HIGH VOLTAGE
MANAGEMENT IN
COMMUNICATION
ENGINEERING
INTRODUCTION
Fast-growing network demands are placing ever-greater strain on the advanced communications
systems that increasingly support voice, video and data transmissions. What’s more, deployment of
electronics further into the network has resulted in miniaturization (and higher integration density),
which means reduced electrical strength of components. Both of these trends may result in greater
risk of overvoltage and overcurrent, making overvoltage protection significantly more important over
the past years
OVER
VOLTAGE
3
1
2
4
5
FAULTS
Overvoltage is the
primary cause of faults
in communication
systems
LOSSES
Overvoltage in centrally
controlled processes
can cause losses worth
of millions of dollars
CAUSES
Overvoltage in
communication is
mainly caused by
electromagnetic
interference
LIGHTNIN
G
Lightning can cause
overvoltage surge in
communication lines
located kilometres
away
STATIC
CHARGES
seemingly
harmless static
discharges can
paralyze entire
networks
DEMAND
Fast-growing network
demands are placing
ever-greater strain on
the advanced
communications
systems
DAMAGE
High Voltage through
the communication
lines can damage
equipment and lead
to major losses
NECESSITY
USAGE
Deployment of
electronics further
into the network has
resulted in
miniaturization
COST
It is cheaper to install
protective measures
to mitigate high
voltage surge than
replacing damaged
equipment
1
2 4
3 5
6
INTERFERENCE
LIGHTNING
STRIKES
INDIRECT
LIGHTNING
IMPACT
ELECTROMAGNE
TIC
INTERFERENCE
ELECTROSTAT
IC DISCHARGE
INDUCTIVE &
CAPACITIVE
EFFECTS
CONTACT
WITH LIVE
POWER LINES
1
2
3
4
5
PROTECTION MEASURES
Overvoltage protection devices consist of components
or protective circuits that limit interference to permissible
values
Overvoltage protection devices must be adapted to
regional and local requirements.
Graded protective circuits with secondary protection
elements should be used for incoming circuits on the
exchange side and for terminal equipment (telephone,
fax, modem)
If active components are
installed in a cross-connection cabinet, graded
protective circuits are also recommended.
Requirements include operating
conditions on the line and protection requirements that
result from the specific application area.
OPERATING VOLTAGE
The operating voltage of the system to be protected
determines the protection plug’s voltage class. The
protection device must not be triggered during normal
operation as this would not only destroy the protective
circuit, but would also lead to interruption in signal
transmission.
The highest possible voltage class should be selected
for the protection plug – at least above the maximum
voltage possible during operation (maximum operating
voltage including tolerance). The upper limit for selecting
the protection plug’s voltage class is determined by the
maximum protection level permitted (the maximum input
voltage that would not damage the downstream system
components should overvoltage occur). The selection of
components and switching configurations determines other
electrical parameters for protective circuits. Properly
designed and specified overvoltage protection components
have a serviceable life of several decades and require no
additional maintenance. CommScope recommends that the
nominal DC spark-over voltage of installed protection
components be tested regularly. For safety reasons, the
arrestors should be replaced if the protective circuit has
been subjected to impulse current.
SELECTION
Regardless of the series and circuit used, all
overvoltage protection components rely on the same
working principle: excessive voltages are discharged to
earth. Depending on the component, the energy
consumption of the protection device is relatively low.
One precondition for this is the protection component’s
low-resistance earthing. In line with signal potentials, a
distinction is made between three-point and five-point
protection. For connection modules, only three-point
protection is possible. Five-point protection
(components in the signal path) is recommended for
use with switching modules. Once the protective plug
is removed, the contact in the module is open and
possible faults cannot make their way to the
downstream network. Five-point protection can also be
implemented using disconnection modules.
OPERATING CONDITIONS
Protection system design needs to meet the requirements of copper-based connection and distribution systems.
In most applications, the protection modules are electrically
equivalent; however, their contact and protection behaviour is not necessarily compatible
Basic differentiators include:
• Operating behaviour of the system to be protected
• Overvoltage protection requirements (electrical and
mechanical), for example requirements facing the
permissible impulse current or the permissible AC
discharge current. The network operator’s
specifications must be observed when designing
the protection modules.
• Requirements for protection for a single pair, or
an entire module
COST BENEFIT
When selecting overvoltage protection
modules, the cost to-benefit ratio is
key. The cost of installing protection
modules is clearly offset by the increased
availability of the communication network
and lower repair costs. By carefully
selecting equipment, network operators
can minimize costs while realizing
maximum economic efficiency of
equipment.
The extent of protection measures is
based on requirements and specifications
from the network operator or equipment
manufacturer. To protect personnel,
applicable standards and regulations for
setting up and operating
telecommunications
networks must also be observed.

Weitere ähnliche Inhalte

Ähnlich wie Communication eng.pptx

Jmv presentation smart power transmission projects cea
Jmv  presentation  smart power transmission projects  ceaJmv  presentation  smart power transmission projects  cea
Jmv presentation smart power transmission projects ceaMahesh Chandra Manav
 
Best Practices for Lightning Protection on Automatic Transfer Switches
Best Practices for Lightning Protection on Automatic Transfer SwitchesBest Practices for Lightning Protection on Automatic Transfer Switches
Best Practices for Lightning Protection on Automatic Transfer SwitchesPetro Guardian
 
Jmv presentation smart process plant -hurl 2017
Jmv  presentation  smart process plant -hurl 2017Jmv  presentation  smart process plant -hurl 2017
Jmv presentation smart process plant -hurl 2017Mahesh Chandra Manav
 
Surge_Protection_Device_for_Solar_PV_Application
Surge_Protection_Device_for_Solar_PV_ApplicationSurge_Protection_Device_for_Solar_PV_Application
Surge_Protection_Device_for_Solar_PV_ApplicationAllied Power APS
 
protectionsettings-120425102109-phpapp01.ppt
protectionsettings-120425102109-phpapp01.pptprotectionsettings-120425102109-phpapp01.ppt
protectionsettings-120425102109-phpapp01.pptThien Phan Bản
 
protectionsettings-120425102109-phpapp01.ppt
protectionsettings-120425102109-phpapp01.pptprotectionsettings-120425102109-phpapp01.ppt
protectionsettings-120425102109-phpapp01.pptThien Phan Bản
 
Power quality presentation by jmv lps
Power quality presentation by jmv lpsPower quality presentation by jmv lps
Power quality presentation by jmv lpsMahesh Chandra Manav
 
Smart Grid Overvoltage Protection
Smart Grid Overvoltage ProtectionSmart Grid Overvoltage Protection
Smart Grid Overvoltage ProtectionMike Nager
 
Transformer Protection using PLC
Transformer Protection using PLCTransformer Protection using PLC
Transformer Protection using PLCSageer Ali Khan
 
Fault analysis in power system using power systems computer aided design
Fault analysis in power system using power systems computer aided designFault analysis in power system using power systems computer aided design
Fault analysis in power system using power systems computer aided designIJAAS Team
 
GIS substation Information (Detailed Report)
GIS substation Information (Detailed Report)GIS substation Information (Detailed Report)
GIS substation Information (Detailed Report)siddharth sharma
 
Building Automation,Networking & Communication Presentation by LVS 2022.pdf
Building Automation,Networking & Communication Presentation by LVS 2022.pdfBuilding Automation,Networking & Communication Presentation by LVS 2022.pdf
Building Automation,Networking & Communication Presentation by LVS 2022.pdfMahesh Chandra Manav
 
Modelling and Implementation of Microprocessor Based Numerical Relay for Prot...
Modelling and Implementation of Microprocessor Based Numerical Relay for Prot...Modelling and Implementation of Microprocessor Based Numerical Relay for Prot...
Modelling and Implementation of Microprocessor Based Numerical Relay for Prot...Kashif Mehmood
 
Link vue system and solar pv power plant protection
Link vue system and solar pv power plant protectionLink vue system and solar pv power plant protection
Link vue system and solar pv power plant protectionMahesh Chandra Manav
 
Power System Protection
Power System ProtectionPower System Protection
Power System ProtectionRahul Mehra
 
Power transmission and distribution along with power qualty presentation by j...
Power transmission and distribution along with power qualty presentation by j...Power transmission and distribution along with power qualty presentation by j...
Power transmission and distribution along with power qualty presentation by j...Mahesh Chandra Manav
 
Overview lvrt capability of dfig techniques
Overview lvrt capability of dfig techniquesOverview lvrt capability of dfig techniques
Overview lvrt capability of dfig techniquesIAEME Publication
 
Protecting the wind energy system from a short circuit (requirements - challe...
Protecting the wind energy system from a short circuit (requirements - challe...Protecting the wind energy system from a short circuit (requirements - challe...
Protecting the wind energy system from a short circuit (requirements - challe...IRJET Journal
 
Ipsa mv relay co-ordiantion shaik adam
Ipsa  mv relay  co-ordiantion shaik adamIpsa  mv relay  co-ordiantion shaik adam
Ipsa mv relay co-ordiantion shaik adamShaik Abdullah Adam
 

Ähnlich wie Communication eng.pptx (20)

Jmv presentation smart power transmission projects cea
Jmv  presentation  smart power transmission projects  ceaJmv  presentation  smart power transmission projects  cea
Jmv presentation smart power transmission projects cea
 
EMC for Networks - Peter Thomas, Control Specialists and Jos Knockaert, UGent
EMC for Networks - Peter Thomas, Control Specialists and Jos Knockaert, UGentEMC for Networks - Peter Thomas, Control Specialists and Jos Knockaert, UGent
EMC for Networks - Peter Thomas, Control Specialists and Jos Knockaert, UGent
 
Best Practices for Lightning Protection on Automatic Transfer Switches
Best Practices for Lightning Protection on Automatic Transfer SwitchesBest Practices for Lightning Protection on Automatic Transfer Switches
Best Practices for Lightning Protection on Automatic Transfer Switches
 
Jmv presentation smart process plant -hurl 2017
Jmv  presentation  smart process plant -hurl 2017Jmv  presentation  smart process plant -hurl 2017
Jmv presentation smart process plant -hurl 2017
 
Surge_Protection_Device_for_Solar_PV_Application
Surge_Protection_Device_for_Solar_PV_ApplicationSurge_Protection_Device_for_Solar_PV_Application
Surge_Protection_Device_for_Solar_PV_Application
 
protectionsettings-120425102109-phpapp01.ppt
protectionsettings-120425102109-phpapp01.pptprotectionsettings-120425102109-phpapp01.ppt
protectionsettings-120425102109-phpapp01.ppt
 
protectionsettings-120425102109-phpapp01.ppt
protectionsettings-120425102109-phpapp01.pptprotectionsettings-120425102109-phpapp01.ppt
protectionsettings-120425102109-phpapp01.ppt
 
Power quality presentation by jmv lps
Power quality presentation by jmv lpsPower quality presentation by jmv lps
Power quality presentation by jmv lps
 
Smart Grid Overvoltage Protection
Smart Grid Overvoltage ProtectionSmart Grid Overvoltage Protection
Smart Grid Overvoltage Protection
 
Transformer Protection using PLC
Transformer Protection using PLCTransformer Protection using PLC
Transformer Protection using PLC
 
Fault analysis in power system using power systems computer aided design
Fault analysis in power system using power systems computer aided designFault analysis in power system using power systems computer aided design
Fault analysis in power system using power systems computer aided design
 
GIS substation Information (Detailed Report)
GIS substation Information (Detailed Report)GIS substation Information (Detailed Report)
GIS substation Information (Detailed Report)
 
Building Automation,Networking & Communication Presentation by LVS 2022.pdf
Building Automation,Networking & Communication Presentation by LVS 2022.pdfBuilding Automation,Networking & Communication Presentation by LVS 2022.pdf
Building Automation,Networking & Communication Presentation by LVS 2022.pdf
 
Modelling and Implementation of Microprocessor Based Numerical Relay for Prot...
Modelling and Implementation of Microprocessor Based Numerical Relay for Prot...Modelling and Implementation of Microprocessor Based Numerical Relay for Prot...
Modelling and Implementation of Microprocessor Based Numerical Relay for Prot...
 
Link vue system and solar pv power plant protection
Link vue system and solar pv power plant protectionLink vue system and solar pv power plant protection
Link vue system and solar pv power plant protection
 
Power System Protection
Power System ProtectionPower System Protection
Power System Protection
 
Power transmission and distribution along with power qualty presentation by j...
Power transmission and distribution along with power qualty presentation by j...Power transmission and distribution along with power qualty presentation by j...
Power transmission and distribution along with power qualty presentation by j...
 
Overview lvrt capability of dfig techniques
Overview lvrt capability of dfig techniquesOverview lvrt capability of dfig techniques
Overview lvrt capability of dfig techniques
 
Protecting the wind energy system from a short circuit (requirements - challe...
Protecting the wind energy system from a short circuit (requirements - challe...Protecting the wind energy system from a short circuit (requirements - challe...
Protecting the wind energy system from a short circuit (requirements - challe...
 
Ipsa mv relay co-ordiantion shaik adam
Ipsa  mv relay  co-ordiantion shaik adamIpsa  mv relay  co-ordiantion shaik adam
Ipsa mv relay co-ordiantion shaik adam
 

Kürzlich hochgeladen

Call Girls Wakad Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Wakad Call Me 7737669865 Budget Friendly No Advance BookingCall Girls Wakad Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Wakad Call Me 7737669865 Budget Friendly No Advance Bookingroncy bisnoi
 
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...SUHANI PANDEY
 
Unit 1 - Soil Classification and Compaction.pdf
Unit 1 - Soil Classification and Compaction.pdfUnit 1 - Soil Classification and Compaction.pdf
Unit 1 - Soil Classification and Compaction.pdfRagavanV2
 
chapter 5.pptx: drainage and irrigation engineering
chapter 5.pptx: drainage and irrigation engineeringchapter 5.pptx: drainage and irrigation engineering
chapter 5.pptx: drainage and irrigation engineeringmulugeta48
 
Hostel management system project report..pdf
Hostel management system project report..pdfHostel management system project report..pdf
Hostel management system project report..pdfKamal Acharya
 
Minimum and Maximum Modes of microprocessor 8086
Minimum and Maximum Modes of microprocessor 8086Minimum and Maximum Modes of microprocessor 8086
Minimum and Maximum Modes of microprocessor 8086anil_gaur
 
Introduction to Serverless with AWS Lambda
Introduction to Serverless with AWS LambdaIntroduction to Serverless with AWS Lambda
Introduction to Serverless with AWS LambdaOmar Fathy
 
COST-EFFETIVE and Energy Efficient BUILDINGS ptx
COST-EFFETIVE  and Energy Efficient BUILDINGS ptxCOST-EFFETIVE  and Energy Efficient BUILDINGS ptx
COST-EFFETIVE and Energy Efficient BUILDINGS ptxJIT KUMAR GUPTA
 
Unleashing the Power of the SORA AI lastest leap
Unleashing the Power of the SORA AI lastest leapUnleashing the Power of the SORA AI lastest leap
Unleashing the Power of the SORA AI lastest leapRishantSharmaFr
 
KubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghlyKubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghlysanyuktamishra911
 
Block diagram reduction techniques in control systems.ppt
Block diagram reduction techniques in control systems.pptBlock diagram reduction techniques in control systems.ppt
Block diagram reduction techniques in control systems.pptNANDHAKUMARA10
 
Thermal Engineering Unit - I & II . ppt
Thermal Engineering  Unit - I & II . pptThermal Engineering  Unit - I & II . ppt
Thermal Engineering Unit - I & II . pptDineshKumar4165
 
Employee leave management system project.
Employee leave management system project.Employee leave management system project.
Employee leave management system project.Kamal Acharya
 
Bhosari ( Call Girls ) Pune 6297143586 Hot Model With Sexy Bhabi Ready For ...
Bhosari ( Call Girls ) Pune  6297143586  Hot Model With Sexy Bhabi Ready For ...Bhosari ( Call Girls ) Pune  6297143586  Hot Model With Sexy Bhabi Ready For ...
Bhosari ( Call Girls ) Pune 6297143586 Hot Model With Sexy Bhabi Ready For ...tanu pandey
 
UNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its PerformanceUNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its Performancesivaprakash250
 
Thermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - VThermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - VDineshKumar4165
 

Kürzlich hochgeladen (20)

Call Girls Wakad Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Wakad Call Me 7737669865 Budget Friendly No Advance BookingCall Girls Wakad Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Wakad Call Me 7737669865 Budget Friendly No Advance Booking
 
(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7
(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7
(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7
 
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...
 
Unit 1 - Soil Classification and Compaction.pdf
Unit 1 - Soil Classification and Compaction.pdfUnit 1 - Soil Classification and Compaction.pdf
Unit 1 - Soil Classification and Compaction.pdf
 
chapter 5.pptx: drainage and irrigation engineering
chapter 5.pptx: drainage and irrigation engineeringchapter 5.pptx: drainage and irrigation engineering
chapter 5.pptx: drainage and irrigation engineering
 
Hostel management system project report..pdf
Hostel management system project report..pdfHostel management system project report..pdf
Hostel management system project report..pdf
 
Minimum and Maximum Modes of microprocessor 8086
Minimum and Maximum Modes of microprocessor 8086Minimum and Maximum Modes of microprocessor 8086
Minimum and Maximum Modes of microprocessor 8086
 
Introduction to Serverless with AWS Lambda
Introduction to Serverless with AWS LambdaIntroduction to Serverless with AWS Lambda
Introduction to Serverless with AWS Lambda
 
Call Girls in Netaji Nagar, Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
Call Girls in Netaji Nagar, Delhi 💯 Call Us 🔝9953056974 🔝 Escort ServiceCall Girls in Netaji Nagar, Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
Call Girls in Netaji Nagar, Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
 
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
 
Call Girls in Ramesh Nagar Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
Call Girls in Ramesh Nagar Delhi 💯 Call Us 🔝9953056974 🔝 Escort ServiceCall Girls in Ramesh Nagar Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
Call Girls in Ramesh Nagar Delhi 💯 Call Us 🔝9953056974 🔝 Escort Service
 
COST-EFFETIVE and Energy Efficient BUILDINGS ptx
COST-EFFETIVE  and Energy Efficient BUILDINGS ptxCOST-EFFETIVE  and Energy Efficient BUILDINGS ptx
COST-EFFETIVE and Energy Efficient BUILDINGS ptx
 
Unleashing the Power of the SORA AI lastest leap
Unleashing the Power of the SORA AI lastest leapUnleashing the Power of the SORA AI lastest leap
Unleashing the Power of the SORA AI lastest leap
 
KubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghlyKubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghly
 
Block diagram reduction techniques in control systems.ppt
Block diagram reduction techniques in control systems.pptBlock diagram reduction techniques in control systems.ppt
Block diagram reduction techniques in control systems.ppt
 
Thermal Engineering Unit - I & II . ppt
Thermal Engineering  Unit - I & II . pptThermal Engineering  Unit - I & II . ppt
Thermal Engineering Unit - I & II . ppt
 
Employee leave management system project.
Employee leave management system project.Employee leave management system project.
Employee leave management system project.
 
Bhosari ( Call Girls ) Pune 6297143586 Hot Model With Sexy Bhabi Ready For ...
Bhosari ( Call Girls ) Pune  6297143586  Hot Model With Sexy Bhabi Ready For ...Bhosari ( Call Girls ) Pune  6297143586  Hot Model With Sexy Bhabi Ready For ...
Bhosari ( Call Girls ) Pune 6297143586 Hot Model With Sexy Bhabi Ready For ...
 
UNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its PerformanceUNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its Performance
 
Thermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - VThermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - V
 

Communication eng.pptx

  • 2. INTRODUCTION Fast-growing network demands are placing ever-greater strain on the advanced communications systems that increasingly support voice, video and data transmissions. What’s more, deployment of electronics further into the network has resulted in miniaturization (and higher integration density), which means reduced electrical strength of components. Both of these trends may result in greater risk of overvoltage and overcurrent, making overvoltage protection significantly more important over the past years
  • 3. OVER VOLTAGE 3 1 2 4 5 FAULTS Overvoltage is the primary cause of faults in communication systems LOSSES Overvoltage in centrally controlled processes can cause losses worth of millions of dollars CAUSES Overvoltage in communication is mainly caused by electromagnetic interference LIGHTNIN G Lightning can cause overvoltage surge in communication lines located kilometres away STATIC CHARGES seemingly harmless static discharges can paralyze entire networks
  • 4. DEMAND Fast-growing network demands are placing ever-greater strain on the advanced communications systems DAMAGE High Voltage through the communication lines can damage equipment and lead to major losses NECESSITY USAGE Deployment of electronics further into the network has resulted in miniaturization COST It is cheaper to install protective measures to mitigate high voltage surge than replacing damaged equipment
  • 6. 1 2 3 4 5 PROTECTION MEASURES Overvoltage protection devices consist of components or protective circuits that limit interference to permissible values Overvoltage protection devices must be adapted to regional and local requirements. Graded protective circuits with secondary protection elements should be used for incoming circuits on the exchange side and for terminal equipment (telephone, fax, modem) If active components are installed in a cross-connection cabinet, graded protective circuits are also recommended. Requirements include operating conditions on the line and protection requirements that result from the specific application area.
  • 7. OPERATING VOLTAGE The operating voltage of the system to be protected determines the protection plug’s voltage class. The protection device must not be triggered during normal operation as this would not only destroy the protective circuit, but would also lead to interruption in signal transmission. The highest possible voltage class should be selected for the protection plug – at least above the maximum voltage possible during operation (maximum operating voltage including tolerance). The upper limit for selecting the protection plug’s voltage class is determined by the maximum protection level permitted (the maximum input voltage that would not damage the downstream system components should overvoltage occur). The selection of components and switching configurations determines other electrical parameters for protective circuits. Properly designed and specified overvoltage protection components have a serviceable life of several decades and require no additional maintenance. CommScope recommends that the nominal DC spark-over voltage of installed protection components be tested regularly. For safety reasons, the arrestors should be replaced if the protective circuit has been subjected to impulse current.
  • 8. SELECTION Regardless of the series and circuit used, all overvoltage protection components rely on the same working principle: excessive voltages are discharged to earth. Depending on the component, the energy consumption of the protection device is relatively low. One precondition for this is the protection component’s low-resistance earthing. In line with signal potentials, a distinction is made between three-point and five-point protection. For connection modules, only three-point protection is possible. Five-point protection (components in the signal path) is recommended for use with switching modules. Once the protective plug is removed, the contact in the module is open and possible faults cannot make their way to the downstream network. Five-point protection can also be implemented using disconnection modules.
  • 9. OPERATING CONDITIONS Protection system design needs to meet the requirements of copper-based connection and distribution systems. In most applications, the protection modules are electrically equivalent; however, their contact and protection behaviour is not necessarily compatible Basic differentiators include: • Operating behaviour of the system to be protected • Overvoltage protection requirements (electrical and mechanical), for example requirements facing the permissible impulse current or the permissible AC discharge current. The network operator’s specifications must be observed when designing the protection modules. • Requirements for protection for a single pair, or an entire module
  • 10. COST BENEFIT When selecting overvoltage protection modules, the cost to-benefit ratio is key. The cost of installing protection modules is clearly offset by the increased availability of the communication network and lower repair costs. By carefully selecting equipment, network operators can minimize costs while realizing maximum economic efficiency of equipment. The extent of protection measures is based on requirements and specifications from the network operator or equipment manufacturer. To protect personnel, applicable standards and regulations for setting up and operating telecommunications networks must also be observed.