Optical Coherance Tomography (OCT) in Vitreo Retina and Choroid
1. Optical CoherenceTomography (OCT)
InVitreo Retina and Choroid
where we are and where we are going in 2017.
Dr. Abdul Sami Memon
MD. FCPS. MCPS.
Fellow of University of California Irvine , USA (Vitreo Retina)
Assistant Professor Isra Postgraduate Institute of Ophthalmology, Karachi.
Consultant Eye Surgeon , Hashmanies Hospital , Karachi.
Clinical and Academic Coordinator Isra Postgraduate Institute of Ophthalmology,
Karachi.
3. Jay S. Duker , M.D.
Baruch D . Kuppermann M.D.
Prof P.S. Mahar
Dr. Rehman Siddique
Dr. Nasir Memon
Bruno Lumbroso, MD, Marco Rispoli, M.D
Adil El Maftouhi, Lyon, France
NICOLAS IAFE M.D
NOPASAK PHASUKKIJWATANA M.D
Richard Rosen, MD
Mrs. Fender and Mrs. Dutch UCI, UCLA
Optuvue
4. Retinal imaging – Where we stand in 2017
Color Fundus Photography – great for documentation.
Fluorescein Angiography – utility in common macular diseases
questionable – has evolved to be largely a test of the retinal
periphery
ICG Angiography – limited availability and utility
5. OCT –The most important ancillary test in the diagnosis and
management of retinal diseases
OCTA -The most important ancillary test in the
diagnosis and management of retinal diseases also.
7. SS OCT
The swept-source is unique light source,
has a wavelength centered at 1 µm that
sweeps across a narrow band of light
source
The SS-OCT utilizes a point
Photodetector, to detect the light waves
returning to the device
Longer wavelength : 1050Nm
Improved immunity in media opacity
Improved visualization of choroid, Sclera
Uniform image quality
SDOCT
The spectral-domain devices utilize a
broadband light source
The SD-OCT uses a spectrometer,
Fourier transform lens, and a line
scan camera.
Enhanced depth imaging : using
image averaging
11. Macular cube scan
Raster Scans:
Radial Scans:
Mesh scan ( vertical and horizontal scan over the area of interest )
Line scan
Line, Cross-Line and Raster Scans, multiline,
Macular Maps (cube scan data or radial scans).
Numeric displays
Color-coded displays
Topographical maps
12. C-Scans (En Face Images),This image looks like a red-free
image of the retina and is obtained by summation of data
from all the B-scans.
MICHAEL HEIFERMAN, MD • JOSEPH SIMONETT, BS • AMANI FAWZI, MD
June 1, 2015
35. Vignetting :This occurs
when a part of the OCT
beam is blocked
Misalignment :This occurs
when the fovea is not
properly aligned during a
volumetric scan.
Fovea
36. Software breakdown :
Software breakdown results
from misidentification of the
inner or outer retinal
boundaries.
37. Blink artifact :
Motion artifact :
Out of range :
Blink
Double
fovea
Out of range
38. OCT –The most important ancillary test in the diagnosis and
management of retinal diseases
39. Summary
Non- invasive , fast and repeatable
Software enhancement in the future will increase the sensivity and
specificity of OCT
SS- OCT will allow for increased field of view and wide field imaging
homogeneous infiltration of the choroid causing an irregular, dome-shaped elevation of the overlying retinal pigment epithelium and retina. There is also infiltration of the subretinal space with a homogeneous material of medium reflectivity and associated subretinal fluid.