testo-6441-6444   05.11.2012     11:34    Seite 1




                                                                                      We measure it.




         Compressed air counter
         DN 15-50
         testo 6441-6444




         Measurement of norm volume flow in the measuring range
         0.25 to 700 m3/h (DN15 to DN50 or ½’’-2’’); consumption
         quantity in m3; media temperature in °C

         Highest flexibility thanks to different signal outputs:
         - Analog output 4 to 20 mA (4-wire)
         - Pulse output
         - 2 switch outputs (parameterisable: consumption or volume
         flow-dependent, opener, closer, hysteresis, window)
                                                                                                                       m 3 /h;
                                                                                                                       l/min;
         Built-in totalizer, even without additional analysis unit                                                       m3


         Operating menu with LED display
                                                                                                                         °C




         The compressed air counters testo 6441 to testo 6444 are     process regarding cost reduction measures and energy
         designed for the measurement, monitoring and recording of    savings. The compressed air counters testo 6441 to testo
         compressed air consumption, and therefore also for the       6444 record norm volume flow according to the calorimetric
         determination of leakages in compressed air systems,         principle, which means the measurement procedure is
         consumption-based allocation of costs and the                independent of the process pressure and does not cause a
         implementation of peak load management. Using the            permanent pressure drop. While the thermal, glass-coated
         compressed air counters testo 6441 to testo 6444,            ceramic sensor offers a high level of robustness and fast
         transparency of consumption is created for compressed air,   response times, the integrated inflow and outflow pipes
         similarly as for the media current, water or gas, thus       ensure optimum accuracy.
         increasing the motivation of those responsible for the




                                                                                                 www.testolimited.com
testo-6441-6444        05.11.2012           11:34         Seite 2




         testo 6441-6444 – Compressed air counter DN 15-50                                                                                   We measure it.




         Technical data


                                                       testo 6441                      testo 6442                          testo 6443              testo 6444
         Measurement parameters
         (Norm) volume flow
         Selectable units                                                                            m3/h; l/min; m3
         Measuring range      (1:300)1              0.25 to 75   m3/h              0.75 to 225    m3/h                 1.3 to 410 m3/h          2.3 to 700 m3/h
         Accuracy                          For compressed air quality classes (ISO 8573: particles-humidity-oil) 1-4-1: ±3 % of meas. value ±0.3 % of final value
         (norm volume flow)                For compressed air quality classes (ISO 8573: particles-humidity-oil) 3-4-4: ±6 % of meas. value ±0,6 % of final value

         Sensor                            Thermal, glass-coated ceramic sensor (calorimetric measurement procedure)
         Response time                     〈 0.1   sec (for damping parameter = 0), delayable via operating menu (0 to 1 sec)
         Temperature
         Unit                                                                                                °C
         Measuring range                                                                          0 to +60 °C / 32 °F to +140 °F


         Inputs and outputs
         Analog outputs
         Output type                                                     4 to 20 mA (4-wire) freely scalable between zero and measuring range end
         Load                                                                                               max. 500 Ω
         Further outputs
         Pulse output                      Consumption quantity counter (value remains available after reset or power cut due to non-volatile memory), value 1 or 10
                                           m3, pulse length 0.02 s to 2 s, 24 VDC level

         Switch output                     2 switch outputs, parameterizable (consumption or volume flow-dependent, opener, closer, hysteresis, window), loadable
                                           with max. 20 to 30 VDC or 250 mA each, switch status is displayed via 2 LEDs

         Supply
         Voltage supply                                                                                    19 to 30 V DC
         Current consumption                                                                                  〈 100   mA
         Connection                        M12 x 1 plug, loadable up to 250 mA, short-circuit-proof (synchronized), reverse-polarity-proof, overload-proof


         General technical data
         Design
         Material housing                                                                  PBT (GF 20%), diecast zinc, silica-free
         Long measurement stretch                       300 mm                                                             475 mm
         Pipe diameter                        DN 15 (for 1/2“ pipes)              DN 25 (for 1“ pipes)            DN 40 (for 1 1/2“ pipes)   DN 50 (for 2“ pipes)


         Weight                                          0.9 kg                          1.1 kg                             3.0 kg                  3.8 kg
         Display
         Material                          4-figure alphanumerical display, two operating buttons, operating menu, LED (4 x green for phys. units, 3 x yellow for
                                           display x 1,000 or switch status)

         Max. display value                             90 m3/h                        270 m3/h                            492 m3/h                840 m3/h
         norm volume flow
         Temperature display                                                       0 to +60 °C, measurement error ±2 K, (+32 to +140 °F)
         Operation
         Parameterization                                                                                2 operating buttons
         Installation
         Measurement stretch:                  R 1/2, outer thread                  R1, outer thread               R1 1/2, outer thread         R2, outer thread
         thread (both sides) /                Stainless steel 1.4301             Stainless steel 1.4301           Stainless steel 1.4401     Stainless steel 1.4401
         material
         Miscellaneous
         Protection class                                                                                     IP 65/III
         EMC                                                                                 according to guideline 89/336 EEC
         Media contact                                           Materials stainless or galvanized steel, PEEK, polyester, Viton, anodized aluminium ceramic

         Operating conditions
         Humidity (sensor)                                                                            re. humidity 〈90 %RH
         Operating temperature (housing)                                                          0 to +60 °C (+32 to +140 °F)
         Storage temperature                                                                      -25 to +85 °C (-13 to +185 °F)
         Measurement medium                                                              Compressed air, on request also CO2 or N2
         Process pressure                                                                          PN 16 (max 16bar/232psi)
         Air quality                                                                      ISO 8573: recommended classes 1-4-1

         1   Specifications according to DIN 2533 (+15 °C, 1013.25 hPa, 0 %RH)
testo-6441-6444    05.11.2012   11:34   Seite 3




         testo 6441-6444 – Compressed air counter DN 15-50   We measure it.




         Technical drawings



          testo 6441




          testo 6442




          testo 6443




          testo 6444
testo-6441-6444     05.11.2012        11:34     Seite 4




         testo 6441-6444 – Compressed air counter DN 15-50                                                                     We measure it.




         Options / Ordering example


          5 options                                 A            B            C              D        E
          DN 15-50




                                                                                                                                                 0981 8354/msp/A/10.2012
                            Define in
                                                                                                    (Switch)
                            menu                (Switch)     (Switch)                              Hno / Hnc
                                                                             ImP *       ImP *
          Output 1                             Hno / Hnc    Hno / Hnc                              Fno / Fnc
                                                                            (Pulse)     (Pulse)        or
          OUT 1                                Fno / Fnc    Fno / Fnc
                                                                                                  ImP (Pulse)

          Output 2
          OUT 2                                                  I                            I
                                               Hno / Hnc                  Hno / Hnc                   ImP
                                               Fno / Fnc                  Fno / Fnc                 (Pulse)
         M12 socket M12 plug on                               Current                   Current
                                                (Switch)                   (Switch)
          on cable   instrument                                signal                    signal

                                        BN                                                                      L + (19 to 30 VDC)


                                        WH
            testo 6441                  OU
                                        T2
              to testo
               6444
                                        BK
                                        OU
          BN =   brown                  T1
          WH =   white                                                                                          0 VDC
                                        BU
          BK =   black
          BU =   blue


                                                 A/C*           A/D*         C/B*        B/D*




                                                                                                                                                 Subject to change without notice.
          * If menu selection ImPR = Yes -> Pulse output
            If menu selection ImPR = No -> Switch output (pre-selection counter)




            Terminal allocation                                                       Wire colours for cable 0699 3393
          1   Supply connection 19 to 30 VDC (+)                                      brown
          2   OUT 2 (analog output (4 to 20 mA) or switch output                      white
          3   Supply connection 0 V (-)                                               blue
          4   OUT 1 (pulse output or switch output)                                   black




         Order data testo 6441 to testo 6444                                                                                          Part no.


           testo 6441 compressed air counter with integrated inflow/outflow, diameter DN15 (1/2),                                    0555 6441
           with analog, pulse and switch output *
           testo 6442 compressed air counter with integrated inflow/outflow, diameter DN25 (1),                                      0555 6442
           with analog, pulse and switch output *
           testo 6443 compressed air counter with integrated inflow/outflow, diameter DN40 (1 1/2),                                  0555 6443
           with analog, pulse and switch output *
           testo 6444 compressed air counter with integrated inflow/outflow, diameter DN50 (2), with analog,                         0555 6444
           pulse and switch output *

         * a connection cable, e.g. part no. 0699 3393, is required for operation




                                                                                                                   www.testolimited.com

Weitere ähnliche Inhalte

Was ist angesagt?

Testo 550 datasheet 2012
Testo 550 datasheet 2012Testo 550 datasheet 2012
Testo 550 datasheet 2012
Testo Limited
 
Guided Wave Radar/LR Level Sensor Brochure
Guided Wave Radar/LR Level Sensor BrochureGuided Wave Radar/LR Level Sensor Brochure
Guided Wave Radar/LR Level Sensor Brochure
ifm electronic gmbh
 
Testo 512 datasheet 2012
Testo 512 datasheet 2012Testo 512 datasheet 2012
Testo 512 datasheet 2012
Testo Limited
 
Testo 314 datasheet 2012
Testo 314 datasheet 2012Testo 314 datasheet 2012
Testo 314 datasheet 2012
Testo Limited
 
Testo 526 datasheet 2012
Testo 526 datasheet 2012Testo 526 datasheet 2012
Testo 526 datasheet 2012
Testo Limited
 

Was ist angesagt? (19)

Thermtest thw-l2
Thermtest thw-l2Thermtest thw-l2
Thermtest thw-l2
 
Isweek lox 02 lumin ox optical oxygen sensor
Isweek lox 02 lumin ox optical oxygen sensor Isweek lox 02 lumin ox optical oxygen sensor
Isweek lox 02 lumin ox optical oxygen sensor
 
Testo 550 datasheet 2012
Testo 550 datasheet 2012Testo 550 datasheet 2012
Testo 550 datasheet 2012
 
Mod mag m2000 datasheet badger meter electromagnetic flow meter_m-series
 Mod mag m2000 datasheet badger meter electromagnetic flow meter_m-series Mod mag m2000 datasheet badger meter electromagnetic flow meter_m-series
Mod mag m2000 datasheet badger meter electromagnetic flow meter_m-series
 
Guided Wave Radar/LR Level Sensor Brochure
Guided Wave Radar/LR Level Sensor BrochureGuided Wave Radar/LR Level Sensor Brochure
Guided Wave Radar/LR Level Sensor Brochure
 
Air quality
Air qualityAir quality
Air quality
 
Oxymax cos41 endress+hauser datasheet-measurement of the dissolved oxygen
Oxymax cos41 endress+hauser datasheet-measurement of the dissolved oxygenOxymax cos41 endress+hauser datasheet-measurement of the dissolved oxygen
Oxymax cos41 endress+hauser datasheet-measurement of the dissolved oxygen
 
Testo 512 datasheet 2012
Testo 512 datasheet 2012Testo 512 datasheet 2012
Testo 512 datasheet 2012
 
Thermtest THW-L1
Thermtest THW-L1Thermtest THW-L1
Thermtest THW-L1
 
Isweek htu20 d digital relative humidity sensor with temperature output 5%acc...
Isweek htu20 d digital relative humidity sensor with temperature output 5%acc...Isweek htu20 d digital relative humidity sensor with temperature output 5%acc...
Isweek htu20 d digital relative humidity sensor with temperature output 5%acc...
 
Magnetostrictive Liquid Level Transmitters
Magnetostrictive Liquid Level TransmittersMagnetostrictive Liquid Level Transmitters
Magnetostrictive Liquid Level Transmitters
 
The right choice for your application. Flow sensors and flow meters from ifm ...
The right choice for your application. Flow sensors and flow meters from ifm ...The right choice for your application. Flow sensors and flow meters from ifm ...
The right choice for your application. Flow sensors and flow meters from ifm ...
 
MID Flow Sensor Brochure
MID Flow Sensor BrochureMID Flow Sensor Brochure
MID Flow Sensor Brochure
 
Dynasonics u500w datasheet badger meter ultrasonic cold water meter_product l...
Dynasonics u500w datasheet badger meter ultrasonic cold water meter_product l...Dynasonics u500w datasheet badger meter ultrasonic cold water meter_product l...
Dynasonics u500w datasheet badger meter ultrasonic cold water meter_product l...
 
Testo 314 datasheet 2012
Testo 314 datasheet 2012Testo 314 datasheet 2012
Testo 314 datasheet 2012
 
Turbimax cus71 d endress+hauser datasheet-ultrasonic interface sensor
Turbimax cus71 d endress+hauser datasheet-ultrasonic interface sensorTurbimax cus71 d endress+hauser datasheet-ultrasonic interface sensor
Turbimax cus71 d endress+hauser datasheet-ultrasonic interface sensor
 
Turbimax cus31 endress+hauser datasheet-turbidity sensor
Turbimax cus31 endress+hauser datasheet-turbidity sensorTurbimax cus31 endress+hauser datasheet-turbidity sensor
Turbimax cus31 endress+hauser datasheet-turbidity sensor
 
Current To Pneumatic Converter for Process Control
Current To Pneumatic Converter for Process ControlCurrent To Pneumatic Converter for Process Control
Current To Pneumatic Converter for Process Control
 
Testo 526 datasheet 2012
Testo 526 datasheet 2012Testo 526 datasheet 2012
Testo 526 datasheet 2012
 

Ähnlich wie Testo - 6441-6444 - Compressed air counter

Testo - 6446-6447 - Compressed air counter
Testo - 6446-6447 - Compressed air counterTesto - 6446-6447 - Compressed air counter
Testo - 6446-6447 - Compressed air counter
Testo Limited
 
Rotronic PF4 Fast Response Differential Pressure & Temperature Measurement Tr...
Rotronic PF4 Fast Response Differential Pressure & Temperature Measurement Tr...Rotronic PF4 Fast Response Differential Pressure & Temperature Measurement Tr...
Rotronic PF4 Fast Response Differential Pressure & Temperature Measurement Tr...
Thorne & Derrick UK
 
Testo 445 datasheet 2012
Testo 445 datasheet 2012Testo 445 datasheet 2012
Testo 445 datasheet 2012
Testo Limited
 
Testo 635 datasheet 2012
Testo 635 datasheet 2012Testo 635 datasheet 2012
Testo 635 datasheet 2012
Testo Limited
 

Ähnlich wie Testo - 6441-6444 - Compressed air counter (20)

Testo - 6446-6447 - Compressed air counter
Testo - 6446-6447 - Compressed air counterTesto - 6446-6447 - Compressed air counter
Testo - 6446-6447 - Compressed air counter
 
Dynasonics dxn datasheet badger meter portable clamp-on ultrasonic flow meter
Dynasonics dxn datasheet badger meter portable clamp-on ultrasonic flow meterDynasonics dxn datasheet badger meter portable clamp-on ultrasonic flow meter
Dynasonics dxn datasheet badger meter portable clamp-on ultrasonic flow meter
 
RBFM Clamp-on Ultrsonic Flow Meter/ Heat Meter Catalog
RBFM Clamp-on Ultrsonic Flow Meter/ Heat Meter CatalogRBFM Clamp-on Ultrsonic Flow Meter/ Heat Meter Catalog
RBFM Clamp-on Ultrsonic Flow Meter/ Heat Meter Catalog
 
How to select the most suitable flow meter for your application's gas flow me...
How to select the most suitable flow meter for your application's gas flow me...How to select the most suitable flow meter for your application's gas flow me...
How to select the most suitable flow meter for your application's gas flow me...
 
ECD Model T23 pH, ORP, Specific Ion, Dissolved Oxygen, Conduc􏰁tivity Transmit...
ECD Model T23 pH, ORP, Specific Ion, Dissolved Oxygen, Conduc􏰁tivity Transmit...ECD Model T23 pH, ORP, Specific Ion, Dissolved Oxygen, Conduc􏰁tivity Transmit...
ECD Model T23 pH, ORP, Specific Ion, Dissolved Oxygen, Conduc􏰁tivity Transmit...
 
Rotronic PF4 Fast Response Differential Pressure & Temperature Measurement Tr...
Rotronic PF4 Fast Response Differential Pressure & Temperature Measurement Tr...Rotronic PF4 Fast Response Differential Pressure & Temperature Measurement Tr...
Rotronic PF4 Fast Response Differential Pressure & Temperature Measurement Tr...
 
Air Flow meter in India | Air Flow meter - Addmas Measurement
Air Flow meter in India | Air Flow meter - Addmas MeasurementAir Flow meter in India | Air Flow meter - Addmas Measurement
Air Flow meter in India | Air Flow meter - Addmas Measurement
 
Datasheet Fluke 718 Ex. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke 718 Ex. Hubungi PT. Siwali Swantika 021-45850618Datasheet Fluke 718 Ex. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke 718 Ex. Hubungi PT. Siwali Swantika 021-45850618
 
Magnetic flow meter for industrial process measurement
Magnetic flow meter for industrial process measurementMagnetic flow meter for industrial process measurement
Magnetic flow meter for industrial process measurement
 
Calibration Laboratory In India - FARE Labs Pvt. Ltd.
Calibration Laboratory In India - FARE Labs Pvt. Ltd.Calibration Laboratory In India - FARE Labs Pvt. Ltd.
Calibration Laboratory In India - FARE Labs Pvt. Ltd.
 
K Tek Analytics, Mumbai, Balances & Analytical Instruments
K Tek Analytics, Mumbai, Balances & Analytical InstrumentsK Tek Analytics, Mumbai, Balances & Analytical Instruments
K Tek Analytics, Mumbai, Balances & Analytical Instruments
 
Ktekanalytics
KtekanalyticsKtekanalytics
Ktekanalytics
 
Datasheet Fluke 572-2. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke 572-2. Hubungi PT. Siwali Swantika 021-45850618Datasheet Fluke 572-2. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke 572-2. Hubungi PT. Siwali Swantika 021-45850618
 
Dual orifice constant flow bubbler datasheet
Dual orifice constant flow bubbler datasheetDual orifice constant flow bubbler datasheet
Dual orifice constant flow bubbler datasheet
 
Testo 445 datasheet 2012
Testo 445 datasheet 2012Testo 445 datasheet 2012
Testo 445 datasheet 2012
 
Lutron The Art of Measurement Testing Measuring Instruments ROnexbd 2019
Lutron The Art of Measurement Testing Measuring Instruments ROnexbd 2019Lutron The Art of Measurement Testing Measuring Instruments ROnexbd 2019
Lutron The Art of Measurement Testing Measuring Instruments ROnexbd 2019
 
Lutron Short Form 2018
Lutron Short Form 2018 Lutron Short Form 2018
Lutron Short Form 2018
 
MHC-3000 Handheld ultrasonic flow meter data sheet
MHC-3000 Handheld ultrasonic flow meter data sheetMHC-3000 Handheld ultrasonic flow meter data sheet
MHC-3000 Handheld ultrasonic flow meter data sheet
 
Testo 635 datasheet 2012
Testo 635 datasheet 2012Testo 635 datasheet 2012
Testo 635 datasheet 2012
 
Sierra Flowmeters
Sierra FlowmetersSierra Flowmeters
Sierra Flowmeters
 

Mehr von Testo Limited

Testo - STA guide - Feb 2014
Testo - STA guide - Feb 2014Testo - STA guide - Feb 2014
Testo - STA guide - Feb 2014
Testo Limited
 
Testo - Plant and Works Engineering - Feb 2014
Testo - Plant and Works Engineering - Feb 2014Testo - Plant and Works Engineering - Feb 2014
Testo - Plant and Works Engineering - Feb 2014
Testo Limited
 
Testo - PHPI - Feb 2014
Testo - PHPI - Feb 2014Testo - PHPI - Feb 2014
Testo - PHPI - Feb 2014
Testo Limited
 
Testo - PHAM News - Feb 2014
Testo - PHAM News - Feb 2014Testo - PHAM News - Feb 2014
Testo - PHAM News - Feb 2014
Testo Limited
 
Testo - Industrial Plant and Equipment - Feb 2014
Testo - Industrial Plant and Equipment - Feb 2014Testo - Industrial Plant and Equipment - Feb 2014
Testo - Industrial Plant and Equipment - Feb 2014
Testo Limited
 
Testo - Heating Ventillation and Plumbing - Feb 2014
Testo - Heating Ventillation and Plumbing - Feb 2014Testo - Heating Ventillation and Plumbing - Feb 2014
Testo - Heating Ventillation and Plumbing - Feb 2014
Testo Limited
 
Testo - Heating and Ventillation Review - Feb 2014
Testo - Heating and Ventillation Review - Feb 2014Testo - Heating and Ventillation Review - Feb 2014
Testo - Heating and Ventillation Review - Feb 2014
Testo Limited
 
Testo - Food and Drink Network UK - Feb 2014
Testo - Food and Drink Network UK - Feb 2014Testo - Food and Drink Network UK - Feb 2014
Testo - Food and Drink Network UK - Feb 2014
Testo Limited
 
Testo - Food and Drink International - Feb 2014
Testo - Food and Drink International - Feb 2014Testo - Food and Drink International - Feb 2014
Testo - Food and Drink International - Feb 2014
Testo Limited
 
Testo - Environment and Energy Management - Feb 2014
Testo - Environment and Energy Management - Feb 2014Testo - Environment and Energy Management - Feb 2014
Testo - Environment and Energy Management - Feb 2014
Testo Limited
 
Testo - Registered Gas Engineer - Feb 2014
Testo - Registered Gas Engineer - Feb 2014Testo - Registered Gas Engineer - Feb 2014
Testo - Registered Gas Engineer - Feb 2014
Testo Limited
 
Testo (PWE) Jan 2014
Testo (PWE) Jan 2014Testo (PWE) Jan 2014
Testo (PWE) Jan 2014
Testo Limited
 
Testo (plumbing and heating NI) Jan 2014
Testo (plumbing and heating NI) Jan 2014Testo (plumbing and heating NI) Jan 2014
Testo (plumbing and heating NI) Jan 2014
Testo Limited
 
Testo (PHAM news) Jan 2014
Testo (PHAM news) Jan 2014Testo (PHAM news) Jan 2014
Testo (PHAM news) Jan 2014
Testo Limited
 
Testo (mepca) Jan 2014
Testo (mepca) Jan 2014Testo (mepca) Jan 2014
Testo (mepca) Jan 2014
Testo Limited
 
Testo (meat management) Jan 2014
Testo (meat management) Jan 2014Testo (meat management) Jan 2014
Testo (meat management) Jan 2014
Testo Limited
 
Testo (laboratory news) Jan 2014
Testo (laboratory news) Jan 2014Testo (laboratory news) Jan 2014
Testo (laboratory news) Jan 2014
Testo Limited
 
Testo (Connecting Industry instrumentation) Jan 2014
Testo (Connecting Industry instrumentation) Jan 2014Testo (Connecting Industry instrumentation) Jan 2014
Testo (Connecting Industry instrumentation) Jan 2014
Testo Limited
 
Testo (installer) Jan 2014
Testo (installer) Jan 2014Testo (installer) Jan 2014
Testo (installer) Jan 2014
Testo Limited
 

Mehr von Testo Limited (20)

Cloud based monitoring
Cloud based monitoringCloud based monitoring
Cloud based monitoring
 
Testo - STA guide - Feb 2014
Testo - STA guide - Feb 2014Testo - STA guide - Feb 2014
Testo - STA guide - Feb 2014
 
Testo - Plant and Works Engineering - Feb 2014
Testo - Plant and Works Engineering - Feb 2014Testo - Plant and Works Engineering - Feb 2014
Testo - Plant and Works Engineering - Feb 2014
 
Testo - PHPI - Feb 2014
Testo - PHPI - Feb 2014Testo - PHPI - Feb 2014
Testo - PHPI - Feb 2014
 
Testo - PHAM News - Feb 2014
Testo - PHAM News - Feb 2014Testo - PHAM News - Feb 2014
Testo - PHAM News - Feb 2014
 
Testo - Industrial Plant and Equipment - Feb 2014
Testo - Industrial Plant and Equipment - Feb 2014Testo - Industrial Plant and Equipment - Feb 2014
Testo - Industrial Plant and Equipment - Feb 2014
 
Testo - Heating Ventillation and Plumbing - Feb 2014
Testo - Heating Ventillation and Plumbing - Feb 2014Testo - Heating Ventillation and Plumbing - Feb 2014
Testo - Heating Ventillation and Plumbing - Feb 2014
 
Testo - Heating and Ventillation Review - Feb 2014
Testo - Heating and Ventillation Review - Feb 2014Testo - Heating and Ventillation Review - Feb 2014
Testo - Heating and Ventillation Review - Feb 2014
 
Testo - Food and Drink Network UK - Feb 2014
Testo - Food and Drink Network UK - Feb 2014Testo - Food and Drink Network UK - Feb 2014
Testo - Food and Drink Network UK - Feb 2014
 
Testo - Food and Drink International - Feb 2014
Testo - Food and Drink International - Feb 2014Testo - Food and Drink International - Feb 2014
Testo - Food and Drink International - Feb 2014
 
Testo - Environment and Energy Management - Feb 2014
Testo - Environment and Energy Management - Feb 2014Testo - Environment and Energy Management - Feb 2014
Testo - Environment and Energy Management - Feb 2014
 
Testo - Registered Gas Engineer - Feb 2014
Testo - Registered Gas Engineer - Feb 2014Testo - Registered Gas Engineer - Feb 2014
Testo - Registered Gas Engineer - Feb 2014
 
Testo (PWE) Jan 2014
Testo (PWE) Jan 2014Testo (PWE) Jan 2014
Testo (PWE) Jan 2014
 
Testo (plumbing and heating NI) Jan 2014
Testo (plumbing and heating NI) Jan 2014Testo (plumbing and heating NI) Jan 2014
Testo (plumbing and heating NI) Jan 2014
 
Testo (PHAM news) Jan 2014
Testo (PHAM news) Jan 2014Testo (PHAM news) Jan 2014
Testo (PHAM news) Jan 2014
 
Testo (mepca) Jan 2014
Testo (mepca) Jan 2014Testo (mepca) Jan 2014
Testo (mepca) Jan 2014
 
Testo (meat management) Jan 2014
Testo (meat management) Jan 2014Testo (meat management) Jan 2014
Testo (meat management) Jan 2014
 
Testo (laboratory news) Jan 2014
Testo (laboratory news) Jan 2014Testo (laboratory news) Jan 2014
Testo (laboratory news) Jan 2014
 
Testo (Connecting Industry instrumentation) Jan 2014
Testo (Connecting Industry instrumentation) Jan 2014Testo (Connecting Industry instrumentation) Jan 2014
Testo (Connecting Industry instrumentation) Jan 2014
 
Testo (installer) Jan 2014
Testo (installer) Jan 2014Testo (installer) Jan 2014
Testo (installer) Jan 2014
 

Testo - 6441-6444 - Compressed air counter

  • 1. testo-6441-6444 05.11.2012 11:34 Seite 1 We measure it. Compressed air counter DN 15-50 testo 6441-6444 Measurement of norm volume flow in the measuring range 0.25 to 700 m3/h (DN15 to DN50 or ½’’-2’’); consumption quantity in m3; media temperature in °C Highest flexibility thanks to different signal outputs: - Analog output 4 to 20 mA (4-wire) - Pulse output - 2 switch outputs (parameterisable: consumption or volume flow-dependent, opener, closer, hysteresis, window) m 3 /h; l/min; Built-in totalizer, even without additional analysis unit m3 Operating menu with LED display °C The compressed air counters testo 6441 to testo 6444 are process regarding cost reduction measures and energy designed for the measurement, monitoring and recording of savings. The compressed air counters testo 6441 to testo compressed air consumption, and therefore also for the 6444 record norm volume flow according to the calorimetric determination of leakages in compressed air systems, principle, which means the measurement procedure is consumption-based allocation of costs and the independent of the process pressure and does not cause a implementation of peak load management. Using the permanent pressure drop. While the thermal, glass-coated compressed air counters testo 6441 to testo 6444, ceramic sensor offers a high level of robustness and fast transparency of consumption is created for compressed air, response times, the integrated inflow and outflow pipes similarly as for the media current, water or gas, thus ensure optimum accuracy. increasing the motivation of those responsible for the www.testolimited.com
  • 2. testo-6441-6444 05.11.2012 11:34 Seite 2 testo 6441-6444 – Compressed air counter DN 15-50 We measure it. Technical data testo 6441 testo 6442 testo 6443 testo 6444 Measurement parameters (Norm) volume flow Selectable units m3/h; l/min; m3 Measuring range (1:300)1 0.25 to 75 m3/h 0.75 to 225 m3/h 1.3 to 410 m3/h 2.3 to 700 m3/h Accuracy For compressed air quality classes (ISO 8573: particles-humidity-oil) 1-4-1: ±3 % of meas. value ±0.3 % of final value (norm volume flow) For compressed air quality classes (ISO 8573: particles-humidity-oil) 3-4-4: ±6 % of meas. value ±0,6 % of final value Sensor Thermal, glass-coated ceramic sensor (calorimetric measurement procedure) Response time 〈 0.1 sec (for damping parameter = 0), delayable via operating menu (0 to 1 sec) Temperature Unit °C Measuring range 0 to +60 °C / 32 °F to +140 °F Inputs and outputs Analog outputs Output type 4 to 20 mA (4-wire) freely scalable between zero and measuring range end Load max. 500 Ω Further outputs Pulse output Consumption quantity counter (value remains available after reset or power cut due to non-volatile memory), value 1 or 10 m3, pulse length 0.02 s to 2 s, 24 VDC level Switch output 2 switch outputs, parameterizable (consumption or volume flow-dependent, opener, closer, hysteresis, window), loadable with max. 20 to 30 VDC or 250 mA each, switch status is displayed via 2 LEDs Supply Voltage supply 19 to 30 V DC Current consumption 〈 100 mA Connection M12 x 1 plug, loadable up to 250 mA, short-circuit-proof (synchronized), reverse-polarity-proof, overload-proof General technical data Design Material housing PBT (GF 20%), diecast zinc, silica-free Long measurement stretch 300 mm 475 mm Pipe diameter DN 15 (for 1/2“ pipes) DN 25 (for 1“ pipes) DN 40 (for 1 1/2“ pipes) DN 50 (for 2“ pipes) Weight 0.9 kg 1.1 kg 3.0 kg 3.8 kg Display Material 4-figure alphanumerical display, two operating buttons, operating menu, LED (4 x green for phys. units, 3 x yellow for display x 1,000 or switch status) Max. display value 90 m3/h 270 m3/h 492 m3/h 840 m3/h norm volume flow Temperature display 0 to +60 °C, measurement error ±2 K, (+32 to +140 °F) Operation Parameterization 2 operating buttons Installation Measurement stretch: R 1/2, outer thread R1, outer thread R1 1/2, outer thread R2, outer thread thread (both sides) / Stainless steel 1.4301 Stainless steel 1.4301 Stainless steel 1.4401 Stainless steel 1.4401 material Miscellaneous Protection class IP 65/III EMC according to guideline 89/336 EEC Media contact Materials stainless or galvanized steel, PEEK, polyester, Viton, anodized aluminium ceramic Operating conditions Humidity (sensor) re. humidity 〈90 %RH Operating temperature (housing) 0 to +60 °C (+32 to +140 °F) Storage temperature -25 to +85 °C (-13 to +185 °F) Measurement medium Compressed air, on request also CO2 or N2 Process pressure PN 16 (max 16bar/232psi) Air quality ISO 8573: recommended classes 1-4-1 1 Specifications according to DIN 2533 (+15 °C, 1013.25 hPa, 0 %RH)
  • 3. testo-6441-6444 05.11.2012 11:34 Seite 3 testo 6441-6444 – Compressed air counter DN 15-50 We measure it. Technical drawings testo 6441 testo 6442 testo 6443 testo 6444
  • 4. testo-6441-6444 05.11.2012 11:34 Seite 4 testo 6441-6444 – Compressed air counter DN 15-50 We measure it. Options / Ordering example 5 options A B C D E DN 15-50 0981 8354/msp/A/10.2012 Define in (Switch) menu (Switch) (Switch) Hno / Hnc ImP * ImP * Output 1 Hno / Hnc Hno / Hnc Fno / Fnc (Pulse) (Pulse) or OUT 1 Fno / Fnc Fno / Fnc ImP (Pulse) Output 2 OUT 2 I I Hno / Hnc Hno / Hnc ImP Fno / Fnc Fno / Fnc (Pulse) M12 socket M12 plug on Current Current (Switch) (Switch) on cable instrument signal signal BN L + (19 to 30 VDC) WH testo 6441 OU T2 to testo 6444 BK OU BN = brown T1 WH = white 0 VDC BU BK = black BU = blue A/C* A/D* C/B* B/D* Subject to change without notice. * If menu selection ImPR = Yes -> Pulse output If menu selection ImPR = No -> Switch output (pre-selection counter) Terminal allocation Wire colours for cable 0699 3393 1 Supply connection 19 to 30 VDC (+) brown 2 OUT 2 (analog output (4 to 20 mA) or switch output white 3 Supply connection 0 V (-) blue 4 OUT 1 (pulse output or switch output) black Order data testo 6441 to testo 6444 Part no. testo 6441 compressed air counter with integrated inflow/outflow, diameter DN15 (1/2), 0555 6441 with analog, pulse and switch output * testo 6442 compressed air counter with integrated inflow/outflow, diameter DN25 (1), 0555 6442 with analog, pulse and switch output * testo 6443 compressed air counter with integrated inflow/outflow, diameter DN40 (1 1/2), 0555 6443 with analog, pulse and switch output * testo 6444 compressed air counter with integrated inflow/outflow, diameter DN50 (2), with analog, 0555 6444 pulse and switch output * * a connection cable, e.g. part no. 0699 3393, is required for operation www.testolimited.com