Ceramic Chimney Liners
SAP 940003679 - September 2022
The cost effective way for housebuilders
to add a safe chimney to their developments
and reduce gas bills
SECONDARY
HEATING
2
Resistant to temperature change
The liners are extremely durable and have been tested for resistance to soot fire as
well as to condensate, and meet the latest CE standards and Construction Product
Regulation (CPR).
Cost effective and reduces gas heating bills
Ideal for homes where you require a cost effective, safe and easy to construct system.
Usage of a log burning stove reduces the need to heat homes with radiators, therefore
less reliance on increasing gas heating bills.
Lightweight
Due to advanced manufacturing techniques, we have been able to reduce the wall
thickness of the liner to produce the optimal lightweight but extremely robust product
which is natural and environmentally friendly.
Other great features of using ceramic liners:
„ Suitable for all fuels – gas, oil, solid fuels and biomass fuels.
„ Wide range of accessories to suit numerous installations.
„ Suitable for high temperature and low temperature applications.
„ Full compliance to the latest CE standards and Construction Products Regulations (CPR).
Using correctly sized liners for new chimneys
„ Flexible flue liners should be used only to RELINE a chimney and should not be used in a new
chimney, which means that ceramic is a cost effective and legal solution.
Ceramic Flue Liners
CERAMIC LINERS
CHOOSING THE CORRECT LINER SIZE
FOR NEW CHIMNEYS.
225mm
concrete liner
Costly and avoidable
steel liner
Correctly sized
ceramic liner
“New masonry chimneys should be
constructed with flue liners suitable
for the intended application”.
3
Approvals
Rapid
Joint detail
„ Liners are installed with the male spigot pointing downwards.
„ Sealant should be applied to the inside of the socket uppermost and any excess projecting into the
flue should be wiped off as installation progresses.
Rapid
Direction of
flue gases
Schiedel Ceramic Liners are CE Certified to EN 1457-1 & 2
TÜV 0780 CPD 131086 with the following designations:
* When used on T200 rated low temperature systems, the liner system should be straight and fully ventilated.
High Temperature Applications Low Temperature Applications
EN 1457-1
A1 N1 (T600 N1 G)
EN 1457-2
B4 N1 (T400 N1 WC O)
D4 N1 (T200 N1 WC O)*
Ceramic Flue Liners
Chimney pots
Schiedel Chimney Systems provide a high
performance chimney pot to finish any
building.
Available in Buff or Terracotta – a chimney
pot can add a decorative charm and appeal
to an otherwise ordinary chimney stack.
Manufactured in accordance with BS EN
13502 : 2002.
Apply Schiedel Rapid
Cement into the
socket of the flue
liner as shown.
4
Liners
A
30˚
B
A
37.5˚
B
A
45˚
B
A
A
C
B
A
B
A
C
B
A
C
B
130
A
Liner
Int Ømm 160 180 200
Ext Ø 190 210 230
A 330 330 330
Weight 5.8 6.3 7.1
Pallet Qty 125 100 75
SAP Code 100374 100375 100376
30˚ Bend
Int Ømm 160 180 200
Ext Ø 190 210 230
A 189 192 194
B 189 192 194
Weight 5.8 6.3 7.1
SAP Code 131625 131626 131627
15˚ Bend
Int Ømm 160 180 200
Ext Ø 190 - 230
A 178.6 - 178.6
B 178.6 - 178.6
Weight - 6.91
SAP Code 131856 - 133899
45˚ Bend
Int Ømm 160 180 200
Ext Ø 190 - 230
A 203 - 211
B 203 - 211
Weight 5.8 - 7.1
SAP Code 131622 - 131624
37.5˚ Bend
Int Ømm 160 180 200
Ext Ø 190 210 230
A 194 199 202
B 196 199 202
Weight 5.8 6.3 7.1
SAP Code 121334 121335 121336
Outer Soot Door
Int Ømm 160 180 200
Ext Ø 190 210 230
A 400 400 400
B 250 250 250
SAP Code 100475 100475 100475
Inspection Pipe with Inner Soot
Door
Int Ømm 160 180 200
Ext Ø 190 210 230
A 660 660 660
B 165 165 165
C 295 295 295
Weight 14 15 17
SAP Code 100428 100429 100430
90˚ Tee Liner
Int Ømm 160 180 200
Ext Ø 190 210 230
A 660 660 660
B 331 331 331
C 175 190 195
Weight 14 15 16
SAP Code 100420 100421 100422
135˚ Tee Liner
Int Ømm 160 180 200
Ext Ø 190 210 230
A 660 660 660
B 463 481 497
C 311 326 357
Weight 16 18 19
SAP Code 100424 100425 100426
Steel collars (for cut joints)
Int Ømm 160 180 200
SAP Code 158122 - 158123
Adaptor from Steel to Ceramic T
Liner
Int Ømm 160 180 200
Ext Ø 190 210 230
Ø Steel (A) 150 175 200
SAP Code 132667 132668 132669
B
A
15˚
5
130
A
130
A
Components
Lintels are used in pairs to support the weight of the support block and liners as an alternative to a cast slab. On a clear span of
up to 1.2m a load of up to 3250Kg can be supported.
Rapid
A
B A
200
280
A
340
340
ØA
1500
140
140
Adaptor from Steel to Support
Block
Int Ømm 160 180 200
Ext Ø 190 210 230
Ø Steel (A) 150 175 200
SAP Code 126373 126499 127691
Increasing Adaptor from Steel to
Support Block (with rope)
Int Ømm 160 180 200
Ext Ø 190 210 230
Ø Steel (A) 125 150 150
SAP Code 126357 126493 127671
Support Blocks
Int Ømm 160 180 200
Ext Ø 190 210 230
Weight 7 8 8
SAP Code 126366 126483 127340
Support Plate
Int Ømm 160 180 200
Ext Ø 340 360 360
SAP Code 127694 128549 128549
Rapid High Temperature Joint
Sealant
Size ml 310
SAP Code 100020
Support Lintel
Size mm 140x140
Length mm 1500
Weight kg 71
SAP Code 146431
Support Lintel
Size mm 100 x 65
Length mm 600
Weight kg 9
SAP Code 169330
Base Stone with Drain
Int Ømm 160 180 200
A 170 170 170
B 70 70 70
SAP Code 102984 102685 10686
Light Expanded Clay Aggregate
Backfill Insulation (50 litre)
Size m3
0.05
Weight kg 19
SAP Code 130769
Topguard (Buff and Terracotta
options)
Int Ømm 150-250
A 300
SAP Code Buff 130742
SAP Code T'cotta 130737
Chimney Pot (Buff and Terracotta
options)
Int Ømm 150 200
A 450 450
SAP Code Buff 126370 130697
SAP Code T'cotta 126371 127341
Chimney Notice Plate
SAP Code 130696
6
FREE STANDING STOVE OPTION
45˚ Tee liner
Wall Sleeve
Trim Collar
Soot Door
Base Stone
with Drain
Inspection Pipe
Tee Liner and
Steel Adaptor
Prima Smooth
Connecting
Flue Pipe
Typical liner installation detail
Construction begins by providing a suitable foundation and
constructional hearth in accordance with Building Regulations
and site requirements.
STOVE IN RECESS OPTION
Our pre stressed lintels can be installed above the fireplace
recess , for this method a support plate is required under the
support block.
Alternatively a suitable cast-in-situ concrete slab lintel can be
created above the fireplace recess. (See our standard drawings
for hole size depending on diameter of chosen flue).
The support block is bedded onto
the slab lintel using weak mix mortar.
A stainless steel adaptor is used to
connect from the support block to
the stove flue pipe. This adaptor is
pushed up onto the support block
spigot (fibre rope should be used to
create a seal). It is recommended to
have a minimum of 600mm length
of flue pipe before connecting to the
chimney.
STOVE IN RECESS OPTION
Support block for
stove connection
Support plate
7N blockwork
140 x 140mm lintels
100 x 65mm lintels
Prima Smooth
connecting flue pipe
ALL OPTIONS
Apply Schiedel Rapid Cement onto the male rebate of the flue
liner.
Position the flue liner on a suitably formed fire gather or support
block with the female rebate facing upwards. Arrows on each
flue liner indicate the directional flow of flue gases. Continue to
apply high temperature cement to each flue liner, cleaning any
access material from the joints.
Joints sealed with Rapid
Light Expanded
Clay Aggregate
insulation
Joints sealed with
Schiedel Rapid HT Cement
Clad the flue liners with a minimum of 100mm suitable masonry.
A minimum of 15mm light expanded clay aggregate must be
installed between the flue liners and masonry. Mix 20 parts
light expanded clay aggregate to 1 Part cement and a small
amount of water. Ensure it is well mixed before using. (refer to
table on page 3)
FREE STANDING STOVE OPTION
A soot door must be provided below the flue pipe entry
to allow for inspection and removal of soot and debris. A
suitable wall sleeve is to be used to seal the cavity wall. Any
combustible insulation within the wall must be kept away
from the single skin connecting flue pipe by at least 1.5 x its
diameter.
(Example: diameter 150mm x 1.5 = 225mm distance).
The flue pipe is a push fit over the spigot on the adaptor. Seal
off the gap between the flue pipe and wall sleeve with fire proof
rope and closing plate.
7
STOVE IN RECESS OPTION
Installation detail
Light expanded clay aggregate
Round Liner
STOVE IN RECESS OPTION
Support block for
stove connection
Support plate
7N blockwork
140 x 140mm lintels
100 x 65mm lintels
Prima Smooth
Gather Lintel
You must provide adequate clearance from combustible material
in accordance with local Building Regulations. Combustible
materials must be 200mm from the inner surface of flue liner or
40mm from the outside of the masonry chimney unless it is a
floorboard, skirting board, dado or picture rail, mantel-shelf or
architrave.
Fit appropriate lead dpc’s and flashings in accordance with the
relevant regulations. It is recommend that the lead tray should
be dressed up the outside of the flue liners to avoid a weak joint.
Weep holes should be provided above the tray for moisture
drainage.
Terminate the chimney to the correct height in accordance
with local Building Regulations. The chimney can be finished by
flaunching (1:3 cement/sharp sand) around a suitable chimney
pot. Approved rain caps can be used to help prevent water
entering the flue.
Flaunching
Weep holes
above tray
Tray and
flashing
Liner or
chimney pot
If Bends are required in the chimney make sure adequate
support is provided and always backfill with light expanded
clay aggregate insulation mix. Liners can be cut between bends
to achieve a required offset distance. A steel collar as well as
high temperature cement must be used for any cut joints. A
maximum of 2 complete offsets (4 bends) are allowed per
chimney and the angle must not be greater than 45˚ from the
vertical.
AFTER COMPLETION
After installation is complete tests and checks should be carried
out in accordance with local Building Regulations. A chimney
notice plate must be completed and permanently fixed in the
dwelling, ideally near the electrical consumer unit. The checklist
and notice plate are available from Schiedel.
USE AND MAINTENANCE
The chimney should be swept at least twice a year, once before
the heating season and once after the heating season. You may
need to sweep during the heating season depending upon use.
Schiedel do not recommend the use of power sweeping brushes
as they can cause damage to the flue.
Always follow the appliance manufacturer’s operating
instructions. Always burn approved fuels or dry seasoned wood.
Avoid burning unseasoned wood and slow burning of solid fuels
as this can produce excessive soot and condensation which
can in turn cause soot fires and damage. If correctly installed,
operated and maintained these systems should last the life of
the dwelling.
SUPPORTING AN OFFSET
The bends and liners
that make up an offset
must be supported
adequately Steel collar
around cut joint
8
Int Ø mm Ext Ø mm Chimney void
(mm)
Chimney void
(inches)
Bags (per linear
metre)
160 190 235 x 235 9” x 9” 0.48
160 190 235 x 350 9” x 14” 1.02
160 190 350 x 350 14” x 14” 1.82
180 210 235 x 235 9” x 9” 1.08
180 210 235 x 350 9” x 14” 1.62
180 210 350 x 350 14” x 14” 2.42
200 230 350 x 350 14” x 14” 2.15
200 230 350 x 460 14” x 18” 2.49
200 230 460 x 460 18” x 18” 4.20
Usage of ceramic sealant
& light expanded clay aggregate
LIGHT EXPANDED CLAY AGGREGATE INSULATION
REQUIREMENT FOR BACKFILL
RAPID HT CEMENT USAGE
Int Ø mm No. joints per tube
160 9
180 7
200 6
9
Diameter (mm) Bends 30o
Length 330 mm Total height Total offset
160 2 0 612 164
160 2 1 899 330
180 2 0 612 164
180 2 1 899 330
200 2 0 612 164
200 2 1 899 330
Diameter (mm) Bends 15o
Length 330 mm Total height Total offset
160 2 0 639 84
160 2 1 956 169
180 2 0 639 84
180 2 1 956 169
200 2 0 639 84
200 2 1 956 169
Diameter (mm) Bends 37.5o
Length 330 mm Total height Total offset
160 2 0 588 200
160 2 1 851 402
180 2 0 588 200
180 2 1 851 402
200 2 0 588 200
200 2 1 851 402
Diameter (mm) Bends 45o
Length 330 mm Total height Total offset
160 2 0 559 232
160 2 1 794 466
180 2 0 559 232
180 2 1 794 466
200 2 0 559 232
200 2 1 794 466
Offsets
OFFSET WITH
2 BENDS
Total Offset
Vertical
Height
The bends and liners that make
up an offset must be supported
adequately
OFFSET WITH
2 BENDS & LINER
Total Offset
Vertical
Height
SUPPORTING
AN OFFSET
Steel collar
around cut joint
Roll top
chimney pot
Square support block
and support plate
Stainless
steel adaptor
Liners
Light expanded clay
aggregate insulation
Ready made ceramic flue
packages for housebuilders
11
CODE PRODUCT QTY
126373 150mm diameter stainless steel adaptor 1
127694 340mm square support plate (210mm i/d) 1
126366 150mm i/d 310mm square support block 1
100374 160mm i/d 330mm high ceramic liner 22
100020 Rapid high temp sealant 310ml tube 3
130769 50ltr bag of light expanded insulation 13
127714 225mm i/d x 450mm terracotta high roll top pot 1
130737 Terracotta with steel topguard 1
130696 Chimney notice plate 1
Installation detail
Ceramic chimney package designed for a two storey installation
„ We can devise ready made packages with all components included for any house styles.
„ This is a very cost effective way of building a chimney, due to our rapid turnaround and delivery
options on site.
Schiedel Chimney Systems Ltd.
Unit 8 & 9, Block A, Holton Road
Holton Heath Industrial Estate
Poole, Dorset BH16 6LG
Tel. +44 (0)1202 861650
sales.uk@schiedel.com
www.schiedel.com/uk
Follow us on Social Media @SchiedelUK
SCHIEDEL INSTALLER REWARDS
Exciting news from Schiedel Chimney Systems!
Whenever you register an installation with our
easy to use, online guarantee registration portal,
you will now accrue points based on the number
of installations and installation type to redeem for
Love2Shop vouchers!
Schiedel ePURO is the fine dust filter for wood burning
appliances. It's electrostatic fine dust separator effectively
reduces flue gas particles up to 95%.

Weitere ähnliche Inhalte

Ähnlich wie Ceramic Liners brochure

Mill 14-1-15 - Sheet - A111 - PROPOSED PLAN DETAILS
Mill 14-1-15 - Sheet - A111 - PROPOSED PLAN DETAILSMill 14-1-15 - Sheet - A111 - PROPOSED PLAN DETAILS
Mill 14-1-15 - Sheet - A111 - PROPOSED PLAN DETAILS
Sin Byrne
 
Freelance project management residential
Freelance project management residentialFreelance project management residential
Freelance project management residential
grahamelanders
 
Freelance project management residential
Freelance project management residentialFreelance project management residential
Freelance project management residential
grahamelanders
 
Freelance project management case studies - residential
Freelance project management case studies - residentialFreelance project management case studies - residential
Freelance project management case studies - residential
grahamelanders
 
Leisure Centre
Leisure CentreLeisure Centre
Leisure Centre
Edel Fox
 
Case study for slough police station
Case study for slough police stationCase study for slough police station
Case study for slough police station
Andy Brown
 
011 - Proposed Ground Floor plan
011 - Proposed Ground Floor plan011 - Proposed Ground Floor plan
011 - Proposed Ground Floor plan
Danny Chiverton
 
CalCast Brochure-EN
CalCast Brochure-ENCalCast Brochure-EN
CalCast Brochure-EN
Guido Heuts
 
PLASTECH 2015 BROCHURE
PLASTECH 2015 BROCHUREPLASTECH 2015 BROCHURE
PLASTECH 2015 BROCHURE
Lee Fifield
 
House Odendahl (SITE PLAN)-A1
House Odendahl (SITE PLAN)-A1House Odendahl (SITE PLAN)-A1
House Odendahl (SITE PLAN)-A1
David Dinsdale
 

Ähnlich wie Ceramic Liners brochure (19)

7545 102 final elevations as proposed
7545 102 final elevations as proposed7545 102 final elevations as proposed
7545 102 final elevations as proposed
 
S-LINE Accoustic Pipes Suppliers in Sharjah,UAE
S-LINE Accoustic Pipes Suppliers in Sharjah,UAES-LINE Accoustic Pipes Suppliers in Sharjah,UAE
S-LINE Accoustic Pipes Suppliers in Sharjah,UAE
 
Mill 14-1-15 - Sheet - A111 - PROPOSED PLAN DETAILS
Mill 14-1-15 - Sheet - A111 - PROPOSED PLAN DETAILSMill 14-1-15 - Sheet - A111 - PROPOSED PLAN DETAILS
Mill 14-1-15 - Sheet - A111 - PROPOSED PLAN DETAILS
 
Freelance project management residential
Freelance project management residentialFreelance project management residential
Freelance project management residential
 
Freelance project management residential
Freelance project management residentialFreelance project management residential
Freelance project management residential
 
Freelance project management case studies - residential
Freelance project management case studies - residentialFreelance project management case studies - residential
Freelance project management case studies - residential
 
Prima Plus flue system installation instructions
Prima Plus flue system installation instructionsPrima Plus flue system installation instructions
Prima Plus flue system installation instructions
 
Leisure Centre
Leisure CentreLeisure Centre
Leisure Centre
 
Plastech Titan
Plastech TitanPlastech Titan
Plastech Titan
 
Ultra Universal Pipe Wrap & Universal Pipe Sleeve Brochure
Ultra Universal Pipe Wrap & Universal Pipe Sleeve BrochureUltra Universal Pipe Wrap & Universal Pipe Sleeve Brochure
Ultra Universal Pipe Wrap & Universal Pipe Sleeve Brochure
 
Contura 35L
Contura 35LContura 35L
Contura 35L
 
UK Plus Brochure
UK Plus Brochure UK Plus Brochure
UK Plus Brochure
 
Case study for slough police station
Case study for slough police stationCase study for slough police station
Case study for slough police station
 
011 - Proposed Ground Floor plan
011 - Proposed Ground Floor plan011 - Proposed Ground Floor plan
011 - Proposed Ground Floor plan
 
CalCast Brochure-EN
CalCast Brochure-ENCalCast Brochure-EN
CalCast Brochure-EN
 
989 895-20
989 895-20989 895-20
989 895-20
 
PLASTECH 2015 BROCHURE
PLASTECH 2015 BROCHUREPLASTECH 2015 BROCHURE
PLASTECH 2015 BROCHURE
 
Prima Smooth flue system installation instructions
Prima Smooth flue system installation instructionsPrima Smooth flue system installation instructions
Prima Smooth flue system installation instructions
 
House Odendahl (SITE PLAN)-A1
House Odendahl (SITE PLAN)-A1House Odendahl (SITE PLAN)-A1
House Odendahl (SITE PLAN)-A1
 

Mehr von Schiedel UK

Mehr von Schiedel UK (20)

Instructions Garden Fireplace
Instructions Garden FireplaceInstructions Garden Fireplace
Instructions Garden Fireplace
 
ICS 5000 commercial flue system instructions
ICS 5000 commercial flue system instructionsICS 5000 commercial flue system instructions
ICS 5000 commercial flue system instructions
 
Sargas Stove System Brochure
Sargas Stove System Brochure Sargas Stove System Brochure
Sargas Stove System Brochure
 
Prima Smooth Brochure
Prima Smooth Brochure Prima Smooth Brochure
Prima Smooth Brochure
 
ICID flue system installation instructions
ICID flue system installation instructionsICID flue system installation instructions
ICID flue system installation instructions
 
Protect Box instructions
Protect Box instructionsProtect Box instructions
Protect Box instructions
 
Instructions Garden Fireplace 500
Instructions Garden Fireplace 500Instructions Garden Fireplace 500
Instructions Garden Fireplace 500
 
Instructions Garden Fireplace 950
Instructions Garden Fireplace 950Instructions Garden Fireplace 950
Instructions Garden Fireplace 950
 
Instructions for installation and operation Sargas 1 and Sargas 3
Instructions for installation and operation Sargas 1 and Sargas 3Instructions for installation and operation Sargas 1 and Sargas 3
Instructions for installation and operation Sargas 1 and Sargas 3
 
Schiedel Metaloterm UE flue system
Schiedel Metaloterm UE flue systemSchiedel Metaloterm UE flue system
Schiedel Metaloterm UE flue system
 
Schiedel Commercial Brochure
Schiedel Commercial BrochureSchiedel Commercial Brochure
Schiedel Commercial Brochure
 
Schiedel Metaloterm ME flue system
Schiedel Metaloterm ME flue systemSchiedel Metaloterm ME flue system
Schiedel Metaloterm ME flue system
 
Schiedel Metaloterm MFflue system
Schiedel Metaloterm MFflue systemSchiedel Metaloterm MFflue system
Schiedel Metaloterm MFflue system
 
ICS 5000 UK version
ICS 5000 UK version ICS 5000 UK version
ICS 5000 UK version
 
Sirius stove system operating manual
Sirius stove system operating manualSirius stove system operating manual
Sirius stove system operating manual
 
Celsius volcanic pumice frame stove operating manual
Celsius volcanic pumice frame stove operating manualCelsius volcanic pumice frame stove operating manual
Celsius volcanic pumice frame stove operating manual
 
ICS flue system installation instructions
ICS flue system installation instructionsICS flue system installation instructions
ICS flue system installation instructions
 
Celsius Stove System Brochure
Celsius Stove System Brochure Celsius Stove System Brochure
Celsius Stove System Brochure
 
Flexible Liners installation instructions
Flexible Liners installation instructionsFlexible Liners installation instructions
Flexible Liners installation instructions
 
Sirius Stove System Brochure
Sirius Stove System Brochure Sirius Stove System Brochure
Sirius Stove System Brochure
 

Kürzlich hochgeladen

Environmental Science - Nuclear Hazards and Us.pptx
Environmental Science - Nuclear Hazards and Us.pptxEnvironmental Science - Nuclear Hazards and Us.pptx
Environmental Science - Nuclear Hazards and Us.pptx
hossanmdjobayer103
 
Call Now ☎ Russian Call Girls Connaught Place @ 9899900591 # Russian Escorts ...
Call Now ☎ Russian Call Girls Connaught Place @ 9899900591 # Russian Escorts ...Call Now ☎ Russian Call Girls Connaught Place @ 9899900591 # Russian Escorts ...
Call Now ☎ Russian Call Girls Connaught Place @ 9899900591 # Russian Escorts ...
kauryashika82
 

Kürzlich hochgeladen (20)

Call Girls Jejuri Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Jejuri Call Me 7737669865 Budget Friendly No Advance BookingCall Girls Jejuri Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Jejuri Call Me 7737669865 Budget Friendly No Advance Booking
 
Environmental Science - Nuclear Hazards and Us.pptx
Environmental Science - Nuclear Hazards and Us.pptxEnvironmental Science - Nuclear Hazards and Us.pptx
Environmental Science - Nuclear Hazards and Us.pptx
 
(NEHA) Call Girls Navi Mumbai Call Now 8250077686 Navi Mumbai Escorts 24x7
(NEHA) Call Girls Navi Mumbai Call Now 8250077686 Navi Mumbai Escorts 24x7(NEHA) Call Girls Navi Mumbai Call Now 8250077686 Navi Mumbai Escorts 24x7
(NEHA) Call Girls Navi Mumbai Call Now 8250077686 Navi Mumbai Escorts 24x7
 
Call Girls Moshi Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Moshi Call Me 7737669865 Budget Friendly No Advance BookingCall Girls Moshi Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Moshi Call Me 7737669865 Budget Friendly No Advance Booking
 
Verified Trusted Kalyani Nagar Call Girls 8005736733 𝐈𝐍𝐃𝐄𝐏𝐄𝐍𝐃𝐄𝐍𝐓 Call 𝐆𝐈𝐑𝐋 𝐕...
Verified Trusted Kalyani Nagar Call Girls  8005736733 𝐈𝐍𝐃𝐄𝐏𝐄𝐍𝐃𝐄𝐍𝐓 Call 𝐆𝐈𝐑𝐋 𝐕...Verified Trusted Kalyani Nagar Call Girls  8005736733 𝐈𝐍𝐃𝐄𝐏𝐄𝐍𝐃𝐄𝐍𝐓 Call 𝐆𝐈𝐑𝐋 𝐕...
Verified Trusted Kalyani Nagar Call Girls 8005736733 𝐈𝐍𝐃𝐄𝐏𝐄𝐍𝐃𝐄𝐍𝐓 Call 𝐆𝐈𝐑𝐋 𝐕...
 
Presentation: Farmer-led climate adaptation - Project launch and overview by ...
Presentation: Farmer-led climate adaptation - Project launch and overview by ...Presentation: Farmer-led climate adaptation - Project launch and overview by ...
Presentation: Farmer-led climate adaptation - Project launch and overview by ...
 
Call Girls Pune Airport Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Pune Airport Call Me 7737669865 Budget Friendly No Advance BookingCall Girls Pune Airport Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Pune Airport Call Me 7737669865 Budget Friendly No Advance Booking
 
Enhancing forest data transparency for climate action
Enhancing forest data transparency for climate actionEnhancing forest data transparency for climate action
Enhancing forest data transparency for climate action
 
VVIP Pune Call Girls Wagholi WhatSapp Number 8005736733 With Elite Staff And ...
VVIP Pune Call Girls Wagholi WhatSapp Number 8005736733 With Elite Staff And ...VVIP Pune Call Girls Wagholi WhatSapp Number 8005736733 With Elite Staff And ...
VVIP Pune Call Girls Wagholi WhatSapp Number 8005736733 With Elite Staff And ...
 
RATING SYSTEMS- IGBC, GRIHA, LEED--.pptx
RATING  SYSTEMS- IGBC, GRIHA, LEED--.pptxRATING  SYSTEMS- IGBC, GRIHA, LEED--.pptx
RATING SYSTEMS- IGBC, GRIHA, LEED--.pptx
 
VIP Model Call Girls Wagholi ( Pune ) Call ON 8005736733 Starting From 5K to ...
VIP Model Call Girls Wagholi ( Pune ) Call ON 8005736733 Starting From 5K to ...VIP Model Call Girls Wagholi ( Pune ) Call ON 8005736733 Starting From 5K to ...
VIP Model Call Girls Wagholi ( Pune ) Call ON 8005736733 Starting From 5K to ...
 
Deforestation
DeforestationDeforestation
Deforestation
 
Call Now ☎ Russian Call Girls Connaught Place @ 9899900591 # Russian Escorts ...
Call Now ☎ Russian Call Girls Connaught Place @ 9899900591 # Russian Escorts ...Call Now ☎ Russian Call Girls Connaught Place @ 9899900591 # Russian Escorts ...
Call Now ☎ Russian Call Girls Connaught Place @ 9899900591 # Russian Escorts ...
 
Call Girls Service Pune ₹7.5k Pick Up & Drop With Cash Payment 8005736733 Cal...
Call Girls Service Pune ₹7.5k Pick Up & Drop With Cash Payment 8005736733 Cal...Call Girls Service Pune ₹7.5k Pick Up & Drop With Cash Payment 8005736733 Cal...
Call Girls Service Pune ₹7.5k Pick Up & Drop With Cash Payment 8005736733 Cal...
 
VVIP Pune Call Girls Vishal Nagar WhatSapp Number 8005736733 With Elite Staff...
VVIP Pune Call Girls Vishal Nagar WhatSapp Number 8005736733 With Elite Staff...VVIP Pune Call Girls Vishal Nagar WhatSapp Number 8005736733 With Elite Staff...
VVIP Pune Call Girls Vishal Nagar WhatSapp Number 8005736733 With Elite Staff...
 
RA 7942:vThe Philippine Mining Act of 1995
RA 7942:vThe Philippine Mining Act of 1995RA 7942:vThe Philippine Mining Act of 1995
RA 7942:vThe Philippine Mining Act of 1995
 
DENR EPR Law Compliance Updates April 2024
DENR EPR Law Compliance Updates April 2024DENR EPR Law Compliance Updates April 2024
DENR EPR Law Compliance Updates April 2024
 
CSR_Tested activities in the classroom -EN
CSR_Tested activities in the classroom -ENCSR_Tested activities in the classroom -EN
CSR_Tested activities in the classroom -EN
 
Presentation: Farmer-led climate adaptation - Project launch and overview by ...
Presentation: Farmer-led climate adaptation - Project launch and overview by ...Presentation: Farmer-led climate adaptation - Project launch and overview by ...
Presentation: Farmer-led climate adaptation - Project launch and overview by ...
 
Climate Change
Climate ChangeClimate Change
Climate Change
 

Ceramic Liners brochure

  • 1. www.schiedel.com/uk Ceramic Chimney Liners SAP 940003679 - September 2022 The cost effective way for housebuilders to add a safe chimney to their developments and reduce gas bills SECONDARY HEATING
  • 2. 2 Resistant to temperature change The liners are extremely durable and have been tested for resistance to soot fire as well as to condensate, and meet the latest CE standards and Construction Product Regulation (CPR). Cost effective and reduces gas heating bills Ideal for homes where you require a cost effective, safe and easy to construct system. Usage of a log burning stove reduces the need to heat homes with radiators, therefore less reliance on increasing gas heating bills. Lightweight Due to advanced manufacturing techniques, we have been able to reduce the wall thickness of the liner to produce the optimal lightweight but extremely robust product which is natural and environmentally friendly. Other great features of using ceramic liners: „ Suitable for all fuels – gas, oil, solid fuels and biomass fuels. „ Wide range of accessories to suit numerous installations. „ Suitable for high temperature and low temperature applications. „ Full compliance to the latest CE standards and Construction Products Regulations (CPR). Using correctly sized liners for new chimneys „ Flexible flue liners should be used only to RELINE a chimney and should not be used in a new chimney, which means that ceramic is a cost effective and legal solution. Ceramic Flue Liners CERAMIC LINERS CHOOSING THE CORRECT LINER SIZE FOR NEW CHIMNEYS. 225mm concrete liner Costly and avoidable steel liner Correctly sized ceramic liner “New masonry chimneys should be constructed with flue liners suitable for the intended application”.
  • 3. 3 Approvals Rapid Joint detail „ Liners are installed with the male spigot pointing downwards. „ Sealant should be applied to the inside of the socket uppermost and any excess projecting into the flue should be wiped off as installation progresses. Rapid Direction of flue gases Schiedel Ceramic Liners are CE Certified to EN 1457-1 & 2 TÜV 0780 CPD 131086 with the following designations: * When used on T200 rated low temperature systems, the liner system should be straight and fully ventilated. High Temperature Applications Low Temperature Applications EN 1457-1 A1 N1 (T600 N1 G) EN 1457-2 B4 N1 (T400 N1 WC O) D4 N1 (T200 N1 WC O)* Ceramic Flue Liners Chimney pots Schiedel Chimney Systems provide a high performance chimney pot to finish any building. Available in Buff or Terracotta – a chimney pot can add a decorative charm and appeal to an otherwise ordinary chimney stack. Manufactured in accordance with BS EN 13502 : 2002. Apply Schiedel Rapid Cement into the socket of the flue liner as shown.
  • 4. 4 Liners A 30˚ B A 37.5˚ B A 45˚ B A A C B A B A C B A C B 130 A Liner Int Ømm 160 180 200 Ext Ø 190 210 230 A 330 330 330 Weight 5.8 6.3 7.1 Pallet Qty 125 100 75 SAP Code 100374 100375 100376 30˚ Bend Int Ømm 160 180 200 Ext Ø 190 210 230 A 189 192 194 B 189 192 194 Weight 5.8 6.3 7.1 SAP Code 131625 131626 131627 15˚ Bend Int Ømm 160 180 200 Ext Ø 190 - 230 A 178.6 - 178.6 B 178.6 - 178.6 Weight - 6.91 SAP Code 131856 - 133899 45˚ Bend Int Ømm 160 180 200 Ext Ø 190 - 230 A 203 - 211 B 203 - 211 Weight 5.8 - 7.1 SAP Code 131622 - 131624 37.5˚ Bend Int Ømm 160 180 200 Ext Ø 190 210 230 A 194 199 202 B 196 199 202 Weight 5.8 6.3 7.1 SAP Code 121334 121335 121336 Outer Soot Door Int Ømm 160 180 200 Ext Ø 190 210 230 A 400 400 400 B 250 250 250 SAP Code 100475 100475 100475 Inspection Pipe with Inner Soot Door Int Ømm 160 180 200 Ext Ø 190 210 230 A 660 660 660 B 165 165 165 C 295 295 295 Weight 14 15 17 SAP Code 100428 100429 100430 90˚ Tee Liner Int Ømm 160 180 200 Ext Ø 190 210 230 A 660 660 660 B 331 331 331 C 175 190 195 Weight 14 15 16 SAP Code 100420 100421 100422 135˚ Tee Liner Int Ømm 160 180 200 Ext Ø 190 210 230 A 660 660 660 B 463 481 497 C 311 326 357 Weight 16 18 19 SAP Code 100424 100425 100426 Steel collars (for cut joints) Int Ømm 160 180 200 SAP Code 158122 - 158123 Adaptor from Steel to Ceramic T Liner Int Ømm 160 180 200 Ext Ø 190 210 230 Ø Steel (A) 150 175 200 SAP Code 132667 132668 132669 B A 15˚
  • 5. 5 130 A 130 A Components Lintels are used in pairs to support the weight of the support block and liners as an alternative to a cast slab. On a clear span of up to 1.2m a load of up to 3250Kg can be supported. Rapid A B A 200 280 A 340 340 ØA 1500 140 140 Adaptor from Steel to Support Block Int Ømm 160 180 200 Ext Ø 190 210 230 Ø Steel (A) 150 175 200 SAP Code 126373 126499 127691 Increasing Adaptor from Steel to Support Block (with rope) Int Ømm 160 180 200 Ext Ø 190 210 230 Ø Steel (A) 125 150 150 SAP Code 126357 126493 127671 Support Blocks Int Ømm 160 180 200 Ext Ø 190 210 230 Weight 7 8 8 SAP Code 126366 126483 127340 Support Plate Int Ømm 160 180 200 Ext Ø 340 360 360 SAP Code 127694 128549 128549 Rapid High Temperature Joint Sealant Size ml 310 SAP Code 100020 Support Lintel Size mm 140x140 Length mm 1500 Weight kg 71 SAP Code 146431 Support Lintel Size mm 100 x 65 Length mm 600 Weight kg 9 SAP Code 169330 Base Stone with Drain Int Ømm 160 180 200 A 170 170 170 B 70 70 70 SAP Code 102984 102685 10686 Light Expanded Clay Aggregate Backfill Insulation (50 litre) Size m3 0.05 Weight kg 19 SAP Code 130769 Topguard (Buff and Terracotta options) Int Ømm 150-250 A 300 SAP Code Buff 130742 SAP Code T'cotta 130737 Chimney Pot (Buff and Terracotta options) Int Ømm 150 200 A 450 450 SAP Code Buff 126370 130697 SAP Code T'cotta 126371 127341 Chimney Notice Plate SAP Code 130696
  • 6. 6 FREE STANDING STOVE OPTION 45˚ Tee liner Wall Sleeve Trim Collar Soot Door Base Stone with Drain Inspection Pipe Tee Liner and Steel Adaptor Prima Smooth Connecting Flue Pipe Typical liner installation detail Construction begins by providing a suitable foundation and constructional hearth in accordance with Building Regulations and site requirements. STOVE IN RECESS OPTION Our pre stressed lintels can be installed above the fireplace recess , for this method a support plate is required under the support block. Alternatively a suitable cast-in-situ concrete slab lintel can be created above the fireplace recess. (See our standard drawings for hole size depending on diameter of chosen flue). The support block is bedded onto the slab lintel using weak mix mortar. A stainless steel adaptor is used to connect from the support block to the stove flue pipe. This adaptor is pushed up onto the support block spigot (fibre rope should be used to create a seal). It is recommended to have a minimum of 600mm length of flue pipe before connecting to the chimney. STOVE IN RECESS OPTION Support block for stove connection Support plate 7N blockwork 140 x 140mm lintels 100 x 65mm lintels Prima Smooth connecting flue pipe ALL OPTIONS Apply Schiedel Rapid Cement onto the male rebate of the flue liner. Position the flue liner on a suitably formed fire gather or support block with the female rebate facing upwards. Arrows on each flue liner indicate the directional flow of flue gases. Continue to apply high temperature cement to each flue liner, cleaning any access material from the joints. Joints sealed with Rapid Light Expanded Clay Aggregate insulation Joints sealed with Schiedel Rapid HT Cement Clad the flue liners with a minimum of 100mm suitable masonry. A minimum of 15mm light expanded clay aggregate must be installed between the flue liners and masonry. Mix 20 parts light expanded clay aggregate to 1 Part cement and a small amount of water. Ensure it is well mixed before using. (refer to table on page 3) FREE STANDING STOVE OPTION A soot door must be provided below the flue pipe entry to allow for inspection and removal of soot and debris. A suitable wall sleeve is to be used to seal the cavity wall. Any combustible insulation within the wall must be kept away from the single skin connecting flue pipe by at least 1.5 x its diameter. (Example: diameter 150mm x 1.5 = 225mm distance). The flue pipe is a push fit over the spigot on the adaptor. Seal off the gap between the flue pipe and wall sleeve with fire proof rope and closing plate.
  • 7. 7 STOVE IN RECESS OPTION Installation detail Light expanded clay aggregate Round Liner STOVE IN RECESS OPTION Support block for stove connection Support plate 7N blockwork 140 x 140mm lintels 100 x 65mm lintels Prima Smooth Gather Lintel You must provide adequate clearance from combustible material in accordance with local Building Regulations. Combustible materials must be 200mm from the inner surface of flue liner or 40mm from the outside of the masonry chimney unless it is a floorboard, skirting board, dado or picture rail, mantel-shelf or architrave. Fit appropriate lead dpc’s and flashings in accordance with the relevant regulations. It is recommend that the lead tray should be dressed up the outside of the flue liners to avoid a weak joint. Weep holes should be provided above the tray for moisture drainage. Terminate the chimney to the correct height in accordance with local Building Regulations. The chimney can be finished by flaunching (1:3 cement/sharp sand) around a suitable chimney pot. Approved rain caps can be used to help prevent water entering the flue. Flaunching Weep holes above tray Tray and flashing Liner or chimney pot If Bends are required in the chimney make sure adequate support is provided and always backfill with light expanded clay aggregate insulation mix. Liners can be cut between bends to achieve a required offset distance. A steel collar as well as high temperature cement must be used for any cut joints. A maximum of 2 complete offsets (4 bends) are allowed per chimney and the angle must not be greater than 45˚ from the vertical. AFTER COMPLETION After installation is complete tests and checks should be carried out in accordance with local Building Regulations. A chimney notice plate must be completed and permanently fixed in the dwelling, ideally near the electrical consumer unit. The checklist and notice plate are available from Schiedel. USE AND MAINTENANCE The chimney should be swept at least twice a year, once before the heating season and once after the heating season. You may need to sweep during the heating season depending upon use. Schiedel do not recommend the use of power sweeping brushes as they can cause damage to the flue. Always follow the appliance manufacturer’s operating instructions. Always burn approved fuels or dry seasoned wood. Avoid burning unseasoned wood and slow burning of solid fuels as this can produce excessive soot and condensation which can in turn cause soot fires and damage. If correctly installed, operated and maintained these systems should last the life of the dwelling. SUPPORTING AN OFFSET The bends and liners that make up an offset must be supported adequately Steel collar around cut joint
  • 8. 8 Int Ø mm Ext Ø mm Chimney void (mm) Chimney void (inches) Bags (per linear metre) 160 190 235 x 235 9” x 9” 0.48 160 190 235 x 350 9” x 14” 1.02 160 190 350 x 350 14” x 14” 1.82 180 210 235 x 235 9” x 9” 1.08 180 210 235 x 350 9” x 14” 1.62 180 210 350 x 350 14” x 14” 2.42 200 230 350 x 350 14” x 14” 2.15 200 230 350 x 460 14” x 18” 2.49 200 230 460 x 460 18” x 18” 4.20 Usage of ceramic sealant & light expanded clay aggregate LIGHT EXPANDED CLAY AGGREGATE INSULATION REQUIREMENT FOR BACKFILL RAPID HT CEMENT USAGE Int Ø mm No. joints per tube 160 9 180 7 200 6
  • 9. 9 Diameter (mm) Bends 30o Length 330 mm Total height Total offset 160 2 0 612 164 160 2 1 899 330 180 2 0 612 164 180 2 1 899 330 200 2 0 612 164 200 2 1 899 330 Diameter (mm) Bends 15o Length 330 mm Total height Total offset 160 2 0 639 84 160 2 1 956 169 180 2 0 639 84 180 2 1 956 169 200 2 0 639 84 200 2 1 956 169 Diameter (mm) Bends 37.5o Length 330 mm Total height Total offset 160 2 0 588 200 160 2 1 851 402 180 2 0 588 200 180 2 1 851 402 200 2 0 588 200 200 2 1 851 402 Diameter (mm) Bends 45o Length 330 mm Total height Total offset 160 2 0 559 232 160 2 1 794 466 180 2 0 559 232 180 2 1 794 466 200 2 0 559 232 200 2 1 794 466 Offsets OFFSET WITH 2 BENDS Total Offset Vertical Height The bends and liners that make up an offset must be supported adequately OFFSET WITH 2 BENDS & LINER Total Offset Vertical Height SUPPORTING AN OFFSET Steel collar around cut joint
  • 10. Roll top chimney pot Square support block and support plate Stainless steel adaptor Liners Light expanded clay aggregate insulation Ready made ceramic flue packages for housebuilders
  • 11. 11 CODE PRODUCT QTY 126373 150mm diameter stainless steel adaptor 1 127694 340mm square support plate (210mm i/d) 1 126366 150mm i/d 310mm square support block 1 100374 160mm i/d 330mm high ceramic liner 22 100020 Rapid high temp sealant 310ml tube 3 130769 50ltr bag of light expanded insulation 13 127714 225mm i/d x 450mm terracotta high roll top pot 1 130737 Terracotta with steel topguard 1 130696 Chimney notice plate 1 Installation detail Ceramic chimney package designed for a two storey installation „ We can devise ready made packages with all components included for any house styles. „ This is a very cost effective way of building a chimney, due to our rapid turnaround and delivery options on site.
  • 12. Schiedel Chimney Systems Ltd. Unit 8 & 9, Block A, Holton Road Holton Heath Industrial Estate Poole, Dorset BH16 6LG Tel. +44 (0)1202 861650 sales.uk@schiedel.com www.schiedel.com/uk Follow us on Social Media @SchiedelUK SCHIEDEL INSTALLER REWARDS Exciting news from Schiedel Chimney Systems! Whenever you register an installation with our easy to use, online guarantee registration portal, you will now accrue points based on the number of installations and installation type to redeem for Love2Shop vouchers! Schiedel ePURO is the fine dust filter for wood burning appliances. It's electrostatic fine dust separator effectively reduces flue gas particles up to 95%.