PROCESS INSTRUMENTSTHERMOX®
ApplicationNote
www.ametekpi.com
Process Heaters, Furnaces and Fired Heaters
Improving Efficiency and Reducing NOx
PROCESS OVERVIEW
A process heater is a direct-fired heat
exchanger that uses the hot gases of
combustion to raise the temperature
of a feed flowing through coils of
tubes aligned throughout the heater.
Depending on the use, these are
also called furnaces or fired heaters.
Some heaters simply deliver the
feed at a predetermined temperature
to the next stage of the reaction
process; others perform reactions on
the feed while it travels through the
tubes.
	 Process heaters are used
throughout the hydrocarbon and
chemical processing industries in
places such as refineries, gas plants,
petrochemicals, chemicals and
synthetics, olefins, ammonia and
fertilizer plants. Some plants may
have only two or three heaters while
larger plants can have more than fifty.
	 Most of the unit operations in these
plants require fired heaters and
furnaces. These operations include:
►	Distillation
►	Fluidized Catalytic Cracking
(FCC)
►	Alkylation
►	Catalytic Reforming
►	Continuous Catalyst Regeneration
(CCR)
►	Thermal Cracking
►	Coking
►	Hydrocracking
Typical process heaters can be summarized as follows:
►	Start-Up Heater — Starts-up a process unit where it is required to heat up
a fluidized bed of catalyst before adding the charge.
►	Fired Reboiler — Provides heat input to a distillation column by heating
the column bottoms and vaporizing a portion of it. Used where heat
requirement is greater than can be obtained from steam.
►	Cracking Furnace — Converts larger molecules into smaller molecules,
usually with a catalyst (pyrolysis furnace).
►	Process Heater — Brings feed to the required temperature for the next
reaction stage.
►	Process Heater Vaporizer — Used to heat and partially vaporize a charge
prior to distillation.
►	Crude Oil Heater — Heats crude oil prior to distillation.
►	Reformer Furnace — Chemical conversion by adding steam and feed with
catalyst.
Figure 1. Process Heaters
THERMOX®
2
PROCESS HEATERS
Side view of
top section
PROCESS HEATER
Coil
Outlet
Burners
Crossover
Coil Inlet
Draft Gauge
Damper
Stack Temp
Radiant Tubes
STACK
BREECHING
CONVECTION
SECTION
SHIELD
SECTION
RADIANT
SECTION
Draft Gauge
Draft Gauge
Bridgewall
X
O2
X
O2
X O2
Figure 2. Sections of a process heater.
Many refineries use light ends (e.g.
refinery gas) from the crude units and
reformers as well as waste gases
for heater fuel. Natural gas is often
blended with waste gas and the other
off-gases as the primary fuel for heater
processes. Residual fuels such as tar,
pitch, and Bunker C (heavy oil) are also
widely used.
	 The process heater shown below
is a natural draft unit with inspiration
type burners. Combustion air flow
is regulated by positioning the stack
damper. Fuel to the burners is regulated
from exit feed temperature and firing
rate is determined by the level of
production desired.
Radiant Section
The radiant tubes, either horizontal or
vertical, are located along the walls
in the radiant section of the heater
and receive radiant heat direct from
the burners. The radiant zone with its
refractory lining is the costliest part of
the heater and 85% of the heat should
be gained there. This is also called the
firebox.
Convection Section
Rather than hit the radiant section
directly, the feed charge enters the coil
inlet in the convection section where it
is preheated before transferring to the
radiant tubes. The convection section
removes heat from the flue gas to
preheat the contents of the tubes and
significantly reduces the temperature
of the flue gas exiting the stack. Too
much heat picked up in the convection
section is a sign of too much draft.
Tube temperature is measured in both
convection and radiant sections.
Shield Section
Just below the convection section
is the shield (or shocktube) section,
containing rows of tubing which
shield the convection tubes from the
direct radiant heat. Several important
measurements are normally made
just below the shield section. The
bridgewall or breakwall temperature is
the temperature of the flue gas after the
radiant heat is removed by the radiant
tubes and before it hits the convection
section.
	 Measurement of the draft at this
point is also very important since this
determines how well the heater is
set up. Excess draft, either positive
pressure or negative pressure, can lead
to serious problems.
	 This is also the ideal place for flue
gas oxygen and ppm combustibles
measurement.
Breeching Sections and Stack
The transition from the convection
section to the stack is called the
breeching. By the time the flue gas exits
to the stack, most of the heat should
be recovered and the temperature
is much less. From a measurement
point of view, this location places fewer
demands on the analyzer but is much
less desirable for the ability to control
the process. Measurement of stack
emissions for compliance purposes is
normally made here.
THERMOX®
3
MEETING PERFORMANCE OBJECTIVES
The performance objectives of process
heaters are similar to those of other
process units:
►	Maximize heat delivery of the
process-side feed while minimizing
fuel consumption.
►	Maximize heat delivery with varying
fuel quality.
►	Minimize heater structural wear
caused by operation.
►	Minimize stack emissions (heat, CO,
NOx ).
►	Maximize safety integrity levels.
	 Proper monitoring and control brings
benefits and avoids problems in the
following areas of heater operation:
Energy Savings
All process heaters consume large
amounts of fuel to produce the
necessary heat that must be transferred
to the material brought into the furnace.
	 Energy costs represent up to 65%
of the cost of running a chemical/
petrochemical/refining complex.
Furnace and heater fuel is the largest
component of this cost. In the past,
there was little reason to seek efficiency
improvements as waste fuel was cheap
and the excess was often flared. Today
many of the refinery processes require
hydrogen, and a lot of the hydrogen-
rich off-gases, which were previously
used as heater fuel, are now needed to
meet this demand. Natural gas, which
is very expensive, is used to make up
shortfalls. Therefore the more energy
that can be squeezed from existing
plant fuels, the less supplementary
natural gas is required.
	 Correct use of gas analyzers can
conserve the amount of fuel used and
maximizes heater efficiency.
NOx Reduction
A significant fraction of NOx produced
annually can be attributed to the
chemical/ refining industry and stringent
emission limits require greater control
of NOx and other stack components.
Operating the heater at optimum
efficiency, with low excess air firing
using oxygen and ppm combustibles, is
the simplest and least expensive way to
reduce NOx emissions.
Product Quality
Temperature control of the process
tubes and reactions is critical in
reforming and cracking operations.
	 Since flaring is no longer permitted,
gases with widely varying calorific
content are now used as fuel for the
heaters. This leads to large variations
in heat delivered in the radiant section,
and therefore, to greater demands
on control of the product or feed
temperature.
Safety
No information or incorrect information
from a poorly placed analyzer can lead
to unsafe operation of heaters from air
leaks, tube leaks, and fuel or burner
problems. Purge-down and light-off
cycles require special care and warrant
methane monitoring in addition to
oxygen and ppm combustibles.
Heater and Tube Life
Incorrect operation leads to premature
failure, structural damage or tube leaks
due to flame impingement, secondary
combustion and flue gas leaks.
FACTORS AFFECTING PROCESS
HEATER OPERATION
Process heaters offer particular
challenges for measurement and
control due to:
►	High temperature in the radiant zone
where measurement is desired.
►	Multiple burners.
►	Multiple radiant zones (cells).
►	Widely varying fuel calorific value.
►	Low investment in heater
optimization.
	 A review of the factors affecting
process heater performance will be
useful . This includes draft, burner
operation, combustion efficiency and
NOx production.
THERMOX®
4
Figure 3. Correct draft
Figure 5. Excessive negative draftFigure 4. Excessive positive draft
DRAFT
For optimum operation, excess oxygen in the flue gas entering
the convection section should be minimized and there should be
a very small negative pressure at the convection section inlet.
Correct Draft
Refer to Figure 3. Stack dampers and secondary air registers
affect the draft and both adjustments are related. The hot gas
pushes so that the pressure is always greatest at the firewall. The
stack draft pulls and when correctly balanced the pressure at the
bridgewall should be close to zero or very slightly negative.
	 A process heater operating properly will also have a zero, or
slightly negative draft, at the shield section. The firebox will be
slightly positive (+0.5 to +2.0 “ water column (wc)) and the stack
will have a range of -0.5 to -1.0” wc.
	 Excessive draft, either positive pressure or negative pressure,
can lead to severe problems in the convection section.
Excessive Draft — Positive Pressure Created
In Figure 4, the air registers are wide open and the damper
mostly closed. This generates a positive pressure which forces
flue gases outward through leaks in the convection section
leading to serious structure damage, as well as heat loss.
Excessive Draft — Negative
Pressure Created
In Figure 5, the air registers are
mostly closed and the stack
damper is wide open leading
to a high negative pressure in
the convection section. Cold
ambient air is sucked in through
leaks in the convection section
leading to erroneous oxygen
readings, as well as heat loss.
In addition the excessive draft
causes tall flames which can
reach the tubes resulting in
serious damage.
Zero or Slightly
Negative Draft
0 or -0.1 to -0.5" WC
Positive Draft
+0.5 to +2.0" WC
Damper
STACK
BREECHING
CONVECTION
SECTION
SHIELD
SECTION
RADIANT
SECTION
Negative Draft
-0.5 To -1.0" WC
Damper
WIDE OPEN
-0.8" WC
Air Registers
MOSTLY CLOSED
Cold Air
Sucked In
-0.8" WC
-0.4" WC
-0.6" WC
Damper
MOSTLY CLOSED
Air Register
WIDE OPEN
-0.8" WC
-0.3" WC
+0.1" WC
-0.1" WC
Hot Flue Gas
Blown Out
THERMOX®
5
GAS
PREMIX
CHAMBER
PRIMARY
AIR REGISTER
REFRACTORY
BURNER
TIP
SECONDARY
AIR REGISTER CARBON DIOXIDE
WATER VAPOR
OXYGEN
NOx
PPM COMBUSTIBLES
(CO + H2)
NITROGEN
Figure 6. Burner with correct combustion air.
CORRECT COMBUSTION AIR
►	 Good flame length
►	 Maximum flame temperature
Combustion Efficiency and NOx Reduction
The burners on a process heater premix
the fuel with the primary air which is
aspirated into the burner by the fuel gas
flow (see Figure 6). The primary air flow
should be maximized without lifting the
flame off the burner. The pressure of the
fuel gas supply is important since low
gas pressure degrades performance.
Most of the air (as primary air) is
delivered to the burner along with the
fuel. Secondary air is introduced and
adjusted with the registers. Too much
or too little secondary air gives poor
combustion.
	 Incomplete combustion occurs when not
enough combustion air is supplied to burn all
the fuel completely. The large amount of CO
and H2
formed as a result of the incomplete
combustion makes the burner extremely
inefficient (Figure 7). This reduces the
flame temperature and might encourage the
operator to increase fuel flow thus making
matters worse. This condition may not be
noticed because leakage in the convection
section can hide insufficient air getting to
the burner. Completion of combustion in the
convection section results in heater damage.
GAS
PREMIX
CHAMBER
PRIMARY
AIR REGISTER
REFRACTORY
BURNER
TIP
SECONDARY
AIR REGISTER
Figure 7. Burner with insufficient combustion air.
INSUFFICIENT COMBUSTION AIR
►	 Long flame
►	 Cooler temperature
►	 Very little NOx
►	 Very inefficient
BURNER OPERATION
Stoichiometric Combustion
Under ideal conditions, fuel combines with exactly the right amount of oxygen to allow complete combustion. There is no
unburned fuel and no excess oxygen. This is called stoichiometric combustion. In the simple case of methane burning in air,
this can be written as
			 CH4
+ 2O2
→ CO2
+ 2H2
O
Real combustion applications are more complicated because some excess air is always needed to ensure complete
combustion of the fuel. Otherwise, significant amounts of CO are produced, reducing efficiency and increasing pollution levels.
THERMOX®
6
Normally, six to ten thermocouples
report the temperature stratification
across the radiant section and this
temperature profile of the radiant zone
is used to determine the burner air/fuel
ratio and to balance multiple burners. A
visual observation of the flame is used
to adjust the flame color and flame
height based on the fuel pressure.
After checking to see what type of
temperature pattern is generated at the
bridgewall, the burners can be adjusted
accordingly. Once the flame is set
correctly, the damper is adjusted for the
correct draft. Finally, the secondary air
supply is adjusted to give the desired
oxygen reading or O2
setpoint.
	 When set correctly, and with good
air-fuel mixing, the burner will produce
the maximum flame temperature in a
compact flame. The less secondary air
that is needed, the better the efficiency.
At optimum efficiency, the flue gas will
contain a minimum of oxygen together
with levels of combustibles (CO and
H2
) in the 100 to 200 ppm range and a
minimum of NOx.
GAS
PREMIX
CHAMBER
PRIMARY
AIR REGISTER
REFRACTORY
BURNER
TIP
SECONDARY
AIR REGISTER
Figure 8. Burner with too much combustion air.
TOO MUCH COMBUSTION AIR
►	 Short flame
►	 Cooler temperature
►	 Wasted heat
►	 Increased NOx
NOx Production
Too much combustion air reduces
flame temperature and drops efficiency
(Figure 8). In most applications this is
the biggest source of heater inefficiency
and NOx production. The high
temperature in the flame and radiant
section, together with combustion
turbulence at the burners, causes
dissociation of air molecules. The
nitrogen and oxygen atoms combine
to form nitric oxide (NO) and nitrogen
dioxide (NO2
), together known as NOx.
The more combustion air, the more
oxygen is available to produce NOx.
Conversely the less oxygen the less
chance of NOx formation (Figure 9). Figure 9. An example showing how NOx
production increase with increasing excess air.
NOx Production
0
50
100
150
200
250
300
1 2 3 4 5
% O2
PPMCO
0
20
40
60
80
100
PPMNOx
Combustibles
Nox
WHAT IS THE CORRECT O2
SETPOINT?
THERMOX®
7
WHAT IS THE CORRECT O2
SETPOINT?
The Importance of Oxygen and Combustibles
EXCESS
AIR
LOSSES
COMBUSTIBLES
LOSSES
O2 &
COMBUSTIBLES
OPTIMUM
CONTROL
POINT
300 PPM
200 PPM
100 PPM
O2
1% 4%3%2%
EFFICIENCY
COMBINED
LOSSES
O2-ONLY
OPERATING
SET POINT
Figure 10. Determining optimum O2
setpoint.
Reducing the excess air or oxygen
to the minimum safe level is the most
important step in reducing energy
consumption. There is no single O2
level that is right for all heaters. The
optimum oxygen level depends on the
load, the burner design, the type of fuel,
and the burner performance.
	 Refer to Figure 10. Reducing oxygen
while measuring the ppm combustibles
allows the correct operating point to
be determined. The actual value will
depend on the variables mentioned
previously and should be determined
for each individual analyzer placement
point. Without combustibles, it is not
possible to find the optimum setpoint,
since you cannot know when to stop
reducing the combustion air. With the
combustibles detector, the oxygen can
be reduced safely until the combustibles
starts to increase. This is the correct
value for that heater.
	 Combustibles has always been
an important part of our combustion
control strategy. Thermox used the term
“combustibles” in 1975 to refer to the
incomplete products of combustion in
flue gas, primarily carbon monoxide
and hydrogen. The detector is not
designed to measure unburned fuel
such as methane. Many operators
have previously used percent level
combustibles which is good for
detecting serious process upsets or
for precipitator protection, but has
no benefit for optimizing combustion
efficiency. For this, a reliable ppm
combustibles measurement is needed.
	 The latest generation of Thermox
ppm combustibles detectors, perfected
during 20 years of research and
development, offers excellent reliability
and performance.
	 It is often thought that the oxygen
measurement from a zirconia probe will
also indicate when there is insufficient
excess air. This is because any
combustibles present will burn on the
cell and reduce the displayed oxygen
accordingly. While this is correct,
the drop in oxygen only becomes
significant when a major upset occurs.
For example, a 2000 ppm (0.2%) level
of combustibles or CO in the flue gas
will reduce the O2
value by only 0.1%.
A drop in oxygen from 3.0 to 2.9%
will not be treated as significant by an
operator. A reading of 2000 ppm on the
combustibles detector at the same time
would certainly be noticed, and acted
upon.
Why CO Measurement is Not Sufficient
Although AMETEK does offer an
infrared CO analyzer, a CO specific
measurement is not a good choice
for process heaters for a number of
reasons.
1.	 Refinery fuel gases and other fuels
used for process heaters have a
varying H2
concentration and that
is a critical component that must
measured to achieve good heater
efficiency.
2.	 The temperature limitations on
infrared CO analyzers require
installation after the convection
section or in the stack. Improper
burning or poor fuel quality can
cause afterburning in the convection
section which leads to convection
tube bundle plugging and tube
overheating. The IR analyzer
mounted in the stack reading only
CO will not pick this up.
3.	 The response time of an extractive
CO analyzer on a sampling system
is too slow.
	 Analyzer location issues are
discussed in more detail in the following
sections.
THERMOX®
8
PRIM
ARYAIR
SECONDARY AIR REGISTERS -
MANUAL ADJUSTMENT
CHAIN OPERATED
DAMPERS
FEED
FEED
PRIM
ARY
AIR
XX
X = TYPICAL O2 INSTALLATION POINT
(ONE PER STACK) APPROX. 900°F
REFRACTORY
REFRACTORY
FUEL FUEL
FUEL
and
AIR
- IDEAL INSTALLATION POINT
APPROX. 1800°F
Figure 11. Cabin furnace with three cells.
ANALYZER CONSIDERATIONS
A process heater is a complex
combustion device with many variables
to take into consideration. Control of
the temperature of the feed inside the
tubes relies greatly on precise control of
the combustion process. Many heaters,
reformers, and furnaces have multiple
burners with two, three or more radiant
sections (or cells). Proper control
of the heater requires knowledge of
the oxygen and combustibles levels
of the flue gas as well as draft and
temperature data. However, location of
the oxygen analyzer greatly affects the
validity of the measurement for control.
It is almost impossible to operate a
heater efficiently, effectively and safely
with an oxygen measurement taken
from the convection section or, even
worse, from the stack.
Figure 11 shows a cabin furnace
with three separate radiant zones
but many configurations exist. Most
often the measurement is taken from
the convection section (position X).
How is it possible to relate an oxygen
measurement from the convection
section to what is happening in the
burner zones? Answer: It is not.
Moreover, leaks of air in the convection
section will give erroneous oxygen
readings and can mask problems in the
burner zone. Ideally, the oxygen and
combustibles should be measured in
the firebox for three reasons:
1.	 To avoid erroneous readings caused
by air leakage in the convection
zone.
2.	 Combustibles in the flue gas will
continue to burn on the hot tubes
of the convective section and will
not show the correct values at this
location.
3.	 To be able to relate to the burners
from that zone only.
It is quite common for one or more
burners to be operating with high
combustibles levels. One sure sign
of insufficient combustion air is that
increasing fuel gas flow results in a
decrease of process side temperature.
Location
THERMOX®
9
ANALYZER CONSIDERATIONS
Aspirator
Air Inlet
Oxygen Sensor
Combustibles Detector
(if supplied)
Wires
Calibration Gas Line
Aspirator
Air Line
Mounting
Plate
Temperature
Controlled
Furnace
Boiler Wall
Terminal Box
Figure 12. Close-coupled O2
/ combustibles analyzer.
Zirconium Oxide
Oxygen Cell
PPM or Percent
Combustibles Detector
Cell Housing
Convection
Loop Return
Aspirator Block
Return to
Process
Methane
Detector
Sample
Aspirator Air
Figure 13. Convection loop of
WDG-IVCM - O2
, combustibles
and methane analyzer.
Response
The response time of an analyzer is not
measured by the time it takes to react to
calibration gas, but rather by its reaction
to a process step change. Calibration
gas is forced to the analyzer under
pressure reaching the measuring cell
very quickly so that all analyzers appear
to be fast during calibration. The time it
takes for the flue gas to get to the cell,
on the other hand, depends upon the
design of the system. When comparing
analyzer response times, make sure
you are looking at “process response”,
not response to calibration gas.
	 The close-coupled extractive WDG-
IVC mounts directly to the process
flange and is heated to maintain all
sample wetted components above the
acid dewpoint. An air-operated aspirator
draws a sample into the analyzer and
returns it to the process. A portion of
this sample rises into the convection
loop past the combustibles and oxygen
cells and then back to process. This
design gives a very fast response and is
perfect for process heaters.
	 The broad definition of the word
“insitu” refers to an analyzer directly
mounted to the process flange, rather
than a remote location, with a sample
conditioning system. “Insitu” can also
refer to the distinction of whether the
zirconia cell is located inside or outside
of the flue gas duct.
	 For low temperature (1250°F/677°C
max.) locations, you can use a WDG-
Insitu, with the zirconia cell residing
in the flue gas stream. This type of
analyzer has a slower response since it
depends on diffusion of the flue gas to
the cell, rather than on induced flow.
	 A by-pass or cooling extension
tube is often used for installation of
insitu analyzers at higher temperature
locations because of the probe
temperature limit. In this configuration,
it acts as a close-coupled extractive
analyzer but with a slower response
time.
	 High temperature insitu analyzers,
heated by the process and requiring
a minimum process operating
temperature of 1200°F (648°C), are
available from some manufacturers.
These have a slightly faster response
time than standard insitus but tend to
break more easily. They also cannot
generate any process information
during heater start-up. Both process-
heated and self-heated insitus can
measure only oxygen.
Methane Detection During Start-up
As an additional precaution during the
purge-down and light-off cycle, the
methane detector will detect any natural
gas or other fuels which have leaked
into the firebox and could cause an
explosion. If the heater is started up
only rarely, the methane detector would
have limited use. When a heater or
boiler is started-up frequently, then the
methane measurement gives additional
peace of mind. Thermox offers a
combination O2
, combustibles and
methane analyzer. The methane part
is used only during the purge-down/
light-off cycle with natural gas-fired
heaters. Once lit, the oxygen and
combustibles measurements are used
for optimization.
Portable Versus Fixed (Dry Versus Wet O2
)
It is not a good idea to use the oxygen
value determined from a portable
analyzer as the set point for the fixed
oxygen analyzer. The portable, typically
fuel cell or paramagnetic based,
measures on a dry basis since the
water must be removed before the
sample is analyzed. The fixed analyzer,
normally zirconium oxide based,
measures the flue gas as is, including
the water and thus measures on a wet
basis. The dry reading is always higher
than the wet and the difference can be
significant. When measuring a flue gas
containing 20% moisture in the flue
gas and 3% O2
, the fixed analyzer will
read 3%, whereas the portable will read
3.75%. Neither is right or wrong. They
are just different ways of looking at the
same thing and in fact this principle is
used to measure flue gas moisture.
	 However, a setpoint value determined
using the protable analyzer will not be
the same as that determied using an
in-situ measurement.
THERMOX®
10
USING THERMOX OXYGEN AND PPM COMBUSTIBLES ANALYZERS FOR EFFICIENCYAND NOx REDUCTION
Figure 14. Cabin furnace showing possible placement of analyzers.
Figure 14 shows a cabin furnace with
possible locations of the analyzers.
	 The ideal locations are at the
positions marked (1). At least one
analyzer should be used for each
radiant zone. In this case the probes
are installed vertically going down into
the firebox, but it is also possible to
locate them with horizontal probes and
with the analyzer mounted lower down
on the furnace wall. Angled mounting
is sometimes necessary. Depending
upon the length of the cell, more than
one analyzer may be required to get a
representative measurement.
	 Position (2) is much less desirable
because the probe is now in the
convection section. Air ingress tends
to cause the readings to mask any
burner problems if using oxygen only,
but at least this will be picked up by
the combustibles detector (make sure
you have it!). This location gives no
information on the cells, but rather
some average of all the flue gas from
that half of the cabin. Proper control of
the furnace cannot be obtained with
this approach. Comparison between
(1) and (2) will give information on air
leakage and if analyzers already exist at
(2), they can be used for this purpose.
Typically these are low temperature
analyzers that anyway cannot be used
in position (1).
Position (3) should be used only for
stack emissions measurement and
should never be used for heater control.
	 Thermox oxygen analyzers are
designed for direct installation at the
high temperature radiant section,
typically 1500 - 2000°F (815 - 1093°C).
A wide range of options is available,
including hazardous area and floor
mount versions. All parts are easily
accessible and the analyzer can be
serviced without having to take it off the
flange.
Suggested Manual Trim of
a Fired Heater
1.	 Adjust primary air on the burner for
proper flame height and color at the
operating fuel gas pressure.
2.	 Adjust the stack damper to the
recommended - 0.1” wc draft at the
entrance to the convection section,
with secondary air registers open.
3.	 Trim the secondary air registers
to the lowest excess oxygen level
up to, but not exceeding, the ppm
combustibles operational limit as
dictated by plant personnel/ or
experience.
4.	 Readjust stack damper and
secondary air registers as necessary
to maintain convection section draft
and minimal radiant section oxygen
with a safe level of combustibles.
5.	 Set up the heater using oxygen
and combustibles. The heater is
now controlled on oxygen, and the
combustibles detector is used to
watch for process upsets and burner
performance over time. This is your
window into the process.
6.	 A 100 ppm combustibles level can
achieve maximum fuel efficiency
as well as minimizing emissions,
without sacrificing safety.
THERMOX®
11
EXPANDING HEATER CAPACITY
CONCLUSION
Not all heater situations can be
improved with the above suggestions.
Other classes of problems include:
Heat release-limited
The burner capacity limits furnace
duty. An increase of gas pressure, or
possibly increasing the burner orifice
can increase capacity. High hydrogen
content in the fuel gas can cause this.
Draft-limited
With the damper and registers wide
open, there is still insufficient air. Air
leakage into the convection section will
not permit secondary air to enter the
heater. Convection section tubes could
also be partially plugged. Increasing
secondary air opening size may remedy
the situation.
Heat absorption-limited
The product can not obtain the target
temperature. Add convective tubes,
increase product mass velocity through
tubes, adjust for dense flame.
Heater operators often feel that
they need only to maintain thermal
objectives and this can be done by
controlling the excess air using an
oxygen-only analyzer. Or if there is
no automatic trim on the heater, that
Oxygen-only is sufficient. As we have
shown, this is a misconception and
even the smallest heater absolutely
needs Oxygen and ppm combustibles.
Slugs of waste gas with poor BTU value
can hit the burners at any time and
cause major and rapid changes to the
combustion parameters.
	 Measuring oxygen and ppm
combustibles provides benefits far in
excess of the analyzer(s) installed cost.
1.	 Improves efficiency - typically 3-5%
fuel savings.
2.	 Reduces emissions - 15-20% NOx
reduction is possible.
3.	 Identify problems due to air leaks.
4.	 Identify problems due to tube leaks.
5.	 Monitor burner performance.
6.	 Maintain product quality.
7.	 Improve heater and tube life.
8.	 Critical units such as reformers
require multiple measuring points
to provide sufficient information for
proper process control.
Thermox oxygen and combustibles
analyzers can help meet heater
performance objectives with minimal
investment cost. Even older heaters
with manual secondary air adjustments
can benefit from optimization made
possible by reliable oxygen and
combustibles measurements from the
correct location.
	 All analyzers are available with a
separate control unit to be located up
to 1000 ft. (300 m) from the sensor, or
as smart sensors (IQ versions). The
smart sensors have all the electronics
built into the sensor and are accessed
via a handheld IQ Link or the LinkBus.
© 2016, by AMETEK, Inc.
All rights reserved. Printed in the U.S.A.
F-0244 Rev. 4 (0216)
One of a family of innovative process analyzer solutions from AMETEK Process Instruments.
Specifications subject to change without notice.
150 Freeport Road, Pittsburgh, PA 15238
Ph. +1-412-828-9040, Fax +1-412-826-0399
www.ametekpi.com
THERMOX®
ApplicationNote
SALES, SERVICE AND MANUFACTURING:
USA - Pennsylvania
150 Freeport Road, Pittsburgh PA 15238 • Tel: +1-412-828-9040, Fax: +1-412-826-0399
USA - Delaware
455 Corporate Blvd., Newark DE 19702 • Tel: +1-302-456-4400, Fax: +1-302-456-4444
Canada - Alberta
2876 Sunridge Way N.E., Calgary AB T1Y 7H2 • Tel: +1-403-235-8400, Fax: +1-403-248-3550
WORLDWIDE SALES AND SERVICE LOCATIONS:
USA - Houston, Texas
Tel: +1-713-466-4900, Fax: +1-713-849-1924
BRAZIL
Tel: +55 19 2107 4100
CHINA
Beijing / Tel: +86 10 8526 2111, Fax: +86 10 8526 2141
Chengdu / Tel: +86 28 8675 8111, Fax: +86 28-8675 8141
Shanghai / Tel: +86 21 6426 8111, Fax: +86 21 6426 7818
FRANCE
Tel: +33 1 30 68 89 20, Fax: +33 1 30 68 89 99
GERMANY
Tel: +49 21 59 91 36 0, Fax: +49 21 59 91 3639
INDIA
Tel: +91 80 6782 3200, Fax: +91 80 6782 3232
SINGAPORE
Tel: +65 6484 2388, Fax: +65 6481 6588
SIMPLIFYING MAINTENANCE
0.10% H2S0.50% SO20.05% H2S
4.5% H2S 0.15% H2S0.45% H2S
0.10% H2S 0.10% H2S
0.10% H2S
0.10% H2S0.50% SO2
-12.56
-4.59
0.10% H2S
Figure 15. LinkBus RIMS multiple analyzer view page
The AMETEK LinkBus RIMS
(Remote Instrument Monitoring
System) provides the customer with
plant-wide PC access to process
analyzers using the existing web
browser or through Fieldbus™,
Modbus™ protocol-based DCS
systems. The LinkBus system
is available for IQ and 2000
controller-based Thermox flue gas
analyzers, the 4000 and 880 Series
photometric analyzers and the 5000
Series moisture analyzers. Easy
access to analyzer information and
trend data allows the maintenance
department to make the most
efficient use of limited resources
and to determine process problems
versus invalid analyzer data. The
system can be configured by the
user to allow third party access
to factory personnel in order to
provide expertise to assist in
troubleshooting. The elimination of
routine maintenance visits allows
focused attention where it is most
needed. Enhanced reliability and
improved analyzer performance
both lead to tighter process control.

Weitere ähnliche Inhalte

Was ist angesagt?

Tube Wall Temperature Measurement On Steam Reformers - Best Practices
Tube Wall Temperature Measurement On Steam Reformers - Best PracticesTube Wall Temperature Measurement On Steam Reformers - Best Practices
Tube Wall Temperature Measurement On Steam Reformers - Best PracticesGerard B. Hawkins
 
An introduction to Fired Heaters.pdf
An introduction to Fired Heaters.pdfAn introduction to Fired Heaters.pdf
An introduction to Fired Heaters.pdfKarnav Rana
 
Heater operation
Heater operationHeater operation
Heater operationJOMON M.C
 
Uniform heat transfer in fired heaters
Uniform heat transfer in fired heatersUniform heat transfer in fired heaters
Uniform heat transfer in fired heatersAshutosh Garg
 
Troubleshooting in Distillation Columns
Troubleshooting in Distillation ColumnsTroubleshooting in Distillation Columns
Troubleshooting in Distillation ColumnsGerard B. Hawkins
 
Theory and Practice of Steam Reforming
Theory and Practice of Steam ReformingTheory and Practice of Steam Reforming
Theory and Practice of Steam ReformingGerard B. Hawkins
 
Fired Heater and Combustion Optimization From Yokogawa
Fired Heater and Combustion Optimization From YokogawaFired Heater and Combustion Optimization From Yokogawa
Fired Heater and Combustion Optimization From YokogawaMiller Energy, Inc.
 
Steam Reforming - A Comprehensive Review
Steam Reforming - A Comprehensive ReviewSteam Reforming - A Comprehensive Review
Steam Reforming - A Comprehensive ReviewGerard B. Hawkins
 
Steam Reformer Surveys - Techniques for Optimization of Primary Reformer Oper...
Steam Reformer Surveys - Techniques for Optimization of Primary Reformer Oper...Steam Reformer Surveys - Techniques for Optimization of Primary Reformer Oper...
Steam Reformer Surveys - Techniques for Optimization of Primary Reformer Oper...Gerard B. Hawkins
 
Steam Reforming - Types of Reformer Design
Steam Reforming - Types of Reformer DesignSteam Reforming - Types of Reformer Design
Steam Reforming - Types of Reformer DesignGerard B. Hawkins
 
Steam Reforming - Catalyst Loading
Steam Reforming - Catalyst LoadingSteam Reforming - Catalyst Loading
Steam Reforming - Catalyst LoadingGerard B. Hawkins
 
Secondary Reforming Flowsheets
Secondary Reforming FlowsheetsSecondary Reforming Flowsheets
Secondary Reforming FlowsheetsGerard B. Hawkins
 
Improve fired heaters performance and reliabilty
Improve fired heaters performance and reliabiltyImprove fired heaters performance and reliabilty
Improve fired heaters performance and reliabiltyAshutosh Garg
 
A new approach to improving heater efficiency
A new approach to improving heater efficiencyA new approach to improving heater efficiency
A new approach to improving heater efficiencyAshutosh Garg
 
Gas Flare Stack Process
Gas Flare Stack ProcessGas Flare Stack Process
Gas Flare Stack ProcessShad Ibrahim
 
Steam Reforming - Tube Design
Steam Reforming - Tube DesignSteam Reforming - Tube Design
Steam Reforming - Tube DesignGerard B. Hawkins
 
Benfield system
Benfield systemBenfield system
Benfield systemPrem Baboo
 

Was ist angesagt? (20)

Tube Wall Temperature Measurement On Steam Reformers - Best Practices
Tube Wall Temperature Measurement On Steam Reformers - Best PracticesTube Wall Temperature Measurement On Steam Reformers - Best Practices
Tube Wall Temperature Measurement On Steam Reformers - Best Practices
 
An introduction to Fired Heaters.pdf
An introduction to Fired Heaters.pdfAn introduction to Fired Heaters.pdf
An introduction to Fired Heaters.pdf
 
Heater operation
Heater operationHeater operation
Heater operation
 
Uniform heat transfer in fired heaters
Uniform heat transfer in fired heatersUniform heat transfer in fired heaters
Uniform heat transfer in fired heaters
 
Excess air
Excess airExcess air
Excess air
 
Troubleshooting in Distillation Columns
Troubleshooting in Distillation ColumnsTroubleshooting in Distillation Columns
Troubleshooting in Distillation Columns
 
Theory and Practice of Steam Reforming
Theory and Practice of Steam ReformingTheory and Practice of Steam Reforming
Theory and Practice of Steam Reforming
 
Fired Heater and Combustion Optimization From Yokogawa
Fired Heater and Combustion Optimization From YokogawaFired Heater and Combustion Optimization From Yokogawa
Fired Heater and Combustion Optimization From Yokogawa
 
cdu and vdu unit
cdu and vdu unitcdu and vdu unit
cdu and vdu unit
 
Steam Reforming - A Comprehensive Review
Steam Reforming - A Comprehensive ReviewSteam Reforming - A Comprehensive Review
Steam Reforming - A Comprehensive Review
 
Steam Reformer Surveys - Techniques for Optimization of Primary Reformer Oper...
Steam Reformer Surveys - Techniques for Optimization of Primary Reformer Oper...Steam Reformer Surveys - Techniques for Optimization of Primary Reformer Oper...
Steam Reformer Surveys - Techniques for Optimization of Primary Reformer Oper...
 
Steam Reforming - Types of Reformer Design
Steam Reforming - Types of Reformer DesignSteam Reforming - Types of Reformer Design
Steam Reforming - Types of Reformer Design
 
Steam Reforming - Catalyst Loading
Steam Reforming - Catalyst LoadingSteam Reforming - Catalyst Loading
Steam Reforming - Catalyst Loading
 
Secondary Reforming Flowsheets
Secondary Reforming FlowsheetsSecondary Reforming Flowsheets
Secondary Reforming Flowsheets
 
Ammonia CO2 Removal Systems
Ammonia CO2 Removal SystemsAmmonia CO2 Removal Systems
Ammonia CO2 Removal Systems
 
Improve fired heaters performance and reliabilty
Improve fired heaters performance and reliabiltyImprove fired heaters performance and reliabilty
Improve fired heaters performance and reliabilty
 
A new approach to improving heater efficiency
A new approach to improving heater efficiencyA new approach to improving heater efficiency
A new approach to improving heater efficiency
 
Gas Flare Stack Process
Gas Flare Stack ProcessGas Flare Stack Process
Gas Flare Stack Process
 
Steam Reforming - Tube Design
Steam Reforming - Tube DesignSteam Reforming - Tube Design
Steam Reforming - Tube Design
 
Benfield system
Benfield systemBenfield system
Benfield system
 

Andere mochten auch

Fired heater simulation
Fired heater simulationFired heater simulation
Fired heater simulationHaDeGo
 
Fired Heater Efficiency Guide
Fired Heater Efficiency GuideFired Heater Efficiency Guide
Fired Heater Efficiency Guidejustinforth
 
furnace design
 furnace design  furnace design
furnace design Atal Khan
 
Furnaces and fired heaters
Furnaces and fired heatersFurnaces and fired heaters
Furnaces and fired heatersHiren Shah
 
Introduction to furnace and its types
Introduction to furnace and its typesIntroduction to furnace and its types
Introduction to furnace and its typessteadfast123
 
Esteem - the fired heater company
Esteem - the fired heater companyEsteem - the fired heater company
Esteem - the fired heater companyTanveer Singh
 
Furnace Improvements Sales Presentation
Furnace Improvements Sales PresentationFurnace Improvements Sales Presentation
Furnace Improvements Sales PresentationJonathan Morales
 
Burner Design, Operation and Maintenance on Ammonia Plants
Burner Design, Operation and Maintenance on Ammonia PlantsBurner Design, Operation and Maintenance on Ammonia Plants
Burner Design, Operation and Maintenance on Ammonia PlantsGerard B. Hawkins
 
Oil refinery processes 14 th jan
Oil refinery processes 14 th janOil refinery processes 14 th jan
Oil refinery processes 14 th janProbodh Mallick
 
kamal cert 3 in process plant operations
kamal cert 3 in process plant operationskamal cert 3 in process plant operations
kamal cert 3 in process plant operationsKamal Singh
 
Ingerem india - operating manual presentation
Ingerem india -  operating manual presentation Ingerem india -  operating manual presentation
Ingerem india - operating manual presentation Vidhya Biju
 
Natalie Lewes Short Course Process Plant Operations Cranfield University 2001
Natalie Lewes Short Course Process Plant Operations Cranfield University 2001Natalie Lewes Short Course Process Plant Operations Cranfield University 2001
Natalie Lewes Short Course Process Plant Operations Cranfield University 2001Natalie Lewes
 
Chlor alkali plant Control room operator & Plant Operations
Chlor alkali plant Control room operator & Plant OperationsChlor alkali plant Control room operator & Plant Operations
Chlor alkali plant Control room operator & Plant OperationsSURESHKUMAR MUTHURAMALINGAM
 
Heat capacity and transfer of heat
Heat capacity and transfer of heatHeat capacity and transfer of heat
Heat capacity and transfer of heatAbdul Wadood Khan
 
Modular fired heaters - A presentation by Esteem Projects at Refining India ...
Modular fired heaters -  A presentation by Esteem Projects at Refining India ...Modular fired heaters -  A presentation by Esteem Projects at Refining India ...
Modular fired heaters - A presentation by Esteem Projects at Refining India ...Tanveer Singh
 
Improve shale oil crude heater performance summary slideshare
Improve shale oil crude heater performance summary slideshareImprove shale oil crude heater performance summary slideshare
Improve shale oil crude heater performance summary slideshareAshutosh Garg
 

Andere mochten auch (19)

Fired heater simulation
Fired heater simulationFired heater simulation
Fired heater simulation
 
Fired Heater Efficiency Guide
Fired Heater Efficiency GuideFired Heater Efficiency Guide
Fired Heater Efficiency Guide
 
furnace design
 furnace design  furnace design
furnace design
 
Furnaces
FurnacesFurnaces
Furnaces
 
Furnaces and fired heaters
Furnaces and fired heatersFurnaces and fired heaters
Furnaces and fired heaters
 
Introduction to furnace and its types
Introduction to furnace and its typesIntroduction to furnace and its types
Introduction to furnace and its types
 
Esteem - the fired heater company
Esteem - the fired heater companyEsteem - the fired heater company
Esteem - the fired heater company
 
Furnace Improvements Sales Presentation
Furnace Improvements Sales PresentationFurnace Improvements Sales Presentation
Furnace Improvements Sales Presentation
 
Industrial Furnace Types
Industrial Furnace TypesIndustrial Furnace Types
Industrial Furnace Types
 
Burner Design, Operation and Maintenance on Ammonia Plants
Burner Design, Operation and Maintenance on Ammonia PlantsBurner Design, Operation and Maintenance on Ammonia Plants
Burner Design, Operation and Maintenance on Ammonia Plants
 
Oil refinery processes 14 th jan
Oil refinery processes 14 th janOil refinery processes 14 th jan
Oil refinery processes 14 th jan
 
Electric Process Heaters
Electric Process HeatersElectric Process Heaters
Electric Process Heaters
 
kamal cert 3 in process plant operations
kamal cert 3 in process plant operationskamal cert 3 in process plant operations
kamal cert 3 in process plant operations
 
Ingerem india - operating manual presentation
Ingerem india -  operating manual presentation Ingerem india -  operating manual presentation
Ingerem india - operating manual presentation
 
Natalie Lewes Short Course Process Plant Operations Cranfield University 2001
Natalie Lewes Short Course Process Plant Operations Cranfield University 2001Natalie Lewes Short Course Process Plant Operations Cranfield University 2001
Natalie Lewes Short Course Process Plant Operations Cranfield University 2001
 
Chlor alkali plant Control room operator & Plant Operations
Chlor alkali plant Control room operator & Plant OperationsChlor alkali plant Control room operator & Plant Operations
Chlor alkali plant Control room operator & Plant Operations
 
Heat capacity and transfer of heat
Heat capacity and transfer of heatHeat capacity and transfer of heat
Heat capacity and transfer of heat
 
Modular fired heaters - A presentation by Esteem Projects at Refining India ...
Modular fired heaters -  A presentation by Esteem Projects at Refining India ...Modular fired heaters -  A presentation by Esteem Projects at Refining India ...
Modular fired heaters - A presentation by Esteem Projects at Refining India ...
 
Improve shale oil crude heater performance summary slideshare
Improve shale oil crude heater performance summary slideshareImprove shale oil crude heater performance summary slideshare
Improve shale oil crude heater performance summary slideshare
 

Ähnlich wie Process Heaters, Furnaces and Fired Heaters: Improving Efficiency and Reducing NOx

nitrogen_syngas_article_controlling_the_stresses_of-the_primary_reformer_may_...
nitrogen_syngas_article_controlling_the_stresses_of-the_primary_reformer_may_...nitrogen_syngas_article_controlling_the_stresses_of-the_primary_reformer_may_...
nitrogen_syngas_article_controlling_the_stresses_of-the_primary_reformer_may_...Shubham Mishra
 
Key lessons to optimise ammonia plant
Key lessons to optimise ammonia plantKey lessons to optimise ammonia plant
Key lessons to optimise ammonia plantPRAVEEN SINGH
 
Soot Blowing Optimization- Field Experience
Soot Blowing Optimization- Field ExperienceSoot Blowing Optimization- Field Experience
Soot Blowing Optimization- Field ExperiencePooja Agarwal
 
28. WASTE HEAT RECOVERY.ppt
28. WASTE HEAT RECOVERY.ppt28. WASTE HEAT RECOVERY.ppt
28. WASTE HEAT RECOVERY.pptRENERGISTICS
 
firedheateroperationandtroubleshooting-220910180339-c7fe10c5 (1).pptx
firedheateroperationandtroubleshooting-220910180339-c7fe10c5 (1).pptxfiredheateroperationandtroubleshooting-220910180339-c7fe10c5 (1).pptx
firedheateroperationandtroubleshooting-220910180339-c7fe10c5 (1).pptxFahadReda2
 
Ammonia plant efficiency
Ammonia plant efficiencyAmmonia plant efficiency
Ammonia plant efficiencyHimanshu Sharma
 
Welcome to International Journal of Engineering Research and Development (IJERD)
Welcome to International Journal of Engineering Research and Development (IJERD)Welcome to International Journal of Engineering Research and Development (IJERD)
Welcome to International Journal of Engineering Research and Development (IJERD)IJERD Editor
 
Minimising emissions, maximising alternative fuels
Minimising emissions, maximising alternative fuelsMinimising emissions, maximising alternative fuels
Minimising emissions, maximising alternative fuelsA TEC Group
 
Aph operation and emergency handling
Aph operation and emergency handlingAph operation and emergency handling
Aph operation and emergency handlingParag Agrawal
 
Feedwater heaters in thermal power plants
Feedwater heaters in thermal power plantsFeedwater heaters in thermal power plants
Feedwater heaters in thermal power plantsSHIVAJI CHOUDHURY
 
Agc wp-dissolved gases in transformer insulation fluids
Agc wp-dissolved gases in transformer insulation fluidsAgc wp-dissolved gases in transformer insulation fluids
Agc wp-dissolved gases in transformer insulation fluidsAGC International, LLC
 
Dual chamber vacuum furnace for Low Pressure Carburizing (LPC) and High Press...
Dual chamber vacuum furnace for Low Pressure Carburizing (LPC) and High Press...Dual chamber vacuum furnace for Low Pressure Carburizing (LPC) and High Press...
Dual chamber vacuum furnace for Low Pressure Carburizing (LPC) and High Press...ALD Vacuum Systems Inc.
 
New rich text document
New rich text documentNew rich text document
New rich text documentmanojg1990
 
Good heater specifications pay off
Good heater specifications pay off Good heater specifications pay off
Good heater specifications pay off Ashutosh Garg
 
waste heat recovery
waste heat recovery waste heat recovery
waste heat recovery Sagar Joshi
 
Combustion chambers-and-performance
Combustion chambers-and-performanceCombustion chambers-and-performance
Combustion chambers-and-performancemanojg1990
 
Boiler efficiency & safety
Boiler efficiency & safetyBoiler efficiency & safety
Boiler efficiency & safetyRakeshBhowmick1
 

Ähnlich wie Process Heaters, Furnaces and Fired Heaters: Improving Efficiency and Reducing NOx (20)

nitrogen_syngas_article_controlling_the_stresses_of-the_primary_reformer_may_...
nitrogen_syngas_article_controlling_the_stresses_of-the_primary_reformer_may_...nitrogen_syngas_article_controlling_the_stresses_of-the_primary_reformer_may_...
nitrogen_syngas_article_controlling_the_stresses_of-the_primary_reformer_may_...
 
Key lessons to optimise ammonia plant
Key lessons to optimise ammonia plantKey lessons to optimise ammonia plant
Key lessons to optimise ammonia plant
 
Soot Blowing Optimization- Field Experience
Soot Blowing Optimization- Field ExperienceSoot Blowing Optimization- Field Experience
Soot Blowing Optimization- Field Experience
 
28. WASTE HEAT RECOVERY.ppt
28. WASTE HEAT RECOVERY.ppt28. WASTE HEAT RECOVERY.ppt
28. WASTE HEAT RECOVERY.ppt
 
firedheateroperationandtroubleshooting-220910180339-c7fe10c5 (1).pptx
firedheateroperationandtroubleshooting-220910180339-c7fe10c5 (1).pptxfiredheateroperationandtroubleshooting-220910180339-c7fe10c5 (1).pptx
firedheateroperationandtroubleshooting-220910180339-c7fe10c5 (1).pptx
 
Ammonia plant efficiency
Ammonia plant efficiencyAmmonia plant efficiency
Ammonia plant efficiency
 
lecture 4.pdf
lecture 4.pdflecture 4.pdf
lecture 4.pdf
 
Welcome to International Journal of Engineering Research and Development (IJERD)
Welcome to International Journal of Engineering Research and Development (IJERD)Welcome to International Journal of Engineering Research and Development (IJERD)
Welcome to International Journal of Engineering Research and Development (IJERD)
 
Minimising emissions, maximising alternative fuels
Minimising emissions, maximising alternative fuelsMinimising emissions, maximising alternative fuels
Minimising emissions, maximising alternative fuels
 
Aph operation and emergency handling
Aph operation and emergency handlingAph operation and emergency handling
Aph operation and emergency handling
 
Feedwater heaters in thermal power plants
Feedwater heaters in thermal power plantsFeedwater heaters in thermal power plants
Feedwater heaters in thermal power plants
 
Agc wp-dissolved gases in transformer insulation fluids
Agc wp-dissolved gases in transformer insulation fluidsAgc wp-dissolved gases in transformer insulation fluids
Agc wp-dissolved gases in transformer insulation fluids
 
Dual chamber vacuum furnace for Low Pressure Carburizing (LPC) and High Press...
Dual chamber vacuum furnace for Low Pressure Carburizing (LPC) and High Press...Dual chamber vacuum furnace for Low Pressure Carburizing (LPC) and High Press...
Dual chamber vacuum furnace for Low Pressure Carburizing (LPC) and High Press...
 
Tez
TezTez
Tez
 
New rich text document
New rich text documentNew rich text document
New rich text document
 
Good heater specifications pay off
Good heater specifications pay off Good heater specifications pay off
Good heater specifications pay off
 
waste heat recovery
waste heat recovery waste heat recovery
waste heat recovery
 
Combustion chambers-and-performance
Combustion chambers-and-performanceCombustion chambers-and-performance
Combustion chambers-and-performance
 
Boiler efficiency & safety
Boiler efficiency & safetyBoiler efficiency & safety
Boiler efficiency & safety
 
Turbin gas
Turbin gas Turbin gas
Turbin gas
 

Mehr von Belilove Company-Engineers

General Specification for Thermofoil Heater, All-Polyimide, Space Applications
General Specification for Thermofoil Heater, All-Polyimide, Space ApplicationsGeneral Specification for Thermofoil Heater, All-Polyimide, Space Applications
General Specification for Thermofoil Heater, All-Polyimide, Space ApplicationsBelilove Company-Engineers
 
BCE Flanged, Replaceable, Multi-Thermocouple Feedthroughs
BCE Flanged, Replaceable, Multi-Thermocouple FeedthroughsBCE Flanged, Replaceable, Multi-Thermocouple Feedthroughs
BCE Flanged, Replaceable, Multi-Thermocouple FeedthroughsBelilove Company-Engineers
 
NASA Preferred Reliability Practices Vacuum Seals Design Criteria
NASA Preferred Reliability Practices Vacuum Seals Design CriteriaNASA Preferred Reliability Practices Vacuum Seals Design Criteria
NASA Preferred Reliability Practices Vacuum Seals Design CriteriaBelilove Company-Engineers
 
Application of alarm annunciator as cyber security layer
Application of alarm annunciator as cyber security layerApplication of alarm annunciator as cyber security layer
Application of alarm annunciator as cyber security layerBelilove Company-Engineers
 
Selecting the Right Magnetic Level Indicator (MLI)
Selecting the Right Magnetic Level Indicator (MLI)Selecting the Right Magnetic Level Indicator (MLI)
Selecting the Right Magnetic Level Indicator (MLI)Belilove Company-Engineers
 
Installation Operation Manual for Brooks GF100 Series
Installation Operation Manual for Brooks GF100 SeriesInstallation Operation Manual for Brooks GF100 Series
Installation Operation Manual for Brooks GF100 SeriesBelilove Company-Engineers
 
Comparing Industrial Level Displacer Transmitter Technologies
Comparing Industrial Level Displacer Transmitter TechnologiesComparing Industrial Level Displacer Transmitter Technologies
Comparing Industrial Level Displacer Transmitter TechnologiesBelilove Company-Engineers
 
Ammonium & Nitrate Analyzers for Water Treatment
Ammonium & Nitrate Analyzers for Water TreatmentAmmonium & Nitrate Analyzers for Water Treatment
Ammonium & Nitrate Analyzers for Water TreatmentBelilove Company-Engineers
 
Optimizing the Steam Generation Cycle and Condensate Recovery Process
Optimizing the Steam Generation Cycle and Condensate Recovery ProcessOptimizing the Steam Generation Cycle and Condensate Recovery Process
Optimizing the Steam Generation Cycle and Condensate Recovery ProcessBelilove Company-Engineers
 
Control Valves for the Power Generation Industry" A Product and Applications ...
Control Valves for the Power Generation Industry" A Product and Applications ...Control Valves for the Power Generation Industry" A Product and Applications ...
Control Valves for the Power Generation Industry" A Product and Applications ...Belilove Company-Engineers
 
Combustion Analyzer to Add Extra Layer of Safety to Burner Management System
Combustion Analyzer to Add Extra Layer of Safety to Burner Management SystemCombustion Analyzer to Add Extra Layer of Safety to Burner Management System
Combustion Analyzer to Add Extra Layer of Safety to Burner Management SystemBelilove Company-Engineers
 
Applying Thin Film Coatings in Medical Devices
Applying Thin Film Coatings in Medical DevicesApplying Thin Film Coatings in Medical Devices
Applying Thin Film Coatings in Medical DevicesBelilove Company-Engineers
 
Electric Heating Element Technical Reference Guide
Electric Heating Element Technical Reference GuideElectric Heating Element Technical Reference Guide
Electric Heating Element Technical Reference GuideBelilove Company-Engineers
 

Mehr von Belilove Company-Engineers (20)

BCE’s Vacuum Ring Heater
BCE’s Vacuum Ring HeaterBCE’s Vacuum Ring Heater
BCE’s Vacuum Ring Heater
 
BCE SUPERCIRC Heater
BCE SUPERCIRC HeaterBCE SUPERCIRC Heater
BCE SUPERCIRC Heater
 
General Specification for Thermofoil Heater, All-Polyimide, Space Applications
General Specification for Thermofoil Heater, All-Polyimide, Space ApplicationsGeneral Specification for Thermofoil Heater, All-Polyimide, Space Applications
General Specification for Thermofoil Heater, All-Polyimide, Space Applications
 
BCE Flanged, Replaceable, Multi-Thermocouple Feedthroughs
BCE Flanged, Replaceable, Multi-Thermocouple FeedthroughsBCE Flanged, Replaceable, Multi-Thermocouple Feedthroughs
BCE Flanged, Replaceable, Multi-Thermocouple Feedthroughs
 
NASA Preferred Reliability Practices Vacuum Seals Design Criteria
NASA Preferred Reliability Practices Vacuum Seals Design CriteriaNASA Preferred Reliability Practices Vacuum Seals Design Criteria
NASA Preferred Reliability Practices Vacuum Seals Design Criteria
 
Heaters for process air and gases
Heaters for process air and gasesHeaters for process air and gases
Heaters for process air and gases
 
Magnetic Level Indicator Selection Guide
Magnetic Level Indicator Selection GuideMagnetic Level Indicator Selection Guide
Magnetic Level Indicator Selection Guide
 
Liquid Turbine Flow Meter
Liquid Turbine Flow MeterLiquid Turbine Flow Meter
Liquid Turbine Flow Meter
 
Application of alarm annunciator as cyber security layer
Application of alarm annunciator as cyber security layerApplication of alarm annunciator as cyber security layer
Application of alarm annunciator as cyber security layer
 
Selecting the Right Magnetic Level Indicator (MLI)
Selecting the Right Magnetic Level Indicator (MLI)Selecting the Right Magnetic Level Indicator (MLI)
Selecting the Right Magnetic Level Indicator (MLI)
 
Installation Operation Manual for Brooks GF100 Series
Installation Operation Manual for Brooks GF100 SeriesInstallation Operation Manual for Brooks GF100 Series
Installation Operation Manual for Brooks GF100 Series
 
Comparing Industrial Level Displacer Transmitter Technologies
Comparing Industrial Level Displacer Transmitter TechnologiesComparing Industrial Level Displacer Transmitter Technologies
Comparing Industrial Level Displacer Transmitter Technologies
 
Ammonium & Nitrate Analyzers for Water Treatment
Ammonium & Nitrate Analyzers for Water TreatmentAmmonium & Nitrate Analyzers for Water Treatment
Ammonium & Nitrate Analyzers for Water Treatment
 
Optimizing the Steam Generation Cycle and Condensate Recovery Process
Optimizing the Steam Generation Cycle and Condensate Recovery ProcessOptimizing the Steam Generation Cycle and Condensate Recovery Process
Optimizing the Steam Generation Cycle and Condensate Recovery Process
 
Control Valves for the Power Generation Industry" A Product and Applications ...
Control Valves for the Power Generation Industry" A Product and Applications ...Control Valves for the Power Generation Industry" A Product and Applications ...
Control Valves for the Power Generation Industry" A Product and Applications ...
 
Combustion Analyzer to Add Extra Layer of Safety to Burner Management System
Combustion Analyzer to Add Extra Layer of Safety to Burner Management SystemCombustion Analyzer to Add Extra Layer of Safety to Burner Management System
Combustion Analyzer to Add Extra Layer of Safety to Burner Management System
 
Applying Thin Film Coatings in Medical Devices
Applying Thin Film Coatings in Medical DevicesApplying Thin Film Coatings in Medical Devices
Applying Thin Film Coatings in Medical Devices
 
Intrinsic Safety Explained
Intrinsic Safety ExplainedIntrinsic Safety Explained
Intrinsic Safety Explained
 
BCE Custom Vacuum Feedthroughs
BCE Custom Vacuum FeedthroughsBCE Custom Vacuum Feedthroughs
BCE Custom Vacuum Feedthroughs
 
Electric Heating Element Technical Reference Guide
Electric Heating Element Technical Reference GuideElectric Heating Element Technical Reference Guide
Electric Heating Element Technical Reference Guide
 

Kürzlich hochgeladen

VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Bookingdharasingh5698
 
University management System project report..pdf
University management System project report..pdfUniversity management System project report..pdf
University management System project report..pdfKamal Acharya
 
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...ranjana rawat
 
data_management_and _data_science_cheat_sheet.pdf
data_management_and _data_science_cheat_sheet.pdfdata_management_and _data_science_cheat_sheet.pdf
data_management_and _data_science_cheat_sheet.pdfJiananWang21
 
Online banking management system project.pdf
Online banking management system project.pdfOnline banking management system project.pdf
Online banking management system project.pdfKamal Acharya
 
chapter 5.pptx: drainage and irrigation engineering
chapter 5.pptx: drainage and irrigation engineeringchapter 5.pptx: drainage and irrigation engineering
chapter 5.pptx: drainage and irrigation engineeringmulugeta48
 
Thermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.pptThermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.pptDineshKumar4165
 
UNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its PerformanceUNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its Performancesivaprakash250
 
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756dollysharma2066
 
Call for Papers - International Journal of Intelligent Systems and Applicatio...
Call for Papers - International Journal of Intelligent Systems and Applicatio...Call for Papers - International Journal of Intelligent Systems and Applicatio...
Call for Papers - International Journal of Intelligent Systems and Applicatio...Christo Ananth
 
Double rodded leveling 1 pdf activity 01
Double rodded leveling 1 pdf activity 01Double rodded leveling 1 pdf activity 01
Double rodded leveling 1 pdf activity 01KreezheaRecto
 
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Bookingdharasingh5698
 
Call Girls Wakad Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Wakad Call Me 7737669865 Budget Friendly No Advance BookingCall Girls Wakad Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Wakad Call Me 7737669865 Budget Friendly No Advance Bookingroncy bisnoi
 
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXssuser89054b
 
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete RecordCCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete RecordAsst.prof M.Gokilavani
 
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...ranjana rawat
 
Bhosari ( Call Girls ) Pune 6297143586 Hot Model With Sexy Bhabi Ready For ...
Bhosari ( Call Girls ) Pune  6297143586  Hot Model With Sexy Bhabi Ready For ...Bhosari ( Call Girls ) Pune  6297143586  Hot Model With Sexy Bhabi Ready For ...
Bhosari ( Call Girls ) Pune 6297143586 Hot Model With Sexy Bhabi Ready For ...tanu pandey
 

Kürzlich hochgeladen (20)

VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
 
University management System project report..pdf
University management System project report..pdfUniversity management System project report..pdf
University management System project report..pdf
 
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
 
data_management_and _data_science_cheat_sheet.pdf
data_management_and _data_science_cheat_sheet.pdfdata_management_and _data_science_cheat_sheet.pdf
data_management_and _data_science_cheat_sheet.pdf
 
Roadmap to Membership of RICS - Pathways and Routes
Roadmap to Membership of RICS - Pathways and RoutesRoadmap to Membership of RICS - Pathways and Routes
Roadmap to Membership of RICS - Pathways and Routes
 
Online banking management system project.pdf
Online banking management system project.pdfOnline banking management system project.pdf
Online banking management system project.pdf
 
chapter 5.pptx: drainage and irrigation engineering
chapter 5.pptx: drainage and irrigation engineeringchapter 5.pptx: drainage and irrigation engineering
chapter 5.pptx: drainage and irrigation engineering
 
Thermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.pptThermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.ppt
 
UNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its PerformanceUNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its Performance
 
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
 
NFPA 5000 2024 standard .
NFPA 5000 2024 standard                                  .NFPA 5000 2024 standard                                  .
NFPA 5000 2024 standard .
 
Call for Papers - International Journal of Intelligent Systems and Applicatio...
Call for Papers - International Journal of Intelligent Systems and Applicatio...Call for Papers - International Journal of Intelligent Systems and Applicatio...
Call for Papers - International Journal of Intelligent Systems and Applicatio...
 
Double rodded leveling 1 pdf activity 01
Double rodded leveling 1 pdf activity 01Double rodded leveling 1 pdf activity 01
Double rodded leveling 1 pdf activity 01
 
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
 
Call Girls Wakad Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Wakad Call Me 7737669865 Budget Friendly No Advance BookingCall Girls Wakad Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Wakad Call Me 7737669865 Budget Friendly No Advance Booking
 
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
 
(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7
(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7
(INDIRA) Call Girl Meerut Call Now 8617697112 Meerut Escorts 24x7
 
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete RecordCCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
 
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
 
Bhosari ( Call Girls ) Pune 6297143586 Hot Model With Sexy Bhabi Ready For ...
Bhosari ( Call Girls ) Pune  6297143586  Hot Model With Sexy Bhabi Ready For ...Bhosari ( Call Girls ) Pune  6297143586  Hot Model With Sexy Bhabi Ready For ...
Bhosari ( Call Girls ) Pune 6297143586 Hot Model With Sexy Bhabi Ready For ...
 

Process Heaters, Furnaces and Fired Heaters: Improving Efficiency and Reducing NOx

  • 1. PROCESS INSTRUMENTSTHERMOX® ApplicationNote www.ametekpi.com Process Heaters, Furnaces and Fired Heaters Improving Efficiency and Reducing NOx PROCESS OVERVIEW A process heater is a direct-fired heat exchanger that uses the hot gases of combustion to raise the temperature of a feed flowing through coils of tubes aligned throughout the heater. Depending on the use, these are also called furnaces or fired heaters. Some heaters simply deliver the feed at a predetermined temperature to the next stage of the reaction process; others perform reactions on the feed while it travels through the tubes. Process heaters are used throughout the hydrocarbon and chemical processing industries in places such as refineries, gas plants, petrochemicals, chemicals and synthetics, olefins, ammonia and fertilizer plants. Some plants may have only two or three heaters while larger plants can have more than fifty. Most of the unit operations in these plants require fired heaters and furnaces. These operations include: ► Distillation ► Fluidized Catalytic Cracking (FCC) ► Alkylation ► Catalytic Reforming ► Continuous Catalyst Regeneration (CCR) ► Thermal Cracking ► Coking ► Hydrocracking Typical process heaters can be summarized as follows: ► Start-Up Heater — Starts-up a process unit where it is required to heat up a fluidized bed of catalyst before adding the charge. ► Fired Reboiler — Provides heat input to a distillation column by heating the column bottoms and vaporizing a portion of it. Used where heat requirement is greater than can be obtained from steam. ► Cracking Furnace — Converts larger molecules into smaller molecules, usually with a catalyst (pyrolysis furnace). ► Process Heater — Brings feed to the required temperature for the next reaction stage. ► Process Heater Vaporizer — Used to heat and partially vaporize a charge prior to distillation. ► Crude Oil Heater — Heats crude oil prior to distillation. ► Reformer Furnace — Chemical conversion by adding steam and feed with catalyst. Figure 1. Process Heaters
  • 2. THERMOX® 2 PROCESS HEATERS Side view of top section PROCESS HEATER Coil Outlet Burners Crossover Coil Inlet Draft Gauge Damper Stack Temp Radiant Tubes STACK BREECHING CONVECTION SECTION SHIELD SECTION RADIANT SECTION Draft Gauge Draft Gauge Bridgewall X O2 X O2 X O2 Figure 2. Sections of a process heater. Many refineries use light ends (e.g. refinery gas) from the crude units and reformers as well as waste gases for heater fuel. Natural gas is often blended with waste gas and the other off-gases as the primary fuel for heater processes. Residual fuels such as tar, pitch, and Bunker C (heavy oil) are also widely used. The process heater shown below is a natural draft unit with inspiration type burners. Combustion air flow is regulated by positioning the stack damper. Fuel to the burners is regulated from exit feed temperature and firing rate is determined by the level of production desired. Radiant Section The radiant tubes, either horizontal or vertical, are located along the walls in the radiant section of the heater and receive radiant heat direct from the burners. The radiant zone with its refractory lining is the costliest part of the heater and 85% of the heat should be gained there. This is also called the firebox. Convection Section Rather than hit the radiant section directly, the feed charge enters the coil inlet in the convection section where it is preheated before transferring to the radiant tubes. The convection section removes heat from the flue gas to preheat the contents of the tubes and significantly reduces the temperature of the flue gas exiting the stack. Too much heat picked up in the convection section is a sign of too much draft. Tube temperature is measured in both convection and radiant sections. Shield Section Just below the convection section is the shield (or shocktube) section, containing rows of tubing which shield the convection tubes from the direct radiant heat. Several important measurements are normally made just below the shield section. The bridgewall or breakwall temperature is the temperature of the flue gas after the radiant heat is removed by the radiant tubes and before it hits the convection section. Measurement of the draft at this point is also very important since this determines how well the heater is set up. Excess draft, either positive pressure or negative pressure, can lead to serious problems. This is also the ideal place for flue gas oxygen and ppm combustibles measurement. Breeching Sections and Stack The transition from the convection section to the stack is called the breeching. By the time the flue gas exits to the stack, most of the heat should be recovered and the temperature is much less. From a measurement point of view, this location places fewer demands on the analyzer but is much less desirable for the ability to control the process. Measurement of stack emissions for compliance purposes is normally made here.
  • 3. THERMOX® 3 MEETING PERFORMANCE OBJECTIVES The performance objectives of process heaters are similar to those of other process units: ► Maximize heat delivery of the process-side feed while minimizing fuel consumption. ► Maximize heat delivery with varying fuel quality. ► Minimize heater structural wear caused by operation. ► Minimize stack emissions (heat, CO, NOx ). ► Maximize safety integrity levels. Proper monitoring and control brings benefits and avoids problems in the following areas of heater operation: Energy Savings All process heaters consume large amounts of fuel to produce the necessary heat that must be transferred to the material brought into the furnace. Energy costs represent up to 65% of the cost of running a chemical/ petrochemical/refining complex. Furnace and heater fuel is the largest component of this cost. In the past, there was little reason to seek efficiency improvements as waste fuel was cheap and the excess was often flared. Today many of the refinery processes require hydrogen, and a lot of the hydrogen- rich off-gases, which were previously used as heater fuel, are now needed to meet this demand. Natural gas, which is very expensive, is used to make up shortfalls. Therefore the more energy that can be squeezed from existing plant fuels, the less supplementary natural gas is required. Correct use of gas analyzers can conserve the amount of fuel used and maximizes heater efficiency. NOx Reduction A significant fraction of NOx produced annually can be attributed to the chemical/ refining industry and stringent emission limits require greater control of NOx and other stack components. Operating the heater at optimum efficiency, with low excess air firing using oxygen and ppm combustibles, is the simplest and least expensive way to reduce NOx emissions. Product Quality Temperature control of the process tubes and reactions is critical in reforming and cracking operations. Since flaring is no longer permitted, gases with widely varying calorific content are now used as fuel for the heaters. This leads to large variations in heat delivered in the radiant section, and therefore, to greater demands on control of the product or feed temperature. Safety No information or incorrect information from a poorly placed analyzer can lead to unsafe operation of heaters from air leaks, tube leaks, and fuel or burner problems. Purge-down and light-off cycles require special care and warrant methane monitoring in addition to oxygen and ppm combustibles. Heater and Tube Life Incorrect operation leads to premature failure, structural damage or tube leaks due to flame impingement, secondary combustion and flue gas leaks. FACTORS AFFECTING PROCESS HEATER OPERATION Process heaters offer particular challenges for measurement and control due to: ► High temperature in the radiant zone where measurement is desired. ► Multiple burners. ► Multiple radiant zones (cells). ► Widely varying fuel calorific value. ► Low investment in heater optimization. A review of the factors affecting process heater performance will be useful . This includes draft, burner operation, combustion efficiency and NOx production.
  • 4. THERMOX® 4 Figure 3. Correct draft Figure 5. Excessive negative draftFigure 4. Excessive positive draft DRAFT For optimum operation, excess oxygen in the flue gas entering the convection section should be minimized and there should be a very small negative pressure at the convection section inlet. Correct Draft Refer to Figure 3. Stack dampers and secondary air registers affect the draft and both adjustments are related. The hot gas pushes so that the pressure is always greatest at the firewall. The stack draft pulls and when correctly balanced the pressure at the bridgewall should be close to zero or very slightly negative. A process heater operating properly will also have a zero, or slightly negative draft, at the shield section. The firebox will be slightly positive (+0.5 to +2.0 “ water column (wc)) and the stack will have a range of -0.5 to -1.0” wc. Excessive draft, either positive pressure or negative pressure, can lead to severe problems in the convection section. Excessive Draft — Positive Pressure Created In Figure 4, the air registers are wide open and the damper mostly closed. This generates a positive pressure which forces flue gases outward through leaks in the convection section leading to serious structure damage, as well as heat loss. Excessive Draft — Negative Pressure Created In Figure 5, the air registers are mostly closed and the stack damper is wide open leading to a high negative pressure in the convection section. Cold ambient air is sucked in through leaks in the convection section leading to erroneous oxygen readings, as well as heat loss. In addition the excessive draft causes tall flames which can reach the tubes resulting in serious damage. Zero or Slightly Negative Draft 0 or -0.1 to -0.5" WC Positive Draft +0.5 to +2.0" WC Damper STACK BREECHING CONVECTION SECTION SHIELD SECTION RADIANT SECTION Negative Draft -0.5 To -1.0" WC Damper WIDE OPEN -0.8" WC Air Registers MOSTLY CLOSED Cold Air Sucked In -0.8" WC -0.4" WC -0.6" WC Damper MOSTLY CLOSED Air Register WIDE OPEN -0.8" WC -0.3" WC +0.1" WC -0.1" WC Hot Flue Gas Blown Out
  • 5. THERMOX® 5 GAS PREMIX CHAMBER PRIMARY AIR REGISTER REFRACTORY BURNER TIP SECONDARY AIR REGISTER CARBON DIOXIDE WATER VAPOR OXYGEN NOx PPM COMBUSTIBLES (CO + H2) NITROGEN Figure 6. Burner with correct combustion air. CORRECT COMBUSTION AIR ► Good flame length ► Maximum flame temperature Combustion Efficiency and NOx Reduction The burners on a process heater premix the fuel with the primary air which is aspirated into the burner by the fuel gas flow (see Figure 6). The primary air flow should be maximized without lifting the flame off the burner. The pressure of the fuel gas supply is important since low gas pressure degrades performance. Most of the air (as primary air) is delivered to the burner along with the fuel. Secondary air is introduced and adjusted with the registers. Too much or too little secondary air gives poor combustion. Incomplete combustion occurs when not enough combustion air is supplied to burn all the fuel completely. The large amount of CO and H2 formed as a result of the incomplete combustion makes the burner extremely inefficient (Figure 7). This reduces the flame temperature and might encourage the operator to increase fuel flow thus making matters worse. This condition may not be noticed because leakage in the convection section can hide insufficient air getting to the burner. Completion of combustion in the convection section results in heater damage. GAS PREMIX CHAMBER PRIMARY AIR REGISTER REFRACTORY BURNER TIP SECONDARY AIR REGISTER Figure 7. Burner with insufficient combustion air. INSUFFICIENT COMBUSTION AIR ► Long flame ► Cooler temperature ► Very little NOx ► Very inefficient BURNER OPERATION Stoichiometric Combustion Under ideal conditions, fuel combines with exactly the right amount of oxygen to allow complete combustion. There is no unburned fuel and no excess oxygen. This is called stoichiometric combustion. In the simple case of methane burning in air, this can be written as CH4 + 2O2 → CO2 + 2H2 O Real combustion applications are more complicated because some excess air is always needed to ensure complete combustion of the fuel. Otherwise, significant amounts of CO are produced, reducing efficiency and increasing pollution levels.
  • 6. THERMOX® 6 Normally, six to ten thermocouples report the temperature stratification across the radiant section and this temperature profile of the radiant zone is used to determine the burner air/fuel ratio and to balance multiple burners. A visual observation of the flame is used to adjust the flame color and flame height based on the fuel pressure. After checking to see what type of temperature pattern is generated at the bridgewall, the burners can be adjusted accordingly. Once the flame is set correctly, the damper is adjusted for the correct draft. Finally, the secondary air supply is adjusted to give the desired oxygen reading or O2 setpoint. When set correctly, and with good air-fuel mixing, the burner will produce the maximum flame temperature in a compact flame. The less secondary air that is needed, the better the efficiency. At optimum efficiency, the flue gas will contain a minimum of oxygen together with levels of combustibles (CO and H2 ) in the 100 to 200 ppm range and a minimum of NOx. GAS PREMIX CHAMBER PRIMARY AIR REGISTER REFRACTORY BURNER TIP SECONDARY AIR REGISTER Figure 8. Burner with too much combustion air. TOO MUCH COMBUSTION AIR ► Short flame ► Cooler temperature ► Wasted heat ► Increased NOx NOx Production Too much combustion air reduces flame temperature and drops efficiency (Figure 8). In most applications this is the biggest source of heater inefficiency and NOx production. The high temperature in the flame and radiant section, together with combustion turbulence at the burners, causes dissociation of air molecules. The nitrogen and oxygen atoms combine to form nitric oxide (NO) and nitrogen dioxide (NO2 ), together known as NOx. The more combustion air, the more oxygen is available to produce NOx. Conversely the less oxygen the less chance of NOx formation (Figure 9). Figure 9. An example showing how NOx production increase with increasing excess air. NOx Production 0 50 100 150 200 250 300 1 2 3 4 5 % O2 PPMCO 0 20 40 60 80 100 PPMNOx Combustibles Nox WHAT IS THE CORRECT O2 SETPOINT?
  • 7. THERMOX® 7 WHAT IS THE CORRECT O2 SETPOINT? The Importance of Oxygen and Combustibles EXCESS AIR LOSSES COMBUSTIBLES LOSSES O2 & COMBUSTIBLES OPTIMUM CONTROL POINT 300 PPM 200 PPM 100 PPM O2 1% 4%3%2% EFFICIENCY COMBINED LOSSES O2-ONLY OPERATING SET POINT Figure 10. Determining optimum O2 setpoint. Reducing the excess air or oxygen to the minimum safe level is the most important step in reducing energy consumption. There is no single O2 level that is right for all heaters. The optimum oxygen level depends on the load, the burner design, the type of fuel, and the burner performance. Refer to Figure 10. Reducing oxygen while measuring the ppm combustibles allows the correct operating point to be determined. The actual value will depend on the variables mentioned previously and should be determined for each individual analyzer placement point. Without combustibles, it is not possible to find the optimum setpoint, since you cannot know when to stop reducing the combustion air. With the combustibles detector, the oxygen can be reduced safely until the combustibles starts to increase. This is the correct value for that heater. Combustibles has always been an important part of our combustion control strategy. Thermox used the term “combustibles” in 1975 to refer to the incomplete products of combustion in flue gas, primarily carbon monoxide and hydrogen. The detector is not designed to measure unburned fuel such as methane. Many operators have previously used percent level combustibles which is good for detecting serious process upsets or for precipitator protection, but has no benefit for optimizing combustion efficiency. For this, a reliable ppm combustibles measurement is needed. The latest generation of Thermox ppm combustibles detectors, perfected during 20 years of research and development, offers excellent reliability and performance. It is often thought that the oxygen measurement from a zirconia probe will also indicate when there is insufficient excess air. This is because any combustibles present will burn on the cell and reduce the displayed oxygen accordingly. While this is correct, the drop in oxygen only becomes significant when a major upset occurs. For example, a 2000 ppm (0.2%) level of combustibles or CO in the flue gas will reduce the O2 value by only 0.1%. A drop in oxygen from 3.0 to 2.9% will not be treated as significant by an operator. A reading of 2000 ppm on the combustibles detector at the same time would certainly be noticed, and acted upon. Why CO Measurement is Not Sufficient Although AMETEK does offer an infrared CO analyzer, a CO specific measurement is not a good choice for process heaters for a number of reasons. 1. Refinery fuel gases and other fuels used for process heaters have a varying H2 concentration and that is a critical component that must measured to achieve good heater efficiency. 2. The temperature limitations on infrared CO analyzers require installation after the convection section or in the stack. Improper burning or poor fuel quality can cause afterburning in the convection section which leads to convection tube bundle plugging and tube overheating. The IR analyzer mounted in the stack reading only CO will not pick this up. 3. The response time of an extractive CO analyzer on a sampling system is too slow. Analyzer location issues are discussed in more detail in the following sections.
  • 8. THERMOX® 8 PRIM ARYAIR SECONDARY AIR REGISTERS - MANUAL ADJUSTMENT CHAIN OPERATED DAMPERS FEED FEED PRIM ARY AIR XX X = TYPICAL O2 INSTALLATION POINT (ONE PER STACK) APPROX. 900°F REFRACTORY REFRACTORY FUEL FUEL FUEL and AIR - IDEAL INSTALLATION POINT APPROX. 1800°F Figure 11. Cabin furnace with three cells. ANALYZER CONSIDERATIONS A process heater is a complex combustion device with many variables to take into consideration. Control of the temperature of the feed inside the tubes relies greatly on precise control of the combustion process. Many heaters, reformers, and furnaces have multiple burners with two, three or more radiant sections (or cells). Proper control of the heater requires knowledge of the oxygen and combustibles levels of the flue gas as well as draft and temperature data. However, location of the oxygen analyzer greatly affects the validity of the measurement for control. It is almost impossible to operate a heater efficiently, effectively and safely with an oxygen measurement taken from the convection section or, even worse, from the stack. Figure 11 shows a cabin furnace with three separate radiant zones but many configurations exist. Most often the measurement is taken from the convection section (position X). How is it possible to relate an oxygen measurement from the convection section to what is happening in the burner zones? Answer: It is not. Moreover, leaks of air in the convection section will give erroneous oxygen readings and can mask problems in the burner zone. Ideally, the oxygen and combustibles should be measured in the firebox for three reasons: 1. To avoid erroneous readings caused by air leakage in the convection zone. 2. Combustibles in the flue gas will continue to burn on the hot tubes of the convective section and will not show the correct values at this location. 3. To be able to relate to the burners from that zone only. It is quite common for one or more burners to be operating with high combustibles levels. One sure sign of insufficient combustion air is that increasing fuel gas flow results in a decrease of process side temperature. Location
  • 9. THERMOX® 9 ANALYZER CONSIDERATIONS Aspirator Air Inlet Oxygen Sensor Combustibles Detector (if supplied) Wires Calibration Gas Line Aspirator Air Line Mounting Plate Temperature Controlled Furnace Boiler Wall Terminal Box Figure 12. Close-coupled O2 / combustibles analyzer. Zirconium Oxide Oxygen Cell PPM or Percent Combustibles Detector Cell Housing Convection Loop Return Aspirator Block Return to Process Methane Detector Sample Aspirator Air Figure 13. Convection loop of WDG-IVCM - O2 , combustibles and methane analyzer. Response The response time of an analyzer is not measured by the time it takes to react to calibration gas, but rather by its reaction to a process step change. Calibration gas is forced to the analyzer under pressure reaching the measuring cell very quickly so that all analyzers appear to be fast during calibration. The time it takes for the flue gas to get to the cell, on the other hand, depends upon the design of the system. When comparing analyzer response times, make sure you are looking at “process response”, not response to calibration gas. The close-coupled extractive WDG- IVC mounts directly to the process flange and is heated to maintain all sample wetted components above the acid dewpoint. An air-operated aspirator draws a sample into the analyzer and returns it to the process. A portion of this sample rises into the convection loop past the combustibles and oxygen cells and then back to process. This design gives a very fast response and is perfect for process heaters. The broad definition of the word “insitu” refers to an analyzer directly mounted to the process flange, rather than a remote location, with a sample conditioning system. “Insitu” can also refer to the distinction of whether the zirconia cell is located inside or outside of the flue gas duct. For low temperature (1250°F/677°C max.) locations, you can use a WDG- Insitu, with the zirconia cell residing in the flue gas stream. This type of analyzer has a slower response since it depends on diffusion of the flue gas to the cell, rather than on induced flow. A by-pass or cooling extension tube is often used for installation of insitu analyzers at higher temperature locations because of the probe temperature limit. In this configuration, it acts as a close-coupled extractive analyzer but with a slower response time. High temperature insitu analyzers, heated by the process and requiring a minimum process operating temperature of 1200°F (648°C), are available from some manufacturers. These have a slightly faster response time than standard insitus but tend to break more easily. They also cannot generate any process information during heater start-up. Both process- heated and self-heated insitus can measure only oxygen. Methane Detection During Start-up As an additional precaution during the purge-down and light-off cycle, the methane detector will detect any natural gas or other fuels which have leaked into the firebox and could cause an explosion. If the heater is started up only rarely, the methane detector would have limited use. When a heater or boiler is started-up frequently, then the methane measurement gives additional peace of mind. Thermox offers a combination O2 , combustibles and methane analyzer. The methane part is used only during the purge-down/ light-off cycle with natural gas-fired heaters. Once lit, the oxygen and combustibles measurements are used for optimization. Portable Versus Fixed (Dry Versus Wet O2 ) It is not a good idea to use the oxygen value determined from a portable analyzer as the set point for the fixed oxygen analyzer. The portable, typically fuel cell or paramagnetic based, measures on a dry basis since the water must be removed before the sample is analyzed. The fixed analyzer, normally zirconium oxide based, measures the flue gas as is, including the water and thus measures on a wet basis. The dry reading is always higher than the wet and the difference can be significant. When measuring a flue gas containing 20% moisture in the flue gas and 3% O2 , the fixed analyzer will read 3%, whereas the portable will read 3.75%. Neither is right or wrong. They are just different ways of looking at the same thing and in fact this principle is used to measure flue gas moisture. However, a setpoint value determined using the protable analyzer will not be the same as that determied using an in-situ measurement.
  • 10. THERMOX® 10 USING THERMOX OXYGEN AND PPM COMBUSTIBLES ANALYZERS FOR EFFICIENCYAND NOx REDUCTION Figure 14. Cabin furnace showing possible placement of analyzers. Figure 14 shows a cabin furnace with possible locations of the analyzers. The ideal locations are at the positions marked (1). At least one analyzer should be used for each radiant zone. In this case the probes are installed vertically going down into the firebox, but it is also possible to locate them with horizontal probes and with the analyzer mounted lower down on the furnace wall. Angled mounting is sometimes necessary. Depending upon the length of the cell, more than one analyzer may be required to get a representative measurement. Position (2) is much less desirable because the probe is now in the convection section. Air ingress tends to cause the readings to mask any burner problems if using oxygen only, but at least this will be picked up by the combustibles detector (make sure you have it!). This location gives no information on the cells, but rather some average of all the flue gas from that half of the cabin. Proper control of the furnace cannot be obtained with this approach. Comparison between (1) and (2) will give information on air leakage and if analyzers already exist at (2), they can be used for this purpose. Typically these are low temperature analyzers that anyway cannot be used in position (1). Position (3) should be used only for stack emissions measurement and should never be used for heater control. Thermox oxygen analyzers are designed for direct installation at the high temperature radiant section, typically 1500 - 2000°F (815 - 1093°C). A wide range of options is available, including hazardous area and floor mount versions. All parts are easily accessible and the analyzer can be serviced without having to take it off the flange. Suggested Manual Trim of a Fired Heater 1. Adjust primary air on the burner for proper flame height and color at the operating fuel gas pressure. 2. Adjust the stack damper to the recommended - 0.1” wc draft at the entrance to the convection section, with secondary air registers open. 3. Trim the secondary air registers to the lowest excess oxygen level up to, but not exceeding, the ppm combustibles operational limit as dictated by plant personnel/ or experience. 4. Readjust stack damper and secondary air registers as necessary to maintain convection section draft and minimal radiant section oxygen with a safe level of combustibles. 5. Set up the heater using oxygen and combustibles. The heater is now controlled on oxygen, and the combustibles detector is used to watch for process upsets and burner performance over time. This is your window into the process. 6. A 100 ppm combustibles level can achieve maximum fuel efficiency as well as minimizing emissions, without sacrificing safety.
  • 11. THERMOX® 11 EXPANDING HEATER CAPACITY CONCLUSION Not all heater situations can be improved with the above suggestions. Other classes of problems include: Heat release-limited The burner capacity limits furnace duty. An increase of gas pressure, or possibly increasing the burner orifice can increase capacity. High hydrogen content in the fuel gas can cause this. Draft-limited With the damper and registers wide open, there is still insufficient air. Air leakage into the convection section will not permit secondary air to enter the heater. Convection section tubes could also be partially plugged. Increasing secondary air opening size may remedy the situation. Heat absorption-limited The product can not obtain the target temperature. Add convective tubes, increase product mass velocity through tubes, adjust for dense flame. Heater operators often feel that they need only to maintain thermal objectives and this can be done by controlling the excess air using an oxygen-only analyzer. Or if there is no automatic trim on the heater, that Oxygen-only is sufficient. As we have shown, this is a misconception and even the smallest heater absolutely needs Oxygen and ppm combustibles. Slugs of waste gas with poor BTU value can hit the burners at any time and cause major and rapid changes to the combustion parameters. Measuring oxygen and ppm combustibles provides benefits far in excess of the analyzer(s) installed cost. 1. Improves efficiency - typically 3-5% fuel savings. 2. Reduces emissions - 15-20% NOx reduction is possible. 3. Identify problems due to air leaks. 4. Identify problems due to tube leaks. 5. Monitor burner performance. 6. Maintain product quality. 7. Improve heater and tube life. 8. Critical units such as reformers require multiple measuring points to provide sufficient information for proper process control. Thermox oxygen and combustibles analyzers can help meet heater performance objectives with minimal investment cost. Even older heaters with manual secondary air adjustments can benefit from optimization made possible by reliable oxygen and combustibles measurements from the correct location. All analyzers are available with a separate control unit to be located up to 1000 ft. (300 m) from the sensor, or as smart sensors (IQ versions). The smart sensors have all the electronics built into the sensor and are accessed via a handheld IQ Link or the LinkBus.
  • 12. © 2016, by AMETEK, Inc. All rights reserved. Printed in the U.S.A. F-0244 Rev. 4 (0216) One of a family of innovative process analyzer solutions from AMETEK Process Instruments. Specifications subject to change without notice. 150 Freeport Road, Pittsburgh, PA 15238 Ph. +1-412-828-9040, Fax +1-412-826-0399 www.ametekpi.com THERMOX® ApplicationNote SALES, SERVICE AND MANUFACTURING: USA - Pennsylvania 150 Freeport Road, Pittsburgh PA 15238 • Tel: +1-412-828-9040, Fax: +1-412-826-0399 USA - Delaware 455 Corporate Blvd., Newark DE 19702 • Tel: +1-302-456-4400, Fax: +1-302-456-4444 Canada - Alberta 2876 Sunridge Way N.E., Calgary AB T1Y 7H2 • Tel: +1-403-235-8400, Fax: +1-403-248-3550 WORLDWIDE SALES AND SERVICE LOCATIONS: USA - Houston, Texas Tel: +1-713-466-4900, Fax: +1-713-849-1924 BRAZIL Tel: +55 19 2107 4100 CHINA Beijing / Tel: +86 10 8526 2111, Fax: +86 10 8526 2141 Chengdu / Tel: +86 28 8675 8111, Fax: +86 28-8675 8141 Shanghai / Tel: +86 21 6426 8111, Fax: +86 21 6426 7818 FRANCE Tel: +33 1 30 68 89 20, Fax: +33 1 30 68 89 99 GERMANY Tel: +49 21 59 91 36 0, Fax: +49 21 59 91 3639 INDIA Tel: +91 80 6782 3200, Fax: +91 80 6782 3232 SINGAPORE Tel: +65 6484 2388, Fax: +65 6481 6588 SIMPLIFYING MAINTENANCE 0.10% H2S0.50% SO20.05% H2S 4.5% H2S 0.15% H2S0.45% H2S 0.10% H2S 0.10% H2S 0.10% H2S 0.10% H2S0.50% SO2 -12.56 -4.59 0.10% H2S Figure 15. LinkBus RIMS multiple analyzer view page The AMETEK LinkBus RIMS (Remote Instrument Monitoring System) provides the customer with plant-wide PC access to process analyzers using the existing web browser or through Fieldbus™, Modbus™ protocol-based DCS systems. The LinkBus system is available for IQ and 2000 controller-based Thermox flue gas analyzers, the 4000 and 880 Series photometric analyzers and the 5000 Series moisture analyzers. Easy access to analyzer information and trend data allows the maintenance department to make the most efficient use of limited resources and to determine process problems versus invalid analyzer data. The system can be configured by the user to allow third party access to factory personnel in order to provide expertise to assist in troubleshooting. The elimination of routine maintenance visits allows focused attention where it is most needed. Enhanced reliability and improved analyzer performance both lead to tighter process control.