AIRSYS Refrigeration Engineering Technology (Beijing) Co.,Ltd
AIRSYS-P-SC-GENERAL-E1408V01.5
AIRSYS
Expert in ICT Cooling
2
Brief Introduction
Airsys is a world major player in ICT cooling with a wide range of
product including Precision Air-conditioner for computer room and data
center, air-conditioner and Intelligent Free Cooling unit for BTS station,
air-conditioner and heat exchanger for various type of cabinets, chillers
for data center cooling source. All product is highly reliable and energy
efficient.
Airsys provide the full solution and service to its customer such as
product selection, design and development, manufacturing, installation,
after-sale service and contract operation.
1995
Founded in Beijing as the distributor
of a major European ICT cooling
manufacturer, established the
national sales & distribution
network.
2001
ISO9001 certified. Introduced
Airsys Brand Precision Air-
conditioner.
2008
New GuAnproduction facility
completed, 30,000 sqm of covered
plant and 80,000 sqm of total area,
became one of the leader in ICT
cooling.
“2008 Technology Innovation
Award for Green Telecom China”
Became global supplier for
Siemens Healthcare.
2009
Became global s
supply various IC
1999
Introduced Airsys Brand chiller and
become a HVAC manufacturer.
2007
Obtained the record making
shelter air-conditioner PO from
Reliance Communication, an
Indian telecom operation.
Became strategic partner of
China Mobile to develop the high
energy efficient air-conditioner for
its green shelter project.
3
2006
Attended the ITU exhibition and
started the strategic development of
the international market.
2010
The packaged outdoor shelter air-
conditioner passed the quality audit
and on site energy efficiency test of
Verizon Wireless, became a part of
their new shelter HVAC standard.
Became its first Chinese supplier and
start the bunch supply.
2011
Became the global supplier for
Philips Healthcare and got well
acknowledged by the customer.
Became the global supplier of
British Telecom, providing site
survey, installation with the newly
established Airsys UK.
supplier of Vodafone,
CT cooling products.
2003
Elected as “Best Employer” by
<Fortune> Chinese Edition.
Became global supplier for
GE Healthcare and got the
“Technology Innovation Award” of
the year.
2004
New production facility in Beijing
completed.
4
Core Value
Reliability means supplying reliable products and services and winning trusts
from happy customers in order to win the market.
Efficiency means optimizing resource distribution to ensure sustainable
business development and maximizing profit margins.
Responsibility means being responsible to shareholders, customers,
employees, suppliers, and the society in large.
Respect means respecting to shareholders, customers, employees,
suppliers and partners.
Reliability
Efficiency
Responsibility
Respect
Vision
A major global supplier of product and service in ICT and related industries.
AIRSYS will always devote to fulfill the social responsibility of all aspects, providing
more environment friendly products, protecting the sustainable development of global
environment. Also,we contribute to the development of region and happiness, health
and sustainable development of employees and their families.
Social Responsibility
5
Manufacturing Facility
As the largest ICT cooling product manufacturing facility in Asia, Airsys GuAn has
a total area of 80,000 sqm among which 30,000 sqm are covered plant. Equipped
with production line for heat exchanger, sheet metal, powder painting, assembly line
and performance test chamber, this facility can produce different type of ICT cooling
product or more than 100,000 units a year.
Energy Saving
World is facing the challenge of energy shortage, especially in ICT industry,the revolution in
information storage, processing and transmission result more and more energy consumption.
Energy efficiency has always been the core value and responsibility of Airsys. We use various
kind of technologies, such as free cooling chiller, air-conditioner, independent free cooling unit, EC
fan, DC compressor, battery cooler, scroll compressor and displacement air distribution scheme,
to help our customer to cut their energy bill
High Reliability
ICT environment cooling requires high reliability. Airsys has always taken reliability
as the most important value and build into every aspect of our business process
and every employee’s mind. We assure every product produced is highly reliable by
selection of component, design validation, IE and QC, 100% test, process control on
installation and service. Our product meet various international standard such as CE,
UL, RoHS, CCC.
Research and Development
Our R&D team is formed by experienced HVAC AND electric engineers. Apart from the standard
products, we have rich experience in developing custom made products for our customer. We
can quickly deliver the technical proposal, prototype, laboratory performance test report and real
site test according to customer’s requirement.
Service Network
Airsys has a well established service network throughout China and major international
regions. Our team, call center and CRM platform provide fast and professional service
covering installation, emergency intervention, maintenance, contract operation, online
failure analysis, IAQ analysis.
6
Telecom Operator – Verizon Wireless
Gone through 3 years of real site testing, highly recognized
by the customer for its reliability, energy efficiency and
overall performance. Specified in the new Verizon Wireless
Shelter standard. Become its first Chinese supplier.
Telecom Equipment Supplier- ZTE
Long Term Partner
Supply all range of product from Cabinet cooling to Data
Center cooling.
ICT Power Equipment Supplier-Delta, Eltek
Strategic Partner
Supply all range of cooling product from cabinet to data
center.
Data Center Operator, Internet Companies
Supply full solution for Data Center.
Telecom Operator – China Mobile
Major Cooling Supplier
Strategic Partner for “Green Action Plan”
Research and consulting service on shelter cooling energy
saving and related standard, developing the software for
energy saving calculation, product.
Supply CRAC for its large Data Center.
Telecom Operator – China Telecom
Major Cooling Supplier
Long Term Partner, supply CRAC for its large Data Center.
Telecom Operator – Vodafone
Global Cooling Supplier
Jointly develop various cooling product with significant
energy saving features.
Help to improve both CAPEX and OPEX
Telecom Operator – British Telecom
Global Cooling Supplier
Develop custom made cooling product.
Provide turnkey solution including site survey, installation,
and product supply.
Telecom Operator –Reliance Communication
Strategic Cooling Supplier
Completed Design, Prototype and Pilot order within 3
months, delivered 25,000 units within 12 months period.
The units have shown the best of its kind in terms of failure
rate, energy consumption in the market of India.
Won the Best Supplier Award in year 2007 and 2008.
Airsys and ICT Industry
7
Sales and service network
Technical Support and Logistic Center
EU-CIS-India
North America
Middle East & Africa
Sales & Distribution
Asia Pacific: India, Pakistan, Nepal, Australia,
Singapore, Indonesia, Malaysia, Vietnam, Philipine
EMEA: Russia, France, UK, Romania, Spain, Czek,
Italy, Turkey, South Africa, Nigeria.
Americas: USA, Canada, Mexico, Peru, Ecuador.
Airsys Refrigeration Engineering Technology
(Beijing) Co.,Ltd
Gu'an Airsys Environmental Technology Co. Ltd
Shanghai Airserve HVAC Systerm Service Co., Ltd.
Airsys Group (HK) Co., Ltd.
Airsys (UK) Ltd.
8
Airsys product &solutions
Data CenterTelecom ShelterCabinet
MOBILECOOL-OUTDOOR
Cooling capacity:3.5~17.9 kW
MOBILECOOL-SPLIT
Cooling capacity:5.5~14.9kW
METROCOOL
Cooling capacity:5.2~13.0kW
Outdoor condenser and dry cooler
Cooling capacity:9.3~83.1 kW
FREECOOL
Air flow: 1000~3450 m3
/h
FREECOOL-HD
Air flow: 2400~21600 m3
/h
MOBILECOOL-INDOOR
Cooling capacity:3.4~13.3 kW
OPTIMA-HD.CW/CWD
Cooling capacity:42.1~180.9 kW
TELECOOL
Cooling capacity:0.3~3kW
DATACOOL-PACKAGE
Cooling capacity:9.1~48.6 kW
DATACOOL
Cooling capacity:5.8~30.2 kW
HYDROCOOL
Cooling capacity:229.5~3641.2 kW
CRITICOOL
Cooling capacity:115~1508 kW
CRITICOOL-FC
Cooling capacity:114~1493 kW
Ventilation
& Heat
Exchanger
Chiller
Air-
conditioner
OPTIMA.DXA/DXW
Cooling capacity:17.6~106.7kW
OPTIMA-INV.DXA/DXW
Cooling capacity:16.3~115.4kW
OPTIMA.CW/CWD
Cooling capacity:24.8~134.5kW
OPTIMA-FC.DXA/DXW
Cooling capacity:17.6~106.7kW
OPTIMA-FC-INV.DXA/DXW
Cooling capacity:16.1~115.4kW
9
OPTIMA/OPTIMA-INV
OPTIMA.DXA/DXW
OPTIMA family includes standard series of OPTIMA and DC inverter series
of OPTIMA-INV, is applicable to large and medium-sized data center and
electronic equipment room. It has a wide range cooling capacity, high
operating reliability and stability. Equipped with EC fan, precise control of
temperature ±1℃, relative humidity ±5% which can assure the reliable and
stable environment of the data room.
Standard series of OPTIMA has various type of cooling system, direct
expansion with air-cooled condenser, direct expansion with water-cooled
condenser, chilled water with either single coil or double coil. DC inverter
series of OPTIMA-INV has two types of cooling schemes: direct expansion
with air-cooled condensers, direct expansion with water-cooled condenser.
There are up flow and down flow for supply air and up, down, front and back
for return air to meet the different needs of equipment room. All units can be
easily maintained from the front.
Direct expansion air-cooled (DXA) work with CME or AMAE air-cooled
condenser.
Direct expansion water-cooled (DXW) work with CMEH dry cooler or central
cooling tower and pumping group.
Model 16E1A1 20E1A1 26E1A2 30E1A2 35E1A2 40E2A3 50E2A3 60E2A4 70E2A4 80E2A4 90E2A5 100E2A5
Supply air scheme O:Up flow; U:Down flow
Power source 380V-3Ph-50Hz
Cooling capacity
DXA(1) kW 18.9 22.0 28.5 31.9 37.6 46.6 55.1 65.3 74.5 84.6 90.7 103.4
DXW(2) kW 17.6 21.5 27.9 31.2 36.1 45.8 57.2 62.1 72.2 82.3 90.4 106.7
Compressor Hermetic Scroll Type
Supply fan
Type EC Centrifugal Fan
Qty. of fan n. 1 1 1 1 1 2 2 3 3 3 3 3
Air volume m3/h 5750 6320 8900 9600 9600 12600 13600 17800 19200 21000 24600 27900
Electric heater capacity kW 6 6 9 9 9 13.5 13.5 18 18 18 18 18
Humidification capacity Kg/h 3 3 5 5 5 8 8 8 8 8 8 8
Air cooled
condenser(DXA)
CME5*1 CME8*1 CME10*1 CME10* CME15*1 CME8*2 CME10*2 CME10*2 CME15*2 CME15*2 CME20*2 CME20*2
Width*Depth*Height mm 875*890*1960 1480*890*1960 1750*890*1960 2490*890*1960 3095*890*2050
DXA Weight Kg 310 360 370 410 415 620 670 930 980 1020 1210 1250
DXW Weight Kg 322 374 385 423 431 656 709 971 1013 1076 1256 1300
(1) Return air dry bulb temperature 24℃,RH50%,Outdoor dry bulb temperature35℃;		
(2) Return air dry bulb temperature 24℃,RH50%,inlet condensing water temperature 30℃, standard water flow.
10
OPTIMA.CW/CWD
Model 20A1 30A1 40A2 45A2 55A3 65A3 80A4 100A4 120A5 140A5
Supply air scheme O:Up flow; U:Down flow
Power source 380V-3Ph-50Hz
Cooling capacity(1) kW 24.8 30.3 40.8 47.7 55.8 66.5 80.5 100.2 112.1 134.5
Supply fan
Type EC Centrifugal Fan
Qty. of fan n. 1 1 1 1 2 2 3 3 3 3
Air volume m3/h 6750 6750 9600 9600 15300 15300 21600 21600 28900 28900
Electric heater capacity kW 6 6 9 9 13.5 13.5 18 18 18 18
Humidification capacity Kg/h 3 3 5 5 8 8 8 8 8 8
Width*Depth*Height mm 875*890*1960 1480*890*1960 1750*890*1960 2490*890*1960 3095*890*2050
CW Weight Kg 310 335 380 410 470 510 550 575 660 690
CWD Weight Kg 327 356 408 448 504 556 600 642 730 785
(1) Return air dry bulb temperature 24℃,RH50%,inlet/outlet chilled water temperature 7℃/12℃.
Model 16E1A1 22E1A2 30E1A2 35E2A3 45E2A3 55E2A3 60E2A4 70E2A4 80E2A4 90E2A5 110E2A5
Supply air scheme O:Up flow; U:Down flow
Power source 380V-3Ph-50Hz
Cooling capacity
DXA(1) kW 16.3 22.3 30.2 36.9 47.2 55.2 61.6 70.8 80.3 92.3 112.8
DXW(2) kW 17.2 23.5 32.1 36.8 48.1 56.4 63.5 73.5 82.3 93.7 115.4
Compressor Hermetic DC Inverter Scroll Type
Supply fan
Type EC Centrifugal Fan
Qty. of fan 1 1 1 2 2 2 3 3 3 3 3
Air volume 5750 8900 9600 12600 12600 13600 17800 19200 21000 24600 27900
Electric heater capacity n. 6 9 9 13.5 13.5 13.5 18 18 18 18 18
Humidification capacity Kg/h 3 5 5 8 8 8 8 8 8 8 8
Air cooled
condenser(DXA)
Model*n. AMAE6*1 AMAE8*1 AMAE10*1 AMAE6*2 AMAE8*2 AMAE8*2 AMAE10*2 AMAE12*2 AMAE15*2 AMAE18*2 AMAE20*2
Dry cooler(DXW) Model*n. CMEH20*1 CMEH30*1 CMEH40*1 CMEH50*1 CMEH60*1 CMEH70*1 CMEH80*1 CMEH50*2 CMEH50*2 CMEH60*2 CMEH70*2
Width*Depth*Height mm 875*890*1960 1480*890*1960 1750*890*1960 2490*890*1960 3095*890*2050
DXA Weight Kg 348 440 475 710 750 790 960 1010 1150 1270 1350
DXW Weight Kg 395 490 510 750 810 860 1080 1130 1250 1430 1540
(1) Return air dry bulb temperature 24℃,RH50%,outdoor dry bulb temperature35℃, variable speed compressor is operating at
economicspeed;
(2) Return air dry bulb temperature 24℃,RH50%, inlet condensing water temperature 30℃, water flow under standard condition, variable
speed compressor is operating at economic speed .
OPTIMA-INV.DXA/DXW
11
OPTIMA-FC/OPTIMA-FC-INV
OPTIMA-FC precision air conditioner integrated with free cooling for critical
application,including standard series of OPTIMA-FC and DC inverter series
of OPTIMA-FC-INV, is applicable to large and medium-sized data center
and electronic equipment room. It has a wide range cooling capacity, high
operating reliability and stability. Equipped with EC fan, precise control of
temperature±1℃, relative humidity ±5% which can assure the reliable and
stable environment of the data room.For double cooling source version, the
unit can provide cooling by either chilled water or direct expansion cooling,
providing higher reliability and flexibility for efficient operation. Free Cooling
version can greatly reduce the energy consumption and cut the energy bill.
OPTIMA-FC/OPTIMA-FC-INV has two direct expansion cooling type, air-
cooled and water-cooled. There are two schemes of supply air--up supply
and down supply can be provide to different needs of equipment room. Easily
maintain from the front of the product.
OPTIMA-FC/OPTIMA-FC-INV has three working mode:mechanical cooling,
partial free cooling and free cooling only.
OPTIMA-FC/OPTIMA-FC-INV series double cooling source version has three
working mode, mechanical cooling, chilled water cooling and double cooling
source.
Direct expansion air-cooled (DXA) work with CME or AMAE condenser.
Direct expansion water-cooled (DXW) work with CMEH dry cooler or central
cooling tower and pumping group.
Chilled water coil work with chiller plant, central cooling tower or CMEH dry
cooler and pumping group.
OPTIMA-FC.DXA/DXW
Model 16E1A1 20E1A1 26E1A2 30E1A2 35E1A2 40E2A3 50E2A3 60E2A4 70E2A4 80E2A4 90E2A5 100E2A5
Supply air scheme O:Up flow; U:Down flow
Power source 380V-3Ph-50Hz
Cooling capacity
DXA(1) kW 18.9 22 28.5 31.9 37.6 46.6 55.1 65.3 74.5 84.6 90.7 103.4
DXW(2) kW 17.6 21.5 27.9 31.2 36.1 45.8 57.2 62.1 72.2 82.3 90.4 106.7
Free cooling capacity(3)
DXA kW 16.5 21.8 30.1 33.6 37.6 42.4 50.3 55.9 67.3 78.5 93.4 104.6
DXW kW 16.5 21.8 30.1 33.6 37.6 42.4 50.3 55.9 67.3 78.5 93.4 104.6
Compressor Hermetic Scroll Type
Supply fan
Type EC Centrifugal Fan
Qty. of fan n. 1 1 1 1 1 2 2 3 3 3 3 3
Air volume m3/h 5750 6320 8900 9600 9600 12600 13600 17800 19200 21000 24600 27900
Electric heater capacity kW 6 6 9 9 9 13.5 13.5 18 18 18 18 18
Humidification capacity Kg/h 3 3 5 5 5 8 8 8 8 8 8 8
Air cooled condenser(DXA) Model*n. CME5*1 CME8*1 CME10*1 CME10* CME15*1 CME8*2 CME10*2 CME10*2 CME15*2 CME15*2 CME20*2 CME20*2
Dry cooler(DXA) Model*n. CMEH20*1 CMEH30*1 CMEH40*1 CMEH40*1 CMEH50*1 CMEH50*1 CMEH60*1 CMEH60*1 CMEH70*1 CMEH80*1 CMEH50*2 CMEH60*2
Dry cooler(DXW) Model*n. CMEH20*1 CMEH30*1 CMEH40*1 CMEH40*1 CMEH50*1 CMEH60*1 CMEH70*1 CMEH80*1 CMEH50*2 CMEH50*2 CMEH60*2 CMEH70*2
Width*Depth*Height mm 875*890*1960 1480*890*1960 1750*890*1960 2490*890*1960 3095*890*2050
DXA Weight Kg 315 366 375 413 420 630 680 940 980 1040 1230 1270
DXW Weight Kg 348 405 423 464 476 708 770 1037 1085 1157 1338 1392
(1) Return air dry bulb temperature 24℃,RH50%,Outdoor dry bulb temperature35℃;
(2) Return air dry bulb temperature 24℃,RH50%,inlet chilling water temperature 30℃, standard chilling water flow under standard condition;
(3) Return air dry bulb temperature 24℃,RH50%,Outdoor temperature 2℃, standard chilling water flow under standard condition.
12
OPTIMA-FC-INV.DXA/DXW
Model 16E1A1 22E1A2 30E1A2 35E2A3 45E2A3 55E2A3 60E2A4 70E2A4 80E2A4 90E2A5 110E2A5
Supply air scheme O:Up flow; U:Down flow
Power source 380V-3Ph-50Hz
Cooling capacity
DXA(1) kW 16.1 22.2 30.1 35.5 46.7 55.2 61.2 70.3 80.1 91.5 111.9
DXW(2) kW 17.2 23.5 32.1 36.8 48.1 56.4 63.5 73.5 82.3 93.7 115.4
Free cooling capacity(3)
DXA(3) kW 17.1 23.5 34.5 37.8 41.7 57.1 63.6 75.3 84.4 93.4 114.6
DXW(3) kW 17.1 23.5 34.5 37.8 41.7 57.1 63.6 75.3 84.4 93.4 114.6
Compressor Hermetic DC Inverter Scroll Type
Supply fan
Type EC Centrifugal Fan
Qty. of fan n. 1 1 1 2 2 2 3 3 3 3 3
Air volume m3/h 5750 8900 9600 12600 12600 13600 17800 19200 21000 24600 27900
Electric heater capacity kW 6 9 9 13.5 13.5 13.5 18 18 18 18 18
Humidification capacity Kg/h 3 5 5 8 8 8 8 8 8 8 8
Air cooled condenser(DXA) Model*n. AMAE6*1 AMAE8*1 AMAE10*1 AMAE6*2 AMAE8*2 AMAE8*2 AMAE10*2 AMAE12*2 AMAE15*2 AMAE18*2 AMAE20*2
Dry cooler(DXA) Model*n. CMEH20*1 CMEH30*1 CMEH40*1 CMEH50*1 CMEH60*1 CMEH70*1 CMEH80*1 CMEH50*2 CMEH50*2 CMEH60*2 CMEH70*2
Dry cooler(DXW) Model*n. CMEH20*1 CMEH30*1 CMEH40*1 CMEH50*1 CMEH60*1 CMEH70*1 CMEH80*1 CMEH50*2 CMEH50*2 CMEH60*2 CMEH70*2
Width*Depth*Height mm 875*890*1960 1480*890*1960 1750*890*1960 2490*890*1960 3095*890*2050
DXA Weight Kg 375 490 510 750 790 830 1080 1130 1220 1420 1510
DXW Weight Kg 405 520 540 790 830 875 1120 1160 1280 1470 1590
(1) Return air dry bulb temperature 24℃,RH50%,outdoor dry bulb temperature35℃, variable speed compressor is operating at economic speed;
(2) Return air dry bulb temperature 24℃,RH50%,inlet chilling water temperature 30℃, chilling water flow under standard condition, variable
speed compressor is operating at economic speed;
(3) Return air dry bulb temperature 24℃,RH50%,outdoor temperature 2℃, chilling water flow under standard condition.
13
OPTIMA-HD
OPTIMA-HD is one type of precision air conditioners with high density
cooling capacity by using chilled water, applicable to large and medium-
sized data center and electronic equipment room. It has a wide range
cooling capacity, high operating reliability and stability, the density of cooling
capacity is up to 75kW/m2
which can save a lot of space in equipment room.
Equipped with EC fan, OPTIMA-HD has a high operating efficiency, precise
control of temperature +/- 1℃, relative humidity +/-5% which can assure the
reliable and stable environment of the data room.
There are three air flow schemes, up flow, down flow and front flow under
rise floor can be provide to different needs of equipment room. Easily
maintain from the front of the product.
OPTIMA-HD use chilled water as cooling resource for mechanical cooling or
free cooling. The system has the characteristics of simple structure, reliable
and save the operating expense .
OPTIMA-HD has two types: single circuit and dual circuits. Each circuit
of dual circuits can be redundancy each other or work simultaneously or
rotation between mechanical cooling and chilled water of free cooling.
(1) Return air dry bulb temperature 24℃,RH50%,inlet/outlet chilled water temperature 7℃/12℃;
(2) Excluding the height of return air plenum of up flow unit and supply air plenum of down flow unit.
Model 40B1 60B1 80B2 100B2 120B3 140B3 160B4 180B4 50D1 60D1 80D2 100D2 120D3 140D3
Circuit CW: single circuit CWD: double circuit
Supply air scheme O:Up flow; U:Down flow U:Down flow
Power source 380V-3Ph-50Hz 380V-3Ph-50Hz
Cooling capacity(1) kW 42.1 60.7 83.6 101.6 123.3 145.2 160.5 180.9 50.4 61.1 81.0 100.7 120.5 143.2
Water flow(1) m3/h 7.2 9.6 14.2 17.3 19.5 24.7 26.3 28.4 7.7 9.6 12.7 14.8 17.9 22.0
Water pressure drop(1) kPa 95 97 86 94 93.6 91.2 98.6 83.9 101.1 123.1 83.1 83.2 184.6 156.6
Supply fan
Type EC Centrifugal Fan EC Centrifugal Fan
Qty. of fan n. 1 1 2 2 3 3 3 3 1 1 2 2 3 3
Air volume m3/h 11700 12600 22600 23600 31800 32600 37200 37200 11600 12300 23600 22800 31200 33600
Electric heater capacity kW 9 9 13.5 13.5 18 18 18 18 9 9 13.5 13.5 13.5 13.5
Humidification capacity Kg/h 8 8 8 8 8 8 8 8 8 8 8 8 8 8
Width*Depth*Height(O/U)(2) mm 900*900*1960/1730 1750*900*1960/1730 2490*900*1960/1730 2905*900*1960/1730 1250*900*1900 1750*900*1900 2560*900*1900
Weight Kg 375 405 525 560 670 750 840 910 380 405 465 490 580 640
14
DATACOOL Precision air conditioning units are widely applied in small/medium
data center and computer rooms. DADATCOOL unit adopts new technologies,
using efficient compressor and fans and optimizing refrigerating system
configuration, to achieve its high efficiency and reliability, realizing COP >2.9,
temperature control accuracy <±1℃ while humidity control accuracy <±5%.
The compact structure and light weight makes easy installation. The unit can be
fully maintained from the front, greatly reducing the maintenance cost.
DATACOOL unit is available in 4 different air flow scheme: front up flow, down flow,
displacement flow, top flow, offering more options for different customers.
DATACOOL
(1) Return air dry bulb temperature 24℃,RH50%,Outdoor dry bulb temperature35℃.
Model 5E1C0 7E1C0 13E1C0 7E1C1 10E1C1 13E1C1 15E1C2 18E1C2 22E1C3 25E1C3 30E1C3
Supply air scheme O: up-front throw O: up-front throw; U: Bottom Throw; DL: Replacement; TP: top throw
Power source 380V-3Ph-50Hz
Cooling capacity(1) 5.8 7.4 13.2 7.6 10.7 13.6 15.4 18.3 22.2 25.4 30.2
Compressor Rotor Hermetic Scroll
Supply fan
Qty. of fan n. 1 1 1 1 1 1 1 1 2 2 2
Air volume m3/h 1650 1650 2630 2450 2450 2950 3450 3450 5100 6500 6500
Electric heater capacity kW 2.3 2.3 4.5 2.3 4.5 4.5 6 6 9 9 9
Humidification capacity Kg/h 3 3 3 3 3 3 5 5 5 8 8
Air cooled condenser CMD3*1 CMD4*1 CMD5*1 CMD4*1 CMD4*1 CMD5*1 CME5*1 CME8*1 CME8*1 CME10*1 CME10*1
Width*Depth*Height mm 650*580*1910 650*650*1910 900*750*1910 1300*750*1910
Weight Kg 120 135 155 142 165 180 255 290 370 460 490
DATACOOL-PACKAGE air conditioner with built-in fresh air free cooling system
is specially designed for small/medium data center and electronic equipment
room. Due to its proper working logic and standard EC supply fan, DATACOOL-
PACKAGE can maximum works in free cooling mode with the lowest power
consumption, saving huge energy and lowering the operation cost.
DATACOOL-PACKAGE is a self-contained air conditioning unit which realizes
easy installation without any refrigeration piping connection. The unit can be fully
maintained from the front, greatly reducing the maintenance cost as well.
DATACOOL-PACKAG is available in 2 different air flow schemes: up flow and down
flow, offering more options for different customers to increase its application flexibility.
DATACOOL-PACKAGE
(1) Return air dry bulb temperature 24℃,RH50%,Outdoor dry bulb temperature35℃;
(2) Indoor temperature and outdoor temperature difference (ΔT) is 10℃.
Model 8E1A1 15E1A1 22E1A2 30E2A2 45E2A3
Supply air scheme O:Up flow; U:Down flow
Power source 380V-3Ph-50Hz
Cooling capacity(1) kW 9.1 16.5 23.9 33 48.6
Free cooling capacity(2) kW 13.1 18.5 25 27.5 50
Compressor Hermetic Scroll Type
Evaporator fan
Type EC Centrifugal Fan
Qty. of fan n. 1 1 1 1 2
Air volume m3/h 4350 6150 8320 9150 16640
Condenser fan
Type EC Centrifugal Fan
Qty. of fan n. 1 1 1 2 4
Air volume m3/h 4200 5100 5800 10200 14400
Electric heater capacity kW 4.5 4.5 4.5 6 9
Width*Depth*Height(packaged unit) mm 1160*1050*2350 1460*1100*2350 2920*1100*2350
Width*Depth*Height(split unit) 1160*1050*2450 1460*1100*2450 2920*1100*2450
Weight (packaged unit) Kg 450 520 610 660 1280
Weight (split unit) Kg 500 570 680 730 1420
15
MOBILECOOL-OUTDOOR
MOBILECOOL-OUTDOOR is a package type telecommunication base station
special air conditioner and designed for telecommunication base station, small
electronic equipment room. The unit features including good structure, easy
maintenance, high sensible ratio, high efficiency, and high reliability. The air
supplied from the front lower portion of the unit, which conforms with the air
flow rules well, making the heat exchange more efficiency.
MOBILECOOL-OUTDOOR uses EC fan supplied with alternating current
(direct current is optional). The unit is available in single or dual-control,
supplying various running strategies. The free cooling function is standard
configuration, saving the energy consumption highly.
MOBILECOOL-OUTDOOR installed in the outside of the shelter. The
installation type can save the space of shelters.
Model 3R1C1 5E1C1 7E1C2 10E1C2 13E1C3 18E1C4 7E1C2 10E1C2 13E1C3 18E1C4
Supply air scheme DL:Replacement DL:Replacement
Power source 230V-1Ph-60Hz 230V-3Ph-60Hz
Cooling capacity(1) kW 3.5 5 8.1 10 13.4 17.8 8.1 10 13.4 17.8
Free cooling capacity(2) kW 3.4 4.0 7.1 8.2 8.9 12.9 7.1 8.2 8.9 12.9
Compressor Rotory Scroll Scroll
Evaporator fan
Type EC Centrifugal Fan EC Centrifugal Fan
Air volume m3/h 1000 1200 2120 2460 2650 3850 2120 2460 2650 3850
Condenser fan
Type Axial Axial
Air volume m3/h 3400 3400 5000 6300 6300 8200 5000 6300 6300 8200
Width*Depth*Height mm 620*620*1930 930*700*2139 1080*700*2139 1280*700*2139 930*700*2139 1080*700*2139 1280*700*2139
Weight Kg 135 145 235 240 280 320 235 240 280 320
Model 3R1C1 5E1C1 7E1C2 10E1C2 13E1C3 18E1C4 5E1C1 7E1C2 10E1C2 13E1C3 18E1C4
Supply air scheme DL:Replacement DL:Replacement
Power source 220V-1Ph-50Hz 380V-3Ph-50Hz
Cooling capacity(1) kW 3.5 5.2 7.5 10.8 13.4 17.5 5.2 7.5 10.8 13.4 17.9
Free cooling capacity(2) kW 3.4 4.0 7.1 8.2 8.9 12.9 4.0 7.1 8.2 8.9 12.9
Compressor Rotory Scroll Scroll
Evaporator fan
Type EC Centrifugal Fan EC Centrifugal Fan
Air volume m3/h 1000 1200 2120 2460 2650 3850 1200 2120 2460 2650 3850
Condenser fan
Type Axial Axial
Air volume m3/h 3200 3200 4200 5800 5800 7500 3200 4200 5800 5800 7500
Width*Depth*Height mm 620*620*1930 930*700*2139 1080*700*2139 1280*700*2139 620*620*1930 930*700*2139 1080*700*2139 1280*700*2139
Weight Kg 135 145 235 240 280 320 145 235 240 280 320
(1) Return air dry bulb temperature 27℃、RH50%,Outdoor dry bulb temperature35℃;
(2) Indoor temperature and outdoor temperature difference (ΔT) is 10℃.
16
MOBILECOOL-INDOOR
MOBILECOOL-INDOOR is a package type telecommunication base station
special air conditioner and designed for telecommunication base station,
small electronic equipment room. The unit features including good structure,
easy maintenance, high sensible ratio, high efficiency, and high reliability.
The air supplied from the front lower portion of the unit, which conforms with
the air flow rules well, making the heat exchange more efficiency.
MOBILECOOL-INDOOR uses EC fan supplied with alternating current
(direct current is optional). The unit is available in single or dual-control,
supplying various running strategies. The free cooling function is standard
configuration, saving the energy consumption highly.
MOBILECOOL-INDOOR installed in the inside of the shelter. The installation
type is anti-theft, protecting the air conditioner from bad environment.
(1) Return air dry bulb temperature 27℃,RH50%,Outdoor dry bulb temperature35℃;
(2) Indoor temperature and outdoor temperature difference (ΔT) is 10℃.
Model 3R1D0 5E1D1 7E1D2 10E1D3 13E1D4 7E1D2 10E1D3 13E1D4
Supply air scheme DL:Replacement DL:Replacement
Power source 230V-1Ph-60Hz 230V-3Ph-60Hz
Cooling capacity(1) kW 3.4 5 7.9 9.8 13.2 7.9 9.8 13.2
Free cooling
capacity(2)
kW 3.4 4.0 7.1 8.2 8.9 7.1 8.2 8.9
Compressor Rotory Scroll Scroll
Evaporator fan
Type EC Centrifugal Fan EC Centrifugal Fan
Air volume m3/h 1000 1200 2120 2460 2650 2120 2460 2650
Condenser fan
Type Centrifugal Fan Centrifugal Fan
Air volume m3/h 2400 2800 2800 4200 5600 2800 4200 5600
Width*Depth*Height mm 500*600*2000 600*600*2000 750*650*2100 860*650*2100 1010*650*2100 750*650*2100 860*650*2100 1010*650*2100
Weight Kg 130 160 200 255 290 200 255 290
Model 3R1D0 5E1D1 7E1D2 10E1D3 13E1D4 5E1D1 7E1D2 10E1D3 13E1D4
Supply air scheme DL:Replacement DL:Replacement
Power source 220V-1Ph-50Hz 380V-3Ph-50Hz
Cooling capacity(1) kW 3.4 5.2 7.4 10.6 13.3 5.2 7.4 10.6 13.3
Free cooling
capacity(2)
kW 3.4 4.0 7.1 8.2 8.9 4.0 7.1 8.2 8.9
Compressor Rotory Scroll Scroll
Evaporator fan
Type EC Centrifugal Fan EC Centrifugal Fan
Air volume m3/h 1000 1200 2120 2460 2650 1200 2120 2460 2650
Condenser fan
Type Centrifugal Fan Centrifugal Fan
Air volume m3/h 2400 2800 2800 4200 5600 2800 2800 4200 5600
Width*Depth*Height mm 500*600*2000 600*600*2000 750*650*2100 860*650*2100 1010*650*2100 600*600*2000 750*650*2100 860*650*2100 1010*650*2100
Weight Kg 130 160 200 255 290 160 200 255 290
17
MOBILECOOL-SPLIT
MOBILECOOL-SPLIT is a spilt type telecommunication base station special air
conditioner and designed for telecommunication base station, small electronic
equipment room. The unit features including good structure, easy maintenance,
high sensible ratio, high efficiency, and high reliability. The air supplied from the
front lower portion of the unit, which conforms with the air flow rules well, making
the heat exchange more efficiency.
MOBILECOOL-SPLIT uses AC fan supplied with alternating current (direct
current is optional). The unit is available in single or dual-control, supplying
various running strategies. The free cooling function is optional, saving the
energy consumption highly.
Model 5R1D1 7R1D1 10E1D2 13E1D2 15E1D2
Supply air scheme O:Up flow; DL: Replacement
Power source 220V-1Ph-50Hz 380V-3Ph-50Hz
Cooling capacity(1) kW 5.5 7.6 10.4 13.3 14.9
Free cooling capacity(2) kW 5.9 5.9 7.4 11.6 11.6
Compressor Hermetic Rotary Type Hermetic Scroll Type
Supply fan
Type AC Centrifugal Fan
Air volume m3/h 1800 1800 2250 3500 3500
Width*Depth*Height mm 600*500*1700 600*500*1700 750*500*1700 750*500*1700 750*500*1700
Weight kg 70 80 150 160 165
Condenser unit
Model CMD3 CMD4 CMD4 CMD5 CMD6
Width*Depth*Height mm 808*509*789 808*509*789 808*509*789 1004*509*930 1250*509*930
Weight kg 29 35 35 43 92
(1) Return air dry bulb temperature 27℃,RH50%,Outdoor dry bulb temperature35℃;
(2) Indoor temperature and outdoor temperature difference (ΔT) is 10℃(only for DL air supply scheme unit).
18
METROCOOL
METROCOOL unit is specially designed for industry environment, standing
up to high temperature, heavy pollution and continuous working demand and
offering high efficiency, strict fire proofing, various power supplies and widely
working condition with high reliability.
METROCOOL is a split air conditioning unit with rational structure for
convenient maintenance.
Electrical heaters with different capacity are available for this unit as options
to satisfy different application requirement.
Model MTC.5 MTC.7 MTC.10 MTC.13 MTC.5 MTC.7 MTC.10 MTC.13 MTC.5 MTC.7 MTC.10 MTC.13
Power source 380V-3Ph-50Hz 220V-1Ph-50Hz 208~230V-1Ph-60Hz
Cooling capacity(1) kW 5.2 7.3 10.0 13.0 5.2 7.3 10.0 13.0 5.0 6.8 10.7 13.0
Unit max. operating power input kW 3.2 3.9 5.3 6.5 3.4 4.0 5.5 6.5 2.9 3.8 5.3 6.8
Unit max. operating current A 8.0 9.5 12.2 16.5 14.7 18.9 27.0 24.6 13.1 16.6 24.8 31.2
Indoor unit
Fan type Double Inlet Centrifugal Fan Double inlet Centrifugal Fan Double inlet Centrifugal Fan
Air volume m3/h 1400 1400 1600 2000 1400 1400 1600 2000 1400 1400 1600 2000
Width*Depth*Height mm 1295*280*680 1295*310*870 1295*280*680 1295*310*870 1295*280*680 1295*310*870
Weight Kg 52 54 64 67 52 54 64 67 52 54 64 67
Outdoor unit
Compressor Hermetic scroll type Hermetic scroll type Hermetic scroll type
Fan type Axial flow fan Axial flow fan Axial flow fan
Width*Depth*Height mm 1260*590*880 1440*590*1125 1305*590*1500 1260*590*880 1440*590*1125 1305*590*1500 1260*590*880 1440*590*1125 1305*590*1500
Weight Kg 91 95 123 145 91 95 123 145 91 95 123 145
Piping connection
Condensing water drainage mm 16 16 16 16 16 16 16 16 16 16 16 16
Refrigerant liquid in 3/8″ 1/2″ 1/2″ 1/2″ 1/2″ 1/2″ 1/2″ 1/2″ 1/2″ 1/2″ 1/2″ 1/2″
Refrigerant gas in 1/2″ 5/8″ 3/4″ 3/4″ 5/8″ 5/8″ 3/4″ 3/4″ 5/8″ 5/8″ 3/4″ 3/4″
(1) Top grade air flow, return air dry bulb temperature 27℃,wet bulb temperature 19℃,outdoor dry bulb temperature35℃, wet bulb temperature 24℃.
19
TELECOOL
Cabinet air condition is actively cooling with compressor, and it will remove the
heat inside the cabinet to outside. It also can keep the dust and heat outside the
cabinet, avoiding problems from using fan. The inside cabinet can be maintained
at an ideal temperature for electrical components which effectively guarantees
the stability of the electronic equipment and improves the reliability of the whole
system. The products can be widely used for outdoor communication cabinets,
battery cabinets, electric cabinets, industry control cabinets etc.
(1) Return air dry bulb temperature 35℃,outdoor dry bulb temperature35℃.
(1) Return air dry bulb temperature 35℃,outdoor dry bulb temperature35℃.
Model TC.AC.300 TC.AC.400 TC.AC.600 TC.AC.800 TC.AC.1000 TC.AC.1200 TC.AC.1500 TC.AC.2000 TC.AC.2500 TC.AC.3000
Cooling Capacity(L35/L35) W 300 400 600 800 1000 1200 1500 2000 2500 3000
Rated Power W 220 240 365 460 490 610 685 830 1020 1240
Working Voltage 220VAC±15% 50/60Hz
Working Temperature -40~55℃
Refrigerant R134a R134a/R22
Noise dB 55 55 56 58 60 62 64 68 68 70
Ambient Air Circuit m3/h 280 280 450 450 540 580 780 950 1150 1380
Cabinet Air Circuit m3/h 160 160 200 230 250 360 450 560 640 780
Width*Depth*Height(R134a) mm 353*165*583 455*155*692 482*187*781 497*188*897 460*188*1087 549*220*1208 569*220*1308
Width*Depth*Height(R22) mm / 482*187*781 497*188*897 460*188*1087 549*220*1208
Model TC.DC.400 TC.DC1000 TC.DC.2000 TC.DC.3000
Cooling Capacity(L35/L35) W 400~600 800~1000 1500~2000 2500~3000
Rated Power W 240 450 725 1120
Working Voltage DC 48V
Working Temperature -40~55℃
Refrigerant R134a
Noise dB 55 60 64 68
Ambient Air Circuit m³/h 450 540 780 1380
Cabinet Air Circuit m³/h 200 250 450 780
Width*Depth*Height mm 455*155*692 482*187*781 497*188*897 549*220*1208
20
FREECOOL-HD
FREECOOL-HD intelligent ventilation unit is applied in small/medium data center
and electronic equipment room. The unit introduces outdoor fresh air with lower
temperature to cool equipment room.
By using the FREECOOL-HD unit, the running hours of other air conditioning units
can be highly reduced, achieving power energy saving around 30~90%.
The FREECOOL-HD unit using EC fans can adjust the air volume automatically
according to the temperature difference with the lowest power consumption.
FREECOOL-HD without refrigeration system realizes easy installation and
convenient maintenance. The unit is available in 2 different air flow schemes: up
flow and down flow, and 2 installation positions: outdoor and indoor, offering more
options for different customers.
Model 24F1 48F2 72F1 144F2 216F3
Supply air scheme O/U
Air volume m3
/h 2400 4750 7200 14400 21600
Air volume m3
/s 0.67 1.3 2.0 4.0 6.0
Cooling capacity
△t=5℃ kW 4.0 7.9 12.0 24.0 36.0
△t=10℃ kW 8.0 15.8 24.0 48.0 72.0
△t=12℃ kW 9.6 19 28.8 57.6 86.4
Power source 230V/1/(50/60Hz) 400V/3/(50/60Hz)
Fan
Type Single inlet backward curved centrifugal fan
Qty. of fan n. 1 2 1 2 3
Input power kW 0.5 1.0 2.1 4.2 6.3
Current A 3.1 6.1 3.2 6.4 9.4
Width*Depth*Heigh mm 700*450*1320 1150*450*1320 850*800*1770 1650*800*1770 2450*800*1770
Weight kg 65 89 150 260 350
21
FREECOOL
FREECOOL intelligent ventilation unit is applied in shelters and small equipment
room. The unit introduces outdoor fresh air with lower temperature to cool
equipment room. By using the FREECOOL unit, the running hours of other air
conditioning units can be highly reduced, achieving power energy saving around
30~90%.The FREECOOL DC series using EC fans can adjust the air volume
automatically according to the temperature difference with the lowest power
consumption.
FREECOOL is able to control up to 2 air conditioners. The unit is available in
various installation positions: outdoor and indoor, packaged and split, offering
more options for different data centre.
Model 12F1 18F1 24F1 30F2 35F2 12F1 18F1 24F1 30F1 35F1
Structure type ID/OD Package ID/OD Split
Cooling capacity
△t=5℃ kW 1.7 2.4 3.4 4.4 5 1.7 2.9 3.4 5 5.7
△t=10℃ kW 3.1 4.8 6.8 8.7 9.9 3.3 5.8 6.8 10 11.4
△t=12℃ kW 3.8 5.7 8.1 10.5 11.9 4 6.9 8.1 12 13.7
Power source 48VDC;220VAC (Only available for ID installation unit) 48VDC;220VAC (Only available for ID installation unit)
Fan
Type Single inlet backward curved centrifugal fan Single inlet backward curved centrifugal fan
Qty. of fan n. 1 1 1 2 2 1 1 1 1 1
Air volume m3/h 1000 1450 2050 2650 3000 1000 1750 2050 3030 3450
Input power(48VDC) kW 0.06 0.19 0.22 0.3 0.4 0.06 0.19 0.23 0.26 0.39
Input power(220VAC) kW 0.13 0.18 0.39 0.36 0.5 0.13 0.18 0.39 0.38 0.57
Width*Depth*Height(ID) mm 650*500*1100 750*600*1400 550*450*700 600*500*900
Width*Depth*Height(OD) mm 650*500*1320 750*630*1620 550*550*600 610*610*630
Weight(ID) Kg 60 60 65 85 85 40 40 42 48 50
Weight(OD) Kg 65 65 68 115 115 38 38 40 45 45
22
Outdoor condenser and dry cooler
The covers of CME air-cooled condenser are produced by aluminum sheet,
which has characteristics of light weight, Anti-corrosion, anti-rust, etc. The
condenser is equipped with adjustable speed axial fan and high efficiency
heater exchanger. Vertical or horizontal installation of the condenser is
available.
The covers of AMAE air-cooled condenser are produced by aluminum sheet,
which has characteristics of light weight, anti-corrosion, anti-rust, etc. The
condenser is equipped with EC axial fan which has characteristics of big
air volume, lower power consumption and adjustable fan speed and high
efficiency heater exchanger. The condenser is suitable for high temperature
working conditions. Vertical or horizontal installation of the condenser is
available.
CMD air-cooled condenser is used for small precision air conditioner or
base station air conditioner. The covers of CMD condenser are produced
by coating sheet metal, which has characteristics of anti-corrosion, anti-rust,
etc. The condenser is equipped with adjustable speed axial fan and high
efficiency heater exchanger. Only vertical installation of the condenser is
available.
The covers of CMEH dry cooler are produced by aluminum sheet, which has
characteristics of light weight, Anti-corrosion, anti-rust, etc. The condenser
is equipped with adjustable speed axial fan and high efficiency heater
exchanger. Vertical or horizontal installation of the condenser is available.
CMD/CME
(1) Heat dissipating capacity @ inlet air temperature 35℃, condensation temperature 50℃.
Model CMD3 CMD4 CMD5 CMD6 CME4 CME5 CME8 CME10 CME15 CME20 CME25
Power source 220V-1Ph-50Hz
Capacity (1) kW 9.3 13.7 20.4 23.6 15.6 20.5 29.6 35.4 47.6 67.4 73.1
Fan
Qty. of fan n. 1 1 1 1 1 1 1 1 2 2 2
Air volume m3/h 4400 4100 5600 5800 4400 5600 10100 9700 11600 20100 19100
Input power kW 0.28 0.28 0.37 0.37 0.28 0.37 0.63 0.63 0.74 1.26 1.26
Input current A 1.3 1.3 1.7 1.7 1.3 1.7 3 3 3.4 6 6
Gas pipe ODF 5/8" 5/8" 5/8" 5/8" 16 19 22 22 22 28 35
Liquid pipe ODF 1/2" 1/2" 1/2" 1/2" 12 12 16 16 19 19 22
Width*Depth*Height mm 808*509*789 1004*509*930 1250*509*930 840*475*770 1140*475*770 1340*620*1070 1540*620*1070 2400*630*1135
Weight Kg 29 35 43 92 37 47 95 110 130 155 185
23
Model AMAE5 AMAE6 AMAE8 AMAE10 AMAE12 AMAE15 AMAE18 AMAE20
Power source 220V/1Ph/50Hz
Capacity (1) kW 24.2 29.7 36.2 41.3 50.7 57.2 62.4 74.3
Fan
Qty. of fan n. 1 1 1 1 2 2 2 2
Air volume m3/h 12500 11600 11800 11500 23500 22000 23400 22600
Input power kW 0.63 0.63 0.63 0.63 1.26 1.26 1.26 1.26
Input current A 2.8 2.8 2.8 2.8 5.6 5.6 5.6 5.6
Gas pipe ODF 19 19 19 22 22 22 22 28
Liquid pipe ODF 16 16 16 16 16 16 19 19
Width*Depth*Height mm 1365*620*1080 1665*620*1080 1985*620*1080 2790*620*1080
Weight Kg 103 116 135 152 173 182 206 220
AMAE
(1) Heat dissipating capacity @ inlet air temperature 35℃, condensation temperature 50℃.
(1) Heat dissipating capacity @ inlet air temperature 35℃, inlet water temperature 45℃.
Model CMEH20 CMEH30 CMEH40 CMEH50 CMEH60 CMEH70 CMEH80
Power source 220V/1Ph/50Hz
Capacity kW 23.2 31.2 45.3 56.7 61.5 75.2 83.1
Heat exchange coil
Water flow m3/h 3.5 5.2 6.2 9.3 10.2 10.6 11.8
Pressure drop kPa 71.1 68.2 58.7 57.6 69.1 72.3 78.5
Fan
Qty. of fan n. 1 1 2 2 2 3 3
Air volume m3/h 12100 11200 22800 23200 21800 33600 32400
Nominal mechanical power kW 0.75 0.75 1.5 1.5 1.5 2.3 2.3
Max electric absorption A 3.3 3.3 6.6 6.6 6.6 10.1 10.1
Width*Depth*Height mm 1350*620*1070 1980*620*1120 2700*620*1120 3580*620*1120
Weight Kg 95 115 145 175 195 235 255
CMEH
24
Standard
Compact type
CRITICOOL/CRITICOOL-FC
CRITICOOL series is applicable to large-sized data center and all kinds of
industrial technology place. It has a wide range cooling capacity, high operating
reliability and stability. CRITICOOL-FC is equipped with additional chilled water
coil, free cooling system will be used when outdoor temperature is low enough,
minimize the run time of mechanical cooling and save huge energy and lowering
the operation cost.
CRITICOOL adopts screw compressor, offer built-in pump group as option, the
customer only need to connect water pipe and power supply cable on the site.
Outdoor installation, no room occupied.
Model 130V1 150V1 200V1 250V1 350V1 400V1 450V1 500V1 400V2 450V2 700V2 800V2
Cooling capacity(1) kW 115 138 178 245 315 377 408 475 370 420 630 754
Heating capacity(2) kW 128.8 154.6 199.4 274.4 356 422.2 457 532 414.4 470.4 711.9 844.5
Qty of compressor n. 1 1 1 1 1 1 1 1 2 2 2 2
Heating capacity of partial heat
recycle(Option)(3)
kW 34 41 56.8 80.5 103.7 120.3 122.4 142.5 118 126 198 216.7
Length mm 3600 3600 4335 5170 4980 4980 4980 6490 4980 6490 7480 8470
Width mm 1290 1290 1290 1290 2130 2130 2130 2130 2130 2130 2130 2130
Height mm 2280 2280 2280 2280 2540 2540 2540 2540 2540 2540 2540 2540
Weight (4) kg 1640 1780 1910 2350 3425 3800 3880 4850 3960 4900 6250 7000
Model 700V2 750V2 800V2 890V2 950V2 1000V2 1100V2 1200V2 900V3 1000V4 1200V4 1400V4 1500V4 1600V4
Cooling capacity(1) kW 630 692 754 816 883 942 1033 1124 880 996 1126 1256 1390 1508
Heating capacity(2) kW 712 778 844 914 991 1066 - - 986 1118 1261 1407 1557 1689
Qty of compressor n. 2 2 2 2 2 2 2 2 3 4 4 4 4 4
Heating capacity of partial
heat recycle(Option)(3)
kW 189 207.6 226.2 244.8 264.9 282.6 309.9 337.2 264 320.4 396 396 448 481.2
Length mm 6450 6750 7050 7050 8130 9210 10290 11370 8710 10780 11340 12900 13500 14100
Width mm 2350 2350 2350 2350 2350 2350 2350 2350 2350 2350 2350 2350 2350 2350
Height mm 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600
Weight (4) kg 6760 7080 7400 7650 8190 9260 10280 11300 9520 11920 12740 13520 14160 14800
(1) Nominal cooling capacity @ outside DB is 35℃, chilled water outlet temperature 7℃, inlet temperature 12℃;
(2) Nominal heating capacity @ outside DB is 7℃, WB is 6℃; hot water outlet tempreature 45℃, inlet tempreature 40℃;
(3) The inlet temperature of heat recycle 40℃;
(4) Exclude the weight of option.
(1) Nominal cooling capacity @ outside DB is 35℃, chilled water outlet temperature 7℃, inlet temperature 12℃;
(2) Nominal heating capacity @ outside DB is 7℃, WB is 6℃; hot water outlet tempreature 45℃, inlet tempreature 40℃;
(3) The inlet temperature of heat recycle 40℃;
(4) Exclude the weight of option.
25
(1) Nominal cooling capacity @ outside DB is 35℃, chilled water outlet temperature 7℃, inlet temperature 12℃;
(2) Nominal heating capacity @ outside DB is 7℃, WB is 6℃; hot water outlet tempreature 45℃, inlet tempreature 40℃;
(3) The inlet temperature of heat recycle 40℃;
(4) Exclude the weight of option.
(1) Nominal cooling capacity @ outside DB is 35℃, chilled water outlet temperature 7℃, inlet temperature 12℃;
(2) Nominal heating capacity @ outside DB is 7℃, WB is 6℃; hot water outlet tempreature 45℃, inlet tempreature 40℃;
(3) The inlet temperature of heat recycle 40℃;
(4) Exclude the weight of option.
Standard free cooling type
Model  350V1 400V1 450V1 500V1 600V1 700V2 750V2
Cooling capacity(1) kW 312 373 404 470 557 624 685
Cooling capacity(2) kW 346 414 448 522 619 692 760
Free cooling capacity(3) kW 348 416 451 525 622 696 764
Qty. of compressors n. 1 1 1 1 1 2 2
Length mm 3410 3710 3710 4790 5870 6450 6750
Width mm 2350 2350 2350 2350 2350 2350 2350
Height mm 2600 2600 2600 2600 2600 2600 2600
Weight kg 3780 4140 4305 5130 6240 7560 7880
Model 800V2 890V2 950V2 1000V2 1200V2 1400V2 1600V2
Cooling capacity(1) kW 746 808 874 931 1115 1271 1493
Cooling capacity(2) kW 829 897 970 1034 1237 1411 1657
Free cooling capacity(3) kW 833 901 975 1039 1244 1418 1665
Qty. of compressors n. 2 2 2 2 2 2 2
Length mm 7050 7050 8130 9210 10290 11370 14100
Width mm 2350 2350 2350 2350 2350 2350 2350
Height mm 2600 2600 2600 2600 2600 2600 2600
Weight kg 8350 8590 9270 11320 13300 14100 16000
Low noise free cooling type
Model  130V1 150V1 200V1 250V1 350V1 400V1 450V1 500V1 600V1 700V1 800V1
Cooling capacity(1) kW 114 137 176 243 312 373 404 470 557 636 746
Cooling capacity(2) kW 126 152 196 269 346 414 448 522 619 705 829
Free cooling capacity(3) kW 127 152 197 271 348 416 451 525 622 709 833
Qty. of compressors n. 1 1 1 1 1 1 1 1 1 1 1
Length mm 3600 3600 4355 5170 4980 4980 4980 6490 7480 7480 8470
Width mm 1420 1420 1420 1420 2370 2370 2370 2370 2370 2370 2370
Height mm 2280 2280 2280 2280 2540 2540 2540 2540 2540 2540 2540
Weight kg 1840 1980 2210 2550 3725 4250 5400 5660 6650 7050 8000
Model  400V2 450V2 500V2 600V2 700V2 800V2 1000V2 1200V2 1400V2 1600V2
Cooling capacity(1) kW 366 416 497 557 624 746 941 1115 1271 1493
Cooling capacity(2) kW 407 462 552 619 692 829 1044 1237 1411 1657
Free cooling capacity(3) kW 409 464 554 622 696 833 1049 1244 1418 1665
Qty. of compressors n. 2 2 2 2 2 2 2 2 2 2
Length mm 4980 6490 6490 7480 7480 8470 13780 15760 15760 18440
Width mm 2370 2370 2370 2370 2370 2370 2370 2370 2370 2370
Height mm 2540 2540 2540 2540 2540 2540 2540 2540 2540 2540
Weight kg 4760 5900 6160 7260 7550 8500 11320 13300 14100 16000
26
HYDROCOOL
HYDRCOOL/HYDROCOO-HE series is applicable to large-sized data
center and all kinds of industrial technology place. It has a wide range
cooling capacity, high operating reliability and stability. HYDROCOO-HE
is equipped with flooded evaporator, to achieve higher EER, save huge
energy and lowering the operation cost.
This series adopts screw compressor and flooded evaporator, minimized
the unit size and footprint.
Standard
Full liquid Type
Model 250V1 400V1 500V1 600V1 700V1 500V2 800V2 900V2 1000V2 1100V2 1200V2 1300V2
Cooling capacity (1) kW 229.5 406.7 495.1 589.7 736.5 459 804.6 894.7 989.8 1076 1175.6 1320
Cooling capacity (2) kW 238.2 422.2 513.9 612.1 764.5 476.4 835.2 928.7 1027.4 1116.9 1220.3 1370.2
Heating capacity (3) kW 237.5 421.6 511.3 611 763 475 835.8 927.1 1021.6 1115.5 1218.7 1369.1
Qty of compressor n. 1 1 1 1 1 2 2 2 2 2 2 2
Heating capacity of
partial heat recycle
kw 52.9 86.1 104.1 134.1 160 103.9 172.5 192.1 209.4 227.6 248.7 279.3
Length mm 3385 3385 3385 3415 3475 3900 4100 4160 4160 4160 4160 4450
Width mm 970 970 1060 1060 1060 1160 1160 1160 1160 1300 1540 1540
Height mm 2000 2000 2000 2000 2000 1940 2100 2100 2100 2160 2160 2214
Weight (4) kg 1380 2000 2320 3110 3280 2400 3610 3740 3820 4100 4600 4750
Model 1400V2 1600V2 1800V2 1600V4 1800V4 2000V4 2200V4 2400V4 2600V4 2800V4 3200V4 3600V4
Cooling capacity (1) kW 1470.5 1612.3 1820.6 1609.2 1789.4 1979.6 2125 2357.9 2644.5 2938 3224.6 3641.2
Cooling capacity (2) kW 1526.4 1673.6 1889.8 1670.3 1857.4 2054.8 2233.8 2447.5 2745 3049.6 3347.1 3779.6
Heating capacity (3) kW 1523.1 1669.8 1888.1 1671.5 1854.1 2043.1 2231 2442.7 2740.3 3043.7 3339.6 3776.1
Qty of compressor n. 2 2 2 4 4 4 4 4 4 4 4 4
Heating capacity of
partial heat recycle
kW 311 338.6 382.3 345 381.7 418.9 455.2 535.6 582.9 635.1 677.2 764.6
Length mm 4510 4510 4510 4100 4160 4160 4160 4160 4450 4510 4510 4510
Width mm 1540 1540 1540 2560 2560 2560 2840 3320 3320 3320 3320 3320
Height mm 2214 2214 2214 2100 2100 2100 2160 2160 2214 2214 2214 2214
Weight (4) kg 4900 5300 5500 7220 7480 7640 8100 9000 9305 9600 10600 11000
(1) Cooling capacity @ evaporator water inlet and outlet temperature 12/7℃, condenser water inlet and outlet temperature 30/35℃;
(2) Water source heating pump cooling capacity @ evaporator water inlet and outlet temperature 12/7℃, condenser water inlet and outlet temperature 15/30℃;
(3) Water source heating pump heating capacity @ evaporator water inlet and outlet temperature 15/6℃, condenser water inlet and outlet temperature 40/45℃;
(4) Exclude the weight of option.
Model 300V1 340V1 400V1 450V1 500V1 550V1 600V1 650V1 700V1 800V1 600V2 700V2 800V2 900V2 1000V2
Cooling capacity (1) kW 274.3 321.8 379.3 443.3 502.1 556 581.9 656 720 757.8 548.5 643.5 758.6 886.7 1004.3
Cooling capacity (2) kW 289.6 339.6 400.3 468.4 530.4 587.6 614.7 692.9 761.4 801.4 579.1 679.3 800.6 936.9 1060.7
Heating capacity (3) kW 296.2 348.1 409.9 475.7 537.7 596.6 624.3 702 755 793.5 592.4 696.3 819.7 951.5 1075.4
Qty of compressor n. 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2
Heating capacity of
partial heat recycle
kw 68.6 80.4 94.8 110.8 125.5 139 145.5 164 180 189.5 137.1 160.9 189.7 221.7 251.1
Length mm 3555 3555 3555 3570 3770 3970 3985 3985 3995 3995 4445 4445 4460 4460 4470
Width mm 1160 1160 1160 1240 1240 1240 1280 1320 1380 1380 1240 1240 1320 1380 1440
Height mm 1630 1630 1630 1880 1880 1880 1880 2070 2070 2070 1670 1670 1720 1930 1990
Weight (4) kg 2350 2500 2780 3060 3200 3435 3740 3940 4060 4210 4435 4720 5530 5950 6260
Model 1100V2 1200V2 1300V2 1400V2 1600V2 1800V2 2000V4 2200V4 2400V4 2600V4 2800V4 2000V4
Cooling capacity (1) kw 1111.9 1163.7 1312 1440 1515.6 1773.3 2008.5 2223.8 2327.5 2624 2880 3031.2
Cooling capacity (2) kw 1175.1 1229.3 1385.8 1522.8 1602.8 1873.7 2121.5 2350.2 2458.7 2771.6 3045.6 3205.6
Heating capacity (3) kw 1193.1 1248.7 1404.1 1510 1587 1902.9 2150.8 2386.2 2497.3 2808.1 3020 3174
Qty of compressor n. 2 2 2 2 2 4 4 4 4 4 4 4
Heating capacity of
partial heat recycle
kw 278 290.9 328 360 378.9 443.3 502.1 556 581.9 656 720 757.8
Length mm 4485 4485 4485 4495 4495 4470 4470 4485 4485 4495 4495 4495
Width mm 1540 1540 1590 1640 1640 2950 2950 2950 2950 2950 2950 2950
Height mm 2040 2040 2180 2230 2230 2480 2540 2640 2710 2760 2780 2780
Weight (4) kg 6950 7410 7810 8020 8350 11900 12520 13900 14820 15620 16040 16700
27
All AIRSYS products are equipped with AIRSYS advanced
microcomputer control system. Hardware meets industrial /
ICT environment requirements, high reliability, anti-jamming.
Control program embodies AIRSY many years’ experience
in ICT environment-air conditioner produce, fully consider
reliable, energy saving, convenient needs, are the core
values embodied AIRSYS products.
By micro-controller, a large number of parameters can
be set flexibly, including automatic / manual, operating
logic selection, parameter calibration, the ON / OFF the
designated member.
Control system
By running status and time records, you can keep
abreast of the operational status of the unit, part of the
on / off status, running time and other information.
Alarm and security alarm information and provide
numerous security protection, including restart, current
and voltage, phase sequence protection, pressure
protection, thermal protection, and so on.
There are several ways to achieve remote monitoring,
remote setting parameters, upload programs, remote
on / off, remote alarm, etc.
Remote Control And Monitoring Network
The unit can be remote controlled or monitored by many
kinds of methods as follows:
3 kinds of local direct cable connection
3 kinds of LAN network connection
4 kinds of wireless network connection
N16
N2
N1
N16
N2
N1
N16
N2
N1
Wireless connection types Local area network connection type
Ethernet network cable
LAN connection 1
LAN connection 2
RS485-RS232 Converter
RS485-RS232 Converter
Units direct connection type
RS485 Bus
RS485 Bus
RS485 BusRS232 cable
RS485-TCP/IP converter with 16 ports
Cooling unit & Comm. card
Single port RS485-TCP/IP converter
Single unit direct connection types
GSM Mobile communication network
GSM communication network
Wireless connection 1
Mobile phone
Mobile phone
GSM module
GSM module
Wireless connection 3
Wireless connection 4
Direct connection 1
Direct connection 2
Direct connection 3
Direct connection 4
wireless communication network
wireless router
Wireless router
The computer is installed with
TCP/IP card RS485 card
RS232 card and IntelliVision plus
software
RS485 card
MODBUS protocol
Wireless connection 2
Monitoring Computer
Airsys Refrigeration Engineering Technology (Beijing) Co., Ltd.
28, Lu Gu Dong Jie, ShijingshanBeijing, China,100040
Tel:+86-10-6865 6161 Fax:+86-10-6865 2453
	
Gu'an Airsys Enviroment Technology Company Ltd.
P.25, St. West Orient, Gu'an Industry Park, Gu'an County, Langfang City, Hebei Province, China.
Tel:+86-10-6865 6161 Fax:+86-10-6865 2453
	
Shanghai Airserve HVAC Systerm Service Co., Ltd.
#7-2,No.658,Daduhe Rd.,Putuo District,Shanghai,China,200333
Tel: +86-21-6245 2626 Fax:+86-21-6245 9622
	
Airsys Group (HK) Co., Ltd.
Room 1305, Carnival Commercial Building, No. 18 Java Road, North Point,Hong Kong
Tel: 00852-2711 0511 Fax: 00852-2711 1511
	
Airsys (UK) Ltd.
Oak House Overbrook Lane Knowsley Business Park Liverpool,UK L34 9FB
Tel: +44-845 2411007 Fax: +44-151 547 8801
	
www.air-sys.com Callcenter:+86-400-820-5515

Weitere ähnliche Inhalte

Was ist angesagt?

Panpisco Technologies - Corporate Profile
Panpisco Technologies - Corporate ProfilePanpisco Technologies - Corporate Profile
Panpisco Technologies - Corporate ProfilePanpisco Technologies
 
Zac india presentation acretech
Zac india presentation   acretechZac india presentation   acretech
Zac india presentation acretechHimanshu Khurana
 
IBL Biotechnology_Brochure
IBL Biotechnology_BrochureIBL Biotechnology_Brochure
IBL Biotechnology_BrochureVincent Merven
 
Dimplex Commercial Heating - Brochure
Dimplex Commercial Heating - BrochureDimplex Commercial Heating - Brochure
Dimplex Commercial Heating - BrochureThorne & Derrick UK
 
Efficient Solutions For The Courier Express And Postal Industry
Efficient Solutions For The Courier Express And Postal IndustryEfficient Solutions For The Courier Express And Postal Industry
Efficient Solutions For The Courier Express And Postal IndustryThorne & Derrick UK
 
Efficient Solutions For The Electronics And Solar Industry
Efficient Solutions For The Electronics And Solar IndustryEfficient Solutions For The Electronics And Solar Industry
Efficient Solutions For The Electronics And Solar IndustryThorne & Derrick UK
 
Nexans Corporate Social responsibility 2014
Nexans Corporate Social responsibility 2014Nexans Corporate Social responsibility 2014
Nexans Corporate Social responsibility 2014John Giatras
 
Messung Group: Growing with innovation fo Forty Years
Messung Group: Growing with innovation fo Forty YearsMessung Group: Growing with innovation fo Forty Years
Messung Group: Growing with innovation fo Forty YearsMessung Workplace Technology
 
Kamstrup - Heat Meters & Water Meters Ultrasonic (RHI Compliant MID Class 2 H...
Kamstrup - Heat Meters & Water Meters Ultrasonic (RHI Compliant MID Class 2 H...Kamstrup - Heat Meters & Water Meters Ultrasonic (RHI Compliant MID Class 2 H...
Kamstrup - Heat Meters & Water Meters Ultrasonic (RHI Compliant MID Class 2 H...Thorne & Derrick UK
 
Schneider Electric Innovation Summit 2016.pptx
Schneider Electric Innovation Summit 2016.pptxSchneider Electric Innovation Summit 2016.pptx
Schneider Electric Innovation Summit 2016.pptxSchneider Electric
 
Efficient Solutions For The Printing Industry
Efficient Solutions For The Printing IndustryEfficient Solutions For The Printing Industry
Efficient Solutions For The Printing IndustryThorne & Derrick UK
 
Tech Direct issue 15
Tech Direct issue 15Tech Direct issue 15
Tech Direct issue 15ERIKS UK
 
Analytic Systems>>Innovative Power Conversion Solutions
Analytic Systems>>Innovative Power Conversion SolutionsAnalytic Systems>>Innovative Power Conversion Solutions
Analytic Systems>>Innovative Power Conversion SolutionsAbdo Ali
 

Was ist angesagt? (20)

SELMA BROCHURE 2015 - ENG
SELMA BROCHURE 2015 - ENGSELMA BROCHURE 2015 - ENG
SELMA BROCHURE 2015 - ENG
 
Panpisco Technologies - Corporate Profile
Panpisco Technologies - Corporate ProfilePanpisco Technologies - Corporate Profile
Panpisco Technologies - Corporate Profile
 
Overall linecard 2014
Overall linecard 2014Overall linecard 2014
Overall linecard 2014
 
Zac india presentation acretech
Zac india presentation   acretechZac india presentation   acretech
Zac india presentation acretech
 
IBL Biotechnology_Brochure
IBL Biotechnology_BrochureIBL Biotechnology_Brochure
IBL Biotechnology_Brochure
 
Dimplex Commercial Heating - Brochure
Dimplex Commercial Heating - BrochureDimplex Commercial Heating - Brochure
Dimplex Commercial Heating - Brochure
 
Efficient Solutions For The Courier Express And Postal Industry
Efficient Solutions For The Courier Express And Postal IndustryEfficient Solutions For The Courier Express And Postal Industry
Efficient Solutions For The Courier Express And Postal Industry
 
Efficient Solutions For The Electronics And Solar Industry
Efficient Solutions For The Electronics And Solar IndustryEfficient Solutions For The Electronics And Solar Industry
Efficient Solutions For The Electronics And Solar Industry
 
GROWING WITH INNOVATION FOR FORTY YEARS
GROWING WITH INNOVATION FOR FORTY YEARSGROWING WITH INNOVATION FOR FORTY YEARS
GROWING WITH INNOVATION FOR FORTY YEARS
 
Extech Katalog
Extech KatalogExtech Katalog
Extech Katalog
 
Nexans Corporate Social responsibility 2014
Nexans Corporate Social responsibility 2014Nexans Corporate Social responsibility 2014
Nexans Corporate Social responsibility 2014
 
Bảng catalog sản phảm máy cắt không khí ACB Easypact EVS Schneider
Bảng catalog sản phảm máy cắt không khí ACB Easypact EVS SchneiderBảng catalog sản phảm máy cắt không khí ACB Easypact EVS Schneider
Bảng catalog sản phảm máy cắt không khí ACB Easypact EVS Schneider
 
Messung Group: Growing with innovation fo Forty Years
Messung Group: Growing with innovation fo Forty YearsMessung Group: Growing with innovation fo Forty Years
Messung Group: Growing with innovation fo Forty Years
 
Kamstrup - Heat Meters & Water Meters Ultrasonic (RHI Compliant MID Class 2 H...
Kamstrup - Heat Meters & Water Meters Ultrasonic (RHI Compliant MID Class 2 H...Kamstrup - Heat Meters & Water Meters Ultrasonic (RHI Compliant MID Class 2 H...
Kamstrup - Heat Meters & Water Meters Ultrasonic (RHI Compliant MID Class 2 H...
 
Schneider Electric Innovation Summit 2016.pptx
Schneider Electric Innovation Summit 2016.pptxSchneider Electric Innovation Summit 2016.pptx
Schneider Electric Innovation Summit 2016.pptx
 
Gossen Metrawatt Catalog 2019
Gossen Metrawatt Catalog 2019Gossen Metrawatt Catalog 2019
Gossen Metrawatt Catalog 2019
 
2018 Katalog Metrel
2018 Katalog Metrel2018 Katalog Metrel
2018 Katalog Metrel
 
Efficient Solutions For The Printing Industry
Efficient Solutions For The Printing IndustryEfficient Solutions For The Printing Industry
Efficient Solutions For The Printing Industry
 
Tech Direct issue 15
Tech Direct issue 15Tech Direct issue 15
Tech Direct issue 15
 
Analytic Systems>>Innovative Power Conversion Solutions
Analytic Systems>>Innovative Power Conversion SolutionsAnalytic Systems>>Innovative Power Conversion Solutions
Analytic Systems>>Innovative Power Conversion Solutions
 

Ähnlich wie Airsys Refrigeration Engineering Technology (Beijing) Co.,Ltd - Leader in ICT Cooling

AIRSYS-Expert in ICT Cooling
AIRSYS-Expert in ICT CoolingAIRSYS-Expert in ICT Cooling
AIRSYS-Expert in ICT CoolingManoel Pedrosa
 
Al Noor Projects & Engineering Trading LLC Company profile
 Al Noor Projects & Engineering Trading LLC Company profile Al Noor Projects & Engineering Trading LLC Company profile
Al Noor Projects & Engineering Trading LLC Company profileSajith Solomon
 
Air handlings units catalogue
Air handlings units catalogueAir handlings units catalogue
Air handlings units cataloguenuairedigital
 
Omnik-solar-inverter-manufacturer-catalog
Omnik-solar-inverter-manufacturer-catalogOmnik-solar-inverter-manufacturer-catalog
Omnik-solar-inverter-manufacturer-catalogOmnik Solar
 
Tim Erickson Visual Innovation Resume
Tim Erickson Visual Innovation ResumeTim Erickson Visual Innovation Resume
Tim Erickson Visual Innovation ResumeTim Erickson
 
ACAL BFi HVAC Solutions
ACAL BFi HVAC SolutionsACAL BFi HVAC Solutions
ACAL BFi HVAC SolutionsAnne Stiegler
 
ACAL BFi HVAC Solutions
ACAL BFi HVAC SolutionsACAL BFi HVAC Solutions
ACAL BFi HVAC SolutionsAnne Stiegler
 
EcoCooling IT Sales Manual
EcoCooling IT Sales ManualEcoCooling IT Sales Manual
EcoCooling IT Sales ManualAlan Beresford
 
Air cooled chiller brochure
Air cooled chiller brochureAir cooled chiller brochure
Air cooled chiller brochureKamlesh Ahirwar
 
Citadel100 Presentation
Citadel100 PresentationCitadel100 Presentation
Citadel100 Presentationkarlhennessy
 
Citadel100 Presentation
Citadel100 PresentationCitadel100 Presentation
Citadel100 Presentationguesteb8b2e
 
APC_Ailgarh Seminar.pptx
APC_Ailgarh Seminar.pptxAPC_Ailgarh Seminar.pptx
APC_Ailgarh Seminar.pptxMahendra Singh
 
TAC by Schneider Electric Corporate Presentation
TAC by Schneider Electric Corporate PresentationTAC by Schneider Electric Corporate Presentation
TAC by Schneider Electric Corporate Presentationosumattox
 

Ähnlich wie Airsys Refrigeration Engineering Technology (Beijing) Co.,Ltd - Leader in ICT Cooling (20)

AIRSYS-Expert in ICT Cooling
AIRSYS-Expert in ICT CoolingAIRSYS-Expert in ICT Cooling
AIRSYS-Expert in ICT Cooling
 
Prime Tech. Company Profile
Prime Tech. Company ProfilePrime Tech. Company Profile
Prime Tech. Company Profile
 
Al Noor Projects & Engineering Trading LLC Company profile
 Al Noor Projects & Engineering Trading LLC Company profile Al Noor Projects & Engineering Trading LLC Company profile
Al Noor Projects & Engineering Trading LLC Company profile
 
Air handlings units catalogue
Air handlings units catalogueAir handlings units catalogue
Air handlings units catalogue
 
Omnik-solar-inverter-manufacturer-catalog
Omnik-solar-inverter-manufacturer-catalogOmnik-solar-inverter-manufacturer-catalog
Omnik-solar-inverter-manufacturer-catalog
 
Tim Erickson Visual Innovation Resume
Tim Erickson Visual Innovation ResumeTim Erickson Visual Innovation Resume
Tim Erickson Visual Innovation Resume
 
Clean Technology
Clean TechnologyClean Technology
Clean Technology
 
PROGEN+COMPANY+PROFILE
PROGEN+COMPANY+PROFILEPROGEN+COMPANY+PROFILE
PROGEN+COMPANY+PROFILE
 
ACAL BFi HVAC Solutions
ACAL BFi HVAC SolutionsACAL BFi HVAC Solutions
ACAL BFi HVAC Solutions
 
ACAL BFi HVAC Solutions
ACAL BFi HVAC SolutionsACAL BFi HVAC Solutions
ACAL BFi HVAC Solutions
 
EcoCooling IT Sales Manual
EcoCooling IT Sales ManualEcoCooling IT Sales Manual
EcoCooling IT Sales Manual
 
Air cooled chiller brochure
Air cooled chiller brochureAir cooled chiller brochure
Air cooled chiller brochure
 
GCSS COMPANY PROFILE
GCSS COMPANY PROFILEGCSS COMPANY PROFILE
GCSS COMPANY PROFILE
 
Potentia Engineering profile
Potentia Engineering profile Potentia Engineering profile
Potentia Engineering profile
 
Citadel100 Presentation
Citadel100 PresentationCitadel100 Presentation
Citadel100 Presentation
 
Citadel100 Presentation
Citadel100 PresentationCitadel100 Presentation
Citadel100 Presentation
 
APC_Ailgarh Seminar.pptx
APC_Ailgarh Seminar.pptxAPC_Ailgarh Seminar.pptx
APC_Ailgarh Seminar.pptx
 
Lean in Vestas Nacelles Italy - Best Practice
Lean in Vestas Nacelles Italy - Best PracticeLean in Vestas Nacelles Italy - Best Practice
Lean in Vestas Nacelles Italy - Best Practice
 
TAC by Schneider Electric Corporate Presentation
TAC by Schneider Electric Corporate PresentationTAC by Schneider Electric Corporate Presentation
TAC by Schneider Electric Corporate Presentation
 
Potentia Engineering Profile
Potentia Engineering Profile Potentia Engineering Profile
Potentia Engineering Profile
 

Kürzlich hochgeladen

MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINEMANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINESIVASHANKAR N
 
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
University management System project report..pdf
University management System project report..pdfUniversity management System project report..pdf
University management System project report..pdfKamal Acharya
 
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...ranjana rawat
 
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...ranjana rawat
 
Introduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxIntroduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxupamatechverse
 
Coefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxCoefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxAsutosh Ranjan
 
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Bookingdharasingh5698
 
UNIT-III FMM. DIMENSIONAL ANALYSIS
UNIT-III FMM.        DIMENSIONAL ANALYSISUNIT-III FMM.        DIMENSIONAL ANALYSIS
UNIT-III FMM. DIMENSIONAL ANALYSISrknatarajan
 
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...Christo Ananth
 
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service NashikCall Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service NashikCall Girls in Nagpur High Profile
 
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
Introduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxIntroduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxupamatechverse
 
result management system report for college project
result management system report for college projectresult management system report for college project
result management system report for college projectTonystark477637
 
Introduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxIntroduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxupamatechverse
 
MANUFACTURING PROCESS-II UNIT-1 THEORY OF METAL CUTTING
MANUFACTURING PROCESS-II UNIT-1 THEORY OF METAL CUTTINGMANUFACTURING PROCESS-II UNIT-1 THEORY OF METAL CUTTING
MANUFACTURING PROCESS-II UNIT-1 THEORY OF METAL CUTTINGSIVASHANKAR N
 
Booking open Available Pune Call Girls Pargaon 6297143586 Call Hot Indian Gi...
Booking open Available Pune Call Girls Pargaon  6297143586 Call Hot Indian Gi...Booking open Available Pune Call Girls Pargaon  6297143586 Call Hot Indian Gi...
Booking open Available Pune Call Girls Pargaon 6297143586 Call Hot Indian Gi...Call Girls in Nagpur High Profile
 
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Call Girls in Nagpur High Profile
 

Kürzlich hochgeladen (20)

MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINEMANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
 
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
 
University management System project report..pdf
University management System project report..pdfUniversity management System project report..pdf
University management System project report..pdf
 
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
 
Introduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxIntroduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptx
 
Coefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxCoefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptx
 
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
 
Roadmap to Membership of RICS - Pathways and Routes
Roadmap to Membership of RICS - Pathways and RoutesRoadmap to Membership of RICS - Pathways and Routes
Roadmap to Membership of RICS - Pathways and Routes
 
UNIT-III FMM. DIMENSIONAL ANALYSIS
UNIT-III FMM.        DIMENSIONAL ANALYSISUNIT-III FMM.        DIMENSIONAL ANALYSIS
UNIT-III FMM. DIMENSIONAL ANALYSIS
 
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
 
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service NashikCall Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
 
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
 
Introduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptxIntroduction to Multiple Access Protocol.pptx
Introduction to Multiple Access Protocol.pptx
 
Water Industry Process Automation & Control Monthly - April 2024
Water Industry Process Automation & Control Monthly - April 2024Water Industry Process Automation & Control Monthly - April 2024
Water Industry Process Automation & Control Monthly - April 2024
 
result management system report for college project
result management system report for college projectresult management system report for college project
result management system report for college project
 
Introduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxIntroduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptx
 
MANUFACTURING PROCESS-II UNIT-1 THEORY OF METAL CUTTING
MANUFACTURING PROCESS-II UNIT-1 THEORY OF METAL CUTTINGMANUFACTURING PROCESS-II UNIT-1 THEORY OF METAL CUTTING
MANUFACTURING PROCESS-II UNIT-1 THEORY OF METAL CUTTING
 
Booking open Available Pune Call Girls Pargaon 6297143586 Call Hot Indian Gi...
Booking open Available Pune Call Girls Pargaon  6297143586 Call Hot Indian Gi...Booking open Available Pune Call Girls Pargaon  6297143586 Call Hot Indian Gi...
Booking open Available Pune Call Girls Pargaon 6297143586 Call Hot Indian Gi...
 
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
 

Airsys Refrigeration Engineering Technology (Beijing) Co.,Ltd - Leader in ICT Cooling

  • 1. AIRSYS Refrigeration Engineering Technology (Beijing) Co.,Ltd AIRSYS-P-SC-GENERAL-E1408V01.5 AIRSYS Expert in ICT Cooling
  • 2. 2 Brief Introduction Airsys is a world major player in ICT cooling with a wide range of product including Precision Air-conditioner for computer room and data center, air-conditioner and Intelligent Free Cooling unit for BTS station, air-conditioner and heat exchanger for various type of cabinets, chillers for data center cooling source. All product is highly reliable and energy efficient. Airsys provide the full solution and service to its customer such as product selection, design and development, manufacturing, installation, after-sale service and contract operation. 1995 Founded in Beijing as the distributor of a major European ICT cooling manufacturer, established the national sales & distribution network. 2001 ISO9001 certified. Introduced Airsys Brand Precision Air- conditioner. 2008 New GuAnproduction facility completed, 30,000 sqm of covered plant and 80,000 sqm of total area, became one of the leader in ICT cooling. “2008 Technology Innovation Award for Green Telecom China” Became global supplier for Siemens Healthcare. 2009 Became global s supply various IC 1999 Introduced Airsys Brand chiller and become a HVAC manufacturer. 2007 Obtained the record making shelter air-conditioner PO from Reliance Communication, an Indian telecom operation. Became strategic partner of China Mobile to develop the high energy efficient air-conditioner for its green shelter project.
  • 3. 3 2006 Attended the ITU exhibition and started the strategic development of the international market. 2010 The packaged outdoor shelter air- conditioner passed the quality audit and on site energy efficiency test of Verizon Wireless, became a part of their new shelter HVAC standard. Became its first Chinese supplier and start the bunch supply. 2011 Became the global supplier for Philips Healthcare and got well acknowledged by the customer. Became the global supplier of British Telecom, providing site survey, installation with the newly established Airsys UK. supplier of Vodafone, CT cooling products. 2003 Elected as “Best Employer” by <Fortune> Chinese Edition. Became global supplier for GE Healthcare and got the “Technology Innovation Award” of the year. 2004 New production facility in Beijing completed.
  • 4. 4 Core Value Reliability means supplying reliable products and services and winning trusts from happy customers in order to win the market. Efficiency means optimizing resource distribution to ensure sustainable business development and maximizing profit margins. Responsibility means being responsible to shareholders, customers, employees, suppliers, and the society in large. Respect means respecting to shareholders, customers, employees, suppliers and partners. Reliability Efficiency Responsibility Respect Vision A major global supplier of product and service in ICT and related industries. AIRSYS will always devote to fulfill the social responsibility of all aspects, providing more environment friendly products, protecting the sustainable development of global environment. Also,we contribute to the development of region and happiness, health and sustainable development of employees and their families. Social Responsibility
  • 5. 5 Manufacturing Facility As the largest ICT cooling product manufacturing facility in Asia, Airsys GuAn has a total area of 80,000 sqm among which 30,000 sqm are covered plant. Equipped with production line for heat exchanger, sheet metal, powder painting, assembly line and performance test chamber, this facility can produce different type of ICT cooling product or more than 100,000 units a year. Energy Saving World is facing the challenge of energy shortage, especially in ICT industry,the revolution in information storage, processing and transmission result more and more energy consumption. Energy efficiency has always been the core value and responsibility of Airsys. We use various kind of technologies, such as free cooling chiller, air-conditioner, independent free cooling unit, EC fan, DC compressor, battery cooler, scroll compressor and displacement air distribution scheme, to help our customer to cut their energy bill High Reliability ICT environment cooling requires high reliability. Airsys has always taken reliability as the most important value and build into every aspect of our business process and every employee’s mind. We assure every product produced is highly reliable by selection of component, design validation, IE and QC, 100% test, process control on installation and service. Our product meet various international standard such as CE, UL, RoHS, CCC. Research and Development Our R&D team is formed by experienced HVAC AND electric engineers. Apart from the standard products, we have rich experience in developing custom made products for our customer. We can quickly deliver the technical proposal, prototype, laboratory performance test report and real site test according to customer’s requirement. Service Network Airsys has a well established service network throughout China and major international regions. Our team, call center and CRM platform provide fast and professional service covering installation, emergency intervention, maintenance, contract operation, online failure analysis, IAQ analysis.
  • 6. 6 Telecom Operator – Verizon Wireless Gone through 3 years of real site testing, highly recognized by the customer for its reliability, energy efficiency and overall performance. Specified in the new Verizon Wireless Shelter standard. Become its first Chinese supplier. Telecom Equipment Supplier- ZTE Long Term Partner Supply all range of product from Cabinet cooling to Data Center cooling. ICT Power Equipment Supplier-Delta, Eltek Strategic Partner Supply all range of cooling product from cabinet to data center. Data Center Operator, Internet Companies Supply full solution for Data Center. Telecom Operator – China Mobile Major Cooling Supplier Strategic Partner for “Green Action Plan” Research and consulting service on shelter cooling energy saving and related standard, developing the software for energy saving calculation, product. Supply CRAC for its large Data Center. Telecom Operator – China Telecom Major Cooling Supplier Long Term Partner, supply CRAC for its large Data Center. Telecom Operator – Vodafone Global Cooling Supplier Jointly develop various cooling product with significant energy saving features. Help to improve both CAPEX and OPEX Telecom Operator – British Telecom Global Cooling Supplier Develop custom made cooling product. Provide turnkey solution including site survey, installation, and product supply. Telecom Operator –Reliance Communication Strategic Cooling Supplier Completed Design, Prototype and Pilot order within 3 months, delivered 25,000 units within 12 months period. The units have shown the best of its kind in terms of failure rate, energy consumption in the market of India. Won the Best Supplier Award in year 2007 and 2008. Airsys and ICT Industry
  • 7. 7 Sales and service network Technical Support and Logistic Center EU-CIS-India North America Middle East & Africa Sales & Distribution Asia Pacific: India, Pakistan, Nepal, Australia, Singapore, Indonesia, Malaysia, Vietnam, Philipine EMEA: Russia, France, UK, Romania, Spain, Czek, Italy, Turkey, South Africa, Nigeria. Americas: USA, Canada, Mexico, Peru, Ecuador. Airsys Refrigeration Engineering Technology (Beijing) Co.,Ltd Gu'an Airsys Environmental Technology Co. Ltd Shanghai Airserve HVAC Systerm Service Co., Ltd. Airsys Group (HK) Co., Ltd. Airsys (UK) Ltd.
  • 8. 8 Airsys product &solutions Data CenterTelecom ShelterCabinet MOBILECOOL-OUTDOOR Cooling capacity:3.5~17.9 kW MOBILECOOL-SPLIT Cooling capacity:5.5~14.9kW METROCOOL Cooling capacity:5.2~13.0kW Outdoor condenser and dry cooler Cooling capacity:9.3~83.1 kW FREECOOL Air flow: 1000~3450 m3 /h FREECOOL-HD Air flow: 2400~21600 m3 /h MOBILECOOL-INDOOR Cooling capacity:3.4~13.3 kW OPTIMA-HD.CW/CWD Cooling capacity:42.1~180.9 kW TELECOOL Cooling capacity:0.3~3kW DATACOOL-PACKAGE Cooling capacity:9.1~48.6 kW DATACOOL Cooling capacity:5.8~30.2 kW HYDROCOOL Cooling capacity:229.5~3641.2 kW CRITICOOL Cooling capacity:115~1508 kW CRITICOOL-FC Cooling capacity:114~1493 kW Ventilation & Heat Exchanger Chiller Air- conditioner OPTIMA.DXA/DXW Cooling capacity:17.6~106.7kW OPTIMA-INV.DXA/DXW Cooling capacity:16.3~115.4kW OPTIMA.CW/CWD Cooling capacity:24.8~134.5kW OPTIMA-FC.DXA/DXW Cooling capacity:17.6~106.7kW OPTIMA-FC-INV.DXA/DXW Cooling capacity:16.1~115.4kW
  • 9. 9 OPTIMA/OPTIMA-INV OPTIMA.DXA/DXW OPTIMA family includes standard series of OPTIMA and DC inverter series of OPTIMA-INV, is applicable to large and medium-sized data center and electronic equipment room. It has a wide range cooling capacity, high operating reliability and stability. Equipped with EC fan, precise control of temperature ±1℃, relative humidity ±5% which can assure the reliable and stable environment of the data room. Standard series of OPTIMA has various type of cooling system, direct expansion with air-cooled condenser, direct expansion with water-cooled condenser, chilled water with either single coil or double coil. DC inverter series of OPTIMA-INV has two types of cooling schemes: direct expansion with air-cooled condensers, direct expansion with water-cooled condenser. There are up flow and down flow for supply air and up, down, front and back for return air to meet the different needs of equipment room. All units can be easily maintained from the front. Direct expansion air-cooled (DXA) work with CME or AMAE air-cooled condenser. Direct expansion water-cooled (DXW) work with CMEH dry cooler or central cooling tower and pumping group. Model 16E1A1 20E1A1 26E1A2 30E1A2 35E1A2 40E2A3 50E2A3 60E2A4 70E2A4 80E2A4 90E2A5 100E2A5 Supply air scheme O:Up flow; U:Down flow Power source 380V-3Ph-50Hz Cooling capacity DXA(1) kW 18.9 22.0 28.5 31.9 37.6 46.6 55.1 65.3 74.5 84.6 90.7 103.4 DXW(2) kW 17.6 21.5 27.9 31.2 36.1 45.8 57.2 62.1 72.2 82.3 90.4 106.7 Compressor Hermetic Scroll Type Supply fan Type EC Centrifugal Fan Qty. of fan n. 1 1 1 1 1 2 2 3 3 3 3 3 Air volume m3/h 5750 6320 8900 9600 9600 12600 13600 17800 19200 21000 24600 27900 Electric heater capacity kW 6 6 9 9 9 13.5 13.5 18 18 18 18 18 Humidification capacity Kg/h 3 3 5 5 5 8 8 8 8 8 8 8 Air cooled condenser(DXA) CME5*1 CME8*1 CME10*1 CME10* CME15*1 CME8*2 CME10*2 CME10*2 CME15*2 CME15*2 CME20*2 CME20*2 Width*Depth*Height mm 875*890*1960 1480*890*1960 1750*890*1960 2490*890*1960 3095*890*2050 DXA Weight Kg 310 360 370 410 415 620 670 930 980 1020 1210 1250 DXW Weight Kg 322 374 385 423 431 656 709 971 1013 1076 1256 1300 (1) Return air dry bulb temperature 24℃,RH50%,Outdoor dry bulb temperature35℃; (2) Return air dry bulb temperature 24℃,RH50%,inlet condensing water temperature 30℃, standard water flow.
  • 10. 10 OPTIMA.CW/CWD Model 20A1 30A1 40A2 45A2 55A3 65A3 80A4 100A4 120A5 140A5 Supply air scheme O:Up flow; U:Down flow Power source 380V-3Ph-50Hz Cooling capacity(1) kW 24.8 30.3 40.8 47.7 55.8 66.5 80.5 100.2 112.1 134.5 Supply fan Type EC Centrifugal Fan Qty. of fan n. 1 1 1 1 2 2 3 3 3 3 Air volume m3/h 6750 6750 9600 9600 15300 15300 21600 21600 28900 28900 Electric heater capacity kW 6 6 9 9 13.5 13.5 18 18 18 18 Humidification capacity Kg/h 3 3 5 5 8 8 8 8 8 8 Width*Depth*Height mm 875*890*1960 1480*890*1960 1750*890*1960 2490*890*1960 3095*890*2050 CW Weight Kg 310 335 380 410 470 510 550 575 660 690 CWD Weight Kg 327 356 408 448 504 556 600 642 730 785 (1) Return air dry bulb temperature 24℃,RH50%,inlet/outlet chilled water temperature 7℃/12℃. Model 16E1A1 22E1A2 30E1A2 35E2A3 45E2A3 55E2A3 60E2A4 70E2A4 80E2A4 90E2A5 110E2A5 Supply air scheme O:Up flow; U:Down flow Power source 380V-3Ph-50Hz Cooling capacity DXA(1) kW 16.3 22.3 30.2 36.9 47.2 55.2 61.6 70.8 80.3 92.3 112.8 DXW(2) kW 17.2 23.5 32.1 36.8 48.1 56.4 63.5 73.5 82.3 93.7 115.4 Compressor Hermetic DC Inverter Scroll Type Supply fan Type EC Centrifugal Fan Qty. of fan 1 1 1 2 2 2 3 3 3 3 3 Air volume 5750 8900 9600 12600 12600 13600 17800 19200 21000 24600 27900 Electric heater capacity n. 6 9 9 13.5 13.5 13.5 18 18 18 18 18 Humidification capacity Kg/h 3 5 5 8 8 8 8 8 8 8 8 Air cooled condenser(DXA) Model*n. AMAE6*1 AMAE8*1 AMAE10*1 AMAE6*2 AMAE8*2 AMAE8*2 AMAE10*2 AMAE12*2 AMAE15*2 AMAE18*2 AMAE20*2 Dry cooler(DXW) Model*n. CMEH20*1 CMEH30*1 CMEH40*1 CMEH50*1 CMEH60*1 CMEH70*1 CMEH80*1 CMEH50*2 CMEH50*2 CMEH60*2 CMEH70*2 Width*Depth*Height mm 875*890*1960 1480*890*1960 1750*890*1960 2490*890*1960 3095*890*2050 DXA Weight Kg 348 440 475 710 750 790 960 1010 1150 1270 1350 DXW Weight Kg 395 490 510 750 810 860 1080 1130 1250 1430 1540 (1) Return air dry bulb temperature 24℃,RH50%,outdoor dry bulb temperature35℃, variable speed compressor is operating at economicspeed; (2) Return air dry bulb temperature 24℃,RH50%, inlet condensing water temperature 30℃, water flow under standard condition, variable speed compressor is operating at economic speed . OPTIMA-INV.DXA/DXW
  • 11. 11 OPTIMA-FC/OPTIMA-FC-INV OPTIMA-FC precision air conditioner integrated with free cooling for critical application,including standard series of OPTIMA-FC and DC inverter series of OPTIMA-FC-INV, is applicable to large and medium-sized data center and electronic equipment room. It has a wide range cooling capacity, high operating reliability and stability. Equipped with EC fan, precise control of temperature±1℃, relative humidity ±5% which can assure the reliable and stable environment of the data room.For double cooling source version, the unit can provide cooling by either chilled water or direct expansion cooling, providing higher reliability and flexibility for efficient operation. Free Cooling version can greatly reduce the energy consumption and cut the energy bill. OPTIMA-FC/OPTIMA-FC-INV has two direct expansion cooling type, air- cooled and water-cooled. There are two schemes of supply air--up supply and down supply can be provide to different needs of equipment room. Easily maintain from the front of the product. OPTIMA-FC/OPTIMA-FC-INV has three working mode:mechanical cooling, partial free cooling and free cooling only. OPTIMA-FC/OPTIMA-FC-INV series double cooling source version has three working mode, mechanical cooling, chilled water cooling and double cooling source. Direct expansion air-cooled (DXA) work with CME or AMAE condenser. Direct expansion water-cooled (DXW) work with CMEH dry cooler or central cooling tower and pumping group. Chilled water coil work with chiller plant, central cooling tower or CMEH dry cooler and pumping group. OPTIMA-FC.DXA/DXW Model 16E1A1 20E1A1 26E1A2 30E1A2 35E1A2 40E2A3 50E2A3 60E2A4 70E2A4 80E2A4 90E2A5 100E2A5 Supply air scheme O:Up flow; U:Down flow Power source 380V-3Ph-50Hz Cooling capacity DXA(1) kW 18.9 22 28.5 31.9 37.6 46.6 55.1 65.3 74.5 84.6 90.7 103.4 DXW(2) kW 17.6 21.5 27.9 31.2 36.1 45.8 57.2 62.1 72.2 82.3 90.4 106.7 Free cooling capacity(3) DXA kW 16.5 21.8 30.1 33.6 37.6 42.4 50.3 55.9 67.3 78.5 93.4 104.6 DXW kW 16.5 21.8 30.1 33.6 37.6 42.4 50.3 55.9 67.3 78.5 93.4 104.6 Compressor Hermetic Scroll Type Supply fan Type EC Centrifugal Fan Qty. of fan n. 1 1 1 1 1 2 2 3 3 3 3 3 Air volume m3/h 5750 6320 8900 9600 9600 12600 13600 17800 19200 21000 24600 27900 Electric heater capacity kW 6 6 9 9 9 13.5 13.5 18 18 18 18 18 Humidification capacity Kg/h 3 3 5 5 5 8 8 8 8 8 8 8 Air cooled condenser(DXA) Model*n. CME5*1 CME8*1 CME10*1 CME10* CME15*1 CME8*2 CME10*2 CME10*2 CME15*2 CME15*2 CME20*2 CME20*2 Dry cooler(DXA) Model*n. CMEH20*1 CMEH30*1 CMEH40*1 CMEH40*1 CMEH50*1 CMEH50*1 CMEH60*1 CMEH60*1 CMEH70*1 CMEH80*1 CMEH50*2 CMEH60*2 Dry cooler(DXW) Model*n. CMEH20*1 CMEH30*1 CMEH40*1 CMEH40*1 CMEH50*1 CMEH60*1 CMEH70*1 CMEH80*1 CMEH50*2 CMEH50*2 CMEH60*2 CMEH70*2 Width*Depth*Height mm 875*890*1960 1480*890*1960 1750*890*1960 2490*890*1960 3095*890*2050 DXA Weight Kg 315 366 375 413 420 630 680 940 980 1040 1230 1270 DXW Weight Kg 348 405 423 464 476 708 770 1037 1085 1157 1338 1392 (1) Return air dry bulb temperature 24℃,RH50%,Outdoor dry bulb temperature35℃; (2) Return air dry bulb temperature 24℃,RH50%,inlet chilling water temperature 30℃, standard chilling water flow under standard condition; (3) Return air dry bulb temperature 24℃,RH50%,Outdoor temperature 2℃, standard chilling water flow under standard condition.
  • 12. 12 OPTIMA-FC-INV.DXA/DXW Model 16E1A1 22E1A2 30E1A2 35E2A3 45E2A3 55E2A3 60E2A4 70E2A4 80E2A4 90E2A5 110E2A5 Supply air scheme O:Up flow; U:Down flow Power source 380V-3Ph-50Hz Cooling capacity DXA(1) kW 16.1 22.2 30.1 35.5 46.7 55.2 61.2 70.3 80.1 91.5 111.9 DXW(2) kW 17.2 23.5 32.1 36.8 48.1 56.4 63.5 73.5 82.3 93.7 115.4 Free cooling capacity(3) DXA(3) kW 17.1 23.5 34.5 37.8 41.7 57.1 63.6 75.3 84.4 93.4 114.6 DXW(3) kW 17.1 23.5 34.5 37.8 41.7 57.1 63.6 75.3 84.4 93.4 114.6 Compressor Hermetic DC Inverter Scroll Type Supply fan Type EC Centrifugal Fan Qty. of fan n. 1 1 1 2 2 2 3 3 3 3 3 Air volume m3/h 5750 8900 9600 12600 12600 13600 17800 19200 21000 24600 27900 Electric heater capacity kW 6 9 9 13.5 13.5 13.5 18 18 18 18 18 Humidification capacity Kg/h 3 5 5 8 8 8 8 8 8 8 8 Air cooled condenser(DXA) Model*n. AMAE6*1 AMAE8*1 AMAE10*1 AMAE6*2 AMAE8*2 AMAE8*2 AMAE10*2 AMAE12*2 AMAE15*2 AMAE18*2 AMAE20*2 Dry cooler(DXA) Model*n. CMEH20*1 CMEH30*1 CMEH40*1 CMEH50*1 CMEH60*1 CMEH70*1 CMEH80*1 CMEH50*2 CMEH50*2 CMEH60*2 CMEH70*2 Dry cooler(DXW) Model*n. CMEH20*1 CMEH30*1 CMEH40*1 CMEH50*1 CMEH60*1 CMEH70*1 CMEH80*1 CMEH50*2 CMEH50*2 CMEH60*2 CMEH70*2 Width*Depth*Height mm 875*890*1960 1480*890*1960 1750*890*1960 2490*890*1960 3095*890*2050 DXA Weight Kg 375 490 510 750 790 830 1080 1130 1220 1420 1510 DXW Weight Kg 405 520 540 790 830 875 1120 1160 1280 1470 1590 (1) Return air dry bulb temperature 24℃,RH50%,outdoor dry bulb temperature35℃, variable speed compressor is operating at economic speed; (2) Return air dry bulb temperature 24℃,RH50%,inlet chilling water temperature 30℃, chilling water flow under standard condition, variable speed compressor is operating at economic speed; (3) Return air dry bulb temperature 24℃,RH50%,outdoor temperature 2℃, chilling water flow under standard condition.
  • 13. 13 OPTIMA-HD OPTIMA-HD is one type of precision air conditioners with high density cooling capacity by using chilled water, applicable to large and medium- sized data center and electronic equipment room. It has a wide range cooling capacity, high operating reliability and stability, the density of cooling capacity is up to 75kW/m2 which can save a lot of space in equipment room. Equipped with EC fan, OPTIMA-HD has a high operating efficiency, precise control of temperature +/- 1℃, relative humidity +/-5% which can assure the reliable and stable environment of the data room. There are three air flow schemes, up flow, down flow and front flow under rise floor can be provide to different needs of equipment room. Easily maintain from the front of the product. OPTIMA-HD use chilled water as cooling resource for mechanical cooling or free cooling. The system has the characteristics of simple structure, reliable and save the operating expense . OPTIMA-HD has two types: single circuit and dual circuits. Each circuit of dual circuits can be redundancy each other or work simultaneously or rotation between mechanical cooling and chilled water of free cooling. (1) Return air dry bulb temperature 24℃,RH50%,inlet/outlet chilled water temperature 7℃/12℃; (2) Excluding the height of return air plenum of up flow unit and supply air plenum of down flow unit. Model 40B1 60B1 80B2 100B2 120B3 140B3 160B4 180B4 50D1 60D1 80D2 100D2 120D3 140D3 Circuit CW: single circuit CWD: double circuit Supply air scheme O:Up flow; U:Down flow U:Down flow Power source 380V-3Ph-50Hz 380V-3Ph-50Hz Cooling capacity(1) kW 42.1 60.7 83.6 101.6 123.3 145.2 160.5 180.9 50.4 61.1 81.0 100.7 120.5 143.2 Water flow(1) m3/h 7.2 9.6 14.2 17.3 19.5 24.7 26.3 28.4 7.7 9.6 12.7 14.8 17.9 22.0 Water pressure drop(1) kPa 95 97 86 94 93.6 91.2 98.6 83.9 101.1 123.1 83.1 83.2 184.6 156.6 Supply fan Type EC Centrifugal Fan EC Centrifugal Fan Qty. of fan n. 1 1 2 2 3 3 3 3 1 1 2 2 3 3 Air volume m3/h 11700 12600 22600 23600 31800 32600 37200 37200 11600 12300 23600 22800 31200 33600 Electric heater capacity kW 9 9 13.5 13.5 18 18 18 18 9 9 13.5 13.5 13.5 13.5 Humidification capacity Kg/h 8 8 8 8 8 8 8 8 8 8 8 8 8 8 Width*Depth*Height(O/U)(2) mm 900*900*1960/1730 1750*900*1960/1730 2490*900*1960/1730 2905*900*1960/1730 1250*900*1900 1750*900*1900 2560*900*1900 Weight Kg 375 405 525 560 670 750 840 910 380 405 465 490 580 640
  • 14. 14 DATACOOL Precision air conditioning units are widely applied in small/medium data center and computer rooms. DADATCOOL unit adopts new technologies, using efficient compressor and fans and optimizing refrigerating system configuration, to achieve its high efficiency and reliability, realizing COP >2.9, temperature control accuracy <±1℃ while humidity control accuracy <±5%. The compact structure and light weight makes easy installation. The unit can be fully maintained from the front, greatly reducing the maintenance cost. DATACOOL unit is available in 4 different air flow scheme: front up flow, down flow, displacement flow, top flow, offering more options for different customers. DATACOOL (1) Return air dry bulb temperature 24℃,RH50%,Outdoor dry bulb temperature35℃. Model 5E1C0 7E1C0 13E1C0 7E1C1 10E1C1 13E1C1 15E1C2 18E1C2 22E1C3 25E1C3 30E1C3 Supply air scheme O: up-front throw O: up-front throw; U: Bottom Throw; DL: Replacement; TP: top throw Power source 380V-3Ph-50Hz Cooling capacity(1) 5.8 7.4 13.2 7.6 10.7 13.6 15.4 18.3 22.2 25.4 30.2 Compressor Rotor Hermetic Scroll Supply fan Qty. of fan n. 1 1 1 1 1 1 1 1 2 2 2 Air volume m3/h 1650 1650 2630 2450 2450 2950 3450 3450 5100 6500 6500 Electric heater capacity kW 2.3 2.3 4.5 2.3 4.5 4.5 6 6 9 9 9 Humidification capacity Kg/h 3 3 3 3 3 3 5 5 5 8 8 Air cooled condenser CMD3*1 CMD4*1 CMD5*1 CMD4*1 CMD4*1 CMD5*1 CME5*1 CME8*1 CME8*1 CME10*1 CME10*1 Width*Depth*Height mm 650*580*1910 650*650*1910 900*750*1910 1300*750*1910 Weight Kg 120 135 155 142 165 180 255 290 370 460 490 DATACOOL-PACKAGE air conditioner with built-in fresh air free cooling system is specially designed for small/medium data center and electronic equipment room. Due to its proper working logic and standard EC supply fan, DATACOOL- PACKAGE can maximum works in free cooling mode with the lowest power consumption, saving huge energy and lowering the operation cost. DATACOOL-PACKAGE is a self-contained air conditioning unit which realizes easy installation without any refrigeration piping connection. The unit can be fully maintained from the front, greatly reducing the maintenance cost as well. DATACOOL-PACKAG is available in 2 different air flow schemes: up flow and down flow, offering more options for different customers to increase its application flexibility. DATACOOL-PACKAGE (1) Return air dry bulb temperature 24℃,RH50%,Outdoor dry bulb temperature35℃; (2) Indoor temperature and outdoor temperature difference (ΔT) is 10℃. Model 8E1A1 15E1A1 22E1A2 30E2A2 45E2A3 Supply air scheme O:Up flow; U:Down flow Power source 380V-3Ph-50Hz Cooling capacity(1) kW 9.1 16.5 23.9 33 48.6 Free cooling capacity(2) kW 13.1 18.5 25 27.5 50 Compressor Hermetic Scroll Type Evaporator fan Type EC Centrifugal Fan Qty. of fan n. 1 1 1 1 2 Air volume m3/h 4350 6150 8320 9150 16640 Condenser fan Type EC Centrifugal Fan Qty. of fan n. 1 1 1 2 4 Air volume m3/h 4200 5100 5800 10200 14400 Electric heater capacity kW 4.5 4.5 4.5 6 9 Width*Depth*Height(packaged unit) mm 1160*1050*2350 1460*1100*2350 2920*1100*2350 Width*Depth*Height(split unit) 1160*1050*2450 1460*1100*2450 2920*1100*2450 Weight (packaged unit) Kg 450 520 610 660 1280 Weight (split unit) Kg 500 570 680 730 1420
  • 15. 15 MOBILECOOL-OUTDOOR MOBILECOOL-OUTDOOR is a package type telecommunication base station special air conditioner and designed for telecommunication base station, small electronic equipment room. The unit features including good structure, easy maintenance, high sensible ratio, high efficiency, and high reliability. The air supplied from the front lower portion of the unit, which conforms with the air flow rules well, making the heat exchange more efficiency. MOBILECOOL-OUTDOOR uses EC fan supplied with alternating current (direct current is optional). The unit is available in single or dual-control, supplying various running strategies. The free cooling function is standard configuration, saving the energy consumption highly. MOBILECOOL-OUTDOOR installed in the outside of the shelter. The installation type can save the space of shelters. Model 3R1C1 5E1C1 7E1C2 10E1C2 13E1C3 18E1C4 7E1C2 10E1C2 13E1C3 18E1C4 Supply air scheme DL:Replacement DL:Replacement Power source 230V-1Ph-60Hz 230V-3Ph-60Hz Cooling capacity(1) kW 3.5 5 8.1 10 13.4 17.8 8.1 10 13.4 17.8 Free cooling capacity(2) kW 3.4 4.0 7.1 8.2 8.9 12.9 7.1 8.2 8.9 12.9 Compressor Rotory Scroll Scroll Evaporator fan Type EC Centrifugal Fan EC Centrifugal Fan Air volume m3/h 1000 1200 2120 2460 2650 3850 2120 2460 2650 3850 Condenser fan Type Axial Axial Air volume m3/h 3400 3400 5000 6300 6300 8200 5000 6300 6300 8200 Width*Depth*Height mm 620*620*1930 930*700*2139 1080*700*2139 1280*700*2139 930*700*2139 1080*700*2139 1280*700*2139 Weight Kg 135 145 235 240 280 320 235 240 280 320 Model 3R1C1 5E1C1 7E1C2 10E1C2 13E1C3 18E1C4 5E1C1 7E1C2 10E1C2 13E1C3 18E1C4 Supply air scheme DL:Replacement DL:Replacement Power source 220V-1Ph-50Hz 380V-3Ph-50Hz Cooling capacity(1) kW 3.5 5.2 7.5 10.8 13.4 17.5 5.2 7.5 10.8 13.4 17.9 Free cooling capacity(2) kW 3.4 4.0 7.1 8.2 8.9 12.9 4.0 7.1 8.2 8.9 12.9 Compressor Rotory Scroll Scroll Evaporator fan Type EC Centrifugal Fan EC Centrifugal Fan Air volume m3/h 1000 1200 2120 2460 2650 3850 1200 2120 2460 2650 3850 Condenser fan Type Axial Axial Air volume m3/h 3200 3200 4200 5800 5800 7500 3200 4200 5800 5800 7500 Width*Depth*Height mm 620*620*1930 930*700*2139 1080*700*2139 1280*700*2139 620*620*1930 930*700*2139 1080*700*2139 1280*700*2139 Weight Kg 135 145 235 240 280 320 145 235 240 280 320 (1) Return air dry bulb temperature 27℃、RH50%,Outdoor dry bulb temperature35℃; (2) Indoor temperature and outdoor temperature difference (ΔT) is 10℃.
  • 16. 16 MOBILECOOL-INDOOR MOBILECOOL-INDOOR is a package type telecommunication base station special air conditioner and designed for telecommunication base station, small electronic equipment room. The unit features including good structure, easy maintenance, high sensible ratio, high efficiency, and high reliability. The air supplied from the front lower portion of the unit, which conforms with the air flow rules well, making the heat exchange more efficiency. MOBILECOOL-INDOOR uses EC fan supplied with alternating current (direct current is optional). The unit is available in single or dual-control, supplying various running strategies. The free cooling function is standard configuration, saving the energy consumption highly. MOBILECOOL-INDOOR installed in the inside of the shelter. The installation type is anti-theft, protecting the air conditioner from bad environment. (1) Return air dry bulb temperature 27℃,RH50%,Outdoor dry bulb temperature35℃; (2) Indoor temperature and outdoor temperature difference (ΔT) is 10℃. Model 3R1D0 5E1D1 7E1D2 10E1D3 13E1D4 7E1D2 10E1D3 13E1D4 Supply air scheme DL:Replacement DL:Replacement Power source 230V-1Ph-60Hz 230V-3Ph-60Hz Cooling capacity(1) kW 3.4 5 7.9 9.8 13.2 7.9 9.8 13.2 Free cooling capacity(2) kW 3.4 4.0 7.1 8.2 8.9 7.1 8.2 8.9 Compressor Rotory Scroll Scroll Evaporator fan Type EC Centrifugal Fan EC Centrifugal Fan Air volume m3/h 1000 1200 2120 2460 2650 2120 2460 2650 Condenser fan Type Centrifugal Fan Centrifugal Fan Air volume m3/h 2400 2800 2800 4200 5600 2800 4200 5600 Width*Depth*Height mm 500*600*2000 600*600*2000 750*650*2100 860*650*2100 1010*650*2100 750*650*2100 860*650*2100 1010*650*2100 Weight Kg 130 160 200 255 290 200 255 290 Model 3R1D0 5E1D1 7E1D2 10E1D3 13E1D4 5E1D1 7E1D2 10E1D3 13E1D4 Supply air scheme DL:Replacement DL:Replacement Power source 220V-1Ph-50Hz 380V-3Ph-50Hz Cooling capacity(1) kW 3.4 5.2 7.4 10.6 13.3 5.2 7.4 10.6 13.3 Free cooling capacity(2) kW 3.4 4.0 7.1 8.2 8.9 4.0 7.1 8.2 8.9 Compressor Rotory Scroll Scroll Evaporator fan Type EC Centrifugal Fan EC Centrifugal Fan Air volume m3/h 1000 1200 2120 2460 2650 1200 2120 2460 2650 Condenser fan Type Centrifugal Fan Centrifugal Fan Air volume m3/h 2400 2800 2800 4200 5600 2800 2800 4200 5600 Width*Depth*Height mm 500*600*2000 600*600*2000 750*650*2100 860*650*2100 1010*650*2100 600*600*2000 750*650*2100 860*650*2100 1010*650*2100 Weight Kg 130 160 200 255 290 160 200 255 290
  • 17. 17 MOBILECOOL-SPLIT MOBILECOOL-SPLIT is a spilt type telecommunication base station special air conditioner and designed for telecommunication base station, small electronic equipment room. The unit features including good structure, easy maintenance, high sensible ratio, high efficiency, and high reliability. The air supplied from the front lower portion of the unit, which conforms with the air flow rules well, making the heat exchange more efficiency. MOBILECOOL-SPLIT uses AC fan supplied with alternating current (direct current is optional). The unit is available in single or dual-control, supplying various running strategies. The free cooling function is optional, saving the energy consumption highly. Model 5R1D1 7R1D1 10E1D2 13E1D2 15E1D2 Supply air scheme O:Up flow; DL: Replacement Power source 220V-1Ph-50Hz 380V-3Ph-50Hz Cooling capacity(1) kW 5.5 7.6 10.4 13.3 14.9 Free cooling capacity(2) kW 5.9 5.9 7.4 11.6 11.6 Compressor Hermetic Rotary Type Hermetic Scroll Type Supply fan Type AC Centrifugal Fan Air volume m3/h 1800 1800 2250 3500 3500 Width*Depth*Height mm 600*500*1700 600*500*1700 750*500*1700 750*500*1700 750*500*1700 Weight kg 70 80 150 160 165 Condenser unit Model CMD3 CMD4 CMD4 CMD5 CMD6 Width*Depth*Height mm 808*509*789 808*509*789 808*509*789 1004*509*930 1250*509*930 Weight kg 29 35 35 43 92 (1) Return air dry bulb temperature 27℃,RH50%,Outdoor dry bulb temperature35℃; (2) Indoor temperature and outdoor temperature difference (ΔT) is 10℃(only for DL air supply scheme unit).
  • 18. 18 METROCOOL METROCOOL unit is specially designed for industry environment, standing up to high temperature, heavy pollution and continuous working demand and offering high efficiency, strict fire proofing, various power supplies and widely working condition with high reliability. METROCOOL is a split air conditioning unit with rational structure for convenient maintenance. Electrical heaters with different capacity are available for this unit as options to satisfy different application requirement. Model MTC.5 MTC.7 MTC.10 MTC.13 MTC.5 MTC.7 MTC.10 MTC.13 MTC.5 MTC.7 MTC.10 MTC.13 Power source 380V-3Ph-50Hz 220V-1Ph-50Hz 208~230V-1Ph-60Hz Cooling capacity(1) kW 5.2 7.3 10.0 13.0 5.2 7.3 10.0 13.0 5.0 6.8 10.7 13.0 Unit max. operating power input kW 3.2 3.9 5.3 6.5 3.4 4.0 5.5 6.5 2.9 3.8 5.3 6.8 Unit max. operating current A 8.0 9.5 12.2 16.5 14.7 18.9 27.0 24.6 13.1 16.6 24.8 31.2 Indoor unit Fan type Double Inlet Centrifugal Fan Double inlet Centrifugal Fan Double inlet Centrifugal Fan Air volume m3/h 1400 1400 1600 2000 1400 1400 1600 2000 1400 1400 1600 2000 Width*Depth*Height mm 1295*280*680 1295*310*870 1295*280*680 1295*310*870 1295*280*680 1295*310*870 Weight Kg 52 54 64 67 52 54 64 67 52 54 64 67 Outdoor unit Compressor Hermetic scroll type Hermetic scroll type Hermetic scroll type Fan type Axial flow fan Axial flow fan Axial flow fan Width*Depth*Height mm 1260*590*880 1440*590*1125 1305*590*1500 1260*590*880 1440*590*1125 1305*590*1500 1260*590*880 1440*590*1125 1305*590*1500 Weight Kg 91 95 123 145 91 95 123 145 91 95 123 145 Piping connection Condensing water drainage mm 16 16 16 16 16 16 16 16 16 16 16 16 Refrigerant liquid in 3/8″ 1/2″ 1/2″ 1/2″ 1/2″ 1/2″ 1/2″ 1/2″ 1/2″ 1/2″ 1/2″ 1/2″ Refrigerant gas in 1/2″ 5/8″ 3/4″ 3/4″ 5/8″ 5/8″ 3/4″ 3/4″ 5/8″ 5/8″ 3/4″ 3/4″ (1) Top grade air flow, return air dry bulb temperature 27℃,wet bulb temperature 19℃,outdoor dry bulb temperature35℃, wet bulb temperature 24℃.
  • 19. 19 TELECOOL Cabinet air condition is actively cooling with compressor, and it will remove the heat inside the cabinet to outside. It also can keep the dust and heat outside the cabinet, avoiding problems from using fan. The inside cabinet can be maintained at an ideal temperature for electrical components which effectively guarantees the stability of the electronic equipment and improves the reliability of the whole system. The products can be widely used for outdoor communication cabinets, battery cabinets, electric cabinets, industry control cabinets etc. (1) Return air dry bulb temperature 35℃,outdoor dry bulb temperature35℃. (1) Return air dry bulb temperature 35℃,outdoor dry bulb temperature35℃. Model TC.AC.300 TC.AC.400 TC.AC.600 TC.AC.800 TC.AC.1000 TC.AC.1200 TC.AC.1500 TC.AC.2000 TC.AC.2500 TC.AC.3000 Cooling Capacity(L35/L35) W 300 400 600 800 1000 1200 1500 2000 2500 3000 Rated Power W 220 240 365 460 490 610 685 830 1020 1240 Working Voltage 220VAC±15% 50/60Hz Working Temperature -40~55℃ Refrigerant R134a R134a/R22 Noise dB 55 55 56 58 60 62 64 68 68 70 Ambient Air Circuit m3/h 280 280 450 450 540 580 780 950 1150 1380 Cabinet Air Circuit m3/h 160 160 200 230 250 360 450 560 640 780 Width*Depth*Height(R134a) mm 353*165*583 455*155*692 482*187*781 497*188*897 460*188*1087 549*220*1208 569*220*1308 Width*Depth*Height(R22) mm / 482*187*781 497*188*897 460*188*1087 549*220*1208 Model TC.DC.400 TC.DC1000 TC.DC.2000 TC.DC.3000 Cooling Capacity(L35/L35) W 400~600 800~1000 1500~2000 2500~3000 Rated Power W 240 450 725 1120 Working Voltage DC 48V Working Temperature -40~55℃ Refrigerant R134a Noise dB 55 60 64 68 Ambient Air Circuit m³/h 450 540 780 1380 Cabinet Air Circuit m³/h 200 250 450 780 Width*Depth*Height mm 455*155*692 482*187*781 497*188*897 549*220*1208
  • 20. 20 FREECOOL-HD FREECOOL-HD intelligent ventilation unit is applied in small/medium data center and electronic equipment room. The unit introduces outdoor fresh air with lower temperature to cool equipment room. By using the FREECOOL-HD unit, the running hours of other air conditioning units can be highly reduced, achieving power energy saving around 30~90%. The FREECOOL-HD unit using EC fans can adjust the air volume automatically according to the temperature difference with the lowest power consumption. FREECOOL-HD without refrigeration system realizes easy installation and convenient maintenance. The unit is available in 2 different air flow schemes: up flow and down flow, and 2 installation positions: outdoor and indoor, offering more options for different customers. Model 24F1 48F2 72F1 144F2 216F3 Supply air scheme O/U Air volume m3 /h 2400 4750 7200 14400 21600 Air volume m3 /s 0.67 1.3 2.0 4.0 6.0 Cooling capacity △t=5℃ kW 4.0 7.9 12.0 24.0 36.0 △t=10℃ kW 8.0 15.8 24.0 48.0 72.0 △t=12℃ kW 9.6 19 28.8 57.6 86.4 Power source 230V/1/(50/60Hz) 400V/3/(50/60Hz) Fan Type Single inlet backward curved centrifugal fan Qty. of fan n. 1 2 1 2 3 Input power kW 0.5 1.0 2.1 4.2 6.3 Current A 3.1 6.1 3.2 6.4 9.4 Width*Depth*Heigh mm 700*450*1320 1150*450*1320 850*800*1770 1650*800*1770 2450*800*1770 Weight kg 65 89 150 260 350
  • 21. 21 FREECOOL FREECOOL intelligent ventilation unit is applied in shelters and small equipment room. The unit introduces outdoor fresh air with lower temperature to cool equipment room. By using the FREECOOL unit, the running hours of other air conditioning units can be highly reduced, achieving power energy saving around 30~90%.The FREECOOL DC series using EC fans can adjust the air volume automatically according to the temperature difference with the lowest power consumption. FREECOOL is able to control up to 2 air conditioners. The unit is available in various installation positions: outdoor and indoor, packaged and split, offering more options for different data centre. Model 12F1 18F1 24F1 30F2 35F2 12F1 18F1 24F1 30F1 35F1 Structure type ID/OD Package ID/OD Split Cooling capacity △t=5℃ kW 1.7 2.4 3.4 4.4 5 1.7 2.9 3.4 5 5.7 △t=10℃ kW 3.1 4.8 6.8 8.7 9.9 3.3 5.8 6.8 10 11.4 △t=12℃ kW 3.8 5.7 8.1 10.5 11.9 4 6.9 8.1 12 13.7 Power source 48VDC;220VAC (Only available for ID installation unit) 48VDC;220VAC (Only available for ID installation unit) Fan Type Single inlet backward curved centrifugal fan Single inlet backward curved centrifugal fan Qty. of fan n. 1 1 1 2 2 1 1 1 1 1 Air volume m3/h 1000 1450 2050 2650 3000 1000 1750 2050 3030 3450 Input power(48VDC) kW 0.06 0.19 0.22 0.3 0.4 0.06 0.19 0.23 0.26 0.39 Input power(220VAC) kW 0.13 0.18 0.39 0.36 0.5 0.13 0.18 0.39 0.38 0.57 Width*Depth*Height(ID) mm 650*500*1100 750*600*1400 550*450*700 600*500*900 Width*Depth*Height(OD) mm 650*500*1320 750*630*1620 550*550*600 610*610*630 Weight(ID) Kg 60 60 65 85 85 40 40 42 48 50 Weight(OD) Kg 65 65 68 115 115 38 38 40 45 45
  • 22. 22 Outdoor condenser and dry cooler The covers of CME air-cooled condenser are produced by aluminum sheet, which has characteristics of light weight, Anti-corrosion, anti-rust, etc. The condenser is equipped with adjustable speed axial fan and high efficiency heater exchanger. Vertical or horizontal installation of the condenser is available. The covers of AMAE air-cooled condenser are produced by aluminum sheet, which has characteristics of light weight, anti-corrosion, anti-rust, etc. The condenser is equipped with EC axial fan which has characteristics of big air volume, lower power consumption and adjustable fan speed and high efficiency heater exchanger. The condenser is suitable for high temperature working conditions. Vertical or horizontal installation of the condenser is available. CMD air-cooled condenser is used for small precision air conditioner or base station air conditioner. The covers of CMD condenser are produced by coating sheet metal, which has characteristics of anti-corrosion, anti-rust, etc. The condenser is equipped with adjustable speed axial fan and high efficiency heater exchanger. Only vertical installation of the condenser is available. The covers of CMEH dry cooler are produced by aluminum sheet, which has characteristics of light weight, Anti-corrosion, anti-rust, etc. The condenser is equipped with adjustable speed axial fan and high efficiency heater exchanger. Vertical or horizontal installation of the condenser is available. CMD/CME (1) Heat dissipating capacity @ inlet air temperature 35℃, condensation temperature 50℃. Model CMD3 CMD4 CMD5 CMD6 CME4 CME5 CME8 CME10 CME15 CME20 CME25 Power source 220V-1Ph-50Hz Capacity (1) kW 9.3 13.7 20.4 23.6 15.6 20.5 29.6 35.4 47.6 67.4 73.1 Fan Qty. of fan n. 1 1 1 1 1 1 1 1 2 2 2 Air volume m3/h 4400 4100 5600 5800 4400 5600 10100 9700 11600 20100 19100 Input power kW 0.28 0.28 0.37 0.37 0.28 0.37 0.63 0.63 0.74 1.26 1.26 Input current A 1.3 1.3 1.7 1.7 1.3 1.7 3 3 3.4 6 6 Gas pipe ODF 5/8" 5/8" 5/8" 5/8" 16 19 22 22 22 28 35 Liquid pipe ODF 1/2" 1/2" 1/2" 1/2" 12 12 16 16 19 19 22 Width*Depth*Height mm 808*509*789 1004*509*930 1250*509*930 840*475*770 1140*475*770 1340*620*1070 1540*620*1070 2400*630*1135 Weight Kg 29 35 43 92 37 47 95 110 130 155 185
  • 23. 23 Model AMAE5 AMAE6 AMAE8 AMAE10 AMAE12 AMAE15 AMAE18 AMAE20 Power source 220V/1Ph/50Hz Capacity (1) kW 24.2 29.7 36.2 41.3 50.7 57.2 62.4 74.3 Fan Qty. of fan n. 1 1 1 1 2 2 2 2 Air volume m3/h 12500 11600 11800 11500 23500 22000 23400 22600 Input power kW 0.63 0.63 0.63 0.63 1.26 1.26 1.26 1.26 Input current A 2.8 2.8 2.8 2.8 5.6 5.6 5.6 5.6 Gas pipe ODF 19 19 19 22 22 22 22 28 Liquid pipe ODF 16 16 16 16 16 16 19 19 Width*Depth*Height mm 1365*620*1080 1665*620*1080 1985*620*1080 2790*620*1080 Weight Kg 103 116 135 152 173 182 206 220 AMAE (1) Heat dissipating capacity @ inlet air temperature 35℃, condensation temperature 50℃. (1) Heat dissipating capacity @ inlet air temperature 35℃, inlet water temperature 45℃. Model CMEH20 CMEH30 CMEH40 CMEH50 CMEH60 CMEH70 CMEH80 Power source 220V/1Ph/50Hz Capacity kW 23.2 31.2 45.3 56.7 61.5 75.2 83.1 Heat exchange coil Water flow m3/h 3.5 5.2 6.2 9.3 10.2 10.6 11.8 Pressure drop kPa 71.1 68.2 58.7 57.6 69.1 72.3 78.5 Fan Qty. of fan n. 1 1 2 2 2 3 3 Air volume m3/h 12100 11200 22800 23200 21800 33600 32400 Nominal mechanical power kW 0.75 0.75 1.5 1.5 1.5 2.3 2.3 Max electric absorption A 3.3 3.3 6.6 6.6 6.6 10.1 10.1 Width*Depth*Height mm 1350*620*1070 1980*620*1120 2700*620*1120 3580*620*1120 Weight Kg 95 115 145 175 195 235 255 CMEH
  • 24. 24 Standard Compact type CRITICOOL/CRITICOOL-FC CRITICOOL series is applicable to large-sized data center and all kinds of industrial technology place. It has a wide range cooling capacity, high operating reliability and stability. CRITICOOL-FC is equipped with additional chilled water coil, free cooling system will be used when outdoor temperature is low enough, minimize the run time of mechanical cooling and save huge energy and lowering the operation cost. CRITICOOL adopts screw compressor, offer built-in pump group as option, the customer only need to connect water pipe and power supply cable on the site. Outdoor installation, no room occupied. Model 130V1 150V1 200V1 250V1 350V1 400V1 450V1 500V1 400V2 450V2 700V2 800V2 Cooling capacity(1) kW 115 138 178 245 315 377 408 475 370 420 630 754 Heating capacity(2) kW 128.8 154.6 199.4 274.4 356 422.2 457 532 414.4 470.4 711.9 844.5 Qty of compressor n. 1 1 1 1 1 1 1 1 2 2 2 2 Heating capacity of partial heat recycle(Option)(3) kW 34 41 56.8 80.5 103.7 120.3 122.4 142.5 118 126 198 216.7 Length mm 3600 3600 4335 5170 4980 4980 4980 6490 4980 6490 7480 8470 Width mm 1290 1290 1290 1290 2130 2130 2130 2130 2130 2130 2130 2130 Height mm 2280 2280 2280 2280 2540 2540 2540 2540 2540 2540 2540 2540 Weight (4) kg 1640 1780 1910 2350 3425 3800 3880 4850 3960 4900 6250 7000 Model 700V2 750V2 800V2 890V2 950V2 1000V2 1100V2 1200V2 900V3 1000V4 1200V4 1400V4 1500V4 1600V4 Cooling capacity(1) kW 630 692 754 816 883 942 1033 1124 880 996 1126 1256 1390 1508 Heating capacity(2) kW 712 778 844 914 991 1066 - - 986 1118 1261 1407 1557 1689 Qty of compressor n. 2 2 2 2 2 2 2 2 3 4 4 4 4 4 Heating capacity of partial heat recycle(Option)(3) kW 189 207.6 226.2 244.8 264.9 282.6 309.9 337.2 264 320.4 396 396 448 481.2 Length mm 6450 6750 7050 7050 8130 9210 10290 11370 8710 10780 11340 12900 13500 14100 Width mm 2350 2350 2350 2350 2350 2350 2350 2350 2350 2350 2350 2350 2350 2350 Height mm 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 Weight (4) kg 6760 7080 7400 7650 8190 9260 10280 11300 9520 11920 12740 13520 14160 14800 (1) Nominal cooling capacity @ outside DB is 35℃, chilled water outlet temperature 7℃, inlet temperature 12℃; (2) Nominal heating capacity @ outside DB is 7℃, WB is 6℃; hot water outlet tempreature 45℃, inlet tempreature 40℃; (3) The inlet temperature of heat recycle 40℃; (4) Exclude the weight of option. (1) Nominal cooling capacity @ outside DB is 35℃, chilled water outlet temperature 7℃, inlet temperature 12℃; (2) Nominal heating capacity @ outside DB is 7℃, WB is 6℃; hot water outlet tempreature 45℃, inlet tempreature 40℃; (3) The inlet temperature of heat recycle 40℃; (4) Exclude the weight of option.
  • 25. 25 (1) Nominal cooling capacity @ outside DB is 35℃, chilled water outlet temperature 7℃, inlet temperature 12℃; (2) Nominal heating capacity @ outside DB is 7℃, WB is 6℃; hot water outlet tempreature 45℃, inlet tempreature 40℃; (3) The inlet temperature of heat recycle 40℃; (4) Exclude the weight of option. (1) Nominal cooling capacity @ outside DB is 35℃, chilled water outlet temperature 7℃, inlet temperature 12℃; (2) Nominal heating capacity @ outside DB is 7℃, WB is 6℃; hot water outlet tempreature 45℃, inlet tempreature 40℃; (3) The inlet temperature of heat recycle 40℃; (4) Exclude the weight of option. Standard free cooling type Model  350V1 400V1 450V1 500V1 600V1 700V2 750V2 Cooling capacity(1) kW 312 373 404 470 557 624 685 Cooling capacity(2) kW 346 414 448 522 619 692 760 Free cooling capacity(3) kW 348 416 451 525 622 696 764 Qty. of compressors n. 1 1 1 1 1 2 2 Length mm 3410 3710 3710 4790 5870 6450 6750 Width mm 2350 2350 2350 2350 2350 2350 2350 Height mm 2600 2600 2600 2600 2600 2600 2600 Weight kg 3780 4140 4305 5130 6240 7560 7880 Model 800V2 890V2 950V2 1000V2 1200V2 1400V2 1600V2 Cooling capacity(1) kW 746 808 874 931 1115 1271 1493 Cooling capacity(2) kW 829 897 970 1034 1237 1411 1657 Free cooling capacity(3) kW 833 901 975 1039 1244 1418 1665 Qty. of compressors n. 2 2 2 2 2 2 2 Length mm 7050 7050 8130 9210 10290 11370 14100 Width mm 2350 2350 2350 2350 2350 2350 2350 Height mm 2600 2600 2600 2600 2600 2600 2600 Weight kg 8350 8590 9270 11320 13300 14100 16000 Low noise free cooling type Model  130V1 150V1 200V1 250V1 350V1 400V1 450V1 500V1 600V1 700V1 800V1 Cooling capacity(1) kW 114 137 176 243 312 373 404 470 557 636 746 Cooling capacity(2) kW 126 152 196 269 346 414 448 522 619 705 829 Free cooling capacity(3) kW 127 152 197 271 348 416 451 525 622 709 833 Qty. of compressors n. 1 1 1 1 1 1 1 1 1 1 1 Length mm 3600 3600 4355 5170 4980 4980 4980 6490 7480 7480 8470 Width mm 1420 1420 1420 1420 2370 2370 2370 2370 2370 2370 2370 Height mm 2280 2280 2280 2280 2540 2540 2540 2540 2540 2540 2540 Weight kg 1840 1980 2210 2550 3725 4250 5400 5660 6650 7050 8000 Model  400V2 450V2 500V2 600V2 700V2 800V2 1000V2 1200V2 1400V2 1600V2 Cooling capacity(1) kW 366 416 497 557 624 746 941 1115 1271 1493 Cooling capacity(2) kW 407 462 552 619 692 829 1044 1237 1411 1657 Free cooling capacity(3) kW 409 464 554 622 696 833 1049 1244 1418 1665 Qty. of compressors n. 2 2 2 2 2 2 2 2 2 2 Length mm 4980 6490 6490 7480 7480 8470 13780 15760 15760 18440 Width mm 2370 2370 2370 2370 2370 2370 2370 2370 2370 2370 Height mm 2540 2540 2540 2540 2540 2540 2540 2540 2540 2540 Weight kg 4760 5900 6160 7260 7550 8500 11320 13300 14100 16000
  • 26. 26 HYDROCOOL HYDRCOOL/HYDROCOO-HE series is applicable to large-sized data center and all kinds of industrial technology place. It has a wide range cooling capacity, high operating reliability and stability. HYDROCOO-HE is equipped with flooded evaporator, to achieve higher EER, save huge energy and lowering the operation cost. This series adopts screw compressor and flooded evaporator, minimized the unit size and footprint. Standard Full liquid Type Model 250V1 400V1 500V1 600V1 700V1 500V2 800V2 900V2 1000V2 1100V2 1200V2 1300V2 Cooling capacity (1) kW 229.5 406.7 495.1 589.7 736.5 459 804.6 894.7 989.8 1076 1175.6 1320 Cooling capacity (2) kW 238.2 422.2 513.9 612.1 764.5 476.4 835.2 928.7 1027.4 1116.9 1220.3 1370.2 Heating capacity (3) kW 237.5 421.6 511.3 611 763 475 835.8 927.1 1021.6 1115.5 1218.7 1369.1 Qty of compressor n. 1 1 1 1 1 2 2 2 2 2 2 2 Heating capacity of partial heat recycle kw 52.9 86.1 104.1 134.1 160 103.9 172.5 192.1 209.4 227.6 248.7 279.3 Length mm 3385 3385 3385 3415 3475 3900 4100 4160 4160 4160 4160 4450 Width mm 970 970 1060 1060 1060 1160 1160 1160 1160 1300 1540 1540 Height mm 2000 2000 2000 2000 2000 1940 2100 2100 2100 2160 2160 2214 Weight (4) kg 1380 2000 2320 3110 3280 2400 3610 3740 3820 4100 4600 4750 Model 1400V2 1600V2 1800V2 1600V4 1800V4 2000V4 2200V4 2400V4 2600V4 2800V4 3200V4 3600V4 Cooling capacity (1) kW 1470.5 1612.3 1820.6 1609.2 1789.4 1979.6 2125 2357.9 2644.5 2938 3224.6 3641.2 Cooling capacity (2) kW 1526.4 1673.6 1889.8 1670.3 1857.4 2054.8 2233.8 2447.5 2745 3049.6 3347.1 3779.6 Heating capacity (3) kW 1523.1 1669.8 1888.1 1671.5 1854.1 2043.1 2231 2442.7 2740.3 3043.7 3339.6 3776.1 Qty of compressor n. 2 2 2 4 4 4 4 4 4 4 4 4 Heating capacity of partial heat recycle kW 311 338.6 382.3 345 381.7 418.9 455.2 535.6 582.9 635.1 677.2 764.6 Length mm 4510 4510 4510 4100 4160 4160 4160 4160 4450 4510 4510 4510 Width mm 1540 1540 1540 2560 2560 2560 2840 3320 3320 3320 3320 3320 Height mm 2214 2214 2214 2100 2100 2100 2160 2160 2214 2214 2214 2214 Weight (4) kg 4900 5300 5500 7220 7480 7640 8100 9000 9305 9600 10600 11000 (1) Cooling capacity @ evaporator water inlet and outlet temperature 12/7℃, condenser water inlet and outlet temperature 30/35℃; (2) Water source heating pump cooling capacity @ evaporator water inlet and outlet temperature 12/7℃, condenser water inlet and outlet temperature 15/30℃; (3) Water source heating pump heating capacity @ evaporator water inlet and outlet temperature 15/6℃, condenser water inlet and outlet temperature 40/45℃; (4) Exclude the weight of option. Model 300V1 340V1 400V1 450V1 500V1 550V1 600V1 650V1 700V1 800V1 600V2 700V2 800V2 900V2 1000V2 Cooling capacity (1) kW 274.3 321.8 379.3 443.3 502.1 556 581.9 656 720 757.8 548.5 643.5 758.6 886.7 1004.3 Cooling capacity (2) kW 289.6 339.6 400.3 468.4 530.4 587.6 614.7 692.9 761.4 801.4 579.1 679.3 800.6 936.9 1060.7 Heating capacity (3) kW 296.2 348.1 409.9 475.7 537.7 596.6 624.3 702 755 793.5 592.4 696.3 819.7 951.5 1075.4 Qty of compressor n. 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 Heating capacity of partial heat recycle kw 68.6 80.4 94.8 110.8 125.5 139 145.5 164 180 189.5 137.1 160.9 189.7 221.7 251.1 Length mm 3555 3555 3555 3570 3770 3970 3985 3985 3995 3995 4445 4445 4460 4460 4470 Width mm 1160 1160 1160 1240 1240 1240 1280 1320 1380 1380 1240 1240 1320 1380 1440 Height mm 1630 1630 1630 1880 1880 1880 1880 2070 2070 2070 1670 1670 1720 1930 1990 Weight (4) kg 2350 2500 2780 3060 3200 3435 3740 3940 4060 4210 4435 4720 5530 5950 6260 Model 1100V2 1200V2 1300V2 1400V2 1600V2 1800V2 2000V4 2200V4 2400V4 2600V4 2800V4 2000V4 Cooling capacity (1) kw 1111.9 1163.7 1312 1440 1515.6 1773.3 2008.5 2223.8 2327.5 2624 2880 3031.2 Cooling capacity (2) kw 1175.1 1229.3 1385.8 1522.8 1602.8 1873.7 2121.5 2350.2 2458.7 2771.6 3045.6 3205.6 Heating capacity (3) kw 1193.1 1248.7 1404.1 1510 1587 1902.9 2150.8 2386.2 2497.3 2808.1 3020 3174 Qty of compressor n. 2 2 2 2 2 4 4 4 4 4 4 4 Heating capacity of partial heat recycle kw 278 290.9 328 360 378.9 443.3 502.1 556 581.9 656 720 757.8 Length mm 4485 4485 4485 4495 4495 4470 4470 4485 4485 4495 4495 4495 Width mm 1540 1540 1590 1640 1640 2950 2950 2950 2950 2950 2950 2950 Height mm 2040 2040 2180 2230 2230 2480 2540 2640 2710 2760 2780 2780 Weight (4) kg 6950 7410 7810 8020 8350 11900 12520 13900 14820 15620 16040 16700
  • 27. 27 All AIRSYS products are equipped with AIRSYS advanced microcomputer control system. Hardware meets industrial / ICT environment requirements, high reliability, anti-jamming. Control program embodies AIRSY many years’ experience in ICT environment-air conditioner produce, fully consider reliable, energy saving, convenient needs, are the core values embodied AIRSYS products. By micro-controller, a large number of parameters can be set flexibly, including automatic / manual, operating logic selection, parameter calibration, the ON / OFF the designated member. Control system By running status and time records, you can keep abreast of the operational status of the unit, part of the on / off status, running time and other information. Alarm and security alarm information and provide numerous security protection, including restart, current and voltage, phase sequence protection, pressure protection, thermal protection, and so on. There are several ways to achieve remote monitoring, remote setting parameters, upload programs, remote on / off, remote alarm, etc. Remote Control And Monitoring Network The unit can be remote controlled or monitored by many kinds of methods as follows: 3 kinds of local direct cable connection 3 kinds of LAN network connection 4 kinds of wireless network connection N16 N2 N1 N16 N2 N1 N16 N2 N1 Wireless connection types Local area network connection type Ethernet network cable LAN connection 1 LAN connection 2 RS485-RS232 Converter RS485-RS232 Converter Units direct connection type RS485 Bus RS485 Bus RS485 BusRS232 cable RS485-TCP/IP converter with 16 ports Cooling unit & Comm. card Single port RS485-TCP/IP converter Single unit direct connection types GSM Mobile communication network GSM communication network Wireless connection 1 Mobile phone Mobile phone GSM module GSM module Wireless connection 3 Wireless connection 4 Direct connection 1 Direct connection 2 Direct connection 3 Direct connection 4 wireless communication network wireless router Wireless router The computer is installed with TCP/IP card RS485 card RS232 card and IntelliVision plus software RS485 card MODBUS protocol Wireless connection 2 Monitoring Computer
  • 28. Airsys Refrigeration Engineering Technology (Beijing) Co., Ltd. 28, Lu Gu Dong Jie, ShijingshanBeijing, China,100040 Tel:+86-10-6865 6161 Fax:+86-10-6865 2453 Gu'an Airsys Enviroment Technology Company Ltd. P.25, St. West Orient, Gu'an Industry Park, Gu'an County, Langfang City, Hebei Province, China. Tel:+86-10-6865 6161 Fax:+86-10-6865 2453 Shanghai Airserve HVAC Systerm Service Co., Ltd. #7-2,No.658,Daduhe Rd.,Putuo District,Shanghai,China,200333 Tel: +86-21-6245 2626 Fax:+86-21-6245 9622 Airsys Group (HK) Co., Ltd. Room 1305, Carnival Commercial Building, No. 18 Java Road, North Point,Hong Kong Tel: 00852-2711 0511 Fax: 00852-2711 1511 Airsys (UK) Ltd. Oak House Overbrook Lane Knowsley Business Park Liverpool,UK L34 9FB Tel: +44-845 2411007 Fax: +44-151 547 8801 www.air-sys.com Callcenter:+86-400-820-5515