Idle Mode – 4G <-> 4G
L800 (10 MHz) – L1
L800 Absolute Priority = 4
L1800 Relative Priority = 2
L2100 Relative Priority = 5
L2300 Relative Priority = 5
qrxlevmin = -124 dBm
qQualminR9 = -20 dB
Qhyst = 2dBs
L1800 (5 MHz) – L2
L2100 (10 MHz) – L7
qrxlevmin = -120 dBm
qQualminR9 = -20 dB
Qhyst = 2dBs
qrxlevmin = -120 dBm
qQualminR9= -20 dB
Qhyst = 2dBs
L2300 (20 MHz) – L4
qrxlevmin = -124 dBm
qQualminR9 = -20 dB
Qhyst = 2dBs
L1800 Absolute Priority = 4
L800 Relative Priority = 3
L2100 Relative Priority = 7
L2300 Relative Priority = 5
L2100 Absolute Priority = 5
L800 Relative Priority = 4
L2300 Relative Priority = 6
L2300 Absolute Priority = 5
L800 Relative Priority = 4
sNonIntrasearchQR9 = -14 dB
sNonIntrasearchPR9 = -116 dBm
sIntrasearchQR9 = 11 dB
sIntrasearchPR9 = -62 dBm
threshSrvLow = -120 dBm
thresholdXL = -120 dBm
threshServingLowQR9= -18 dB
interfrqQThrLowR9= -18 dB
threshSrvLow = -116 dBm
thresholdXL = -120 dBm
thresholdXH = -116 dBmI
threshServingLowQR9= -18 dB
interfrqQThrLowR9= -18 dB
interfrqQThrHighR9= -10 dB
sNonIntrasearchQR9 = -14 dB
sNonIntrasearchPR9 = -116 dBm
sIntrasearchQR9 = 11 dB
sIntrasearchPR9 = -62 dBm
sNonIntrasearchQR9 = -14 dB
sNonIntrasearchPR9 = -116 dBm
sIntrasearchQR9 = 11 dB
sIntrasearchPR9 = -62 dBm
sNonIntrasearchQR9 = -14 dB
sNonIntrasearchPR9 = -116 dBm
sIntrasearchQR9 = 11 dB
sIntrasearchPR9 = -62 dBm
threshSrvLow = -116 dBm
thresholdXL = -120 dBm
thresholdXH = -112 dBmI
threshServingLowQR9= -18 dB
interfrqQThrLowR9= -18 dB
interfrqQThrHighR9= -16 dB
threshSrvLow = -120 dBm
thresholdXL = -116 dBm
thresholdXH = -116 dBmI
threshServingLowQR9= -18 dB
interfrqQThrLowR9= -18 dB
interfrqQThrHighR9= -10 dB
Connected Mode – PS Data
L800 (10 MHz) – L1
qrxlevmin = -124 dBm
L1800 (5 MHz) – L2
L2100 (10 MHz) – L7
qrxlevmin = -120 dBm
qrxlevmin = -120 dBm
L2300 (20 MHz) – L4
qrxlevmin = -124 dBm
A3 event
threshold2InterFreq = -116 dBm
a3OffsetRsrpInterFreq = 3 dB
A5 event
threshold3Interfreq = -115 dBm
threshold3aInterfreq = -114 dBm
threshold4 = -120 dBm (Priority = L800)
threshold2Wcdma = -130 dBm
b2Threshold1Utra = - 130 dBm
threshold2GERAN = -140 dBm
b2Threshold1GERAN = -75 dBm
b2Threshold2UtraEcn0 = -14 dB
b2Threshold2UtraRscp = -110 dBm
To 3G
A3 event
threshold2InterFreq = -116 dBm
a3OffsetRsrpInterFreq = 3 dB
A5 event
threshold3Interfreq = -115 dBm
threshold3aInterfreq = -114 dBm
A3 event
threshold2InterFreq = -112 dBm
a3OffsetRsrpInterFreq = 3 dB
A5 event
threshold3Interfreq = -115 dBm
threshold3aInterfreq = -114 dBm
A3 event
threshold2InterFreq = -140 dBm
a3OffsetRsrpInterFreq = 3 dB
A5 event
threshold3Interfreq = -115 dBm
threshold3aInterfreq = -114 dBm
threshold4 = -120 dBm (Priority = L800)
threshold2MobRsrq = -17dB
threshold4RsRq = -19dB
threshold2Wcdma = -130 dBm
b2Threshold1Utra = - 130 dBm
threshold2GERAN = -140 dBm
b2Threshold1GERAN = -75 dBm
threshold4 = -116 dBm (Priority = L800)
threshold2Wcdma = -130 dBm
b2Threshold1Utra = - 130 dBm
threshold2GERAN = -140 dBm
b2Threshold1GERAN = -75 dBm
threshold4 = -124 dBm (Priority = U900)
threshold2Wcdma = -120 dBm
b2Threshold1Utra = - 120 dBm
threshold2GERAN = -140 dBm
b2Threshold1GERAN = -75 dBm
b2Threshold2RssiGERAN = -100 dBm
To 2G
Connected Mode – AMLE Load Balancing
L800 (10 MHz) – L1
qrxlevmin = -124 dBm
L1800 (5 MHz) – L2
L2100 (10 MHz) – L7
qrxlevmin = -120 dBm
qrxlevmin = -120 dBm
nomNumPrbNonGbr = 0.005 (5)
iFLBHighLoadNonGBRDL = 85%
L2300 (20 MHz) – L4
qrxlevmin = -124 dBm
nomNumPrbNonGbr = 0.1 (100)
iFLBHighLoadNonGBRDL = 85%
nomNumPrbNonGbr = 0.2 (200)
iFLBHighLoadNonGBRDL = 85%
nomNumPrbNonGbr = 0.5 (500)
iFLBHighLoadNonGBRDL = 85%
thresholdRsrpIFLBFilter = -110 dBm
thresholdRsrqIFLBFilter = -14 dB
maxCacThreshold = 100%
deltaCac = 2%
thresholdRsrpIFLBFilter = -110 dBm
thresholdRsrqIFLBFilter = -14 dB
maxCacThreshold = 100%
deltaCac = 2%
thresholdRsrpIFLBFilter = -110 dBm
thresholdRsrqIFLBFilter = -14 dB
maxCacThreshold = 100%
deltaCac = 2%
thresholdRsrpIFLBFilter = -110 dBm
thresholdRsrqIFLBFilter = -14 dB
maxCacThreshold = 100%
deltaCac = 2%
Connected Mode – VoLTE
L800 (10 MHz) – L1
qrxlevmin = -124 dBm
L1800 (5 MHz) – L2
L2100 (10 MHz) – L7
qrxlevmin = -120 dBm
qrxlevmin = -120 dBm
L2300 (20 MHz) – L4
qrxlevmin = -124 dBm
A3 event
threshold2InterFreq = -116 dBm
a3OffsetRsrpInterFreq = 3 dB
A5 event
threshold3Interfreq = -115 dBm
threshold3aInterfreq = -114 dBm
threshold4 = -120 dBm (Priority = L800)
threshold2WcdmaQCI1 = -118 dBm
b2Threshold1UtraQCI1 = - 75 dBm
threshold2GERANQCI1 = -119 dBm
b2Threshold2UtraEcn0 = -14 dB
b2Threshold2UtraRscp = -110 dBm
To 3G
A3 event
threshold2InterFreqQCI1 = -112 dBm
a3OffsetRsrpInterFreq = 3 dB
A5 event
threshold3Interfreq = -115 dBm
threshold3aInterfreq = -114 dBm
A3 event
threshold2InterFreq = -112 dBm
a3OffsetRsrpInterFreq = 3 dB
A5 event
threshold3Interfreq = -115 dBm
threshold3aInterfreq = -114 dBm
A3 event
threshold2InterFreq = -140 dBm
a3OffsetRsrpInterFreq = 3 dB
A5 event
threshold3Interfreq = -115 dBm
threshold3aInterfreq = -114 dBm
threshold4 = -120 dBm (Priority = L800)
threshold2WcdmaQCI1 = -114 dBm
b2Threshold1UtraQCI1 = - 75 dBm
threshold2GERANQCI1 = -115 dBm
threshold4 = -116 dBm (Priority = L800)
threshold2WcdmaQCI1 = -114 dBm
b2Threshold1UtraQCI1 = - 75 dBm
threshold2GERANQCI1 = -115 dBm
threshold4 = -124 dBm (Priority = U900)
threshold2WcdmaQCI1 = -118 dBm
b2Threshold1UtraQCI1 = - 75 dBm
threshold2GERANQCI1 = -119 dBm
b2Threshold2RssiGERAN = -100 dBm
To 2G

Weitere Àhnliche Inhalte

Ähnlich wie TEF UK 4G O2 UK Mobility Strategy Baseline-v47.pdf

RF—project
RF—projectRF—project
RF—project
HE LIU
 
Applied motion products stm datasheet
Applied motion products stm datasheetApplied motion products stm datasheet
Applied motion products stm datasheet
Electromate
 

Ähnlich wie TEF UK 4G O2 UK Mobility Strategy Baseline-v47.pdf (20)

IQxel-MW-7G-TechSpecs-022423-web.pdf
IQxel-MW-7G-TechSpecs-022423-web.pdfIQxel-MW-7G-TechSpecs-022423-web.pdf
IQxel-MW-7G-TechSpecs-022423-web.pdf
 
RF—project
RF—projectRF—project
RF—project
 
GPS sensitivity questions and its HW RF consideration
GPS sensitivity questions and its HW RF considerationGPS sensitivity questions and its HW RF consideration
GPS sensitivity questions and its HW RF consideration
 
AAAAAAAAAAAA,,,.....$$AAAAAAA
AAAAAAAAAAAA,,,.....$$AAAAAAAAAAAAAAAAAAA,,,.....$$AAAAAAA
AAAAAAAAAAAA,,,.....$$AAAAAAA
 
B2 desence
B2 desenceB2 desence
B2 desence
 
10Gb/s DWDM XFP Transceiver Hot Pluggable, Duplex LC, +3.3V & +5V, 100GHz ITU...
10Gb/s DWDM XFP Transceiver Hot Pluggable, Duplex LC, +3.3V & +5V, 100GHz ITU...10Gb/s DWDM XFP Transceiver Hot Pluggable, Duplex LC, +3.3V & +5V, 100GHz ITU...
10Gb/s DWDM XFP Transceiver Hot Pluggable, Duplex LC, +3.3V & +5V, 100GHz ITU...
 
Rf2008 test 1
Rf2008 test 1Rf2008 test 1
Rf2008 test 1
 
10Gb/s DWDM XFP Transceiver Hot Pluggable, Duplex LC, +3.3V & +5V, 100GHz ITU...
10Gb/s DWDM XFP Transceiver Hot Pluggable, Duplex LC, +3.3V & +5V, 100GHz ITU...10Gb/s DWDM XFP Transceiver Hot Pluggable, Duplex LC, +3.3V & +5V, 100GHz ITU...
10Gb/s DWDM XFP Transceiver Hot Pluggable, Duplex LC, +3.3V & +5V, 100GHz ITU...
 
10Gb/s DWDM SFP+ Transceiver Hot Pluggable, Duplex LC, +3.3V, 100GHz ITU Grid...
10Gb/s DWDM SFP+ Transceiver Hot Pluggable, Duplex LC, +3.3V, 100GHz ITU Grid...10Gb/s DWDM SFP+ Transceiver Hot Pluggable, Duplex LC, +3.3V, 100GHz ITU Grid...
10Gb/s DWDM SFP+ Transceiver Hot Pluggable, Duplex LC, +3.3V, 100GHz ITU Grid...
 
10Gb/s 80km DWDM SFP+ Transceiver Hot Pluggable, Duplex LC, +3.3V, 100GHz ITU...
10Gb/s 80km DWDM SFP+ Transceiver Hot Pluggable, Duplex LC, +3.3V, 100GHz ITU...10Gb/s 80km DWDM SFP+ Transceiver Hot Pluggable, Duplex LC, +3.3V, 100GHz ITU...
10Gb/s 80km DWDM SFP+ Transceiver Hot Pluggable, Duplex LC, +3.3V, 100GHz ITU...
 
synthetic aperture radar
synthetic aperture radarsynthetic aperture radar
synthetic aperture radar
 
loa AD Modular 10
loa AD Modular 10loa AD Modular 10
loa AD Modular 10
 
RIGOL Real-time spectrum analyzer RSA5000 Series
RIGOL Real-time spectrum analyzer RSA5000 SeriesRIGOL Real-time spectrum analyzer RSA5000 Series
RIGOL Real-time spectrum analyzer RSA5000 Series
 
Active Filter Design Using PSpice
Active Filter Design Using PSpiceActive Filter Design Using PSpice
Active Filter Design Using PSpice
 
Applied motion products stm datasheet
Applied motion products stm datasheetApplied motion products stm datasheet
Applied motion products stm datasheet
 
Link budget
Link budgetLink budget
Link budget
 
Datasheet Fluke 96000 Extended Specification. Hubungi PT. Siwali Swantika 021...
Datasheet Fluke 96000 Extended Specification. Hubungi PT. Siwali Swantika 021...Datasheet Fluke 96000 Extended Specification. Hubungi PT. Siwali Swantika 021...
Datasheet Fluke 96000 Extended Specification. Hubungi PT. Siwali Swantika 021...
 
IEEE_RFIC 2007
IEEE_RFIC 2007 IEEE_RFIC 2007
IEEE_RFIC 2007
 
Optical design
Optical designOptical design
Optical design
 
Preparing PRF
Preparing PRFPreparing PRF
Preparing PRF
 

Mehr von LibaBali (9)

Drive_Test_Analysis_DTA_4G_LTE.docx
Drive_Test_Analysis_DTA_4G_LTE.docxDrive_Test_Analysis_DTA_4G_LTE.docx
Drive_Test_Analysis_DTA_4G_LTE.docx
 
LTE_poster.pdf
LTE_poster.pdfLTE_poster.pdf
LTE_poster.pdf
 
LTE_A_Telecoma_new.pptx
LTE_A_Telecoma_new.pptxLTE_A_Telecoma_new.pptx
LTE_A_Telecoma_new.pptx
 
dokumen.tips_ericsson-lte-throughput-troubleshooting-techniques_SUPERRRRRRR.ppt
dokumen.tips_ericsson-lte-throughput-troubleshooting-techniques_SUPERRRRRRR.pptdokumen.tips_ericsson-lte-throughput-troubleshooting-techniques_SUPERRRRRRR.ppt
dokumen.tips_ericsson-lte-throughput-troubleshooting-techniques_SUPERRRRRRR.ppt
 
06.pptx
06.pptx06.pptx
06.pptx
 
393575910-318163030-E2E-VOLTE-pptx.pptx
393575910-318163030-E2E-VOLTE-pptx.pptx393575910-318163030-E2E-VOLTE-pptx.pptx
393575910-318163030-E2E-VOLTE-pptx.pptx
 
dokumen.tips_ericsson-lte-throughput-troubleshooting-techniquesppt.ppt
dokumen.tips_ericsson-lte-throughput-troubleshooting-techniquesppt.pptdokumen.tips_ericsson-lte-throughput-troubleshooting-techniquesppt.ppt
dokumen.tips_ericsson-lte-throughput-troubleshooting-techniquesppt.ppt
 
L2_Wireshark.ppt
L2_Wireshark.pptL2_Wireshark.ppt
L2_Wireshark.ppt
 
10.1152-advan.00083.2007Figure1.pptx
10.1152-advan.00083.2007Figure1.pptx10.1152-advan.00083.2007Figure1.pptx
10.1152-advan.00083.2007Figure1.pptx
 

KĂŒrzlich hochgeladen

Why Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire businessWhy Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire business
panagenda
 
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
?#DUbAI#??##{{(☎+971_581248768%)**%*]'#abortion pills for sale in dubai@
 
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers:  A Deep Dive into Serverless Spatial Data and FMECloud Frontiers:  A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Safe Software
 

KĂŒrzlich hochgeladen (20)

presentation ICT roal in 21st century education
presentation ICT roal in 21st century educationpresentation ICT roal in 21st century education
presentation ICT roal in 21st century education
 
Navi Mumbai Call Girls đŸ„° 8617370543 Service Offer VIP Hot Model
Navi Mumbai Call Girls đŸ„° 8617370543 Service Offer VIP Hot ModelNavi Mumbai Call Girls đŸ„° 8617370543 Service Offer VIP Hot Model
Navi Mumbai Call Girls đŸ„° 8617370543 Service Offer VIP Hot Model
 
AWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of TerraformAWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of Terraform
 
Why Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire businessWhy Teams call analytics are critical to your entire business
Why Teams call analytics are critical to your entire business
 
MS Copilot expands with MS Graph connectors
MS Copilot expands with MS Graph connectorsMS Copilot expands with MS Graph connectors
MS Copilot expands with MS Graph connectors
 
Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024
 
EMPOWERMENT TECHNOLOGY GRADE 11 QUARTER 2 REVIEWER
EMPOWERMENT TECHNOLOGY GRADE 11 QUARTER 2 REVIEWEREMPOWERMENT TECHNOLOGY GRADE 11 QUARTER 2 REVIEWER
EMPOWERMENT TECHNOLOGY GRADE 11 QUARTER 2 REVIEWER
 
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
 
Artificial Intelligence Chap.5 : Uncertainty
Artificial Intelligence Chap.5 : UncertaintyArtificial Intelligence Chap.5 : Uncertainty
Artificial Intelligence Chap.5 : Uncertainty
 
Emergent Methods: Multi-lingual narrative tracking in the news - real-time ex...
Emergent Methods: Multi-lingual narrative tracking in the news - real-time ex...Emergent Methods: Multi-lingual narrative tracking in the news - real-time ex...
Emergent Methods: Multi-lingual narrative tracking in the news - real-time ex...
 
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost SavingRepurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
 
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers:  A Deep Dive into Serverless Spatial Data and FMECloud Frontiers:  A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
 
Data Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt RobisonData Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt Robison
 
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
 
Strategies for Landing an Oracle DBA Job as a Fresher
Strategies for Landing an Oracle DBA Job as a FresherStrategies for Landing an Oracle DBA Job as a Fresher
Strategies for Landing an Oracle DBA Job as a Fresher
 
"I see eyes in my soup": How Delivery Hero implemented the safety system for ...
"I see eyes in my soup": How Delivery Hero implemented the safety system for ..."I see eyes in my soup": How Delivery Hero implemented the safety system for ...
"I see eyes in my soup": How Delivery Hero implemented the safety system for ...
 
Automating Google Workspace (GWS) & more with Apps Script
Automating Google Workspace (GWS) & more with Apps ScriptAutomating Google Workspace (GWS) & more with Apps Script
Automating Google Workspace (GWS) & more with Apps Script
 
Corporate and higher education May webinar.pptx
Corporate and higher education May webinar.pptxCorporate and higher education May webinar.pptx
Corporate and higher education May webinar.pptx
 
Apidays New York 2024 - Accelerating FinTech Innovation by Vasa Krishnan, Fin...
Apidays New York 2024 - Accelerating FinTech Innovation by Vasa Krishnan, Fin...Apidays New York 2024 - Accelerating FinTech Innovation by Vasa Krishnan, Fin...
Apidays New York 2024 - Accelerating FinTech Innovation by Vasa Krishnan, Fin...
 
A Year of the Servo Reboot: Where Are We Now?
A Year of the Servo Reboot: Where Are We Now?A Year of the Servo Reboot: Where Are We Now?
A Year of the Servo Reboot: Where Are We Now?
 

TEF UK 4G O2 UK Mobility Strategy Baseline-v47.pdf

  • 1. Idle Mode – 4G <-> 4G L800 (10 MHz) – L1 L800 Absolute Priority = 4 L1800 Relative Priority = 2 L2100 Relative Priority = 5 L2300 Relative Priority = 5 qrxlevmin = -124 dBm qQualminR9 = -20 dB Qhyst = 2dBs L1800 (5 MHz) – L2 L2100 (10 MHz) – L7 qrxlevmin = -120 dBm qQualminR9 = -20 dB Qhyst = 2dBs qrxlevmin = -120 dBm qQualminR9= -20 dB Qhyst = 2dBs L2300 (20 MHz) – L4 qrxlevmin = -124 dBm qQualminR9 = -20 dB Qhyst = 2dBs L1800 Absolute Priority = 4 L800 Relative Priority = 3 L2100 Relative Priority = 7 L2300 Relative Priority = 5 L2100 Absolute Priority = 5 L800 Relative Priority = 4 L2300 Relative Priority = 6 L2300 Absolute Priority = 5 L800 Relative Priority = 4 sNonIntrasearchQR9 = -14 dB sNonIntrasearchPR9 = -116 dBm sIntrasearchQR9 = 11 dB sIntrasearchPR9 = -62 dBm threshSrvLow = -120 dBm thresholdXL = -120 dBm threshServingLowQR9= -18 dB interfrqQThrLowR9= -18 dB threshSrvLow = -116 dBm thresholdXL = -120 dBm thresholdXH = -116 dBmI threshServingLowQR9= -18 dB interfrqQThrLowR9= -18 dB interfrqQThrHighR9= -10 dB sNonIntrasearchQR9 = -14 dB sNonIntrasearchPR9 = -116 dBm sIntrasearchQR9 = 11 dB sIntrasearchPR9 = -62 dBm sNonIntrasearchQR9 = -14 dB sNonIntrasearchPR9 = -116 dBm sIntrasearchQR9 = 11 dB sIntrasearchPR9 = -62 dBm sNonIntrasearchQR9 = -14 dB sNonIntrasearchPR9 = -116 dBm sIntrasearchQR9 = 11 dB sIntrasearchPR9 = -62 dBm threshSrvLow = -116 dBm thresholdXL = -120 dBm thresholdXH = -112 dBmI threshServingLowQR9= -18 dB interfrqQThrLowR9= -18 dB interfrqQThrHighR9= -16 dB threshSrvLow = -120 dBm thresholdXL = -116 dBm thresholdXH = -116 dBmI threshServingLowQR9= -18 dB interfrqQThrLowR9= -18 dB interfrqQThrHighR9= -10 dB
  • 2. Connected Mode – PS Data L800 (10 MHz) – L1 qrxlevmin = -124 dBm L1800 (5 MHz) – L2 L2100 (10 MHz) – L7 qrxlevmin = -120 dBm qrxlevmin = -120 dBm L2300 (20 MHz) – L4 qrxlevmin = -124 dBm A3 event threshold2InterFreq = -116 dBm a3OffsetRsrpInterFreq = 3 dB A5 event threshold3Interfreq = -115 dBm threshold3aInterfreq = -114 dBm threshold4 = -120 dBm (Priority = L800) threshold2Wcdma = -130 dBm b2Threshold1Utra = - 130 dBm threshold2GERAN = -140 dBm b2Threshold1GERAN = -75 dBm b2Threshold2UtraEcn0 = -14 dB b2Threshold2UtraRscp = -110 dBm To 3G A3 event threshold2InterFreq = -116 dBm a3OffsetRsrpInterFreq = 3 dB A5 event threshold3Interfreq = -115 dBm threshold3aInterfreq = -114 dBm A3 event threshold2InterFreq = -112 dBm a3OffsetRsrpInterFreq = 3 dB A5 event threshold3Interfreq = -115 dBm threshold3aInterfreq = -114 dBm A3 event threshold2InterFreq = -140 dBm a3OffsetRsrpInterFreq = 3 dB A5 event threshold3Interfreq = -115 dBm threshold3aInterfreq = -114 dBm threshold4 = -120 dBm (Priority = L800) threshold2MobRsrq = -17dB threshold4RsRq = -19dB threshold2Wcdma = -130 dBm b2Threshold1Utra = - 130 dBm threshold2GERAN = -140 dBm b2Threshold1GERAN = -75 dBm threshold4 = -116 dBm (Priority = L800) threshold2Wcdma = -130 dBm b2Threshold1Utra = - 130 dBm threshold2GERAN = -140 dBm b2Threshold1GERAN = -75 dBm threshold4 = -124 dBm (Priority = U900) threshold2Wcdma = -120 dBm b2Threshold1Utra = - 120 dBm threshold2GERAN = -140 dBm b2Threshold1GERAN = -75 dBm b2Threshold2RssiGERAN = -100 dBm To 2G
  • 3. Connected Mode – AMLE Load Balancing L800 (10 MHz) – L1 qrxlevmin = -124 dBm L1800 (5 MHz) – L2 L2100 (10 MHz) – L7 qrxlevmin = -120 dBm qrxlevmin = -120 dBm nomNumPrbNonGbr = 0.005 (5) iFLBHighLoadNonGBRDL = 85% L2300 (20 MHz) – L4 qrxlevmin = -124 dBm nomNumPrbNonGbr = 0.1 (100) iFLBHighLoadNonGBRDL = 85% nomNumPrbNonGbr = 0.2 (200) iFLBHighLoadNonGBRDL = 85% nomNumPrbNonGbr = 0.5 (500) iFLBHighLoadNonGBRDL = 85% thresholdRsrpIFLBFilter = -110 dBm thresholdRsrqIFLBFilter = -14 dB maxCacThreshold = 100% deltaCac = 2% thresholdRsrpIFLBFilter = -110 dBm thresholdRsrqIFLBFilter = -14 dB maxCacThreshold = 100% deltaCac = 2% thresholdRsrpIFLBFilter = -110 dBm thresholdRsrqIFLBFilter = -14 dB maxCacThreshold = 100% deltaCac = 2% thresholdRsrpIFLBFilter = -110 dBm thresholdRsrqIFLBFilter = -14 dB maxCacThreshold = 100% deltaCac = 2%
  • 4. Connected Mode – VoLTE L800 (10 MHz) – L1 qrxlevmin = -124 dBm L1800 (5 MHz) – L2 L2100 (10 MHz) – L7 qrxlevmin = -120 dBm qrxlevmin = -120 dBm L2300 (20 MHz) – L4 qrxlevmin = -124 dBm A3 event threshold2InterFreq = -116 dBm a3OffsetRsrpInterFreq = 3 dB A5 event threshold3Interfreq = -115 dBm threshold3aInterfreq = -114 dBm threshold4 = -120 dBm (Priority = L800) threshold2WcdmaQCI1 = -118 dBm b2Threshold1UtraQCI1 = - 75 dBm threshold2GERANQCI1 = -119 dBm b2Threshold2UtraEcn0 = -14 dB b2Threshold2UtraRscp = -110 dBm To 3G A3 event threshold2InterFreqQCI1 = -112 dBm a3OffsetRsrpInterFreq = 3 dB A5 event threshold3Interfreq = -115 dBm threshold3aInterfreq = -114 dBm A3 event threshold2InterFreq = -112 dBm a3OffsetRsrpInterFreq = 3 dB A5 event threshold3Interfreq = -115 dBm threshold3aInterfreq = -114 dBm A3 event threshold2InterFreq = -140 dBm a3OffsetRsrpInterFreq = 3 dB A5 event threshold3Interfreq = -115 dBm threshold3aInterfreq = -114 dBm threshold4 = -120 dBm (Priority = L800) threshold2WcdmaQCI1 = -114 dBm b2Threshold1UtraQCI1 = - 75 dBm threshold2GERANQCI1 = -115 dBm threshold4 = -116 dBm (Priority = L800) threshold2WcdmaQCI1 = -114 dBm b2Threshold1UtraQCI1 = - 75 dBm threshold2GERANQCI1 = -115 dBm threshold4 = -124 dBm (Priority = U900) threshold2WcdmaQCI1 = -118 dBm b2Threshold1UtraQCI1 = - 75 dBm threshold2GERANQCI1 = -119 dBm b2Threshold2RssiGERAN = -100 dBm To 2G