International Montoro Resources Inc. (IMTFF- USA) (IMT -TSXV) (O4T1-Frankfurt) Serpent River,"Pecors" Nickel, Copper, PGE Anomoly 2D ZTEM Inversion Results with 3D inversion graphics.
Ähnlich wie International Montoro Resources Inc. (IMTFF- USA) (IMT -TSXV) (O4T1-Frankfurt) Serpent River,"Pecors" Nickel, Copper, PGE Anomoly 2D ZTEM Inversion Results with 3D inversion graphics.
SPICE MODEL of SSM3K36FS (Professional+BDP Model) in SPICE PARKTsuyoshi Horigome
Ähnlich wie International Montoro Resources Inc. (IMTFF- USA) (IMT -TSXV) (O4T1-Frankfurt) Serpent River,"Pecors" Nickel, Copper, PGE Anomoly 2D ZTEM Inversion Results with 3D inversion graphics. (20)
Osisko Development - Investor Presentation - May 2024
International Montoro Resources Inc. (IMTFF- USA) (IMT -TSXV) (O4T1-Frankfurt) Serpent River,"Pecors" Nickel, Copper, PGE Anomoly 2D ZTEM Inversion Results with 3D inversion graphics.
1. 2D ZTEM Inversion Results
for
International Montoro Resources Inc.
Serpent River Property
Elliot Lake, Ontario, Canada
Project: GL160353
By
Geotech Ltd.
245 Industrial Parkway North
Aurora, Ont., CANADA, L4G 4C4
Tel: 1.905.841.5004
Fax: 1.905.841.0611
www.geotech.ca
Email: info@geotech.ca
August, 2017
2. Summary
• Geotech Av2dtopo program was used to perform the inversion with topography and
bird altitude effects considered.
• Total of 28 lines were inverted with frequency range 90Hz to 720Hz using a 5000
ohm-m start model.
• Resistivity range is limited within the inversion code from 1 to 100k Ω.m.
• Vertical cell size is constant (20m) within topography and then geometrically
increases with depth. Horizontal cell size varies from line to line due to the length
difference. Each line counts 192 inverted observed points, 440 horizontal cells and
112 vertical cells in total. The relevant cell dimension is shown in every inversion
results slide.
• Slide 3 shows line locations over IP 180Hz DT image and over Analytic Signal (ASIG)
image.
• Slide 4 shows line locations over DEM image and over PLM image.
• Slides 5 to 9 show 3D views of the inversion results.
• Slides 10 to 38 show the inversion results, the inversion parameters, and the location
of each inversion over IP 180Hz DT image.
• Slides 39 to 55 show resistivity depth slices from 0m to 1500 m at an interval of 100
m.
• The dashed lines in the resistivity cross sections indicate 1.5 x MT skin depth at
30Hz, which is a maximum depth of investigation (DOI) estimate (Spies, 1989) for
the ZTEM inversion model.
• Blank areas on the sections indicates regions severely affected by power-line signal;
Therefore, data have been windowed prior to 2D inversion in order to reduce the
potential effects of anthropogenic Influence.