SlideShare ist ein Scribd-Unternehmen logo
1 von 27
Radiographic image
Quality
by astuti mishra
08/04/17 1
QUALITY OF RADIOGRAPH
 Is the exactness of representation of the patient’s
anatomy on the radiograph
 The most important characteristics of radiographic
quality are
sharpness/unsharpness,contrast,resolution,noise,size of
image(magnification and distortion) and artifacts.
High spatial and contrast resolution require low noise
and slow image receptors
2
08/04/17 3
08/04/17 4
Characteristics of Radiographic Quality
08/04/17 5
Sharpness/Unsharpness
Contrast
Resolution
Noise
Size of image
Artifacts
6
1. Geometric(G)
a) Focal size
b) Focus-object distance
c) Focus-film distance
2. Object factor(O)
3. Intrinsic factor(I)
a) Grain size of film
b) Grain size of I. Screen
4. Movement (M)
a) ~ of tube
b) ~ of object
c) ~ of film
5. Total unsharpness
=G+I+O+M
Sharpness/Unsharpness
(factors)
08/04/17 7
1.Geometric unsharpness
As penumbra(partial shadows) increases with an increased focal spot
size,increased object- to- film distance and decreased focus-to-film
distance;the degree of geometric unsharpness increases.
Geometric unsharoness=FOD/FFD×Focal spot size
2.Object factor(o)
X-ray absorption vary across the object
due to the shape of the structures in the
body.
As most structures in the body have a
round edge,the gradual fall-off in
absorption towards edge leads to the
absorption unsharpness.
08/04/17 8
3.Intrinsic factor(I)
a. Duplitized film produce more unsharpness than single-sided emulsion
due to crossing over effect.
b. Spread of light will be greater with larger crystals of
screen(regular/fast screen) and will be greater with increasing
distance between crystals and film(poor film/screen contact) which
increases unsharpness.
4.Movement unsharpness(M)
Is due to patient,equipment or film movement during the
Expoxure
Can be minimized by using short-expoxure time,small FOD
and particularly by immobilization(using various accessories i.e.
pads,sand bags,binders,velero staps).
…cont..
08/04/17 9
08/04/17 10
08/04/17 11
08/04/17 12
08/04/17 13
•Subject contrast
•Exposure
•Scattered Radiation
•Development
•Image-acquisition
device
Subjective contrast
•The observer
•Viewing conditions
•Radiographic
Contrast
Radiographic/Objective
contrast
Factors Factors
•Region of body under examination
•Contrast media
•Pathology
•KV[α 1/sbj contrast]
Subject Contrast
Factors
Contrast
Subject contrast
Is a feature of the object(subject) under examination. The
different irradiation intensities emerging from the spatial
distribution of linear attenuation coefficients within the
object.
Factors affecting sc
The region the body under examination
Contrast media
Pathology –if the density of a structure is changed due to
pathology then there will be a change in subject contrast
Kv
Kv<1/subject contrast
08/04/17 14
2.subjective contrast
The personal appreciation of the contrast in the image is
called subjective contrast. It depends on:
The observer :visual perception, fatigue etc
Viewing conditions: e.g. ambient lighting
3.Radiographic contrast(objective)
Is the difference in OD on different parts of processed film or
diff. in computer screen brightness recorded as a result of the
range of emergent beam intensities.
08/04/17 15
Factors affecting RC
• Subject contrast
•Exposure – if too much or too little radiation is used ,there may be a
reduced range of densities visible on the image , thus radiographic
contrast will be reduced or non-existent.
•Scattered radiation reaching the image receptor –the use of grid lead
–backed cassette , lead rubber under cassette ,air gap technique ;may
reduce scatter radiation reaching IR which improve radiographic
contrast.
•Development – to achieve optimum RC ,careful control of factors such
as developer temperature, development time and processing chemical
activity is needed.
•Image acquisition device – the design and function of the device used
to acquire the image such as certain types of film emulsion ,intensifying
screen and phosphor plate ,software in digital system can have
profound effect on contrast .
08/04/17 16
Resolution
The ability to demonstrate closely spaced structures in the
subject as separate entities on the image .
It depend on contrast ,unsharpness , noise and speed .
Noise
The random fluctuation in the OD of the image
3 kinds of image noise
•Fog-due to the presence of scattered radiation
•Quantum noise –due to quantum nature of x-ray beam
•Electric noise –due to limitations in electronic processing of
the image08/04/17 17
Tools for improved radiographic
qualityRT normally has the tools available to produce high –
quality radiograph
For any given radiographic examination , a proper
interpretation and application of following factors must be
available :
•Patient positioning
 The anatomical structure under examination must be
close to IR
 CR should be incident on the centre of the structure
 The patient must be effectively immobilized to minimize
motion blur
08/04/17 18
Image receptors
•In general ,extremity and soft tissue ,a fine detail screen film
combination is used
•Most other radiographs use double emulsion film with screens
•The new ,structured- grain x-ray films used with high resolution
intensifying screens produce exquisite images with limited patient dose
Selection of technical factors
•Before any examination ,RT must select the optimum radiographic
technique factors :KVp, mAs and exposure time
•Image quality is improved with short exposure with the use of three-
phase and high frequency generators as result of reduced motion blur
•Adding filtration reduces the beam intensity but increases the quality
•Different types of grids are used to improve image contrast
08/04/17 19
08/04/17 20
Image artifacts
 Are undesirable optical densities or blemishes on a radiograph or any
other medical image
 Can interference with anatomical structures and lead to misdiagnose
Processing artifacts
• Emulsion pickoff
• Gelatin build up
• Curtain effect
• Chemical fog
• Guide shoe marks
• Pi-lines
• Wet pressure sensitization
• Diachronic stain
08/04/17 21
Exposure artifacts
•Motion
•Improper pt positioning
•Wrong screen film match
•Poor screen contact
•Double exposure
•Warped cassette
•Improper grid positioning
Handling and storage artifacts
•Light fog
•Radiation fog
•Static
•Kink marks
•Hypo retention stain
•Scratches
08/04/17 22
08/04/17 23
Size of image
Magnification
• If FOD is increased ,FFD should increase to reduce
magnification
• Magnification =image size /object size =FFD/FOD
Image distortion
• A distorted image will produced if not all parts of
the image are magnified by the same amount
08/04/17 24
08/04/17 25
References
•Clark’posotioning in radiography
•Radiological science for technologists
•Encyclopedia of radiographic
positioning
•internet
08/04/17 26
Thank you……….
08/04/17 27

Weitere ähnliche Inhalte

Was ist angesagt?

Sensitometry or characteristic curve
Sensitometry or characteristic curve   Sensitometry or characteristic curve
Sensitometry or characteristic curve
Upakar Paudel
 
Intensifying screens
Intensifying screensIntensifying screens
Intensifying screens
Eddy Rumhadi
 

Was ist angesagt? (20)

Radiographic grid Swastik
Radiographic grid   SwastikRadiographic grid   Swastik
Radiographic grid Swastik
 
Sensitometry or characteristic curve
Sensitometry or characteristic curve   Sensitometry or characteristic curve
Sensitometry or characteristic curve
 
Screen Film Radiography
Screen Film RadiographyScreen Film Radiography
Screen Film Radiography
 
Faults in x ray tube and its care
Faults in x ray tube and its careFaults in x ray tube and its care
Faults in x ray tube and its care
 
Computed radiography
Computed radiographyComputed radiography
Computed radiography
 
The control of scattered radiation
The control of scattered radiationThe control of scattered radiation
The control of scattered radiation
 
Computed radiography
Computed radiographyComputed radiography
Computed radiography
 
Grids
GridsGrids
Grids
 
X ray tube, cassette and screens
X ray tube, cassette and screensX ray tube, cassette and screens
X ray tube, cassette and screens
 
CT detectors
CT detectorsCT detectors
CT detectors
 
Dark room equipments and entrance
Dark room equipments and entranceDark room equipments and entrance
Dark room equipments and entrance
 
CT ARTIFACTS.pptx
CT ARTIFACTS.pptxCT ARTIFACTS.pptx
CT ARTIFACTS.pptx
 
Filters
FiltersFilters
Filters
 
Fluoroscopy
 Fluoroscopy  Fluoroscopy
Fluoroscopy
 
Enteroclysis( small bowel enema)
Enteroclysis( small bowel enema)Enteroclysis( small bowel enema)
Enteroclysis( small bowel enema)
 
X ray tube
X ray tubeX ray tube
X ray tube
 
Intensifying Screen (x-ray)
Intensifying Screen (x-ray)Intensifying Screen (x-ray)
Intensifying Screen (x-ray)
 
Intensifying screens
Intensifying screensIntensifying screens
Intensifying screens
 
CR & DR
CR & DRCR & DR
CR & DR
 
TLD
TLDTLD
TLD
 

Ähnlich wie radiographic Image quality by Astuti Mishra

Radiographic image4
Radiographic image4Radiographic image4
Radiographic image4
mr_koky
 
Portal Imaging used to clear setup uncertainty
Portal Imaging used to clear setup uncertaintyPortal Imaging used to clear setup uncertainty
Portal Imaging used to clear setup uncertainty
MajoVJJose
 
L08 Image Quality
L08 Image QualityL08 Image Quality
L08 Image Quality
lidgor
 
L08 Image Quality
L08 Image QualityL08 Image Quality
L08 Image Quality
lidgor
 

Ähnlich wie radiographic Image quality by Astuti Mishra (20)

Cone beam computed tomography (2)
Cone beam computed tomography (2)Cone beam computed tomography (2)
Cone beam computed tomography (2)
 
factor affecting quality of radiograph
factor affecting quality of radiographfactor affecting quality of radiograph
factor affecting quality of radiograph
 
Radiographic image4
Radiographic image4Radiographic image4
Radiographic image4
 
L40 film and film less techniques
L40 film and film less techniquesL40 film and film less techniques
L40 film and film less techniques
 
Cone beam ct
Cone beam ctCone beam ct
Cone beam ct
 
X-ray Machine
X-ray Machine X-ray Machine
X-ray Machine
 
Cone beam computed tomography
Cone beam computed tomographyCone beam computed tomography
Cone beam computed tomography
 
IMAGE QUALITY.pptx
IMAGE QUALITY.pptxIMAGE QUALITY.pptx
IMAGE QUALITY.pptx
 
Cbct
CbctCbct
Cbct
 
Ndtm 5
Ndtm 5Ndtm 5
Ndtm 5
 
Image quality
Image qualityImage quality
Image quality
 
Digital Radiography
Digital RadiographyDigital Radiography
Digital Radiography
 
Portal Imaging used to clear setup uncertainty
Portal Imaging used to clear setup uncertaintyPortal Imaging used to clear setup uncertainty
Portal Imaging used to clear setup uncertainty
 
L08 Image Quality
L08 Image QualityL08 Image Quality
L08 Image Quality
 
L08 Image Quality
L08 Image QualityL08 Image Quality
L08 Image Quality
 
Cone beam ct
Cone beam ctCone beam ct
Cone beam ct
 
Time-resolved mirrorless scintillation detector @ KSMPRS2018
Time-resolved mirrorless scintillation detector @ KSMPRS2018Time-resolved mirrorless scintillation detector @ KSMPRS2018
Time-resolved mirrorless scintillation detector @ KSMPRS2018
 
geometric Factors
 geometric Factors geometric Factors
geometric Factors
 
Image characteristics,latent image,film processing.
Image characteristics,latent image,film processing.Image characteristics,latent image,film processing.
Image characteristics,latent image,film processing.
 
Ideal radiography
Ideal radiographyIdeal radiography
Ideal radiography
 

Mehr von bp.koirala institute of health science (10)

Age related changes in relation to reproductive system
Age related changes in relation to reproductive systemAge related changes in relation to reproductive system
Age related changes in relation to reproductive system
 
Article
ArticleArticle
Article
 
Body planes and body cavities (anatomy)
Body planes and body cavities (anatomy)Body planes and body cavities (anatomy)
Body planes and body cavities (anatomy)
 
Bmit. 2014.staffing
Bmit. 2014.staffingBmit. 2014.staffing
Bmit. 2014.staffing
 
Legal responsibility
Legal responsibilityLegal responsibility
Legal responsibility
 
Tracheostomy (2)
Tracheostomy (2)Tracheostomy (2)
Tracheostomy (2)
 
2. medical and surgical aspesis
2. medical and surgical aspesis2. medical and surgical aspesis
2. medical and surgical aspesis
 
Mri safety (1)
Mri safety (1)Mri safety (1)
Mri safety (1)
 
X ray tube
X ray tubeX ray tube
X ray tube
 
Mri contrast
Mri contrastMri contrast
Mri contrast
 

Kürzlich hochgeladen

Kürzlich hochgeladen (20)

The Most Attractive Hyderabad Call Girls Kothapet 𖠋 9332606886 𖠋 Will You Mis...
The Most Attractive Hyderabad Call Girls Kothapet 𖠋 9332606886 𖠋 Will You Mis...The Most Attractive Hyderabad Call Girls Kothapet 𖠋 9332606886 𖠋 Will You Mis...
The Most Attractive Hyderabad Call Girls Kothapet 𖠋 9332606886 𖠋 Will You Mis...
 
Call Girls Gwalior Just Call 8617370543 Top Class Call Girl Service Available
Call Girls Gwalior Just Call 8617370543 Top Class Call Girl Service AvailableCall Girls Gwalior Just Call 8617370543 Top Class Call Girl Service Available
Call Girls Gwalior Just Call 8617370543 Top Class Call Girl Service Available
 
♛VVIP Hyderabad Call Girls Chintalkunta🖕7001035870🖕Riya Kappor Top Call Girl ...
♛VVIP Hyderabad Call Girls Chintalkunta🖕7001035870🖕Riya Kappor Top Call Girl ...♛VVIP Hyderabad Call Girls Chintalkunta🖕7001035870🖕Riya Kappor Top Call Girl ...
♛VVIP Hyderabad Call Girls Chintalkunta🖕7001035870🖕Riya Kappor Top Call Girl ...
 
Premium Bangalore Call Girls Jigani Dail 6378878445 Escort Service For Hot Ma...
Premium Bangalore Call Girls Jigani Dail 6378878445 Escort Service For Hot Ma...Premium Bangalore Call Girls Jigani Dail 6378878445 Escort Service For Hot Ma...
Premium Bangalore Call Girls Jigani Dail 6378878445 Escort Service For Hot Ma...
 
Call Girls Dehradun Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Dehradun Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Dehradun Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Dehradun Just Call 9907093804 Top Class Call Girl Service Available
 
Call Girls Cuttack Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Cuttack Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Cuttack Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Cuttack Just Call 9907093804 Top Class Call Girl Service Available
 
Mumbai ] (Call Girls) in Mumbai 10k @ I'm VIP Independent Escorts Girls 98333...
Mumbai ] (Call Girls) in Mumbai 10k @ I'm VIP Independent Escorts Girls 98333...Mumbai ] (Call Girls) in Mumbai 10k @ I'm VIP Independent Escorts Girls 98333...
Mumbai ] (Call Girls) in Mumbai 10k @ I'm VIP Independent Escorts Girls 98333...
 
Best Rate (Guwahati ) Call Girls Guwahati ⟟ 8617370543 ⟟ High Class Call Girl...
Best Rate (Guwahati ) Call Girls Guwahati ⟟ 8617370543 ⟟ High Class Call Girl...Best Rate (Guwahati ) Call Girls Guwahati ⟟ 8617370543 ⟟ High Class Call Girl...
Best Rate (Guwahati ) Call Girls Guwahati ⟟ 8617370543 ⟟ High Class Call Girl...
 
(👑VVIP ISHAAN ) Russian Call Girls Service Navi Mumbai🖕9920874524🖕Independent...
(👑VVIP ISHAAN ) Russian Call Girls Service Navi Mumbai🖕9920874524🖕Independent...(👑VVIP ISHAAN ) Russian Call Girls Service Navi Mumbai🖕9920874524🖕Independent...
(👑VVIP ISHAAN ) Russian Call Girls Service Navi Mumbai🖕9920874524🖕Independent...
 
Call Girls Tirupati Just Call 8250077686 Top Class Call Girl Service Available
Call Girls Tirupati Just Call 8250077686 Top Class Call Girl Service AvailableCall Girls Tirupati Just Call 8250077686 Top Class Call Girl Service Available
Call Girls Tirupati Just Call 8250077686 Top Class Call Girl Service Available
 
Book Paid Powai Call Girls Mumbai 𖠋 9930245274 𖠋Low Budget Full Independent H...
Book Paid Powai Call Girls Mumbai 𖠋 9930245274 𖠋Low Budget Full Independent H...Book Paid Powai Call Girls Mumbai 𖠋 9930245274 𖠋Low Budget Full Independent H...
Book Paid Powai Call Girls Mumbai 𖠋 9930245274 𖠋Low Budget Full Independent H...
 
Best Rate (Patna ) Call Girls Patna ⟟ 8617370543 ⟟ High Class Call Girl In 5 ...
Best Rate (Patna ) Call Girls Patna ⟟ 8617370543 ⟟ High Class Call Girl In 5 ...Best Rate (Patna ) Call Girls Patna ⟟ 8617370543 ⟟ High Class Call Girl In 5 ...
Best Rate (Patna ) Call Girls Patna ⟟ 8617370543 ⟟ High Class Call Girl In 5 ...
 
Call Girls Haridwar Just Call 8250077686 Top Class Call Girl Service Available
Call Girls Haridwar Just Call 8250077686 Top Class Call Girl Service AvailableCall Girls Haridwar Just Call 8250077686 Top Class Call Girl Service Available
Call Girls Haridwar Just Call 8250077686 Top Class Call Girl Service Available
 
Top Rated Hyderabad Call Girls Erragadda ⟟ 9332606886 ⟟ Call Me For Genuine ...
Top Rated  Hyderabad Call Girls Erragadda ⟟ 9332606886 ⟟ Call Me For Genuine ...Top Rated  Hyderabad Call Girls Erragadda ⟟ 9332606886 ⟟ Call Me For Genuine ...
Top Rated Hyderabad Call Girls Erragadda ⟟ 9332606886 ⟟ Call Me For Genuine ...
 
Call Girls Bareilly Just Call 8250077686 Top Class Call Girl Service Available
Call Girls Bareilly Just Call 8250077686 Top Class Call Girl Service AvailableCall Girls Bareilly Just Call 8250077686 Top Class Call Girl Service Available
Call Girls Bareilly Just Call 8250077686 Top Class Call Girl Service Available
 
Premium Call Girls Cottonpet Whatsapp 7001035870 Independent Escort Service
Premium Call Girls Cottonpet Whatsapp 7001035870 Independent Escort ServicePremium Call Girls Cottonpet Whatsapp 7001035870 Independent Escort Service
Premium Call Girls Cottonpet Whatsapp 7001035870 Independent Escort Service
 
Top Quality Call Girl Service Kalyanpur 6378878445 Available Call Girls Any Time
Top Quality Call Girl Service Kalyanpur 6378878445 Available Call Girls Any TimeTop Quality Call Girl Service Kalyanpur 6378878445 Available Call Girls Any Time
Top Quality Call Girl Service Kalyanpur 6378878445 Available Call Girls Any Time
 
Premium Call Girls In Jaipur {8445551418} ❤️VVIP SEEMA Call Girl in Jaipur Ra...
Premium Call Girls In Jaipur {8445551418} ❤️VVIP SEEMA Call Girl in Jaipur Ra...Premium Call Girls In Jaipur {8445551418} ❤️VVIP SEEMA Call Girl in Jaipur Ra...
Premium Call Girls In Jaipur {8445551418} ❤️VVIP SEEMA Call Girl in Jaipur Ra...
 
O963O942363 Call Girls In Ahmedabad Escort Service Available 24×7 In Ahmedabad
O963O942363 Call Girls In Ahmedabad Escort Service Available 24×7 In AhmedabadO963O942363 Call Girls In Ahmedabad Escort Service Available 24×7 In Ahmedabad
O963O942363 Call Girls In Ahmedabad Escort Service Available 24×7 In Ahmedabad
 
(Low Rate RASHMI ) Rate Of Call Girls Jaipur ❣ 8445551418 ❣ Elite Models & Ce...
(Low Rate RASHMI ) Rate Of Call Girls Jaipur ❣ 8445551418 ❣ Elite Models & Ce...(Low Rate RASHMI ) Rate Of Call Girls Jaipur ❣ 8445551418 ❣ Elite Models & Ce...
(Low Rate RASHMI ) Rate Of Call Girls Jaipur ❣ 8445551418 ❣ Elite Models & Ce...
 

radiographic Image quality by Astuti Mishra

  • 2. QUALITY OF RADIOGRAPH  Is the exactness of representation of the patient’s anatomy on the radiograph  The most important characteristics of radiographic quality are sharpness/unsharpness,contrast,resolution,noise,size of image(magnification and distortion) and artifacts. High spatial and contrast resolution require low noise and slow image receptors 2
  • 5. Characteristics of Radiographic Quality 08/04/17 5 Sharpness/Unsharpness Contrast Resolution Noise Size of image Artifacts
  • 6. 6 1. Geometric(G) a) Focal size b) Focus-object distance c) Focus-film distance 2. Object factor(O) 3. Intrinsic factor(I) a) Grain size of film b) Grain size of I. Screen 4. Movement (M) a) ~ of tube b) ~ of object c) ~ of film 5. Total unsharpness =G+I+O+M Sharpness/Unsharpness (factors)
  • 7. 08/04/17 7 1.Geometric unsharpness As penumbra(partial shadows) increases with an increased focal spot size,increased object- to- film distance and decreased focus-to-film distance;the degree of geometric unsharpness increases. Geometric unsharoness=FOD/FFD×Focal spot size 2.Object factor(o) X-ray absorption vary across the object due to the shape of the structures in the body. As most structures in the body have a round edge,the gradual fall-off in absorption towards edge leads to the absorption unsharpness.
  • 8. 08/04/17 8 3.Intrinsic factor(I) a. Duplitized film produce more unsharpness than single-sided emulsion due to crossing over effect. b. Spread of light will be greater with larger crystals of screen(regular/fast screen) and will be greater with increasing distance between crystals and film(poor film/screen contact) which increases unsharpness. 4.Movement unsharpness(M) Is due to patient,equipment or film movement during the Expoxure Can be minimized by using short-expoxure time,small FOD and particularly by immobilization(using various accessories i.e. pads,sand bags,binders,velero staps). …cont..
  • 13. 08/04/17 13 •Subject contrast •Exposure •Scattered Radiation •Development •Image-acquisition device Subjective contrast •The observer •Viewing conditions •Radiographic Contrast Radiographic/Objective contrast Factors Factors •Region of body under examination •Contrast media •Pathology •KV[α 1/sbj contrast] Subject Contrast Factors Contrast
  • 14. Subject contrast Is a feature of the object(subject) under examination. The different irradiation intensities emerging from the spatial distribution of linear attenuation coefficients within the object. Factors affecting sc The region the body under examination Contrast media Pathology –if the density of a structure is changed due to pathology then there will be a change in subject contrast Kv Kv<1/subject contrast 08/04/17 14
  • 15. 2.subjective contrast The personal appreciation of the contrast in the image is called subjective contrast. It depends on: The observer :visual perception, fatigue etc Viewing conditions: e.g. ambient lighting 3.Radiographic contrast(objective) Is the difference in OD on different parts of processed film or diff. in computer screen brightness recorded as a result of the range of emergent beam intensities. 08/04/17 15
  • 16. Factors affecting RC • Subject contrast •Exposure – if too much or too little radiation is used ,there may be a reduced range of densities visible on the image , thus radiographic contrast will be reduced or non-existent. •Scattered radiation reaching the image receptor –the use of grid lead –backed cassette , lead rubber under cassette ,air gap technique ;may reduce scatter radiation reaching IR which improve radiographic contrast. •Development – to achieve optimum RC ,careful control of factors such as developer temperature, development time and processing chemical activity is needed. •Image acquisition device – the design and function of the device used to acquire the image such as certain types of film emulsion ,intensifying screen and phosphor plate ,software in digital system can have profound effect on contrast . 08/04/17 16
  • 17. Resolution The ability to demonstrate closely spaced structures in the subject as separate entities on the image . It depend on contrast ,unsharpness , noise and speed . Noise The random fluctuation in the OD of the image 3 kinds of image noise •Fog-due to the presence of scattered radiation •Quantum noise –due to quantum nature of x-ray beam •Electric noise –due to limitations in electronic processing of the image08/04/17 17
  • 18. Tools for improved radiographic qualityRT normally has the tools available to produce high – quality radiograph For any given radiographic examination , a proper interpretation and application of following factors must be available : •Patient positioning  The anatomical structure under examination must be close to IR  CR should be incident on the centre of the structure  The patient must be effectively immobilized to minimize motion blur 08/04/17 18
  • 19. Image receptors •In general ,extremity and soft tissue ,a fine detail screen film combination is used •Most other radiographs use double emulsion film with screens •The new ,structured- grain x-ray films used with high resolution intensifying screens produce exquisite images with limited patient dose Selection of technical factors •Before any examination ,RT must select the optimum radiographic technique factors :KVp, mAs and exposure time •Image quality is improved with short exposure with the use of three- phase and high frequency generators as result of reduced motion blur •Adding filtration reduces the beam intensity but increases the quality •Different types of grids are used to improve image contrast 08/04/17 19
  • 21. Image artifacts  Are undesirable optical densities or blemishes on a radiograph or any other medical image  Can interference with anatomical structures and lead to misdiagnose Processing artifacts • Emulsion pickoff • Gelatin build up • Curtain effect • Chemical fog • Guide shoe marks • Pi-lines • Wet pressure sensitization • Diachronic stain 08/04/17 21
  • 22. Exposure artifacts •Motion •Improper pt positioning •Wrong screen film match •Poor screen contact •Double exposure •Warped cassette •Improper grid positioning Handling and storage artifacts •Light fog •Radiation fog •Static •Kink marks •Hypo retention stain •Scratches 08/04/17 22
  • 24. Size of image Magnification • If FOD is increased ,FFD should increase to reduce magnification • Magnification =image size /object size =FFD/FOD Image distortion • A distorted image will produced if not all parts of the image are magnified by the same amount 08/04/17 24
  • 26. References •Clark’posotioning in radiography •Radiological science for technologists •Encyclopedia of radiographic positioning •internet 08/04/17 26