When it comes to designing, building, and operating mission critical data centers, simple is better. Prefabricated data center building blocks comprised of Power, Cooling and/or IT White Space can be connected to provide a semi or fully prefabricated data center solution. Prefabricated data center solutions provide multiple advantages to include predictable performance, faster deployment and, flexibility and scalability versus traditional build data centers. This presentation will show you how a pre-fabricated modular data center architecture can dramatically simplify your design and build process and lower your total cost of operation.
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
The Data Center Evolution and Pre-Fab Data Centers
1. Prefabricated Data Center Solutions:
The Coming Age...
Mark Hurley- Vice President, Solution Architect
Schneider Electric IT Business
DatacenterDynamics – Santa Clara – June 2014
Schneider Electric 1
2. Data Center Pressures & Expectations
Reduce Capital Costs
Reduce Operating Costs
Manage / Right Size Risk
Improve Speed to Market
Your ability to compete and differentiate successfully
starts with the design and build of your data center…
Schneider Electric 2
3. The Answer…Dramatically SIMPLIFY
Prefabricated Architecture
Integrated DCIM Software
Reference Resigns
Prefabricated Data Center
Simplified Design/Build
Simplification reduces cost, speed to market, and complexity
Schneider Electric 3
4. Prefabricated data center solutions have evolved
over time…
Power Equipment
Centers
Power Zone
Centers
Power and Cooling
Centers
Electrical Distribution
Centers
Packaged
Chillers
1950
EcoBreeze InfrastruXure
2006 2003
2011 2012
Prefab Assemblies
2009
Power & Chilled Water
Proof of Concepts
InfrastruXure
Express
Higher Volume
ETO Modules Non- ISO Containers
Prefab Building Blocks
2014
Schneider Electric 4
5. The industry has many players and approaches to
Prefabricated Data Centers…
Schneider Electric 5
6. Promises from the industry
Lower Cost
Faster and
Easier
Standardized
Why hasn’t this worked?
Schneider Electric 6
7. Customers are not convinced of the benefits:
● Initial product introductions were just proof-of-concepts
● Early prefabricated ISO container solutions were too
restrictive
● Initial prefabricated cost advantage claims were
exaggerated
● Unique data center requirements are not aligned
with the standardized offer from many vendors
When the industry provides the right pieces at the right
cost then prefabrication will get momentum.
Schneider Electric 7
8. 5 criteria to success for prefabricated data centers…
Multiple building block types and capacities
Engineered reference designs
Global capabilities
Vendor support – Assess, Plan, Design, Build, Operate
Integrated DCIM software into building blocks
Schneider Electric 8
9. The range of applications demands different
types of modules and form factors
Cooling IT Space Power
Power Module - Exterior Power Module - Interior
Power Skid
Single Bay / Dual Bay Multi Bay Smart Shelter
Packaged Chiller and Hydronics
Hydronics Module EcoBreeze Evap Cooler
Schneider Electric 9
10. Reference designs simplify the design process
…and should be freely available Downloadable from a web site
● Library of engineered data center
reference designs
● System level specifications
● PUE, Price, Density, Layout
● Complete schematics and BOMs
● Fully and Semi-Prefabricated data center
designs
Schneider Electric 10
11. Reference designs improve speed to market
…and should be freely available Downloadable from a web site
• Use as a base plan to design and build
your data center Starting Point
• Preview, compare, and even combine
different designs Compare
• Gain a better understanding of costs,
performance, size, and players Analyze
Customize • Apply preferences and constraints
Refine • Conceptualize and refine end result
Schneider Electric 11
12. Example: Semi-Prefabricated Data Center
Reference Design #34 – 2 MW Tier III
(2) 1000 kW
Hydronics Modules
(6) 500 kW
Chillers
(2) IT Halls
(4) 1200 kW
Power Skids
Schneider Electric 12
13. Example: Fully Prefabricated Data Center
Reference Design #23 – 500 kW Tier II
(2) 250 kW
Power Modules
(2) 240 kW, 22 rack
IT Modules
(3) 250 kW
Chillers
(1) 500 kW
Hydronics Module
Schneider Electric 13
14. Global capabilities
Manufacturing, Engineering Design, Support
North America
Asia Pacific
EMEA
China
Manufacturing Site
Global R&D Team
Regional Design Center
Demo Center
Schneider Electric 14
15. Customer supply needs have evolved from
providing components to providing solutions
SUBSYSTEMS
COMPONENTS
Schneider Electric 15
Foundational BUSINESS OVERVIEW Rev 4a
SOLUTIONS
Solutions
Innovative combination of technology, products
and services providing an integrated response
Subsystems
IT Room, Facility Power, Facility Cooling,
Security, DCIM
Components
16. Prefab solutions require assistance
Assessment Services
• for existing or planned facilities or sites to
understand viability of using prefabrication
Planning Services
• to demonstrate where prefabrication
could benefit performance, cost or timing
Design and Build Services
• Reference design starting points
• Data centers with all prefabricated modules
• Hybrid data center with mix of prefabricated modules and
traditional
• Project management including installation management, site
coordination, and construction coordination
Schneider Electric 16
17. All prefab should be smart ‘out of box’
Fully instrumented and programmed in each building block
Schneider Electric 17
19. Prefabricated Data Centers provide many
advantages . . .
Predictable
Performance
• The density, availability
and efficiency you
expected
• The cost you were
promised
• Less “hands” involved,
less changes to design
Faster
Deployment
• Shorten planning cycle
and reduce complexity
• Simplify design and build
process
• Delivery in 12-16 weeks or
less (upon sign-off and
receipt of final drawings)
. . . vs. traditional data centers
Flexibility and
Scalability
• Defer capital expenses and
minimize over sizing.
• Adjust quickly changes in
demand, up or down.
• Deploy in various
configurations of density
and availability
Schneider Electric 19
20. Prefabrication, Reference Designs and integrated
DCIM software simplify the data center life cycle…
Reference Designs
simplify and shorten the Plan
and Design phases of a data
center design/build cycle
Design and Build
cycles are simplified with
Prefabricated modular
building blocks
Operations
are simplified with fully
instrumented
Prefabricated
modular data centers
Schneider Electric 20
21. Prefabricated subsystems facilitate modular and
scalable build-outs, preserve capital and improve
energy efficiency…
Modular and Scalable Data Center
Future Expansion
IT Pods
IT
Power
Cooling
Pre-fabricated Modular Architecture
Power
Cooling
IT Pods
Schneider Electric 21
22. Prefabricated data centers will come of age when…
1. When suppliers offer tools and services to support decision making
for prefabrication vs. traditional build
2. When building blocks of various ratings, technologies, and form
factors are available at competitive price points
3. When suppliers are able to deliver an entire solution:
assess, plan, design, build and operate a prefabricated data center
Schneider Electric 22
23. Make the most of
your energy™
Questions?
Schneider Electric 23
24. Schneider Electric is a Prefabricated Data Center
Solution Provider – visit us on the web:
● Prefabricated Product Pages
http://www.apc.com/products/category.cfm?id=22
● Solution Pages on Schneider-Electric.com
http://www2.schneider-electric.com/sites/corporate/en/solutions/solutions-by-expertise.page
● Prefabricated Trade-Off Tool (coming soon)
http://teamwork.schneider-electric.com/datacenteroffer/default.aspx
● White Paper #163 Containerized Power & Cooling Modules for
Data Centers
http://www.apcmedia.com/salestools/WTOL-7NGRBS/WTOL-7NGRBS_R1_EN.pdf
● White Paper #165 Types of Prefabricated Data Centers (coming soon)
http://www.apc.com/prod_docs/results.cfm?DocType=White%20Paper&Query_Type=10
● Reference Design Video
http://tv.schneider-electric.com/site/schneiderTV/index.cfm?video=QxN2lmNzrJnhvX-zGHECmZ71HGLW2Wjw#
ooid=QxN2lmNzrJnhvX-zGHECmZ71HGLW2Wjw
Schneider Electric 24