TOMAR Electronics design and manufacture highly reliable and efficient LED and strobe signal warning light systems, strobe beacons and audible alarms for hazardous area, explosion proof and non-hazardous area environment industries. TOMAR has been manufacturing their products for over 40 years and their warranties are among the longest in the industry, made possible due to the rigorous quality control standards and detailed inspections during the production process.
TOMAR products include: Hazardous Area & Explosion Proof LED / Strobe Warning / Signal Lighting LED Strobe Beacons Optical Preemption and Priority Control Systems Halogen Flood Lighting Alarm Sirens LED Lightbars Lightsticks & Traffic Directors LED, Strobe & Halogen Lightheads Digital Sirens & Control Panels Self-contained Systems Emergency Vehicle Systems Traffic Control Systems - STROBECOM II & STROBESWITCH II Fire Alarms Power Supplies
TOMAR industry solutions: Fire/EMS, Law Enforcement, Industrial, Amber Warning Products and Traffic
Thorne & Derrick are worldwide exporters of LV, HV & Hazardous Area Cable Installation & Electrical Equipment - we service UK and global businesses involved in cable installations, cable jointing, substation and electrical construction at LV, 11kV, 33kV and EHV. T&D service utilities, power, construction, rail, mining, offshore, oil, gas and petrochemical industries.
TOMAR hazardous area and explosion proof signal and warning light systems meet UL, CSA, NEMA and IECEx standards. Typical applications for the hazardous area, explosion proof LED and strobe lighting include manufacturing plants, chemical and petrochemical processing facilities, sewage treatment plants, offshore and dockside installations, agricultural, commercial, industrial, mining and marine facilities.
As described on www.iecex.com, the IECEx system is an international conformity system where a mark of conformity will be granted by approved IECEx certifiers (ExCBs) located in IECEx participating countries for equipment that is covered by an IECEx Certificate of Conformity and hence has been tested and manufactured under systems that are under ongoing surveillance by ExCBs. IECEx gives hazardous area industries an assurance that the electrical equipment being supplied for use in areas where flammable gases and vapours and combustible dusts (termed explosive atmospheres) are present, meet the world's most respected and vigorous safety standards.
2. TABLE OF CONTENTS
About Tomar........................................................................................
2-3
Visual Signals
MicroLert.............................................................................................
MicroLED.............................................................................................
500L Micro Lite ....................................................................................
LED Microstack....................................................................................
440 Microstack....................................................................................
Microstrobe.........................................................................................
Micro IV................................................................................................
500P Micro Lite....................................................................................
550P Micro Lite II.................................................................................
700 Mini Strobe...................................................................................
700 - 15J Mini Strobe.........................................................................
801 Mini Strobe...................................................................................
804 Maxi Strobe..................................................................................
8024 Mini Lite II...................................................................................
824 Multi-Strobe..................................................................................
3000ML/RML Power Strobe................................................................
3200/3300 ML/RML Power Strobe......................................................
3200 HP & HP/RML Power Strobe......................................................
7120R Power Strobe............................................................................
4-5
6-7
8-9
10 - 11
12 - 13
14 - 15
16 - 17
18 - 19
20 - 21
22 - 23
24 - 25
26 - 27
28 - 29
30 - 31
32 - 33
34 - 35
36 - 37
38 - 39
40 - 41
Hazardous Location & Explosion Proof Visual Signals
490S Hazardous Location Strobe........................................................
4375 Hazardous Location Strobe........................................................
2000XL Series......................................................................................
4000X Series.........................................................................................
3200BEP Explosion Proof Strobe........................................................
7120BEP Super Explosion Proof Strobe..............................................
3000 Series Explosion Proof LED Warning Lights...............................
7000 Series Super Explosion Proof LED Warning Lights....................
Parts & Accessories.............................................................................
42 - 43
44 - 45
46 - 47
48 - 49
50 - 51
52 - 53
54 - 55
56 - 57
58 - 59
Audible Alarms
1000 & 1100 Power Alarm..................................................................
1002WEP Explosion Proof Power Alarm Siren....................................
60 - 61
62 - 63
Fire Alarm Pull Stations
RMS.....................................................................................................
64 - 65
Break Glass Cover............................................................................... 65
RMS-WP Weather Proof......................................................................
66 - 67
RMS-EX-WP Explosion Proof & Weather Proof..................................
68 - 69
Vehicle Signals....................................................................................
70 - 71
Technical Reference............................................................................
72 - 79
Warranty.............................................................................................
inside back cover
3. VISUAL SIGNALS
For over 30 years, TOMAR Electronics, located in Gilbert, Arizona, has engineered, designed, and manufactured
the highest quality, most reliable and extremely efficient audible and visual warning signals. Tomar Electronics
is dedicated to perfecting strobe and LED technology and continues to define the standard for warning light
performance into the twenty-first century.
From assemblers to administration, TOMAR is continually improving manufacturing efficiencies while preserving
the consistent quality of our work. We take great pride in our efforts toward providing innovative products that
save lives.
Research and Development
The cornerstone of innovation.
The performance and reliability of TOMAR products evolves from over a quarter century of intensive research
and development of high efficiency electronic circuit designs and innovative optics.
TOMAR’s staff of highly specialized engineers employ state-of-the-art electronic design and testing equipment
to create the most advanced warning signals available. TOMAR’s testing and research equipment includes:
• An advanced computerized circuit simulator that defines critical tolerance parameters and troubleshoots
for potential design weaknesses.
• Surface Mount Technology Computer Automated (SMT) Component Pick and Place Assembly
• A 100 foot automated light measurement tunnel which uses photometers calibrated to display
measurements in candelas effective in accordance with FAA, and IES standards. High speed photodiodes
are used to measure and display light pulse wave shapes to insure accuracy in light intensity output
specifications.
• A fully equipped and certified test lab, capable of making all tests and measurements.
• A fast scanning spectroradiometer for color measurements.
2
TOMAR Electronics, Inc.
2100 W. Obispo Ave.
Gilbert, AZ 85233 USA
(800) 338-3133 tel
(800) 688-6627 fax
www.tomar.com
4. Manufacturing and Quality Control
Striving to produce high quality products.
Rigorous quality control standards and detailed inspections are implemented
at various stages in the production process. Fixture “burn-in” provides for
an unprecedented 100% testing of all TOMAR products to ensure accurate
and trouble free performance for the life of the strobe. Statistical Process
Control is used to monitor production quality with detailed precision.
TOMAR’s warranties are among the longest in the industry, made possible
by the dedication to quality in both the design and manufacturing processes.
A computerized system integrating order entry, inventory, and production
control helps to facilitate rapid order fulfillment.
Tomar Online
www.tomar.com
Visit our web site for the latest product up-dates, documentation and many
other helpful information. At www.tomar.com you can:
• Order additional copies of our catalogs
• Download any page of our catalogs in PDF format
• Download technical information and installation instructions for
Tomar products
• Request an RMA number
• Find up-to-date information on new and current products
• Find local distributors and much more
How we measure Light Intensity
The NBS (National Bureau of Standards) and the IES (Illumination Engineering Society) use candela Effective or Effective Candlepower (ECP) in specifying intensities of a flashing light source. This rating is the most meaningful when it
becomes necessary to predict the visible range of flashing warning lights versus steady burning light sources.
Peak Candela or Peak Candlepower is defined as “the maximum light intensity generated by a flashing light during
its light pulse. This is NOT a measurement of visible light, and therefore indicates nothing about how bright the light
appears to the human eye.
Visual Signaling Product photometric tests are performed using FAA and IES standard methods using visible light only.
The photometer used is an integrating photometer with photopic response detector. Photometer calibration is traceable to NBS standards.
3
5. STEADY-ON & FLASHING BEACONS
Mini LED Warning Light
Tomar introduces a totally new LED warning light.
The MicroLert offers unique features not before seen
in industrial signaling devices. It is the first such light
designed from the ground up to take full advantage of
LED lighting technology.
• 5-year warranty
• High power LED
• NEMA 4X
• UL Listed
The MicroLert features an integral inverted cone design
to provide full 360 degree coverage. The MicroLert lens
is engineered for maximum light output and color clarity,
and allows more of the LED light to be projected out than
do conventional Fresnel lenses.
• Wide AC and DC input voltage
• Lexan lens
• Steady-on or Flashing
• Surface, Pipe, or Thread mounts
• Sealed construction - NEMA 6P capable
• 5 LED colors-Amber, Blue, Green, Red,
and White
• Top Blackout Cap
44
TOMAR Electronics, Inc.
2100 W. Obispo Ave.
The tough Lexan lens is spun welded to the base to
completely seal out moisture. The MicroLert is UL listed
and manufactured to NEMA 4X specifications. It is
available in five LED colors (amber, blue, green, red, and
white); and in steady-burn or flashing models.
The MicroLert will operate over a wide AC and DC input
voltage ranges. The DC version is designed to operate
from 10-100 VDC and the AC version from 85-265 VAC.
The MicroLert is guaranteed against factory defects for a
full 5 years.
Gilbert, AZ 85233 USA
(800) 338-3133 tel
(800) 688-6627 fax
www.tomar.com
6. MICROLERT
440 STAND _________
For model 295L
thread mount only.
MAM-DS30 ___
270L - Flange Mount
290L - ½” Pipe Mount
295L - ½” Thread Mount
Accessories
Microlert Models
Item
Description
Voltage
Item
Description
440 STAND
Plastic Stand (For 295L thread mount MicroLert models only)
MAM-DS30
Wall mount bracket
270LF-12-80
Flashing Flange Mount
12-80 VDC
270LS-12-80
Steady-On Flange Mount
12-80 VDC
290LF-12-80
Flashing ½” Pipe Mount
12-80 VDC
290LF-120-240
Flashing ½” Pipe Mount
120-240 VAC
290LS-12-80
Steady-On ½” Pipe Mount
12-80 VDC
290LS-120-240
Steady-On ½” Pipe Mount
120-240 VAC
295LF-12-80
Flashing ½” Thread Mount
12-80 VDC
295LF-120-240
Flashing ½” Thread Mount
120-240 VAC
295LS-12-80
Steady-On ½” Thread Mount
12-80 VDC
295LS-120-240
Steady-On ½” Thread Mount
120-240 VAC
For blackout cap please add “-B” to the model number sequence.
Example for a red LED flashing, flange mount: 270LF-B-12-80-R
Specifications
Item
Description
Lamp Type
LED
Flash Rate
75 NEOBE® flashes per minute - each flash containing 7 rapid bursts of light (approximately 560
ms “on-time” and 240 ms “off-time”)
Voltage and
Amperage
200 mA @ 24VDC Flashing; 420 mA Steady-burn
040 mA @ 120 VAC Flashing; 085 mA Steady-burn
020 mA @ 240 VAC Flashing; 045 mA Steady-burn
Operating
Temperature
-40º to 85º C.
55
7. STEADY-ON & FLASHING BEACONS
LED Warning Signal
• 5-year warranty
Tomar Electronics’ 300-series flashing LED features a compact
version of the familiar Tomar Micro lens and base. Its innovative
inverted cone light focusing system assures maximum light
output and full 360 degree coverage.
• High power LED
• NEMA 4X
The MicroLED is the ideal choice for Lift Truck applications;
offering excellent flash intensity rivaling strobe lights, durable
vibration resistant construction, long life 100,000 hour LED
technology, backed up with a five year warranty.
• UL Recognized
• 12-80VDC input voltage
• 100,000 hour LED
The tough Lexan lens is spun welded to the base to
completely seal out moisture. The MicroLED is UL recognized
and manufactured to NEMA 4X specifications. It is available
in three LED colors (Amber, Blue, and Red). The choice of a
factory-installed clear lens is available for any color LED.
• Lexan Lens
• Neobe ® Flashing technology
• Pipe, thread or surface mounts
• Sealed Construction-NEMA 6P capable
The MicroLED will operate over a wide DC input voltage
range of 10 - 100 VDC. The MicroLED is guaranteed against
factory defects for a full 5 years.
Lens Colors
• 3 LED colors - Amber, Blue, Red
• Optional clear lens
6
TOMAR Electronics, Inc.
2100 W. Obispo Ave.
Amber
Gilbert, AZ 85233 USA
Blue
(800) 338-3133 tel
Red
Clear
(800) 688-6627 fax
www.tomar.com
8. MICROLED
Specifications
Ordering Information
Description
Model Description
Voltage
Item
Description
370L-1280-(Color)
Flashing Flange Mount
12-80 VDC
Lamp Type
LED
390L-1280-(Color)
Flashing Pipe Mount
12-80 VDC
Lamp Life
100,000 hours
395L-1280-(Color)
Flashing Thread Mount
12-80 VDC
Flash Rate
consisting of 7 rapid
bursts of light.
75 Neobe® flashes per minute – each
flash
Voltage and Amperage
200 mA @ 24 VDC
100 mA @ 48 VDC
50 mA @ 100 VDC
Operating temperature
-40º to 65º C
To specify a clear lens add “-C” to model description. example: 370L-1280-R-C
370L-1280
Flange Mount
390L-1280
1/2" Pipe Mount
395L-1280
1/2" Male Thread
G470
Heavy Duty Guard
Options
Model No.
Description
G470
Heavy duty guard
440 STAND
Plastic Stand (Thread mount
MicroLED models only)
MAM-DS30
Wall mount bracket
7
9. STEADY-ON & FLASHING BEACONS
500L MICRO LITE™
Tomar model 500L warning light features a super bright
white LED light engine and choice of six interchangeable
color lenses.
• 12 – 24VDC
All electronic components are encapsulated in
polyurethane for unparalleled protection against
moisture and vibration. It is available in 12-24 VDC, and
is warranted for a full 5 years.
• universal mounting
• 100,000 hour LED lamp
• five year warranty
The 500L offers a choice of 21 programmable flash modes
plus Steady burn, and the LED light source is rated at
100,000 hours of operation.
• NEMA 4X
Lens Colors
Amber
Blue
Clear
Green
Purple
Red
Ordering Information
Please specify lens colors and model number when ordering. Available colors are Amber, Blue, Clear, Green, Purple and Red.
Model No.
Voltage
500L–1224
8
Description
DC strobe, 1/2” female pipe mount
12 – 28VDC
TOMAR Electronics, Inc.
2100 W. Obispo Ave.
Gilbert, AZ 85233 USA
(800) 338-3133 tel
(800) 688-6627 fax
www.tomar.com
10. 500L
801-L
Lens
5.5" dia.
800-FLG
Flange Mounting Ring
Magnetic Base Mount
800-FLG
(optional)
Base
5.25"
G802
Heavy Duty Guard
BKT
Mounting Bracket
Specifications
Item
Description
Flash Rate
21 flash rates plus steady burn
Light Output
43 candela
Voltage and Amperage
0.3 A @ 24VDC flashing - 0.15A steady burn
Size and Weight
5.25” tall x 5.5” dia. x 2.0 lbs
Encapsulation
Fully potted in urethane material with no exposure to High Voltage possible
Operating Temperature
-40º to 65º C
( 133mm x 140mm x 0.9kg )
Available Options
NOTE: All “/“ options are factory installed only.
Model No.
Description
BKT
Mounting bracket
/LBO–MINILITE
Lens blackout segment 180º
802–03
Lens dust cover
G802
Guard
TBO–MAXI
Top lens blackout
800–FLG
Flange mounting ring
MINILITE SHIELD
Vinyl, 180º shield
9
11. STEADY-ON & FLASHING BEACONS
LED MICROSTACK™
Stackable Modules
The Tomar model PRE-F Microstack is a flashing or
steady burning modular light tower. It is ideally suited for
machine-status or process control signaling applications.
Consisting of a long life, high-output, and vibration
resistant LED lamp cluster, the PRE-F is designed to
increase productivity and greatly reduce maintenance
costs. The unique prism-cut lens design assures superior
light diffusion and greater lens fill. All components,
including the LED’s, are warranted for a full 5 years.
• 5-year warranty
The model PRE-F is available from one to five-high
configuration and in 24 VDC/AC, 120 VAC, and 240 VAC
versions.
• High power LED cluster
• Built-in Flasher
With the built-in Flasher, each light module can be
individually controlled for Flashing or Steady-on mode.
An optional 80 dB Sounder is available which can be
Factory installed or easily added later.
• 80 FPM
• CE Compliant
• 24 VDC/AC, 120 VAC, and 240 VAC
• 100,000 hour lamp life
• 56 mm (2.2”) diameter
Pre-wired and pre-assembled, each unit is ready for
installation right out of the box. If required, the lenses
can be separated without tools by simply twisting and
pulling them apart.
• IP 56
Lens Colors
• Factory assembled
• 80 db Optional Sounder
10
TOMAR Electronics, Inc.
2100 W. Obispo Ave.
Amber
Gilbert, AZ 85233 USA
Blue
(800) 338-3133 tel
Clear
Green
(800) 688-6627 fax
Red
www.tomar.com
12. led microstack
56mm
18mm
40mm
47mm
94mm
70mm
29mm
Specifications
Ordering Information
Model Description
Voltage
Amp Draw
Item
Description
PRE-F-1-024 LED Microstack, 1-High
24 VCD/AC
28 mA
Lamp Type
LED
PRE-F-1-120 LED Microstack, 1-High
120 VAC
25 mA
Lamp Life
100,000 hours
PRE-F-1-240 LED Microstack, 1-High
240 VAC
25 mA
Flash Rate
80 flashes per minute
Sounder
80 db @ 1m
Net weight
1 high - .9 lbs.
2 high - 1.1 lbs
3 high - 1.3 lbs
4 high - 1.5 lbs
5 high - 1.7 lbs
PRE-F-2-024 LED Microstack, 2-High
24 VCD/AC
62 mA
PRE-F-2-120 LED Microstack, 2-High
120 VAC
57 mA
PRE-F-2-240 LED Microstack, 2-High
240 VAC
57 mA
PRE-F-3-024 LED Microstack, 3-High
24 VCD/AC
102 mA
PRE-F-3-120 LED Microstack, 3-High
120 VAC
91 mA
PRE-F-3-240 LED Microstack, 3-High
240 VAC
91 mA
PRE-F-4-024 LED Microstack, 4-High
24 VCD/AC
136 mA
PRE-F-4-120 LED Microstack, 4-High
120 VAC
124 mA
PRE-F-4-240 LED Microstack, 4-High
240 VAC
124 mA
PRE-F-5-024 LED Microstack, 5-High
24 VCD/AC
169 mA
PRE-F-5-120 LED Microstack, 5-High
120 VAC
155 mA
PRE-F-5-240 LED Microstack, 5-High
240 VAC
155 mA
Accessories
Item
Description
MAP-0022
Pole, 22 mm
MAP-N033
Pole, 33 mm with 1/2” NPT threads
MAP-M043
Pole, 43 mm with M20 nuts
MAP-0240
Pole, 240 mm
MAP-M240
Pole, 240 mm with (2) M20 nuts
MAP-0750
Pole, 750 mm
MAP-M750
Pole, 750 mm with (2) M20 nuts
MAM-B070
Tulip base, 70 mm (2.75”) diameter
MAM-DS25
Wall mount “L” bracket for M20 pole and nut
MAM-DS30
Wall mount bracket
MPZ56E
Sounder, 24 VDC/AC to 240 VAC
11
13. VISUAL SIGNALS
440 MICROSTACK™
Strobe or NEOBE® Stackable Modules
The model 440 MICROSTACK™ features multi-color and
multi-format optical signaling using strobes and/or steady
burning and/or flashing NEOBE® lamps in any combination.
NEOBE® lamps are gas discharge lamps which have no
filament to wear out or break. All MICROSTACK modules
operate over a worldwide AC input voltage range of 85–
264VAC 50/60 Hz. They all use the same type of lamp
and maintain a constant brightness and flash rate over the
entire range. MICROSTACK modules separate at any level
by removing two screws. All MICROSTACK modules are
sealed with o-rings so they may be used outdoors and in
dusty indoor conditions. Lamp colors available in Amber,
Blue, Clear, Green and Red.
• components or preassembled units
• steady burn or flashing
• outdoor or indoor use
• xenon strobe lamp
• two year warranty on power supply
• one year warranty on lamp
• available in five lens colors
Specifications
Item
Voltage and Amperage
85–264VAC 50/60 Hz, 0.06 A average
7 watts per module
Flash Rate
60 to 80 FPM
Size
3.32” dia. (84mm)
Height (including base and stand)
12
Description
7.7”
10.0”
12.3”
14.6”
16.9”
TOMAR Electronics, Inc.
2100 W. Obispo Ave.
(196mm)
(254mm)
(312mm)
(371mm)
(429mm)
( model 440–1 )
( model 440–2 )
( model 440–3 )
( model 440–4 )
( model 440–5 )
Gilbert, AZ 85233 USA
(800) 338-3133 tel
(800) 688-6627 fax
www.tomar.com
14. 440 microstack
82mm
440-CAP
22mm
Module
70mm
5002 Xenon
Strobe Lamp
51mm
440-BASE
__________ MAM-DS30
440-STAND
70mm
Ordering Information
The MICROSTACK can be ordered as a preassembled unit or as components or modules.
Preassembled MICROSTACKS
Model No.
Description
440–1
One module MICROSTACK
440–2
Two module MICROSTACK
440–3
Three module MICROSTACK
440–4
Available Colors
Four module MICROSTACK
440–5
Module Options
Five module MICROSTACK
Replacement Parts
Module type
Color
Steady Burn NEOBE®
Amber
Strobe
Blue
Flashing NEOBE®
Clear
Green
Red
Accessories
Model No.
Description
Item
Description
440–BASE
Base and cover, less stand
440 STAND
440–STAND
Stand for base including gasket
Plastic Stand (Thread mount MicroLert
models only)
440–CAP
Cap for MICROSTACK™ module
MAM-DS30
Wall mount bracket
440S
Strobe module including lamp ( please specify color
— Amber, Blue, Clear, Green or Red )
440SB
Steady burn NEOBE® including lamp ( please specify
color — Amber, Blue, Clear, Green or Red )
440FN
Flashing NEOBE® including lamp ( please specify color
— Amber, Blue, Clear, Green or Red )
5002
Spare lamp for MICROSTACK™ module
440–T16
16” extension tube
440–T32
32” extension tube
440–DEMOBASE
Demonstrator with switch base
13
15. VISUAL SIGNALS
MICROSTROBE®
Low Profile - Single Flash Strobe
• built-in RFI filters
• lens has hermetic o-ring seal
• solid state power supply
• 10,000 hour strobe lamp
• two year warranty on power supply
• one year warranty on lamp
The MICROSTROBE® family is a low profile, single flash,
low cost strobe light which features a plug-in replaceable
lamp and Lexan® lens. The high efficiency, solid state,
power supply is fully potted in polyurethane for
the ultimate in protection from moisture, vibration and
exposure tohigh voltage. All units are polarity protected
and have built-in filters to protect against radio
interference and spike voltages.
• available in six lens colors
Lens Colors
• UL listed
• NEMA 4X
Amber
Blue
Clear
Green
Purple
Red
Ordering Information
Please specify lens colors and model number when ordering. Available colors are Amber, Blue, Clear, Green, Purple, and Red.
Model No.
Description
Voltage/Frequency
470SSGP–120
AC strobe, wall plate mount
120VAC, 50/60Hz
480S–120
AC strobe, surface mount, AC cord set
120VAC, 50/60Hz
480SMB–120
AC strobe, magnetic mount
120VAC, 50/60Hz
485S-120
AC strobe, screw-in light bulb base
120VAC, 50/60Hz
485S-240
AC strobe, screw-in light bulb base
240VAC, 50/60Hz
490S–120
AC strobe, 1/2” female pipe mount
120VAC, 50/60Hz
490S–240
AC strobe, 1/2” female pipe mount
240VAC, 50/60Hz
492S–120
AC strobe, 3/4” IPS slip mount
120VAC, 50/60Hz
495S–120
14
AC strobe, 1/2” male thread mount
120VAC, 50/60Hz
495S–240
AC strobe, 1/2” male thread mount
240VAC, 50/60Hz
TOMAR Electronics, Inc.
2100 W. Obispo Ave.
Gilbert, AZ 85233 USA
(800) 338-3133 tel
(800) 688-6627 fax
www.tomar.com
16. microstrobe
470SSGP-120
Wall Plate Mount
480S-120
Surface Mount
480SMB-120
Magnetic Mount
440 STAND ________
490S-120
1/2" Pipe Mount
492S-120
3/4" IPS Slip Mount
3" dia.
BKT
Mounting Bracket
470S-L
Lens
5001 Xenon
Strobe Lamp
5"
MAM-DS30 ____
480S-120-BASE
Power Supply
485S
Screw-in Light
Bulb Base
495S-120
1/2" Male Thread
G470
Heavy Duty Guard
Specifications
Item
Description
Flash Rate
60 to 80 flashes per minute
Light Output
50 effective candlepower (ECP)*
Voltage and Amperage
120VAC and 240VAC draw 0.07A average
Power Supply Output 2.7 Watts
1.9 joules per flash. 190,000 Peak Candlepower**
Size and Weight
5” tall x 3” dia. x 0.5 lbs
Operating Temperature
-40 C to 65 C
Encapsulation
Fully potted in urethane material with no exposure to High Voltage possible
( 127mm x 76mm x 0.23kg )
Available Options
NOTE: All “/“ options are factory installed only.
Mounting Options
Model No.
Description
Item
Description
G470
Heavy duty guard
BKT
Mounting bracket
LBO–MINI
Lens blackout segment 180º
440 STAND
MICROSHIELD
Vinyl, 180º lens blackout
Plastic Stand (Thread mount MicroLert
models only)
/TRIAC–SW
Solid state relay option
MAM-DS30
Wall mount bracket
Replacement Parts
Architect and Engineer Specifications
The strobe light shall be Tomar model number series 470,
480, 485, 490,492, 495 or approved equal. The light source
shall be a plug-in field replaceable single-flash xenon
strobe tube. The strobe light must have built-in RFI filters
to protect against radio interference and spike voltages. It
shall be polarity protected, and have a power supply fully
potted in polyurethane. Voltage ranges shall be 12-80VDC
or 16-24VAC, 120 VAC, and 240VAC. The strobe light shall
be UL listed and of NEMA 4X type weatherproof design
with screw-on Lexan® lens.
Model No.
Description
5001
Xenon strobe lamp
470S–L
Colored lens ( please specify color )
480S–120–PSA
120VAC power supply, surface mount
480SMB–120–PSA
120VAC power supply, magnetic mount
485S–120–PSA
120VAC power supply, screw-in light bulb base
485S–240–PSA
240VAC power supply, screw-in light bulb base
490S–120–PSA
120VAC power supply, 1/2” female pipe mount
490S–240–PSA
240VAC power supply, 1/2” female pipe mount
492S–120–PSA
120VAC power supply, 3/4” IPS slip mount
*ECP (Effective Candlepower) is the intensity that would appear to
an observer if the light were burning steadily.
495S–120–PSA
120VAC power supply, 1/2” male thread mount
495S–240–PSA
240VAC power supply, 1/2” male thread mount
**Peak Candlepower is the maximum light intensity generated by a
flashing light during its light pulse.
15
17. VISUAL SIGNALS
MICRO IV™
Low Profile - Single Flash Strobe
• wide input voltage range
• universal mounting
• built-in RFI filters
• 10,000 hour strobe lamp
• ten year warranty on power supply
• one year warranty on lamp
• available in six lens colors
• UL recognized (all models)
The MICRO IV strobe family is an enhanced version of
the MICROSTROBE featuring a power supply which
operates over a wide input voltage range of 12–80VDC
or 16–24VAC. The supply has a regulated output so that
the lamp brightness and flash remain constant when
operated over the rated input voltage range. The power
supply is potted in polyurethane for the ultimate in
protection from moisture, vibration and exposure to high
voltage. The enclosure is all Lexan®, and the plug-in lamp
is field replaceable. All units are polarity protected and
have built-in filters to protect against radio interference
and spike voltages. The MICRO IV is covered by a 10 year
warranty. The MICRO IV and its guard are UL component
recognized for type E, EE, and ES electric industrial trucks
covered by UL standard #583.
Lens Colors
• lens has hermetic o-ring seal
• NEMA 4X
Amber
Blue
Clear
Green
Purple
Red
Ordering Information
Please specify lens colors and model number when ordering. Available colors are Amber, Blue, Clear, Green, Purple and Red.
Model No.
Voltage
470SSGP–1280
DC strobe, wall plate mount
12 – 80VDC
470S–1280
DC strobe, surface mount
12 – 80VDC
470SMB–1280
DC strobe, magnetic mount and 6’ straight cord
12 – 80VDC
470SMB–1280/CC
DC strobe, magnetic mount and coil cord
12 – 80VDC
490S–1280
DC strobe, 1/2” female pipe mount
12 – 80VDC
492S–1280
DC strobe, 3/4” IPS slip mount
12 – 80VDC
495S–1280
16
Description
DC strobe, 1/2” male thread mount
12 – 80VDC
TOMAR Electronics, Inc.
2100 W. Obispo Ave.
Gilbert, AZ 85233 USA
(800) 338-3133 tel
(800) 688-6627 fax
www.tomar.com
18. micro iv
3" dia.
470SSGP-1280
Wall Plate Mount
490S-1280
1/2" Pipe Mount
470S-1280
Surface Mount
470SMB-1280
Magnetic Mount
492S-1280
3/4" IPS Slip Mount
BKT
Mounting Bracket
470S-L
Lens
5001 Xenon
Strobe Lamp
440 STAND ________
5"
MAM-DS30 ____
470S-1280-BASE
Power Supply
485S-1280
Screw-in
Light Bulb Base
495S-1280
1/2" Male Pipe
Thread Mount
G470
Heavy Duty Guard
Specifications
Item
Description
Flash Rate
60 to 80 flashes per minute
Light Output
50 effective candlepower (ECP)*
Voltage and Amperage
12-80VDC draws 0.4A average @ 12VDC tapering to 0.05A average @ 80VDC
16-24VAC draws 0.35A average
Power Supply Output 2.7 Watts
1.9 joules per flash. 190,000 Peak Candlepower**
Size and Weight
5” tall x 3” dia. x 0.6 lbs
Operating Temperature
-40 C to 65 C
Encapsulation
Fully potted in urethane material with no exposure to High Voltage possible
( 127mm x 76mm x 0.27kg )
Available Options
NOTE: All “/“ options are factory installed only.
Mounting Options
Model No.
Description
Item
Description
G470
Heavy duty guard
BKT
Mounting bracket
BKT
Mounting bracket
440 STAND
LBO–MINI
Lens blackout segment 180º
Plastic Stand (Thread mount MicroLert
models only)
MICROSHIELD
Vinyl, 180º lens blackout
MAM-DS30
Wall mount bracket
Replacement Parts
Model No.
Description
5001
Xenon strobe lamp
470S–L
Colored lens ( please specify color )
470S–1280–PSA
12 – 80VDC power supply, surface mount
470SMB–1280–PSA
12 – 80VDC power supply, magnetic mount and 6’ straight cord
470SMB–1280/CCB
12 – 80VDC power supply, magnetic mount and coil cord
490S–1280–PSA
12 – 80VDC power supply, 1/2” female pipe mount
492S–1280–PSA
12 – 80VDC power supply, 3/4” IPS slip mount
495S–1280–PSA
12 – 80VDC power supply, 1/2” male thread mount
Architect and Engineer Specifications
The strobe light shall be Tomar model number series 470,
480, 485, 490, 492, 495 or approved equal. The light source
shall be a plug-in field replaceable single-flash xenon
strobe tube. The strobe light must have built-in RFI filters
to protect against radio interference and spike voltages. It
shall be polarity protected, and have a power supply fully
potted in polyurethane. Voltage ranges shall be 12-80VDC
or 16-24VAC, 120 VAC, and 240VAC. The strobe light shall
be UL listed and of NEMA 4X type weatherproof design
with screw-on Lexan® lens.
*ECP (Effective Candlepower) is the intensity that would appear to
an observer if the light were burning steadily.
**Peak Candlepower is the maximum light intensity generated by a
flashing light during its light pulse.
17
19. VISUAL SIGNALS
500P MICRO LITE™
Low Profile - Single Flash Strobe
• 12 – 28VDC
• universal mounting
• built-in RFI filters
• solid state power supply
• 10,000 hour strobe lamp
• two year warranty on power supply
The model 500P family is a low profile single flash strobe
light featuring a wide input voltage range of 12–28VDC,
universal mounting, Lexan® lens, high efficiency regulated
solid state potted power supply, and heavy duty xenon
strobe lamp. All units are polarity protected and have
built-in filters to protect against radio interference and
spike voltages. The model 500P features a fully potted,
Lexan®, multi-purpose mounting base which is vibration
and water resistant, and a field replaceable plug-in strobe
lamp.
• one year warranty on lamp
Lens Colors
• Meets FAA AC 150/5210-5D
• NEMA 4X
Amber
Blue
Clear
Green
Purple
Red
Ordering Information
Please specify lens colors and model number when ordering. Available colors are Amber, Blue, Clear, Green, Purple and Red.
Model No.
Description
Voltage
500P–1228
DC strobe, 1/2” female pipe mount
12 – 28VDC
500PMB–1228
18
DC strobe, magnetic base with 10’ coil cord
12 – 28VDC
500PMBSC–1228
DC strobe, magnetic base with 10’ straight cord
12 – 28VDC
TOMAR Electronics, Inc.
2100 W. Obispo Ave.
Gilbert, AZ 85233 USA
(800) 338-3133 tel
(800) 688-6627 fax
www.tomar.com
20. 500p micro lite
801-L
Lens
5.5" dia.
800-FLG
Flange Mounting Ring
Magnetic Base Mount
2001 Xenon
Strobe Lamp
800-FLG
(optional)
5.25"
Base
G802
Heavy Duty Guard
BKT
Mounting Bracket
Specifications
Item
Description
Flash Rate
70 to 90 flashes per minute
Light Output
200 effective candlepower (ECP)* from 0º horizontal up to 10º above the horizontal
Voltage and Amperage
12-28VDC draws 0.8A average @ 12VDC tapering to 0.4A average @ 24VDC
Power Supply Output 8 Watts
6 joules per flash. 600,000 Peak Candlepower**
Size and Weight
5.25” tall x 5.5” dia. x 2.0 lbs
Encapsulation
Fully potted in urethane material with no exposure to High Voltage possible
( 133mm x 140mm x 0.9kg )
Available Options
NOTE: All “/“ options are factory installed only.
Model No.
Description
BKT
Mounting bracket
/LBO–MINILITE
Lens blackout segment 180º
802–03
Lens dust cover
G802
Guard
TBO–MAXI
Top lens blackout
800–FLG
Flange mounting ring
MINILITE SHIELD
Vinyl, 180º shield
Replacement Parts
Model No.
Description
2001
Xenon strobe lamp
801–L
Color lens ( please specify color )
500P–1228–BASE
12–28VDC power supply with magnetic base and coil cord
500PMBSC–BASE
*ECP (Effective Candlepower) is the intensity that would appear to
an observer if the light were burning steadily.
12–28VDC power supply
500PMB–BASE
Architect and Engineer Specifications
The visual warning signaling device shall be Tomar model
500P or approved equal. The light source shall be a plugin field replaceable single-flash xenon strobe tube. The
strobe light shall have a Lexan® lens and universal mount
base. The warning signal must have built-in RFI filters to
protect against radio interference and spike voltages. It
shall be polarity protected, and have a power supply fully
potted in polyurethane. The power supply output shall be
8 watts and generate 6 joules per flash. Voltage shall be
multiple input of 12-28VDC. Strobe light shall be designed
to accept a dome guard, 180 degree lens blackout, and
straight or coiled cigar plug.
12–28VDC power supply with magnetic base and straight cord
**Peak Candlepower is the maximum light intensity generated by a
flashing light during its light pulse.
19
21. VISUAL SIGNALS
550P MICRO LITE II™
Low Profile - High Output Single Flash Strobe
The model 550P family is a low profile single flash strobe
light featuring a multiple input voltage rating of 12–
74VDC, universal mounting, Lexan® lens, high efficiency
regulated solid state potted power supply, and heavy duty
xenon strobe lamp. All units are polarity protected and
have built-in filters to protect against radio interference
and spike voltages. The model 550P features a field
replaceable plug-in strobe lamp and is UL component
recognized for use on type E, EE, and ES electric industrial
trucks covered by UL standard #583.
• 12 – 74 VDC
• universal mounting
• built-in RFI filters
• solid state power supply
• 10,000 hour strobe lamp
• two year warranty on power supply
• one year warranty on lamp
• available in six lens colors
Lens Colors
• UL recognized (all models)
• NEMA 4X
Amber
Blue
Clear
Green
Purple
Red
Ordering Information
Please specify lens colors and model number when ordering. Available colors are Amber, Blue, Clear, Green, Purple and Red.
Model No.
Voltage
DC strobe, 1/2” female pipe mount
12 – 74VDC
550PMB–1274
DC strobe, magnetic base with 10’ coil cord
12 – 74VDC
550PMBSC–1274
20
Description
550P–1274
DC strobe, magnetic base with 10’ straight cord
12 – 74VDC
TOMAR Electronics, Inc.
2100 W. Obispo Ave.
Gilbert, AZ 85233 USA
(800) 338-3133 tel
(800) 688-6627 fax
www.tomar.com
22. 550p micro lite ii
801-L
Lens
5.5" dia.
800-FLG
Flange Mounting Ring
Magnetic Base Mount
2001 Xenon
Strobe Lamp
800-FLG
(optional)
5.25"
Base
G802
Heavy Duty Guard
BKT
Mounting Bracket
Specifications
Item
Description
Flash Rate
70 to 90 flashes per minute
Light Output
270 effective candlepower (ECP)*
Voltage and Amperage
12-74VDC draws 1.25A average @ 12VDC tapering to 0.2A average @ 74VDC
Power Supply Output 11 Watts
12 joules per flash. 1,200,000 Peak Candlepower**
Size and Weight
5.25” tall x 5.5” dia. x 2.0 lbs
Encapsulation
Fully potted in urethane material with no exposure to High Voltage possible
( 133mm x 140mm x 0.9kg )
Available Options
NOTE: All “/“ options are factory installed only.
Model No.
Description
BKT
Mounting bracket
/LBO–MINILITE
Lens blackout segment 180º
802–03
Lens dust cover
G802
Guard
TBO–MAXI
Top lens blackout
800–FLG
Flange mounting ring
MINILITE SHIELD
Vinyl, 180º shield
Replacement Parts
Model No.
Description
2001
Xenon strobe lamp
801–L
Color lens ( please specify color )
550P–BASE
12–74VDC power supply
550PMB–BASE
12–74VDC power supply with magnetic base and coiled cord
550PMBSC–BASE
Architect and Engineer Specifications
The visual signaling beacon shall be Tomar model 550P or
approved equal. The light source shall be a plug-in field
replaceable single-flash xenon strobe lamp. The warning
beacon shall have a Lexan® lens and universal mount base.
The warning signal must have built-in RFI filters to protect
against radio interference and spike voltages. It shall be
polarity protected, and have a power supply fully potted
in polyurethane. The power supply output shall be11
watts and generate 12 joules per flash. Voltage shall be
multiple input of 12-74VDC. Strobe light shall be designed
to accept a dome guard, 180 degree lens blackout, and
straight or coiled cigar plug. The warning beacon shall be
UL component recognized for use on type E, EE, and ES
electrical industrial trucks covered by UL standard # 583.
12–74VDC power supply with magnetic base and straight cord
*ECP (Effective Candlepower) is the intensity that would appear to
an observer if the light were burning steadily.
**Peak Candlepower is the maximum light intensity generated by a
flashing light during its light pulse.
21
23. VISUAL SIGNALS
700 MINI STROBE®
Single Flash Warning Light
• aluminum housing
• heavy duty construction
• solid state power supply
• 10,000 hour strobe lamp
• two year warranty on power supply
The model 700 MINI STROBE family is a single flash heavy
duty strobe light featuring an all aluminum housing, flange
mounting, 360° Lexan® lens, high efficiency regulated
solid state power supply and a plug-in field replaceable
heavy duty xenon strobe lamp. The 700–1274 will
operate over 12–74VDC without making any changes or
adjustments. DC models are UL component recognized
for use on type E, EE, and ES electric industrial trucks
covered by UL standard #583.
• one year warranty on lamp
• available in six lens colors
• UL recognized (DC models only)
Lens Colors
• NEMA 3R
• available in 120 VDC
Amber
Blue
Clear
Green
Purple
Red
Ordering Information
Please specify lens colors and model number when ordering. Available colors are Amber, Blue, Clear, Green, Purple and Red.
Model No.
Description
Voltage/Frequency
700–110
AC strobe
120VAC, 50/60HZ
700–240
AC strobe
240VAC, 50/60HZ
700–1274
DC strobe, UL recognized
12 – 74VDC
700–120DC
DC strobe, UL recognized
120VDC
Mounting Options
NOTE: All “/“ options are factory installed only.
Model No.
/PM1
1/2” pipe mount
/M
22
Description
Magnetic mount #90 magnet
TOMAR Electronics, Inc.
2100 W. Obispo Ave.
Gilbert, AZ 85233 USA
(800) 338-3133 tel
(800) 688-6627 fax
www.tomar.com
24. 700 mini
4.7" dia.
/GM (Guard) and
BKT (Mounting Bracket) options
shown with strobe
6"
/M
Magnetic Mounting option
/PM1
1/2" Pipe Mount option
Specifications
Item
Description
Flash Rate
80 to 95 flashes per minute
Light Output
185 effective candlepower (ECP)*
Voltage and Amperage
12-74VDC draws 1.25 A average @ 12VDC tapering to draws 0.2A average @ 74VDC
120VAC draws 0.17A average
120VDC draws 0.1A average
240VAC draws 0.12A average
Power Supply Output 11 Watts
8 joules per flash. 800,000 Peak Candlepower**
Size and Weight
6” tall x 4.7” dia. x 1.3 lbs ( 152mm x 119mm x 0.58kg )
Available Options
NOTE: All “/“ options are factory installed only.
Model No.
Description
/GM
Guard
/CP
10’ straight cord and cigar plug
/LBO–MINI
Lens blackout segment 180º
/CC
10’ coil cord with cigar plug
BKT
Bracket
/DEMO
Demo prep with battery clamps
MICROSHIELD
Vinyl, 180º lens blackout
700–DC
Clear lens dust cover
Replacement Parts
Model No.
Description
3001
110–120 VAC power supply
700–PCB–120DC
120VDC power supply
700–PCB–1274
12–74 VDC power supply
700–110–15J–PCB
**Peak Candlepower is the maximum light intensity generated by a
flashing light during its light pulse.
Color lens ( please specify color )
700–PCB–110
*ECP (Effective Candlepower) is the intensity that would appear to
an observer if the light were burning steadily.
Xenon strobe lamp ( 700 family )
700-L
Architect and Engineer Specifications
The visual signaling beacon shall be Tomar model 700 or
approved equal. The light source shall be a plug-in field
replaceable single flash xenon strobe lamp and having a
flash rate of 80 to 90 flashes per minute. Housing material
shall be aluminum with a 360 degree Lexan® lens, and
either flange, magnetic, or pipe mount. Voltage ranges
shall be 12-74VDC, 120VAC, 120VDC, and 240VAC. Power
supply output shall be 11 watts and generating either 8 or
15 joules per flash depending on the model. Strobe light
shall be designed to accept a dome guard, 180 degree
lens blackout, and straight or coiled cigar plug.
110–120 VAC 15 joule power supply
23
25. VISUAL SIGNALS
700-15J MINI STROBE®
High Output Single Flash
Warning Light
The model 700-15J High Output Mini Strobe is similar to
the Model 700 Mini Strobe, but features a high power
15 joule power supply which generates 360 Effective
Candlepower.
• aluminum housing
• heavy duty construction
• solid state power supply
• 10,000 hour strobe lamp
• two year warranty on power supply
• one year warranty on lamp
• available in six lens colors
Lens Colors
• NEMA 3R
• 360 ECP
Amber
Blue
Clear
Green
Purple
Red
Ordering Information
Please specify lens colors and model number when ordering. Available colors are Amber, Blue, Clear, Green, Purple and Red.
Model No.
Description
Voltage/Frequency
700–110-15J
AC strobe, 15 joule
120VAC, 50/60HZ
Mounting Options
NOTE: All “/“ options are factory installed only.
Model No.
/PM1
1/2” pipe mount
/M
24
Description
Magnetic mount #90 magnet
TOMAR Electronics, Inc.
2100 W. Obispo Ave.
Gilbert, AZ 85233 USA
(800) 338-3133 tel
(800) 688-6627 fax
www.tomar.com
26. 700-15j Mini
4.7" dia.
/GM (Guard) and
BKT (Mounting Bracket) options
shown with strobe
6"
/M
Magnetic Mounting option
/PM1
1/2" Pipe Mount option
Specifications
Item
Description
Flash Rate
80 to 95 flashes per minute
Light Output
360 effective candlepower (ECP)*
Voltage and Amperage
0.17 @ 120VAC
Power Supply Output 11 Watts
15 joules per flash. 1,500,000 Peak Candlepower**
Size and Weight
6” tall x 4.7” dia. x 1.3 lbs ( 152mm x 119mm x 0.58kg )
Available Options
NOTE: All “/“ options are factory installed only.
Model No.
Description
/GM
Guard
/LBO–MINI
Lens blackout segment 180º
BKT
Bracket
Replacement Parts
Model No.
Description
6001
Xenon strobe lamp ( 700–110–15J )
700-L
Color lens ( please specify color )
700–110–15J–PCB
110–120 VAC 15 joule power supply
Architect and Engineer Specifications
The visual signaling beacon shall be Tomar model 700 or
approved equal. The light source shall be a plug-in field
replaceable single flash xenon strobe lamp and having a
flash rate of 80 to 90 flashes per minute. Housing material
shall be aluminum with a 360 degree Lexan® lens, and
either flange, magnetic, or pipe mount. Voltage ranges
shall be 12-74VDC, 120VAC, 120VDC, and 240VAC. Power
supply output shall be 11 watts and generating either 8 or
15 joules per flash depending on the model. Strobe light
shall be designed to accept a dome guard, 180 degree
lens blackout, and straight or coiled cigar plug.
*ECP (Effective Candlepower) is the intensity that would appear to
an observer if the light were burning steadily.
**Peak Candlepower is the maximum light intensity generated by a
flashing light during its light pulse.
25
27. VISUAL SIGNALS
801 MINI I™ STROBE
Low Profile - Single Flash
Warning Light
• universal mounting
• built-in RFI filters
• solid state power supply
• 10,000 hour strobe lamp
• five year warranty on power supply
• one year warranty on lamp
• available in six lens colors
The model 801 family is a low profile, single flash strobe
light featuring universal mounting, low profile 360° Lexan®
lens, high efficiency regulated solid state power supply,
and heavy duty xenon strobe lamp. All units are polarity
protected and have built-in filters to protect against radio
interference and spike voltages. The model 801 features a
fully potted, Lexan®, multi-purpose mounting base which
is vibration and water resistant. The 801 also features a
field replaceable plug-in strobe lamp and a state of the
art energy storage capacitor for increased intensity.
• UL listed (where noted below)
Lens Colors
• NEMA 4X
• 400 ECP
Amber
Blue
Clear
Green
Purple
Red
Ordering Information
Please specify lens colors and model number when ordering. Available colors are Amber, Blue, Clear, Green, Purple and Red.
Model No.
Voltage/Frequency
AC strobe with 10” leads, UL listed
120VAC, 50/60Hz
801LC–110
AC strobe with AC cord set, UL listed
120VAC, 50/60Hz
801LCMB–110
AC strobe, magnetic mount and cord
120VAC, 50/60Hz
801–240
AC strobe with 10” leads, UL listed
240VAC, 50/60Hz
801–1274
DC strobe with 10” leads, 800–FLG
12 – 74VDC
801MB–1274
DC strobe, magnetic mount and 10’ coil cord
12 – 74VDC
801MBSC–1274
26
Description
801–110
DC strobe, magnetic mount and 10’ straight cord
12 – 74VDC
TOMAR Electronics, Inc.
2100 W. Obispo Ave.
Gilbert, AZ 85233 USA
(800) 338-3133 tel
(800) 688-6627 fax
www.tomar.com
28. 801 Mini i
5.5" dia.
800-FLG
Flange Mounting Ring
801-L
Lens
Magnetic Base Mount
4001 Xenon
Strobe Lamp
800-FLG
(optional on
AC versions)
5.25"
Base
G802
Heavy Duty Guard
BKT
Mounting Bracket
Specifications
Item
Description
Flash Rate
80 to 95 flashes per minute
Light Output
400 effective candlepower (ECP)*
Voltage and Amperage
12-74VDC draws 1.25A @ 12V tapering to 0.2A average @ 74V
120VAC draws 0.3A average
240VAC draws 0.3A average
Power Supply Output 11 Watts
8 joules per flash. 800,000 Peak Candlepower**
Operating Temperature
-40 C to 65 C
Size and Weight
5.25” tall x 5.5” dia. x 2.0 lbs
Encapsulation
Fully potted in urethane material with no exposure to High Voltage possible
( 133mm x 140mm x 0.9kg )
Available Options
NOTE: All “/“ options are factory installed only.
Model No.
Description
BKT
Mounting bracket
/LBO–MINILITE
Lens blackout segment 180º
802–03
Lens dust cover
G802
Heavy duty guard
TBO–MAXI
Top lens blackout
800–FLG
Chrome flange mounting ring ( standard on DC versions,
optional on AC versions )
MINILITE SHIELD
Vinyl, 180º shield
Replacement Parts
Model No.
Description
4001
Xenon strobe lamp
801–L
Color lens ( please specify color )
801–110–BASE
120VAC power supply
801LC–BASE
120VAC power supply with AC cord set
801LCMB–BASE
120VAC power supply with magnetic mount and AC cord
801–240–BASE
240VAC power supply
801–1274–BASE
12–74VDC power supply
801MB–BASE
Architect and Engineer Specifications
The visual signaling beacon shall be Tomar model 801 or
approved equal. The light source shall be a plug-in field
replaceable single-flash xenon strobe lamp. The warning
beacon shall have a Lexan® lens and universal mount
base. The warning signal must have built-in RFI filters to
protect against radio interference and spike voltages. It
shall be polarity protected, and have a power supply fully
potted in polyurethane. The beacon shall have an 11 watt
power supply, and generate 8 joules per flash at 80 to 95
flashes per minute. Light intensity is to be 400 effective
candlepower, and voltage ranges shall be 12-74VDC, 120
VAC, and 240VAC. Strobe light shall be designed to accept
a dome guard and mounting bracket.
12–74VDC power supply with magnetic mount and coil cord
*ECP (Effective Candlepower) is the intensity that would appear to
an observer if the light were burning steadily.
**Peak Candlepower is the maximum light intensity generated by a
flashing light during its light pulse.
27
29. VISUAL SIGNALS
804 MAXI I™ STROBE
Medium Profile - Single Flash
Warning Light
• universal mounting
• built-in RFI filters
• solid state power supply
• 10,000 hour strobe lamp
• five year warranty on power supply
• one year warranty on lamp
• available in six lens colors
The model 804 family is a medium profile, single flash
strobe light featuring universal mounting, full size 360°
Lexan® lens, high efficiency regulated solid state power
supply, and heavy duty xenon strobe lamp. All units are
polarity protected and have built-in filters to protect
against radio interference and spike voltages. The
model 804 features a fully potted Lexan®, multi-purpose
mounting base which is vibration and water resistant. The
804 also features a field replaceable plug-in strobe lamp
and state of the art energy storage capacitor for increased
intensity.
• UL listed (AC models only)
Lens Colors
• NEMA 4X
• 480 ECP
Amber
Blue
Clear
Green
Purple
Red
Ordering Information
Please specify lens colors and model number when ordering. Available colors are Amber, Blue, Clear, Green, Purple and Red.
Model No.
Voltage, Frequency
804–110
AC strobe with 10” leads, UL listed
120VAC, 50/60Hz
804LC–110
AC strobe with AC cord set, UL listed
120VAC, 50/60Hz
804–240
AC strobe with 10” leads, UL listed
240VAC, 50/60Hz
804–1274
DC strobe with 10” leads
12 – 74VDC
804MB–1274
DC strobe, magnetic mount and 10’ coil cord
12 – 74VDC
804MBSC–1274
28
Description
DC strobe, magnetic mount and 10’ straight cord
12 – 74VDC
TOMAR Electronics, Inc.
2100 W. Obispo Ave.
Gilbert, AZ 85233 USA
(800) 338-3133 tel
(800) 688-6627 fax
www.tomar.com
30. 804 Maxi I
5.5" dia.
800-FLG
Flange Mounting Ring
1700 Lens
Magnetic Base Mount
4001 Xenon
Strobe Lamp
6.75"
800-FLG
(optional on
AC versions)
Base
G800
Heavy Duty Guard
BKT
Mounting Bracket
Specifications
Item
Description
Flash Rate
80 to 95 flashes per minute
Light Output
480 effective candlepower (ECP)*
Voltage and Amperage
12-74VDC draws 1.25A @ 12V tapering to 0.2A average @ 74V
120VAC draws 0.3A average
240VAC draws 0.3A average
Power Supply Output 11 Watts
8 joules per flash. 800,000 Peak Candlepower**
Operating Temperature
-40 C to 65 C
Size and Weight
6.75” tall x 5.5” dia. x 2.2 lbs
Encapsulation
Fully potted in urethane material with no exposure to High Voltage possible
( 171mm x 140mm x 1.0kg )
Available Options
NOTE: All “/“ options are factory installed only.
Model No.
Description
BKT
Mounting bracket
/LBO–MAXI
Lens blackout segment 180º
800/1250–DC
Clear lens dust cover
G800
Heavy duty guard
TBO–MAXI
Top lens blackout
800–FLG
Chrome flange mounting ring ( standard on DC versions,
optional on AC versions )
Replacement Parts
Model No.
Description
4001
Xenon strobe lamp
1700
Color lens ( please specify color )
801–110–BASE
120VAC power supply
801LC–BASE
120VAC power supply with AC cord set
801MBSC–BASE
120VAC power supply with magnetic mount and straight cord
801–240–BASE
240VAC power supply
801–1274–BASE
12–74VDC power supply
801MB–BASE
Architect and Engineer Specifications
The visual signaling beacon shall be Tomar model 804 or
approved equal. The light source shall be a plug-in field
replaceable single-flash xenon strobe lamp. The warning
beacon shall have a Lexan® lens and universal mount
base. The warning signal must have built-in RFI filters to
protect against radio interference and spike voltages. It
shall be polarity protected, and have a power supply fully
potted in polyurethane. The beacon shall have an 11 watt
power supply, and generate 8 joules per flash at 80 to 95
flashes per minute. Light intensity is to be 480 effective
candlepower. Voltage ranges shall be 12-74VDC, 120 VAC,
and 240VAC. Strobe light shall be designed to accept a
dome guard and mounting bracket.
12–74VDC power supply with magnetic mount and coil cord
*ECP (Effective Candlepower) is the intensity that would appear to
an observer if the light were burning steadily.
**Peak Candlepower is the maximum light intensity generated by a
flashing light during its light pulse.
29
31. VISUAL SIGNALS
8024 MINI LITE I™
Low Profile - Double or Quad Flash
Multi - Strobe
• universal mounting
• built-in RFI filters
• solid state power supply
• 10,000 hour strobe lamp
• five year warranty on power supply
• one year warranty on lamp
• available in six lens colors
The model 8024 family is a low profile, multi-flash strobe
light which can be changed by the customer from
double flash to quad flash operation. It features universal
mounting, full size 360° Lexan® lens, high efficiency
regulated solid state power supply, and heavy duty
xenon strobe lamp. DC units have polarity protection
and built-in filters to protect against radio interference
and spike voltages. AC units are designed to withstand
multiple line transient spikes of 6000V without damage.
The model 8024 strobe features a fully potted, Lexan®,
multi-purpose mounting base which is vibration and water
resistant, and has a plug-in strobe lamp and photocell
which can be activated to automatically reduce intensity
during nighttime operation.
• UL listed (AC models only)
Lens Colors
• NEMA 4X
• 750 ECP
Amber
Blue
Clear
Green
Purple
Red
Ordering Information
Please specify lens colors and model number when ordering. Available colors are Amber, Blue, Clear, Green, Purple and Red.
Model No.
Description
Voltage/Frequency
8024–110
AC strobe with 10” leads, UL listed
120VAC, 50/60Hz
8024LC–110
AC strobe with AC cord set, UL listed
120VAC, 50/60Hz
8024–240
240VAC, 50/60Hz
DC strobe with 10” leads
12 – 28VDC
8024MB–1228
DC strobe, magnetic mount and 10’ coil cord
12 – 28VDC
8024MBSC–1228
30
AC strobe with 10” leads, UL listed
8024–1228
DC strobe, magnetic mount and 10’ straight cord
12 – 28VDC
TOMAR Electronics, Inc.
2100 W. Obispo Ave.
Gilbert, AZ 85233 USA
(800) 338-3133 tel
(800) 688-6627 fax
www.tomar.com
32. 8024 Mini Lite i
801-L
Lens
5.5" dia.
800-FLG
Flange Mounting Ring
Magnetic Base Mount
4001 Xenon
Strobe Lamp
800-FLG
(optional on
AC versions)
5.25"
Base
G802
Heavy Duty Guard
BKT
Mounting Bracket
Specifications
Item
Description
Flash Rate
68 to 72 double flashes per minute
58 to 62 quad multi-flashes per minute
Light Output
750 effective candlepower (ECP)*
Voltage and Amperage
12-28VDC draws 2.2 to 2.4A @ 12V tapering to 1.2 to 1.4A @ 28V at hi intensity
120VAC draws 0.8A peak, 0.5 to 0.6A average
240VAC draws 0.8A peak, 0.5 to 0.6A average
Power Supply Output @ 240V Input
17 joules per double flash. 1,700,000 Peak Candlepower**
25 joules per quad multi-flash. 2,500,000 Peak Candlepower**
Operating Temperature
-40 C to 65 C
Size and Weight
5.25” tall x 5.5” dia. x 2.0 lbs
Encapsulation
Fully potted in urethane material with no exposure to High Voltage possible
( 133mm x 140mm x 0.9kg )
Available Options
NOTE: All “/“ options are factory installed only.
Model No.
Description
BKT
Mounting bracket
/LBO–MINILITE
Lens blackout segment 180º
802–03
Clear lens dust cover
G802
Heavy duty guard
TBO–MAXI
Top lens blackout
800–FLG
Chrome flange mounting ring
optional on AC versions )
MINILITESHIELD
Vinyl, 180º shield
( standard on DC versions,
Replacement Parts
Model No.
Description
4001
Xenon strobe lamp
801–L
Color lens ( please specify color )
824–110–BASE
120VAC power supply
824LC–110–BASE
120VAC power supply with AC cord set
824–240–BASE
240VAC power supply
824–1228–BASE
12-28VDC power supply
824MB–BASE
12–28VDC power supply with magnetic mount and coil cord
824MB–SCBASE
Architect and Engineer Specifications
The visual signaling beacon shall be Tomar model 8024 or
approved equal. The light source shall be a plug-in field
replaceable xenon strobe lamp. The beacon shall have
a field selectable double or quad flash rate of 68 to 72
double flashes per minute, or 58 to 62 quad flashes per
minute. The warning beacon shall have a Lexan® lens and
universal mount base. The DC voltage units are to have
polarity protection, and must have built-in RFI filters to
protect against radio interference and spike voltages. All
beacons must have fully potted power supply and base.
The AC units shall be designed to withstand multiple line
transient spikes of 6000V without damage. The double
flash beacon shall generate 17 joules, and the quad-flash
beacon shall generate 25 joules. Light intensity is to be 750
effective candlepower. Voltage ranges shall be 12-28VDC,
120 VAC, and 240VAC. Strobe light shall be designed to
accept a dome guard and mounting bracket.
12-28VDC power supply with magnetic mount and straight cord
*ECP (Effective Candlepower) is the intensity that would appear to
an observer if the light were burning steadily.
**Peak Candlepower is the maximum light intensity generated by a
flashing light during its light pulse.
31
33. VISUAL SIGNALS
824 MULTI STROBE
Medium Profile - Double or Quad Flash
Warning Light
• universal mounting
• built-in RFI filters
• solid state power supply
• 10,000 hour strobe lamp
• five year warranty on power supply
• one year warranty on lamp
• available in six lens colors
The model 824 family is a medium profile, multi-flash
strobe light which can be changed by the customer from
double flash to quad flash operation. It features universal
mounting, full size 360° Lexan® lens, high efficiency
regulated solid state power supply, and heavy duty xenon
strobe lamp. DC units have polarity protection and builtin filters to protect against radio interference and spike
voltages. AC units are designed to withstand multiple line
transient spikes of 6000V without damage. The model
824 strobe features a fully potted, Lexan®, multi-purpose
mounting base which is vibration and water resistant,
and has a plug-in strobe lamp and photocell which can
be activated to automatically reduce intensity during
nighttime operation.
• UL listed (AC models only)
Lens Colors
• NEMA 4X
• 1200 ECP
Amber
Blue
Clear
Green
Purple
Red
Ordering Information
Please specify lens colors and model number when ordering. Available colors are Amber, Blue, Clear, Green, Purple and Red.
Model No.
Voltage/Frequency
824–110
AC strobe with 10” leads, UL listed
120VAC, 50/60Hz
824LC–110
AC strobe with AC cord set, UL listed
120VAC, 50/60Hz
824–240
AC strobe with 10” leads, UL listed
240VAC, 50/60Hz
824–1228
DC strobe with 10” leads
12 – 28VDC
824MB–1228
DC strobe with magnetic mount and 10’ coil cord
12 – 28VDC
824MBSC–1228
32
Description
DC strobe with magnetic mount and 10’ straight cord
12 – 28VDC
TOMAR Electronics, Inc.
2100 W. Obispo Ave.
Gilbert, AZ 85233 USA
(800) 338-3133 tel
(800) 688-6627 fax
www.tomar.com
34. 824 Multi Strobe
5.5" dia.
800-FLG
Flange Mounting Ring
1700 Lens
Magnetic Base Mount
4001 Xenon
Strobe Lamp
6.75"
800-FLG
(optional on
AC versions)
Base
G800
Heavy Duty Guard
BKT
Mounting Bracket
Specifications
Item
Description
Flash Rate
68 to 72 double flashes per minute
58 to 62 quad multi-flashes per minute
Light Output
1020 effective candlepower (ECP)* (Double flash) 1200 effective candlepower (ECP)* (Quad flash)
Voltage and Amperage
12-28VDC draws 2.2 to 2.4A @ 12V tapering to 1.2 to 1.4A @ 28V at hi intensity
120VAC draws 0.8A peak, 0.5 to 0.6A average
240VAC draws 0.8A peak, 0.5 to 0.6A average
Power Supply Output @ 240V Input
17 joules per double flash. 1,700,000 Peak Candlepower**
25 joules per quad multi-flash. 2,500,000 Peak Candlepower**
Operating Temperature
-40 C to 65 C
Size and Weight
6.75” tall x 5.5” dia. x 2.2 lbs
Encapsulation
Fully potted in urethane material with no exposure to High Voltage possible
( 171mm x 140mm x 1.06kg )
Available Options
NOTE: All “/“ options are factory installed only.
Model No.
Description
BKT
Mounting bracket
/LBO–MAXI
Lens blackout segment 180º
800/1250–DC
Clear lens dust cover
G800
Heavy duty guard
TBO–MAXI
Top lens blackout
800–FLG
Chrome flange mounting ring ( standard on DC versions,
optional on AC versions )
Replacement Parts
Model No.
Description
4001
Xenon strobe lamp
1700
Color lens ( please specify color )
824–110–BASE
120VAC power supply
824LC–BASE
120VAC power supply with AC cord set
824–240–BASE
208/240VAC power supply
824–1228–BASE
12-28VDC power supply
824MB–BASE
12-28VDC power supply with magnetic mount and coil cord
824MB–SCBASE
Architect and Engineer Specifications
The visual signaling beacon shall be Tomar model 824 or
approved equal. The light source shall be a plug-in field
replaceable xenon strobe lamp. The beacon shall have
a field selectable double or quad flash rate of 68 to 72
double flashes per minute, or 58 to 62 quad flashes per
minute. The warning beacon shall have a Lexan® lens and
universal mount base. The DC voltage units are to have
polarity protection, and must have built-in RFI filters to
protect against radio interference and spike voltages. All
beacons must have fully potted power supply and base.
The AC units shall be designed to withstand multiple line
transient spikes of 6000V without damage. Light intensity
is to be 1020 effective candelas in double-flash mode, and
1200 effective candelas in quad-flash mode. Voltage ranges
shall be 12-28VDC, 120 VAC, and 240VAC. Strobe light
shall be designed to accept a dome guard and mounting
bracket.
12-28VDC power supply with magnetic mount and straight cord
*ECP (Effective Candlepower) is the intensity that would appear to
an observer if the light were burning steadily.
**Peak Candlepower is the maximum light intensity generated by a
flashing light during its light pulse.
33
35. VISUAL SIGNALS
3000 ML/RML
POWER STROBE®
Industrial Heavy Duty Warning Light
The model 3000 family of single flash strobe lights is
designed for heavy duty industrial use in steel mills and
large manufacturing plants. The ML version is a 360° self
contained unit consisting of a strobe lamp and Lexan®
lens assembly mounted on a NEMA 4 enclosed power
supply. The RML version consists of a lamp assembly and
remote power supply mounted in a NEMA 3R rain tight
enclosure.
• 250 VDC
• NEMA 4X enclosure
• optional stainless steel enclosure
• built-in RFI filters
• 10,000 hour strobe lamp
• polarity protected
The 250VDC 3000 series strobe has a flash rate of 60
flashes per minute and light intensity of 425 effective
candlepower. It is available in six lens colors (amber,
blue, clear, green, purple, and red). Each strobe contains
a built-in RFI filter to protect against harmful electrical
interference.
• solid state power supply
Lens Colors
• optional dome guard
• optional lens dust cover
Amber
Blue
Clear
Green
Purple
Red
Ordering Information
Please specify lens colors and model number when ordering. Available colors are Amber, Blue, Clear, Green, Purple and Red.
Model No.
Voltage/Frequency
Power strobe NEMA 4X
250VDC
3000/RML
34
Description
3000ML
Remote strobe NEMA 3R
250VDC
TOMAR Electronics, Inc.
2100 W. Obispo Ave.
Gilbert, AZ 85233 USA
(800) 338-3133 tel
(800) 688-6627 fax
www.tomar.com
36. 3000 ML/RML power strobe
3000 ML
Power Strobe
3000 RML
Remote Power Strobe
1700 Lens
6.75"
5.5" dia. x 6.75" high
800-CR
Clamp Ring
3001 Xenon
Strobe Lamp
10.75"
Power Supply
Enclosure
8.25" high x 6" wide x 4" deep
Specifications
Item
Description
Flash Rate
60 FPM
Light Output
425 effective candlepower (ECP)*
Voltage and Amperage
250VDC -- draws 0.07A average
Power Supply Output
15 Watts -- 10 joules per flash. 1,000,000 Peak Candlepower**
Size and Weight
ML -- 10.75” tall x 6.75”sq ( 228mm x 171mm) -- weight = 6.5 lbs. (2.94kg)
RML -- Power Supply Enclosure -- 8.25” tall x 6” wide x 4” deep ( 209mm x 153mm)
Remote beacon = 5.5”dia. x 6.75”tall (139mm x 171mm)
Total weight = 7lbs. (3.17kg)
Operating Temperature
-25ºc to 70ºc
Available Options
NOTE: All “/“ options are factory installed only.
Model No.
Description
/SS
Stainless steel enclosure
/GP
Heavy duty guard ( for ML version only )
800/1250-DC
Lens dust cover
Replacement Parts
Model No.
Description
3001
Xenon strobe lamp
1700
Color lens ( please specify color )
3002B
Power supply for 3000 series
Architect and Engineer Specifications
The visual signaling beacon shall be Tomar model 3000
series or approved equal. The light source shall be a
plug-in field replaceable single-flash xenon strobe lamp.
The warning beacon shall have a Lexan® lens and be
designed to accept a dome guard. Light intensity is to
be 425 effective candlepower. The beacon must have the
option to be mounted remotely from the power base, and
the strobe tube is to be rated at 10,000 hours lamp life.
Voltage shall be 250VDC. Strobe light shall be designed to
accept a dome guard, lens dust cover, and stainless steel
enclosure.
*ECP (Effective Candlepower) is the intensity that would appear to
an observer if the light were burning steadily.
**Peak Candlepower is the maximum light intensity generated by a
flashing light during its light pulse.
35
37. VISUAL SIGNALS
3200/3300 ML/RML
POWER STROBE®
Industrial Heavy Duty Warning Light
The model 3200 and 3300 family of single flash strobe
lights is designed for heavy duty industrial use in steel
mills and large manufacturing plants. The ML version is a
360° self contained unit consisting of a strobe lamp and
Lexan® lens assembly mounted on a NEMA 4 enclosed
power supply. The RML version consists of a lamp
assembly and remote power supply mounted in a NEMA
3R rain tight enclosure.
3200 ML with stainless
steel enclosure
• NEMA 4X enclosure
The 120 VAC 3200 and 240 VAC 3300 series strobes have
a flash rate of 85 flashes per minute and light intensity
of 425 effective candlepower. They are available in six
lens colors (amber, blue, clear, green, purple, and red).
Each strobe contains a built-in RFI filter to protect against
harmful electrical interference.
• optional stainless steel enclosure
• built-in RFI filters
• 10,000 hour strobe lamp
• polarity protected
• solid state power supply
Lens Colors
• optional dome guard
• optional lens dust cover
Amber
Blue
Clear
Green
Purple
Red
Ordering Information
Please specify lens colors and model number when ordering. Available colors are Amber, Blue, Clear, Green, Purple and Red.
Model No.
Description
Voltage/Frequency
3200ML
Power strobe NEMA 4X
120VAC
3200/RML
Remote strobe NEMA 3R
120VAC
3300ML
36
Power strobe NEMA 4
240VAC
3300/RML
Remote strobe NEMA 3R
240VAC
TOMAR Electronics, Inc.
2100 W. Obispo Ave.
Gilbert, AZ 85233 USA
(800) 338-3133 tel
(800) 688-6627 fax
www.tomar.com
38. 3200 3300 ML/RML power strobe
3200 & 3300 ML
Power Strobe
3200 & 3300 RML
Remote Power Strobe
1700 Lens
6.75"
5.5" dia. x 6.75" high
800-CR
Clamp Ring
3001 Xenon
Strobe Lamp
10.75"
Power Supply
Enclosure
8.25" high x 6" wide x 4" deep
Specifications
Item
Description
Light Output
424 effective candlepower (ECP)*
Flash Rate
85 flashes per minute @ nominal line volts to 60 FPM @ low line volts
Voltage and Amperage
120VAC -- draws 0.17A average
Power Supply Output
15 Watts -- 10 joules per flash. 1,000,000 Peak Candlepower**
Size and Weight
ML -- 10.75” tall x 6.75”sq ( 228mm x 171mm) -- weight = 6.5 lbs. (2.94kg)
RML -- Power Supply Enclosure -- 8.25” tall x 6” wide x 4” deep ( 209mm x 153mm)
Remote beacon = 5.5”dia. x 6.75”tall (139mm x 171mm)
Total weight = 7lbs. (3.17kg)
Operating Temperature
-25ºc to 70ºc
Available Options
NOTE: All “/“ options are factory installed only.
Model No.
Description
/SS
Stainless steel enclosure
/GP
Heavy duty guard ( for ML version only )
800/1250-DC
Lens dust cover
Replacement Parts
Model No.
Description
3001
Xenon strobe lamp for 3200 series
4001
Xenon strobe lamp for 3300 series
1700
Color lens ( please specify color )
3004B
Power supply for 3200 series
3009A
Power supply for 3300 series
Architect and Engineer Specifications
The visual signaling beacon shall be Tomar model number
3200 or 3300 series or approved equal. The light source
shall be a plug-in field replaceable single-flash xenon
strobe lamp. The warning beacon shall have a Lexan® lens
and be designed to accept a dome guard. The beacon
shall be in 10 joules configuration. Light intensity is to be
425 effective candlepower. The beacon must have the
option to be mounted remotely from the power base, and
the strobe tube is to be rated at 10,000 hours lamp life.
Voltage shall be 120VAC, or 240VAC. Strobe light shall be
designed to accept a dome guard, lens dust cover, and
stainless steel enclosure.
*ECP (Effective Candlepower) is the intensity that would appear to
an observer if the light were burning steadily.
**Peak Candlepower is the maximum light intensity generated by a
flashing light during its light pulse.
37
39. VISUAL SIGNALS
3200HP & 3200HP/RML
POWER STROBE®
Industrial Heavy Duty Warning Light
• NEMA 4X enclosure
• optional stainless steel enclosure
• built-in RFI filters
The model 3200HP family of single flash strobe lights is
designed for heavy duty industrial use in steel mills and
large manufacturing plants where higher light output is
required. The 3200HP version is a 360° self contained unit
consisting of a strobe lamp and Lexan® lens assembly
mounted on a NEMA 4X enclosed power supply. The RML
version consists of a lamp assembly and remote power
supply mounted in a NEMA 3R rain tight enclosure.
The 120 VAC 3200HP and 3200HP/RML series strobes
have a flash rate of 85 flashes per minute and a high
output light intensity of 600 effective candlepower. Each
strobe contains a built-in RFI filter to protect against
harmful electrical interference.
• 24,000 hour strobe lamp
• polarity protected
• solid state power supply
• optional dome guard
• optional lens dust cover
Lens Colors
• available in six lens colors
• 600 ECP
Amber
Blue
Clear
Green
Purple
Red
Ordering Information
Please specify lens colors and model number when ordering. Available colors are Amber, Blue, Clear, Green, Purple and Red.
Model No.
Voltage/Frequency
3200HP
15 joule strobe NEMA 4X
120VAC
3200HP/RML
38
Description
Remote 15 joule strobe NEMA 3R
120VAC
TOMAR Electronics, Inc.
2100 W. Obispo Ave.
Gilbert, AZ 85233 USA
(800) 338-3133 tel
(800) 688-6627 fax
www.tomar.com
40. 3200HP & 3200HP/RML power strobe
3200HP Power Strobe
3200 HP/RML
Remote Power Strobe
1700 Lens
6.75"
5.5" dia. x 6.75" high
800-CR
Clamp Ring
6001 Xenon
Strobe Lamp
10.75"
Power Supply
Enclosure
8.25" high x 6" wide x 4" deep
Specifications
Item
Description
Light Output
600 effective candlepower (ECP)*
Flash Rate
85 flashes per minute
Voltage and Amperage
120VAC -- draws 0.17A average
Power Supply Output
15 Watts -- 15 joules per flash. 1,500,000 Peak Candlepower**
Size and Weight
HP -- 10.75” tall x 6.75”sq ( 228mm x 171mm) -- weight = 6.5 lbs. (2.94kg)
HP/RML -- Power Supply Enclosure -- 8.25” tall x 6” wide x 4” deep ( 209mm x 153mm)
Remote beacon = 5.5”dia. x 6.75”tall (139mm x 171mm)
Total weight = 7lbs. (3.17kg)
Operating Temperature
-25ºc to 70ºc
Available Options
NOTE: All “/“ options are factory installed only.
Model No.
Description
/SS
Stainless steel enclosure
/GP
Heavy duty guard ( for ML version only )
800/1250-DC
Lens dust cover
Replacement Parts
Model No.
Description
6001
Xenon strobe lamp
1700
Color lens ( please specify color )
3200HP–PSA
Power supply for 3200HP & 3200HP/RML
Architect and Engineer Specifications
The visual signaling beacon shall be Tomar model number
3200 or 3300 series or approved equal. The light source
shall be a plug-in field replaceable single-flash xenon
strobe lamp. The warning beacon shall have a Lexan® lens
and be designed to accept a dome guard. The beacon
shall be in 10 joules configuration. Light intensity is to be
425 effective candlepower. The beacon must have the
option to be mounted remotely from the power base, and
the strobe tube is to be rated at 24,000 hours lamp life.
Voltage shall be 120VAC. Strobe light shall be designed to
accept a dome guard, lens dust cover, and stainless steel
enclosure.
*ECP (Effective Candlepower) is the intensity that would appear to
an observer if the light were burning steadily.
**Peak Candlepower is the maximum light intensity generated by a
flashing light during its light pulse.
39
41. VISUAL SIGNALS
7120R
POWER STROBE®
Industrial Heavy Duty Warning Light
Tomar model 7120R is a double-flash strobe designed
for heavy duty industrial use in steel mills and large
manufacturing plants where very high light output is
required. At 40 flashes per minute and 2000 effective
candlepower it is Tomar’s brightest industrial visual
signaling device. It features a remote mounted solid
state power supply in a NEMA 4 JIC box and a 1/2” pipe
mounted hi-output strobe light head with a 360° Lexan®
lens and a long life (24,000 hour) strobe tube.
• NEMA 4X enclosure
• 2000 effective candle power
• 24000 hour strobe tube
• built-in synchronizing flash circuit
• built-in RFI filters
The 7120R features a built-in synchronizing flash circuit
Each unit contains a built-in RFI filter to protect against
harmful electrical interference.
• solid state power supply
Lens Colors
• two year warranty on power supply
• one year warranty on lamp
Amber
Blue
Clear
Green
Purple
Red
Ordering Information
Please specify lens colors and model number when ordering. Available colors are Amber, Blue, Clear, Green, Purple and Red.
Model No.
Voltage/Frequency
7120R
40
Description
High power remote strobe NEMA 4X
120VAC
TOMAR Electronics, Inc.
2100 W. Obispo Ave.
Gilbert, AZ 85233 USA
(800) 338-3133 tel
(800) 688-6627 fax
www.tomar.com
42. 7120R Power strobe
Remote Power Strobe
8.5"
1700 Lens
5.75"
800-CR
Clamp Ring
6"
6"
6001 Xenon
Strobe Lamp
3.75"
Power Supply
Enclosure
Specifications
Item
Description
Light Output
2000 effective candlepower (ECP)*
Flash Rate
40 DFPM double flashes per minute
Voltage and Amperage
120VAC -- draws 0.4A average
Power Supply Output
26 Watts -- 20 joules per flash. 2,000,000 Peak Candlepower**
Size and Weight
Power Supply Enclosure = 8.25” tall x 6” wide x 4” deep ( 209mm x 153mm)
Remote beacon = 5.5”dia. x 6.75”tall (139mm x 171mm)
Total weight = 7lbs. (3.17kg)
Operating Temperature
-25ºc to 70ºc
Available Options
NOTE: All “/“ options are factory installed only.
Model No.
Description
800/1250-DC
Lens dust cover
Replacement Parts
Model No
Description
6001
Xenon strobe lamp ( models 3200HP & 7120R )
1700
Color lens ( please specify color )
Architect and Engineer Specifications
The visual signaling beacon shall be Tomar model number
7120R series or approved equal. The light source shall be
a plug-in field replaceable single-flash xenon strobe lamp.
The warning beacon shall have a Lexan® lens and be
designed to accept a dome guard. Light intensity is to be
2000 effective candlepower. The beacon must be able to
be mounted remotely from the power base, and the strobe
tube is to be rated at 24,000 hours lamp life. Voltage shall
be 120VAC. Strobe light shall be designed to accept a
dome guard and lens dust cover.
*ECP (Effective Candlepower) is the intensity that would appear to
an observer if the light were burning steadily.
**Peak Candlepower is the maximum light intensity generated by a
flashing light during its light pulse.
41
43. HAZARDOUS LOCATION
490S-T STROBE
Hazardous Location Warning Light
• Class I, Div. 2 Groups A, B, C, & D
• Class II, Div 2 Groups F & G
The model 490S-1280T and 490S-120T strobe lights
are UL listed for use in Class I & II, Division 2 hazardous
locations. Division 2 locations are defined by the NFPA as
shown below. These units have a Lexan® lens and base
and are suitable for use in NEMA 4X outdoor locations.
They may be operated in any position and feature a 1/2”
pipe mount hub.
• Class III
• NEMA 4X
• 10,000 hour strobe lamp
Lens Colors
• ten year warranty on power supply
• available in six lens colors
• UL listed
Amber
Blue
Clear
Green
Purple
Red
Ordering Information
Please specify lens colors and model number when ordering. Available colors are Amber, Blue, Clear, Green and Red.
Model No.
Voltage
490S–1280T
Hazardous location strobe
12 – 80VDC
490S–120T
42
Description
Hazardous location strobe
120VAC
TOMAR Electronics, Inc.
2100 W. Obispo Ave.
Gilbert, AZ 85233 USA
(800) 338-3133 tel
(800) 688-6627 fax
www.tomar.com
44. 490s-t strobe
3" dia.
5“
1/2” Pipe Mount
NFPA Definitions
Class I, Division 2.
A location (1) in which volatile flammable liquids or flammable gases are handled, processed or used, but in which the liquids, vapors or
gases will normally be confined within closed containers or closed systems from which they can escape only in case of accidental rupture or
breakdown of such containers or systems, or in case of abnormal operation of equipment; or (2) in which ignitable concentrations of gases or
vapors are normally prevented by positive mechanical ventilation, and which might become hazardous through failure or abnormal operation
of the ventilating equipment; or (3) that is adjacent to a Class I Division 1 location, and to which ignitable concentrations of gases or vapors
might occasionally be communicated unless such communication is prevented by adequate positive–pressure ventilation from a source of
clean air and effective safeguards against ventilation failure are provided. [See Section 500–4(b) of NFPA 70, National Electrical Code.]
Class II, Division 2.
A location in which (1) combustible dust will not normally be in suspension in the air in quantities sufficient to produce explosive or ignitable
mixtures and dust accumulations are normally insufficient to interfere with the normal operation of electrical equipment or other apparatus; or
(2) dust may be in suspension in the air as a result of infrequent malfunctioning of handling or processing equipment and dust accumulations
resulting therefrom may be ignitable by abnormal operation or failure of electrical equipment or other apparatus.
[See Section 500–5 (b) of NFPA 70, National Electrical Code.]
Specifications
Architect and Engineer Specifications
Hazardous Location visual signaling beacon shall be Tomar
model number series 490S-1280T, 490S-120T or approved
equal. The beacon shall be UL Listed Class I, Division II,
Groups A,B,C, and D; Class II, Division II, Groups F and
G; and Class III for use in specified hazardous locations as
classified by the National Electric Code. The light source
shall be a plug-in field replaceable single-flash xenon strobe
lamp. The warning signal must have built-in RFI filters to
protect against radio interference and spike voltages. It
shall be polarity protected, and have a power supply fully
potted in polyurethane. Voltage ranges shall be 12-80VDC
or 120 VAC. The warning light shall be rated NEMA 4X and
have a screw-on Lexan® lens.
Item
Description
Light Output
50 effective candlepower (ECP)*
Lamp Type
5001 Xenon strobe lamp
Lens Type
470S–L–Color ( please specify lens color )
Voltage and
Amperage
12–80VDC draws 0.4A average @ 12VDC draws tapering to
0.05A average @ 80VDC
16–24VAC draws 0.35A average
120VAC draws 0.04A average
Temperature Code
Class I T2B 260º C
Do not install where the operating temperature exceeds the
ignition temperature of the hazardous atmosphere.
Temperature Rating
–40º C to +65º C
Power Supply
Output 2.7 Watts
1.9 joules per flash. 190,000 Peak Candlepower**
Flash Rate
60 to 80 flashes per minute
*ECP (Effective Candlepower) is the intensity that would appear to
an observer if the light were burning steadily.
Size and Weight
5” tall x 3” dia. x 0.6 lbs
**Peak Candlepower is the maximum light intensity generated by a
flashing light during its light pulse.
Encapsulation
Fully potted in urethane material with no exposure to
High Voltage possible
( single flash )
( 127mm x 76mm x 0.27kg )
43
45. HAZARDOUS LOCATION
4375 STROBE
Hazardous Location Warning Light
• Class I, Div. 2 Groups A, B, C, & D
• 10,000 hour strobe lamp
• two year warranty on power supply
• one year warranty on lamp
• available in five lens colors
The Model 4375 hazardous location light features a high
output xenon strobe tube providing 80 Effective and
800,000 Peak candlepower. It is constructed and listed
to UL standard ANSI/ISA 12.12.01-2013 for nonincendive
electrical equipment for use in Class I, Division 2 Groups
A, B, C, and D locations.
The model 4375 strobe light features a tempered glass
lens. It is NEMA 4X water tight, dust-tight, and corrosionresistant rated for use in outdoor locations. These units
may be operated in any position and feature a ¾” IPS
pendant mount.
• UL listed
Lens Colors
• CSA approved
• NEMA 4X
Amber
Blue
Clear
Green
Red
Ordering Information
Please specify lens colors and model number when ordering. Available colors are Amber, Blue, Clear, Green and Red.
Model No.
Voltage
4375–120
Hazardous location AC strobe
120 – 240VAC
4375–1274
44
Description
Hazardous location DC strobe
12 – 74VDC
TOMAR Electronics, Inc.
2100 W. Obispo Ave.
Gilbert, AZ 85233 USA
(800) 338-3133 tel
(800) 688-6627 fax
www.tomar.com
46. 4375 Strobe
5.4" dia.
4375-L
Lens
2001 Xenon
Strobe Lamp
8.25"
Power Supply
Base
NFPA Definitions
Class I, Division 2.
A location (1) in which volatile flammable liquids or flammable gases are handled, processed or used, but in which the liquids, vapors or
gases will normally be confined within closed containers or closed systems from which they can escape only in case of accidental rupture or
breakdown of such containers or systems, or in case of abnormal operation of equipment; or (2) in which ignitable concentrations of gases or
vapors are normally prevented by positive mechanical ventilation, and which might become hazardous through failure or abnormal operation
of the ventilating equipment; or (3) that is adjacent to a Class I Division 1 location, and to which ignitable concentrations of gases or vapors
might occasionally be communicated unless such communication is prevented by adequate positive–pressure ventilation from a source of clean
air and effective safeguards against ventilation failure are provided.
[See Section 500–4(b) of NFPA 70, National Electrical Code.]
Specifications
Item
Description
Light Output
80 effective candlepower (ECP)*
Lamp Type
2001 Xenon strobe lamp
Lens Type
4375–L–Color ( please specify lens color )
Voltage and Amperage
12–74VDC draws 1.2A @ 12VDC draws 0.33A @ 74VDC
120/240VAC draws 0.2A @ 120VAC (50/60Hz) draws 0.6A @
240VAC (50/60Hz)
Temperature Code
Class I, T2, 300º C
Do not install where the operating temperature exceeds the
ignition temperature of the hazardous atmosphere.
Temperature Rating
–40º C to +55º C
Power Supply
Output 15 Watts
8 joules per flash. 800,000 Peak Candlepower**
Flash Rate
80 flashes per minute ± 10%
Size and Weight
8.5” tall x 5.4” dia. x 3.2 lbs
( single flash )
Architect and Engineer Specifications
Hazardous Location visual signaling beacon shall be Tomar
model number series 4375 or approved equal. The beacon
shall be UL Listed Class I, Division II, Groups A,B,C, and
D; for use in specified hazardous locations as classified
by the National Electric Code. The light source shall be a
plug-in field replaceable single-flash xenon strobe lamp.
The warning signal must have built-in RFI filters to protect
against radio interference and spike voltages. Voltage
ranges shall be 12-74VDC and 120-240VAC. The warning
light shall be rated NEMA 4X and have a tempered glass
lens.
*ECP (Effective Candlepower) is the intensity that would appear to
an observer if the light were burning steadily.
**Peak Candlepower is the maximum light intensity generated by a
flashing light during its light pulse.
( 215mm x 137mm x 1.45kg )
45
47. HAZARDOUS LOCATION
2000XL Series
Hazardous Location Non-Metallic
Compact LED Warning Light
Tomar Electronics model 2000XL series is a compact
Hazardous Location LED warning light engineered to
perform in the harshest environments. Constructed
of 30% glass-filled thermoset polyester it is particularly
well-suited for installations in corrosive, wet NEMA 4X
harsh environments, and hazardous locations. This high
strength FRP material is resistant to the corrosive effects
of most chemicals, hydrocarbons and solvents.
Shown with optional flange mount & dome guard
• Class I, Division 2 Groups A, B, C, & D
• Class I, Zone 2, Groups IIC, IIB, IIA
• Class II Division 2 Groups F & G; Class III
• CSA Enclosure Type 4X, IP66
• NEMA 4X, Marine Rated
• 5-year warranty
• Sealed construction
• 5 LED Colors – Amber, Blue, Green,
Red, White
• Top Blackout Cap
Typical applications include manufacturing plants,
chemical and petrochemical processing facilities, sewage
treatment plants, off-shore and dockside installations,
agricultural, commercial, industrial, mining and marine
facilities.
Totally non-metallic these warning lights are fully sealed
for NEMA 4X capability in any mounting configuration
– base up, down or side positions. Their compact design
makes them ideally suited where space consideration may
be an issue.
Unique mounts allow for Pendant, Flange (Ceiling), or
Wall mount installations. Buy just the mounting style
you need, or install directly onto approved panel surface.
Optional dome guard is also available.
Available in either Flashing or Steady-burn mode, this
model will operate over a wide AC and DC input voltage
range. The DC version operates from 10-100 VDC, and
the AC version from 85 – 265 VAC.
to the following standards:
• UL 1598 Standard for luminaires
• UL 1598A Marine luminaires
• UL 844 Standard for lighting fixtures forhazardous locations
• UL 1638 Standard for visual signaling applications
• CSA C22.2 no. 137-M1981 electric luminaires for use in hazardous locations
• Enclosed and gasketed, NEMA 3, 4X, IP66
46
TOMAR Electronics, Inc.
2100 W. Obispo Ave.
Gilbert, AZ 85233 USA
(800) 338-3133 tel
Cap Colors
(800) 688-6627 fax
www.tomar.com
48. 2000XL SERIES LED
Ordering Information
Please specify LED color, and if blackout cap is required. Available LED colors are Amber, Blue, White, Green and Red.
Model No.
Description
Voltage
2024XLF
Flashing LED - body only
12-80 VDC
2124XLF
Flashing LED - body only
120 - 240 VAC
2024XLS
Steady-Burn LED - body only
12-80 VDC
2124XLS
Steady-Burn LED - body only
120 - 240 VAC
Note: Mounts and Compact Dome Guard sold separately.
Specifications
Item
Description
Lamp Type
LED
Flash Rate
75 NEOBE flashes per minute – each flash containing 7 rapid bursts of
light (approximately 560 ms “on-time” and 240 ms “off-time”
Voltage &
Amperage
200 mA @ 24 VDC Flashing / 420 mA Steady-burn
040 mA @ 120 VAC Flashing / 085 mA Steady-burn
020 mA @ 240 VAC Flashing / 045 mA Steady-burn
Temperature Range
–40º C to +65º C
Temperature Code
T6
Available Mounts & Guard Options
Item
Description
NVP
Pendant mount
NVF
Flange / Ceiling mount
NVW
Wall mount
NVGM
Architect and Engineer Specifications
Visual signaling beacon shall be Tomar Electronics model
number 2024XLF, 2124XLF, 2024XLS, or 2124XLF or
approved equal. The beacon shall be cCSA/us Listed
Class I, Division 2, Class I, Zone 2, Class II, Division 2, and
Class III for use in specified hazardous locations and / or
combustible atmospheres as classified by the National
Electric Code. The warning beacon shall be of nonmetallic glass-filled thermoset polyester construction. The
light source shall be a single high-power LED. DC voltage
range shall be from 10-100 VDC, and AC voltage range
from 85 – 265 VAC. The warning signal shall be NEMA 4X
rated in any mounting configuration – base up, down, or
side positions.
Compact dome guard
47
49. HAZARDOUS LOCATION
4000X Series
Hazardous Location Non-Metallic
Strobe Warning Light
Tomar Electronics model 4000X series is a Hazardous
Location Strobe warning light engineered to perform
in the harshest environments. Constructed of 30%
glass-filled thermoset polyester it is particularly wellsuited for installations in corrosive, wet NEMA 4X harsh
environments, and hazardous locations. This high strength
FRP material is resistant to the corrosive effects of most
chemicals, hydrocarbons and solvents.
Shown
with optional
wall mount
& dome guard
• Class I, Division 2 Groups A, B, C, & D
• Class I, Zone 2, Groups IIC, IIB, IIA
• Class II Division 2 Groups F & G; Class III
• CSA Enclosure Type 4X, IP66
• NEMA 4X, Marine Rated
• 10-year warranty on power supply
• 10,000 hour strobe tube
• Sealed construction
• 6 Lens Colors – Amber, Blue, Clear,
Green, Purple, and Red
Typical applications include manufacturing plants,
chemical and petrochemical processing facilities, sewage
treatment plants, off-shore and dockside installations,
agricultural, commercial, industrial, mining and marine
facilities.
Totally non-metallic, these warning lights are fully potted
in urethane material with no exposure to high voltage
possible. NEMA 4X rated in any mounting configuration
– base up, down or side positions.
Unique mounts allow for Pendant, Flange (Ceiling), or
Wall mount installations. Buy just the mounting style you
need. Optional dome guard is also available.
Lens Colors
to the following standards:
• UL 1598 Standard for luminaires
Amber
Blue
• UL 1598A Marine luminaires
• UL 844 Standard for lighting fixtures forhazardous locations
• UL 1638 Standard for visual signaling applications
• CSA C22.2 no. 137-M1981 electric luminaires for use in hazardous locations
• Enclosed and gasketed, NEMA 3, 4X, IP66
48
TOMAR Electronics, Inc.
2100 W. Obispo Ave.
Gilbert, AZ 85233 USA
Clear
(800) 338-3133 tel
Green
Purple
(800) 688-6627 fax
Red
www.tomar.com
50. 4000X SERIES Strobe
Ordering Information
Please specify lens colors and model number when ordering. Available colors are Amber, Blue, Clear, Green, Purple and Red.
Model No.
Description
Voltage
4024X
Xenon Strobe - body only
12-80 VDC
4120X
Xenon Strobe - body only
120 VAC
4240X
Xenon Strobe - body only
240 VAC
Note: Mounts and Dome Guards sold separately.
Specifications
Item
Description
Light Output
50 effective candlepower (ECP)*
Lamp Type
5001 Xenon Strobe tube
Flash Rate
80 flashes per minute
Voltage and
Amperage
400 mA @ 12 VDC / 200 mA @ 24 VDC
040 mA @ 120 VAC / 020 mA @ 240 VAC
Power Supply Output
2.7 Watts
1.9 joules per flash. 190,000 Peak Candlepower**
Temperature Range
–40º C to +65º C
Temperature Code
T2C
Available Mounts & Guard Options
Architect and Engineer Specifications
Visual signaling beacon shall be Tomar Electronics model
number 4024X, 4120X, or 4240X or approved equal. The
beacon shall be cCSA/us Listed Class I, Division 2, Class I,
Zone 2, Class II, Division 2, and Class III for use in specified
hazardous locations and / or combustible atmospheres
as classified by the National Electric Code. The warning
beacon shall be of non-metallic glass-filled thermoset
polyester construction. The light source shall be a plug
in field replaceable single-flash xenon strobe tube. The
signaling beacon must have built-in RFI filters to protect
against radio interference and spike voltages. It shall be
polarity protected, and have a power supply fully potted
in polyurethane. Voltage ranges shall be 12-80 VDC, 120
VAC, or 240 VAC. The warning signal shall be NEMA 4X
rated in any mounting configuration – base up, down, or
side positions and have a screw-on Lexan® lens.
Item
Description
NVP
Pendant mount
NVF
Flange / Ceiling mount
NVW
Wall mount
*ECP (Effective Candlepower) is the intensity that would appear to
an observer if the light were burning steadily.
NVG
Dome guard
**Peak Candlepower is the maximum light intensity generated by a
flashing light during its light pulse.
49
51. EXPLOSION PROOF
3150/3200/3300 BEP
Explosion Proof Warning Lights
• UL listed
• meets UL 1203 & 1638
• two year warranty on power supply
• one year warranty on lamp
• 10,000 hour strobe lamp
• available in six lens colors
• marine rated
The model 3200BEP family is designed, tested, and
certified for use in hazardous locations and hostile
environments classified by the NEC as Class I, Div. 1 &
2, Groups C & D, Class II, Div. 1 & 2, Groups E, F, G, and
Class III, Div. 1 & 2. They also meet NEMA standards 3,
4, 4X, 7CD, and 9EFG and are marine rated for use in
salt water environments. Design features include housing
made of die cast high strength copper-free aluminum
alloy with a baked powder epoxy finish, stainless steel
hardware, o-ring sealed prestressed glass globe with
double pitch acme threads for smooth assembly and ease
of maintenance, and an optional guard which need not be
removed for relamping.
• NEMA 4X
Lens Colors
• Order just the mounting style you need
– Pendant, Flange (Ceiling), or
Wall mount
Amber
Blue
Clear
Green
Purple
Red
Ordering Information
Please specify lens colors and model number when ordering. Available colors are Amber, Blue, Clear, Green and Red.
Model No.
Description
Voltage
3150BEP–FM
3/4” flange mount
12 – 74VDC
3200BEP–FM
3/4” flange mount
120VAC
3300BEP–FM
3/4” flange mount
240VAC
3150BEP–PM
3/4” pendant mount
12 – 74VDC
3200BEP–PM
3/4” pendant mount
120VAC
3300BEP–PM
3/4” pendant mount
240VAC
3150BEP–WM
3/4” wall mount
12 – 74VDC
3200BEP–WM
50
3/4” wall mount
120VAC
3300BEP–WM
3/4” wall mount
240VAC
TOMAR Electronics, Inc.
2100 W. Obispo Ave.
Gilbert, AZ 85233 USA
(800) 338-3133 tel
(800) 688-6627 fax
www.tomar.com
52. 3150 3200 3300 BEP
7.44" dia.
Pendant Mount
Flange Mount
Installed view of Guard
11.1"
Wall Mount
700-R1 Lamp
BEPG Guard
Specifications
Item
Description
Lamp Type
700–R1–COLOR ( please specify lens color )
Flash Rate
80 flashes per minute
Light Output
425 effective candlepower (ECP)*
Voltage and Amperage
12–74VDC draws 1.25A @ 12VDC tapering to 0.2A @ 74VDC
850 mA @ 18 VDC; 625 mA @ 24 VDC
170 mA @ 120 VAC; 075 mA @ 240 VAC
Power Supply
Output
13 watts standard, 11 watts for model 3150
9 joules per flash. 900,000 Peak Candlepower**
Operating
Temperature
–40º C to +65º C
Temperature Code
T6 - All voltage and temperature ranges
Size and Weight
11.1” tall x 7.44” dia. x 10.6 lbs
Available Options
Item
Description
EP–FM–1
Splice box with 1” hubs
EP–PM–1
Splice box with 1” hubs
EP–WM–1
Splice box with 1” hubs
BEPG
Architect and Engineer Specifications
Visual signaling beacon shall be Tomar model number
series 3150, 3200, 3300 or approved equal. The beacon
shall be UL Listed Class I, Division 1, Groups C and D;
Class II, Division 2, Groups E, F and G; and Class III for
use in specified hazardous locations and /or combustible
atmospheres as classified by the National Electric Code.
The light source shall be a field replaceable single-flash
xenon strobe lamp. The warning signal must have built-in
RFI filters to protect against radio interference and spike
voltages. Voltage ranges shall be 12-74VDC, 120VAC, and
240VAC. Beacon must be rated NEMA 4X, with housing
made of die cast high-strength copper-free aluminum alloy
with baked powder epoxy finish, stainless steel hardware,
O-ring sealed pre-stressed globe with double pitch acme
threads for smooth assembly and ease of maintenance.
Must include a Lexan® inner lens and tempered glass outer
dome. The housing must be designed to accommodate a
dome guard.
Guard
*ECP (Effective Candlepower) is the intensity that would appear to
an observer if the light were burning steadily.
**Peak Candlepower is the maximum light intensity generated by a
flashing light during its light pulse.
51
53. EXPLOSION PROOF
7120BEP STROBE
Super Explosion Proof
Warning Lights
• double flash high intensity
• NEMA 4X
• meets UL1203 & UL1638
• built in synchronizing circuit
• 24,000 hour strobe lamp
• two year warranty on power supply
• one year warranty on lamp
• UL listed
• marine rated
• Order just the mounting style you need
– Pendant, Flange (Ceiling), or
Wall mount
The model 7120BEP family is designed, tested, and
certified for use in hazardous locations and hostile
environments classified by the NEC as Class I, Div. 1 & 2,
Groups C & D, Class II, Div. 1 & 2, Groups E, F, G, and Class
III, Div. 1 & 2. They also meet NEMA standards 3, 4, 4X,
7CD, and 9EFG and are marine rated for use in salt water
environments. Design features include housing made of
die cast high strength copper-free aluminum alloy with a
baked powder epoxy finish, stainless steel hardware, oring sealed prestressed glass globe with double pitch acme
threads for smooth assembly and ease of maintenance, a
flash synchronizing circuit, and an optional guard which
need not be removed for relamping.
Lens Colors
Amber
Blue
Clear
Green
Purple
Red
Ordering Information
Please specify lens colors and model number when ordering. Available colors are Amber, Blue, Clear, Green, Purple and Red.
Model No.
Description
Voltage
7120BEP–FM
flange mount, 3/4” hubs
120VAC
7024BEP–FM
flange mount, 3/4” hubs
12/24VDC
7120BEP–PM
pendant mount, 3/4” hubs
120VAC
7024BEP–PM
pendant mount, 3/4” hubs
12/24VDC
7120BEP–WM
52
wall mount, 3/4” hubs
120VAC
7024BEP–WM
wall mount, 3/4” hubs
12/24VDC
TOMAR Electronics, Inc.
2100 W. Obispo Ave.
Gilbert, AZ 85233 USA
(800) 338-3133 tel
(800) 688-6627 fax
www.tomar.com