SlideShare ist ein Scribd-Unternehmen logo
1 von 33
Bozzini’s “Lichtleiter” 
The “Lichtleiter” was made from an 
aluminum tube. The tube was illuminated 
by a wax candle and had mirrors fitted to 
it in order to reflect the images. 
Bozzini published his invention in 1806 in 
the Hufeland’s Journal of Practical 
Medicine, Volume 24, under the title 
“Light Conductor, An Invention for the 
Viewing of Internal Parts and Diseases 
with Illustration.” 
Incidentally, Bozzini was censured for 
“undue curiosity” by the Medical Faculty 
of Vienna for this invention. (Courtesy of 
Olympus Austria,
Antoine Jean Desormeaux 
Antoine Jean Desormeaux (1815–1894), a French 
Surgeon, was the first to introduce the Bozzini’s 
“Lichtleiter” into a patient. In 1853, he further 
developed the Lichtleiter and termed his device 
the “Endoscope.” It was the first time this term 
was used in history. 
Desormeaux presented the endoscope in 1865 to 
the Academy in Paris. He even used his endoscope 
to examine the stomach; but due to an insufficient 
light source he was not quite successful. 
(Copyright Verger-Kuhnke AB. The life of Philipp 
Bozzini (1773-1809), an idealist of endoscopy. Actas 
Urol Esp. 2007;31:437-444)
Desormeaux’s “Endoscope” 
Desormeaux’s endoscope used as a light source a 
kerosene lamp Berning alcohol and turpentine, 
with a chimney to enhance the flame and a lens to 
condense the beam to a narrower area to achieve a 
brighter spot. 
He used this instrument to examine the urethra 
and bladder. 
As might have been expected, burns were the 
major complication of these procedures. 
Interestingly, he thought of using electricity but 
felt it unsafe. 
(Courtesy of Olympus Austria, Vienna, Austria)
Johannes Freiherr 
surgeon of Polish-Lithuanian descent born in 
Bukowina, Romania, constructed the first rigid 
endoscope in 1880 and was the first to use 
Edison’s light bulb for his gastroscope in 
practice. 
He modified the instrument so that it could be 
angled by 30Åã near to its lower third to 
achieve better visualization. 
He added a separate channel for air 
insufflation. In one of the first interventional 
endoscopic procedures, he pushed a large 
swallowed bone from the esophagus into the 
stomach, thus avoiding surgery. (Copyright: 
surgeon in the evolution of flexible endoscopy. 
Surg 
Endosc 2007: 21; 838-853 Springer Verlag)
Georg Kelling (1866–1945), a German 
physician 
from Dresden, was introduced to 
endoscopy and gastrointestinal surgery 
when he worked with Professor Mikulicz- 
Radecki at the Royal Surgical Clinic in 
Breslau, Germany. In with the help of 
Nitze’s cystoscope, and coined this 
laparoscopic examination “celioscopy.” 
He used air filtered through sterile cotton 
to create pneumoperitoneum in dogs. For 
insufflation he used a trocar Developed by 
Alfred Fiedler, an internist from Dresden. 
(Copyright: Hatzinger M: Georg Kelling 
(1866–1945) Der Erfinder der modernen 
Laparoskopie. Urologe A 2006; 45 (7):868-71 
Springer Verlag)
Harold Horace Hopkins 
Hopkins (1918–1994) obtained a degree in physics and 
mathematics at Leicester University in 1939. After the war, 
in 1947, Hopkins became a research fellow at Imperial 
College, London, UK. 
Hopkins invented the rigid rod-lens system for scopes, 
which allows double light transmission, requires short and 
thin spacer tubes, and gives a larger and clearer aperture. 
He filed a patent for the rod-lens system in 1959. 
However, the English and American companies to whom he 
offered the system displayed little interest. 
The situation changed however in 1965 when Professor 
George Berci, who recognized the potential of this 
invention, introduced Hopkins to Karl Storz to manufacture 
the scopes. (Courtesy of William P. Didusch Center for 
Urologic History, American Urological Association, MD, 
USA)
Kurt Karl Stephan Semm 
Kurt Karl Stephan Semm (1927–2003) was born in Munich, 
Germany, where he also studied medicine at the Ludwigs- 
Maximillian University. In 1958, he wrote his medical 
thesis under the guidance of Nobelmlaureate Adolf 
Butenandt. Semm began his career in gynecology under 
Professor Fikentscher in Munich. In 1970s, as the Head of 
Gynecology in Kiel, introduced an; 
1- Automatic insufflation device capable of monitoring 
intra-abdominal pressures, 
2- Endoscopic loop sutures, 
3-Extra- and intracorporeal suturing techniques. 
4-Created the pelvi- trainer. He performed the first 
laparoscopic appendectomy 
in 1982. (Courtesy of Monika Bals-Pratsch MD, 
Zentrum für Gyn.kologie, Universit.t Regensburg, 
Germany)
Anatomy of a Rigid Scope
 Central to the instrumentation is the scope. Its 
backbone is the rod lens system designed by 
Hopkins. 
 The shaft of scopes houses both light fibers 
 and viewing optics. 
 The viewing optic consist of three distinct 
parts: 
o The objective lens, 
o Rod lenses, 
o ocular lens.
Field of View 
The field of view (also field of vision) 
is the angular extent of the 
observable area that is seen at any 
given moment. The field of view in 
scopes for endoscopic surgery can 
vary from 600 to 820 depending up 
on the type of instrument. Wider 
angles of view provide a greater 
depth of field in the image with 
better utilization of illumination. A 
smaller field of view allows the 
scope to be farther from the tissue, 
for the same to be observed.
Angle of View 
The angle of view in scopes can vary with 
respect to the central axis view are 
designated as 00 and provide a straight 
view of the structure in question. Scopes 
are also available with a 50, 250, 300, 450, 
and even 700 angle of view, allowing 
utilization of the scopes much as a 
periscope. The off-axis scopes enable one 
to observe 
down into the gutters and up the anterior 
abdominal wall as well as sideways. Off-axis 
scopes are difficult to work with; however, 
they provide an excellent means of 
obtaining close inspection of tissues 
at difficult angles and positions.
Scope Size and Screen Image 
The decrease in the size of scopes was an important 
factor in the advancement of minimally invasive 
surgery in the pediatric age group. Although scopes 
are available in sizes from 1.9 mm to 12 mm in 
diameter, the majority of the procedures are 
performed using 5- or 10-mm scopes. 
When compared to the reduced view obtained in the 
previous generation of scopes (left), modern5-mm, 
full-screen scopes provide a bright, distortion- free, 
full-screen image (right). In addition, the image size 
in modern 5-mm scope is equivalent to that obtained 
by the previous-generation 
10-mm scope. (Courtesy of Richard Wolf, Knittlingen, 
Germany)
Charge Coupled Device (CCD) 
Video Cameras Scope cameras are available in either 
single-chip 
three-chip versions (one chip offers 300,000 pixels/cm2). 
In single-chip CCD cameras, all the three primary colors (red, 
blue and green) are sensed by a single chip. In three-chip CCD 
cameras, there are three chips for separate capture and 
processing of the primary colors. 
Single-chip CCD cameras produce images of 450 lines/inch 
resolution and are ideal for outpatient surgery. On the other 
hand, three-chip CCD cameras have high fidelity with 
unprecedented color reproduction to produce images of 750 
lines/ inch resolution that can be viewed optimally on flat-panel 
screens and are best suited for endoscopic surgery. 
(Courtesy of RichardWolf, Knittlingen , Germany) 
Light source: 
Light-Source Generators and Transmission Pathways There 
are two commonly utilized light sources: halogen and xenon. 
A schematic overview of light transmission is outlined12
The Concept of White Balancing 
White balancing should be performed before 
inserting the camera inside the abdominal cavity. This 
is necessary before commencing surgery to diminish 
the added impurities of color that may be introduced 
due to a variety of reasons such as: 
(1) voltage difference, 
(2) staining of the tip by cleaners, 
(3) scratches and wear of the eyepiece. 
White balancing is achieved by keeping a white 
object in front of the scope and activating the 
appropriate button on the video system or camera. 
The camera senses the white object as its reference 
to adjust all of the primary colors (red, blueand 
green). (Courtesy of Richard Wolf, Knittlingen, 
Germany)
A three-CCD camera is a camera whose 
imaging system uses three separate charge-coupled 
devices (CCDs), 
each one taking a separate measurement of 
the primary colors, red, green, or blue light. 
Light coming into the lens is split by a 
trichroic prism assembly, which directs the 
appropriate wavelength ranges of light to 
their respective CCDs. 
The system is employed by still cameras, 
telecine systems, professional video cameras 
and some prosumer video cameras.
Rods and Cones 
The retina contains two types of photoreceptors, 
Rods 
cones. 
The rods are more numerous, some 120 million, and are more sensitive than the 
cones 
they are not sensitive to color. The 6 to 7 million cones provide the eye's color 
sensitivity and they are much more concentrated in the central yellow spot known as 
the macula. In the center of that region is the " fovea centralis ", a 0.3 mm diameter 
rod-free area with very thin, densely packed cones. 
The experimental evidence suggests that among the cones there are three different 
types of color reception. Response curves for the three types of cones have been 
determined. Since the perception of color depends on the firing of these three types 
of nerve cells, it follows that visible color can be mapped in terms of three 
numbers called tristimulus values. 
Color perception has been successfully modeled in terms of tristimulus values and 
mapped on the CIE chromaticity diagram.
Rods Do Not See Red! 
The light response of the rods peaks sharply in the blue; they respond very little 
to red light. This leads to some interesting phenomena: 
Red rose at twilight: In bright light, the color-sensitive cones are predominant 
and we see a brilliant red rose with somewhat more subdued green leaves. But 
at twilight, the less-sensitive cones begin to shut down for the night, and most 
of the vision comes from the rods. The rods pick up the green from the leaves 
much more strongly than the red from the petals, so the green leaves become 
brighter than the red petals! 
The ship captain has red instrument lights. Since the rods do not respond to red, 
the captain can gain full dark-adapted vision with the rods with which to watch 
for icebergs and other obstacles outside. It would be undesirable to examine 
anything with white light even for a moment, because the attainment of 
optimum night-vision may take up to a half-hour. Red lights do not spoil it. 
These phenomena arise from the nature of the rod-dominated dark-adapted 
vision, called scotopic vision.
Cone Details 
Current understanding is that the 6 to 7 million cones can be divided 
into "red" cones (64%), "green" cones (32%), and "blue" cones (2%) 
based on measured response curves. They provide the eye's color 
sensitivity. The green and red cones are concentrated in the fovea 
centralis . The "blue" cones have the highest sensitivity and are 
mostly found outside the fovea, leading to some distinctions in the 
eye's blue perception. 
The cones are less sensitive to light than the rods, as shown a typical 
day-night comparison. The daylight vision (cone vision) adapts much 
more rapidly to changing light levels, adjusting to a change like 
coming indoors out of sunlight in a few seconds. Like all neurons, the 
cones fire to produce an electrical impulse on the nerve fiber and 
then must reset to fire again. The light adaption is thought to occur 
by adjusting this reset time. 
The cones are responsible for all high resolution vision. The eye 
moves continually to keep the light from the object of interest falling 
on the fovea centralis where the bulk of the cones reside.
The combination of the three sensors can be done in the 
following ways: 
Composite sampling, where the three sensors are perfectly 
aligned to avoid any color artifact when recombining the 
information from the three color planes 
Pixel shifting, where the three sensors are shifted by a fraction 
of a pixel. After recombining the information from the three 
sensors, higher spatial resolution can be achieved. 
Pixel shifting can be horizontal only to provide higher 
horizontal resolution in standard resolution camera, or 
horizontal and vertical to provide high resolution image using 
standard resolution imager for example. The alignment of the 
three sensors can be achieved by micro mechanical 
movements of the sensors relative to each other. 
Arbitrary alignment, where the random alignment errors due 
to the optics are comparable to or larger than the pixel size.
Compared to cameras with only one CCD, three-CCD cameras 
generally provide superior image quality through enhanced 
resolution and lower noise. 
By taking separate readings of red, green, and blue values for each 
pixel, 
three-CCD cameras achieve much better precision than single-CCD 
cameras. 
By contrast, almost all single-CCD cameras use a Bayer filter, which 
allows them to detect only one-third of the color information for 
each pixel. 
The other two-thirds must be interpolated with a demosaicing 
algorithm to 'fill in the gaps', resulting in a much lower effective 
resolution
Video and Data Storage 
Equipment 
2.21.1 Digital Video Recorders 
Modern endoscopic surgery towers are generally 
equipped with digital video disc (DVD) recorders 
(DVRs), which enable recording of a procedure 
in digital quality. The procedures are recorded on 
commercially available DVDs, which can later be 
viewed on normal DVD players or edited on personal 
computers. 
DVRs have evolved into devices that are feature 
rich and provide services that exceed the simple 
recording of video images that was previously 
achieved using video cassette recorders (VCRs). 
DVR systems provide a multitude of advanced 
functions, 
including video searches by event and time.
Digital Video Printers 
A variety of printers from small print 
format to 
large A5 print format are available. 
These printers 
offer high-resolution prints, quick, 20-s 
print time, 
and high-quality, curl-free prints at 400 
dpi resolution. 
Most modern printers come with a 
four-frame 
memory. The new compact design of 
printers allows 
for easy integration with other video 
equipment. 
Small, compact printers are ideal for 
the office 
setting, but large-print format printers 
are preferable 
in the operating room.
Digital Video Managers 
These are computer-based systems that 
display intuitive 
patient information screens that allow for 
quick and easy input of vital data. The data is 
stored 
on hard drives and can be viewed as images 
or 
videos, and may be stored or deleted. The 
editing 
screen enables viewing and editing 
procedures. 
Current systems allow storage of up to 50 
patient 
archives for multiple procedures. These 
systems 
are compatible with personal computers and 
hospital network software. (Courtesy of 
Richard 
Wolf, Knittlingen, Germany)
Tracking Instruments using Color 
Markers 
Place colored marker on instrument 
Convert RGB to HSV space 
Hue value of a pixel is much less susceptible to lighting changes 
Record hue value of marker to be tracked 
Search entire image for hue values within epsilon range 
Centroid of matched pixels gives position of tracker in the image 
If target is detected, localize search to a smaller neighborhood 
Tracking performed in real-time at 25 fps
 Allows shared autonomy with surgeon 
 The feedback from the tracker can be used to drive motors to 
keep the tool in the center of the image 
 PD controller used 
 ( Ex , Ey ): off set error of tracker from center of image 
Pan speed  ( x * Ex ) – ( x * dEx/dt ) 
Tilt speed  ( y * Ey ) – ( y * dEy/dt )
Stereo image
3D Trajectory Reconstruction 
 The Flock of Birds (FoB) sensor can 
transmit the position of its sensor w.r.t. 
its base 
 Accuracy within 1.8mm 
 Refresh rate up to 144Hz 
By placing an optical marker on the FoB 
sensor we can track its position in the 
image 
 By tracking the sensor using stereo 
cameras we can compute its 3D 
trajectory
Stereo Camera
3D Displays 
eMagin Z800 Head-Mounted VR Display 
- Uncomfortable 
- Single User 
RealD Crystal Eyes shutter glasses 
- Uncomfortable over longer periods 
- Need to maintain Line Of Sight with 
synchronizing emitter 
True Vision back projected 3D display 
- Low incremental cost for additional users 
- Bigger display size 
-Passive polarization, lightweight glasses
Camera in laparoscope

Weitere ähnliche Inhalte

Was ist angesagt?

Was ist angesagt? (20)

Evolution & Ergonomics in Laparoscopy
Evolution & Ergonomics in LaparoscopyEvolution & Ergonomics in Laparoscopy
Evolution & Ergonomics in Laparoscopy
 
Single Incision Laparoscopic Surgery
Single Incision Laparoscopic SurgerySingle Incision Laparoscopic Surgery
Single Incision Laparoscopic Surgery
 
Baseball diamond concept for port position in laparoscopy
Baseball diamond concept for port position in laparoscopyBaseball diamond concept for port position in laparoscopy
Baseball diamond concept for port position in laparoscopy
 
Basic of Laparoscopy
Basic of LaparoscopyBasic of Laparoscopy
Basic of Laparoscopy
 
BASICS OF LAPAROSCOPY IN GYNAECOLGY
BASICS OF LAPAROSCOPY IN GYNAECOLGYBASICS OF LAPAROSCOPY IN GYNAECOLGY
BASICS OF LAPAROSCOPY IN GYNAECOLGY
 
Basics of laparoscopy by Dr.Mohsin Khan
Basics of laparoscopy by Dr.Mohsin KhanBasics of laparoscopy by Dr.Mohsin Khan
Basics of laparoscopy by Dr.Mohsin Khan
 
Energy sources for laparoscopic surgery
Energy sources for laparoscopic surgeryEnergy sources for laparoscopic surgery
Energy sources for laparoscopic surgery
 
Evolution of laparoscopic surgery and laparoscopic instruments
Evolution of laparoscopic surgery and laparoscopic instrumentsEvolution of laparoscopic surgery and laparoscopic instruments
Evolution of laparoscopic surgery and laparoscopic instruments
 
Basics of Laparoscopy Gyn
Basics of  Laparoscopy GynBasics of  Laparoscopy Gyn
Basics of Laparoscopy Gyn
 
Introduction of Laparoscopic Surgery
Introduction of Laparoscopic SurgeryIntroduction of Laparoscopic Surgery
Introduction of Laparoscopic Surgery
 
Principle of laparoscopic surgery
Principle of laparoscopic surgeryPrinciple of laparoscopic surgery
Principle of laparoscopic surgery
 
LAPAROSCOPIC ENTRY
LAPAROSCOPIC ENTRYLAPAROSCOPIC ENTRY
LAPAROSCOPIC ENTRY
 
Laparoscopic surgery. Intro. History of Armata manus laparoscopic simulators
Laparoscopic surgery. Intro. History of Armata manus laparoscopic simulatorsLaparoscopic surgery. Intro. History of Armata manus laparoscopic simulators
Laparoscopic surgery. Intro. History of Armata manus laparoscopic simulators
 
Principles of MIS
Principles of MISPrinciples of MIS
Principles of MIS
 
Laparoscopic instruments
Laparoscopic instrumentsLaparoscopic instruments
Laparoscopic instruments
 
Complications in laparoscopic surgery
Complications in laparoscopic surgeryComplications in laparoscopic surgery
Complications in laparoscopic surgery
 
LAPAROSCOPIC HAND INSTRUMENTS, ACCESSORIES AND ERGONOMICS
LAPAROSCOPIC HAND INSTRUMENTS, ACCESSORIES AND ERGONOMICSLAPAROSCOPIC HAND INSTRUMENTS, ACCESSORIES AND ERGONOMICS
LAPAROSCOPIC HAND INSTRUMENTS, ACCESSORIES AND ERGONOMICS
 
Robotic surgery and its concepts
Robotic surgery and its conceptsRobotic surgery and its concepts
Robotic surgery and its concepts
 
Laparoscopy
LaparoscopyLaparoscopy
Laparoscopy
 
History of laparoscopy
History  of laparoscopyHistory  of laparoscopy
History of laparoscopy
 

Ähnlich wie Camera in laparoscope

Laparoscopy: Historic, Present and Emerging Trends
Laparoscopy: Historic, Present and Emerging TrendsLaparoscopy: Historic, Present and Emerging Trends
Laparoscopy: Historic, Present and Emerging Trends
George S. Ferzli
 
Endoscopic and laparoscopic surgery
Endoscopic and laparoscopic surgeryEndoscopic and laparoscopic surgery
Endoscopic and laparoscopic surgery
Anil Haripriya
 
Laparoscopy: The impact on the future
Laparoscopy: The impact on the futureLaparoscopy: The impact on the future
Laparoscopy: The impact on the future
George S. Ferzli
 
principleandapplicationsofbright-fieldmicroscopy-200512174600 (1).pptx
principleandapplicationsofbright-fieldmicroscopy-200512174600 (1).pptxprincipleandapplicationsofbright-fieldmicroscopy-200512174600 (1).pptx
principleandapplicationsofbright-fieldmicroscopy-200512174600 (1).pptx
emadkhan0110
 
Computerized Imaging Power Point
Computerized Imaging Power PointComputerized Imaging Power Point
Computerized Imaging Power Point
dare2dream143
 
Computerized Imaging Power Point
Computerized Imaging Power PointComputerized Imaging Power Point
Computerized Imaging Power Point
dare2dream143
 
Computerized Imaging Power Point
Computerized Imaging Power PointComputerized Imaging Power Point
Computerized Imaging Power Point
dare2dream143
 

Ähnlich wie Camera in laparoscope (20)

FUTURE OF LAPAROSCOPY
FUTURE OF LAPAROSCOPYFUTURE OF LAPAROSCOPY
FUTURE OF LAPAROSCOPY
 
history and techniques of Slit llamp
history and techniques of Slit llamphistory and techniques of Slit llamp
history and techniques of Slit llamp
 
Portfolio.pdf
Portfolio.pdfPortfolio.pdf
Portfolio.pdf
 
Portfolio Final.pdf
Portfolio Final.pdfPortfolio Final.pdf
Portfolio Final.pdf
 
Endoscopes - Biomedical Engineering
Endoscopes - Biomedical EngineeringEndoscopes - Biomedical Engineering
Endoscopes - Biomedical Engineering
 
FOL fibre optic laryngoscopy for ear nose and throat.pdf
FOL fibre optic laryngoscopy for ear nose and throat.pdfFOL fibre optic laryngoscopy for ear nose and throat.pdf
FOL fibre optic laryngoscopy for ear nose and throat.pdf
 
Bright field microscopy, Principle and applications
Bright field microscopy, Principle and applicationsBright field microscopy, Principle and applications
Bright field microscopy, Principle and applications
 
Laparoscopy: Historic, Present and Emerging Trends
Laparoscopy: Historic, Present and Emerging TrendsLaparoscopy: Historic, Present and Emerging Trends
Laparoscopy: Historic, Present and Emerging Trends
 
Microscopy_and_its_Application_in_Microbiology_and.pdf
Microscopy_and_its_Application_in_Microbiology_and.pdfMicroscopy_and_its_Application_in_Microbiology_and.pdf
Microscopy_and_its_Application_in_Microbiology_and.pdf
 
Endoscopic and laparoscopic surgery
Endoscopic and laparoscopic surgeryEndoscopic and laparoscopic surgery
Endoscopic and laparoscopic surgery
 
Microscopes 1[1]/ orthodontic course by indian dental academy
Microscopes 1[1]/ orthodontic course by indian dental academyMicroscopes 1[1]/ orthodontic course by indian dental academy
Microscopes 1[1]/ orthodontic course by indian dental academy
 
Microscopes 1/ orthodontic course by indian dental academy
Microscopes 1/ orthodontic course by indian dental academyMicroscopes 1/ orthodontic course by indian dental academy
Microscopes 1/ orthodontic course by indian dental academy
 
Microscopes 1 (2)/ orthodontic course by indian dental academy
Microscopes 1 (2)/ orthodontic course by indian dental academyMicroscopes 1 (2)/ orthodontic course by indian dental academy
Microscopes 1 (2)/ orthodontic course by indian dental academy
 
Laparoscopy: The impact on the future
Laparoscopy: The impact on the futureLaparoscopy: The impact on the future
Laparoscopy: The impact on the future
 
principleandapplicationsofbright-fieldmicroscopy-200512174600 (1).pptx
principleandapplicationsofbright-fieldmicroscopy-200512174600 (1).pptxprincipleandapplicationsofbright-fieldmicroscopy-200512174600 (1).pptx
principleandapplicationsofbright-fieldmicroscopy-200512174600 (1).pptx
 
Microbiology and its History.pptx
Microbiology and its History.pptxMicrobiology and its History.pptx
Microbiology and its History.pptx
 
Computerized Imaging Power Point
Computerized Imaging Power PointComputerized Imaging Power Point
Computerized Imaging Power Point
 
Computerized Imaging Power Point
Computerized Imaging Power PointComputerized Imaging Power Point
Computerized Imaging Power Point
 
Computerized Imaging Power Point
Computerized Imaging Power PointComputerized Imaging Power Point
Computerized Imaging Power Point
 
Medical x ray image sensors
Medical x ray image sensorsMedical x ray image sensors
Medical x ray image sensors
 

Kürzlich hochgeladen

Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...
Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...
Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...
ZurliaSoop
 

Kürzlich hochgeladen (20)

Basic Civil Engineering first year Notes- Chapter 4 Building.pptx
Basic Civil Engineering first year Notes- Chapter 4 Building.pptxBasic Civil Engineering first year Notes- Chapter 4 Building.pptx
Basic Civil Engineering first year Notes- Chapter 4 Building.pptx
 
Kodo Millet PPT made by Ghanshyam bairwa college of Agriculture kumher bhara...
Kodo Millet  PPT made by Ghanshyam bairwa college of Agriculture kumher bhara...Kodo Millet  PPT made by Ghanshyam bairwa college of Agriculture kumher bhara...
Kodo Millet PPT made by Ghanshyam bairwa college of Agriculture kumher bhara...
 
Python Notes for mca i year students osmania university.docx
Python Notes for mca i year students osmania university.docxPython Notes for mca i year students osmania university.docx
Python Notes for mca i year students osmania university.docx
 
General Principles of Intellectual Property: Concepts of Intellectual Proper...
General Principles of Intellectual Property: Concepts of Intellectual  Proper...General Principles of Intellectual Property: Concepts of Intellectual  Proper...
General Principles of Intellectual Property: Concepts of Intellectual Proper...
 
Jamworks pilot and AI at Jisc (20/03/2024)
Jamworks pilot and AI at Jisc (20/03/2024)Jamworks pilot and AI at Jisc (20/03/2024)
Jamworks pilot and AI at Jisc (20/03/2024)
 
Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...
Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...
Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...
 
This PowerPoint helps students to consider the concept of infinity.
This PowerPoint helps students to consider the concept of infinity.This PowerPoint helps students to consider the concept of infinity.
This PowerPoint helps students to consider the concept of infinity.
 
2024-NATIONAL-LEARNING-CAMP-AND-OTHER.pptx
2024-NATIONAL-LEARNING-CAMP-AND-OTHER.pptx2024-NATIONAL-LEARNING-CAMP-AND-OTHER.pptx
2024-NATIONAL-LEARNING-CAMP-AND-OTHER.pptx
 
FSB Advising Checklist - Orientation 2024
FSB Advising Checklist - Orientation 2024FSB Advising Checklist - Orientation 2024
FSB Advising Checklist - Orientation 2024
 
Beyond_Borders_Understanding_Anime_and_Manga_Fandom_A_Comprehensive_Audience_...
Beyond_Borders_Understanding_Anime_and_Manga_Fandom_A_Comprehensive_Audience_...Beyond_Borders_Understanding_Anime_and_Manga_Fandom_A_Comprehensive_Audience_...
Beyond_Borders_Understanding_Anime_and_Manga_Fandom_A_Comprehensive_Audience_...
 
ICT Role in 21st Century Education & its Challenges.pptx
ICT Role in 21st Century Education & its Challenges.pptxICT Role in 21st Century Education & its Challenges.pptx
ICT Role in 21st Century Education & its Challenges.pptx
 
TỔNG ÔN TẬP THI VÀO LỚP 10 MÔN TIẾNG ANH NĂM HỌC 2023 - 2024 CÓ ĐÁP ÁN (NGỮ Â...
TỔNG ÔN TẬP THI VÀO LỚP 10 MÔN TIẾNG ANH NĂM HỌC 2023 - 2024 CÓ ĐÁP ÁN (NGỮ Â...TỔNG ÔN TẬP THI VÀO LỚP 10 MÔN TIẾNG ANH NĂM HỌC 2023 - 2024 CÓ ĐÁP ÁN (NGỮ Â...
TỔNG ÔN TẬP THI VÀO LỚP 10 MÔN TIẾNG ANH NĂM HỌC 2023 - 2024 CÓ ĐÁP ÁN (NGỮ Â...
 
How to Give a Domain for a Field in Odoo 17
How to Give a Domain for a Field in Odoo 17How to Give a Domain for a Field in Odoo 17
How to Give a Domain for a Field in Odoo 17
 
Unit 3 Emotional Intelligence and Spiritual Intelligence.pdf
Unit 3 Emotional Intelligence and Spiritual Intelligence.pdfUnit 3 Emotional Intelligence and Spiritual Intelligence.pdf
Unit 3 Emotional Intelligence and Spiritual Intelligence.pdf
 
Google Gemini An AI Revolution in Education.pptx
Google Gemini An AI Revolution in Education.pptxGoogle Gemini An AI Revolution in Education.pptx
Google Gemini An AI Revolution in Education.pptx
 
How to Add New Custom Addons Path in Odoo 17
How to Add New Custom Addons Path in Odoo 17How to Add New Custom Addons Path in Odoo 17
How to Add New Custom Addons Path in Odoo 17
 
HMCS Vancouver Pre-Deployment Brief - May 2024 (Web Version).pptx
HMCS Vancouver Pre-Deployment Brief - May 2024 (Web Version).pptxHMCS Vancouver Pre-Deployment Brief - May 2024 (Web Version).pptx
HMCS Vancouver Pre-Deployment Brief - May 2024 (Web Version).pptx
 
Food safety_Challenges food safety laboratories_.pdf
Food safety_Challenges food safety laboratories_.pdfFood safety_Challenges food safety laboratories_.pdf
Food safety_Challenges food safety laboratories_.pdf
 
REMIFENTANIL: An Ultra short acting opioid.pptx
REMIFENTANIL: An Ultra short acting opioid.pptxREMIFENTANIL: An Ultra short acting opioid.pptx
REMIFENTANIL: An Ultra short acting opioid.pptx
 
Micro-Scholarship, What it is, How can it help me.pdf
Micro-Scholarship, What it is, How can it help me.pdfMicro-Scholarship, What it is, How can it help me.pdf
Micro-Scholarship, What it is, How can it help me.pdf
 

Camera in laparoscope

  • 1.
  • 2. Bozzini’s “Lichtleiter” The “Lichtleiter” was made from an aluminum tube. The tube was illuminated by a wax candle and had mirrors fitted to it in order to reflect the images. Bozzini published his invention in 1806 in the Hufeland’s Journal of Practical Medicine, Volume 24, under the title “Light Conductor, An Invention for the Viewing of Internal Parts and Diseases with Illustration.” Incidentally, Bozzini was censured for “undue curiosity” by the Medical Faculty of Vienna for this invention. (Courtesy of Olympus Austria,
  • 3. Antoine Jean Desormeaux Antoine Jean Desormeaux (1815–1894), a French Surgeon, was the first to introduce the Bozzini’s “Lichtleiter” into a patient. In 1853, he further developed the Lichtleiter and termed his device the “Endoscope.” It was the first time this term was used in history. Desormeaux presented the endoscope in 1865 to the Academy in Paris. He even used his endoscope to examine the stomach; but due to an insufficient light source he was not quite successful. (Copyright Verger-Kuhnke AB. The life of Philipp Bozzini (1773-1809), an idealist of endoscopy. Actas Urol Esp. 2007;31:437-444)
  • 4. Desormeaux’s “Endoscope” Desormeaux’s endoscope used as a light source a kerosene lamp Berning alcohol and turpentine, with a chimney to enhance the flame and a lens to condense the beam to a narrower area to achieve a brighter spot. He used this instrument to examine the urethra and bladder. As might have been expected, burns were the major complication of these procedures. Interestingly, he thought of using electricity but felt it unsafe. (Courtesy of Olympus Austria, Vienna, Austria)
  • 5. Johannes Freiherr surgeon of Polish-Lithuanian descent born in Bukowina, Romania, constructed the first rigid endoscope in 1880 and was the first to use Edison’s light bulb for his gastroscope in practice. He modified the instrument so that it could be angled by 30Åã near to its lower third to achieve better visualization. He added a separate channel for air insufflation. In one of the first interventional endoscopic procedures, he pushed a large swallowed bone from the esophagus into the stomach, thus avoiding surgery. (Copyright: surgeon in the evolution of flexible endoscopy. Surg Endosc 2007: 21; 838-853 Springer Verlag)
  • 6. Georg Kelling (1866–1945), a German physician from Dresden, was introduced to endoscopy and gastrointestinal surgery when he worked with Professor Mikulicz- Radecki at the Royal Surgical Clinic in Breslau, Germany. In with the help of Nitze’s cystoscope, and coined this laparoscopic examination “celioscopy.” He used air filtered through sterile cotton to create pneumoperitoneum in dogs. For insufflation he used a trocar Developed by Alfred Fiedler, an internist from Dresden. (Copyright: Hatzinger M: Georg Kelling (1866–1945) Der Erfinder der modernen Laparoskopie. Urologe A 2006; 45 (7):868-71 Springer Verlag)
  • 7. Harold Horace Hopkins Hopkins (1918–1994) obtained a degree in physics and mathematics at Leicester University in 1939. After the war, in 1947, Hopkins became a research fellow at Imperial College, London, UK. Hopkins invented the rigid rod-lens system for scopes, which allows double light transmission, requires short and thin spacer tubes, and gives a larger and clearer aperture. He filed a patent for the rod-lens system in 1959. However, the English and American companies to whom he offered the system displayed little interest. The situation changed however in 1965 when Professor George Berci, who recognized the potential of this invention, introduced Hopkins to Karl Storz to manufacture the scopes. (Courtesy of William P. Didusch Center for Urologic History, American Urological Association, MD, USA)
  • 8. Kurt Karl Stephan Semm Kurt Karl Stephan Semm (1927–2003) was born in Munich, Germany, where he also studied medicine at the Ludwigs- Maximillian University. In 1958, he wrote his medical thesis under the guidance of Nobelmlaureate Adolf Butenandt. Semm began his career in gynecology under Professor Fikentscher in Munich. In 1970s, as the Head of Gynecology in Kiel, introduced an; 1- Automatic insufflation device capable of monitoring intra-abdominal pressures, 2- Endoscopic loop sutures, 3-Extra- and intracorporeal suturing techniques. 4-Created the pelvi- trainer. He performed the first laparoscopic appendectomy in 1982. (Courtesy of Monika Bals-Pratsch MD, Zentrum für Gyn.kologie, Universit.t Regensburg, Germany)
  • 9. Anatomy of a Rigid Scope
  • 10.  Central to the instrumentation is the scope. Its backbone is the rod lens system designed by Hopkins.  The shaft of scopes houses both light fibers  and viewing optics.  The viewing optic consist of three distinct parts: o The objective lens, o Rod lenses, o ocular lens.
  • 11. Field of View The field of view (also field of vision) is the angular extent of the observable area that is seen at any given moment. The field of view in scopes for endoscopic surgery can vary from 600 to 820 depending up on the type of instrument. Wider angles of view provide a greater depth of field in the image with better utilization of illumination. A smaller field of view allows the scope to be farther from the tissue, for the same to be observed.
  • 12. Angle of View The angle of view in scopes can vary with respect to the central axis view are designated as 00 and provide a straight view of the structure in question. Scopes are also available with a 50, 250, 300, 450, and even 700 angle of view, allowing utilization of the scopes much as a periscope. The off-axis scopes enable one to observe down into the gutters and up the anterior abdominal wall as well as sideways. Off-axis scopes are difficult to work with; however, they provide an excellent means of obtaining close inspection of tissues at difficult angles and positions.
  • 13. Scope Size and Screen Image The decrease in the size of scopes was an important factor in the advancement of minimally invasive surgery in the pediatric age group. Although scopes are available in sizes from 1.9 mm to 12 mm in diameter, the majority of the procedures are performed using 5- or 10-mm scopes. When compared to the reduced view obtained in the previous generation of scopes (left), modern5-mm, full-screen scopes provide a bright, distortion- free, full-screen image (right). In addition, the image size in modern 5-mm scope is equivalent to that obtained by the previous-generation 10-mm scope. (Courtesy of Richard Wolf, Knittlingen, Germany)
  • 14. Charge Coupled Device (CCD) Video Cameras Scope cameras are available in either single-chip three-chip versions (one chip offers 300,000 pixels/cm2). In single-chip CCD cameras, all the three primary colors (red, blue and green) are sensed by a single chip. In three-chip CCD cameras, there are three chips for separate capture and processing of the primary colors. Single-chip CCD cameras produce images of 450 lines/inch resolution and are ideal for outpatient surgery. On the other hand, three-chip CCD cameras have high fidelity with unprecedented color reproduction to produce images of 750 lines/ inch resolution that can be viewed optimally on flat-panel screens and are best suited for endoscopic surgery. (Courtesy of RichardWolf, Knittlingen , Germany) Light source: Light-Source Generators and Transmission Pathways There are two commonly utilized light sources: halogen and xenon. A schematic overview of light transmission is outlined12
  • 15. The Concept of White Balancing White balancing should be performed before inserting the camera inside the abdominal cavity. This is necessary before commencing surgery to diminish the added impurities of color that may be introduced due to a variety of reasons such as: (1) voltage difference, (2) staining of the tip by cleaners, (3) scratches and wear of the eyepiece. White balancing is achieved by keeping a white object in front of the scope and activating the appropriate button on the video system or camera. The camera senses the white object as its reference to adjust all of the primary colors (red, blueand green). (Courtesy of Richard Wolf, Knittlingen, Germany)
  • 16.
  • 17. A three-CCD camera is a camera whose imaging system uses three separate charge-coupled devices (CCDs), each one taking a separate measurement of the primary colors, red, green, or blue light. Light coming into the lens is split by a trichroic prism assembly, which directs the appropriate wavelength ranges of light to their respective CCDs. The system is employed by still cameras, telecine systems, professional video cameras and some prosumer video cameras.
  • 18. Rods and Cones The retina contains two types of photoreceptors, Rods cones. The rods are more numerous, some 120 million, and are more sensitive than the cones they are not sensitive to color. The 6 to 7 million cones provide the eye's color sensitivity and they are much more concentrated in the central yellow spot known as the macula. In the center of that region is the " fovea centralis ", a 0.3 mm diameter rod-free area with very thin, densely packed cones. The experimental evidence suggests that among the cones there are three different types of color reception. Response curves for the three types of cones have been determined. Since the perception of color depends on the firing of these three types of nerve cells, it follows that visible color can be mapped in terms of three numbers called tristimulus values. Color perception has been successfully modeled in terms of tristimulus values and mapped on the CIE chromaticity diagram.
  • 19. Rods Do Not See Red! The light response of the rods peaks sharply in the blue; they respond very little to red light. This leads to some interesting phenomena: Red rose at twilight: In bright light, the color-sensitive cones are predominant and we see a brilliant red rose with somewhat more subdued green leaves. But at twilight, the less-sensitive cones begin to shut down for the night, and most of the vision comes from the rods. The rods pick up the green from the leaves much more strongly than the red from the petals, so the green leaves become brighter than the red petals! The ship captain has red instrument lights. Since the rods do not respond to red, the captain can gain full dark-adapted vision with the rods with which to watch for icebergs and other obstacles outside. It would be undesirable to examine anything with white light even for a moment, because the attainment of optimum night-vision may take up to a half-hour. Red lights do not spoil it. These phenomena arise from the nature of the rod-dominated dark-adapted vision, called scotopic vision.
  • 20. Cone Details Current understanding is that the 6 to 7 million cones can be divided into "red" cones (64%), "green" cones (32%), and "blue" cones (2%) based on measured response curves. They provide the eye's color sensitivity. The green and red cones are concentrated in the fovea centralis . The "blue" cones have the highest sensitivity and are mostly found outside the fovea, leading to some distinctions in the eye's blue perception. The cones are less sensitive to light than the rods, as shown a typical day-night comparison. The daylight vision (cone vision) adapts much more rapidly to changing light levels, adjusting to a change like coming indoors out of sunlight in a few seconds. Like all neurons, the cones fire to produce an electrical impulse on the nerve fiber and then must reset to fire again. The light adaption is thought to occur by adjusting this reset time. The cones are responsible for all high resolution vision. The eye moves continually to keep the light from the object of interest falling on the fovea centralis where the bulk of the cones reside.
  • 21.
  • 22. The combination of the three sensors can be done in the following ways: Composite sampling, where the three sensors are perfectly aligned to avoid any color artifact when recombining the information from the three color planes Pixel shifting, where the three sensors are shifted by a fraction of a pixel. After recombining the information from the three sensors, higher spatial resolution can be achieved. Pixel shifting can be horizontal only to provide higher horizontal resolution in standard resolution camera, or horizontal and vertical to provide high resolution image using standard resolution imager for example. The alignment of the three sensors can be achieved by micro mechanical movements of the sensors relative to each other. Arbitrary alignment, where the random alignment errors due to the optics are comparable to or larger than the pixel size.
  • 23. Compared to cameras with only one CCD, three-CCD cameras generally provide superior image quality through enhanced resolution and lower noise. By taking separate readings of red, green, and blue values for each pixel, three-CCD cameras achieve much better precision than single-CCD cameras. By contrast, almost all single-CCD cameras use a Bayer filter, which allows them to detect only one-third of the color information for each pixel. The other two-thirds must be interpolated with a demosaicing algorithm to 'fill in the gaps', resulting in a much lower effective resolution
  • 24. Video and Data Storage Equipment 2.21.1 Digital Video Recorders Modern endoscopic surgery towers are generally equipped with digital video disc (DVD) recorders (DVRs), which enable recording of a procedure in digital quality. The procedures are recorded on commercially available DVDs, which can later be viewed on normal DVD players or edited on personal computers. DVRs have evolved into devices that are feature rich and provide services that exceed the simple recording of video images that was previously achieved using video cassette recorders (VCRs). DVR systems provide a multitude of advanced functions, including video searches by event and time.
  • 25. Digital Video Printers A variety of printers from small print format to large A5 print format are available. These printers offer high-resolution prints, quick, 20-s print time, and high-quality, curl-free prints at 400 dpi resolution. Most modern printers come with a four-frame memory. The new compact design of printers allows for easy integration with other video equipment. Small, compact printers are ideal for the office setting, but large-print format printers are preferable in the operating room.
  • 26. Digital Video Managers These are computer-based systems that display intuitive patient information screens that allow for quick and easy input of vital data. The data is stored on hard drives and can be viewed as images or videos, and may be stored or deleted. The editing screen enables viewing and editing procedures. Current systems allow storage of up to 50 patient archives for multiple procedures. These systems are compatible with personal computers and hospital network software. (Courtesy of Richard Wolf, Knittlingen, Germany)
  • 27. Tracking Instruments using Color Markers Place colored marker on instrument Convert RGB to HSV space Hue value of a pixel is much less susceptible to lighting changes Record hue value of marker to be tracked Search entire image for hue values within epsilon range Centroid of matched pixels gives position of tracker in the image If target is detected, localize search to a smaller neighborhood Tracking performed in real-time at 25 fps
  • 28.  Allows shared autonomy with surgeon  The feedback from the tracker can be used to drive motors to keep the tool in the center of the image  PD controller used  ( Ex , Ey ): off set error of tracker from center of image Pan speed  ( x * Ex ) – ( x * dEx/dt ) Tilt speed  ( y * Ey ) – ( y * dEy/dt )
  • 30. 3D Trajectory Reconstruction  The Flock of Birds (FoB) sensor can transmit the position of its sensor w.r.t. its base  Accuracy within 1.8mm  Refresh rate up to 144Hz By placing an optical marker on the FoB sensor we can track its position in the image  By tracking the sensor using stereo cameras we can compute its 3D trajectory
  • 32. 3D Displays eMagin Z800 Head-Mounted VR Display - Uncomfortable - Single User RealD Crystal Eyes shutter glasses - Uncomfortable over longer periods - Need to maintain Line Of Sight with synchronizing emitter True Vision back projected 3D display - Low incremental cost for additional users - Bigger display size -Passive polarization, lightweight glasses