Boost Fertility New Invention Ups Success Rates.pdf
Final presentation for the final project ahmad alqahtani
1. Carbon Footprint of Euro
Village Compound
Ahmad Alqahtani
Prof. Goode
E-16
May 2012
2. Agenda
Description of Euro Village (EV)
Sources of Emissions
Methodology
GHG emissions
GHG reduction plans
Improving the inventory
2
3. Description EV
A fully serviced residential/office complex located
in Khobar, Saudi Arabia
Built in 1975, multiple expansion 80s, 90s, 00s.
Purchases electricity from the Saudi Electricity
Company
Desalinates water onsite using RO
Consists of:
470 villas one school
6 office buildings one nursery
2 hotels one gym
3 workshops 5 kitchens (dining halls)
3
4. Description EV
80’s villa 90’s villa
EuroInn (built in 2005) Office building
4
6. Sources
Sources of emissions
Scope Type of source GHG emissions Sources
1 Stationary Combustion CO2, CH4, N2O Kitchens uses LPG for
cooking
Mobile Combustion CO2, CH4, N2O Trucks, pickups, buses
and cars
Fugitive Emissions HCFC-22 CFC-11 Refrigerators and ACs
2 Purchased Electricity CO2, CH4, N2O SEC power plant
3 Employee Travel CO2, CH4, N2O International Flights
6
7. Methodology
Approach
Operational control - full control over the
operational policies.
All facilities are run and managed by EV
All offices and 4 out of 5 kitchens are leased
EV responsible for all bills and maintenance
One exception is LPG for leased kitchens
7
8. Methodology
Data collection
Scope 1
LPG bills
Freon gas usage records
Diesel and gasoline annual consumption
Distance traveled was estimated
Scope 2
Over 6000 Electric bills.
Scope 3
Vacation schedule
8
9. Methodology
The GRP methods
Scope 1
Stationary Combustion
Tier C method
Emission factors for fuel type (natural gas) and commercial
end user to calculate CH4 and N2O emission factors
Mobile Combustion
Tier B for CO2 emissions and tier C for CH4 and N2O
Distance traveled estimated.
Fugitive Emissions
Tier A method
GWP cited from California Environmental Protection Agency.
9
10. Methodology
Continue the GRP methods
Scope 2
Electricity
Tier B Method.
Emission factors were cited from EIA
Scope 3
Employee Travel
Calculated using carbonfootprint.com
10
11. GHG Emissions
Total emissions
The total emissions released by EV in 2011 was 53,767
metric ton of CO2 equivalent
Purchased electricity + fugitive emissions = over 99%
Scope Emission category Emissions (mtCO2e) % of total emissions
Stationary Combustion 23 0.04%
1Mobile Combustion 236 0.44%
Fugitive Emissions 6,156 11.45%
2Purchased Electricity 47,272 87.92%
3Employee Travel 80 0.15%
Total 53,767 100.00%
11
12. GHG Emissions
Scope 1
LPG
Released about 23 mtCO2e in 2011
Only one kitchen
12
13. GHG Emissions
Scope 1
Mobile Combustion
236 mtCO2e representing less than 0.5%.
13
14. GHG Emissions
Scope 1
Fugitive Emissions
Thetotal emissions topped 6,000 mtCO2e
More than 11% of the total emissions
Mass Consumed Global Warming Potential
(Kg) (mtCO2e)
150 570
4% 9%
HCFC-22
CFC-11
3,724 5585
96% 91%
14
15. GHG Emissions
Scope 2
Electricity consumption released more than 47,000
mtCO2e
kWh Electricity consumption 2011
7,000,000
6,000,000
5,000,000 *Electricity consumption
increases roughly by 70% in the
summer due to AC usage.
4,000,000
3,000,000
2,000,000
1,000,000
0
Jan-11 Feb-11 Mar-11 Apr-11 May-11 Jun-11 Jul-11 Aug-11 Sep-11 Oct-11 Nov-11 Dec-11
Electricity Consumption Average summer Average winter
15
16. GHG Emissions
Scope 3
Employee Travel- only calculated scope 3 emissions
Caluculated through carbonfootprint.com
Radiative Force not factored in.
# of emps. Destinations (main airport) Total (mtCO2e)
47 Kathmandu, Nepal 33.21
35 Calicut, India 22.73
16 Manila, the Philippines’ 21.15
3 Islamabad, Pakistan 1.43
4 Cairo, Egypt 1.48
105 80 mtCO2e
Table 3 shows the number of employees who traveled in 2011.
Carbon Footprint Ltd. Carbon Footprint Calculator. 22 April 2012 <http://www.carbonfootprint.com/calculator.aspx>.
16
17. Reduction
Tracking and Accounting
Tracking
Install a meter at every unit
link bills to the consuming unit
Accounting
Record monthly consumption per unit
Monitor and identify most energy intensive
17
18. Reduction
Energy Audit
Blower Door Test
Air tightness test
Thermographic Scan
Heat loss measurement
Record wattage from labels of all appliances
18
19. Reduction
Energy Efficiency
Construction
Invest in thermal envelope (wall, roof, air/vapor retarders
Intensify weather-stripping and sealing
Low U-factor windows can save up to 25%
19
20. Reduction
…Energy Efficiency
Air Conditioning
Roughly 26% of total electricity consumption
Replace ACs older than 20 years with high SEER to save at
least 20% of cooling costs
Include filter cleaning or replacement to improve the
efficiency by 5%
20
21. Reduction
…Energy Efficiency
Energy Star Appliances
Thousands of electrical appliances, at least 13 per a unit.
Energystar.gov
Look at labels for the most efficient
21
22. Reduction
Replacement of HCFC-22 & CFC-11
HCFC-22
Replace with R-134a
CFC-11
Replace with HFC-123
22
23. Suggested Target
Suggested target
20% reduction by 2020
Will result in reduction of over 10,000 mtCO2e
Quick wins
ACs filter maintenance = 1%
Replacing CFC-11 = 1%
Replacing HCFC-22 = 1%
8 year investment plan
More efficient ACs = 7% reduction
Improved construction = 5% reduction
More efficient appliances = 5%
23
24. Quality Management
Updating the inventory
Updated emission factors
Carbon content of diesel and gasoline
Quality Improvement
Inventory of 2012?
Improving documentation
Records of daily distance traveled
24
26. References
Bhaskaran, Anup. Manager Accounts. Ahmad Alqahtani. 14 April 2012.
Carbon Footprint Ltd. Carbon Footprint Calculator. 22 April 2012
<http://www.carbonfootprint.com/calculator.aspx>.
Emissions Factors & Policy Applications Center. "Emissions Factors & AP 42, Compilation of Air Pollutant Emission
Factors." July 2008. US Environmental Protection Department.
Emmanuel, Gerard. Maintenance engineer Ahmad Alqahtani. 03 03 2012.
Gina McCarthy et al. "General Reporting Protocol." May 2008. The Climate Registry. 4 March 2012.
Lahn, Glada and Paul Stevens. "Burning Oil to Keep Cool: The Hidden Energy Crisis in Saudi Arabia." December
2011. Chatham House. 30 April 2012
<http://www.chathamhouse.org/sites/default/files/public/Research/Energy,%20Environment%20and%20Develo
pment/1211pr_lahn_stevens.pdf>.
MacHarg, John , Thomas F Seacord and Bradley Sessions. ADC baseline tests reveal trends. 20 November 200. 7
April 2012 <http://www.affordabledesal.com/home/DWR%20SWRO%20Profile%20Aug-Sept-08%20article.pdf>.
National Gas and Industrial Company. Gas History. 2008. 06 April 2012
<http://www.gasco.com.sa/index.asp?id=79>.
Office of Air and Radiation. Environmental Protection Agency. "Climate Leaders Greenhouse Gas Inventory
Protocol Core Module Guidance: Direct HFC and PFC emissions from use of refrigeration and air conditioning
equipment." May 2008. United States Environmental Protection Department. 5 3 2012
<http://www.epa.gov/climateleadership/documents/resources/mfgrfg.pdf>.
Office of Energy Efficiency and Renewable Energy, US Department of Energy. Central Air Conditioners. 02
September 2011. 5 April 2012
<http://www.energysavers.gov/your_home/space_heating_cooling/index.cfm/mytopic=12440>.
Refrigerant Management Program Staff. Refrigerant Management Program. 2012. 26 April 2012
<http://www.arb.ca.gov/cc/reftrack/reftrackrefrigerants.htm>.
SG/Reuters. Saudi Arabia to implement new power tariff. 6 June 2010. 30 April 2012
<http://www.saudigazette.com.sa/index.cfm?method=home.regcon&contentID=2010060674522>.
US Department of Energy. Elements of an Energy-Efficient House. July 2000. 29 March 2012
<http://www.nrel.gov/docs/fy00osti/27835.pdf>.
Voluntary Reporting of Greenhouse Gases Program. "Voluntary Reporting of Greenhouse Gases." Energy
Information Adminstration. US Department of Energy. 19 April 2012
<http://www.eia.gov/oiaf/1605/pdf/Appendix%20F_r071023.pdf>.
26
Hinweis der Redaktion
Hell0o0o0 everyone…. This is Ahmad Alqahtani narrating the presentation of the project, which I gave the name Carbon Footprint of Euro Village Compound.I selected the Euro Village Compound to be my project because I knew I will cover all three scopes of the Greenhouse Gas emissions, which made it really interesting and challenging. ……Let’s talk about the agenda for this presentation.
I will start my presentation with an overview of the compound and the facilities I found there. An then I will talk about the scopes of the emissions followed by the methodology used. By methodlogy, I mean the approach, data collection, GRP tier methods, and also the emission factors I adopted.After that I am going to show the calculation results of the total emissions for Carbon Dioxide, Nitrous Oxide, Methane and HFCs. I will explain how the compound can reduce these emissions in a realistic and feasible way. Afterwards I will point out some of the risks of not reducing the emissions and opportunities in making Euro Village more sustainable. I will finish my presentation with recommendations to improve the inventory process in the future.
-Euro Village is a fully serviced residential and office complex located in Khobar, Saudi Arabia. It was built in 1975 and has been expanding since then.-The compound purchases electricity from the Saudi Electricity Company and desalinates well water on site using Reverse Osmosis.- The compound contains 470 villas, 6 office buildings, 2 hotels, 3 workshops for maintenance, one school, one nursery, one gym, and 5 kitchens.
You see in this slide examples of the different types of facilities; In the top, two villas built in the 80’s and 90’s, in the bottom: an office building and a hotel built seven years ago.
This is a snapshot shot from google maps showing a satellite image of the compound.TRANSFORMATIONAL SENTENCE: Now that you have a picture of what this facility looks like, I can talk about the sources of emissions.
Scope 1 emissions are produced as a result of stationary combustion of LPG at the kitchen, ………. mobile combustion of diesel and gasoline, ……….. and fugitive emissions from the maintenance of AC systems. The maintenance group uses small quantity of CFC, which is not one of the six gases but I included it and treated it as an HFC.- The only Scope 2 source is purchased electricity.- I found many scope 3 sources but only calculated one source:…… employee travel.
Since the management of the has full control over the operational policies and pays for the bills, the operational control approach was determined to be most appropriate.It will enable the mgmt to implement necessary changes to reduce the carbon footprint.All offices and 4 kitchens are leased, where the compound is responsible for running everything including maintaining the buildings and appliances, utilities supplies, and pays for bills. It is an operating lease.
EV has over 600 monthly bills because it is treated by the Saudi Electricity Company as a residential sector. Almost each building has a meter. Sometimes a cluster of 4 or 5 buildings, depending on the demand of electricity, has one meter.The electric bills are managed as financial bills and electric consumption was not extract from the bills. To extract the amount of electricity consumption from the bills, one of the accounting assistant as well as myself went through all the bills from 2011.The LPG, Freon, bills were used to calculate the consumption bimonthly and monthly.Freon supplies were provided by the maintenance engineer.
STATIONARY COMBUSTION: To calculate emissions from stationary combustion of LPG, I used tier C method because I could not obtain the measured carbon or heat content. There is someuncertainties when choosing values of emissions based on the GRP values because the chemical and physical characteristics of the local products might be different from those sold in the USMOBILE COMBUSTION: The distance traveled by the fleet had to be estimated in order to calculate CH4 and N2O emissions. The accountant provided estimation of distance traveled by the fleet based fuel quantity and daily pattern provided by the accountant FUGITIVE EMISSIONS: I used Tier A method to calculate fugitive emissions because I obtained the actual consumption for both refrigerants. For HFC-22 and CFC-11, the GWP values were adopted from Refrigerant Management Program implemented by California Environmental Protection Agency.
Tier A method could not be used because neither the Saudi Electricity Company nor the government published information about the power plants. Because the electricity grid is fed from three different plants that use different fuels, I used the emission factors for electricity generation in Saudi Arabia for the period between1999 and 2002. I quoted the factors from the Energy Information Administration. These factors were calculated using the average emissions intensity of all power plants in Saudi Arabia and included Transmissions and Distribution losses.For Scope 3 employee travel, I utilized the reference for our first assignment, carbonfootprint.com. I assumed that employee travel stops at they city they landed at in their home country.
- In 2011, Euro Village contributed more than 53 thousand metric ton of CO2 equivalent as a result of the operations. More than 99% if the evaluated emissions were released as a result of electricity consumption and HFCs emissions. In the next few slides, I will describe the all of these emissions with emphasis on electricity and fugitive emissions.
- The first scope 1 emissions are released from LPG burners used in one kitchen, which is maintained by the management. The LPG burners released more than 23 metric ton of co2 equivalent in 2011. The gas is stored in a buried tank similar to that in the picture.
- The buses shown in the pictures are some of the sources of mobile combustion on the compound. Diesel and gasoline vehicles contributed 236 mtCO2e and represent less than 0.5% of the total emissions.
The total fugitive emissions topped 6,000 mtCO2e and account for more than 11% of the total emissions. As you can see from the pie charts, 9% of those emissions were caused by the consumption of 150 kg of CFC-11.- Likely, the HCFC-22 consumption of more than 3,700 kg resulted in more than 5500 of mtCO2e.
The graph shows scope 2 electricity consumption in 2011, which is the largest source representing 87% of the total emissions. It produced more than 47,000 metric ton CO2 equivalent.If you look at the red and blue lines, you can see the average summer consumption is about 6 million kWh, which is 70% more than the average winter consumption of just over 3.5 million kWh. When we talk about reduction, I will explain the best way to trim the top of this curve.
-Scope 3 emissions include those emissions from the leased kitchens, waste collection, employee commuting, business travel, sewage treatment and shipping of appliances and construction material to name a few.-The only scope 3 emissions I calculated was the employee travel. The employees are mostly expatriates who come from Nepal, India, and the Philippines and repatriate every two years. -In 2011, 105 employees traveled to their home countries for vacation according to the vacation records. I calculated the emissions released from all of those flights using carbonfootprint.com calculator.
TRANSITIONAL: Now I would like to talk about the best ways I found suitable to reduce the emissions of the compound. The first step that needs to be taken is including tracking and accounting of electricity consumption in the books.In order to track electricity consumption, having individual meters at each single facility is a must to link the facilities with the electricity bill. This can be done on an excel sheet that shows the account number, consumption and the corresponding housing unit. The monthly consumption of the whole compound should be accounted monthly and used to monitor the highest energy intensive units.These two steps will identify the units that can be improved to reduce the cost of energy and ultimately the emissions.
The performance of those high energy units can be tested by the Blower Door Test. it is an air tightness test where a large fan is placed at the main door to create negative pressure in a house. The test helps locate the sources of air leaks.Then a thermographic scan can be done to quantify the heat loss.The tracking, accounting and auditing of the unit energy demand is necessary to find the wasted energy and money and also maximize the investment by locating the most needy units.
TRANSITIONAL: Now let’s talk about improving the energy efficiency. For new construction or renovation of housing units, thermal insulation is the most important element. It should be examined carefully to maximize energy efficiency, particularly during wall and roof assemblies, insulation, and window selection.Old windows and slider doors should be replaced with lower U-factor windows, which can save up to 25% of the cooling energy.
ACs account for roughly 26% of the total electricity consumption. Replacing oldAcs, like the one shown in the picture, with high Seasonal Energy Efficiency Ratio (SEER) will reduce the cooling cost at least by 20% and would consequently.Include filter cleaning or replacement in the regular maintenance schedule to improve the efficiency by 5%.
Since EV provides full serviced housing, it owns thousands of appliances ranging from an exhaust fan to a microwave.Energy Star website includes energy ratings for all kinds of appliances and should be used to replace non-efficient appliances.Even within Energy Star certified appliances, some are more efficient that the others. So always look at labels or wattage for the lowest annual consumption Energy Star replacements must be considered as a factor in addition to performance, reliability and cost.
- For Acs R-22 can be replaced with R-134a, which has a lower GWP and can deliver comparable performance.- For refrigerators and chillers HFC-123 is an ideal replacement because it has a GWP of 90 compared to 3,800 for CFC11.
Upgrading the older parts of the compound and substituting refrigerants are the keys to reduce the emissions. The compound has the potential to reduce 20% of the emissions, which weighs more than 10,000 metric ton of CO2 equivalent.Quick wins listed in the slide can be implemented immediately. Investment in energy efficiency will be the bulk of the reduction.
- This inventory should be updated if more information is obtained about the consumption, recent emissions factors, carbon content of diesel or gasoline, or others related to the inventory.- If the compound decides to conduct a second inventory of 2012, ways to improve the quality should be considered. Improving the documentations, such as transportations records and maintenance history, will lead a more accurate assessment of the energy needs.
- Thank you for listening to me and wish you a good day.