1. AMIT SELADIYA
Mo No +919510099610
http/linkedin.com/ amit-seladiya-55621762
POST APPLIED: Analyzer Service Engineer.
SUMMARY ______________________________________________________________
I have good technical background of Analyzer in Oil & Gas Refinery field. More than 06
'years’ Experience in Analyzer, worked during construction, commissioning, start-up and
Maintenance in many different Oil & Gas Refinery.
GULF EXPERIENCE _______________________________________________________
QATAR(RAS GAS)
“RAS GAS” inQATAR Analyzershutdownjobsthrough QNFS.
Duration : -03 Feb2016 t0 02 Mar 2016.
Position : - AnalyzerER.
SAUDI ARABIA (PETRO RABIGH)
“PETRO RABIGH” refineryin SAUDIARABIA AnalyzerOverhaul jobsthrough YOKOGAVAMIDDEL
EAST.
Duration : - 27 Sep2015 to 26 Des2015.
Position : - AnalyzerMNT Specialist.
UAEABU-DHABI (GASCO)
“GASCO” refineryin UAEAnalyzerproject Commissioningworkthrough AIMS(VenderComp).
Duration : - 13 Mar 2013 to 12 Mar 2014.
Position : - AnalyzerMNT/CommissioningER.
INDIA INEXPERIENCE:
RELIANCE OIL &GASREFINARY through Hofincons.
Duration: 06 Jun 2009 to 28 Feb2013 and 12/03/2014 to 25/09/2015.
2. EDUCATION ________________________________________________________
DEPLOMA, INSTRUMENT (IC) Christ Polytechnics.
INDUSTRIAL TRAINING INSTITUTE- Rajkot, Gujarat, India.
SSC-ENGLISH.GSEB, GANDHINAGAR- Rajkot, Gujarat, India.
Hocasnel Training. Gujarat State Fertilizers Chemicals.(GSFC).
JOB DESCRIPTION ________________________________________________________
Analyzers sample conditioningsystemroutinemaintenancesuchaspumps,valves,actuator,flow
mitermembranesfilter,aovetc.
SIEMEANSGCin alsocline model 50 valve and replace diaphragm.
ABB GCinalso maintenance liv–replacesslidoaringandColumswitchingvalve cline and
replace Columslide.
GC Knowledge for Peak Cutting-back flush, hart cut, diverter.
GC inAll flowchecksandadjust(backflush,selective vent,makeupgas,detectorventetc) a
standarddatasheetwise.
SRU PLANIN AMETEK 919 SO2/O2, 900 AIR DEMAND analyzerinalsoreplace cadmium,
magnesium lamp,cleanedcell,mirrorandreplaced celloaring,choppermotor,beltandwheel
barringfaultycards and de chock samplingline, analyzeralsotakeninbackpurgingmode and
span andzero gas calibrationandautosetup.
AMETEK suppliedflue gas O2/COanalyzerinalsocheck andreplace faultycardszirconium
sensor,thermocouple,furnishsamplesuctionsidefilter, COsensoretc.
POLY PROPYLINE planinscandal wise cycle gascompressorfromPSHSinblow bakeworkand
cline Mottfilter.
Preventive Maintenance (Calibration) of AnalyzersandUpdate the calibration sheets.
Maintaininga (FID) Flame Ionization DetectorCorrective maintenance of AnalyzersandReplace
the faultysensors,card
DailyInspectMaintenance of On-Line AnalyzersandSamplingSystemsincludingtrouble
shootingof failuresvalidationandcalibrationtoretain infunctional andgood operatingorder
for reliable performance.Ionof All AnalyzersSample PointPressure,Flow,andTemperature.
Replace the careergas and calibrationcylindersforGCand otherAnalyzers.
Breakdownjobs(EmergencyJobsDuringPlantRunning)
ShutdownandTurnaroundactivitiessuchasisolationof all sample points,overhaul GC
Analyzers,Replacethe filtersinprimaryandsecondarysamplingboxes,Inspectionandcleaning
of sample probes, checkandreplacedHPR.
PM Job,Corrective Maintenance and Troubleshootingof all Analyzer.
Checkand Rectifythe problemof samplingconditioningboxessuchasleak,flow struckup,
replace the micronfilters,checkvaluesandbox temperature problems.
3. Installation&Commissioningof SamplingSystemsof AnalyzerInstrumentssuchasGas
Chromatograph,Moisture andOxygenControllers.
JOB PROFILE: ________________________________________________________
Also Pre-commissioning activities such as loops and logics checks and troubleshooting.
Doing the preventive, breakdown and troubleshooting jobs on following analyzers.
ABB supplied vista 2000 series Gas Chromatograph.
SIEMENS Maxum edition 2 Gas Chromatograph.
AMETEK 919 SO2/O2 Stack Analyzer.
AIR DEMAND 900 H2S/S02 Analyzer
AMETEK 930 Feed Gas (H2S) Analyzer.
AMETEK supplied flue gas O2/CO Analyzer.
FOXBORO, Rosemount, polymetron supplied pH Analyzer.
Maintenance of Sample Condition System.
Sick mahick sox/nox Analyzer.
AMETEK 3050, 5000 series moisture Analyzer.
AMETEK LAB ANALYZERS MODEL NO 2, 3 and 4 LANCOM analyzer.
ROSEMOUNT O2 Zirconium analyzer.
LANGUAGES _____________________________________________________
English, Hindi, Guajarati.
SUMMARY ______________________________________________
A Process Analyzer Professional detailed knowledge and my experience of process and
environmental analytical systems in all aspects.
Working Poly Propylene, Sulphur recovery plants, Cocker and Aromatics Plans.
My Experience in All parts of analytical system starting from sample probe and up to
sample disposal and going through sample oning, transport, conditioning then the
analyzer and communication with control system.
Range of analyzer/analytical system components manufacturers and system integrators
Knowledge. Knowles in Specification, Maintenance and operation of Analyzer Houses,
shelters, cabinets and all associated safety monitoring and HVAC systems.
Range of analytical methods and techniques knowledge Chromatography, spectroscopy,
electrochemical cells, paramagnetic, TCD, FID, FPD.
Knowles combustible and toxic gas detectors, fire & gas detection systems and Fire
suppression systems.
Specialties: Process Analytical systems specification, design, installation,
commissioning, start‐up
4. SKILLS &TRAINING _____________________________________________
Analyzers sample conditioning system routine maintenance such as pumps, valves, actuator,
flow miter membranes filter, aov etc.
SIEMEANS GC in also cline model 50 valve and Replace diaphragm.
ABB GC in maintenance liv –replaces slid oaring and Colum switching valve cline and replace
Colum slide. Permit TO work system
HIRA (Hazard Identification &Risk Assessment)
Experienced with highlyadvanced analyzers which are versatile for advanced automated process control,
environmental control and vital functions in the industries like Refineries,Petro-Chemicals,Offshore
production companies,LNG& Gas production companies
Able to recognize the cause of failure in analyzer systems,analyzer houses,troubleshooting ofprocess
analyzers & GC's, sample conditioning systems,analyzer system functions via extraction, transportline and
automatic switching control system through analyzer output.
Leadership and Team Building Skills.
Excellent knowledge aboutPermitto work systems (PTW) and several kinds of permits like Cold work
permit,Hot work permit,Confined Space Entry permits etc.
Excellent organizational,interpersonal and team-working skills which include reportwriting,formal
presentations and the ability to work with a wide range of personnel from a multi-cultural and multi-functional
environment.A flexible, individual as well as a team player.
Good knowledge and Hand on experience on analyzers having measuring techniques like
chemiluminescence,thermal conductivity, flame ionization detectors,multiwave photometer, flame
photometric detectors,ultra violet absorption,multi wave,paramagnetic and zirconium detectors.
HSE knowledge as required with in the Oil & Gas industry.
Well-versed on design ofsample conditioning systems for analyzers and GC's, supervision of analyzer
house manufacturing & system integration,sample recoverysystems,analyzer shelters,racks & cabinets
and demonstration ofFactory Acceptance Test(FAT) program for analyzer house packages suitable for
hazardous as well as safe area.
TRAINING ___________________________________________________
Three day work shop in Reliance Oil and Gas.
Confined Space Attended in Reliance Oil and Gas.
One Day Workshop Safety in Reliance Oil and Gas.
Fire Watch in Reliance Oil and Gas.
H2SEBA in Ras Gas – QATAR.
ISI in Ras Gas – QATAR.
G Rules in Ras Gas – QATAR.
WM Systems in Ras Gas – QATAR.
SSI in Ras Gas – QATAR.
W@Heights in Ras Gas – QATAR.
Permit TO work system in Ras Gas – QATAR.
HIRA (Hazard Identification &Risk Assessment) in Ras Gas – QATAR.
5. Passport Details _________________________________________
Passport No. : K 6055177
Date of Issue : 25/07/2012
Date of Expiry : 24/07/2022
Place of Issue : Ahmadabad, Gujarat.
PERSONAL DETAILS ___________________________________________
NAME: Amit M Seladiya.
ADRES: Shraddha soc, SR no 05, Bapa Sitaram Chock,Rajkor,360002-Gujarat (INDIA).
Marital Status: Married.
Citizenship: India.
Date of Birth: 22 Nov. 1990.
Sex: Male.
Mo Number: +919510099610 (WhatsApp)
Email: seladiyaamit@yahoo.in
Skype: amit.seladiya
Linked: http/linkedin.com/ amit-seladiya-55621762.