X-Ray Diffraction
Background and Fundamentals
Prof. Thomas Key
School of Materials Engineering

1
Crystalline materials are characterized by
the orderly periodic arrangements of atoms.
The (200) planes
of atoms in NaCl

The (220) planes
of atoms in NaCl

• The unit cell is the basic repeating unit that defines a
crystal.
• Parallel planes of atoms intersecting the unit cell are
used to define directions and distances in the crystal.
– These crystallographic planes are identified by Miller indices.
2
Bragg’s law is a simplistic model to understand
what conditions are required for diffraction.

•

For parallel planes of atoms, with a space dhkl between the planes, constructive
interference only occurs when Bragg’s law is satisfied.
–
–
–

In our diffractometers, the X-ray wavelength λ is fixed.
Consequently, a family of planes produces a diffraction peak only at a specific angle θ.
Additionally, the plane normal must be parallel to the diffraction vector
•
•

•
•

θ
d hkl d hkl

λ = 2d hkl sin θ

θ

Plane normal: the direction perpendicular to a plane of atoms
Diffraction vector: the vector that bisects the angle between the incident and diffracted beam

The space between diffracting planes of atoms determines peak positions.
The peak intensity is determined by what atoms are in the diffracting plane.

3
Our powder diffractometers typically
use the Bragg-Brentano geometry.
Detector
X-ray
tube

Φ

ω

•

θ

2θ

Angles
– The incident angle (ω) is between the X-ray source and the sample.
– The diffracted angle (2θ) is between the incident beam and the detector.
– In plane rotation angle (Φ)

•

In “Coupled 2θ” Measurements:

– The incident angle ω is always ½ of the detector angle 2θ .
– The x-ray source is fixed, the sample rotates at θ °/min and the detector
rotates at 2θ °/min.
4
Coupled 2θ Measurements

X-ray
tube

Detector

Motorized
Source Slits
Φ

ω

•

θ

2θ

In “Coupled 2θ” Measurements:

– The incident angle ω is always ½ of the detector angle 2θ .
– The x-ray source is fixed, the sample rotates at θ °/min and the detector
rotates at 2θ °/min.

•

Angles
– The incident angle (ω) is between the X-ray source and the sample.
– The diffracted angle (2θ) is between the incident beam and the detector.
– In plane rotation angle (Φ)
5
The X-ray Shutter is the most important
safety device on a diffractometer
• X-rays exit the tube through X-ray
transparent Be windows.
• X-Ray safety shutters contain the
beam so that you may work in the
diffractometer without being
exposed to the X-rays.
• Being aware of the status of the
shutters is the most important
factor in working safely with X rays.
6
•
•
•

The wavelength of X rays is determined
by the anode of the X-ray source.

Electrons from the filament strike the target anode, producing
characteristic radiation via the photoelectric effect.
The anode material determines the wavelengths of characteristic radiation.
While we would prefer a monochromatic source, the X-ray beam actually
consists of several characteristic wavelengths of X rays.

K

L
M

7
Why does this sample second set
of peaks at higher 2θ values?
• Hints:

113

– It’s Alumina
– Cu source
– Detector has a single
channel analyzer

Kα1
Kα2

006

8
Diffraction Pattern Collected
Where A Ni Filter Is Used
To Remove Kβ

Kα1

Kα2

What could
W Lα1
this be?
Due to tungsten
contamination

Kβ

E ( keV ) = hυ =

hc 6.02
=
λ λ ( Α)
9
Wavelengths for X-Radiation are
Sometimes Updated
Copper
Anodes

Bearden
(1967)

Holzer et al.
(1997)

Cobalt
Anodes

Bearden
(1967)

Holzer et al.
(1997)

Cu Kα1

1.54056Å

1.540598 Å

Co Kα1

1.788965Å

1.789010 Å

Cu Kα2

1.54439Å

1.544426 Å

Co Kα2

1.792850Å

1.792900 Å

Cu Kβ

1.39220Å

1.392250 Å

Co Kβ

1.62079Å

1.620830 Å

Cr Kα1

2.28970Å

2.289760 Å

Molybdenum
Anodes

Chromium
Anodes

Mo Kα1

0.709300Å

Mo Kα2

0.713590Å

0.713609 Å

Cr Kα2

2.293606Å

2.293663 Å

Mo Kβ

0.632288Å

0.632305 Å

Cr Kβ

2.08487Å

2.084920 Å

•

0.709319 Å

Often quoted values from Cullity (1956) and Bearden, Rev. Mod. Phys. 39
(1967) are incorrect.
– Values from Bearden (1967) are reprinted in international Tables for X-Ray
Crystallography and most XRD textbooks.

•

Most recent values are from Hölzer et al. Phys. Rev. A 56 (1997)
10
Calculating Peak Positions
λ = 2d hkl sin θ

11
Lattice Parameters & Atomic Radii
Body Centered Cubic
(BCC)

4R
a=
3

a

Common BCC Metals

a

–
–
–
–
–

Chromium
Iron (α)
Molybdenum
Tantalum
Tungsten
12
Lattice Parameters & Atomic Radii
(110)

Body Centered Cubic
(BCC)

4R
a=
3

a

Common BCC Metals
–
–
–
–
–

Chromium
Iron (α)
Molybdenum
Tantalum
Tungsten
13
Lattice Parameters & Atomic Radii
Face Centered Cubic
(FCC)
a

a = 2R 2
Common FCC Metals

a

–
–
–
–
–
–
–

Aluminum
Copper
Gold
Lead
Nickel
Platinum
Silver 14
Lattice Parameters & Atomic Radii
(100)

Face Centered Cubic
(FCC)

a = 2R 2
Common FCC Metals
–
–
–
–
–
–
–

Aluminum
Copper
Gold
Lead
Nickel
Platinum
Silver 15
Planes and Family of Planes
<001>

(001)

Cubic

c
(010)

(100)

b

(011)

(110)

(101)

a

(111)

(111)

(111)

(planes)
<directions>
16
Other Families of Planes

17
Higher Order Planes
(Half Planes)

18
Not all Planes Produce Peaks
Peak Intensity
I hkl = I 0pCL P [ Fhkl ]

Structure Factors
2

 Only if [Fhkl]2 ≠0 does a peak appear
N

where
– Io = Intensity of the incident X-ray beam
– p = Multiplicity factor (a function of the
crystallography of the material)

– C = Experimental constant (related to temperature,
absorption, fluorescence, and crystal imperfection).
Temperature factor=e-2M; Absorption factor = A(θ).

– LP = Lorentz-Polarization factor.

Fhkl = ∑ fn exp[ 2π i ( hu n + kv n + lw n ) ]
n =1

– ƒn = atomic scattering factor of atom ‘n’ is a
measure of the scattering efficiency

– u,v,w are the atomic positions in the unit cell
– h,k,l are the Miller indices of the reflection.
– N is number of atoms in the unit cell
 The summation is performed over all atoms in
the unit cell.

These calculations are easily doable for
simple structures
19
Structure Factors: Useful Knowledge
(1)

• Atomic scattering factors vary as a
function of atomic number (Z) and
diffraction angle (θ)
• Values can be looked up in tables
–

(2)

Linear extrapolations are used for
calculating the values between those
listed.

Calculating structure factors involves complex exponential functions. Use the following
relationships to determine the values of the exponential:

20
2. BCC Structure
Consider the BCC lattice with single atoms at each lattice point; its unit cell can be reduced to
two identical atoms. Atom #1 is at 0,0,0 and atom #2 is at ½, ½, ½.

For this case we have
.

.

.

(5)

Note: For atoms of the same type, f1 = f2 = f.
Observations:
(i)
If the sum (h + k + l) = even in Equation (5), Fhkl = 2f and
(ii)
If the sum (h + k + l) = odd in Equation (5), Fhkl = 0 and
Thus, diffractions from BCC planes where h + k + l is odd are of zero intensity. They are
forbidden reflections. These reflections are usually omitted from the reciprocal lattice.

21
3. FCC Structure
The FCC unit cell has four atoms located at (0,0,0), (½,½,0), (½,0,½), and (0, ½,½).

It follows that, for the same kind of atoms, the structure factor the FCC structure is given by the
expression

.

.

.

.

.

(6)

If h, k, and l are all even or all odd (i.e. unmixed) then the sums h + k, h + l, and k + l are all
even integers, and each term in Equation (6) equals 1. Therefore, Fhkl = 4f. However, if h, k, and l
are mixed integers, then Fhkl = f(1+1-2) = 0.

22
Compound Structure Factors
Consider the compound ZnS (sphalerite). Sulphur
atoms occupy FCC sites with zinc atoms
displaced by ¼ ¼ ¼ from these sites. The unit cell
can be reduced to four atoms of sulphur and 4
atoms of zinc.
Consider a general unit cell for this type of
structure. Many important compounds adopt this
structure; examples include ZnS, GaAs, InSb, InP
and (AlGa)As. It can be reduced to 4 atoms of
type A at 000, 0 ½ ½, ½ 0 ½, ½ ½ 0 i.e. in the
FCC position and 4 atoms of type B at the sites ¼
¼ ¼ from the A sites. This can be expressed as:

The structure factors for this structure are:
F=0
F = 4(fA ± ifB)
F = 4(fA - fB)
F = 4(fA + fB)

if h, k, l mixed (just like FCC)
if h, k, l all odd
if h, k, l all even and h+ k+ l = 2n where n=odd (e.g. 200)
if h, k, l all even and h+ k+ l = 2n where n=even (e.g. 400)

23
X-Ray Diffraction Patterns
111

λ = 2d hkl sin θ

200
220

•
•

311

222

BCC or FCC?
Relative intensities determined by:

I hkl = I 0pCL P [ Fhkl ]

2

24
A random polycrystalline sample that contains thousands of
crystallites should exhibit all possible diffraction peaks
200
220

111

222
311

2θ

2θ

2θ

• For every set of planes, there will be a small percentage of crystallites that are properly
oriented to diffract (the plane perpendicular bisects the incident and diffracted beams).
• Basic assumptions of powder diffraction are that for every set of planes there is an equal
number of crystallites that will diffract and that there is a statistically relevant number of
25
crystallites, not just one or two.
Why are peaks missing?
JCPDF# 01-0994

200
220

111

222
311

•The sample is a cut piece of Morton’s Salt
•JCPDF# 01-0994 is supposed to fit it (Sodium Chloride Halite)
26
It’s a single crystal
(a big piece of rock salt)
200
220

111

222
311

2θ

At 27.42 °2θ, Bragg’s law
fulfilled for the (111) planes,
producing a diffraction peak.

The (200) planes would diffract at 31.82
°2θ; however, they are not properly
aligned to produce a diffraction peak

The (222) planes are parallel to the (111)
planes.

27
Questions

28
29
Multiplicity (p) Matters

30
31
32
33
34
35
Example 5

Radiation from a copper source -

Is that enough information?
“Professor my peaks split!”
36
X-radiation for diffraction measurements is
produced by a sealed tube or rotating anode.
• Sealed X-ray tubes tend to
operate at 1.8 to 3 kW.
• Rotating anode X-ray tubes
produce much more flux because
they operate at 9 to 18 kW.
– A rotating anode spins the anode
at 6000 rpm, helping to distribute
heat over a larger area and
therefore allowing the tube to be
run at higher power without
melting the target.

• Both sources generate X rays by
striking the anode target wth an
electron beam from a tungsten
filament.
– The target must be water cooled.
– The target and filament must be
contained in a vacuum.

H2O In

H2O Out

Cu

Be
window

ANODE
Be
window

eXRAYS

XRAYS
FILAMENT
(cathode)

metal

glass
(vacuum)

(vacuum)

AC CURRENT

37
Spectral Contamination in
Diffraction Patterns
Kα1
Kα1

Kα2

Kα2

Kα1

Kα2

• The Kα1 & Kα2 doublet will almost always be present
Kβ

W Lα1

– Very expensive optics can remove the Kα2 line
– Kα1 & Kα2 overlap heavily at low angles and are more
separated at high angles

• W lines form as the tube ages: the W filament
contaminates the target anode and becomes a new Xray source
• W and Kβ lines can be removed38 optics
with
Divergence slits are used to limit the
divergence of the incident X-ray beam.
•

The slits block X-rays that have too
great a divergence.
• The size of the divergence slit
influences peak intensity and peak
shapes.
• Narrow divergence slits:
– reduce the intensity of the X-ray beam
– reduce the length of the X-ray beam
hitting the sample
– produce sharper peaks
• the instrumental resolution is improved so
that closely spaced peaks can be
resolved.

39
Varying Irradiated area of the
sample
• the area of your sample that is illuminated by the
X-ray beam varies as a function of:
– incident angle of X rays
– divergence angle of the X rays

• at low angles, the beam might be wider than
your sample
– “beam spill-off”

40
The constant volume
assumption
• In a polycrystalline sample of ‘infinite’
thickness, the change in the irradiated
area as the incident angle varies is
compensated for by the change in the
penetration depth
• These two factors result in a constant
irradiated volume
– (as area decreases, depth increase; and vice
versa)

• This assumption is important for many
41
aspects of XRPD
divergence is that the length of the
beam illuminating the sample
becomes smaller as the incident
• The length of the
incident angle becomes larger.
beam is
determined by the
divergence slit,
goniometer radius, and
incident angle.
• This should be
considered when
choosing a divergence
slits size:

40.00
35.00
L
I
e 30.00
r
n
r
g 25.00
a
t
d
h 20.00
i
a
15.00
t
m
e
m 10.00
d

2°DS

1°DS

(
)

– if the divergence slit is
too large, the beam
may be significantly
longer than your sample
at low angles
– if the slit is too small,
you may not get enough
intensity from your

185mm Radius Goniometer, XRPD

0.5°DS

5.00

0.15°DS

0.00
0

20

40

60

2Theta (deg)

42

80

100
43
Detectors
• point detectors
– observe one point of space at a time
• slow, but compatible with most/all optics

– scintillation and gas proportional detectors count all
photons, within an energy window, that hit them
– Si(Li) detectors can electronically analyze or filter
wavelengths

• position sensitive detectors
– linear PSDs observe all photons scattered along a
line from 2 to 10° long
– 2D area detectors observe all photons scattered
along a conic section
– gas proportional (gas on wire; microgap anodes)
• limited resolution, issues with deadtime and saturation

– CCD

44
Sources of Error in XRD Data
• Sample Displacement
– occurs when the sample is not on the focusing
circle (or in the center of the goniometer circle)
– The greatest source of errorcosmost data
2s in θ
∆ 2θ = −
(in radians )
– A systematic error:
R

• S is the amount of displacement, R is the goniometer
radius.
• at 28.4° 2theta, s=0.006” will result in a peak shift of
0.08°

– Can be minimized by using a zero background
sample holder
45
Other sources of error
• Axial divergence
– Due to divergence of the X-ray beam in plane with the sample
– creates asymmetric broadening of the peak toward low 2theta
angles
– Creates peak shift: negative below 90° 2theta and positive
above 90°
– Reduced by Soller slits and/or capillary lenses

• Flat specimen error
– The entire surface of a flat specimen cannot lie on the focusing
circle
– Creates asymmetric broadening toward low 2theta angles
– Reduced by small divergence slits; eliminated by parallel-beam
optics

• Poor counting statistics
– The sample is not made up of thousands of randomly oriented
crystallites, as assumed by most analysis techniques
46
– The sample might be textured or have preferred orientation
sample transparency error
• X Rays penetrate into your sample
– the depth of penetration depends on:
• the mass absorption coefficient of your sample
• the incident angle of the X-ray beam

• This produces errors because not all X rays
are diffracting from the same location
– Angular errors and peak asymmetry
– Greatest for organic and low absorbing (low atomic
number) samples

•

sin 2θ
∆ 2θ =
Can be eliminated by using parallel-beam
2 µR
optics or reduced by using a thin sample

µ is the linear mass absorption coefficient for a specific sample

47
Techniques in the XRD SEF
• X-ray Powder Diffraction (XRPD)
• Single Crystal Diffraction (SCD)
• Back-reflection Laue Diffraction (no
acronym)
• Grazing Incidence Angle Diffraction
(GIXD)
• X-ray Reflectivity (XRR)
• Small Angle X-ray Scattering (SAXS)
48
Available Free Software
• GSAS- Rietveld refinement of crystal structures
• FullProf- Rietveld refinement of crystal structures
• Rietan- Rietveld refinement of crystal structures
• PowderCell- crystal visualization and simulated
diffraction patterns
• JCryst- stereograms

49

Weitere ähnliche Inhalte

Was ist angesagt?

Was ist angesagt? (20)

X ray diff lecture 3
X ray diff lecture 3X ray diff lecture 3
X ray diff lecture 3
 
X-ray diffraction technique (xrd)
X-ray diffraction technique  (xrd)X-ray diffraction technique  (xrd)
X-ray diffraction technique (xrd)
 
molecular electronic spectra
molecular electronic spectramolecular electronic spectra
molecular electronic spectra
 
Xrd
XrdXrd
Xrd
 
Crystal sizeanalysis
Crystal sizeanalysisCrystal sizeanalysis
Crystal sizeanalysis
 
Specific Heat Capacity
Specific Heat CapacitySpecific Heat Capacity
Specific Heat Capacity
 
XRD principle and application
XRD principle and applicationXRD principle and application
XRD principle and application
 
1 basics of x ray powder diffraction
1 basics of x ray powder diffraction1 basics of x ray powder diffraction
1 basics of x ray powder diffraction
 
X ray diffraction
X ray diffraction X ray diffraction
X ray diffraction
 
X ray diffraction(xrd) principle and use
X ray diffraction(xrd) principle and useX ray diffraction(xrd) principle and use
X ray diffraction(xrd) principle and use
 
X ray powder diffraction
X ray powder diffractionX ray powder diffraction
X ray powder diffraction
 
Optical band gap measurement by diffuse reflectance spectroscopy (drs)
Optical band gap measurement by diffuse reflectance spectroscopy (drs)Optical band gap measurement by diffuse reflectance spectroscopy (drs)
Optical band gap measurement by diffuse reflectance spectroscopy (drs)
 
Laue method
Laue methodLaue method
Laue method
 
X ray diffraction
X ray diffractionX ray diffraction
X ray diffraction
 
X ray diffraction
X ray diffractionX ray diffraction
X ray diffraction
 
Electron diffraction and Neutron diffraction
Electron diffraction and Neutron diffractionElectron diffraction and Neutron diffraction
Electron diffraction and Neutron diffraction
 
Photoluminescence
PhotoluminescencePhotoluminescence
Photoluminescence
 
Basics of-xrd
Basics of-xrdBasics of-xrd
Basics of-xrd
 
X ray diffraction studies
X ray diffraction studies X ray diffraction studies
X ray diffraction studies
 
Solid state physics lec 1
Solid state physics lec 1Solid state physics lec 1
Solid state physics lec 1
 

Ähnlich wie Xrd lecture 1

Small-angle X-ray Diffraction
Small-angle X-ray Diffraction Small-angle X-ray Diffraction
Small-angle X-ray Diffraction ssuser3eb6b21
 
misinterpretingxrdresults-pres.ppt
misinterpretingxrdresults-pres.pptmisinterpretingxrdresults-pres.ppt
misinterpretingxrdresults-pres.pptkrishnakundu95
 
XRD Advance Application (26 July 2022).pdf
XRD Advance Application (26 July 2022).pdfXRD Advance Application (26 July 2022).pdf
XRD Advance Application (26 July 2022).pdfMaykelManawan
 
Crystal structure analysis
Crystal structure analysisCrystal structure analysis
Crystal structure analysiszoelfalia
 
1.crystal structure using x – ray diffraction
1.crystal structure using  x – ray diffraction1.crystal structure using  x – ray diffraction
1.crystal structure using x – ray diffractionNarayan Behera
 
Khoa học vật liệu đại cương bản tiếng anh.pdf
Khoa học vật liệu đại cương bản tiếng anh.pdfKhoa học vật liệu đại cương bản tiếng anh.pdf
Khoa học vật liệu đại cương bản tiếng anh.pdfNguynTunAnh703819
 
X ray diffraction or braggs diffraction or
X ray diffraction or braggs diffraction orX ray diffraction or braggs diffraction or
X ray diffraction or braggs diffraction orbpati5271
 
XRD-calculations and characterization.pdf
XRD-calculations and characterization.pdfXRD-calculations and characterization.pdf
XRD-calculations and characterization.pdfEmadElsehly
 

Ähnlich wie Xrd lecture 1 (20)

Small-angle X-ray Diffraction
Small-angle X-ray Diffraction Small-angle X-ray Diffraction
Small-angle X-ray Diffraction
 
c.pdf
c.pdfc.pdf
c.pdf
 
Xrd mahfooz
Xrd mahfoozXrd mahfooz
Xrd mahfooz
 
misinterpretingxrdresults-pres.ppt
misinterpretingxrdresults-pres.pptmisinterpretingxrdresults-pres.ppt
misinterpretingxrdresults-pres.ppt
 
Crystallography
CrystallographyCrystallography
Crystallography
 
Packing density
Packing densityPacking density
Packing density
 
Seminar chm804
Seminar chm804Seminar chm804
Seminar chm804
 
XRD Advance Application (26 July 2022).pdf
XRD Advance Application (26 July 2022).pdfXRD Advance Application (26 July 2022).pdf
XRD Advance Application (26 July 2022).pdf
 
X-Ray Topic.ppt
X-Ray Topic.pptX-Ray Topic.ppt
X-Ray Topic.ppt
 
Crystal structure analysis
Crystal structure analysisCrystal structure analysis
Crystal structure analysis
 
Crystal defects
Crystal defectsCrystal defects
Crystal defects
 
Crystal field theory
Crystal field theory   Crystal field theory
Crystal field theory
 
Xray diffraction
Xray diffractionXray diffraction
Xray diffraction
 
1.crystal structure using x – ray diffraction
1.crystal structure using  x – ray diffraction1.crystal structure using  x – ray diffraction
1.crystal structure using x – ray diffraction
 
lecture4.pdf
lecture4.pdflecture4.pdf
lecture4.pdf
 
Khoa học vật liệu đại cương bản tiếng anh.pdf
Khoa học vật liệu đại cương bản tiếng anh.pdfKhoa học vật liệu đại cương bản tiếng anh.pdf
Khoa học vật liệu đại cương bản tiếng anh.pdf
 
X ray diffraction or braggs diffraction or
X ray diffraction or braggs diffraction orX ray diffraction or braggs diffraction or
X ray diffraction or braggs diffraction or
 
XRD-calculations and characterization.pdf
XRD-calculations and characterization.pdfXRD-calculations and characterization.pdf
XRD-calculations and characterization.pdf
 
263 4.pdf
263 4.pdf263 4.pdf
263 4.pdf
 
263 4.pdf
263 4.pdf263 4.pdf
263 4.pdf
 

Kürzlich hochgeladen

TrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
TrustArc Webinar - Stay Ahead of US State Data Privacy Law DevelopmentsTrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
TrustArc Webinar - Stay Ahead of US State Data Privacy Law DevelopmentsTrustArc
 
Workshop - Best of Both Worlds_ Combine KG and Vector search for enhanced R...
Workshop - Best of Both Worlds_ Combine  KG and Vector search for  enhanced R...Workshop - Best of Both Worlds_ Combine  KG and Vector search for  enhanced R...
Workshop - Best of Both Worlds_ Combine KG and Vector search for enhanced R...Neo4j
 
HTML Injection Attacks: Impact and Mitigation Strategies
HTML Injection Attacks: Impact and Mitigation StrategiesHTML Injection Attacks: Impact and Mitigation Strategies
HTML Injection Attacks: Impact and Mitigation StrategiesBoston Institute of Analytics
 
Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...Enterprise Knowledge
 
Strategies for Landing an Oracle DBA Job as a Fresher
Strategies for Landing an Oracle DBA Job as a FresherStrategies for Landing an Oracle DBA Job as a Fresher
Strategies for Landing an Oracle DBA Job as a FresherRemote DBA Services
 
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...DianaGray10
 
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024The Digital Insurer
 
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptxHampshireHUG
 
TrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
TrustArc Webinar - Unlock the Power of AI-Driven Data DiscoveryTrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
TrustArc Webinar - Unlock the Power of AI-Driven Data DiscoveryTrustArc
 
A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)Gabriella Davis
 
Scaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organizationScaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organizationRadu Cotescu
 
A Year of the Servo Reboot: Where Are We Now?
A Year of the Servo Reboot: Where Are We Now?A Year of the Servo Reboot: Where Are We Now?
A Year of the Servo Reboot: Where Are We Now?Igalia
 
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot TakeoffStrategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoffsammart93
 
presentation ICT roal in 21st century education
presentation ICT roal in 21st century educationpresentation ICT roal in 21st century education
presentation ICT roal in 21st century educationjfdjdjcjdnsjd
 
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobe
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, AdobeApidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobe
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobeapidays
 
Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024The Digital Insurer
 
How to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerHow to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerThousandEyes
 
Boost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivityBoost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivityPrincipled Technologies
 
Advantages of Hiring UIUX Design Service Providers for Your Business
Advantages of Hiring UIUX Design Service Providers for Your BusinessAdvantages of Hiring UIUX Design Service Providers for Your Business
Advantages of Hiring UIUX Design Service Providers for Your BusinessPixlogix Infotech
 

Kürzlich hochgeladen (20)

TrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
TrustArc Webinar - Stay Ahead of US State Data Privacy Law DevelopmentsTrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
TrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
 
Workshop - Best of Both Worlds_ Combine KG and Vector search for enhanced R...
Workshop - Best of Both Worlds_ Combine  KG and Vector search for  enhanced R...Workshop - Best of Both Worlds_ Combine  KG and Vector search for  enhanced R...
Workshop - Best of Both Worlds_ Combine KG and Vector search for enhanced R...
 
HTML Injection Attacks: Impact and Mitigation Strategies
HTML Injection Attacks: Impact and Mitigation StrategiesHTML Injection Attacks: Impact and Mitigation Strategies
HTML Injection Attacks: Impact and Mitigation Strategies
 
Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...
 
Strategies for Landing an Oracle DBA Job as a Fresher
Strategies for Landing an Oracle DBA Job as a FresherStrategies for Landing an Oracle DBA Job as a Fresher
Strategies for Landing an Oracle DBA Job as a Fresher
 
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
Connector Corner: Accelerate revenue generation using UiPath API-centric busi...
 
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
 
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
 
TrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
TrustArc Webinar - Unlock the Power of AI-Driven Data DiscoveryTrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
TrustArc Webinar - Unlock the Power of AI-Driven Data Discovery
 
A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)
 
Scaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organizationScaling API-first – The story of a global engineering organization
Scaling API-first – The story of a global engineering organization
 
A Year of the Servo Reboot: Where Are We Now?
A Year of the Servo Reboot: Where Are We Now?A Year of the Servo Reboot: Where Are We Now?
A Year of the Servo Reboot: Where Are We Now?
 
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot TakeoffStrategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
 
presentation ICT roal in 21st century education
presentation ICT roal in 21st century educationpresentation ICT roal in 21st century education
presentation ICT roal in 21st century education
 
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobe
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, AdobeApidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobe
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobe
 
Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024
 
How to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected WorkerHow to Troubleshoot Apps for the Modern Connected Worker
How to Troubleshoot Apps for the Modern Connected Worker
 
Boost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivityBoost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivity
 
Advantages of Hiring UIUX Design Service Providers for Your Business
Advantages of Hiring UIUX Design Service Providers for Your BusinessAdvantages of Hiring UIUX Design Service Providers for Your Business
Advantages of Hiring UIUX Design Service Providers for Your Business
 
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
 

Xrd lecture 1

  • 1. X-Ray Diffraction Background and Fundamentals Prof. Thomas Key School of Materials Engineering 1
  • 2. Crystalline materials are characterized by the orderly periodic arrangements of atoms. The (200) planes of atoms in NaCl The (220) planes of atoms in NaCl • The unit cell is the basic repeating unit that defines a crystal. • Parallel planes of atoms intersecting the unit cell are used to define directions and distances in the crystal. – These crystallographic planes are identified by Miller indices. 2
  • 3. Bragg’s law is a simplistic model to understand what conditions are required for diffraction. • For parallel planes of atoms, with a space dhkl between the planes, constructive interference only occurs when Bragg’s law is satisfied. – – – In our diffractometers, the X-ray wavelength λ is fixed. Consequently, a family of planes produces a diffraction peak only at a specific angle θ. Additionally, the plane normal must be parallel to the diffraction vector • • • • θ d hkl d hkl λ = 2d hkl sin θ θ Plane normal: the direction perpendicular to a plane of atoms Diffraction vector: the vector that bisects the angle between the incident and diffracted beam The space between diffracting planes of atoms determines peak positions. The peak intensity is determined by what atoms are in the diffracting plane. 3
  • 4. Our powder diffractometers typically use the Bragg-Brentano geometry. Detector X-ray tube Φ ω • θ 2θ Angles – The incident angle (ω) is between the X-ray source and the sample. – The diffracted angle (2θ) is between the incident beam and the detector. – In plane rotation angle (Φ) • In “Coupled 2θ” Measurements: – The incident angle ω is always ½ of the detector angle 2θ . – The x-ray source is fixed, the sample rotates at θ °/min and the detector rotates at 2θ °/min. 4
  • 5. Coupled 2θ Measurements X-ray tube Detector Motorized Source Slits Φ ω • θ 2θ In “Coupled 2θ” Measurements: – The incident angle ω is always ½ of the detector angle 2θ . – The x-ray source is fixed, the sample rotates at θ °/min and the detector rotates at 2θ °/min. • Angles – The incident angle (ω) is between the X-ray source and the sample. – The diffracted angle (2θ) is between the incident beam and the detector. – In plane rotation angle (Φ) 5
  • 6. The X-ray Shutter is the most important safety device on a diffractometer • X-rays exit the tube through X-ray transparent Be windows. • X-Ray safety shutters contain the beam so that you may work in the diffractometer without being exposed to the X-rays. • Being aware of the status of the shutters is the most important factor in working safely with X rays. 6
  • 7. • • • The wavelength of X rays is determined by the anode of the X-ray source. Electrons from the filament strike the target anode, producing characteristic radiation via the photoelectric effect. The anode material determines the wavelengths of characteristic radiation. While we would prefer a monochromatic source, the X-ray beam actually consists of several characteristic wavelengths of X rays. K L M 7
  • 8. Why does this sample second set of peaks at higher 2θ values? • Hints: 113 – It’s Alumina – Cu source – Detector has a single channel analyzer Kα1 Kα2 006 8
  • 9. Diffraction Pattern Collected Where A Ni Filter Is Used To Remove Kβ Kα1 Kα2 What could W Lα1 this be? Due to tungsten contamination Kβ E ( keV ) = hυ = hc 6.02 = λ λ ( Α) 9
  • 10. Wavelengths for X-Radiation are Sometimes Updated Copper Anodes Bearden (1967) Holzer et al. (1997) Cobalt Anodes Bearden (1967) Holzer et al. (1997) Cu Kα1 1.54056Å 1.540598 Å Co Kα1 1.788965Å 1.789010 Å Cu Kα2 1.54439Å 1.544426 Å Co Kα2 1.792850Å 1.792900 Å Cu Kβ 1.39220Å 1.392250 Å Co Kβ 1.62079Å 1.620830 Å Cr Kα1 2.28970Å 2.289760 Å Molybdenum Anodes Chromium Anodes Mo Kα1 0.709300Å Mo Kα2 0.713590Å 0.713609 Å Cr Kα2 2.293606Å 2.293663 Å Mo Kβ 0.632288Å 0.632305 Å Cr Kβ 2.08487Å 2.084920 Å • 0.709319 Å Often quoted values from Cullity (1956) and Bearden, Rev. Mod. Phys. 39 (1967) are incorrect. – Values from Bearden (1967) are reprinted in international Tables for X-Ray Crystallography and most XRD textbooks. • Most recent values are from Hölzer et al. Phys. Rev. A 56 (1997) 10
  • 11. Calculating Peak Positions λ = 2d hkl sin θ 11
  • 12. Lattice Parameters & Atomic Radii Body Centered Cubic (BCC) 4R a= 3 a Common BCC Metals a – – – – – Chromium Iron (α) Molybdenum Tantalum Tungsten 12
  • 13. Lattice Parameters & Atomic Radii (110) Body Centered Cubic (BCC) 4R a= 3 a Common BCC Metals – – – – – Chromium Iron (α) Molybdenum Tantalum Tungsten 13
  • 14. Lattice Parameters & Atomic Radii Face Centered Cubic (FCC) a a = 2R 2 Common FCC Metals a – – – – – – – Aluminum Copper Gold Lead Nickel Platinum Silver 14
  • 15. Lattice Parameters & Atomic Radii (100) Face Centered Cubic (FCC) a = 2R 2 Common FCC Metals – – – – – – – Aluminum Copper Gold Lead Nickel Platinum Silver 15
  • 16. Planes and Family of Planes <001> (001) Cubic c (010) (100) b (011) (110) (101) a (111) (111) (111) (planes) <directions> 16
  • 17. Other Families of Planes 17
  • 19. Not all Planes Produce Peaks Peak Intensity I hkl = I 0pCL P [ Fhkl ] Structure Factors 2  Only if [Fhkl]2 ≠0 does a peak appear N where – Io = Intensity of the incident X-ray beam – p = Multiplicity factor (a function of the crystallography of the material) – C = Experimental constant (related to temperature, absorption, fluorescence, and crystal imperfection). Temperature factor=e-2M; Absorption factor = A(θ). – LP = Lorentz-Polarization factor. Fhkl = ∑ fn exp[ 2π i ( hu n + kv n + lw n ) ] n =1 – ƒn = atomic scattering factor of atom ‘n’ is a measure of the scattering efficiency – u,v,w are the atomic positions in the unit cell – h,k,l are the Miller indices of the reflection. – N is number of atoms in the unit cell  The summation is performed over all atoms in the unit cell. These calculations are easily doable for simple structures 19
  • 20. Structure Factors: Useful Knowledge (1) • Atomic scattering factors vary as a function of atomic number (Z) and diffraction angle (θ) • Values can be looked up in tables – (2) Linear extrapolations are used for calculating the values between those listed. Calculating structure factors involves complex exponential functions. Use the following relationships to determine the values of the exponential: 20
  • 21. 2. BCC Structure Consider the BCC lattice with single atoms at each lattice point; its unit cell can be reduced to two identical atoms. Atom #1 is at 0,0,0 and atom #2 is at ½, ½, ½. For this case we have . . . (5) Note: For atoms of the same type, f1 = f2 = f. Observations: (i) If the sum (h + k + l) = even in Equation (5), Fhkl = 2f and (ii) If the sum (h + k + l) = odd in Equation (5), Fhkl = 0 and Thus, diffractions from BCC planes where h + k + l is odd are of zero intensity. They are forbidden reflections. These reflections are usually omitted from the reciprocal lattice. 21
  • 22. 3. FCC Structure The FCC unit cell has four atoms located at (0,0,0), (½,½,0), (½,0,½), and (0, ½,½). It follows that, for the same kind of atoms, the structure factor the FCC structure is given by the expression . . . . . (6) If h, k, and l are all even or all odd (i.e. unmixed) then the sums h + k, h + l, and k + l are all even integers, and each term in Equation (6) equals 1. Therefore, Fhkl = 4f. However, if h, k, and l are mixed integers, then Fhkl = f(1+1-2) = 0. 22
  • 23. Compound Structure Factors Consider the compound ZnS (sphalerite). Sulphur atoms occupy FCC sites with zinc atoms displaced by ¼ ¼ ¼ from these sites. The unit cell can be reduced to four atoms of sulphur and 4 atoms of zinc. Consider a general unit cell for this type of structure. Many important compounds adopt this structure; examples include ZnS, GaAs, InSb, InP and (AlGa)As. It can be reduced to 4 atoms of type A at 000, 0 ½ ½, ½ 0 ½, ½ ½ 0 i.e. in the FCC position and 4 atoms of type B at the sites ¼ ¼ ¼ from the A sites. This can be expressed as: The structure factors for this structure are: F=0 F = 4(fA ± ifB) F = 4(fA - fB) F = 4(fA + fB) if h, k, l mixed (just like FCC) if h, k, l all odd if h, k, l all even and h+ k+ l = 2n where n=odd (e.g. 200) if h, k, l all even and h+ k+ l = 2n where n=even (e.g. 400) 23
  • 24. X-Ray Diffraction Patterns 111 λ = 2d hkl sin θ 200 220 • • 311 222 BCC or FCC? Relative intensities determined by: I hkl = I 0pCL P [ Fhkl ] 2 24
  • 25. A random polycrystalline sample that contains thousands of crystallites should exhibit all possible diffraction peaks 200 220 111 222 311 2θ 2θ 2θ • For every set of planes, there will be a small percentage of crystallites that are properly oriented to diffract (the plane perpendicular bisects the incident and diffracted beams). • Basic assumptions of powder diffraction are that for every set of planes there is an equal number of crystallites that will diffract and that there is a statistically relevant number of 25 crystallites, not just one or two.
  • 26. Why are peaks missing? JCPDF# 01-0994 200 220 111 222 311 •The sample is a cut piece of Morton’s Salt •JCPDF# 01-0994 is supposed to fit it (Sodium Chloride Halite) 26
  • 27. It’s a single crystal (a big piece of rock salt) 200 220 111 222 311 2θ At 27.42 °2θ, Bragg’s law fulfilled for the (111) planes, producing a diffraction peak. The (200) planes would diffract at 31.82 °2θ; however, they are not properly aligned to produce a diffraction peak The (222) planes are parallel to the (111) planes. 27
  • 29. 29
  • 31. 31
  • 32. 32
  • 33. 33
  • 34. 34
  • 35. 35
  • 36. Example 5 Radiation from a copper source - Is that enough information? “Professor my peaks split!” 36
  • 37. X-radiation for diffraction measurements is produced by a sealed tube or rotating anode. • Sealed X-ray tubes tend to operate at 1.8 to 3 kW. • Rotating anode X-ray tubes produce much more flux because they operate at 9 to 18 kW. – A rotating anode spins the anode at 6000 rpm, helping to distribute heat over a larger area and therefore allowing the tube to be run at higher power without melting the target. • Both sources generate X rays by striking the anode target wth an electron beam from a tungsten filament. – The target must be water cooled. – The target and filament must be contained in a vacuum. H2O In H2O Out Cu Be window ANODE Be window eXRAYS XRAYS FILAMENT (cathode) metal glass (vacuum) (vacuum) AC CURRENT 37
  • 38. Spectral Contamination in Diffraction Patterns Kα1 Kα1 Kα2 Kα2 Kα1 Kα2 • The Kα1 & Kα2 doublet will almost always be present Kβ W Lα1 – Very expensive optics can remove the Kα2 line – Kα1 & Kα2 overlap heavily at low angles and are more separated at high angles • W lines form as the tube ages: the W filament contaminates the target anode and becomes a new Xray source • W and Kβ lines can be removed38 optics with
  • 39. Divergence slits are used to limit the divergence of the incident X-ray beam. • The slits block X-rays that have too great a divergence. • The size of the divergence slit influences peak intensity and peak shapes. • Narrow divergence slits: – reduce the intensity of the X-ray beam – reduce the length of the X-ray beam hitting the sample – produce sharper peaks • the instrumental resolution is improved so that closely spaced peaks can be resolved. 39
  • 40. Varying Irradiated area of the sample • the area of your sample that is illuminated by the X-ray beam varies as a function of: – incident angle of X rays – divergence angle of the X rays • at low angles, the beam might be wider than your sample – “beam spill-off” 40
  • 41. The constant volume assumption • In a polycrystalline sample of ‘infinite’ thickness, the change in the irradiated area as the incident angle varies is compensated for by the change in the penetration depth • These two factors result in a constant irradiated volume – (as area decreases, depth increase; and vice versa) • This assumption is important for many 41 aspects of XRPD
  • 42. divergence is that the length of the beam illuminating the sample becomes smaller as the incident • The length of the incident angle becomes larger. beam is determined by the divergence slit, goniometer radius, and incident angle. • This should be considered when choosing a divergence slits size: 40.00 35.00 L I e 30.00 r n r g 25.00 a t d h 20.00 i a 15.00 t m e m 10.00 d 2°DS 1°DS ( ) – if the divergence slit is too large, the beam may be significantly longer than your sample at low angles – if the slit is too small, you may not get enough intensity from your 185mm Radius Goniometer, XRPD 0.5°DS 5.00 0.15°DS 0.00 0 20 40 60 2Theta (deg) 42 80 100
  • 43. 43
  • 44. Detectors • point detectors – observe one point of space at a time • slow, but compatible with most/all optics – scintillation and gas proportional detectors count all photons, within an energy window, that hit them – Si(Li) detectors can electronically analyze or filter wavelengths • position sensitive detectors – linear PSDs observe all photons scattered along a line from 2 to 10° long – 2D area detectors observe all photons scattered along a conic section – gas proportional (gas on wire; microgap anodes) • limited resolution, issues with deadtime and saturation – CCD 44
  • 45. Sources of Error in XRD Data • Sample Displacement – occurs when the sample is not on the focusing circle (or in the center of the goniometer circle) – The greatest source of errorcosmost data 2s in θ ∆ 2θ = − (in radians ) – A systematic error: R • S is the amount of displacement, R is the goniometer radius. • at 28.4° 2theta, s=0.006” will result in a peak shift of 0.08° – Can be minimized by using a zero background sample holder 45
  • 46. Other sources of error • Axial divergence – Due to divergence of the X-ray beam in plane with the sample – creates asymmetric broadening of the peak toward low 2theta angles – Creates peak shift: negative below 90° 2theta and positive above 90° – Reduced by Soller slits and/or capillary lenses • Flat specimen error – The entire surface of a flat specimen cannot lie on the focusing circle – Creates asymmetric broadening toward low 2theta angles – Reduced by small divergence slits; eliminated by parallel-beam optics • Poor counting statistics – The sample is not made up of thousands of randomly oriented crystallites, as assumed by most analysis techniques 46 – The sample might be textured or have preferred orientation
  • 47. sample transparency error • X Rays penetrate into your sample – the depth of penetration depends on: • the mass absorption coefficient of your sample • the incident angle of the X-ray beam • This produces errors because not all X rays are diffracting from the same location – Angular errors and peak asymmetry – Greatest for organic and low absorbing (low atomic number) samples • sin 2θ ∆ 2θ = Can be eliminated by using parallel-beam 2 µR optics or reduced by using a thin sample µ is the linear mass absorption coefficient for a specific sample 47
  • 48. Techniques in the XRD SEF • X-ray Powder Diffraction (XRPD) • Single Crystal Diffraction (SCD) • Back-reflection Laue Diffraction (no acronym) • Grazing Incidence Angle Diffraction (GIXD) • X-ray Reflectivity (XRR) • Small Angle X-ray Scattering (SAXS) 48
  • 49. Available Free Software • GSAS- Rietveld refinement of crystal structures • FullProf- Rietveld refinement of crystal structures • Rietan- Rietveld refinement of crystal structures • PowderCell- crystal visualization and simulated diffraction patterns • JCryst- stereograms 49

Hinweis der Redaktion

  1. &lt;number&gt; draw the diffraction vector on this slide, or make a second slide explicitly illustrating the diffraction vector
  2. K alpha 1 and K alpha 2 overlap heavily at low angles and are easier to discriminate at high angles.
  3. &lt;number&gt; K alpha 1 and K alpha 2 overlap heavily at low angles and are easier to discriminate at high angles.