PET MR Biomedical Engineers Perspective
1. Nicholas Plaxton, MD, MS
Emory University
October 11, 2013
PET/MRI
BIOMEDICAL ENGINEER’S PERSPECTIVE
2. First PET/MR
1990’s small-animal imaging
Multiple scans - decrease radiation exposure
San Raffaele Scientific Institute, Milano, Italy
3. Clinical PET/MR Development
Success of PET/CT in 2000’s
Better anatomic correlation
Improved attenuation correction techniques
PET/CT limited in soft tissue contrast
Brain lesions
Genitourinary cancers
Breast and colon cancers
PET/MR could provide superior soft tissue
contrast
4. Major Challenge in PET/MR
MR high field magnets interfere with PET
photomultiplier tube electrons
5. Types of PET/MR Scanners Developed
PET/CT and MR in attached rooms with
patient shuttled in between
PET and MR gantries arranged along axis
with patient handling system between
Integrated PET and MR
6. PET/CT and MR Suite
GE prototype 2010 installed in Zurich, Switzerland
PET/CT with patient shuttled into next room MR
Utilizes CT for attenuation correction
Cheaper
Can upgrade and use components independently
7. Hybrid PET/MR
Phillips Gemini 2012 coplanar PET TF with
platform rotation into MR
Minor shielding on PET
Installed in NYU, NY and Geneva, Switzerland
PET
MRI
MAGMA Nov 21, 2012
8. Integrated PET/MR
PET and MR imaged simultaneously without
moving patient
Excellent registration of PET and MR images
No time required to shuttle patient
Less physical space needed
Need to overcome electronic interference
10. Integrated Prototype PET/MR
Developed by Siemens in 2006
Utilized standard MR scanner
PET insert placed in MR bore
Multiple institution research project
University of Tubingen, Germany
Forschungszenrum Julich, Germany
Massachusetts General Hospital, Boston, MA
Emory University, Atlanta, GA
11. BrainPET by Siemens
PET insert ring into MR
35.5cm diameter ring with 2.5mm LSO crystals
Coupled with Avalanche Photo Diodes (APD)
MAGMA Nov 21, 2012
13. First PET/MR Image in 2006
66 y/o female with Siemens BrainPET
J Nucl Med 2012; 53:1916–1925
14. Siemens Biograph mMR
2010 Siemens developed whole body PET with
3-T MR with a 60 cm gantry (Biograph mMR)
FDA approved for purchase in 2011
MAGMA Nov 21, 2012
16. Institutions using Biograph mMR
Mass. General Hospital - Boston, MA
NIH - Bethesda, MD
Washington University, St. Louis, MO
UNC, Chapel Hill, NC
UPMC, Pittsburgh, PA
NYU, New York City
Mt. Sinai Univ, NYC
Univ Hospital Stonybrook, NYC
17. Benefits of PET/MR
Soft-tissue characterization
Lower ionization than PET/CT
Questionable benefit for oncology patients
MR breast imaging has high sensitivity but
low specificity, FDG PET has high specificity
but low sensitivity, therefore benefit
combining PET/MR
18. Disadvantages of PET/MR
Attenuation correction with MR
Image truncation, RF coils
Longer acquisition and multiple sequences
TOF can shorten PET acquisition time
MR sequences would need to be limited
2 to 5 sequences per study takes ~ 30 min
Total time of 1 hour still shorter than separate studies
Incapable with metal artifacts (pacers or implants)
Claustrophobia
CT superior for lung imaging
19. Types of Attenuation Correction
Template based
Atlas based
Direct Segmentation
Sequence Segmentation
24. Sequence Segmentation Attenuation
Ultrashort echo time
(UTE) sequences
Developed for very short
spin–spin relaxation times
Distinguish bone from air
Seconds to acquire each
bed position
MAGMA Nov 21, 2012
25. Oncologic Applications PET/MR
Liver and bone metastases
Brain tumors
Prostate cancer
Gynecological cancers
Breast cancer
Head and Neck cancers
35. Take Home Message
PET/ MR emerging cutting edge technology
Applications being developed alongside novel
radiotracers
PET/MR will not replace PET/CT