A brilliant, compact instrument that clips onto your spirit level to convert it in seconds into a digital level & inclinometer. Suitable for ALL the Trades!
Accurate & simple to use, this can be used as a compact spirit level to measure true level or 90 degree plumb.
Or ALL angles in between with a 0.1 degree accuracy.
Designed to fit regular box section levels from 17mm to 23mm wide.
You can store measurements at the press of a button & the display is clear & easy to read.
It has endless uses for both the Professional & DIY'er alike.
The Path to Product Excellence: Avoiding Common Pitfalls and Enhancing Commun...
Model dwl 100 series clip on digital level
1. Model DWL 100 Series
The DWL 100 products are primarily designed for extreme convenience to be attached
on Traditional Spirit Levels,commonly available and to INSTANTLY transform these
Spirit Levels into Digital Level.
Models:
Clip on Models Special Feature
DWL 100CWP Resolution 0.1°
DWL 180CWP Resolution 0.05°
Dimension L(95) x H(48) x T(32) mm
Screw on models Special Feature
DWL 100S Resolution 0.1°
DWL 180S Resolution 0.05°
Dimension L(118) x H(48.5) x T(16) mm
Features & Specification: Application:
Measurement Range 0°~ +/- 90°
High Resolution 0.05°~ 0.1°
Operating Temperature 0°~ 50°C
Long Battery Life with 3 minutes auto off
Easy, Clear & Precise Digital Display
Hold Function to Freeze Display
Buzzer Sound
Power supply 2 x 3v Lithium cell
(Batteries included)
For further information, please refer to www.digipas.co.uk
2. OPERATION
CALIBRATION INSTRUCTION a) Batteries:
Caution: Digi-Pas is calibrated in the Factory Open the battery compartment at
for maximum accuracy. User only the rare of the Digi-Pas .
recalibrate unless necessary. Remove the small plastic from two
new batteries (type AAA/LR03).
1. Push ONCE on the Cal button then Ensure correct polarity.
release. Buzzer starts to beep. b) Switching on the Digi-Pas:
2a. Place Digi-Pas on a flat surface (e.g. Switch the Digi-Pas on using the
Table) Use a finger to Press Mode button on/off switch.
ONCE while wait a few seconds until buzzer The Digi-Pas can measure angles
beeps. range 0°~ +/- 90°
b. Place Digi-Pas reverse horizontal (180°) c) Buzzer Sound (Acoustic signal):
Press Mode button ONCE and wait a few The Buzzer Sound are used to
seconds until buzzer beeps. indicated angle of slope stands at 0°,
c. Place Digi-Pas vertically (-90° and) 45° 90°
, ,
Press Mode button ONCE and wait a few To switch off Acoustic signal, hold
seconds until buzzer beeps. the Mode for more than 2 seconds,
d. Place Digi-Pas reverse vertically (+90°) the speaker anunciator will be
and Press Mode button ONCE and wait a few disappeared.
seconds until buzzer beeps. d) Hold button (Memory functions)
3. Calibration completes when buzzer beep With the hold button, you can
sound stops. Freeze Display for reading and the
NOTE : Ensure Digi-pas is kept still during current measurement result can be
Calibration saved in the internal memory.
Return to normal measuring mode
by pressing Hold button
To call back the reading in the
internal memory, press Hold button
for 3 second. The previous save
reading will be appearing in the
display.
e) Switching off:
To switch off the Digi-Pas, press the
on/off switch (1) .When not in use
more than 3 min, the Digi-Pas will
switches off automatically.
UK and Europe sales office
TARAX TECHNOLOGY LTD
First Floor, Office 2,
10 Panmure Street,
Dundee,
DD1 2BW.
e:Info@digipas.co.uk
w:www.digipas.co.uk
t:(+44)01382520129
m:(+44)07825041403