Anzeige
Anzeige

Más contenido relacionado

Presentaciones para ti(20)

Anzeige
Anzeige

Distributor presentation mx

  1. flow measurement
  2. Presentation Overview 1.Flow meter technology 2.Positive Displacement - Principle of operation. 3.Ideal applications 4.What's new 5.Introducing the new generation MX series Flowmeters.
  3. Flowmeter Technologies There are 4 general groupings by which a flow meter can be categorised, according to the technology adopted.  Velocity  Inferential  Mass  Volumetric Flow Measurement Technology
  4. Volumetric Flowmeter ‘Directly measure the total volume of the fluid passing through the pipe’       Oval Gear Rotary Nutating Disc Bi-Rotor Spur Gear Oscillating Piston Flow Measurement Technology
  5. Typical Applications Volumetric • • • • • Batching Dispensing Dosing Fuel Consumption Applications requiring accurate totals Flow Measurement Technology
  6. Positive Displacement Flowmeter
  7. Principle of Operation A precision engineered measuring chamber houses a pair of oval rotors which rotate during flow conditions Meter Construction
  8. Principle of Operation As the Rotors turn they sweep a measured volume of liquid through the measuring chamber Measured Volume Measuring Chamber
  9. Principle of Operation • Each of the Rotors are fitted with magnets on the top face. • As the Rotor turns the magnet activates a switch which is fixed to a Printed Circuit Board (PCB) • This in turn generates a Pulse Output
  10. Principle of Operation Our Sensor Boards (PCB) incorporate two types of switches.  Reed Switch Mechanical Switch  Hall Effect Switch Solid State Electronics – Printed Circuit Board
  11. Calculating Flow Rate • The K- Factor is … ‘The number of Sensor Pulses per Unit of Measure’ (Litre or US gallon) • Each meter is assigned an individual K-Factor calculated during our calibration checks Example ….  A meter has an independent K-Factor 36 (= 36 pulses per litre)  Each pulse generated by the meter is the equivalent to 1 Ltr ÷ 36 = 27.8 ml  An Electronic device (Signal Conditioner) is used to convert these pulse outputs to Flow Rate and Total Flow K-Factor
  12. The Benefits associated with a PD Meter
  13. Technical Specifications  Accuracy • +/- 0.5% (500ml in every 100 litres)  Repeatability • 0.03% (30ml in every 100 litres) Flow Measurement Technology
  14. Installation and Commissioning  Reliable  Robust  Easily maintained on site  No pipe conditioning required  Suitable for variations in medium (e.g. viscosity, concentrations, etc. ) Flow Measurement Technology
  15. Suitable Applications
  16. Ideal Applications Dispensing  Refuelling  Vehicle Servicing  Drum Filling  Chemical Packaging Positive Displacement Flow Meters
  17. Servicing and Transfer
  18. Diesel Service Truck
  19. Diesel Service Truck
  20. Diesel Service Truck
  21. Ideal Applications Batching  Chemical Dilution and Packaging  Food / Baking  Animal Feed Flow Measurement Technology
  22. Automatic Batching
  23. Automatic Filling System
  24. Multiple Drum Filling
  25. Portable Batching System
  26. New application – AdBlue metering
  27. Fuel Consumption System Recirculation Fuel System - Meter Installation - Schematic Receiving Instrument Master Fuel Filter Fi lte r Fuel Tank NonReturn Valve Fuel Consumption calculated as Meter P1 Meter P2 Meter P1 Engine Meter P2
  28. Ideal Applications High Viscosity      Fuels and Lubricants Paints and Coatings Adhesives Printing Ink Cleaning Chemicals Positive Displacement Flow Meters
  29. Agricultural Dispensing
  30. What’s New?
  31. The new MX Flowmeter series  Pulser range only  Manufactured from solid Billet (St.St and Aluminium)  Increased Temp (150oC)  Pressure Ratings (2000psi)  Anodised Aluminium body  Choice of 9 interchangeable Pulse Output or Display Modules.
  32. M-Lock™ mounting system We have developed a new ¼” turn (Bayonet fitting) mounting system for our Pulse Output and Display modules.
  33. Approved for Hazardous Areas  Intrinsically Safe (Ex ia)  Flameproof (Exd)  Approved ATEX,  Approved IECEx pending *Note: Ex option only available with the Industrial Flowmeter Series
  34. Online Resources Macnaught has developed a comprehensive set of web based resources in order to support customers throughout the entire process of selecting, applying and maintaining the MX Flow meter range. http://www.macnaught.com.au/mx_resources/index.html
  35. Interactive Web Tools  Automated Flowmeter Selection Tool  Specifications Tool  Conversion Tool (coming soon)
  36. Online Information General web based resources Quick Reference Guides General Specifications 3D Drawings Instruction Manuals Service Videos Brochures
  37. Marketing Resources MX Demo Kit We have developed an MX Demonstration Kit to compliment the launch of the MX series. table top exhibitions in-house display staff training direct sales tool.
  38. Overview of the new generation MX Series
  39. Flowmeter Range overview  The range consists of over 1,000 flowmeter models.  Process Connection sizes range from ¼” to 4” (6mm – 100mm)  Flow Rates range from 0.0083 – 1200 l/min  Stainless Steel and Alum.
  40. Range Segmentation Application Based Focused on Ideal applications 1. Fuel and Oil 2. Solvent 3. Industrial All Inclusive PART number 1. Includes Flange Styles 2. Includes displays
  41. MX part numbering convention
  42. MX25F-1SA Breakdown of the part numbering system Part Number
  43. MX25F-1SA Breakdown of the part numbering system MX … Flowmeter Series Part Number
  44. MX25F-1SA Breakdown of the part numbering system MX … Flowmeter Series 25 … Size and Flow Range Part Number
  45. MX25F-1SA F Breakdown of the part numbering system MX … Flowmeter Series 25 … Size and Flow Range F … Industry Type or Family Part Number
  46. MX25F-1SA Breakdown of the part numbering system MX … Flowmeter Series 25 … Size and Flow Range F … Industry Type or Family 1 … Port style (process connection) Part Number
  47. MX25F-1SA Breakdown of the part numbering system MX … Flowmeter Series 25 … Size and Flow Range F … Industry Type or Family 1 … Port style (process connection) S … Rotor Type Part Number
  48. MX25F-1SA Breakdown of the part numbering system MX … Flowmeter Series 25 … Size and Flow Range F … Industry Type or Family 1 … Port style (process connection) S … Rotor Type A … Display or Pulser Output Type Part Number
  49. MX25F-1SA Size and Flow Range Model No. (mm) Size Flow Range MX06 ¼” 0.5 – 100 l/hr MX09 ¼” 15 – 500 l/hr MX12 ½” 2 – 30 l/min MX19 ¾” 3 – 80 l/min MX25 1” 6 – 120 l/min MX40 1 ½” 10 – 250 l/min MX50 2” 15 – 500 l/min MX75 3” 20 – 750 l/min MX100 4” 120 – 1200 l/min
  50. MX25F-1SA Industry Type or Family Fuel and Oil (F) Solvents (S) Industrial (P) • Al meter body • PPS rotors • Viton Seals • • • • • • Al meter body SS rotors Teflon Seals Fuel & Oil Flowmeters SS meter body PPS or SS rotors Teflon Seals
  51. MX25F-1SA Port Style (process connection) 1. 2. 3. 4. 5. BSP (Rp) NPT ANSI 150lb JIS 10K DIN PN16
  52. MX25F-1SA Rotor Type Fuel and Oil series S = PPS Rotors Solvent series S = Models MX06 - MX025 Models MX40 – MX100 Stainless Steel Rotors Aluminium Rotors Industrial series S = PPS V = High Viscosity Stainless Steel Rotors T = High Temp Stainless Steel
  53. MX25F-1SA Display or Pulser Output Modules A B C D E F G H T Standard Pulse Intrinsically Safe (Ex ia) Flameproof (Ex d) PR (12mm LCD) PRA (12mm LCD with outputs) ER (17mm LCD) ERA (17mm LCD with outputs) ERB (17mm LCD Batch controller) High Temp (max 150oC)
  54. Pulser Output and Display Modules
  55. Type A Compact Compact • • • • • Polypropylene Housing IP 67 Pulser Output 1x Reed switch 1x Hall Effect (NPN)
  56. Type B Approved Ex ia Intrinsically Safe • • • • • • • • Stainless Steel Pulser Output NPN Open Collector Approved Ex ia ATEX FM CSA IECEx pending *Note: Ex option only available with the Industrial Flowmeter Series
  57. Type C Approved Exd Flameproof • • • • • • Stainless Steel Pulser Output NPN Open Collector Approved Exd ATEX IECEx pending *Note: Ex option only available with the Industrial Flowmeter Series
  58. Type D PR Digital Display Display • • • • • • • Meter Mount or Wall Mount Polypropylene Housing IP67 7 Digit – 12mm upper 7 Digit – 8mm lower Total Resettable Flow Rate Accumulated Total (non-resettable)
  59. Type E PRA Digital Display Display • • • • • • • Meter Mount or Wall Mount Polypropylene Housing IP67 7 Digit – 12mm upper 7 Digit – 8mm lower Total Resettable Flow Rate Accumulated Total (non-resettable) Outputs • • • 4-20mA (passive) Scaled Pulse Output Hi/Lo Flow Alarm
  60. Type F ER Digital Display Display • • • • • • • Meter Mount or Remote Mount Aluminium housing IP 67 7 Digit – 17mm upper 7 Digit – 8mm lower Total Resettable Flow Rate Accumulated Total (non-resettable)
  61. Type G ERA Digital Display Display • • • • • • • Meter Mount or Remote Mount Aluminium housing IP 67 7 Digit – 17mm upper 7 Digit – 8mm lower Total Resettable Flow Rate Accumulated Total (non-resettable) Output • 4-20mA (passive) • Scaled Pulse
  62. Type H ERB Batch Controller Display • • • • • • • Meter Mount or Remote Mount Aluminium housing IP 67 7 Digit – 17mm upper 7 Digit – 8mm lower Total Resettable Flow Rate Accumulated Total (non-resettable) Output • 4-20mA (passive) • Scaled Pulse
  63. Type T High Temperature Intrinsically Safe • • • • Stainless Steel Pulser Output NPN Open Collector Max temp 150oC
  64. ERS Digital Register Summation / Differential Display • • • • • • • Remote Mount only Aluminium housing IP 67 7 Digit – 17mm upper 7 Digit – 8mm lower 2 Flowmeter inputs Calculates differential Sums Output • Transistor
  65. Accessories Flanged Process Connections • Flanges are now screwed into the Meter body • Available in ANSI, DIN, JIS Wall Mount Adaptors • Aluminium wall mount adaptors available for models MX06-25 Strainers / Air Eliminators • A variety of SS Y-Strainers, and Air Eliminator/Strainer combinations are available. Turck Cables •2mtr cables to suit Ex ia and High Temp Pulser switches
  66. End Presentation