2. IIACTAtek Access Manager Suite User Manual Version 1.01.1
Contents
Pre-requisites III
I. About the External I/O Board III
Functions III
Point to Take Note of III
Connection Chart III
Installation 1
1.1 Layout of External I/O Board 1
1.2 Installation of External I/O Board with ACTAtek 3 2
Copyright 2010 ACTAtek Pte Limited, All rights reserved.
No part of this document may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language, in any form or by
any means, electronic, mechanical, magnetic, optical, chemical, manual or otherwise without the prior written permission of ACTAtek Pte Limited.
ACTAtek is a registered trademark of ACTAtek Pte Limited.
All trademarks, registered trademarks, and service marks are the property of their respective owners.
3. IIIACTAtek Access Manager Suite User Manual Version 1.01.1
Pre-requisites
I. About the External I/O Board
Functions
⢠ACTAtek provides an optional External I/O Board for additional inputs and outputs to be connected
for various functions.
⢠The External I/O Board is for installation with ACTAtek 3 only.
⢠The External I/O Board will allow the ACTAtek 3 to connect to EM locks Alarms, input door
sensors, and allow Wiegand communications.
⢠The External I/O Board will work in a similar way as the Secure External Relay; as it will control the
door strike once properly installed with an ACTAtek 3 unit.
Point to Take Note of
⢠Once the I/O Board is connected to the ACTAtek 3 unit, both the Door Strike and Door Switch on
ACTA3 will not function due to security reasons.
⢠For Firmware 1195, it is required to Login to ACTAtek 3 web admin page - External Devices - to
click [add] External I/O Board and then go to [terminal setup] to configure Wiegand Output.
Connection Chart
The External I/O Board consists of the following:
Relay Number of
Door Strike 4 (currently only 2 are in use)
Door Switch 2
Door Sense 2
Wiegand Output 1
Wiegand Input 1 (currently not in use)
RS232 1
RS485 N|L
4. 1ACTAtek External I/O Board Installation Manual Version 1.2
1.1 Layout of External I/O Board
Installation
⢠Door Strike 1 = For connection to EM Lock
⢠Door Strike 2 = For other usage i.e. External Buzzer
⢠Door Senses = Sensor for detecting of door being left open
⢠Door Switches = Door Strike will be activated once Door Switch is a closed circuit.
⢠Power Supply = For connection to DV 12V Power Supply
⢠DC Out = To power up ACTAtek 3 unit (optional)
⢠RS232 = For connection to ACTAtek 3 unit
⢠Wiegand Out = For Wiegand Output (26bit) interface
5. 2ACTAtek External I/O Board Installation Manual Version 1.2
1.2 Installation of External I/O Board with ACTAtek 3
1. Connect the RS232 cable provided to the RS232 (JP 17) on ACTAtek 3 unit.
2. Connect Power Cables to JP13 of External I/O Board as per diagram.
3. Power up External I/O Board (wait for 2 seconds or wait for amber led reamin âONâ
only before continuing to step 4.
4. Power up ACTAtek 3 (Test out remote door open function or Access with pre-en-
rolled user, will activate External I/O Board Door Strike 1)
(Note: you need to connect a door strike EM to the Door Strike I/O board in order to verify)