SlideShare ist ein Scribd-Unternehmen logo
1 von 16
Downloaden Sie, um offline zu lesen
Hazardous Location Solutions | for the Process Control Industry
UL • CSA • FM • ATEX • IECEx • NEPSI • INMETRO • TR CU
4
w w w. a s c o v a l v e . c o m
Global Approvals
Fluid automation equipment must operate flawlessly in haz-
ardous or explosive environments. Solenoid-operated valves
are essential components in these challenging applications.
They must comply with the strictest safety regulations while
staying up and running, cycle after cycle, year after year.
ASCO offers the world’s most comprehensive family of prod-
ucts that hold approvals from the leading global agencies —
UL, CSA, FM, ATEX, and IECEx. In addition, our valves are
inspected and certified to NEPSI in China, INMETRO in
Brazil, and TR CU in Russia. That means users can specify
highly reliable ASCO valves in their designs and be assured
they are approved for use in dangerous conditions — anywhere
in the world.
ASCO‘s global solutions for hazardous locations
include valves available in the following models:
• Standard 3-way and 4-way solenoid valves
• Direct-acting and pilot-operated solenoid valves
• Manual reset and NAMUR valves
• Rugged 316L Stainless Steel valves for
harsh environments
• Low Power Intrinsically Safe and Non-Incendive
Field Wiring solenoid valves
• Low temperature constructions down to -58˚F (-50˚C)
ASCO offers hundreds of valve constructions with various global
approvals that can be exported worldwide. Our products are
famous for their robust operator heads and extended service lives.
These products are ideal for the mission-critical demands of
power generation, chemical processing, oil, gas, and refining
applications, plus general machinery, wellhead control, mining
equipment and measuring and controlling devices.
With more than 100 specialists and over 140 distributors in the
U.S. alone, ASCO has the technical expertise that can rapidly
solve application problems and help interpret confusing product
codes and classifications. Our one-stop shopping offers time-
saving convenience and rapid fulfillment. There’s only one
source to specify; one contact number to call; one solution to
keep in inventory.
Only ASCO solenoid valves deliver the advanced designs,
top-grade materials, meticulous manufacturing, and unequaled
quality assurance that maximize durability and achieve unsur-
passed performance in hazardous and explosive environments.
If you cannot find the product you need or if you
need more detailed specifications, visit
www.ascovalve.com or call 800-972-2726.
CAUTION: Users should consult www.ascovalve.com or Catalog 35 to see complete specifications for the products selected from this catalog.
WARNING: Improper selection or use of products and related items in this catalog can cause death, serious injury, or property damage.
^ # %
1
Valve Series Type
Pipe
Size (in)
Max.
Cv (Kv)
UL or FM
√ CSA ATEX/IECEx TR CU INMETRO NEPSI Page
EV 8314 3-Way 1/8-1/4 0.2 (.17) • • • ¨ - - - 2 & 4
EV 8316 3-Way 1/4-3/4 12.5 (11) • • • ¨ - - - 2
EV 8317 3-Way 1/4 0.73 (0.63) • • • ¨ - - - 2 & 4
EV 8320 3-Way 1/4 .35 (.30) • • • ¨ - - - 3
EV 8327 3-Way 1/4 .56 (.48) • • • ¨ - - - 4
EV 8344 4-Way 1/4-1/2 2.2 (1.89) • • • ¨ - - - 2
EV 8551 3-Way
4-Way 1/4 .86 (.75) • • • ¨ - - - 3 & 5
JPIS 8314 3-Way 1/4 .06 (.05) • • • ¡ - - • 2
JPIS 8316 3-Way 1/4-3/4 5.5 (4.7) • • • ¡ - - • 2
JPIS 8317 3-Way 1/4 .73 (.63) • • • ¡ - - • 2
JPIS 8344 4-Way 1/4-3/4 5.6 (4.8) • • • ¡ - - • 2
JPIS 8551 3-Way
4-Way 1/4 .86 (.75) • • • ¡ - - • 3
Harsh Environment 8320 3-Way 1/4 .16 (.14) • • • - - - 6
NF/WSNF 8316* 3-Way 1/4-1/2 3.9 (3.4) - - • ¬ • • • 6
NF/WSNF 8320* 3-Way 1/4 .24 (.21) - - • ¬ • • • 6
NF/WSNF 8327* 3-Way 1/4 .52 (.45) - - • ¬ • • • 6 & 7
NF/WSNF 8551* 3-Way
4-Way 1/4 .87 (.75) - - • ¬ • • • 6 & 7
^ # %
¨ II 2G Ex d mb IIC T* Gb
II 2D Ex mb IIIC T** Db IP67
Ex d mb IIC T* Gb
Ex mb IIIC T** Db
ÂĄ II 1 G Ex ia IIC T6 Ga under FM10ATEX0015X
IECEx approved for: Ex ia IIC T6 Ga under IECExFMG10.0008X
ÂŹ II 2G Ex d IIC Ga T6, II2D Ex + IIIC Db
√ FM available for JPIS only
*Designated products not included in the SameDay or 5Day program have lead times of three weeks or less.
under SIRA 14 ATEX 1192X
under IECEx SIR 14.0064X
Explosion-proof
EncapsulatedCoil
IntrinsicSafety
Explosion-proof
Enclosure The majority of the items listed below are part of the
ASCO Express Shipping program which includes
ASCO SameDay and 5Day products:
Items qualifying for SameDay shipping are guaranteed to ship same business day if the order is received
before 3 P.M. EST with a maximum quantity of 25 pieces.
Items qualifying for 5Day shipping are guaranteed to ship within 5 business days with a maximum quantity of 25 pieces.
Hazardous Locations Product Offering
Hazardous Location Solutions
4
2
Pipe
Size
(in)
Orifice
Size
in (mm)
Cv Flow
Factor
(Kv=m3
/h)
Operating Pressure
Differential psi (bar)
Max.
Fluid and
Ambient
Temp. °F (˚C)
Brass Body Stainless Steel BodyAir-Inert Gas
Pressure to
Cylinder
Cylinder to
Exhaust Min. Max. Catalog Number Catalog Number
Low Power (1.4 Watt)
3/2 VALVES, UNIVERSAL OPERATION (Normally Closed or Normally Open) with NBR Disc – SIL 3 Capable, Certified by Exida ∆ ≥
1/4 1/16 (2) .08 (.07) .08 (.07) 0 150 (10) 140 (60) EV8314G300 EV8314G301 ≈
3/2 VALVES, NORMALLY CLOSED (Closed when de-energized) with NBR Disc – SIL 3 Capable, Certified by Exida ∆
1/4 5/16 (8) 1.5 (1.29) 1.5 (1.29) ƒ 150 (10) 140 (60) EV8316G301 ¬ EV8316G381 ≈
3/8 5/16 (8) 1.8 (1.37) 1.8 (1.37) ƒ 150 (10) 140 (60) EV8316G302 ¬ EV8316G382 ≈
3/8 5/8 (16) 4 (3.43) 4 (3.43) ƒ 150 (10) 140 (60) EV8316G303 ¬ -
1/2 5/8 (16) 4 (3.43) 4 (3.43) ƒ 150 (10) 140 (60) EV8316G304 ¬ EV8316G384 ≈
3/2 VALVES, UNIVERSAL (Normally Closed or Normally Open) "Quick Exhaust" with CR Diaphragm and NBR Disc
1/4 ¡ .08 (.07) .73 (.63) 5 (0.3) 150 (10) 140 (60) - EV8317G308 ¨≈
4/2 VALVES, Brass Body with NBR Disc
1/4 1/4 (6) .80 (0.69) 1 (0.86) 10 (0.7) 150 (10) 140 (60) EV8344G370 ¨ -
3/8 3/8 (10) 1.4 (1.20) 2.2 (1.89) 10 (0.7) 150 (10) 140 (60) EV8344G372 ¨ -
1/2 3/8 (10) 1.4 (1.20) 2.2 (1.89) 10 (0.7) 150 (10) 140 (60) EV8344G374 ¨ -
Intrinsically Safe
3/2 VALVES, UNIVERSAL OPERATION (NORMALLY CLOSED or NORMALLY OPEN) with NBR Disc – SIL 3 Capable, Certified by Exida ∆ ≥
1/4 1/20 (1.3) .06 (.05) .06 (.05) 0 130/105 (9/7) ≈ 149 (65) JPIS8314B300 -
3/2 VALVES, NORMALLY CLOSED (Closed when de-energized) with NBR Disc or FKM (Suffix V), as Listed – SIL 3 Capable, Certified by Exida ∆
1/4 5/16 (8) 1.5 (1.3) 1.5 (1.3) ƒ 130 (9) 149 (65) JPIS8316B301 ¬ -
3/8 5/16 (8) 1.8 (1.6) 1.8 (1.6) ƒ 130 (9) 149 (65) JPIS8316B302 ¬ -
3/8 5/8 (16) 4 (3.5) 4 (3.5) ƒ 130 (9) 149 (65) JPIS8316B303 ¬ -
1/2 5/8 (16) 4 (3.5) 4 (3.5) ƒ 130 (9) 149 (65) JPIS8316B304 ¬ -
3/4 11/16 (17) 5.5 (4.7) 5.5 (4.7) 10 (0.7) 130 (9) 149 (65) JPIS8316B374 ÂŹ -
3/2 VALVES, UNIVERSAL (NORMALLY CLOSED or NORMALLY OPEN) "Quick Exhaust" with NBR Diaphragm and NBR Disc
1/4 ¥ .06 (.07) .73 (.63) 5 (0.3) 130 (9) 149 (65) JPIS8317B307 ¨ -
4/2 VALVES, Brass Body with NBR Disc
1/4 1/4 (6) .80 (.69) 1 (.86) 10 (0.7) 130 (9) 149 (65) JPIS8344B370 ¨ -
3/8 3/8 (10) 1.5 (1.3) 2.2 (1.9) 10 (0.7) 130 (9) 149 (65) JPIS8344B372 ¨ -
1/2 3/8 (10) 1.5 (1.3) 2.2 (1.9) 10 (0.7) 130 (9) 149 (65) JPIS8344B374 ¨ -
3/4 3/4 (19) 5.2 (4.5) 5.6 (4.8) 10 (0.7) 130 (9) 149 (65) JPIS8344B376 ¨ -
¨ There are two exhaust flows in the exhaust mode (pilot and main). The pilot exhaust must be connected to the main exhaust when the air or inert gas cannot be exhausted to atmosphere.
ÂĄ For "Quick Exhaust" valves, pressure port is 1/16", exhaust port is 1/4".
ÂŹ IMPORTANT: A Minimum Operating Pressure Differential must be maintained between the pressure and exhaust ports. Supply and exhaust piping must be full area, unrestricted.
ASCO flow controls and other similar components must be installed in the cylinder lines only.
ƒ Zero minimum when valve selection gasket is in external position and proper auxiliary air pressure is applied. Minimum 15 psi (1 bar) Operating Pressure Differential when selection gasket
is in the internal position.
≈ Can be used for drynatural gas service with EV prefix.
∆ Safety manual and FMEDA (Failure Modes Effects and Diagnostic Analysis) report available.
≥ SIL 3 Capable, Certified by Exida only valid when used as Normally Closed.
Low Power & Intrinsically Safe
Low Power
• Molded one-piece solenoid with highly efficient solenoid cartridge and special low wattage coil
• Designed for use in automation of plant control systems to provide PLC compatibility and reduced battery drain
Intrinsically Safe
• Designed solely for installation in intrinsically safe or Non-Incendive Field Wiring (NIFW) areas, with properly approved
and sized limiting barriers
• Compatible with supervisory current applications
^ # %
Hazardous Location Solutions
4
3
Body
Material
Pipe
Size (in)
Orifice
Size
in (mm)
Cv Flow
Factor
(Kv=m3
/h)
Single Solenoid – SIL 3 Capable, Certified by Exida ∆
Operating Pressure Differential psi (bar)
Max. Fluid
Temp. ˚F (˚C)
Catalog
Number
Air-Inert Gas
Min. Max.
Low power - Spool Valves (1.4 Watt)
3/2, 5/2 VALVES, with NBR and PUR Seals, NAMUR Mount
Aluminum 3/2, 5/2 1/4 1/4 (6) .86 (.7) 30 (2) 150 (10) 140 (60) EV8551G301 ¨
316L Stainless Steel 3/2, 5/2 1/4 1/4 (6) .86 (.7) 30 (2) 150 (10) 140 (60) EV8551G309 ¬≈
Intrinsically Safe - Spool Valves
3/2, 5/2 VALVES, with NBR and PUR Seals, NAMUR Mount
Aluminum 3/2, 5/2 1/4 1/4 (6) .86 (.74) 35 (2.4) 130 (9) 149 (65) JPIS8551B301 ¨
316L Stainless Steel 3/2, 5/2 1/4 1/4 (6) .86 (.74) 35 (2.4) 130 (9) 149 (65) JPIS8551B309
¨ 1/8" NPT exhaust for 1/4" aluminum and brass.
ÂŹ Stainless steel construction supplied standard with EV solenoid.
≈ Can be used for drynatural gas service with EV prefix.
∆ Safety manual and FMEDA (Failure Modes Effects and Diagnostic Analysis) report available.
Low Power & Intrinsically Safe
Pipe
Size
(in)
Orifice
Size (in)
Cv Flow
Factor
(Kv=m3
/h)
Operating Pressure
Differential psi (bar) Max. Fluid
Temp. ˚F (˚C)
Brass Body Stainless Steel Body
Watt Rating/
Class of Coil
InsulationMax. AC Max. DC
Catalog Number Catalog Number
Air-Inert
Gas
Water
ƒ
Lt. Oil
@ 300
SSU
Air-Inert
Gas
Water
ƒ
Lt. Oil
@ 300
SSU AC DC AC DC
3-Way EV 8320 Series
UNIVERSAL OPERATION (Pressure at any port)
1/4 1/16 (1.6) 0.09 (0.08) 125 (9) 130 (9) 130 (9) 75 (5) 75 (5) 75 (5) 200(93) 150 (66) EV8320G172 - 10.1/F 11.6/F
1/4 3/32 (2) 0.12 (0.10) 100 (7) 100 (7) 100 (7) 60 (4) 60 (4) 60 (4) 200(93) 150 (66) EV8320G174 EV8320G200 ¬√ 17.1/F 11.6/F
1/4 1/8 (3.2) 0.25 (0.21) 50 (3) 50 (3) 50 (3) 25 (2) 25 (2) 25 (2) 200(93) 150 (66) EV8320G176 - 17.1/F 11.6/F
1/4 11/64 (4.4) 0.35 (0.30) 20 (1) 20 (1) 20 (1) 12 (1) 12 (1) 12 (1) 200(93) 150 (66) EV8320G178 - 10.1/F 11.6/F
NORMALLY CLOSED (Closed when de-energized) – PFDAVG = 6.81 x 10-4
1/4 1/16 (1.6) 0.09 (0.08) 210 (14) 225 (15) 225 (15) 160 (11) 160 (11) 160 (11) 200(93) 150 (66) EV8320G182 - 17.1/F 11.6/F
1/4 3/32 (2) 0.12 (0.10) 150 (10) 150 (10) 150 (10) 115 (8) 115 (8) 115 (8) 200(93) 150 (66) EV8320G184 EV8320G202 ¬√ 10.1/F 11.6/F
1/4 1/8 (3.2) 0.25 (0.21) 85 (6) 85 (6) 85 (6) 60 (4) 60 (4) 60 (4) 200(93) 150 (66) - EV8320G203 ¬√ 10.1/F 11.6/F
NORMALLY OPEN (Open when de-energized)
1/4 1/16 (1.6) 0.09 (0.08) 235 (16) 250 (17) 250 (17) 160 (11) 160 (11) 160 (11) 200(93) 150 (66) EV8320G192 - 17.1/F 11.6/F
1/4 3/32 (2) 0.12 (0.10) 150 (10) 140 (10) 140 (10) 100 (7) 100 (7) 100 (7) 200(93) 150 (66) EV8320G194 - 10.1/F 11.6/F
1/4 1/8 (3.2) 0.25 (0.21) 70 (5) 70 (5) 70 (5) 55 (4) 55 (4) 55 (4) 200(93) 150 (66) EV8320G196 - 10.1/F 11.6/F
ÂŹ Can be used for drynatural gas service with the EV prefix.
√ Constructions standard rated -40˚F (-40˚C) ambient temperature. EVX prefix and TPL # not required.
ƒ Water rating, CSA certified up to 232 psi (16 bar).
3-Way | General Service
8320 Series
• All NPT connections are in the valve body to allow in-line piping
• No Minimum Operating Pressure Differential required
^ # %
^ # %
Hazardous Location Solutions
4
4
Pipe
Size
(in)
Orifice
Size
in (mm)
Cv Flow
Factor
(Kv=m3
/h)
Operating Pressure Differential psi (bar)
Max. Fluid
Temp.˚F (˚C)
Brass Body
Stainless Steel
Body
Watt Rating/
Class of Coil
Insulation ÂŹMax. AC Max. DC
Catalog
Number
Catalog
NumberPress. Exh. Press. Exh. Min. ¨
Air-Inert
Gas Water
Lt. Oil ¨
@45 SSU
Air-Inert
Gas Water
Lt. Oil ¨
@45 SSU AC DC AC DC
3-Way EV 8317 Series
NORMALLY CLOSED (Closed when de-energized)
1/4 3/32 (2) 1/4 (6) .20 (.17) .73( .63) 5 (.3) ≠ 150 (10) 150 (10) 95 (7) 75 (5) 55 (4) 30 (2) 180 (82) 104 (40) EV8317G035 EV8317G036 10.1/F 11.6/F
¨ Rating for 8321 valves established with 300 SSU light oil. ≠ Minimum Operating Pressure Differential on light oil is 10 psi (0.7 bar).
Pipe
Size
(in)
Orifice
Size
in (mm)
Cv Flow
Factor
(Kv=m3
/h)
2-1
Cv Flow
Factor
(Kv=m3
/h)
1-3
Operating Pressure Differential psi (bar)
Max. Fluid
Temp.˚F (˚C) ¨
Brass Body Stainless Steel Body Watt Rating/
Class of Coil
InsulationMax. AC Max. DC
Catalog
Number
Catalog
Number
Air-Inert
Gas
Water
ÂĄ
Light Oil
@ 45 SSU
Air-Inert
Gas
Water
ÂĄ
Light Oil
@ 45 SSU AC DC AC DC
3-Way EV 8314 Series
UNIVERSAL OPERATION (Pressure at any port)
1/8 3/64 (1.2) 0.05 (0.04) 0.06 (0.05) 200 (14) 200 (14) 200 (14) 200 (14) 200 (14) 200 (14) 200 (93) 200 (93) EV8314H041 - 10.1/F 11.6/F
1/4 3/64 (1.2) 0.05 (0.04) 0.06 (0.05) 200 (14) 200 (14) 200 (14) 200 (14) 200 (14) 200 (14) 200 (93) 200 (93) EV8314H006 - 10.1/F 11.6/F
NORMALLY CLOSED (Closed when de-energized) – PFDAVG = 4.77 x 10-4
1/4 3/32 (2.4) 0.15 (0.13) 0.20 (0.17) 205 (14) 205 (14) 190 (13) 150 (10) 120 (8) 90 (6) 200 (93) 200 (93) EV8314H035 EV8314H121 10.1/F 11.6/F
¨ Maximum fluid temperature for light oil @ 45 SSU is 180˚F (82˚C). ¡ Water rating, CSA certified up to 232 psi (16 bar).
Pipe
Size
(in)
Orifice
Size
in (mm)
Cv Flow
Factor
(Kv=m3
/h)
Maximum Operating
Pressure Differential psi (bar) Max. Fluid
Temp.˚F
(˚C)
Brass Body
316 Stainless
Steel Body
Const.
Ref.
Watt Rating/
Class of Coil
Insulation
Ports
1-2
Ports
2-3 Air-Inert Gas Water
Light Oil
@ 300 SSU Catalog Number Catalog Number AC DC
3-Way EV 8327 Series
UNIVERSAL OPERATION (Pressure at any port)
1/4 1/4 (6) .49 (.42) .56 (.48) 150 (10) 150 (10) 150 (10) 176 (80) EV8327G041 – 1 12.0/F 11.6/F
1/4 1/4 (6) .49 (.42) .56 (.48) 150 (10) 150 (10) 150 (10) 248 (120) – EV8327G042 1 12.0/F 11.6/F
3-Way | General Service
8317 Series
• Designed for quick exhaust to 0 psi through the exhaust orifice
• Resilient seated poppets for tight shutoff
8314 Series
• No minimum operating pressure required
• Simplest valve for basic 3-way piloting operation, only one spring and two moving parts
8327 Series
• Designed for high flow piloting with no minimum operating pressure required
• Balanced poppet construction for high flow at minimum power levels
^ # %
Hazardous Location Solutions
4
5
Body
Material
Pipe
Size
(in)
Orifice
Size
in (mm)
Cv Flow
Factor
(Kv=m3
/h)
Single Solenoid – SIL 3 Capable, Certified by Exida ¨
Watt Rating/
Class of Coil
Insulation
Operating Pressure Differential psi (bar) Max. Fluid
Temp.˚F (˚C)
Catalog
Number
Air-Inert Gas
Min. Max. AC Max. DC AC DC AC DC
3-Way EV 8551 Series - NAMUR Mount Spool Valves
316L Stainless Steel 3/2, 5/2 1/4 1/4 (6) .86 (.75) 30 (2) 150 (10) 120 (8.2) 140 (60) 120 (48) EV8551G409 10.1/F 11.6/F
¨ Safety manual and FMEDA (Failure Modes Effects and Diagnostic Analysis) report available.
Pipe
Size
(in)
Orifice
Size
in (mm)
Cv Flow
Factor
(Kv=m3
/h)
Operating Pressure Differential psi (bar)
Max. Fluid
Temp.˚F (˚C) Brass Body
Watt Rating/
Class of Coil
InsulationMax. AC Max. DC
Press. Exh. Inlet Exh. Min.
Air-Inert
Gas Water
Lt. Oil @
50 SSU
Air-Inert
Gas Water
Lt. Oil @
50 SSU AC DC Catalog Number AC DC
4-Way EV 8345 Series
SINGLE SOLENOID
1/4 1/16 (2) 3/32 (2) .09 (.08) .09 (.08) 10 (.07) 150 (10) 150 (10) 150 (10) 100 (7) 100 (7) 100 (7) 180 (82) 104 (40) EV8345G001 10.1/F 11.6/F
4-Way | General Service
3-Way | General Service
8551 Series
• Unique spool design combines hard T-seals and flexible o-rings which provides bubble-tight shutoff, resistance to
dirt and sticking, and multimillion cycle life controlling air or inert gas
8345 Series
• Compact 4-way valves for low flow applications
^ # %
^ # %
Hazardous Location Solutions
4
6
Pipe
Size
in (mm)
Orifice
Size
in (mm)
Cv Flow
Factor
(Kv=m3
/h)
Operating Pressure Differential psi (bar)
Ambient Temp. °F (°C)
Brass Stainless
Watt Rating/
Class of
Coil Insulation
Min.
Max. AC Max. DC
Air-Inert
Gas Water
Light Oil
@ 300
SSU
Air-Inert
Gas Water
Light Oil
@ 300
SSU Min Max. AC Max. DC AC DC
3/2 VALVES, UNIVERSAL, DIRECT ACTING, BALANCED POPPET
1/4 0.22 (5.7) 0.52 (0.45) 0 (0) 145 (10) 145 (10) - 145 (10) 145 (10) - -4 (-20) 248 (120) 248 (120) NF8327B101 ¨ WSNF8327B102 3.7 3.6
1/4 0.22 (5.7) 0.52 (0.45) 0 (0) 145 (10) 145 (10) - 145 (10) 145 (10) - -58 (-50) 140 (60) 140 (60) NF8327B111 ÂŹ WSNF8327B112 3.7 3.6
¨ Fluoroelastomer sealings and poppets.  Fluorosilicone sealings and poppets.
3/2 VALVES, DIRECT ACTING, UNIVERSAL
1/4 0.13 (3.2) 0.24 (0.21) 0 (0) 49 (3.4) 49 (3.4) 50 (3.4) 25 (1.7) 25 (1.7) 25 (1.4) 32 (0) 126 (52) 104 (40) NF8320B176 WSNF8320A201 17.1 11.6
1/4 0.09 (2.4) 0.12 (0.1) 0 (0) 102 (7) 102 (7) - 58 (4) 58 (4) - -4 (-20) 194 (90) 194 (90) NF8320B174 WSNF8320A200 16.7 11.2
3/2 VALVES, DIRECT ACTING, NORMALLY CLOSED
1/4 0.09 (2.4) 0.12 (0.1) 0 (0) 145 (10) 145 (10) - 116 (8) 116 (8) - -4 (-20) 194 (90) 194 (90) NF8320A184 WSNF8320A202 10.5 11.2
3/2 VALVES, DIRECT ACTING, NORMALLY OPEN
1/4 0.09 (2.4) 0.12 (0.1) 0 (0) 73 (5) 73 (5) - 58 (4) 58 (4) - -4 (-20) 194 (90) 194 (90) NF8320A196 WSNF8320A205 10.5 11.2
1/4 0.09 (2.4) 0.12 (0.1) 0 (0) 145 (10) 145 (10) - 102 (7) 102 (7) - -4 (-20) 194 (90) 194 (90) NF8320A194 WSNF8320A204 10.5 11.2
3/2 VALVES, ZERO MINIMUM, NORMALLY CLOSED
1/4 0.31 (8) 1.5 (1.3) 0 (0) √ 145 (10) - - 116 (8) - - -4 (-20) 176 (80) 176 (80) NF8316A001 ƒ WSNF8316A081V ≈ 10.5 11.2
1/4 0.31 (8) 1.5 (1.3) 0 (0) √ 145 (10) - - 145 (10) - - -4 (-20) 140 (60) 140 (60) NF8316A301 ƒ WSNF8316A381V ≈ 1.8 1.8
3/8 0.31 (8) 1.7 (1.5) 0 (0) √ 145 (10) - - 116 (8) - - -4 (-20) 176 (80) 176 (80) NF8316A002 ƒ WSNF8316A082V ≈ 10.5 11.2
3/8 0.31 (8) 1.7 (1.5) 0 (0) √ 145 (10) - - 145 (10) - - -4 (-20) 140 (60) 140 (60) NF8316A302 ƒ WSNF8316A382V ≈ 1.8 1.8
3/8 0.63 (16) 3.9 (3.4) 0 (0) √ 145 (10) - - 116 (8) - - -4 (-20) 176 (80) 176 (80) NF8316A003 ƒ - 10.5 11.2
3/8 0.63 (16) 3.9 (3.4) 0 (0) √ 145 (10) - - 145 (10) - - -4 (-20) 140 (60) 140 (60) NF8316A303 ƒ - 1.8 1.8
1/2 0.63 (16) 3.9 (3.4) 0 (0) √ 145 (10) - - 116 (8) - - -4 (-20) 176 (80) 176 (80) NF8316A004 ƒ WSNF8316A084V ≈ 10.5 11.2
1/2 0.63 (16) 3.9 (3.4) 0 (0) √ 145 (10) - - 145 (10) - - -4 (-20) 140 (60) 140 (60) NF8316A304 ƒ WSNF8316A384V ≈ 1.8 1.8
√ Zero minimum when valve selection gasket is in external position and proper auxiliary air pressure is applied. Minimum 15 psi (1 bar) operating pressure differential when selection gasket is in the internal position.
ƒ Nitrile seal materials. ≈ Fluoroelastomer seal materials.
3/2 VALVES, PILOT OPERATED, SPOOL TYPE, NORMALLY CLOSED
1/4 0.24 (6) 0.87 (0.75) 30 (2) 145 (10) - - 145 (10) - - -13 (-25) 140 (60) 140 (60) NF8551B405 ≤ 10.5 11.2
1/4 0.24 (6) 0.87 (0.75) 30 (2) 145 (10) - - 145 (10) - - -40 (-40) 176 (80) 176 (80) - WSNF8551A413 10.5 11.2
≤ Aluminum body
3 and 4-Way ATEX Pilot Valves
The following valves are not part of the ASCO Express Shipping program.
Typical lead times are three weeks or less. Please consult the factory for specific lead times.
• Worldwide approvals for use in potentially explosive atmospheres: ATEX, IECEx, INMETRO, TR CU, and NEPSI
• Enclosure provided with a 1/2 NPT threaded entry hole for a broad range of cable glands
• IP67 ingress protection
• Operator can be rotated through 360° to select the most favorable position for cable entry
3-Way ATEX Pilot Valves
Pipe
Size
(in)
Orifice
Size
in (mm)
Cv Flow
Factor
(Kv=m3
/h)
Operating Pressure
Differential psi (bar)
Ambient
Temp. °F (°C) Stainless Steel Body
Wattage Rating/
Coil Insulation ClassAir/Natural Gas
Min. Max. Catalog Number ÂĄPressure Exhaust Pressure Exhaust Min. Max. 12 or 24 VDC
NORMALLY CLOSED (Closed when de-energized)
1/4 1/16 (1.6) 3/32 (2.4) 0.08 (0.07) 0.16 (0.14) 0 150 (10) ¨ -4 (-20) 122 (50) EF8320A511 1.3/F
¨ Light Oil @ 300 SSU Max. Pressure 125 psi (8.6 bar). ¥ SIL 3 Capable, Certified by Exida
Harsh Environment
• Designed for harsh, hazardous environments, including offshore applications
• Low power consumption suitable for solar panels and PLC/DCS applications
^ # %
|
Hazardous Location Solutions
4
7
Pipe
Size
in (mm)
Orifice
Size
in (mm)
Cv Flow
Factor
(Kv=m3
/h)
Operating Pressure Differential psi (bar)
Ambient Temp. °F (°C)
Aluminum Stainless
Watt Rating/
Class of
Coil Insulation
Min.
Max. AC Max. DC
Air-Inert
Gas Water
Light Oil
@ 300
SSU
Air-Inert
Gas Water
Light Oil
@ 300
SSU Min
Max.
AC
Max.
DC AC DC
5/2 VALVES, PILOT OPERATED, SPOOL TYPE, SINGLE SOLENOID
1/4 0.24 (6) 0.87 (0.75) 0 (0) 145 (10) - - 145 (10) - - -13 (-25) 140 (60) 140 (60) NF8551B417 - 10.5 11.2
1/4 0.24 (6) 0.87 (0.75) 0 (0) 145 (10) - - 145 (10) - - -13 (-25) 140 (60) 140 (60) NF8551B317 - 1.9 1.9
1/4 0.24 (6) 0.87 (0.75) 0 (0) 145 (10) - - 145 (10) - - -40 (-40) 176 (80) 176 (80) - WSNF8551A421 10.5 11.2
1/4 0.24 (6) 0.87 (0.75) 0 (0) 145 (10) - - 145 (10) - - -40 (-40) 176 (80) 176 (80) - WSNF8551A321 1.9 1.9
5/2 VALVES, PILOT OPERATED, SPOOL TYPE, DUAL SOLENOID
1/4 0.24 (6) 0.87 (0.75) 0 (0) 145 (10) - - 145 (10) - - -13 (-25) 140 (60) 140 (60) NF8551B418 10.5 11.2
1/4 0.24 (6) 0.87 (0.75) 0 (0) 145 (10) - - 145 (10) - - -40 (-40) 176 (80) 176 (80) - WSNF8551A422 10.5 11.2
1/4 0.24 (6) 0.87 (0.75) 0 (0) 145 (10) - - 145 (10) - - -40 (-40) 140 (60) 140 (60) - WSNF8551A322 1.9 1.9
5/2 VALVES, PILOT OPERATED, SPOOL TYPE, SINGLE SOLENOID, NAMUR
1/4 0.24 (6) 0.87 (0.75) 0 (0) 145 (10) - - 145 (10) - - -13 (-25) 140 (60) 140 (60) NF8551B401 - 10.5 11.2
1/4 0.24 (6) 0.7 (0.6) 0 (0) 145 (10) - - 145 (10) - - -40 (-40) 176 (80) 176 (80) - WSNF8551A409 10.5 11.2
1/4 0.24 (6) 0.7 (0.6) 0 (0) 145 (10) - - 145 (10) - - -40 (-40) 176 (80) 176 (80) - WSNF8551A309 1.9 1.9
Pipe
Size
in (mm)
Orifice
Size
in (mm)
Cv Flow
Factor
(Kv=m3
/h)
Operating Pressure Differential psi (bar)
Ambient
Temp. °F (°C)
Brass Stainless
Watt Rating/
Class of
Coil Insulation
Min.
Max. AC Max. DC
Air-Inert
Gas Water
Light Oil
@ 300
SSU
Air-Inert
Gas Water
Light Oil
@ 300
SSU Min
Max.
AC
Max.
DC AC DC
3/2 VALVES, MANUAL RESET, NO VOLTAGE RELEASE
1/4 0.22 (5.7) 0.52 (0.45) 0 (0) 145 (10) 145 (10) - 145 (10) 145 (10) - -4 (-20) 248 (120) 248 (120) NF8327B121 WSNF8327B122 3.7 3.6
1/4 0.22 (5.7) 0.52 (0.45) 0 (0) 145 (10) 145 (10) - 145 (10) 145 (10) - -40 (-40) 104 (40) 104 (40) NF8327B171 WSNF8327B172 3.7 3.6
4-Way ATEX Pilot Valves
3-Way ATEX Pilot Valves | Manual Reset
EV Explosion-proof Encapsulated Coil
JPIS Intrinsically Safe
NF Aluminum Epoxy Coated
WSNF 316L Stainless Steel
Refer to Specification Section AC 120/60, 110/50,
230/50
DC 24V
EV 8316G301 24/DC
Enclosure Base Catalog Number Voltage
ATEX, IECEx
NF Aluminum Epoxy Coated
WSNF 316L Stainless Steel
Refer to Specification Section AC 230/50
DC 24V
22560 NEPSI
26350 INMETRO
18460 TR CU
WSNF X 225608327B212 24/DC
Enclosure Base Catalog Number VoltageApproval
NEPSI, INMETRO, and TR CU (ATEX, IECEx Standard)
How to Order
The following valves are not part of the ASCO Express Shipping program.
Typical lead times are three weeks or less. Please consult the factory for specific lead times.|
8
DEFINITION OF A LOCATION WHERE A POTENTIALLY EXPLOSIVE ATMOSPHERE MAY OCCUR
The classification of an installation into distinct zones has two objectives (according to ATEX 1999/92/EC):
- To define the categories of equipment used in the zones indicated, provided they are suitable for gases, vapours or mists and/or dusts.
- To classify hazardous places into zones to prevent ignition sources and be able to select the correct electrical and non-electrical
equipment accordingly. The zones are defined on the basis of the occurrence of explosive gaseous or dusty atmospheres.
GAS GROUPS
Group II: Equipment intended for use in places with an explosive gas atmosphere other than mines susceptible to firedamp.
Group I: Equipment intended for use in mines susceptible to firedamp.
Zone Category (ATEX 94/9/EC) Presence of explosive atmospheres
zone 0 1 G¨
Continuous, frequent or for long periods
Group II zone 1 2 G Intermittent in normal operation (likely)
zone 2 3 G Occasional or for short periods (never in normal operation)
Group I M1¨
Presence (methane, dust)
(mines) M2 Risk of presence (methane, dust)
DUST GROUPS (according to the fifth edition, IEC 60079-0, 2011 (EN 60079-0, 2012)ÂĄ
)
Group III: Equipment intended for use in places with an explosive dust atmosphere other than mines susceptible to firedamp.
Zone Category (ATEX 94/9/EC) Presence of explosive atmospheres
zone 20 1 D ¨
Continuous, frequent or for long periods (air/cloud of combustible dust)
Group III zone 21 2 D Intermittent in normal operation
zone 22 3 D Occasional or for short periods
Equipment Group
II Industrial
Equipment Category
2 High Protection
Suitability of Use
G Gas
Mark for Explosion Proof Protection Method
d Flameproof
Gas/Dust Group
IIC Hydrogen/Acetylene
Equipment Protection Level
Gb High Protection (Gas)
Temperature Code
T3 200˚C
T4 135˚C
T5 100˚C
T6 85˚C
II 2 G Ex IIC
Encapsulation
Gasses and Vapors, Dust
mb
Encapsulation
Gasses and Vapors, Dust
mbd T3...T6
Temperature Code
T200
T135
T100
T85
T85
Gb
Equipment Group
II Industrial
Equipment Category
2 High Protection
Suitability of Use
D Dust
Mark for Explosion Proof Protection By Enclosure
tb Dust
Gas/Dust Group
IIIC Conductive Dust
Equipment Protection Level
Db High Protection (Dust)
Temperature Code
6 Dust Tight
7 Temporary Submersion
II 2 D Ex IIICtb IP67Db
Safety Code Explained
¨
G = gas ; D = dust ; M = mines
ÂĄ
Including IEC 61241-0 (dusts)
Reference Guide
Reference Guide
4
9
Typical Gas/Dust Group
Gas
Propane IIA
Ethylene IIB
Acetylene IIC
Dust
Combustible Fyings IIIA
Non-Conductive Dust IIIB
Conductive Dust IIIC
Level of Protection Against Solid Objects,
Materials or Dust
Level of Protection Against Water
and Other Liquids
0 No protection 0 No protection
1 Protected against solid objects down to 50 mm 1 Protection against vertically fall- ing drops of water (e.g. conden- sation)
2 Protected against solid objects down to 12 mm 2 Protection against direct sprays of water up to 15 degrees from vertical
3 Protected against solid objects down to 2.5 mm 3 Protection against direct sprays of water up to 60 degrees from vertical
4 Protected against solid objects down to 1 mm 4
Protection against water sprayed from all directions - limited in- gress
permitted
5
Protected against dust, limited ingress
(no harmful deposits)
5
Protection against low pressure jets of water from all directions - limited
ingress permitted
6 Totally protected against dust 6
Protection against low pressure jets of water, limited ingress per- mitted
(e.g. ship deck)
7 Protected against the effect of immersion between 6 in. / 15 cm and 3 ft / 1m
8 Protected against long periods of immersion under pressure
Gas & Dust Groups Ingress Protection (i.e. IP67)
Equipment
Group
Equipment
Category
Equipment
Protection Level
(EIC)
Level of
Protection
Hazard Zone (Flammable Material Present)
Gas Dust
0 - 20
(Continuosly)
1 - 2
(Intermittently)
2 - 22
(Abnormally)
I
M 1 Ma Very High - - Operable in Ex atmosphere
M 2 Mb High - - De-energized in Ex atmosphere
II
1
Ga Very High G - 0 1 2
Da Very High - D 20 21 22
2
Gb High G - - 1 2
Db High - D - 21 22
3
Gc Normal G - - - 2
Dc Normal - D - - 22
Groups, Categories, & Zones (i.e. II 2 G Ex d IIC Gb T6 … T4)
Flammable /
Combustable
Substance
Protection
Symbol
Zones
Description0 1 2
Gas
d l l Flameproof Enclosure
p l l Pressurised enclosure
q l l Powdery filling
o l l Immersion
e l l Increased safety
ia/ib/ic l l l Intrinsically safety
n l Non incendiaire
ma/mb/mc l l l Encapsulation
Dust
ia l Intrinsically safety
tD l Flameproof Enclosure
mD l l Encapsulation
Protection Methods
Reference Guide
4
10
CLASSIFICATION OF GASES INTO EXPLOSION GROUPS
Group I: Electrical equipment intended for use in the underground parts of mines, and to those parts of surface installations
of such mines, likely to become endangered by firedamp and/or combustible dust.
Group II: Electrical equipment intended for use in other places likely to become endangered by explosive atmospheres
(surface industries).
¨ Temperature of a hot surface able to ignite a gas mixture.
The ignition temperature of the gas mixture must be higher than the maximum surface temperature. In practice, a 10 to 20% safety margin is observed
between the ignition temperature and the rated nameplate temperature.
The ignition temperature of a cloud of dust is generally between 300 and 700°C. At 150 to 350°C, the ignition temperature of a layer of dust is far below
that of a dust cloud. A burning dust layer can initiate a dust explosion if brought in contact with a combustible dust cloud, so these values must be
taken into account to limit the risk.
CLASSIFICATION OF DUSTS INTO EXPLOSION GROUPS (according to the fifth edition, IEC 60079-0, 2011)
Group III: Electrical equipment intended for use in places with an explosive dust atmosphere other than mines susceptible
to firedamp.
Group III is subdivided into IIIA (combustible flyings), IIIB (non-conductive dust) and IIIC (conductive dust).
Combustible dust: Finely divided solid particles, 50 Âľm or less in nominal size, which may be suspended in air, may settle
out of the atmosphere under their own weight, may burn or glow in air, and may form explosive mixtures with air at atmos-
pheric pressure and normal temperatures.
Non-conductive dust: Combustible dust with electrical resistivity greater than 103 Ί.m
Conductive dust: Combustible dust with electrical resistivity equal to or less than 103 Ί.m
¨ The maximum surface temperature must be identified and suitable for the specified type of dust present (equipment marked for zone 21).
In order to prevent the ignition of dusty atmospheres, the maximum surface temperature needs to be limited. It must not exceed:
- 2/3 of the auto-ignition temperature of the specified cloud of dust,
- the auto-ignition temperature of a 5 mm layer of dust minus 75°C.
Groups Gas Ignition Temperature (°C) ¨
Temperature Class
T1 T2 T3 T4 T5 T6
I methane (redamp)
II
A
acetone 540 •
acetic acide 485 •
ammonia 630 •
ethane 515 •
methylene chloride 556 •
methane (CH4) 537 •
carbon monoxyde 605 •
propane 470 •
n-butane 365 •
n-butyl 370 •
n-hexane 240 •
acetaldehyde 140 •
ethyl ether 160 •
ethyl nitrite 90 •
B
ethylene 425 •
ethyl oxyde 429-440 •
hydrogen sulfide 270 •
C
acetylene (C2H2) 305 •
carbon disulphide (CS2) 102 •
hydrogen (H2) 560 •
Combustible dust Ignition Temperature (˚C) ¨ Self-ignition temperature of dust layers (˚C) ¨
Starch 440 290
Aluminium 530 280
Cotton 560 350
Cereals 420 290
Magnesium 610 410
Soybean 500 245
Sulphur 280 280
Tobacco 450 300
Reference Guide
4
11
Valve Parts in Contact with Fluid
Valve Series
8262 8320 8327 8316 8551 / 8553
Body 303 SS BR/303 SS BR/316 SS BR 316 SS AL/BR 316 SS
Core and Plugnut 430F SS 430F SS 430F SS 430F SS 430F SS 430F SS 430F SS
Core Tube 303 SS 303 SS 303 SS 303 SS 303 SS 303 SS 303 SS
Disc and Seals Sealings & Poppet (8327) NBR NBR FPM/VMQ/FVMQ NBR NBR NBR/PUR VMQ/PUR
Diaphragms (8316) - - - NBR FPM
Disc Holder & Core Guide - CA - - - POM POM
Springs 303 SS 303 SS 303 SS 303 SS 303 SS 303 SS 303 SS
Shading Coil SILVER Copper/Silver - Copper Silver - -
Rider Ring - - PTFE PTFE PTFE PTFE PTFE
ATEX Wetted Parts
Enclosure Type NF WSNF JPIS EV
Conduit 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT
Solenoid Enclosure Chromated Aluminum epoxy coated 316L Stainless steel Aluminum Epoxy Encapsulated
Bonnet Steel (zinc plated) Stainless steel (nickel plated) 430F Stainless steel 416 Stainless steel
Core, Core Tube & Plugnut 430F Stainless Steel 430F Stainless steel 430F Stainless steel
Shading coil Copper or silver Not Applicable Copper or silver
Nameplate Stainless Steel 304 Stainless steel 304 Stainless steel
Electrical Connection Screw Terminals Screw Terminals Lead Wires
Fasteners and Screws Stainless steel 316 Stainless Steel Not Applicable
Materials of construction
TEMPERATURE CLASS
The temperature classification is based on the maximum surface temperature of equipment. That is the highest temperature
any part of or the entire surface of an electrical device can reach under the most unfavorable operating conditions capable
of igniting a surrounding explosive atmosphere.
Group I: Temperature ≤ 150°C or ≤ 450°C according to coal dust accumulation on equipment
Group II: Equipment must be classified and marked:
- preferably with the temperature class (T classification)
- defined by the surface temperature or, limited to the specified flammable gases or dusts for which it is approved,
if necessary (and marked accordingly).
Temperature Class Maximum Temperature (˚C) Ignition Temperature (˚C)
T1 450 > 450
T2 300 > 300
T3 200 > 200
T4 135 > 135
T5 100 > 100
T6 85 > 85
Reference Guide
4
12
Protection
Symbol
Zones
Description Drawing
0 1 2
d
e
i
ia
R L
CUib
ic
m
ma
mb
mc
n
o
p
q
Type of protection in which the parts which can ignite an explosive
atmosphere are placed in an enclosure which can withstand the
pressure developed during an internal explosion of an explosive
mixture and which prevents the transmission of the explosion to
the explosive atmospheres surrounding the enclosure.
Type of protection in which measures are applied so as to
prevent with a higher degree of safety the possibility of exces-
sive temperatures and of the occurrence of arcs or sparks in
the interior and on the external parts of electrical apparatus,
which does not produce them in normal service.
Type of protection when no spark or any thermal effect in the
circuit, produced in the test conditions prescribed in the
standard (which include normal operation and specic fault
conditions), is capable of causing ignition.
Type of protection in which the parts which can ignite an
explosive atmosphere are enclosed in a resin sufciently
resistant to the environmental influences in such a way that this
explosive atmosphere cannot be ignited by either sparking or
heating which may occur within the encapsulation.
Method of protection for electrical equipment designed so that
it will not ignite the surrounding explosive atmosphere in normal
operation and under certain fault conditions specied in the
standard. There are 4 categories of equipment: nA (non-
sparking), nC (enclosed break), nR (restricted breathing), nL
(limited energy).
Type of protection in which the electrical apparatus is
immersed in oil.
Type of protection in which the protective inert gas inside the
enclosure is maintained at a higher pressure than that of the
surrounding atmosphere.
Type of protection in which the enclosure is lled with a
material in a nely granulated state.
TYPES OF PROTECTION FOR ELECTRICAL APPARATUS FOR USE IN GAS ATMOSPHERES.
It is the comprehensive range of protective measures applied to an electrical apparatus to prevent possible ignition of the
surrounding atmosphere.
Reference Guide
4
13
Protection
symbol
Zones
Description Drawing
0 1 2
tD
mD
maD
mbD
iD
Electrical apparatus protected by enclosure and
surface temperature limitation for use in areas where
combustible dust may be present in quantities which
could lead to a re or explosion hazard. The ignition
protection is based on the limitation of the maximum
surface temperature of the enclosure and other surfaces
which may come into contact with dust and on the
restriction of dust ingress into the enclosure by the use
of “dust-tight” or “dust-protected” enclosures. This
standard is not applicable to electrical apparatus
intended for use in underground parts of mines as well
as those parts of surface installations of such mines
endangered by redamp and/or combustible dust;
nor does it take account of any risk due to an emission
of flammable or toxic gas from the dust.
Electrical apparatus protected by encapsulation type of
protection ‘mD’ and surface temperature limitation for
use in areas where combustible dust may be present in
quantities which could lead to a re or explosion
hazard. Type of protection in which the parts which can
ignite an explosive atmosphere are enclosed in a resin
sufficiently resistant to environmental influences in such
a way that a dust cloud or layer cannot be ignited
during installation or operation.
Intrinsically safe apparatus intended for use in potentially
explosive dust cloud or dust layer environments and for
associated apparatus that is intended for connection to
intrinsically safe circuits which enter such environments.
Applicable to electrical apparatus in which the electrical
circuits themselves are incapable of causing an explo-
sion in the surrounding combustible dust environment.
R L
CU
TYPES OF PROTECTION FOR ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE
DUST (EN 60241-0)
Applicable to electrical apparatus for use in areas where combustible dust may be present in quantities which could lead to a
fire or explosion hazard.
EN 61241-1 = tD ; EN 61241-18 = mD ; EN 61241-11 = iD
ASCO Valve, Inc. (USA) | Tel (1) 800.972.2726 | www.ascovalve.com | e-mail: info-valve@asco.com 06/15 — V7715
Global Contacts
Australia (61) 2-9-451-7077
Brazil (55) 11-4208-1700
Canada (1) 519-758-2700
China (86) 21-3395-0000
Czech Republic (420) 235-090-061
Dubai - UAE (971) 4 811 8200
France (33) 2-37-24-42-24
Germany (49) 7237-9960
India (91) 44-39197300
Italy (39) 02-356931
Japan (81) 798-65-6361
Mexico (52) 55-5809-5640
Netherlands (31) 33-277-7911
Singapore (65) 6556-1100
South Korea (82) 2-3483-1570
Spain (34) 942-87-6100
United Kingdom (44) 1695-713600

Weitere ähnliche Inhalte

Was ist angesagt?

Catalogo ttc.correntes e engrenagens
Catalogo ttc.correntes e engrenagensCatalogo ttc.correntes e engrenagens
Catalogo ttc.correntes e engrenagensNilson Moura
 
Angle bracket with and without gusset
Angle bracket with and without gussetAngle bracket with and without gusset
Angle bracket with and without gussetPiyaliDey14
 
Aula unid 3_4
Aula unid 3_4Aula unid 3_4
Aula unid 3_4riggingman
 
Catalogo industrial-gates (3)
Catalogo industrial-gates (3)Catalogo industrial-gates (3)
Catalogo industrial-gates (3)thi sac thi sac
 
CatĂĄlogo de Retentores SabĂł
CatĂĄlogo de Retentores SabĂłCatĂĄlogo de Retentores SabĂł
CatĂĄlogo de Retentores SabĂłFernando Santos
 
Lista de dureza dos parafusos e porcas
Lista de dureza dos parafusos e porcasLista de dureza dos parafusos e porcas
Lista de dureza dos parafusos e porcasrafaelnun
 
Catalogo correias-goodyear
Catalogo correias-goodyearCatalogo correias-goodyear
Catalogo correias-goodyearLuedes Viana
 
P & i diagram and tagging philosphy for
P & i diagram and tagging philosphy forP & i diagram and tagging philosphy for
P & i diagram and tagging philosphy forPrem Baboo
 
Copper Cable Lugs and Terminals Catalogue
Copper Cable Lugs and Terminals CatalogueCopper Cable Lugs and Terminals Catalogue
Copper Cable Lugs and Terminals CatalogueGrey Hawk Electricals
 
ASME B16.9 (2013) - Factory Made Wrought Buttwelding fittings..pdf
ASME B16.9 (2013) - Factory Made Wrought Buttwelding fittings..pdfASME B16.9 (2013) - Factory Made Wrought Buttwelding fittings..pdf
ASME B16.9 (2013) - Factory Made Wrought Buttwelding fittings..pdfbarrantes1974
 
60476640 n-0046-vaos-maximos-entre-suportes-de-tubulacao (2)
60476640 n-0046-vaos-maximos-entre-suportes-de-tubulacao (2)60476640 n-0046-vaos-maximos-entre-suportes-de-tubulacao (2)
60476640 n-0046-vaos-maximos-entre-suportes-de-tubulacao (2)Jupira Silva
 
Machine design lab manual
Machine design lab manualMachine design lab manual
Machine design lab manualbadri21
 
Flanges
FlangesFlanges
FlangesK0042
 
Cable lugs-lv-lugs-cembre
Cable lugs-lv-lugs-cembreCable lugs-lv-lugs-cembre
Cable lugs-lv-lugs-cembreAKBAR TRADING
 
Tabela de conversĂľes de durezas
Tabela de conversĂľes de durezasTabela de conversĂľes de durezas
Tabela de conversĂľes de durezasJosĂŠ Lima
 

Was ist angesagt? (20)

inspetor Dimensional de 008
inspetor Dimensional de  008 inspetor Dimensional de  008
inspetor Dimensional de 008
 
Catalogo ttc.correntes e engrenagens
Catalogo ttc.correntes e engrenagensCatalogo ttc.correntes e engrenagens
Catalogo ttc.correntes e engrenagens
 
Angle bracket with and without gusset
Angle bracket with and without gussetAngle bracket with and without gusset
Angle bracket with and without gusset
 
Balancing of reciprocating masses
Balancing of reciprocating masses Balancing of reciprocating masses
Balancing of reciprocating masses
 
Aula unid 3_4
Aula unid 3_4Aula unid 3_4
Aula unid 3_4
 
Catalogo industrial-gates (3)
Catalogo industrial-gates (3)Catalogo industrial-gates (3)
Catalogo industrial-gates (3)
 
CatĂĄlogo de Retentores SabĂł
CatĂĄlogo de Retentores SabĂłCatĂĄlogo de Retentores SabĂł
CatĂĄlogo de Retentores SabĂł
 
Tabela de roscas x furos
Tabela de roscas x furosTabela de roscas x furos
Tabela de roscas x furos
 
Lista de dureza dos parafusos e porcas
Lista de dureza dos parafusos e porcasLista de dureza dos parafusos e porcas
Lista de dureza dos parafusos e porcas
 
Eslingas de cable
Eslingas de cableEslingas de cable
Eslingas de cable
 
Catalogo correias-goodyear
Catalogo correias-goodyearCatalogo correias-goodyear
Catalogo correias-goodyear
 
En iso 13920
En iso 13920En iso 13920
En iso 13920
 
P & i diagram and tagging philosphy for
P & i diagram and tagging philosphy forP & i diagram and tagging philosphy for
P & i diagram and tagging philosphy for
 
Copper Cable Lugs and Terminals Catalogue
Copper Cable Lugs and Terminals CatalogueCopper Cable Lugs and Terminals Catalogue
Copper Cable Lugs and Terminals Catalogue
 
ASME B16.9 (2013) - Factory Made Wrought Buttwelding fittings..pdf
ASME B16.9 (2013) - Factory Made Wrought Buttwelding fittings..pdfASME B16.9 (2013) - Factory Made Wrought Buttwelding fittings..pdf
ASME B16.9 (2013) - Factory Made Wrought Buttwelding fittings..pdf
 
60476640 n-0046-vaos-maximos-entre-suportes-de-tubulacao (2)
60476640 n-0046-vaos-maximos-entre-suportes-de-tubulacao (2)60476640 n-0046-vaos-maximos-entre-suportes-de-tubulacao (2)
60476640 n-0046-vaos-maximos-entre-suportes-de-tubulacao (2)
 
Machine design lab manual
Machine design lab manualMachine design lab manual
Machine design lab manual
 
Flanges
FlangesFlanges
Flanges
 
Cable lugs-lv-lugs-cembre
Cable lugs-lv-lugs-cembreCable lugs-lv-lugs-cembre
Cable lugs-lv-lugs-cembre
 
Tabela de conversĂľes de durezas
Tabela de conversĂľes de durezasTabela de conversĂľes de durezas
Tabela de conversĂľes de durezas
 

Andere mochten auch

Hazardous Area Location Guide - IEC NEC CEC & ATEX By Emerson Industrial
Hazardous Area Location Guide - IEC NEC CEC & ATEX By Emerson IndustrialHazardous Area Location Guide - IEC NEC CEC & ATEX By Emerson Industrial
Hazardous Area Location Guide - IEC NEC CEC & ATEX By Emerson IndustrialThorne & Derrick International
 
ASCO - Solenoid Valves - Oil & Gas Industry Brochure
ASCO - Solenoid Valves - Oil & Gas Industry BrochureASCO - Solenoid Valves - Oil & Gas Industry Brochure
ASCO - Solenoid Valves - Oil & Gas Industry BrochureThorne & Derrick UK
 
ASCO Solenoid Valves - Process Industry Applications
ASCO Solenoid Valves - Process Industry ApplicationsASCO Solenoid Valves - Process Industry Applications
ASCO Solenoid Valves - Process Industry ApplicationsThorne & Derrick UK
 
Gas Detection - Know The Risks. Deepwater Explosion
Gas Detection - Know The Risks. Deepwater ExplosionGas Detection - Know The Risks. Deepwater Explosion
Gas Detection - Know The Risks. Deepwater ExplosionThorne & Derrick International
 
Hazardous Area Equipment Certification - ATEX (Zone 1 Zone 2), IEC Ex, NEMA (...
Hazardous Area Equipment Certification - ATEX (Zone 1 Zone 2), IEC Ex, NEMA (...Hazardous Area Equipment Certification - ATEX (Zone 1 Zone 2), IEC Ex, NEMA (...
Hazardous Area Equipment Certification - ATEX (Zone 1 Zone 2), IEC Ex, NEMA (...Thorne & Derrick International
 
Explosion Proof Solenoid Valves & Hazardous Areas
Explosion Proof Solenoid Valves & Hazardous AreasExplosion Proof Solenoid Valves & Hazardous Areas
Explosion Proof Solenoid Valves & Hazardous AreasThorne & Derrick UK
 
Crowcon Fixed Gas Detectors - Product Brochure
Crowcon Fixed Gas Detectors - Product BrochureCrowcon Fixed Gas Detectors - Product Brochure
Crowcon Fixed Gas Detectors - Product BrochureThorne & Derrick UK
 
Crowcon Portable Gas Detectors - Product Brochure
Crowcon Portable Gas Detectors - Product BrochureCrowcon Portable Gas Detectors - Product Brochure
Crowcon Portable Gas Detectors - Product BrochureThorne & Derrick UK
 
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...Thorne & Derrick International
 
2015-03 HxRefactored Building Healthcare Businesses
2015-03 HxRefactored Building Healthcare Businesses2015-03 HxRefactored Building Healthcare Businesses
2015-03 HxRefactored Building Healthcare Businessesimagine.GO
 
Asco Hazardous Area Solenoid Valves - Sil 3 Functional-Safety
Asco Hazardous Area Solenoid Valves - Sil 3 Functional-SafetyAsco Hazardous Area Solenoid Valves - Sil 3 Functional-Safety
Asco Hazardous Area Solenoid Valves - Sil 3 Functional-SafetyThorne & Derrick UK
 
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec SheetFiloform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec SheetThorne & Derrick International
 
Geo Therm LTD Thermal Imaging Surveys - Brochure
Geo Therm LTD Thermal Imaging Surveys - BrochureGeo Therm LTD Thermal Imaging Surveys - Brochure
Geo Therm LTD Thermal Imaging Surveys - BrochureThorne & Derrick International
 
VEGA Ultrasonic Level Measurement - VEGASON Ultrasonic Level Transmitters
VEGA Ultrasonic Level Measurement - VEGASON Ultrasonic Level TransmittersVEGA Ultrasonic Level Measurement - VEGASON Ultrasonic Level Transmitters
VEGA Ultrasonic Level Measurement - VEGASON Ultrasonic Level TransmittersThorne & Derrick UK
 
3M Scotchcast Flexible & Trailing Power Cable Splice Kits 82-F - Instruction
3M Scotchcast Flexible & Trailing Power Cable Splice Kits 82-F - Instruction3M Scotchcast Flexible & Trailing Power Cable Splice Kits 82-F - Instruction
3M Scotchcast Flexible & Trailing Power Cable Splice Kits 82-F - InstructionThorne & Derrick International
 
Offshore Hydrocarbon Releases (2001-2008) - A Report by the UK HSE
Offshore Hydrocarbon Releases (2001-2008) - A Report by the UK HSEOffshore Hydrocarbon Releases (2001-2008) - A Report by the UK HSE
Offshore Hydrocarbon Releases (2001-2008) - A Report by the UK HSEThorne & Derrick International
 

Andere mochten auch (18)

Hazardous Area Location Guide - IEC NEC CEC & ATEX By Emerson Industrial
Hazardous Area Location Guide - IEC NEC CEC & ATEX By Emerson IndustrialHazardous Area Location Guide - IEC NEC CEC & ATEX By Emerson Industrial
Hazardous Area Location Guide - IEC NEC CEC & ATEX By Emerson Industrial
 
ASCO - Solenoid Valves - Oil & Gas Industry Brochure
ASCO - Solenoid Valves - Oil & Gas Industry BrochureASCO - Solenoid Valves - Oil & Gas Industry Brochure
ASCO - Solenoid Valves - Oil & Gas Industry Brochure
 
ASCO Solenoid Valves - Process Industry Applications
ASCO Solenoid Valves - Process Industry ApplicationsASCO Solenoid Valves - Process Industry Applications
ASCO Solenoid Valves - Process Industry Applications
 
Gas Detection - Know The Risks. Deepwater Explosion
Gas Detection - Know The Risks. Deepwater ExplosionGas Detection - Know The Risks. Deepwater Explosion
Gas Detection - Know The Risks. Deepwater Explosion
 
Hazardous Area Equipment Certification - ATEX (Zone 1 Zone 2), IEC Ex, NEMA (...
Hazardous Area Equipment Certification - ATEX (Zone 1 Zone 2), IEC Ex, NEMA (...Hazardous Area Equipment Certification - ATEX (Zone 1 Zone 2), IEC Ex, NEMA (...
Hazardous Area Equipment Certification - ATEX (Zone 1 Zone 2), IEC Ex, NEMA (...
 
Explosion Proof Solenoid Valves & Hazardous Areas
Explosion Proof Solenoid Valves & Hazardous AreasExplosion Proof Solenoid Valves & Hazardous Areas
Explosion Proof Solenoid Valves & Hazardous Areas
 
Crowcon Fixed Gas Detectors - Product Brochure
Crowcon Fixed Gas Detectors - Product BrochureCrowcon Fixed Gas Detectors - Product Brochure
Crowcon Fixed Gas Detectors - Product Brochure
 
Crowcon Portable Gas Detectors - Product Brochure
Crowcon Portable Gas Detectors - Product BrochureCrowcon Portable Gas Detectors - Product Brochure
Crowcon Portable Gas Detectors - Product Brochure
 
Conductix Wampfler Product Overview Cables
Conductix Wampfler Product Overview CablesConductix Wampfler Product Overview Cables
Conductix Wampfler Product Overview Cables
 
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
 
2015-03 HxRefactored Building Healthcare Businesses
2015-03 HxRefactored Building Healthcare Businesses2015-03 HxRefactored Building Healthcare Businesses
2015-03 HxRefactored Building Healthcare Businesses
 
Asco Hazardous Area Solenoid Valves - Sil 3 Functional-Safety
Asco Hazardous Area Solenoid Valves - Sil 3 Functional-SafetyAsco Hazardous Area Solenoid Valves - Sil 3 Functional-Safety
Asco Hazardous Area Solenoid Valves - Sil 3 Functional-Safety
 
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec SheetFiloform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
 
Geo Therm LTD Thermal Imaging Surveys - Brochure
Geo Therm LTD Thermal Imaging Surveys - BrochureGeo Therm LTD Thermal Imaging Surveys - Brochure
Geo Therm LTD Thermal Imaging Surveys - Brochure
 
Crowcon Portable Gas Detectors Product Brochure
Crowcon Portable Gas Detectors Product BrochureCrowcon Portable Gas Detectors Product Brochure
Crowcon Portable Gas Detectors Product Brochure
 
VEGA Ultrasonic Level Measurement - VEGASON Ultrasonic Level Transmitters
VEGA Ultrasonic Level Measurement - VEGASON Ultrasonic Level TransmittersVEGA Ultrasonic Level Measurement - VEGASON Ultrasonic Level Transmitters
VEGA Ultrasonic Level Measurement - VEGASON Ultrasonic Level Transmitters
 
3M Scotchcast Flexible & Trailing Power Cable Splice Kits 82-F - Instruction
3M Scotchcast Flexible & Trailing Power Cable Splice Kits 82-F - Instruction3M Scotchcast Flexible & Trailing Power Cable Splice Kits 82-F - Instruction
3M Scotchcast Flexible & Trailing Power Cable Splice Kits 82-F - Instruction
 
Offshore Hydrocarbon Releases (2001-2008) - A Report by the UK HSE
Offshore Hydrocarbon Releases (2001-2008) - A Report by the UK HSEOffshore Hydrocarbon Releases (2001-2008) - A Report by the UK HSE
Offshore Hydrocarbon Releases (2001-2008) - A Report by the UK HSE
 

Ähnlich wie ASCO Solenoid Valves - Hazardous Area ATEX Certified Valves - New Catalogue

ASTAVA-BV-Holland-Catalog
ASTAVA-BV-Holland-CatalogASTAVA-BV-Holland-Catalog
ASTAVA-BV-Holland-Catalognishadvellur
 
Flame control products for industrial fluid operations
Flame control products for industrial fluid operationsFlame control products for industrial fluid operations
Flame control products for industrial fluid operationsCTi Controltech
 
Perfect Engineers, Mumbai, Camlock Coupler
Perfect Engineers, Mumbai, Camlock CouplerPerfect Engineers, Mumbai, Camlock Coupler
Perfect Engineers, Mumbai, Camlock CouplerIndiaMART InterMESH Limited
 
ASCO Compact Actuator Control System
ASCO Compact Actuator Control SystemASCO Compact Actuator Control System
ASCO Compact Actuator Control SystemThorne & Derrick UK
 
Orto Alresa series_Digtor_22_C_ENG.pdf
Orto Alresa series_Digtor_22_C_ENG.pdfOrto Alresa series_Digtor_22_C_ENG.pdf
Orto Alresa series_Digtor_22_C_ENG.pdfssuserfd0f7b
 
As schneider-customer-magazine-offshore-2017-en
As schneider-customer-magazine-offshore-2017-enAs schneider-customer-magazine-offshore-2017-en
As schneider-customer-magazine-offshore-2017-enZulfan Syahputra
 
Heat Shrink Cable Joints & Cable Terminations LV HV, 6.6kV 11kV 33kV - SPS Ca...
Heat Shrink Cable Joints & Cable Terminations LV HV, 6.6kV 11kV 33kV - SPS Ca...Heat Shrink Cable Joints & Cable Terminations LV HV, 6.6kV 11kV 33kV - SPS Ca...
Heat Shrink Cable Joints & Cable Terminations LV HV, 6.6kV 11kV 33kV - SPS Ca...Thorne & Derrick International
 
wkm-370d6-trunnion-mounted-ball-valves-br (1).pdf
wkm-370d6-trunnion-mounted-ball-valves-br (1).pdfwkm-370d6-trunnion-mounted-ball-valves-br (1).pdf
wkm-370d6-trunnion-mounted-ball-valves-br (1).pdfanuarsg
 
ASCO Valves - Valve Selection by Alphanumerical Or Numerical System
ASCO Valves - Valve Selection by Alphanumerical Or Numerical SystemASCO Valves - Valve Selection by Alphanumerical Or Numerical System
ASCO Valves - Valve Selection by Alphanumerical Or Numerical SystemThorne & Derrick International
 
Technical fligt specification LL pumps.pdf
Technical fligt specification LL pumps.pdfTechnical fligt specification LL pumps.pdf
Technical fligt specification LL pumps.pdfutovic73
 
Control Valves - Cashco Products
Control Valves - Cashco ProductsControl Valves - Cashco Products
Control Valves - Cashco ProductsBenjamin Kyalo
 
Cashco - VĂĄlvula de Controle
Cashco - VĂĄlvula de ControleCashco - VĂĄlvula de Controle
Cashco - VĂĄlvula de ControleRenan Sehn Santos
 

Ähnlich wie ASCO Solenoid Valves - Hazardous Area ATEX Certified Valves - New Catalogue (20)

Carten SPDSA Series
Carten SPDSA SeriesCarten SPDSA Series
Carten SPDSA Series
 
ASTAVA-BV-Holland-Catalog
ASTAVA-BV-Holland-CatalogASTAVA-BV-Holland-Catalog
ASTAVA-BV-Holland-Catalog
 
Flame control products for industrial fluid operations
Flame control products for industrial fluid operationsFlame control products for industrial fluid operations
Flame control products for industrial fluid operations
 
Perfect Engineers, Mumbai, Camlock Coupler
Perfect Engineers, Mumbai, Camlock CouplerPerfect Engineers, Mumbai, Camlock Coupler
Perfect Engineers, Mumbai, Camlock Coupler
 
ASCO Compact Actuator Control System
ASCO Compact Actuator Control SystemASCO Compact Actuator Control System
ASCO Compact Actuator Control System
 
Steam Tracing Temperature Regulator
Steam Tracing Temperature RegulatorSteam Tracing Temperature Regulator
Steam Tracing Temperature Regulator
 
Terofox dual check, butterfly (rev.00)
Terofox dual check, butterfly (rev.00) Terofox dual check, butterfly (rev.00)
Terofox dual check, butterfly (rev.00)
 
Orto Alresa series_Digtor_22_C_ENG.pdf
Orto Alresa series_Digtor_22_C_ENG.pdfOrto Alresa series_Digtor_22_C_ENG.pdf
Orto Alresa series_Digtor_22_C_ENG.pdf
 
Asco
AscoAsco
Asco
 
As schneider-customer-magazine-offshore-2017-en
As schneider-customer-magazine-offshore-2017-enAs schneider-customer-magazine-offshore-2017-en
As schneider-customer-magazine-offshore-2017-en
 
Heat Shrink Cable Joints & Cable Terminations LV HV, 6.6kV 11kV 33kV - SPS Ca...
Heat Shrink Cable Joints & Cable Terminations LV HV, 6.6kV 11kV 33kV - SPS Ca...Heat Shrink Cable Joints & Cable Terminations LV HV, 6.6kV 11kV 33kV - SPS Ca...
Heat Shrink Cable Joints & Cable Terminations LV HV, 6.6kV 11kV 33kV - SPS Ca...
 
wkm-370d6-trunnion-mounted-ball-valves-br (1).pdf
wkm-370d6-trunnion-mounted-ball-valves-br (1).pdfwkm-370d6-trunnion-mounted-ball-valves-br (1).pdf
wkm-370d6-trunnion-mounted-ball-valves-br (1).pdf
 
ASCO Valves - Valve Selection by Alphanumerical Or Numerical System
ASCO Valves - Valve Selection by Alphanumerical Or Numerical SystemASCO Valves - Valve Selection by Alphanumerical Or Numerical System
ASCO Valves - Valve Selection by Alphanumerical Or Numerical System
 
Sliding Gate Valve With Variable Orifice
Sliding Gate Valve With Variable OrificeSliding Gate Valve With Variable Orifice
Sliding Gate Valve With Variable Orifice
 
Thermoplastic Floating Ball Valves
Thermoplastic Floating Ball ValvesThermoplastic Floating Ball Valves
Thermoplastic Floating Ball Valves
 
Technical fligt specification LL pumps.pdf
Technical fligt specification LL pumps.pdfTechnical fligt specification LL pumps.pdf
Technical fligt specification LL pumps.pdf
 
Control Valves - Cashco Products
Control Valves - Cashco ProductsControl Valves - Cashco Products
Control Valves - Cashco Products
 
Cashco - VĂĄlvula de Controle
Cashco - VĂĄlvula de ControleCashco - VĂĄlvula de Controle
Cashco - VĂĄlvula de Controle
 
Catalogo dorot
Catalogo dorotCatalogo dorot
Catalogo dorot
 
Mark 76 On/Off Control Valve
Mark 76 On/Off Control ValveMark 76 On/Off Control Valve
Mark 76 On/Off Control Valve
 

Mehr von Thorne & Derrick International

Isolation procedures for safe working on electrical systems and equipment by ...
Isolation procedures for safe working on electrical systems and equipment by ...Isolation procedures for safe working on electrical systems and equipment by ...
Isolation procedures for safe working on electrical systems and equipment by ...Thorne & Derrick International
 
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical EqptTHORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical EqptThorne & Derrick International
 
The Children North East Annual Golf Day Wednesday 9th May 2018
The Children North East Annual Golf Day Wednesday 9th May 2018The Children North East Annual Golf Day Wednesday 9th May 2018
The Children North East Annual Golf Day Wednesday 9th May 2018Thorne & Derrick International
 
3M Electrical Products Stocked By Thorne & Derrick International
3M Electrical Products Stocked By Thorne & Derrick International3M Electrical Products Stocked By Thorne & Derrick International
3M Electrical Products Stocked By Thorne & Derrick InternationalThorne & Derrick International
 
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-AThorne & Derrick International
 
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...Thorne & Derrick International
 
Roxtec Cable Transit - B Frame Dimensional Drawing
Roxtec Cable Transit - B Frame Dimensional DrawingRoxtec Cable Transit - B Frame Dimensional Drawing
Roxtec Cable Transit - B Frame Dimensional DrawingThorne & Derrick International
 
Pepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
Pepperl & Fuchs SIL Training Certificate - T&D Adam RowePepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
Pepperl & Fuchs SIL Training Certificate - T&D Adam RoweThorne & Derrick International
 
T&D Experts In Equipment For Explosive Atmospheres
T&D Experts In Equipment For Explosive AtmospheresT&D Experts In Equipment For Explosive Atmospheres
T&D Experts In Equipment For Explosive AtmospheresThorne & Derrick International
 
Ultrasonic Flow Meters - Customer Specification Demand
Ultrasonic Flow Meters - Customer Specification DemandUltrasonic Flow Meters - Customer Specification Demand
Ultrasonic Flow Meters - Customer Specification DemandThorne & Derrick International
 
Emtelle Fibre Optic Cables - Product Catalogue 2016
Emtelle Fibre Optic Cables - Product Catalogue 2016Emtelle Fibre Optic Cables - Product Catalogue 2016
Emtelle Fibre Optic Cables - Product Catalogue 2016Thorne & Derrick International
 
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282DSIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282DThorne & Derrick International
 
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...Thorne & Derrick International
 
Temperature Calibrators - Sika Instruments Overview
Temperature Calibrators - Sika Instruments OverviewTemperature Calibrators - Sika Instruments Overview
Temperature Calibrators - Sika Instruments OverviewThorne & Derrick International
 

Mehr von Thorne & Derrick International (20)

Isolation procedures for safe working on electrical systems and equipment by ...
Isolation procedures for safe working on electrical systems and equipment by ...Isolation procedures for safe working on electrical systems and equipment by ...
Isolation procedures for safe working on electrical systems and equipment by ...
 
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical EqptTHORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
 
The Children North East Annual Golf Day Wednesday 9th May 2018
The Children North East Annual Golf Day Wednesday 9th May 2018The Children North East Annual Golf Day Wednesday 9th May 2018
The Children North East Annual Golf Day Wednesday 9th May 2018
 
3M Electrical Products Stocked By Thorne & Derrick International
3M Electrical Products Stocked By Thorne & Derrick International3M Electrical Products Stocked By Thorne & Derrick International
3M Electrical Products Stocked By Thorne & Derrick International
 
CATU Electrical Safety Catalogue
CATU Electrical Safety CatalogueCATU Electrical Safety Catalogue
CATU Electrical Safety Catalogue
 
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
 
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
 
Roxtec Cable Transit - B Frame Dimensional Drawing
Roxtec Cable Transit - B Frame Dimensional DrawingRoxtec Cable Transit - B Frame Dimensional Drawing
Roxtec Cable Transit - B Frame Dimensional Drawing
 
Pepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
Pepperl & Fuchs SIL Training Certificate - T&D Adam RowePepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
Pepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
 
T&D Experts In Equipment For Explosive Atmospheres
T&D Experts In Equipment For Explosive AtmospheresT&D Experts In Equipment For Explosive Atmospheres
T&D Experts In Equipment For Explosive Atmospheres
 
Ultrasonic Flow Meters - Customer Specification Demand
Ultrasonic Flow Meters - Customer Specification DemandUltrasonic Flow Meters - Customer Specification Demand
Ultrasonic Flow Meters - Customer Specification Demand
 
Emtelle Fibre Optic Cables - Product Catalogue 2016
Emtelle Fibre Optic Cables - Product Catalogue 2016Emtelle Fibre Optic Cables - Product Catalogue 2016
Emtelle Fibre Optic Cables - Product Catalogue 2016
 
Thorne & Derrick Process Heating Brochure 2016
Thorne & Derrick Process Heating Brochure 2016Thorne & Derrick Process Heating Brochure 2016
Thorne & Derrick Process Heating Brochure 2016
 
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282DSIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
 
Ripley Utility Tool Cable Preparation Tools
Ripley Utility Tool Cable Preparation ToolsRipley Utility Tool Cable Preparation Tools
Ripley Utility Tool Cable Preparation Tools
 
RIDGID micro CD100 Combustible Gas Detector
RIDGID micro CD100 Combustible Gas DetectorRIDGID micro CD100 Combustible Gas Detector
RIDGID micro CD100 Combustible Gas Detector
 
Itron Fact Sheet
Itron Fact SheetItron Fact Sheet
Itron Fact Sheet
 
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
 
Eltherm Self-Regulating Trace Heating Cables
Eltherm Self-Regulating Trace Heating CablesEltherm Self-Regulating Trace Heating Cables
Eltherm Self-Regulating Trace Heating Cables
 
Temperature Calibrators - Sika Instruments Overview
Temperature Calibrators - Sika Instruments OverviewTemperature Calibrators - Sika Instruments Overview
Temperature Calibrators - Sika Instruments Overview
 

KĂźrzlich hochgeladen

"I see eyes in my soup": How Delivery Hero implemented the safety system for ...
"I see eyes in my soup": How Delivery Hero implemented the safety system for ..."I see eyes in my soup": How Delivery Hero implemented the safety system for ...
"I see eyes in my soup": How Delivery Hero implemented the safety system for ...Zilliz
 
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot TakeoffStrategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoffsammart93
 
AWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of TerraformAWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of TerraformAndrey Devyatkin
 
Polkadot JAM Slides - Token2049 - By Dr. Gavin Wood
Polkadot JAM Slides - Token2049 - By Dr. Gavin WoodPolkadot JAM Slides - Token2049 - By Dr. Gavin Wood
Polkadot JAM Slides - Token2049 - By Dr. Gavin WoodJuan lago vĂĄzquez
 
Exploring Multimodal Embeddings with Milvus
Exploring Multimodal Embeddings with MilvusExploring Multimodal Embeddings with Milvus
Exploring Multimodal Embeddings with MilvusZilliz
 
ICT role in 21st century education and its challenges
ICT role in 21st century education and its challengesICT role in 21st century education and its challenges
ICT role in 21st century education and its challengesrafiqahmad00786416
 
Apidays New York 2024 - Accelerating FinTech Innovation by Vasa Krishnan, Fin...
Apidays New York 2024 - Accelerating FinTech Innovation by Vasa Krishnan, Fin...Apidays New York 2024 - Accelerating FinTech Innovation by Vasa Krishnan, Fin...
Apidays New York 2024 - Accelerating FinTech Innovation by Vasa Krishnan, Fin...apidays
 
How to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerHow to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerThousandEyes
 
Six Myths about Ontologies: The Basics of Formal Ontology
Six Myths about Ontologies: The Basics of Formal OntologySix Myths about Ontologies: The Basics of Formal Ontology
Six Myths about Ontologies: The Basics of Formal Ontologyjohnbeverley2021
 
Apidays New York 2024 - The value of a flexible API Management solution for O...
Apidays New York 2024 - The value of a flexible API Management solution for O...Apidays New York 2024 - The value of a flexible API Management solution for O...
Apidays New York 2024 - The value of a flexible API Management solution for O...apidays
 
presentation ICT roal in 21st century education
presentation ICT roal in 21st century educationpresentation ICT roal in 21st century education
presentation ICT roal in 21st century educationjfdjdjcjdnsjd
 
AI in Action: Real World Use Cases by Anitaraj
AI in Action: Real World Use Cases by AnitarajAI in Action: Real World Use Cases by Anitaraj
AI in Action: Real World Use Cases by AnitarajAnitaRaj43
 
Introduction to use of FHIR Documents in ABDM
Introduction to use of FHIR Documents in ABDMIntroduction to use of FHIR Documents in ABDM
Introduction to use of FHIR Documents in ABDMKumar Satyam
 
AI+A11Y 11MAY2024 HYDERBAD GAAD 2024 - HelloA11Y (11 May 2024)
AI+A11Y 11MAY2024 HYDERBAD GAAD 2024 - HelloA11Y (11 May 2024)AI+A11Y 11MAY2024 HYDERBAD GAAD 2024 - HelloA11Y (11 May 2024)
AI+A11Y 11MAY2024 HYDERBAD GAAD 2024 - HelloA11Y (11 May 2024)Samir Dash
 
Vector Search -An Introduction in Oracle Database 23ai.pptx
Vector Search -An Introduction in Oracle Database 23ai.pptxVector Search -An Introduction in Oracle Database 23ai.pptx
Vector Search -An Introduction in Oracle Database 23ai.pptxRemote DBA Services
 
Artificial Intelligence Chap.5 : Uncertainty
Artificial Intelligence Chap.5 : UncertaintyArtificial Intelligence Chap.5 : Uncertainty
Artificial Intelligence Chap.5 : UncertaintyKhushali Kathiriya
 
Understanding the FAA Part 107 License ..
Understanding the FAA Part 107 License ..Understanding the FAA Part 107 License ..
Understanding the FAA Part 107 License ..Christopher Logan Kennedy
 
TrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
TrustArc Webinar - Unlock the Power of AI-Driven Data DiscoveryTrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
TrustArc Webinar - Unlock the Power of AI-Driven Data DiscoveryTrustArc
 
Mcleodganj Call Girls 🥰 8617370543 Service Offer VIP Hot Model
Mcleodganj Call Girls 🥰 8617370543 Service Offer VIP Hot ModelMcleodganj Call Girls 🥰 8617370543 Service Offer VIP Hot Model
Mcleodganj Call Girls 🥰 8617370543 Service Offer VIP Hot ModelDeepika Singh
 
Apidays New York 2024 - Passkeys: Developing APIs to enable passwordless auth...
Apidays New York 2024 - Passkeys: Developing APIs to enable passwordless auth...Apidays New York 2024 - Passkeys: Developing APIs to enable passwordless auth...
Apidays New York 2024 - Passkeys: Developing APIs to enable passwordless auth...apidays
 

KĂźrzlich hochgeladen (20)

"I see eyes in my soup": How Delivery Hero implemented the safety system for ...
"I see eyes in my soup": How Delivery Hero implemented the safety system for ..."I see eyes in my soup": How Delivery Hero implemented the safety system for ...
"I see eyes in my soup": How Delivery Hero implemented the safety system for ...
 
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot TakeoffStrategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
 
AWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of TerraformAWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of Terraform
 
Polkadot JAM Slides - Token2049 - By Dr. Gavin Wood
Polkadot JAM Slides - Token2049 - By Dr. Gavin WoodPolkadot JAM Slides - Token2049 - By Dr. Gavin Wood
Polkadot JAM Slides - Token2049 - By Dr. Gavin Wood
 
Exploring Multimodal Embeddings with Milvus
Exploring Multimodal Embeddings with MilvusExploring Multimodal Embeddings with Milvus
Exploring Multimodal Embeddings with Milvus
 
ICT role in 21st century education and its challenges
ICT role in 21st century education and its challengesICT role in 21st century education and its challenges
ICT role in 21st century education and its challenges
 
Apidays New York 2024 - Accelerating FinTech Innovation by Vasa Krishnan, Fin...
Apidays New York 2024 - Accelerating FinTech Innovation by Vasa Krishnan, Fin...Apidays New York 2024 - Accelerating FinTech Innovation by Vasa Krishnan, Fin...
Apidays New York 2024 - Accelerating FinTech Innovation by Vasa Krishnan, Fin...
 
How to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerHow to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected Worker
 
Six Myths about Ontologies: The Basics of Formal Ontology
Six Myths about Ontologies: The Basics of Formal OntologySix Myths about Ontologies: The Basics of Formal Ontology
Six Myths about Ontologies: The Basics of Formal Ontology
 
Apidays New York 2024 - The value of a flexible API Management solution for O...
Apidays New York 2024 - The value of a flexible API Management solution for O...Apidays New York 2024 - The value of a flexible API Management solution for O...
Apidays New York 2024 - The value of a flexible API Management solution for O...
 
presentation ICT roal in 21st century education
presentation ICT roal in 21st century educationpresentation ICT roal in 21st century education
presentation ICT roal in 21st century education
 
AI in Action: Real World Use Cases by Anitaraj
AI in Action: Real World Use Cases by AnitarajAI in Action: Real World Use Cases by Anitaraj
AI in Action: Real World Use Cases by Anitaraj
 
Introduction to use of FHIR Documents in ABDM
Introduction to use of FHIR Documents in ABDMIntroduction to use of FHIR Documents in ABDM
Introduction to use of FHIR Documents in ABDM
 
AI+A11Y 11MAY2024 HYDERBAD GAAD 2024 - HelloA11Y (11 May 2024)
AI+A11Y 11MAY2024 HYDERBAD GAAD 2024 - HelloA11Y (11 May 2024)AI+A11Y 11MAY2024 HYDERBAD GAAD 2024 - HelloA11Y (11 May 2024)
AI+A11Y 11MAY2024 HYDERBAD GAAD 2024 - HelloA11Y (11 May 2024)
 
Vector Search -An Introduction in Oracle Database 23ai.pptx
Vector Search -An Introduction in Oracle Database 23ai.pptxVector Search -An Introduction in Oracle Database 23ai.pptx
Vector Search -An Introduction in Oracle Database 23ai.pptx
 
Artificial Intelligence Chap.5 : Uncertainty
Artificial Intelligence Chap.5 : UncertaintyArtificial Intelligence Chap.5 : Uncertainty
Artificial Intelligence Chap.5 : Uncertainty
 
Understanding the FAA Part 107 License ..
Understanding the FAA Part 107 License ..Understanding the FAA Part 107 License ..
Understanding the FAA Part 107 License ..
 
TrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
TrustArc Webinar - Unlock the Power of AI-Driven Data DiscoveryTrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
TrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
 
Mcleodganj Call Girls 🥰 8617370543 Service Offer VIP Hot Model
Mcleodganj Call Girls 🥰 8617370543 Service Offer VIP Hot ModelMcleodganj Call Girls 🥰 8617370543 Service Offer VIP Hot Model
Mcleodganj Call Girls 🥰 8617370543 Service Offer VIP Hot Model
 
Apidays New York 2024 - Passkeys: Developing APIs to enable passwordless auth...
Apidays New York 2024 - Passkeys: Developing APIs to enable passwordless auth...Apidays New York 2024 - Passkeys: Developing APIs to enable passwordless auth...
Apidays New York 2024 - Passkeys: Developing APIs to enable passwordless auth...
 

ASCO Solenoid Valves - Hazardous Area ATEX Certified Valves - New Catalogue

  • 1. Hazardous Location Solutions | for the Process Control Industry UL • CSA • FM • ATEX • IECEx • NEPSI • INMETRO • TR CU 4 w w w. a s c o v a l v e . c o m
  • 2. Global Approvals Fluid automation equipment must operate flawlessly in haz- ardous or explosive environments. Solenoid-operated valves are essential components in these challenging applications. They must comply with the strictest safety regulations while staying up and running, cycle after cycle, year after year. ASCO offers the world’s most comprehensive family of prod- ucts that hold approvals from the leading global agencies — UL, CSA, FM, ATEX, and IECEx. In addition, our valves are inspected and certified to NEPSI in China, INMETRO in Brazil, and TR CU in Russia. That means users can specify highly reliable ASCO valves in their designs and be assured they are approved for use in dangerous conditions — anywhere in the world. ASCO‘s global solutions for hazardous locations include valves available in the following models: • Standard 3-way and 4-way solenoid valves • Direct-acting and pilot-operated solenoid valves • Manual reset and NAMUR valves • Rugged 316L Stainless Steel valves for harsh environments • Low Power Intrinsically Safe and Non-Incendive Field Wiring solenoid valves • Low temperature constructions down to -58˚F (-50˚C) ASCO offers hundreds of valve constructions with various global approvals that can be exported worldwide. Our products are famous for their robust operator heads and extended service lives. These products are ideal for the mission-critical demands of power generation, chemical processing, oil, gas, and refining applications, plus general machinery, wellhead control, mining equipment and measuring and controlling devices. With more than 100 specialists and over 140 distributors in the U.S. alone, ASCO has the technical expertise that can rapidly solve application problems and help interpret confusing product codes and classifications. Our one-stop shopping offers time- saving convenience and rapid fulfillment. There’s only one source to specify; one contact number to call; one solution to keep in inventory. Only ASCO solenoid valves deliver the advanced designs, top-grade materials, meticulous manufacturing, and unequaled quality assurance that maximize durability and achieve unsur- passed performance in hazardous and explosive environments. If you cannot find the product you need or if you need more detailed specifications, visit www.ascovalve.com or call 800-972-2726. CAUTION: Users should consult www.ascovalve.com or Catalog 35 to see complete specifications for the products selected from this catalog. WARNING: Improper selection or use of products and related items in this catalog can cause death, serious injury, or property damage. ^ # %
  • 3. 1 Valve Series Type Pipe Size (in) Max. Cv (Kv) UL or FM √ CSA ATEX/IECEx TR CU INMETRO NEPSI Page EV 8314 3-Way 1/8-1/4 0.2 (.17) • • • ¨ - - - 2 & 4 EV 8316 3-Way 1/4-3/4 12.5 (11) • • • ¨ - - - 2 EV 8317 3-Way 1/4 0.73 (0.63) • • • ¨ - - - 2 & 4 EV 8320 3-Way 1/4 .35 (.30) • • • ¨ - - - 3 EV 8327 3-Way 1/4 .56 (.48) • • • ¨ - - - 4 EV 8344 4-Way 1/4-1/2 2.2 (1.89) • • • ¨ - - - 2 EV 8551 3-Way 4-Way 1/4 .86 (.75) • • • ¨ - - - 3 & 5 JPIS 8314 3-Way 1/4 .06 (.05) • • • ÂĄ - - • 2 JPIS 8316 3-Way 1/4-3/4 5.5 (4.7) • • • ÂĄ - - • 2 JPIS 8317 3-Way 1/4 .73 (.63) • • • ÂĄ - - • 2 JPIS 8344 4-Way 1/4-3/4 5.6 (4.8) • • • ÂĄ - - • 2 JPIS 8551 3-Way 4-Way 1/4 .86 (.75) • • • ÂĄ - - • 3 Harsh Environment 8320 3-Way 1/4 .16 (.14) • • • - - - 6 NF/WSNF 8316* 3-Way 1/4-1/2 3.9 (3.4) - - • ÂŹ • • • 6 NF/WSNF 8320* 3-Way 1/4 .24 (.21) - - • ÂŹ • • • 6 NF/WSNF 8327* 3-Way 1/4 .52 (.45) - - • ÂŹ • • • 6 & 7 NF/WSNF 8551* 3-Way 4-Way 1/4 .87 (.75) - - • ÂŹ • • • 6 & 7 ^ # % ¨ II 2G Ex d mb IIC T* Gb II 2D Ex mb IIIC T** Db IP67 Ex d mb IIC T* Gb Ex mb IIIC T** Db ÂĄ II 1 G Ex ia IIC T6 Ga under FM10ATEX0015X IECEx approved for: Ex ia IIC T6 Ga under IECExFMG10.0008X ÂŹ II 2G Ex d IIC Ga T6, II2D Ex + IIIC Db √ FM available for JPIS only *Designated products not included in the SameDay or 5Day program have lead times of three weeks or less. under SIRA 14 ATEX 1192X under IECEx SIR 14.0064X Explosion-proof EncapsulatedCoil IntrinsicSafety Explosion-proof Enclosure The majority of the items listed below are part of the ASCO Express Shipping program which includes ASCO SameDay and 5Day products: Items qualifying for SameDay shipping are guaranteed to ship same business day if the order is received before 3 P.M. EST with a maximum quantity of 25 pieces. Items qualifying for 5Day shipping are guaranteed to ship within 5 business days with a maximum quantity of 25 pieces. Hazardous Locations Product Offering
  • 4. Hazardous Location Solutions 4 2 Pipe Size (in) Orifice Size in (mm) Cv Flow Factor (Kv=m3 /h) Operating Pressure Differential psi (bar) Max. Fluid and Ambient Temp. °F (˚C) Brass Body Stainless Steel BodyAir-Inert Gas Pressure to Cylinder Cylinder to Exhaust Min. Max. Catalog Number Catalog Number Low Power (1.4 Watt) 3/2 VALVES, UNIVERSAL OPERATION (Normally Closed or Normally Open) with NBR Disc – SIL 3 Capable, Certified by Exida ∆ ≥ 1/4 1/16 (2) .08 (.07) .08 (.07) 0 150 (10) 140 (60) EV8314G300 EV8314G301 ≈ 3/2 VALVES, NORMALLY CLOSED (Closed when de-energized) with NBR Disc – SIL 3 Capable, Certified by Exida ∆ 1/4 5/16 (8) 1.5 (1.29) 1.5 (1.29) ƒ 150 (10) 140 (60) EV8316G301 ÂŹ EV8316G381 ≈ 3/8 5/16 (8) 1.8 (1.37) 1.8 (1.37) ƒ 150 (10) 140 (60) EV8316G302 ÂŹ EV8316G382 ≈ 3/8 5/8 (16) 4 (3.43) 4 (3.43) ƒ 150 (10) 140 (60) EV8316G303 ÂŹ - 1/2 5/8 (16) 4 (3.43) 4 (3.43) ƒ 150 (10) 140 (60) EV8316G304 ÂŹ EV8316G384 ≈ 3/2 VALVES, UNIVERSAL (Normally Closed or Normally Open) "Quick Exhaust" with CR Diaphragm and NBR Disc 1/4 ÂĄ .08 (.07) .73 (.63) 5 (0.3) 150 (10) 140 (60) - EV8317G308 ¨≈ 4/2 VALVES, Brass Body with NBR Disc 1/4 1/4 (6) .80 (0.69) 1 (0.86) 10 (0.7) 150 (10) 140 (60) EV8344G370 ¨ - 3/8 3/8 (10) 1.4 (1.20) 2.2 (1.89) 10 (0.7) 150 (10) 140 (60) EV8344G372 ¨ - 1/2 3/8 (10) 1.4 (1.20) 2.2 (1.89) 10 (0.7) 150 (10) 140 (60) EV8344G374 ¨ - Intrinsically Safe 3/2 VALVES, UNIVERSAL OPERATION (NORMALLY CLOSED or NORMALLY OPEN) with NBR Disc – SIL 3 Capable, Certified by Exida ∆ ≥ 1/4 1/20 (1.3) .06 (.05) .06 (.05) 0 130/105 (9/7) ≈ 149 (65) JPIS8314B300 - 3/2 VALVES, NORMALLY CLOSED (Closed when de-energized) with NBR Disc or FKM (Suffix V), as Listed – SIL 3 Capable, Certified by Exida ∆ 1/4 5/16 (8) 1.5 (1.3) 1.5 (1.3) ƒ 130 (9) 149 (65) JPIS8316B301 ÂŹ - 3/8 5/16 (8) 1.8 (1.6) 1.8 (1.6) ƒ 130 (9) 149 (65) JPIS8316B302 ÂŹ - 3/8 5/8 (16) 4 (3.5) 4 (3.5) ƒ 130 (9) 149 (65) JPIS8316B303 ÂŹ - 1/2 5/8 (16) 4 (3.5) 4 (3.5) ƒ 130 (9) 149 (65) JPIS8316B304 ÂŹ - 3/4 11/16 (17) 5.5 (4.7) 5.5 (4.7) 10 (0.7) 130 (9) 149 (65) JPIS8316B374 ÂŹ - 3/2 VALVES, UNIVERSAL (NORMALLY CLOSED or NORMALLY OPEN) "Quick Exhaust" with NBR Diaphragm and NBR Disc 1/4 ÂĄ .06 (.07) .73 (.63) 5 (0.3) 130 (9) 149 (65) JPIS8317B307 ¨ - 4/2 VALVES, Brass Body with NBR Disc 1/4 1/4 (6) .80 (.69) 1 (.86) 10 (0.7) 130 (9) 149 (65) JPIS8344B370 ¨ - 3/8 3/8 (10) 1.5 (1.3) 2.2 (1.9) 10 (0.7) 130 (9) 149 (65) JPIS8344B372 ¨ - 1/2 3/8 (10) 1.5 (1.3) 2.2 (1.9) 10 (0.7) 130 (9) 149 (65) JPIS8344B374 ¨ - 3/4 3/4 (19) 5.2 (4.5) 5.6 (4.8) 10 (0.7) 130 (9) 149 (65) JPIS8344B376 ¨ - ¨ There are two exhaust flows in the exhaust mode (pilot and main). The pilot exhaust must be connected to the main exhaust when the air or inert gas cannot be exhausted to atmosphere. ÂĄ For "Quick Exhaust" valves, pressure port is 1/16", exhaust port is 1/4". ÂŹ IMPORTANT: A Minimum Operating Pressure Differential must be maintained between the pressure and exhaust ports. Supply and exhaust piping must be full area, unrestricted. ASCO flow controls and other similar components must be installed in the cylinder lines only. ƒ Zero minimum when valve selection gasket is in external position and proper auxiliary air pressure is applied. Minimum 15 psi (1 bar) Operating Pressure Differential when selection gasket is in the internal position. ≈ Can be used for drynatural gas service with EV prefix. ∆ Safety manual and FMEDA (Failure Modes Effects and Diagnostic Analysis) report available. ≥ SIL 3 Capable, Certified by Exida only valid when used as Normally Closed. Low Power & Intrinsically Safe Low Power • Molded one-piece solenoid with highly efficient solenoid cartridge and special low wattage coil • Designed for use in automation of plant control systems to provide PLC compatibility and reduced battery drain Intrinsically Safe • Designed solely for installation in intrinsically safe or Non-Incendive Field Wiring (NIFW) areas, with properly approved and sized limiting barriers • Compatible with supervisory current applications ^ # %
  • 5. Hazardous Location Solutions 4 3 Body Material Pipe Size (in) Orifice Size in (mm) Cv Flow Factor (Kv=m3 /h) Single Solenoid – SIL 3 Capable, Certified by Exida ∆ Operating Pressure Differential psi (bar) Max. Fluid Temp. ˚F (˚C) Catalog Number Air-Inert Gas Min. Max. Low power - Spool Valves (1.4 Watt) 3/2, 5/2 VALVES, with NBR and PUR Seals, NAMUR Mount Aluminum 3/2, 5/2 1/4 1/4 (6) .86 (.7) 30 (2) 150 (10) 140 (60) EV8551G301 ¨ 316L Stainless Steel 3/2, 5/2 1/4 1/4 (6) .86 (.7) 30 (2) 150 (10) 140 (60) EV8551G309 ¬≈ Intrinsically Safe - Spool Valves 3/2, 5/2 VALVES, with NBR and PUR Seals, NAMUR Mount Aluminum 3/2, 5/2 1/4 1/4 (6) .86 (.74) 35 (2.4) 130 (9) 149 (65) JPIS8551B301 ¨ 316L Stainless Steel 3/2, 5/2 1/4 1/4 (6) .86 (.74) 35 (2.4) 130 (9) 149 (65) JPIS8551B309 ¨ 1/8" NPT exhaust for 1/4" aluminum and brass. ÂŹ Stainless steel construction supplied standard with EV solenoid. ≈ Can be used for drynatural gas service with EV prefix. ∆ Safety manual and FMEDA (Failure Modes Effects and Diagnostic Analysis) report available. Low Power & Intrinsically Safe Pipe Size (in) Orifice Size (in) Cv Flow Factor (Kv=m3 /h) Operating Pressure Differential psi (bar) Max. Fluid Temp. ˚F (˚C) Brass Body Stainless Steel Body Watt Rating/ Class of Coil InsulationMax. AC Max. DC Catalog Number Catalog Number Air-Inert Gas Water ƒ Lt. Oil @ 300 SSU Air-Inert Gas Water ƒ Lt. Oil @ 300 SSU AC DC AC DC 3-Way EV 8320 Series UNIVERSAL OPERATION (Pressure at any port) 1/4 1/16 (1.6) 0.09 (0.08) 125 (9) 130 (9) 130 (9) 75 (5) 75 (5) 75 (5) 200(93) 150 (66) EV8320G172 - 10.1/F 11.6/F 1/4 3/32 (2) 0.12 (0.10) 100 (7) 100 (7) 100 (7) 60 (4) 60 (4) 60 (4) 200(93) 150 (66) EV8320G174 EV8320G200 ¬√ 17.1/F 11.6/F 1/4 1/8 (3.2) 0.25 (0.21) 50 (3) 50 (3) 50 (3) 25 (2) 25 (2) 25 (2) 200(93) 150 (66) EV8320G176 - 17.1/F 11.6/F 1/4 11/64 (4.4) 0.35 (0.30) 20 (1) 20 (1) 20 (1) 12 (1) 12 (1) 12 (1) 200(93) 150 (66) EV8320G178 - 10.1/F 11.6/F NORMALLY CLOSED (Closed when de-energized) – PFDAVG = 6.81 x 10-4 1/4 1/16 (1.6) 0.09 (0.08) 210 (14) 225 (15) 225 (15) 160 (11) 160 (11) 160 (11) 200(93) 150 (66) EV8320G182 - 17.1/F 11.6/F 1/4 3/32 (2) 0.12 (0.10) 150 (10) 150 (10) 150 (10) 115 (8) 115 (8) 115 (8) 200(93) 150 (66) EV8320G184 EV8320G202 ¬√ 10.1/F 11.6/F 1/4 1/8 (3.2) 0.25 (0.21) 85 (6) 85 (6) 85 (6) 60 (4) 60 (4) 60 (4) 200(93) 150 (66) - EV8320G203 ¬√ 10.1/F 11.6/F NORMALLY OPEN (Open when de-energized) 1/4 1/16 (1.6) 0.09 (0.08) 235 (16) 250 (17) 250 (17) 160 (11) 160 (11) 160 (11) 200(93) 150 (66) EV8320G192 - 17.1/F 11.6/F 1/4 3/32 (2) 0.12 (0.10) 150 (10) 140 (10) 140 (10) 100 (7) 100 (7) 100 (7) 200(93) 150 (66) EV8320G194 - 10.1/F 11.6/F 1/4 1/8 (3.2) 0.25 (0.21) 70 (5) 70 (5) 70 (5) 55 (4) 55 (4) 55 (4) 200(93) 150 (66) EV8320G196 - 10.1/F 11.6/F ÂŹ Can be used for drynatural gas service with the EV prefix. √ Constructions standard rated -40˚F (-40˚C) ambient temperature. EVX prefix and TPL # not required. ƒ Water rating, CSA certified up to 232 psi (16 bar). 3-Way | General Service 8320 Series • All NPT connections are in the valve body to allow in-line piping • No Minimum Operating Pressure Differential required ^ # % ^ # %
  • 6. Hazardous Location Solutions 4 4 Pipe Size (in) Orifice Size in (mm) Cv Flow Factor (Kv=m3 /h) Operating Pressure Differential psi (bar) Max. Fluid Temp.˚F (˚C) Brass Body Stainless Steel Body Watt Rating/ Class of Coil Insulation ÂŹMax. AC Max. DC Catalog Number Catalog NumberPress. Exh. Press. Exh. Min. ¨ Air-Inert Gas Water Lt. Oil ¨ @45 SSU Air-Inert Gas Water Lt. Oil ¨ @45 SSU AC DC AC DC 3-Way EV 8317 Series NORMALLY CLOSED (Closed when de-energized) 1/4 3/32 (2) 1/4 (6) .20 (.17) .73( .63) 5 (.3) ≠ 150 (10) 150 (10) 95 (7) 75 (5) 55 (4) 30 (2) 180 (82) 104 (40) EV8317G035 EV8317G036 10.1/F 11.6/F ¨ Rating for 8321 valves established with 300 SSU light oil. ≠ Minimum Operating Pressure Differential on light oil is 10 psi (0.7 bar). Pipe Size (in) Orifice Size in (mm) Cv Flow Factor (Kv=m3 /h) 2-1 Cv Flow Factor (Kv=m3 /h) 1-3 Operating Pressure Differential psi (bar) Max. Fluid Temp.˚F (˚C) ¨ Brass Body Stainless Steel Body Watt Rating/ Class of Coil InsulationMax. AC Max. DC Catalog Number Catalog Number Air-Inert Gas Water ÂĄ Light Oil @ 45 SSU Air-Inert Gas Water ÂĄ Light Oil @ 45 SSU AC DC AC DC 3-Way EV 8314 Series UNIVERSAL OPERATION (Pressure at any port) 1/8 3/64 (1.2) 0.05 (0.04) 0.06 (0.05) 200 (14) 200 (14) 200 (14) 200 (14) 200 (14) 200 (14) 200 (93) 200 (93) EV8314H041 - 10.1/F 11.6/F 1/4 3/64 (1.2) 0.05 (0.04) 0.06 (0.05) 200 (14) 200 (14) 200 (14) 200 (14) 200 (14) 200 (14) 200 (93) 200 (93) EV8314H006 - 10.1/F 11.6/F NORMALLY CLOSED (Closed when de-energized) – PFDAVG = 4.77 x 10-4 1/4 3/32 (2.4) 0.15 (0.13) 0.20 (0.17) 205 (14) 205 (14) 190 (13) 150 (10) 120 (8) 90 (6) 200 (93) 200 (93) EV8314H035 EV8314H121 10.1/F 11.6/F ¨ Maximum fluid temperature for light oil @ 45 SSU is 180˚F (82˚C). ÂĄ Water rating, CSA certified up to 232 psi (16 bar). Pipe Size (in) Orifice Size in (mm) Cv Flow Factor (Kv=m3 /h) Maximum Operating Pressure Differential psi (bar) Max. Fluid Temp.˚F (˚C) Brass Body 316 Stainless Steel Body Const. Ref. Watt Rating/ Class of Coil Insulation Ports 1-2 Ports 2-3 Air-Inert Gas Water Light Oil @ 300 SSU Catalog Number Catalog Number AC DC 3-Way EV 8327 Series UNIVERSAL OPERATION (Pressure at any port) 1/4 1/4 (6) .49 (.42) .56 (.48) 150 (10) 150 (10) 150 (10) 176 (80) EV8327G041 – 1 12.0/F 11.6/F 1/4 1/4 (6) .49 (.42) .56 (.48) 150 (10) 150 (10) 150 (10) 248 (120) – EV8327G042 1 12.0/F 11.6/F 3-Way | General Service 8317 Series • Designed for quick exhaust to 0 psi through the exhaust orifice • Resilient seated poppets for tight shutoff 8314 Series • No minimum operating pressure required • Simplest valve for basic 3-way piloting operation, only one spring and two moving parts 8327 Series • Designed for high flow piloting with no minimum operating pressure required • Balanced poppet construction for high flow at minimum power levels ^ # %
  • 7. Hazardous Location Solutions 4 5 Body Material Pipe Size (in) Orifice Size in (mm) Cv Flow Factor (Kv=m3 /h) Single Solenoid – SIL 3 Capable, Certified by Exida ¨ Watt Rating/ Class of Coil Insulation Operating Pressure Differential psi (bar) Max. Fluid Temp.˚F (˚C) Catalog Number Air-Inert Gas Min. Max. AC Max. DC AC DC AC DC 3-Way EV 8551 Series - NAMUR Mount Spool Valves 316L Stainless Steel 3/2, 5/2 1/4 1/4 (6) .86 (.75) 30 (2) 150 (10) 120 (8.2) 140 (60) 120 (48) EV8551G409 10.1/F 11.6/F ¨ Safety manual and FMEDA (Failure Modes Effects and Diagnostic Analysis) report available. Pipe Size (in) Orifice Size in (mm) Cv Flow Factor (Kv=m3 /h) Operating Pressure Differential psi (bar) Max. Fluid Temp.˚F (˚C) Brass Body Watt Rating/ Class of Coil InsulationMax. AC Max. DC Press. Exh. Inlet Exh. Min. Air-Inert Gas Water Lt. Oil @ 50 SSU Air-Inert Gas Water Lt. Oil @ 50 SSU AC DC Catalog Number AC DC 4-Way EV 8345 Series SINGLE SOLENOID 1/4 1/16 (2) 3/32 (2) .09 (.08) .09 (.08) 10 (.07) 150 (10) 150 (10) 150 (10) 100 (7) 100 (7) 100 (7) 180 (82) 104 (40) EV8345G001 10.1/F 11.6/F 4-Way | General Service 3-Way | General Service 8551 Series • Unique spool design combines hard T-seals and flexible o-rings which provides bubble-tight shutoff, resistance to dirt and sticking, and multimillion cycle life controlling air or inert gas 8345 Series • Compact 4-way valves for low flow applications ^ # % ^ # %
  • 8. Hazardous Location Solutions 4 6 Pipe Size in (mm) Orifice Size in (mm) Cv Flow Factor (Kv=m3 /h) Operating Pressure Differential psi (bar) Ambient Temp. °F (°C) Brass Stainless Watt Rating/ Class of Coil Insulation Min. Max. AC Max. DC Air-Inert Gas Water Light Oil @ 300 SSU Air-Inert Gas Water Light Oil @ 300 SSU Min Max. AC Max. DC AC DC 3/2 VALVES, UNIVERSAL, DIRECT ACTING, BALANCED POPPET 1/4 0.22 (5.7) 0.52 (0.45) 0 (0) 145 (10) 145 (10) - 145 (10) 145 (10) - -4 (-20) 248 (120) 248 (120) NF8327B101 ¨ WSNF8327B102 3.7 3.6 1/4 0.22 (5.7) 0.52 (0.45) 0 (0) 145 (10) 145 (10) - 145 (10) 145 (10) - -58 (-50) 140 (60) 140 (60) NF8327B111 ÂŹ WSNF8327B112 3.7 3.6 ¨ Fluoroelastomer sealings and poppets. ÂŹ Fluorosilicone sealings and poppets. 3/2 VALVES, DIRECT ACTING, UNIVERSAL 1/4 0.13 (3.2) 0.24 (0.21) 0 (0) 49 (3.4) 49 (3.4) 50 (3.4) 25 (1.7) 25 (1.7) 25 (1.4) 32 (0) 126 (52) 104 (40) NF8320B176 WSNF8320A201 17.1 11.6 1/4 0.09 (2.4) 0.12 (0.1) 0 (0) 102 (7) 102 (7) - 58 (4) 58 (4) - -4 (-20) 194 (90) 194 (90) NF8320B174 WSNF8320A200 16.7 11.2 3/2 VALVES, DIRECT ACTING, NORMALLY CLOSED 1/4 0.09 (2.4) 0.12 (0.1) 0 (0) 145 (10) 145 (10) - 116 (8) 116 (8) - -4 (-20) 194 (90) 194 (90) NF8320A184 WSNF8320A202 10.5 11.2 3/2 VALVES, DIRECT ACTING, NORMALLY OPEN 1/4 0.09 (2.4) 0.12 (0.1) 0 (0) 73 (5) 73 (5) - 58 (4) 58 (4) - -4 (-20) 194 (90) 194 (90) NF8320A196 WSNF8320A205 10.5 11.2 1/4 0.09 (2.4) 0.12 (0.1) 0 (0) 145 (10) 145 (10) - 102 (7) 102 (7) - -4 (-20) 194 (90) 194 (90) NF8320A194 WSNF8320A204 10.5 11.2 3/2 VALVES, ZERO MINIMUM, NORMALLY CLOSED 1/4 0.31 (8) 1.5 (1.3) 0 (0) √ 145 (10) - - 116 (8) - - -4 (-20) 176 (80) 176 (80) NF8316A001 ƒ WSNF8316A081V ≈ 10.5 11.2 1/4 0.31 (8) 1.5 (1.3) 0 (0) √ 145 (10) - - 145 (10) - - -4 (-20) 140 (60) 140 (60) NF8316A301 ƒ WSNF8316A381V ≈ 1.8 1.8 3/8 0.31 (8) 1.7 (1.5) 0 (0) √ 145 (10) - - 116 (8) - - -4 (-20) 176 (80) 176 (80) NF8316A002 ƒ WSNF8316A082V ≈ 10.5 11.2 3/8 0.31 (8) 1.7 (1.5) 0 (0) √ 145 (10) - - 145 (10) - - -4 (-20) 140 (60) 140 (60) NF8316A302 ƒ WSNF8316A382V ≈ 1.8 1.8 3/8 0.63 (16) 3.9 (3.4) 0 (0) √ 145 (10) - - 116 (8) - - -4 (-20) 176 (80) 176 (80) NF8316A003 ƒ - 10.5 11.2 3/8 0.63 (16) 3.9 (3.4) 0 (0) √ 145 (10) - - 145 (10) - - -4 (-20) 140 (60) 140 (60) NF8316A303 ƒ - 1.8 1.8 1/2 0.63 (16) 3.9 (3.4) 0 (0) √ 145 (10) - - 116 (8) - - -4 (-20) 176 (80) 176 (80) NF8316A004 ƒ WSNF8316A084V ≈ 10.5 11.2 1/2 0.63 (16) 3.9 (3.4) 0 (0) √ 145 (10) - - 145 (10) - - -4 (-20) 140 (60) 140 (60) NF8316A304 ƒ WSNF8316A384V ≈ 1.8 1.8 √ Zero minimum when valve selection gasket is in external position and proper auxiliary air pressure is applied. Minimum 15 psi (1 bar) operating pressure differential when selection gasket is in the internal position. ƒ Nitrile seal materials. ≈ Fluoroelastomer seal materials. 3/2 VALVES, PILOT OPERATED, SPOOL TYPE, NORMALLY CLOSED 1/4 0.24 (6) 0.87 (0.75) 30 (2) 145 (10) - - 145 (10) - - -13 (-25) 140 (60) 140 (60) NF8551B405 ≤ 10.5 11.2 1/4 0.24 (6) 0.87 (0.75) 30 (2) 145 (10) - - 145 (10) - - -40 (-40) 176 (80) 176 (80) - WSNF8551A413 10.5 11.2 ≤ Aluminum body 3 and 4-Way ATEX Pilot Valves The following valves are not part of the ASCO Express Shipping program. Typical lead times are three weeks or less. Please consult the factory for specific lead times. • Worldwide approvals for use in potentially explosive atmospheres: ATEX, IECEx, INMETRO, TR CU, and NEPSI • Enclosure provided with a 1/2 NPT threaded entry hole for a broad range of cable glands • IP67 ingress protection • Operator can be rotated through 360° to select the most favorable position for cable entry 3-Way ATEX Pilot Valves Pipe Size (in) Orifice Size in (mm) Cv Flow Factor (Kv=m3 /h) Operating Pressure Differential psi (bar) Ambient Temp. °F (°C) Stainless Steel Body Wattage Rating/ Coil Insulation ClassAir/Natural Gas Min. Max. Catalog Number ÂĄPressure Exhaust Pressure Exhaust Min. Max. 12 or 24 VDC NORMALLY CLOSED (Closed when de-energized) 1/4 1/16 (1.6) 3/32 (2.4) 0.08 (0.07) 0.16 (0.14) 0 150 (10) ¨ -4 (-20) 122 (50) EF8320A511 1.3/F ¨ Light Oil @ 300 SSU Max. Pressure 125 psi (8.6 bar). ÂĄ SIL 3 Capable, Certified by Exida Harsh Environment • Designed for harsh, hazardous environments, including offshore applications • Low power consumption suitable for solar panels and PLC/DCS applications ^ # % |
  • 9. Hazardous Location Solutions 4 7 Pipe Size in (mm) Orifice Size in (mm) Cv Flow Factor (Kv=m3 /h) Operating Pressure Differential psi (bar) Ambient Temp. °F (°C) Aluminum Stainless Watt Rating/ Class of Coil Insulation Min. Max. AC Max. DC Air-Inert Gas Water Light Oil @ 300 SSU Air-Inert Gas Water Light Oil @ 300 SSU Min Max. AC Max. DC AC DC 5/2 VALVES, PILOT OPERATED, SPOOL TYPE, SINGLE SOLENOID 1/4 0.24 (6) 0.87 (0.75) 0 (0) 145 (10) - - 145 (10) - - -13 (-25) 140 (60) 140 (60) NF8551B417 - 10.5 11.2 1/4 0.24 (6) 0.87 (0.75) 0 (0) 145 (10) - - 145 (10) - - -13 (-25) 140 (60) 140 (60) NF8551B317 - 1.9 1.9 1/4 0.24 (6) 0.87 (0.75) 0 (0) 145 (10) - - 145 (10) - - -40 (-40) 176 (80) 176 (80) - WSNF8551A421 10.5 11.2 1/4 0.24 (6) 0.87 (0.75) 0 (0) 145 (10) - - 145 (10) - - -40 (-40) 176 (80) 176 (80) - WSNF8551A321 1.9 1.9 5/2 VALVES, PILOT OPERATED, SPOOL TYPE, DUAL SOLENOID 1/4 0.24 (6) 0.87 (0.75) 0 (0) 145 (10) - - 145 (10) - - -13 (-25) 140 (60) 140 (60) NF8551B418 10.5 11.2 1/4 0.24 (6) 0.87 (0.75) 0 (0) 145 (10) - - 145 (10) - - -40 (-40) 176 (80) 176 (80) - WSNF8551A422 10.5 11.2 1/4 0.24 (6) 0.87 (0.75) 0 (0) 145 (10) - - 145 (10) - - -40 (-40) 140 (60) 140 (60) - WSNF8551A322 1.9 1.9 5/2 VALVES, PILOT OPERATED, SPOOL TYPE, SINGLE SOLENOID, NAMUR 1/4 0.24 (6) 0.87 (0.75) 0 (0) 145 (10) - - 145 (10) - - -13 (-25) 140 (60) 140 (60) NF8551B401 - 10.5 11.2 1/4 0.24 (6) 0.7 (0.6) 0 (0) 145 (10) - - 145 (10) - - -40 (-40) 176 (80) 176 (80) - WSNF8551A409 10.5 11.2 1/4 0.24 (6) 0.7 (0.6) 0 (0) 145 (10) - - 145 (10) - - -40 (-40) 176 (80) 176 (80) - WSNF8551A309 1.9 1.9 Pipe Size in (mm) Orifice Size in (mm) Cv Flow Factor (Kv=m3 /h) Operating Pressure Differential psi (bar) Ambient Temp. °F (°C) Brass Stainless Watt Rating/ Class of Coil Insulation Min. Max. AC Max. DC Air-Inert Gas Water Light Oil @ 300 SSU Air-Inert Gas Water Light Oil @ 300 SSU Min Max. AC Max. DC AC DC 3/2 VALVES, MANUAL RESET, NO VOLTAGE RELEASE 1/4 0.22 (5.7) 0.52 (0.45) 0 (0) 145 (10) 145 (10) - 145 (10) 145 (10) - -4 (-20) 248 (120) 248 (120) NF8327B121 WSNF8327B122 3.7 3.6 1/4 0.22 (5.7) 0.52 (0.45) 0 (0) 145 (10) 145 (10) - 145 (10) 145 (10) - -40 (-40) 104 (40) 104 (40) NF8327B171 WSNF8327B172 3.7 3.6 4-Way ATEX Pilot Valves 3-Way ATEX Pilot Valves | Manual Reset EV Explosion-proof Encapsulated Coil JPIS Intrinsically Safe NF Aluminum Epoxy Coated WSNF 316L Stainless Steel Refer to Specification Section AC 120/60, 110/50, 230/50 DC 24V EV 8316G301 24/DC Enclosure Base Catalog Number Voltage ATEX, IECEx NF Aluminum Epoxy Coated WSNF 316L Stainless Steel Refer to Specification Section AC 230/50 DC 24V 22560 NEPSI 26350 INMETRO 18460 TR CU WSNF X 225608327B212 24/DC Enclosure Base Catalog Number VoltageApproval NEPSI, INMETRO, and TR CU (ATEX, IECEx Standard) How to Order The following valves are not part of the ASCO Express Shipping program. Typical lead times are three weeks or less. Please consult the factory for specific lead times.|
  • 10. 8 DEFINITION OF A LOCATION WHERE A POTENTIALLY EXPLOSIVE ATMOSPHERE MAY OCCUR The classification of an installation into distinct zones has two objectives (according to ATEX 1999/92/EC): - To define the categories of equipment used in the zones indicated, provided they are suitable for gases, vapours or mists and/or dusts. - To classify hazardous places into zones to prevent ignition sources and be able to select the correct electrical and non-electrical equipment accordingly. The zones are defined on the basis of the occurrence of explosive gaseous or dusty atmospheres. GAS GROUPS Group II: Equipment intended for use in places with an explosive gas atmosphere other than mines susceptible to firedamp. Group I: Equipment intended for use in mines susceptible to firedamp. Zone Category (ATEX 94/9/EC) Presence of explosive atmospheres zone 0 1 G¨ Continuous, frequent or for long periods Group II zone 1 2 G Intermittent in normal operation (likely) zone 2 3 G Occasional or for short periods (never in normal operation) Group I M1¨ Presence (methane, dust) (mines) M2 Risk of presence (methane, dust) DUST GROUPS (according to the fifth edition, IEC 60079-0, 2011 (EN 60079-0, 2012)ÂĄ ) Group III: Equipment intended for use in places with an explosive dust atmosphere other than mines susceptible to firedamp. Zone Category (ATEX 94/9/EC) Presence of explosive atmospheres zone 20 1 D ¨ Continuous, frequent or for long periods (air/cloud of combustible dust) Group III zone 21 2 D Intermittent in normal operation zone 22 3 D Occasional or for short periods Equipment Group II Industrial Equipment Category 2 High Protection Suitability of Use G Gas Mark for Explosion Proof Protection Method d Flameproof Gas/Dust Group IIC Hydrogen/Acetylene Equipment Protection Level Gb High Protection (Gas) Temperature Code T3 200˚C T4 135˚C T5 100˚C T6 85˚C II 2 G Ex IIC Encapsulation Gasses and Vapors, Dust mb Encapsulation Gasses and Vapors, Dust mbd T3...T6 Temperature Code T200 T135 T100 T85 T85 Gb Equipment Group II Industrial Equipment Category 2 High Protection Suitability of Use D Dust Mark for Explosion Proof Protection By Enclosure tb Dust Gas/Dust Group IIIC Conductive Dust Equipment Protection Level Db High Protection (Dust) Temperature Code 6 Dust Tight 7 Temporary Submersion II 2 D Ex IIICtb IP67Db Safety Code Explained ¨ G = gas ; D = dust ; M = mines ÂĄ Including IEC 61241-0 (dusts) Reference Guide
  • 11. Reference Guide 4 9 Typical Gas/Dust Group Gas Propane IIA Ethylene IIB Acetylene IIC Dust Combustible Fyings IIIA Non-Conductive Dust IIIB Conductive Dust IIIC Level of Protection Against Solid Objects, Materials or Dust Level of Protection Against Water and Other Liquids 0 No protection 0 No protection 1 Protected against solid objects down to 50 mm 1 Protection against vertically fall- ing drops of water (e.g. conden- sation) 2 Protected against solid objects down to 12 mm 2 Protection against direct sprays of water up to 15 degrees from vertical 3 Protected against solid objects down to 2.5 mm 3 Protection against direct sprays of water up to 60 degrees from vertical 4 Protected against solid objects down to 1 mm 4 Protection against water sprayed from all directions - limited in- gress permitted 5 Protected against dust, limited ingress (no harmful deposits) 5 Protection against low pressure jets of water from all directions - limited ingress permitted 6 Totally protected against dust 6 Protection against low pressure jets of water, limited ingress per- mitted (e.g. ship deck) 7 Protected against the effect of immersion between 6 in. / 15 cm and 3 ft / 1m 8 Protected against long periods of immersion under pressure Gas & Dust Groups Ingress Protection (i.e. IP67) Equipment Group Equipment Category Equipment Protection Level (EIC) Level of Protection Hazard Zone (Flammable Material Present) Gas Dust 0 - 20 (Continuosly) 1 - 2 (Intermittently) 2 - 22 (Abnormally) I M 1 Ma Very High - - Operable in Ex atmosphere M 2 Mb High - - De-energized in Ex atmosphere II 1 Ga Very High G - 0 1 2 Da Very High - D 20 21 22 2 Gb High G - - 1 2 Db High - D - 21 22 3 Gc Normal G - - - 2 Dc Normal - D - - 22 Groups, Categories, & Zones (i.e. II 2 G Ex d IIC Gb T6 … T4) Flammable / Combustable Substance Protection Symbol Zones Description0 1 2 Gas d l l Flameproof Enclosure p l l Pressurised enclosure q l l Powdery filling o l l Immersion e l l Increased safety ia/ib/ic l l l Intrinsically safety n l Non incendiaire ma/mb/mc l l l Encapsulation Dust ia l Intrinsically safety tD l Flameproof Enclosure mD l l Encapsulation Protection Methods
  • 12. Reference Guide 4 10 CLASSIFICATION OF GASES INTO EXPLOSION GROUPS Group I: Electrical equipment intended for use in the underground parts of mines, and to those parts of surface installations of such mines, likely to become endangered by firedamp and/or combustible dust. Group II: Electrical equipment intended for use in other places likely to become endangered by explosive atmospheres (surface industries). ¨ Temperature of a hot surface able to ignite a gas mixture. The ignition temperature of the gas mixture must be higher than the maximum surface temperature. In practice, a 10 to 20% safety margin is observed between the ignition temperature and the rated nameplate temperature. The ignition temperature of a cloud of dust is generally between 300 and 700°C. At 150 to 350°C, the ignition temperature of a layer of dust is far below that of a dust cloud. A burning dust layer can initiate a dust explosion if brought in contact with a combustible dust cloud, so these values must be taken into account to limit the risk. CLASSIFICATION OF DUSTS INTO EXPLOSION GROUPS (according to the fifth edition, IEC 60079-0, 2011) Group III: Electrical equipment intended for use in places with an explosive dust atmosphere other than mines susceptible to firedamp. Group III is subdivided into IIIA (combustible flyings), IIIB (non-conductive dust) and IIIC (conductive dust). Combustible dust: Finely divided solid particles, 50 Âľm or less in nominal size, which may be suspended in air, may settle out of the atmosphere under their own weight, may burn or glow in air, and may form explosive mixtures with air at atmos- pheric pressure and normal temperatures. Non-conductive dust: Combustible dust with electrical resistivity greater than 103 Ί.m Conductive dust: Combustible dust with electrical resistivity equal to or less than 103 Ί.m ¨ The maximum surface temperature must be identified and suitable for the specified type of dust present (equipment marked for zone 21). In order to prevent the ignition of dusty atmospheres, the maximum surface temperature needs to be limited. It must not exceed: - 2/3 of the auto-ignition temperature of the specified cloud of dust, - the auto-ignition temperature of a 5 mm layer of dust minus 75°C. Groups Gas Ignition Temperature (°C) ¨ Temperature Class T1 T2 T3 T4 T5 T6 I methane (redamp) II A acetone 540 • acetic acide 485 • ammonia 630 • ethane 515 • methylene chloride 556 • methane (CH4) 537 • carbon monoxyde 605 • propane 470 • n-butane 365 • n-butyl 370 • n-hexane 240 • acetaldehyde 140 • ethyl ether 160 • ethyl nitrite 90 • B ethylene 425 • ethyl oxyde 429-440 • hydrogen sulde 270 • C acetylene (C2H2) 305 • carbon disulphide (CS2) 102 • hydrogen (H2) 560 • Combustible dust Ignition Temperature (˚C) ¨ Self-ignition temperature of dust layers (˚C) ¨ Starch 440 290 Aluminium 530 280 Cotton 560 350 Cereals 420 290 Magnesium 610 410 Soybean 500 245 Sulphur 280 280 Tobacco 450 300
  • 13. Reference Guide 4 11 Valve Parts in Contact with Fluid Valve Series 8262 8320 8327 8316 8551 / 8553 Body 303 SS BR/303 SS BR/316 SS BR 316 SS AL/BR 316 SS Core and Plugnut 430F SS 430F SS 430F SS 430F SS 430F SS 430F SS 430F SS Core Tube 303 SS 303 SS 303 SS 303 SS 303 SS 303 SS 303 SS Disc and Seals Sealings & Poppet (8327) NBR NBR FPM/VMQ/FVMQ NBR NBR NBR/PUR VMQ/PUR Diaphragms (8316) - - - NBR FPM Disc Holder & Core Guide - CA - - - POM POM Springs 303 SS 303 SS 303 SS 303 SS 303 SS 303 SS 303 SS Shading Coil SILVER Copper/Silver - Copper Silver - - Rider Ring - - PTFE PTFE PTFE PTFE PTFE ATEX Wetted Parts Enclosure Type NF WSNF JPIS EV Conduit 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT Solenoid Enclosure Chromated Aluminum epoxy coated 316L Stainless steel Aluminum Epoxy Encapsulated Bonnet Steel (zinc plated) Stainless steel (nickel plated) 430F Stainless steel 416 Stainless steel Core, Core Tube & Plugnut 430F Stainless Steel 430F Stainless steel 430F Stainless steel Shading coil Copper or silver Not Applicable Copper or silver Nameplate Stainless Steel 304 Stainless steel 304 Stainless steel Electrical Connection Screw Terminals Screw Terminals Lead Wires Fasteners and Screws Stainless steel 316 Stainless Steel Not Applicable Materials of construction TEMPERATURE CLASS The temperature classification is based on the maximum surface temperature of equipment. That is the highest temperature any part of or the entire surface of an electrical device can reach under the most unfavorable operating conditions capable of igniting a surrounding explosive atmosphere. Group I: Temperature ≤ 150°C or ≤ 450°C according to coal dust accumulation on equipment Group II: Equipment must be classified and marked: - preferably with the temperature class (T classification) - defined by the surface temperature or, limited to the specified flammable gases or dusts for which it is approved, if necessary (and marked accordingly). Temperature Class Maximum Temperature (˚C) Ignition Temperature (˚C) T1 450 > 450 T2 300 > 300 T3 200 > 200 T4 135 > 135 T5 100 > 100 T6 85 > 85
  • 14. Reference Guide 4 12 Protection Symbol Zones Description Drawing 0 1 2 d e i ia R L CUib ic m ma mb mc n o p q Type of protection in which the parts which can ignite an explosive atmosphere are placed in an enclosure which can withstand the pressure developed during an internal explosion of an explosive mixture and which prevents the transmission of the explosion to the explosive atmospheres surrounding the enclosure. Type of protection in which measures are applied so as to prevent with a higher degree of safety the possibility of exces- sive temperatures and of the occurrence of arcs or sparks in the interior and on the external parts of electrical apparatus, which does not produce them in normal service. Type of protection when no spark or any thermal effect in the circuit, produced in the test conditions prescribed in the standard (which include normal operation and specic fault conditions), is capable of causing ignition. Type of protection in which the parts which can ignite an explosive atmosphere are enclosed in a resin sufciently resistant to the environmental influences in such a way that this explosive atmosphere cannot be ignited by either sparking or heating which may occur within the encapsulation. Method of protection for electrical equipment designed so that it will not ignite the surrounding explosive atmosphere in normal operation and under certain fault conditions specied in the standard. There are 4 categories of equipment: nA (non- sparking), nC (enclosed break), nR (restricted breathing), nL (limited energy). Type of protection in which the electrical apparatus is immersed in oil. Type of protection in which the protective inert gas inside the enclosure is maintained at a higher pressure than that of the surrounding atmosphere. Type of protection in which the enclosure is lled with a material in a nely granulated state. TYPES OF PROTECTION FOR ELECTRICAL APPARATUS FOR USE IN GAS ATMOSPHERES. It is the comprehensive range of protective measures applied to an electrical apparatus to prevent possible ignition of the surrounding atmosphere.
  • 15. Reference Guide 4 13 Protection symbol Zones Description Drawing 0 1 2 tD mD maD mbD iD Electrical apparatus protected by enclosure and surface temperature limitation for use in areas where combustible dust may be present in quantities which could lead to a re or explosion hazard. The ignition protection is based on the limitation of the maximum surface temperature of the enclosure and other surfaces which may come into contact with dust and on the restriction of dust ingress into the enclosure by the use of “dust-tight” or “dust-protected” enclosures. This standard is not applicable to electrical apparatus intended for use in underground parts of mines as well as those parts of surface installations of such mines endangered by redamp and/or combustible dust; nor does it take account of any risk due to an emission of flammable or toxic gas from the dust. Electrical apparatus protected by encapsulation type of protection ‘mD’ and surface temperature limitation for use in areas where combustible dust may be present in quantities which could lead to a re or explosion hazard. Type of protection in which the parts which can ignite an explosive atmosphere are enclosed in a resin sufciently resistant to environmental influences in such a way that a dust cloud or layer cannot be ignited during installation or operation. Intrinsically safe apparatus intended for use in potentially explosive dust cloud or dust layer environments and for associated apparatus that is intended for connection to intrinsically safe circuits which enter such environments. Applicable to electrical apparatus in which the electrical circuits themselves are incapable of causing an explo- sion in the surrounding combustible dust environment. R L CU TYPES OF PROTECTION FOR ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST (EN 60241-0) Applicable to electrical apparatus for use in areas where combustible dust may be present in quantities which could lead to a fire or explosion hazard. EN 61241-1 = tD ; EN 61241-18 = mD ; EN 61241-11 = iD
  • 16. ASCO Valve, Inc. (USA) | Tel (1) 800.972.2726 | www.ascovalve.com | e-mail: info-valve@asco.com 06/15 — V7715 Global Contacts Australia (61) 2-9-451-7077 Brazil (55) 11-4208-1700 Canada (1) 519-758-2700 China (86) 21-3395-0000 Czech Republic (420) 235-090-061 Dubai - UAE (971) 4 811 8200 France (33) 2-37-24-42-24 Germany (49) 7237-9960 India (91) 44-39197300 Italy (39) 02-356931 Japan (81) 798-65-6361 Mexico (52) 55-5809-5640 Netherlands (31) 33-277-7911 Singapore (65) 6556-1100 South Korea (82) 2-3483-1570 Spain (34) 942-87-6100 United Kingdom (44) 1695-713600