Hi-Tech provides building energy modeling and analysis services. Check the key points of our services below.
1) To qualify the building for EPACT Certification using eQuest.
2) Interior, Exterior & Day Lighting reports for existing & proposed design.
3) Review of existing buildings, HVAC systems, lighting etc. & possibly save up to 60% in the proposed design, better than the Code.
4) Comparison of existing & proposed systems with respect to the Baseline Appendix-G ASHRAE 90.1.
5) Technical assistance to reduce energy consumption as per international standards (i.e. ASHRAE 90.1), local authority regulation & as per client’s requirements.
6) Software Used for Energy Modeling : eQuest 3.64, DiaLux, COMcheck & AutoCAD.
For any queries please email us at info@hitechcaddservices.com
2. Hi-Tech Offerings
Architectural Structural MEP
SERVICES
Mechanica BIM
l
CAE Electrica
l
3. Hi-Tech Clientele – Worldwide
Hi-Tech is a leading engineering services company
for architectural, structural, civil, mechanical and
electrical design, drafting, modeling and animation.
INTERNATIONAL DOMESTIC
4. Energy Modeling & Analysis Services
• Hi-Tech provides Energy Modeling / Simulation & Analysis services.
• To qualify the building for EPACT Certification using eQuest.
• Interior, Exterior & Day Lighting reports for existing & proposed design.
• Review of existing buildings, HVAC systems, lighting etc. & possibly save up to
60% in the proposed design, better than the Code.
• Comparison of existing & proposed systems with respect to the Baseline
Appendix-G ASHRAE 90.1.
• Technical assistance to reduce energy consumption as per international standards
(i.e. ASHRAE 90.1), local authority regulation & as per client’s requirements.
• Software Used for Energy Modeling : eQuest 3.64, DiaLux, COMcheck &
AutoCAD.
SERVICES
Energy Analysis Light Pollution Analysis
Fenestration Analysis Reflection & Glare Analysis
Solar Insolation Analysis Shadow Analysis
Day Light Analysis Visibility Analysis
Location Analysis Acoustic Analysis
5. Energy Modeling Projects
Artificial Lighting Modeling
& Simulation
Client
Lighting Company in UK
Scope of Work
Energy Modeling, Analysis for efficient
artificial lighting
Inputs
2D Drawings in PDF format.
Details of Luminaries and fixtures
Output
3D Model
Energy Simulation and Analysis
Energy Consumption Data
The above mentioned modeling, analysis
were done based on the electrical design
and data provided by the client.
The fixtures and luminaries were selected
as per client’s suggestion
Software Relux | Team 02 | Duration 03 Days
6. Energy Modeling Projects
Natural Day Lighting
Modeling & Analysis of
Daylight Factor and Lux
Levels
Client
An Architect Firm in United States
Scope of Work
Energy Modeling, Analysis for calculating
the natural day light available in the
classroom of the school building. The
analysis was done at two times of day
and three times of the year
Inputs
2D Drawings in PDF format.
Details of Building Envelope and Material
Output
3D Model
Energy Simulation and Analysis.
Of Daylight available
The above mentioned modeling, analysis
were done based on the geographical
location, design data provided by the
client
Software Ecotect | Team 01 | Duration 12 Days
7. Energy Modeling Projects
Shadow Analysis for the
Buildings
Client
A Property Development Company in
Australia
Scope of Work
Creating the 3D model using BIM
software and calculating the shadow path
based on the geographical situation of
the building and the sun path
Inputs
2D Drawings in PDF format.
Geographical location
Output
3D Model
Animation of shadow path during the
particular time of the day
Software Revit | Team 01 | Duration 01 Day
8. Energy Modeling in
Departmental Store eQuest 3.64
Project Type: Departmental Store in
USA
Scope of Work:
1. To compare Baseline building as per
ASHRAE 90.1 Appendix G to Proposed
Building & Existing building
performance.
2. To Propose efficient HVAC systems for
Proposed design
3. To qualify Building for EPACT
certification
Inputs
1. Existing & proposed CAD
Civil, Mechanical & Electrical layouts
2. Comchech Report comparing lighting.
3. Building Usage Information
4. Existing building Utility Bills
Output
1. Monthly & Annual Energy
Consumption by End use
2. Monthly Utility Bills
3. Monthly & annual Peak demand by
End use
4. Monthly Electric Peak Day load
Profiles
Software eQuest 3.64 | Team 1 | Duration 5 Days
9. Lighting Analysis
Departmental Store
Project Type: Departmental Store in USA
Inputs
Site Photos.
PDF of Tentative Architectural Layout of
Interior & Exterior.
Output
Tentative CAD Architectural Layout.
Foot Candle Analysis of Existing Interior &
Exterior Lighting Design.
CAD Layout of Existing Lighting Design.
Compliance Report of Existing Lighting
System i.e. As per ASHARE 90.1, IECC etc.
Foot Candle Analysis of Proposed Interior
& Exterior Lighting Design.
CAD Layout of Proposed Lighting Design.
Compliance Report of Proposed Lighting
System i.e. As per ASHARE 90.1, IECC etc.
Software DiaLux & ComCheck | Team 1 | Duration 5 Days
10. Energy Modeling in
Dining Facility eQuest 3.64
Project Type: Dining Facility in USA
Scope of Work:
1. To compare Baseline building as per
ASHRAE 90.1 Appendix G to
Proposed Building & Existing building
performance.
2. To Propose efficient HVAC systems
for Proposed design
3. To qualify Building for EPACT
certification
Inputs
1. Existing & proposed CAD
Civil, Mechanical & Electrical layouts
2. Comchech Report comparing lighting.
3. Building Usage Information
4. Existing building Utility Bills
Output
1. Monthly & Annual Energy
Consumption by End use
2. Monthly Utility Bills
3. Monthly & annual Peak demand by
End use
4. Monthly Electric Peak Day load
Profiles
Software eQuest 3.64 | Team 1 | Duration 5 Days
11. Lighting Analysis
Dining Facility
Project Type: Dining Facility in USA
Inputs
Architectural Layout.
Existing Lighting PDF Layout.
Output
Foot Candle Analysis of Existing Interior
Lighting Design.
CAD Layout of Existing Lighting Design.
Compliance Report of Existing Lighting
System i.e. As per ASHARE 90.1, IECC etc.
Foot Candle Analysis of Proposed Interior
Lighting Design.
CAD Layout of Proposed Lighting Design.
Compliance Report of Proposed Lighting
System i.e. As per ASHARE 90.1, IECC etc.
Software DiaLux & ComCheck | Team 1 | Duration 5 Days
12. Lighting Analysis
Dining Facility
Project Type: Dining Facility in USA
Inputs
Site Location.
Door & Window Schedule.
Output
Day Light Calculation.
Software DiaLux & ComCheck | Team 1 | Duration 5 Days
13. Energy Modeling in
Dining Facility eQuest 3.64
Project Type: Dining Facility in USA
Scope of Work:
1. To compare Baseline building as per
ASHRAE 90.1 Appendix G to
Proposed Building & Existing building
performance.
2. To Propose efficient HVAC systems
for Proposed design
3. To qualify Building for EPACT
certification
Inputs
1. Existing & proposed CAD
Civil, Mechanical & Electrical layouts
2. Comchech Report comparing lighting.
3. Building Usage Information
4. Existing building Utility Bills
Output
1. Monthly & Annual Energy
Consumption by End use
2. Monthly Utility Bills
3. Monthly & annual Peak demand by
End use
4. Monthly Electric Peak Day load
Profiles
Software eQuest 3.64 | Team 1 | Duration 5 Days
14. Lighting Analysis
Dining Facility
Project Type: Dining Facility in USA
Inputs
Architectural Layout.
Existing Lighting PDF Layout.
Output
Foot Candle Analysis of Existing Interior
Lighting Design.
CAD Layout of Existing Lighting Design.
Compliance Report of Existing Lighting
System i.e. As per ASHARE 90.1, IECC etc.
Foot Candle Analysis of Proposed Interior
Lighting Design.
CAD Layout of Proposed Lighting Design.
Compliance Report of Existing Lighting
System i.e. As per ASHARE 90.1, IECC etc.
Software DiaLux & ComCheck | Team 1 | Duration 5 Days
15. Lighting Analysis
Dining Facility
Project Type: Dining Facility in USA
Inputs
Site Location.
Door & Window Schedule.
Output
Day Light Calculation.
Software DiaLux | Team 1 | Duration 2 Days
16. Energy Modeling in
Commercial Building eQuest 3.64
Project Type: Commercial building in USA
Scope of Work:
1. To compare Baseline building as per
ASHRAE 90.1 Appendix G to Proposed
Building & Existing building
performance.
2. To Propose efficient HVAC systems for
Proposed design
3. To qualify Building for EPACT
certification
Inputs
1. Existing & proposed CAD
Civil, Mechanical & Electrical layouts
2. Comchech Report comparing lighting.
3. Building Usage Information
4. Existing building Utility Bills
Output
1. Monthly & Annual Energy Consumption
by End use
2. Monthly Utility Bills
3. Monthly & annual Peak demand by End
use
4. Monthly Electric Peak Day load Profiles
Software eQuest 3.64 | Team 1 | Duration 5 Days
17. Lighting Analysis
Commercial Building
Project Type: Commercial Building in USA
Inputs
Architectural Layout.
Existing Lighting PDF Layout.
Output
Foot Candle Analysis of Existing Interior
Lighting Design.
CAD Layout of Existing Lighting Design.
Compliance Report of Existing Lighting
System i.e. As per ASHARE 90.1, IECC etc.
Foot Candle Analysis of Proposed Interior
Lighting Design.
CAD Layout of Proposed Lighting Design.
Compliance Report of Existing Lighting
System i.e. As per ASHARE 90.1, IECC etc.
Software DiaLux & ComCheck | Team 1 | Duration 5 Days
18. Lighting Analysis
Commercial Building
Project Type: Commercial Building in
USA
Inputs
Site Location.
Door & Window Schedule.
Output
Day Light Calculation.
Software DiaLux | Team 1 | Duration 2 Days
19. Energy Modeling in
Office Building eQuest 3.64
Project Type: Office Building in USA
Scope of Work:
1. To compare Baseline building as per
ASHRAE 90.1 Appendix G to Proposed
Building & Existing building
performance.
2. To Propose efficient HVAC systems for
Proposed design
3. To qualify Building for EPACT
certification
Inputs
1. Existing & Proposed CAD
Civil, Mechanical & Electrical layouts
2. Comchech Report comparing lighting
3. Building Usage Information
4. Existing building Utility Bills
Output
1. Monthly & Annual Energy Consumption
by End use
2. Monthly Utility Bills
3. Monthly & annual Peak demand by End
use
4. Monthly Electric Peak Day load Profiles
Software eQuest 3.64 | Team 1 | Duration 5 Days
20. Energy Modeling in
Warehouse Building eQuest 3.64
Project Type : Warehouse building in USA
Scope of Work:
1. To compare Baseline building as per
ASHRAE 90.1 Appendix G to Proposed
Building & Existing building performance.
2. To Propose efficient HVAC systems for
Proposed design
3. To qualify Building for EPACT
certification
Inputs
1. Existing & Proposed CAD
Civil, Mechanical & Electrical layouts
2. Comchech Report comparing lighting.
3. Building Usage Information
4. Existing building Utility Bills
Output
1. Monthly & Annual Energy Consumption
by End use
2. Monthly Utility Bills
3. Monthly & annual Peak demand by End
use
4. Monthly Electric Peak Day load Profiles
Software eQuest 3.64 | Team 1 | Duration 5 Days
21. Energy Modeling in
Industrial Building eQuest 3.64
Project Type : Industrial Building in
USA
Scope of Work:
1. To compare Baseline building as per
ASHRAE 90.1 Appendix G to
Proposed Building & Existing building
performance.
2. To Propose efficient HVAC systems
for Proposed design
3. To qualify Building for EPACT
certification
Inputs
1. Existing & Proposed CAD
Civil, Mechanical & Electrical layouts
2. Comchech Report comparing lighting.
3. Building Usage Information
4. Existing building Utility Bills
Output
1. Monthly & Annual Energy
Consumption by End use
2. Monthly Utility Bills
3. Monthly & annual Peak demand by
End use
4. Monthly Electric Peak Day load
Profiles
Software eQuest 3.64 | Team 1 | Duration 5 Days