & II (On Board Diagnostic)
OBD I & II (On Board Diagnostic)OBD I & II (On Board Diagnostic)
OBD I & II (On Board Diagnostic)
 
CEMS Club Stockholm Info Session
CEMS Club Stockholm Info SessionCEMS Club Stockholm Info Session
CEMS Club Stockholm Info Session
 
On-Board Diagnostics (OBD) Program Overview
On-Board Diagnostics (OBD) Program Overview On-Board Diagnostics (OBD) Program Overview
On-Board Diagnostics (OBD) Program Overview
 
CEMS and Mössbauer Sprectroscopy
CEMS and Mössbauer SprectroscopyCEMS and Mössbauer Sprectroscopy
CEMS and Mössbauer Sprectroscopy
 
Cems brochure 2013
Cems brochure 2013Cems brochure 2013
Cems brochure 2013
 

Ähnlich wie Comparison of PEMS and CEMS

PDM IMPLIMENTATION
PDM IMPLIMENTATIONPDM IMPLIMENTATION
PDM IMPLIMENTATION
Uttam Misra
 
ovation-control-solutions-for-siemens-v-ansaldo-energia-ae-series-gas-turbine...
ovation-control-solutions-for-siemens-v-ansaldo-energia-ae-series-gas-turbine...ovation-control-solutions-for-siemens-v-ansaldo-energia-ae-series-gas-turbine...
ovation-control-solutions-for-siemens-v-ansaldo-energia-ae-series-gas-turbine...
Abhishek Sarraf
 

Ähnlich wie Comparison of PEMS and CEMS (20)

PDM IMPLIMENTATION
PDM IMPLIMENTATIONPDM IMPLIMENTATION
PDM IMPLIMENTATION
 
EnviroConnect
EnviroConnectEnviroConnect
EnviroConnect
 
Predictive maintenance
Predictive maintenancePredictive maintenance
Predictive maintenance
 
Cutler-Hammer Maintenance Program LTM 2010
Cutler-Hammer Maintenance Program LTM 2010Cutler-Hammer Maintenance Program LTM 2010
Cutler-Hammer Maintenance Program LTM 2010
 
CEMSI Cement Solutions
CEMSI Cement SolutionsCEMSI Cement Solutions
CEMSI Cement Solutions
 
5546
55465546
5546
 
White Paper - Data center solutions
White Paper - Data center solutionsWhite Paper - Data center solutions
White Paper - Data center solutions
 
All you Need to Know About Sampling and Analysis - OGSI
All you Need to Know About Sampling and Analysis - OGSIAll you Need to Know About Sampling and Analysis - OGSI
All you Need to Know About Sampling and Analysis - OGSI
 
Simple Ways to Maximize the Efficiency of Your Process Control Application Wh...
Simple Ways to Maximize the Efficiency of Your Process Control Application Wh...Simple Ways to Maximize the Efficiency of Your Process Control Application Wh...
Simple Ways to Maximize the Efficiency of Your Process Control Application Wh...
 
Warranty fraud
Warranty fraudWarranty fraud
Warranty fraud
 
Pump Monitoring System
Pump Monitoring System Pump Monitoring System
Pump Monitoring System
 
pump monitoring system
pump monitoring systempump monitoring system
pump monitoring system
 
Introduction to Reliability Centered Maintenance
Introduction to Reliability Centered MaintenanceIntroduction to Reliability Centered Maintenance
Introduction to Reliability Centered Maintenance
 
11-IAGT-202_paper
11-IAGT-202_paper11-IAGT-202_paper
11-IAGT-202_paper
 
AMO_General_2015
AMO_General_2015AMO_General_2015
AMO_General_2015
 
RC_Services Brochure
RC_Services BrochureRC_Services Brochure
RC_Services Brochure
 
ovation-control-solutions-for-siemens-v-ansaldo-energia-ae-series-gas-turbine...
ovation-control-solutions-for-siemens-v-ansaldo-energia-ae-series-gas-turbine...ovation-control-solutions-for-siemens-v-ansaldo-energia-ae-series-gas-turbine...
ovation-control-solutions-for-siemens-v-ansaldo-energia-ae-series-gas-turbine...
 
GTDS Booklet
GTDS BookletGTDS Booklet
GTDS Booklet
 
Oil production3
Oil production3Oil production3
Oil production3
 
Condition Based Asset Management R K Gupta
Condition Based Asset Management R K GuptaCondition Based Asset Management R K Gupta
Condition Based Asset Management R K Gupta
 

Mehr von CTi Controltech

Mehr von CTi Controltech (20)

Flowserve Valve, Actuation and Instrumentation Portfolio
Flowserve Valve, Actuation and Instrumentation PortfolioFlowserve Valve, Actuation and Instrumentation Portfolio
Flowserve Valve, Actuation and Instrumentation Portfolio
 
Check-All Valve Product Catalog
Check-All Valve Product CatalogCheck-All Valve Product Catalog
Check-All Valve Product Catalog
 
Sanitrx HPX & Sanitrx HPX II Rupture Discs
Sanitrx HPX & Sanitrx HPX II Rupture DiscsSanitrx HPX & Sanitrx HPX II Rupture Discs
Sanitrx HPX & Sanitrx HPX II Rupture Discs
 
Rupture Disc Burst Rating Types
Rupture Disc Burst Rating TypesRupture Disc Burst Rating Types
Rupture Disc Burst Rating Types
 
Industrial Check Valves, EPIC Series
Industrial Check Valves, EPIC SeriesIndustrial Check Valves, EPIC Series
Industrial Check Valves, EPIC Series
 
Sanitary Tank Bottom Valve
Sanitary Tank Bottom ValveSanitary Tank Bottom Valve
Sanitary Tank Bottom Valve
 
Combining Rupture Discs and Safety Relief Valves
Combining Rupture Discs and Safety Relief ValvesCombining Rupture Discs and Safety Relief Valves
Combining Rupture Discs and Safety Relief Valves
 
Flame Arrester Application Questionnaire
Flame Arrester Application QuestionnaireFlame Arrester Application Questionnaire
Flame Arrester Application Questionnaire
 
Dry Back Scotch Marine Boiler
Dry Back Scotch Marine BoilerDry Back Scotch Marine Boiler
Dry Back Scotch Marine Boiler
 
Eccentric Rotary Plug Control Valve
Eccentric Rotary Plug Control ValveEccentric Rotary Plug Control Valve
Eccentric Rotary Plug Control Valve
 
Atomac Lined Ball Valves
Atomac Lined Ball ValvesAtomac Lined Ball Valves
Atomac Lined Ball Valves
 
Groth Corporation Industrial Product Selection Guide
Groth Corporation Industrial Product Selection GuideGroth Corporation Industrial Product Selection Guide
Groth Corporation Industrial Product Selection Guide
 
Rupture Disc Products For Industrial Process Safety
Rupture Disc Products For Industrial Process SafetyRupture Disc Products For Industrial Process Safety
Rupture Disc Products For Industrial Process Safety
 
Flame control products for industrial fluid operations
Flame control products for industrial fluid operationsFlame control products for industrial fluid operations
Flame control products for industrial fluid operations
 
Rotork CMA Compact Electric Valve Actuators
Rotork CMA Compact Electric Valve ActuatorsRotork CMA Compact Electric Valve Actuators
Rotork CMA Compact Electric Valve Actuators
 
High Pressure Control Valves - Kammer
High Pressure Control Valves - KammerHigh Pressure Control Valves - Kammer
High Pressure Control Valves - Kammer
 
Electric Control Valve Actuators for Industrial Process Applications
Electric Control Valve Actuators for Industrial Process ApplicationsElectric Control Valve Actuators for Industrial Process Applications
Electric Control Valve Actuators for Industrial Process Applications
 
Electronic Line Break Protector for Fluid Systems
Electronic Line Break Protector for Fluid SystemsElectronic Line Break Protector for Fluid Systems
Electronic Line Break Protector for Fluid Systems
 
Integrated Flame Scanner For Commercial and Industrial Combustion Operations
Integrated Flame Scanner For Commercial and Industrial Combustion OperationsIntegrated Flame Scanner For Commercial and Industrial Combustion Operations
Integrated Flame Scanner For Commercial and Industrial Combustion Operations
 
Controlling Cavitation in Industrial Control Valves
Controlling Cavitation in Industrial Control ValvesControlling Cavitation in Industrial Control Valves
Controlling Cavitation in Industrial Control Valves
 

Kürzlich hochgeladen

Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Christo Ananth
 
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night StandCall Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
amitlee9823
 
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
dharasingh5698
 
AKTU Computer Networks notes --- Unit 3.pdf
AKTU Computer Networks notes ---  Unit 3.pdfAKTU Computer Networks notes ---  Unit 3.pdf
AKTU Computer Networks notes --- Unit 3.pdf
ankushspencer015
 

Kürzlich hochgeladen (20)

Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
 
Vivazz, Mieres Social Housing Design Spain
Vivazz, Mieres Social Housing Design SpainVivazz, Mieres Social Housing Design Spain
Vivazz, Mieres Social Housing Design Spain
 
Call for Papers - International Journal of Intelligent Systems and Applicatio...
Call for Papers - International Journal of Intelligent Systems and Applicatio...Call for Papers - International Journal of Intelligent Systems and Applicatio...
Call for Papers - International Journal of Intelligent Systems and Applicatio...
 
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
 
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night StandCall Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
 
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
 
chapter 5.pptx: drainage and irrigation engineering
chapter 5.pptx: drainage and irrigation engineeringchapter 5.pptx: drainage and irrigation engineering
chapter 5.pptx: drainage and irrigation engineering
 
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance BookingCall Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Walvekar Nagar Call Me 7737669865 Budget Friendly No Advance Booking
 
(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7
(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7
(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7
 
AKTU Computer Networks notes --- Unit 3.pdf
AKTU Computer Networks notes ---  Unit 3.pdfAKTU Computer Networks notes ---  Unit 3.pdf
AKTU Computer Networks notes --- Unit 3.pdf
 
Thermal Engineering Unit - I & II . ppt
Thermal Engineering  Unit - I & II . pptThermal Engineering  Unit - I & II . ppt
Thermal Engineering Unit - I & II . ppt
 
KubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghlyKubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghly
 
University management System project report..pdf
University management System project report..pdfUniversity management System project report..pdf
University management System project report..pdf
 
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdfONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
ONLINE FOOD ORDER SYSTEM PROJECT REPORT.pdf
 
Double rodded leveling 1 pdf activity 01
Double rodded leveling 1 pdf activity 01Double rodded leveling 1 pdf activity 01
Double rodded leveling 1 pdf activity 01
 
Booking open Available Pune Call Girls Pargaon 6297143586 Call Hot Indian Gi...
Booking open Available Pune Call Girls Pargaon  6297143586 Call Hot Indian Gi...Booking open Available Pune Call Girls Pargaon  6297143586 Call Hot Indian Gi...
Booking open Available Pune Call Girls Pargaon 6297143586 Call Hot Indian Gi...
 
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
 
Thermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - VThermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - V
 
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
 
data_management_and _data_science_cheat_sheet.pdf
data_management_and _data_science_cheat_sheet.pdfdata_management_and _data_science_cheat_sheet.pdf
data_management_and _data_science_cheat_sheet.pdf
 

Comparison of PEMS and CEMS

  • 1. CMCPEMSStatisticalHybrid PEMS • Lower system capital cost. • A PEMS can be configured, delivered and installed in 30- 45 days. Installation of a PEMS requires the installation of a single computer with the DAS/PEMS software installed and interfaced to the boiler control system. Typically a one day installation and start up process. • PEMS have lower startup costs, normally one day including DAS. • PEMS require less on site training. PEMS training is usually 1 to 1 1⁄2 days plus DAS training. • PEMS should require no on site emergency service. A direct modem to the system takes care of 99% of all service requirements. • PEMS do not require dual range analyzers. CMC PEMS measure the full dynamic range of emissions from a source, including start up to shut down. • PEMS do not require EPA protocol calibration gases, piping, wiring, gas regulators or software to operate the auto-calibration sequence. CMC PEMS analyzers do have auto calibration just like a CEMS. • PEMS require no air source. • PEMS have no ongoing preventative maintenance requirements as do CEMS. The only related maintenance for a PEMS is a periodic cleaning of the PEMS computer. Normal maintenance and calibration of process instruments that provide data to the PEMS is required. This maintenance should already be ongoing within a plant to maintain maximum efficiency and output; therefore, it is not considered an additional associated cost. • PEMS have higher data availability which should normally approach 100%. The PEMS does not rely on any one process input to maintain system uptime or accuracy of emissions quality. The PEMS uses numerous inputs for a robust data base. Even with a PEMS failure the data from the DCS inputs for the predictions still reside within the DCS. This data can be retrieved, calculated, and back filled by the PEMS when brought back on line. Therefore very little if any down time or missing data should ever be reported. • PEMS can display emission process and combustion efficiency outputs. • PEMS can be used to determine the source of excess emissions. Combustion input parameter(s) that are out of normal range can be identified and alarmed for immediate action and provide a trail to the diagnosis of excess emissions. • PEMS require no field hardware or additional equipment beyond the plant or process control system. In fact, the PEMS in some cases can run on a control system computer and completely eliminate the need for additional hardware. • PEMS maintenance and service is minimal. A PEMS annual service contracts after warranty period typically runs $300.00 per month, which includes maintenance, regulatory and software upgrades. PEMS maintenance and quarterly audits with onsite support for report generation run $750.00 to $1000.00 per month including emergency support with the annual service contract. • A CMC PEMS provides accuracy that is equal to that of a CEMS. PEMS inherently do not drift. PEMS rely on process inputs and instruments that typically drift no more than 0.5 to 1% per year. Typical models utilize 12 or more input parameters that are in some cases redundant. The resulting emissions prediction is resilient to input failure and drift, such that no single input parameter is critical to the accuracy of the stated emission. • The PEMS analyzer is not vulnerable to obsolescence. CMC PEMS are continually upgraded for any new regulatory changes or software upgrades through inexpensive ongoing service contracts. Typically $300.00 per month. • PEMS require no on site spare parts or consumable spare parts. TypicalCEMS CEMS • PEMS typically cost much less than CEMS (purchase price is even lower if a CEMS is on site to provide QA’d emissions data for PEMS model) • Depending on complexity and location of the CEMS, delivery is generally 12- 14 weeks and installation can take 7 to 14 days using various skilled trades (electrical, mechanical, computer) to install ports,
  • 2. probes, umbilical / trays, CEMS rack, gas cylinders, cylinder racks, gas tubing runs, drain and exhaust lines, plus interconnecting wiring. CEMS installation may cost more than the CEMS equipment. • CEMS normal start up is 2-4 days, depending on complexity. • CEMS vendors typically offer 3 day introductory system training. (Probe, sample conditioner, analyzers, controller.) In depth training is an additional 5 days. DAS training is usually another 2 days. • On site emergency service for a CEMS is inevitable. Rates run $1200.00 to $1600.00 per day plus portal to portal expenses. • CEMS may be required to have dual ranges to cover the entire range of operation. If required the system will need additional calibration gases, hardware and software. • CEMS require calibration systems and the on going purchase of EPA Protocol Gases. Cylinders of calibration gases also require safe storage and supplier documentation is necessary. No more demurrage expenses with a PEMS. • CEMS require air sources generally of instrument grade. The air is required for probe blow back and or probe dilution air. CEMS can require expansion and additional maintenance to the plant air supply in many cases. • CEMS require daily, monthly, quarterly, semi and annual maintenance. Consumable and spare parts inventories are required to maintain uptime. (Spares are generally 7-10% the cost of the system.) Specifically trained personnel are required to perform maintenance on CEMS with on call duties usually required. • CEMS typically are considered doing well if they maintain 95% uptime which is a minimum requirement. If an analyzer fails (NOx, CO or O2 etc) or a critical component fails the system is consider down and down time is logged. When a CEMS analyzer or critical component fails the system has no capability to retrieve any missing data and data substitution may be required. • CEMS do not. CEMS provide outputs of stack emissions and do not typically provide process data or source efficiency beyond unit load, fuel feed, or fuel consumption data. • CEMS do not provide any insight as to the cause of an excess emission or the ability to facilitate process control or correction of the problem.> CEMS cannot point the operator to the cause or solution of excess emissions. • CEMS can, and do, require external equipment. Cabinets with HVAC, environmentally controlled shelters or clean rooms must be provided which can take up a considerable footprint and eliminate valuable space for other process equipment. • CEMS annual service contracts typically cost $1000.00 to $2500.00 per month plus portal to portal expenses. (depending on complexity) They normally do not include emergency service, daily, weekly or monthly maintenance, such as changing gas bottles, unless specifically requested at an additional cost. Contracts that include a quarterly site visit, quarterly cylinder gas audits, and emergency support for CEMS are also priced at an additional cost. • CEMS analyzers are designed to drift no more than 1-2% daily. Long-term CEMS drift is generally experienced through contamination of sample transport and the sampling train. Total system drift is associated with the sampling probe, transport / conditioning system, sample line, temperature control, ambient conditions and specified analyzer drift. Each of these components contribute to a total system drift or inaccuracy. • CEMS are always vulnerable to analyzer obsolescence and replacement. The replacement of 2 analyzers can be equal to the purchase of a PEMS system. Two of the main suppliers of analyzers have both replaced existing analyzers with new models and cancelled support over the last ten years. • CEMS require spares and consumable spare parts to maintain performance and up time requirements and are a sizable ongoing expense.