SlideShare ist ein Scribd-Unternehmen logo
1 von 23
Downloaden Sie, um offline zu lesen
LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 1




 L aGuna B ay S paS
                                 Get Away...
                                 Every Day.




                        Owner’s Guide Book
LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 2




                            Important information about your
                                 LaGuna Bay Spa

   Spa Model

   Spa Serial number

   Date of purchase

   Dealer name

   Ozone Generator                          yes                            no

   prozone System                           yes                            no

   Chemicals used




   Filter Information                       Length                         Width


   Keeping this information on hand will help if you ever need technical assistance. It is also helpful
   if you can provide pictures for the technician. pictures allow the technician to see the area of
   concern as if looking at it along side you.

   Taking pictures before calling technical support will help expedite resolution - you will be able to
   email the pictures directly to the technician while you are on the call.

              For technical assistance, please call 877.722.4097
    Technical Support is available Monday through Friday from 8:30 am
                     to 5:00 pm Eastern Standard Time




                                                     2
LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 3




                                   Index
           Important Safety Information Begins on Page 4
                              playing it safe while you play




                  Location Information Begins on Page10
                   The “Wheres” and “Hows” of choosing and preparing
                            the best place for your new spa




                 Electrical Information begins on Page 12
                         The magnetic relationship with your spa
                              shouldn’t come with a shock




           Information about hardware & filling your spa
                         begins on page 16
            putting the right water in the right way makes a big difference.




           Water Chemistry Information begins on page 20
                   Chrystal clear instructions for chrystal clear water




                                              3
LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 4




                       Important Safety Information

               Read and CaRefully follow InstRuCtIons !
                            Basic safety precautions must be followed including:

                          Avoiding the Risk to ChildRen




         dAngeR:
         Risk of Children drowning. extreme caution must be used to prevent unauthorized access by
         children. to avoid accidents, ensure that children cannot use a spa unless they are supervised at all
         times.
         WARning:
         to reduce risk of injury, do not allow children to use this product unless they are closely
         supervised at all times.
         to reduce the risk of injury, lower water temperature when spa is used by children. lower water
         temperatures are recommended since children are especially sensitive to hot water.
         do:
         Make sure you always lock child resistant locks after using the spa for your children’s safety.
         every laguna Bay spa is equipped with a locking cover that meets the atsM f1346-91 standard for
         safety Covers. there is no representation that the use of the cover, locking clips or actual locks will
         not prevent access to the spa.
         test the water temperature with your hands before allowing children to enter the spa to be sure
         that it’s comfortable. Children are especially sensitive to hot water.
         Remind children that wet surfaces are slippery. Make sure that children are careful when
         entering and exiting the spa.
         Check with local authorities regarding fencing requirements for spas in you area.
         don’t:
         Allow children or pets on the spa cover. Covers are strong enough to withstand the weight of
         tone foot of snow. they are not designed to support the weight of people or pets. sitting on the cover
         may cause the foam inners to break.
         Allow children to have unsupervised access to the spa.

                    Avoiding the Risk oF eleCtRoCUtion




         lAgUnA BAy spAs ReCoMMends thAt eleCtRiCAl
                  CoMponents Be instAlled
               only By A liCensed eleCtRiCiAn.
         to ensure the spa functions properly and to ensure your warranty is not compromised by improper
         installation, you must have a licensed electrician install all electrical components.

                                                         4
LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 5




                       Important Safety Information

        Risk oF eleCtRoCUtion
        Connect only to a grounded source.
        if your spa model is equipped with a cord, do not bury the cord. a buried cord may result in
        death or serious injury due to electrocution if direct burial-type cable is not used, or if improper
        digging occurs.
        install at least five feet (1.5m ) from all metal surfaces. If this is not possible, a ground
        terminal (pressure wire connector) is provided on the control box inside the unit to permit connection
        with solid copper bonding conductor between this point and any metal equipment, metal water pipe,
        metal enclosures of electrical equipment, or conduit within five feet (1.5m) and within sight of the spa.
        do not permit any electrical appliances, such as lights, telephones, radios or televisions within
        five feet (1.5m) of the spa unless they were built in by the manufacturer. failure to maintain a safe
        distance may result in death or serious injury from electrocution if the appliance should fall into the
        spa.
        WARning
        to reduce the risk of electric shock, if your spa is equipped with a cord, replace damaged cord
        immediately. failure to do so may result in death or serious permanent injury by electrocution.
        your spa requires a ground Fault Circuit interrupter for user and equipment protection in
        compliance with section 680-42 of the national electrical Code, ansI/nfPa 70-1993. to ensure
        proper operation of the important safety device, test according to the following instructions with regard
        to your electrical configuration:
        Cord-Connected 115 volt, 20 amp: the GfCI is located at the end of the power cord. Before
        each use, with the unit operating, push the “test” button. the unit should stop operating and the
        GfCI power indicator will go out. wait 30 seconds and then reset the GfCI by pushing the “Reset”
        button. the GfCI power indicator will turn on, restoring the power to the spa. If the interrupter does
        not perform in this manner, there may be an electrical malfunction and with it, the possibility of an
        electric shock. disconnect the power until the problem has been corrected. Please note this action will
        automatically reset the filter cycle of the spa.
        220 volt, permanently installed or converted models: a ground terminal is provided on the
        terminal block located inside the control box. to reduce the risk of electric shock, connect the
        terminal to the grounding terminal of your electrical service or supply panel with a continuous green,
        insulated copper wire. a bonding terminal (pressure wire connector) is provided on the outside of the
        control box for bonding to local ground points. to reduce the risk of electric shock, this connector
        should be bonded with solid copper wire to any metal ladders, water pipes, or other metal within five
        feet (1.5m) of the spa to comply with local requirements. the means of disconnection must be readily
        accessible, but must be installed at least five feet (1.5m) from the spa.
        do:
        Make sure your spa is properly connected - Use A liCensed eleCtRiCiAn
        disconnect the spa from the power supply before draining and servicing components.
        test the ground Fault interrupter(s) before each use.
        don’t
        Use the spa with the equipment compartment door removed.
        Replace components except with identical components supplied by the manufacturer.
        operate audio or video equipment while inside the spa unless it is with the remote approved or
        provided by the manufacturer. do not connect auxiliary components (i.e. headphones) to the system.
        place electrical appliances within five feet (1.5m) of the spa.
        Use an extension cord to connect the spa to its power source. the cord may not be properly
        grounded and the connection is a shock hazard. an extension cord may cause a voltage drop, which
        will cause overheating of the pump(s), cause motor damage and will void the manufacturer’s warranty.
        Attempt to open the electrical control box. there are no serviceable parts inside the box.



                                                         5
LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 6




                        Important Safety Information

                                            AvoidABle Risks




          dAngeR: Risk oF injURy
          the suction fittings in this spa are sized to match the specific water flow created by the pump.
          If it is necessary to replace the suction fittings or the pump, be sure the flow rates are compatible.
          Because of the risk of injury,
          never operate the spa if the suction fittings are broken or missing. Please contact your dealer or
          nearest service center for service or repair.
          never operate the spa if the floating weir(s), filter(s), filter lid(s) or skimmer(s), or skimmer
          assembly(s) are missing. Please contact your dealer or nearest service center for service or repair.
          never replace suction fitting with one rated less than the flow rate marked on the original
          suction fitting.
          do not remove floating weir(s), basket(s) or filter(s) while spa is running.
          keep all loose articles of clothing, hair or hanging jewelry away from suction fittings, rotating
          jets or other moving components.
          exercise care when entering and exiting the spa. wet surfaces can be slippery.
          inCReAsed side eFFeCts oF MediCAtion
          the use of drugs, alcohol, or medication before or during spa use may lead to
          unconsciousness with the possibility of drowning.
          persons using medication should consult a physician before using a spa; some medication
          may cause a user to become drowsy, while other medication may affect the heart rate, blood pressure
          or circulation.
          persons taking medications which induce drowsiness, such as tranquilizers, antihistamines
          or anticoagulants should not use a spa.
          heAlth pRoBleMs AFFeCted By spA Use
          pregnant or possibly pregnant women should consult a physician before using a spa.
          persons suffering from obesity or with a medical history of heart disease, low or high blood
          pressure, circulatory problems, infectious diseases, immune deficiencies, infectious diseases, infections
          skin irritations, or diabetes should consult a physician before using a spa.
          Always shower before and after using a spa. to reduce the possibility of contracting a
          waterborne illness, always maintain water chemistry within the parameters in this manual. If other
          bathers are affected by such a condition, discontinue use and consult a physician.
          UnCleAn WAteR
          keep the water clean and sanitized with correct chemical care to help maintain safe water and
          prevent possible damage to spa components. the recommended levels for your laguna Bay spa
          are:

          free available Chlorine (faC): 3.0 to 5.0 ppm             total alkalinity        125 to 150 ppm
          water pH: 7.4 to 7.6                                      Calcium Hardness        150 to 200 ppm

          Refer to water Quality and Maintenance section for further information and complete instructions
          about water and spa care.




                                                          6
LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 7




                        Important Safety Information

          iMpoRtAnt: turn jet pump on for at least ten minutes after adding Any spa water
          chemicals into the filter compartment.
          Clean the filter cartridge monthly to remove debris and mineral buildup which may affect the
          performance of hydrotherapy jets, limit the water flow, or trip the high limit thermostat which will
          turn off the entire spa to prevent further damage to the spa.




                    Avoiding the Risks oF hypeRtheRMiA
          prolonged immersion in hot water can result in HyPeRtHeRMIa, a dangerous condition
          which occurs when the internal temperature of the body reaches a level above normal (98.6ºf).
          the symptoms of hyperthermia include unawareness of impending hazard, failure to perceive
          heat, failure to recognize the need to exit the spa, physical inability to exit the spa, fetal damage in
          pregnant women, and unconsciousness resulting in a danger of drowning.
          the use of alcohol, drugs or medication can greatly increase the risk of fatal hyperthermia
          in spas.
          to reduce the risk of injury:
          the Consumer products safety Commission has stated that the water in the spa should
          never exceed 104ºf (40ºC). water temperatures between 100ºf (38ºC) and 104ºf (40ºC) are
          considered safe for a healthy adult. lower water temperatures are recommended for extended use
          (exceeding 10 minutes) and for young children. extended use can cause hyperthermia.
          pregnant or possibly pregnant women should limit spa water temperatures to 100ºf (38ºC).
          failure to do so may result in permanent injury to your baby. you should consult with a physician
          prior to using a spa.
          do not use a spa immediately after strenuous exercise.
          do:
          Measure the water temperature with an accurate thermometer before entering the spa to
          verify the digital thermometer since the tolerance of water temperature regulating devises may vary
          as much as +/- 5ºf (2ºC).
          test the water with your hand to be sure it’s comfortable before entering the spa.
          don’t:
          Use alcohol or drugs before or during spa use. stay well hydrated and drink plenty of water.
          stay in the spa for extended periods of time. If you are going to be in the spa for more than
          10 minutes, you should reduce the temperature of the spa to 100ºf (40ºC) or lower.

                             iMpoRtAnt spA instRUCtions
          do:
          Use and lock the vinyl cover when spa is not in use whether it is empty or full. Because heat
          retentive materials are used to insulate the spa for efficient operation, an uncovered spa surface with
          direct exposure to sunlight and high temperatures for long periods of time is subject to permanent
          damage. damage caused by exposing the spa to this abuse is not covered by the warranty.




                                                           7
LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 8




                       Important Safety Instructions

       Follow spa care and maintenance stated in this owner’s Guide.
       Use only approved and recommended accessories, chemicals and cleaners.
       don’t:
       leave the spa exposed to the sun without water or the vinyl cover in place. exposure to direct
       sunlight can cause solar distress of the shell material.
       Roll or drag the spa on its side. this will damage the siding.
       lift or drag the cover by using the cover lock tie downs. always lift or carry the cover by using the
       handles.
       Attempt to open the spa control box. there are no user serviceable parts inside the spa control box
       (spa pack box) . opening of the control box by the spa owner, unless instructed by the manufacturer’s
       factory trained technical support technician will void the warranty. If you have an operational problem,
       carefully go through the steps outlined in the troubleshooting section. If you are not able to resolve the
       problem, please call technical support at 877-722-4097. Many problems can easily be diagnosed over
       the telephone by the service technician.




                                                FCC notiCe
       If your spa is equipped with audio or video equipment, it has been tested and found to comply with the
       limits for a class B digital device, pursuant to Part 15 of the fCC Rules. these limits are designed to
       provide reasonable protection against harmful interference in a residential installation. this equipment
       generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with
       the instructions, use harmful interference to radio communications. However, there is no guarantee that
       the interference will no occur in a particular installation. If this equipment does cause harmful
       interference to radio or television reception, which can be determined by turning the equipment on and
       off, the user is encouraged to try to correct the interference by one or more of the following measures:

       1.         Rearrange or relocate the receiving antenna;

       2.         Increase the separation between equipment and receiver;

       3.         Connect the equipment into an outlet on a circuit different from the circuit connected.

       4.         Consult the dealer or an experienced radio/tV technician for help.

       any changes or modifications not expressed or approved by party responsible for fCC compliance could
       void the user’s authority to operate this equipment.




                                                         8
LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 9




                   Important Safety Instructions


                    important CsA safety instructions




                                        (Canada only)

       when using this electrical equipment, basic safety precautions should always be
       followed, including the following:

       1.       Read and follow all InstRuCtIons.

       2.       a green colored terminal or a terminal marked G, Gr, Ground, Ground-
                ing or the    symbol * is located inside the supply terminal box or
                compartment. to reduce the risk of electric shock, this terminal must be
                connected to the grounding means provided in the electric supply service
                panel with continuous copper wire equivalent in size to the circuit
                conductors that supply this equipment. *IeC Publication 417, symbol
                5019.

       3.        at least two lugs marked “Bonding lugs” are provided on the external
                 surface or on the inside of the supply terminal box/compartment. to
                 reduce the risk of electric shock, connect the local common bonding grid
                 in the area of the hot tub to these terminals with an insulated or bare
                 copper conductor..

       4.        all field installed metal components such as rails, ladders, drains, and
                 other similar hardware within 10 feet (3m) of the hot tub shall be bonded
                 to equipment grounding buss with copper conductors..


       5.        saVe tHese InstRuCtIons.




                                               9
LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 10




                            Location - Choosing the
                           perfect place for your spa.

                       it’s not only the location - but also the Foundation

   Proper placement of your spa is key not only to enjoying it, but also taking care of it. after all, it’s a substantial
   investment that you want to take care of so it will continue to bring years of enjoyment. wherever you choose
   to place you spa, there are some basics that must be followed.

   Consider the weight of the spa. you must have the proper foundation to support not only its dry weight, but
   also its filled weight. structural damage that occurs to your spa that results from an inadequate foundation is
   not covered under your warranty so it’s important that you follow the manufacturer’s guidelines.

   the manufacturer recommends that your laguna Bay spa be placed on a reinforced concrete pad that is at
   least four inches thick and large enough to accommodate the entire spa. the concrete should cure for a
   minimum of 72 hours before placing the spa on the pad. you should place your spa so the electronics and
   circuit breakers are easily accessible. and remember that the electronics must be kept dry, so drainage of water
   away from the spas foundation is important. the spa must not be placed in the way of landscaping sprinklers
   to ensure there is no damage to the skirt or frame of the spa.

   Inquire with local officials about building codes, electrical and plumbing codes.. think about the desired
   proximity to the doors of the house especially in cold weather,. Be sure there is a pathway that can be easily
   maintained and is free from debris. try to keep your spa away from roof overhangs and guttering to increase
   the life of the spa cover. when choosing the location for your spa, try to remember the effects of wind,
   exposure to the sun and the location of trees to minimize the effects of falling debris and shade.

   If you choose to place your spa on a deck, ask a licensed contractor or engineer to determine the deck’s
   maximum load bearing capacity. the weight per square foot must not exceed that limit or the result will be
   serious structural damage to the deck and the spa. If you are considering a recessed spa in your deck or floor,
   be sure there is access to the electrical equipment and other components in the rare case that your spa may
   require servicing. Make sure there is adequate room to remove all exterior panels, with special attention paid to
   the side where the electrical components are located.

   If you are placing your spa indoors or in a basement, choose a floor covering that will hold up well to the water
   that will inevitably sit around the spa. floor covering should be slip resistant with some ability to grip when the
   floor is wet. there must be adequate drainage away from the spa. the location and floor covering must be
   able to handle draining of the entire spa. Humidity should be considered, as should moisture to the wood,
   paper, drywall, and any mold and mildew which accompanies humid areas of the home. some spa chemicals
   may have an adverse reaction to some household metals. you should consider installing a ventilation system to
   address these issues. again, adequate support for the weight of the spa is vital.
   do:
   Following all procedures in the owner’s Guidebook and water care products (chemical) packaging.
   test the water regularly to ensure the chemical balance is correct.
   drain, clean, and refill your spa with fresh water regularly in accordance with the owner’s Guidebook.
   Clean the filters a minimum of once a month.
   ensure proper water circulation.
   Always bathe or shower before entering the spa.

                                     proper maintenance of filters, water chemistry,
                                     and ventilation reduces the risk of exposure to
                                     viruses and bacteria that may be present in the
                                     water and in the air.
                                                            10
LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 11




                                   Location - Choosing the
                                  perfect place for your spa.




             Manufacturer’s preferred site preparation
       the concrete pad should be 4” (7.6 cm) thick sloping 1/2” (1.3 cm) per 10 feet (305 cm) so rain and
       runoff will not puddle on the underside of the spa for long periods causing the frame to deteriorate.




                                          improper site preparation
         water “self levels”. If a spa is placed on grass, dirt, pea gravel, stones or brick, they can shift
         causing the spa to be out of level. It is important to remember that your warranty does not cover
         spas that are not properly placed on a level, well prepared foundation.


             How to Install Cover Locks
                                                                            Cover lock installation
                                                   Cover
                                                                    Put the spa cover on the spa.
                                                                    Position the tie down locks on the spa cabinet so they
                                              Tie Down Straps
                                                                    can easily reach the tie down straps. allow
                                               Cover Lock and Key   approximately 3/4 inch slack in the straps so there is
                                                                    ample room for the clip to slide easily into the lock
                                              2 Screws              when there are variations in the weather.
                                                                    attach the locks with screws.
                                                                      never leave the spa uncovered and
                                                                      unattended.
                                                                      never leave the spa cover unlocked.
                                                                      do not sit, stand or lie on the cover.
                                                                       11
LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 12




                              Electrical Information




             Avoid the Risk oF eleCtRoCUtion.
        lAgUnA BAy spAs ReCoMMends thAt eleCtRiCAl
            CoMponents Be instAlled only By A
                    liCensed eleCtRiCiAn.
   All eleCtRiCAl ConneCtions MUst Be peRFoRMed By A QUAliFied liCensed
   eleCtRiCiAn in ACCoRdAnCe With the nAtionAl eleCtRiCAl Code (neC) And
   With stAte And loCAl eleCtRiCAl Codes in eFFeCt At the tiMe oF the
   instAllAtion. ConneCting the spA to An iMpRopeRly WiRed CiRCUit Will
   eliMinAte MAny oF the spA’s BUilt in sAFety FeAtURes WhiCh MAy ResUlt in
   FiRe, eleCtRoCUtion, oR otheR Risk oF injURy. dAMAges to the spA WhiCh
   ARe the ResUlt oF iMpRopeR WiRing ARe not CoveRed UndeR the
   MAnUFACtUReR’s WARRAnty And Will teRMinAte All listings FRoM
   independent listing AgenCies. the eleCtRiCAl diAgRAMs ContAined in this
   MAnUAl ARe inClUded As A gUideline FoR the liCensed eleCtRiCiAn
   instAlling the eleCtRiCAl ConneCtions.
                                   All WiRing MUst Be WAteRtight ! ! !
           neveR tURn poWeR on to the spA When it is not Filled With WAteR !
   Remove the spa from its packaging materials. Retain all warranty, safety and operation materials.
   prior to performing any service to your laguna Bay spa, turn off all primary electrical equipment at
   the main circuit breaker or disconnect panel. your laguna Bay spa must be permanently connected (hard
   wired) to the power supply. no plug in connections, extension cords or surge protectors are to be used in
   conjunction with the operation of your new spa. Power supplied to your laguna Bay spa must be a dedicated
   circuit with no other appliances, lighting, or any other electronic components powered by this circuit.
   there are a few laguna Bay spa models equipped with a 120V Ground fault Circuit Interrupter (GfCI)
   cord attached. If this is what you ordered, the power service requirement is 110 Volt 20a. this service branch is
   to be a dedicated 20 amp circuit, within 15 feet and not closer than 5 feet (1.5m) from the positioning of the spa
   equipment. no plug in connections, extension cords or surge protectors are to be used in conjunction with the
   operation of your new spa. Power supplied to your laguna Bay spa must be a dedicated circuit with no other
   appliances, lighting, or any other electronic components powered by this circuit.
   the electrical supply for this product must be housed in a weatherproof service box and include a
   suitably rated switch or Ground fault Circuit Interrupter between the main service entrance and the spa to open
   all ungrounded supply conductors tin compliance with section 422-20 of the national electrical Code/usa,
   ansI/nfPa/70 and in compliance with underwriters laboratories, Inc.. this might be used as a shut off
   switch, which must be installed so that it is accessible to the spa occupants, but not within 5 feet (1.5m) of the
   spa.
   All connections should be made using copper conductors only. do not use aluminum wire. Connection
   wires, circuit breakers, and/or fuses, must all be sized to accommodate the total ampere load.



                                                         12
LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 13




                              Electrical Information


    to make your laguna Bay spa electrical connections, remove the entire cabinet with the sticker that
    says “ReMoVe tHIs Panel foR eleCtRICal”. In most models you will remove the panel
    underneath the spa’s top side control pad by removing all screws attaching the cabinet panel to the spa frame.

    At this tiMe, hAnd tighten the Unions And ensURe the sliCe vAlves ARe in
    the Up position. iF the sliCe vAlves ARe not in the Up position, open the
    sliCe vAlves And AttACh the Clip loCks With the sliCe vAlves in the Up
    position. RUn yoUR spA And CheCk FoR leAks BeFoRe ReinstAlling
    eXteRioR ACCess pAnel. this shoUld Be done eACh tiMe this pAnel is
    ReMoved.

                   All eleCtRiCAl ConneCtions MUst Be MAde
                           By A liCensed eleCtRiCiAn.

    do not ConneCt poWeR to the eMpty spA. poWeR to the spA
    AUtoMAtiCAlly ACtivAtes CRitiCAl CoMponents Within the spA, sUCh As
    the ContRols And the heAting. iF poWeR is sUpplied to the CoMponents
    pRioR to the spA Being Filled, the CoMponents Will Be dAMAged. dAMAge
    thAt oCCURs to the CoMponents BeCAUse poWeR WAs sUpplied BeFoRe the
    spA WAs Filled With WAteR is not CoveRed By the MAnUFACtUReR’s
    WARRAnty.
                                              220v installation
    Correct wiring of the electrical service box, GfCI box and pack terminal block is required. spas installed for
    220v operation require a 4-wire, 50 amp or 60 amp (depending on the spa model), 220 volt subfeed in non
                                                                    metallic pipe to the spa equipment
                                                                    compartment. a green colored terminal is
       Service                                                      provided in the control box. to reduce the
         Panel                                                      risk of electrical shock, connect this terminal
                                                    GFCI Panel or connector to the grounding terminal of
                                                      located       your electrical service or supply panel with a
                                                      at least      continuous green insulated copper wire. In
                                                   5 feet (1.5m) addition, a second pressure wire connector is
                                                     from spa.      provided on the surface of the control box for
                                                                    bonding to local ground points. to reduce
                                                                    the risk of electrical shock, this connector
                                                                    should be bonded with copper wire to any
                                                                    reinforced concrete, metal water pipes, or any
    metal within 5 feet (1.5m) of the spa. International customers should contact their laguna Bay spas dealer
    for electrical wiring Requirements. Refer to supplied wiring diagrams and call technical support for
    assistance if necessary.

                                   Us and Canadian gFCi Wiring diagram
    the black and red wires from the electrical box must be connected to the input of the GfCI.
    the white wire from the electrical box must be connected to the neutral bus.
    the green or copper wire must be connected to the ground log of the GfCI.
    the black, red and white wires going to the spa must be connected directly to the output of the GfCI.
    the neutral to the GfCI must be connected to the neutral bus.
    the green or copper wire going to the spa must be connected to the ground lug.


                                                         13
LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 14




                                           Electrical Information


                                                                                                    important:
                                                                                                    to allow the 220V GfCI to function
                                                                                                    properly, connect the white neutral wire
       Spa GFCI Breaker Box Wiring
                Breaker Box Wiring                                                                  from the spa to the neutral terminal on
                                                                                                    the GfCI breaker, not the neutral bus in
                           50A GFCI                           50A GFCI                              the GfCI breaker box. an improperly
               To Main
               To Main
                     n                    To
                                          To Spa   To Main
                                                   To Main                   To Spa
                                                                             To Spa
                                                                                  a
                                                                                                    connected neutral causes the GfCI
                                                                                                    breaker to trip.do not replace the
                                                                                                    exterior cabinet panel until your new
                                                                                                    laguna Bay spa has been filled with
                           N      G
                                                             N
                                                                         G
                                                                                                    water. Be sure to hand tighten the
                                                                                                    unions in the plumbing lines and ensure
                                                             E
                           E      N                                      N
                           U                                 U
                                      D                                  D
                                                             T
                                                                                                    the slice valves are locked in the up
                           T



                                                                                                    position at this time. see page 17 for
                                                                                                    reference.


   1. Terminal Block                                                                       1.)Remove the exterior cabinet panel
   2. Bonding Lug
                                                                                           beneath the topside controls.
   3. Grounding Terminal
                                                                                           2.) Remove the screws from the
                                                                                           faceplate of the spa pack.
                                3
                                                                                           3.) Choose one of the available break
                                                               Exterior
                                                                                           away conduit entry points and remove
              2                                              Access Panel
                                                                                           the disc from the desired location.
                                          1                                                4.) Connect the conduit to the Spa Pack
                                                                                           using a water tight connector.
                                                                                           5.) Feed wiring through the conduit
                                                                                           entry points in the spa pack box.


   1.) Remove enough insulation from
   each wire to ensure contact with
                                                                                                         TB3
   screw. Failure to remove insulation
   will cause spa pack to malfunction.
   2.) Connect the electrical service
                                                                                         Green
   wires, color to color, on the terminal                                                               TB1
   blocks TB1 and TB3 located in the
   spa pack box.                                                                          Black 1
                                                                     TB2
   3.) Tighten SECURELY to prevent                                  Power
                                                                                           Neutral
                                                                                      ^^^^^^^^^^^^^^^
   damage.                                                            In                  Red 2
   4.) Replace the spa pack faceplate
   with screws.                                                                                                       To Circuit
                                                                                                                      Board

                                                                                14
LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 15




                                Electrical Information


                                               110 v installation
   all 110 volt laguna Bay spas are delivered with a GfCI power cord that is approximately 15 feet in length.
   electrical service must be no farther than 15 feet (4.5m) and no closer than 5 feet (1.5m) to the spa. do not
   connect the spa using extension cords or surge protectors. the spa must be connected to a dedicated 110v/20a
   GfCI protected, grounded circuit. this circuit must not be used by or shared with any other electrical
   component. If it is connected to a shared circuit, it will overload the circuit leading to tripping at the main
   breaker. failure to connect the spa to a breaker that is not dedicated may result in damage or failure of the
   equipment which is not covered by the manufacturer’s warranty. do not modify the plug in any way in an
   attempt to bypass the manufacturer’s recommendations. alteration of the plug will void the manufacturer’s
   warranty.
   the dedicated circuit must have a 20 amp GfCI in the main breaker panel with ground wire and the correct
   polarity throughout the circuit.
   a pressure wire connector is provided on the exterior surface of the control box, inside the spa. this wire allows
   grounding between this point and any metal equipment, reinforced concrete, metal pipe or water pipes within 5
   feet (1.5m) of the spa. the bonding wire must be solid copper wire.

   if your electrician has questions about the wiring instructions,
   please call laguna Bay spas technical Assistance at (877) 722-
   4097. Factory trained technical service specialists are available
   to answer questions during their normal business hours
   Monday through Friday from 8:30 am to 5 pm est.
   your new laguna Bay spa has been put through rigorous testing during the manufacturing process. It is not
   uncommon that some water may remain in the plumbing after testing and may leave spots on the acrylic finish
   or cabinetry. wipe the spa and cabinet with a clean soft rag. do not use houseold cleaners that contain bleach
   or amonia because they may have an adverse effect on the acrylic surface of the spa and have a negative
   reaction with chemicals used to maintain water chemistry. neVeR use aBRasIVe CleaneRs on you
   sPa BeCause tHey wIll CReate PeRManant sCRatHes on tHe aCRylIC suRfaCe.

                                 do not Apply poWeR to the eMpty spA. poWeR to the spA
                                 ACtivAtes CRitiCAl CoMponents Within the spA, sUCh As
                                 the ContRols And the heAting. iF poWeR is sUpplied to
                                 the CoMponents pRioR to the spA Being Filled, the
                                 CoMponents MAy Be dAMAged. dAMAge thAt oCCURs to
                                 the CoMponents BeCAUse poWeR WAs sUpplied BeFoRe
                                 the spA WAs Filled With WAteR is not CoveRed By the
                                 MAnUFACtUReR’s WARRAnty.
   do:
   Follow the instructions each time you re-fill the spa to ensure successful start up
   Manually turn the gFCi into the “off ” position.
   With the filters removed and the drain valve open, run water through the filtration canister and jet lines until
   the water runs clear. this will remove any incidental dust, dirt and debris that may have accumulated during
   shipping and installation.
   Rinse the inside of the spa with warm water
   Check for obvious signs of freight damage including loose wires or broken pipes.
   Check to see that the unions for the heaters and plumbing are hand tightened.



                                                          15
LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 16




                            Filling Your Spa &
                          Navigating the Hardware
     Check to see that the slice valves are locked in the “uP” position. do not run the spa with the slice
     valves in the closed or down position or with no water in the spa. this will damage the pumps and seals.
     damage that occurs because the spa has been operating with the slice valves in the “closed” position is not
     covered under the manufacturer’s warranty.
     Check to see that all jets, air valves, and the diverter valves are open. do not force them to turn beyond
     the built in stop.
     do not:
     Clean the acrylic surface with cleaners that are not approved by laguna Bay spas, especially houseold
     bleach and ammonia based cleaners commercially manufactured to clean glass.
     Use water that is filtered or from a water softener.
     Fill the spa with hot water. this may damage the spa controls.
     Use the spa until you have completed each of the steps in this section of the owner’s guidebook.
     Add chlorine if treating your spa with polyhexamethylene biguaride [Biguanide, PHMB, (Baquaspa®)].
     leave the spa unattended while the cover and the exterior panels are not in place.
                                Filling & Re-Filling yoUR neW
                                  lAgUnA BAy spA With WAteR
     when you are certain the drain valve is closed, the slice valves are locked in the up position and the unions
     have been hand tightened, remove the floating weir, skimmer basket and filters from the filtration Canister
     of your new laguna Bay spa. Place a garden hose into the empty filtration canister. water will begin filling
     the spa from footwell inside the spa. filling the spa in this manner will allow the pump to partially prime.
     allow water to continue filling the spa until the water level is approximately 4 inches over the filtration
     canister area of the spa. Remove the garden hose and replace the filter, skimmer basket and floating weir.
     Check for leaks inside the cabinet of the spa, especially at the unions for plumbing and heaters and hand
     tighten if necessary. Be sure slice valves are locked in the open position.
     iMpoRtAnt:
     over filling your spa will not allow room for water to displace when people enter the spa and will cause water
     to overflow. under filling the spa will not allow the water to flow properly through the water lines and
     pumps causing a potential air lock or damage to the pumps and heater. damage that occurs because of
     improper water levels is not covered under the manufacturer’s warranty.
     each time you fill your spa, it is a good idea to check the condition of the locks on the slice valves to ensure
     they have not become damaged. at the same time you should check to be sure that all plumbing unions are
     hand tightened. you should not replace the spa cabinet unitl the spa has been filled and power has been
     applied. the cabinet should only be replaced after you are sure all the pumps and jets are in proper working
     order. If you decide to replace the screws on the cabinet, they should be replaced only with stainless steel
     screws which will not rust.


                                                             The slice valves located along
                                                              the plumbing lines near the
              Slice Valve                                                unions.
             locked in the up            C                During normal operation, the slice valves should
                 position                                 be locked in the up position. If your spa requires
                                                          service, the slice valves can be closed to seal the
                                                          plumbing and keep the water in the spa. If you
           Pump                                           have low or no water flow, check to be sure the
                                                          slice valves are locked in the up position. The
                                 Plumbing                 valve will not stay in the up position without the
                                  Unions                  lock; the force of the pump will pull the valves into
                                                          the closed position if the locks are not in place.


                                                         16
LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 17




                           Filling Your Spa &
                         Navigating the Hardware

                 Side View of Pump
                                                               Skimmer
                                                               S
                Slice Valve                                     & Filter
                                                               Housing
                                                                                  Jet
                                        C
                                                                      Suction               Suction
                                                                       Valve    Footwell     Valve

              Pump
                                 Plumbing
                                  Line In


            Bleeding the Pump
     The pumps on your new Laguna Bay Spa                              Flo ting We
                                                                       Floating We
                                                                         oa
                                                                         o      Weir
                                                                                 eir
     are designed to pump water, not air. If air
                                                                      Sk
                                                                      Sk immer Basket
                                                                      Skimmer Basket
                                                                                   et
                                                                                   e
     is in the plumbing lines when the pumps
     are powered on, the pumps will lock and
     fail to operate properly. You should                   Filter
                                                            Filter
     immediately power off the pumps to avoid               Housing
     damaging your spa.                                                           Filter
                                                                                  Filter
                                                                                    l
                                                            Below
                                                            Below           located fi ter
                                                                             o a d filte
                                                                            located in filter
     To bleed air from the pump, open the bleed
     valve on the front of the pump by turning              Acrylic
                                                            Acrylic         housing belo
                                                                            h u ng be ow
                                                                                       below
     the valve stem in a counter clockwise                 Surface
                                                           Surface           acrylic surface
                                                                             acrylic r c
                                                                             a y c surface
     direction. If you use vice grips, be careful
     not to break the stem off the valve. Water
     will trickle from the valve after the all the
     air has been released. When water trickles                             Filling the Spa
     from the valve, turn the valve stem in a                         Do not put the water hose
     clockwise direction to tighten and close                   inside the acrylic when filling the spa.
     the Bleed Valve.
                                                          Turn the skimmer basket clockwise until it stops.
     You should consider bleeding the air from
     the pumps prior to powering on the GFCI              Remove the filter basket and filter housing. Put the
     each time you fill your spa. Making sure air          water hose into the filter housing. The internal
     is released from the plumbing lines before           plumbing lines will fill with water from the bottom
     they are powered on will ensure the pumps            moving upward. Water will begin entering the spa
     operate properly and will prolong the life           through the suction valves and jets into the footwell.
     of the spa.                                          As the level rises, water will enter through the lowest
                    Front of                              jets to the upper jets. When the water level is 4” above
                Front Pumpof Pump
                      View                                the filter housing, remove the hose. Replace the filter
                                                          and skimmer basket into the filter housing. Lock in
                                                          place by turning counter clockwise until it stops.
                      Plumbing
                         Line
                                                          Filling the spa in this manner allows the plumbing
                          In                              lines to fill with water greatly reducing the risk of
                                                          developing an air lock in the pumps. If water surges
                        Bleed Valve &                     or if you hear a hum when the pump is turned on,
                        Thumb Screw                       there is an air lock in the pump.
                                                          Immediately turn the pump off to avoid damaging spa
                                                          and bleed the air from the pump.


                                                     17
Filling Your Spa &
      Navigating the Hardware




           You
           You can control the intensity of the water flowing
            o       control     intensity       water flo
           from the water fall by rotating the valve loca
           from      waterfall by rotating     valve located on
           the topside of the spa. The water fall will help
               topside              The waterfall
           create a more relaxing spa experience
           create more relaxing         experience.
Off   On
           The waterfall is intended to create ambience and is
           not designed to be load bearing. It should never be
           used as a support or hand rail. Excessive force or
           weight loads may cause injury or break the
           waterfall assembly.
LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 19




                              Filling Your Spa &
                            Navigating the Hardware
                             Understanding the diverter valves
                                    Customizing the force of power in the seating areas
   your new laguna Bay spa was designed to allow customization of your spa experience. By controlling the flow
   of the water through the pumps to the jets you will be able to move water from one area of the spa to another
   and back again. you will also be able to control the flow of the water as it is forced through the jets. the air
   valves, located along the acrylic surface on the top of the spa, increase and decrease the air flow as they are
   rotated between the “open” and “closed” positions. Increasing the air flow by opening the air valves will allow air
   to be forced into the spa creating “bubbles” and increase the intensity of your spa experience. decreasing the air
   flow by closing the air valves will provide a more relaxing spa experience. the flow can be wide open, completely
   closed, or anywhere you choose in between. there are built in “stops” which limit the rotation of the valve.
          do not force the valve past the stop point. it will break the valve and damage the spa.

                           iMpoRtAnt inFoRMAtion ABoUt heAting yoUR spA
        When the heater is on, the red light on top of the heating unit will also be on.
        the actual water temperature will be displayed on the topside controls.
        the high and low water temperatures are preset by the manufacturer. the low temperature is 56ºf.
        the high temperature is 104ºf.
        setting the thermostat to a higher temperature will not cause the water to heat faster. It will only
        result in a higher water temperature.
        the heater operates until the actural water temperature is within 3ºf of thetemperature that is
        programmed and locked into the thermostat, then it will automatically shut off.
        the heater will reactivate when the water temperature drops within 3ºf below the temperature
        programmed and locked into the thermostat.
        the spa is equipped with a state of the art components. Because the spa is equipped with a highly
        advanced heater and is designed for maximum energey effieiency, each time you exti the spa, you should
        reduce the programmed temperature.
        during warm weather, or in very warm climates, you should lower the programmed temperature
        setting to just below you average forecast high temperature. for example, if your average weekly
        forecast high is 88ºf, you should set reduce your temperature setting to 86º or below. when you are
        ready to use your spa, increase the temperature to the desired setting about 30 minutes prior to use.
        in the 110v spa models, the pump is a single speed pump.
        in the 220v electrical configuration, the heater does work simultaneously with the pump on high
        speed. when the heating unit turns on, the pumps will only operate on low speed.
        Repeatedly touching the pump button to override the pre programmed settings and attempting to
        turn the pumps on high speed the while the spa is heating will not turn the pumps on high speed. It will
        instead trip the GfCI, the main breaker and has the potential to damage the spa. damage caused to
        the spa attempting to override the programmed settings with the pump button is not covered under the
        manufacturer’s warranty.

                          getting to know the topside Controls
               the control pad on your spa will vary depending on the model you purchased.
   your laguna Bay spa was created to be one of the most user friendly spas available in the marketplace. until
   now, most spa controls offered some choices but they forced users into an either/or choice. the settings limited
   use and conserving energy made some spa functions non existent. laguna Bay spas are manufactured so you can
   use your spa the way you want to, when you want to. since each button controls one thing, and only one thing,
   you can choose what the spa does and when it does it simply by pressing the correct button.
   once the spa is filled, the electrician has installed the GfCI from your main power supply and has connected the
   wires to the spa pack, reattach the panel door on the spa pack. don’ reattach the cabinet panel just yet. turn
   GfCI into the “on” or “Reset” position. the instructions for your topside controls will vary depending upon
   which laguna Bay spa you purchased. Please refer to the set of instructions matching the topside controls on
   your spa.

                                                          19
LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 20




                              Water Chemistry
      It is imperative to have clean, clear, water. water maintenance will vary depending on many things such
      as quality of your water, how frequently you use your spa, and how many people use the spa. the
      fundamental things to consider when it comes to maintaining the water in your spa are filtration,
      sanitation, and proper balance of chemicals and pH. following a regular schedule will help you achieve
      acceptable water sanitation along with proper levels of total alkalinity and Calcium hardness. It is
      important to remember that bacteria and viruses grow quickly in water that is not properly maintained.
      It is your responsibility to keep your water in proper balance to not only for proper sanitation, but also for
      minimal buildup of deposits and to prolong the life of the spa.
      Basic Chemical safety
      when using chemicals, read the labels and follow the directions. Chemicals are designed to protect you
      and your spa they can be hazardous if not handled correctly.
      do:
      Wait until the water temperature has reached a minimum of 80ºf before adding chemicals
      Wash your hands after handling chemicals. In case of accidental contact, follow the emergency
      advice on the product label.
      keep chemicals in their original container.
      Allow a responsible person to handle spa chemicals.
      keep chemicals away from children and pets.
                                                                      ALKALINE        8.2        ADD pH
                                                                         SPA                 DECREASER
      handle all containers with care.
      store chemicals in a cool, dry, well ventilated place.
                                                                       WATER          7.8 TO LOWER
                                                                   (MAY CAUSE                       pH
      keep chemical containers closed when not in use.
                                                                      SCALING)        7.6
      prooperly Replace caps on their containers.
      if a doctor is needed, take chemical containers with           COMFORT                      IDEAL
                                                                        ZONE
                                                                                      7.4
      you to the hospital so the substances can be identified.
      don’t:
      Add chemicals to water temperatures below 80ºf                    ACIDIC         7.2       ADD pH
      store chemicals in the spa cabinet.                                 SPA                 INCREASER
      Use a vacuum cleaner to clean up chemical spills.                 WATER          6.8          TO
      Allow anyone in the spa while adding chemicals.               (MAY CAUSE                 RAISE pH
      inhale fumes or allow chemicals to come in contact            CORROSION) pH
      with your eyes, nose or mouth.
      Use chlorine tablets (trichlor) in your spa. It can be extremely corrosive. damage caused by use of tri-
      chlor is not covered under the manufacturer’s warranty.
      store Chemicals in extreme temperatures or bright light.
      let chemicals get on surrounding surfaces or landscaping.
      sMoke ARoUnd CheMiCAls. some fumes are highly flammable.
      Use swimming pool chemicals, muratic acid or household bleach in your spa.
        Manufacturer recommended replacement chemicals can be ordered
                 from laguna Bay spas. to place an order visit
          lagunaBayspas.com and click on the link for “spa supplies”
      All spA CheMiCAls MUst Be Added diReCtly into the FilteR
      CoMpARtMent While the pRiMARy pUMp is RUnning FoR A MiniMUM oF
      ten MinUtes With the CoveR oFF the spA. do not leAve the spA
      UnAttended While the spA is UnCoveRed.
      one of the biggest reasons service is needed on spas is because the water chemistry is
      not balanced. too many chemicals will cause deterioration of many of the components in the spa.
      water can accumulate impurities that can impair the performance or even damage the filtration system if
      chemical balance is not maintained. water can become unhealthy if chemicals are not used to sanitize
      water. Improper pH or calcium levels can lead to corrosion and scale build up on integral spa
      components.


                                                           20
LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 21




                              Water Chemistry

     the following guidelines have been established by the association of Pool and spa Professionals:
                              pH                                                7.4 to 7.6
                        Free Chlorine                                        3.0 to 4.0 ppm
                        Free Bromine                                         2.0 to 4.0 ppm
                       Total Alkalinity                                      100 to 120 ppm
                     Calcium Hardness                                        150 to 250 ppm
                                       Adding Chemicals to Water
     it is important to add chemicals only after the water temperature has reached 80ºF to
     prevent damage to the acrylic surface.
     fold back the cover. never leave the spa unattended while the spa cover is not in place. Remove the filter
     basket assembly (see page 17 for instructions). Press the Primary Pump button twice to turn the pump on
     high. Carefully measure the recommended amount of chemical in accordance with the instructions on
     the label. add chemicals through the filtration canister with the primary pump on high speed, allowing
     water to circulate for a minimum of ten minutes with the spa cover off. never leave the spa unattended
     when the cover is off. use care not to splash chemicals onto your hands, into your eyes, onto the spa
     cabinet, or on the acrylic surface of the spa. Replace the lid onto the chemical container. after ten
     minutes, reduce the primary pump speed to low and close and lock the cover.
     WARning: high levels oF sAnitiZeR CAn CAUse disCoMFoRt to eyes,
     lUngs And skin. AlWAys AlloW sAnitiZeR levels to FAll to the
     ReCoMMended levels BeFoRe Using the spA.
     each step in this water maintenance program is dependent of the previous steps.
     omission of a step, or failing to reach the recommended range may cause an imbalance
     in water chemistry. Unbalanced water may lead to damage to the spa and its components
     and discomfort for spa users. damage to the spa caused by improper water chemistry is
     not covered under the manufacturer’s warranty.
     to measure the quality of your spa’s water, immerse the test strip in water, following the instructions on
     the test strip. do not touCH tHe test stRIP wItH youR fInGeRs as It May affeCt
     tHe outCoMe of tHe test Result. Compare the test strip and the label to determine the
     condition of the spa water.
     step 1.) Balancing total Alkalinity (tA)
     the recommended total alkalinity for your spa is between 125 and 150 ppm. the total alkalinity is a
     measure of the total levels of carbonates, bicarbonates, hydroxides and other alkaline substances in the
     water. ta is referred to as the water’s “pH buffer”. It is a measure ot the water’s ability to resist changes
     in the pH level. If the ta is too low, the pH level will fluctuate from high to low. fluctuations in pH can
     cause corrosion or scaling of the spa components. low total Alkalinity can be corrected by
     adding sodium hydrogen carbonate (ph/Alkalinity Up).
     step 2.) Balancing Calcium hardness (Ch)
     the recommended calcium hardness (CH) level for your spa is 150-200 ppm. Calcium Hardness is a
     measurement of the total amount of dissolved calcium in the water. Calcium helps control the corrosive
     nature of the spa’s water. Calcium-low water (commonly known as “soft” water) is not recommended. It
     is hightly corrosive to the spa and the spa components and can cause staining of the spa shell. If the CH
     is too high (commonly known as “hard”water),formation of scale on the spa and the spa components can
     result. Ch can be decreased by dilution - a mixture of 75% “hard” water and 25% “soft”
     water will usually yield a reading of the correct range. If “soft” water is not available or
     practical for you, a stain and scale inhibitor should be added to the water, according to the label
     instructions. If CH is too low, add a CH increaser. once the CH is balanced, it normally remains stable.
     adding more water with a low or high calcium content will raise or lower the CH reading of the water.
     when the Calcium Hardness is within recommended range, proceed to the next step.
                                                          21
LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 22




                              Water Chemistry


     step 3.) Balancing the ph
     It is imperative to have a slightily alkaline pH level for your spa water between 7.4 - 7.6. Problems become
     proportionately severe the further outside the range the water gets. the pH level is the measure of the
     acidity and the alkalinity. Values above 7 are alkaline; those below 7 are acidic. Maintaining proper pH
     level is extremely important for optimizing the effectiveness of sanitizer, maintaining water the is
     comfortable for the user, and preventing equipment deterioration.
     If the spa water’s pH level is too low, the sanitizer will dissipate rapidly, the water may become irritating to
     users, and the spa’s equipment may corrode. if the ph is too low, it can be increased by adding
     sodium hydrogen carbonate (ph/Alkalinity Up to the spa water.
     If the pH level is too high, the sanitizer is less effective, scale may form on the spa and the spa components,
     the water may become cloudy and filter cartridge pores will become clogged and obstructed. if the ph is
     too high, it can be decreased by adding sodium bisulfate (ph/Alkalinity down) to the spa
     water.
     after adding sodium hydrogen carbonate or sodium bisulfate, WAit tWo hoURs before testing the
     water’s pH levels again. Measurements taken too soon may not be accurate. It is important to check the
     pH level on a weekly basis. the pH will be affected by the bather load, the addition of new water, the
     addition of chemicals and the type of sanitizer used. when the pH is within the recommended range,
     proceed to the final step.
     step 4.) Maintaining the sanitizer levels
     sanitizer is extremely important for killing algae, bacteria and viruses and preventing unwanted organisms
     from growing in the spa. at the same time, you don’t want too high a sanitizer level since it may cause
     irritation to the skin, lungs and eyes. always maintain the sanitizer level in your spa at the recommended
     level for each type of sanitizer.
     to keep sanitizer levels in the desired range you should check the bromine, shock, and pH levels level
     before each use and no less than twice each week even if the spa is not in use.
     do not use tri-chlor chlorine, bromo-chlor-dimethyl-hydantoin (BCdMh) or any type of
     compressed bromine or chlorine, acid or any sanitizer not recommended by laguna Bay
     spas.
                                 heavy Cleaning or decontamination
     on occasion, it may be necessary to “super sanitize” your spa. If algae develops, simply draining and
     refilling the spa will not kill the algae. It will be necessary for you to decontaminate the spa before it is
     refilled. during the decontamination process, excessive chemical vapors are produced. Keep children and
     pets away from the spa. wear gloves and a protective mask during the decontamination process. Remove
     the spa cover, all pillows from the spa and protect the plastic valves. If your spa is indoors, open the
     windows and doors. use a fan to circulate the air and force the vapors out of the room.
     Remove the filter basket assembly and filter (see page 17 for instructions). Before adding chemicals, make
     sure all pumps are operable. Check to be sure all jets and air valves are open. Be certain the diverter
     valves are in the center position allowing even circulation through all sections of the spa.
     with all pumps on low speed, add 2.5 ounces of sodium dichlor for every 100 gallons of water in the spa.
     for example, if there are 400 gallons of water in your spa, add 10 ounces of sodium dichlor. after all the
     sodium di-Chlor has been added turn all pumps on their highest speed and allow the water to circulate for
     one hour. do not replace the cover over the spa during decontamination. never leave the spa
     unattended while it is uncovered.
     after allowing the spa to run for one hour, press the safety start button and turn off the spa. turn the
     GfCI off and drain the spa. follow the procedure to refill the spa (instructions begin on page 16) and
     begin add chemicals as needed for proper water chemistry. a new filter should be used each time you drain
     and refill your spa.


                                                           22
LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 23




                              Water Chemistry


                                  Common sense Water Chemistry
     Chemicals are added to your water for your safety. without chemicals, the warm water in your spa is the
     perfect environment for germs, bacteria and other living organisms. Chemicals added to your spa water
     are utilized as they destroy the bacteria from dead skin cells, sweat and other body fluids. Consistent
     addition of sanitizers kept at constant levels keep your water clear and safe to use.
         the water in your laguna Bay spa and your filter should be replaced every 3 months.
     what is required to maintain proper water chemistry is different in every spa and for every spa user. your
     water chemistry changes constantly requiring you make to adjustments. when it’s warm outside,
     chemicals evaporate faster than when the weather is cold. using the spa once a day will require more
     chemicals than using the spa once a week. what it takes to balance your water chemistry in January will
     be different than what it takes in July. the major considerations in water chemistry are:
                                    the number of gallons of water in the spa
                                       the number of people using the spa
                                   the number of hours the spa is being used
     In short, more water used by more people for more hours means more chemicals. whether you use the
     spa or not, you should test your water twice a week. Regularly testing water allows you to make
     adjustments before levels are out of control. when it comes to chemicals, more is not better. adding
     chemicals changes the pH, changes in the pH changes the way the chemicals react. the addition of too
     many chemicals makes the problem worse making your only option to drain the spa and start over.
              When adding chemicals, always read and follow the instructions on the label.
                Always verify that before use that additives will not have an adverse effect.
                            never change sanitizers without first draining the spa.
     afteR addInG sHoCK to youR sPa, leaVe tHe CoVeR oPen foR a MInIMuM of
     20 MInutes to allow tHe oXIdIZeR Gas to Vent. never leave the spa unattended
     while it is uncovered.
     ozone generators
     your spa may have come with an optional ozonator which will do a good job at killing bacteria and
     oxygenating water, but it will not sanitize the water. you must use bromine in tandem with the ozone
     generator. the ozone generator is designed to make chemicals more efficient and water chemistry
     maintenance easier. ozone is a gas that oxidizes contaminants and disinfects bacteria. the ozone
     generator injects ozone while the water is in the plumbing before it comes through the jets and into the
     spa.
     Chlorine generators
     your spa may have come with an optional salt system, also known as a chlorine generator. this system is
     designed to maintain water chemistry by converting salt into the sanitizer without the use of bromine and
     shock. since the system does not create any residual chlorine, water testing will not provide an accurate
     assessment of sanitation levels. test strips should be used to maintain adequate levels of alkalinity, pH and
     water hardness.




                                                         23

Weitere ähnliche Inhalte

Was ist angesagt?

70 0 Avr 3803 En
70 0 Avr 3803 En70 0 Avr 3803 En
70 0 Avr 3803 En
guestaee4e0
 
Yst Rsw300 Final
Yst Rsw300 FinalYst Rsw300 Final
Yst Rsw300 Final
arxxx
 
2012 legecy owner's manual
2012 legecy owner's manual2012 legecy owner's manual
2012 legecy owner's manual
Master Spa Parts
 
MMP Series Manual - Revised
MMP Series Manual - RevisedMMP Series Manual - Revised
MMP Series Manual - Revised
tyentusa
 

Was ist angesagt? (19)

Sears bh9430pw-users-manual-399058 (1)
Sears bh9430pw-users-manual-399058 (1)Sears bh9430pw-users-manual-399058 (1)
Sears bh9430pw-users-manual-399058 (1)
 
JVC SR-HD1350EU Blu-ray recorder + 250GB HDD
JVC SR-HD1350EU Blu-ray recorder + 250GB HDDJVC SR-HD1350EU Blu-ray recorder + 250GB HDD
JVC SR-HD1350EU Blu-ray recorder + 250GB HDD
 
June 2011 Newsletter
June 2011 NewsletterJune 2011 Newsletter
June 2011 Newsletter
 
swim spas
swim spasswim spas
swim spas
 
70 0 Avr 3803 En
70 0 Avr 3803 En70 0 Avr 3803 En
70 0 Avr 3803 En
 
H2
H2H2
H2
 
Yst Rsw300 Final
Yst Rsw300 FinalYst Rsw300 Final
Yst Rsw300 Final
 
Dmix 300 Manual
Dmix 300 ManualDmix 300 Manual
Dmix 300 Manual
 
Avtron IR Bullet Camera Aa 4544-6044 p-fsr2-manual
Avtron IR Bullet Camera Aa 4544-6044 p-fsr2-manualAvtron IR Bullet Camera Aa 4544-6044 p-fsr2-manual
Avtron IR Bullet Camera Aa 4544-6044 p-fsr2-manual
 
2012 legecy owner's manual
2012 legecy owner's manual2012 legecy owner's manual
2012 legecy owner's manual
 
Optio w80 no-pw
Optio w80 no-pwOptio w80 no-pw
Optio w80 no-pw
 
MMP Series Manual - Revised
MMP Series Manual - RevisedMMP Series Manual - Revised
MMP Series Manual - Revised
 
Avtron IR Bullet Camera Aa 4545 p-6045-fsr3-manual
Avtron IR Bullet Camera Aa 4545 p-6045-fsr3-manualAvtron IR Bullet Camera Aa 4545 p-6045-fsr3-manual
Avtron IR Bullet Camera Aa 4545 p-6045-fsr3-manual
 
85 0100 a universal air operation (1000-9000)
85 0100 a universal air operation (1000-9000)85 0100 a universal air operation (1000-9000)
85 0100 a universal air operation (1000-9000)
 
Er 230 au user manual
Er 230 au user manualEr 230 au user manual
Er 230 au user manual
 
Avtron IR Bullet Camera Aa 4547 p-6047-fsr4-manual
Avtron IR Bullet Camera Aa 4547 p-6047-fsr4-manualAvtron IR Bullet Camera Aa 4547 p-6047-fsr4-manual
Avtron IR Bullet Camera Aa 4547 p-6047-fsr4-manual
 
01 gt 100-e03_w
01 gt 100-e03_w01 gt 100-e03_w
01 gt 100-e03_w
 
Owners manual
Owners manualOwners manual
Owners manual
 
Yinhe 808 user manual
Yinhe 808 user manualYinhe 808 user manual
Yinhe 808 user manual
 

Ähnlich wie Laguna Bay Spa manual

Roland MdX 40 Manual d'usuari
Roland MdX 40 Manual d'usuariRoland MdX 40 Manual d'usuari
Roland MdX 40 Manual d'usuari
esclatec
 
COV34636825_Owners_Manual_Non_WiFi_Rev.0_v0_English.pdf
COV34636825_Owners_Manual_Non_WiFi_Rev.0_v0_English.pdfCOV34636825_Owners_Manual_Non_WiFi_Rev.0_v0_English.pdf
COV34636825_Owners_Manual_Non_WiFi_Rev.0_v0_English.pdf
UyenNguyen129868
 
TyentUSA MMP Series User's Manual
TyentUSA MMP Series User's ManualTyentUSA MMP Series User's Manual
TyentUSA MMP Series User's Manual
tyentusa
 

Ähnlich wie Laguna Bay Spa manual (20)

MASTER SPAS TWILIGHT OWNER’S MANUAL
MASTER SPAS TWILIGHT OWNER’S MANUALMASTER SPAS TWILIGHT OWNER’S MANUAL
MASTER SPAS TWILIGHT OWNER’S MANUAL
 
850077 a outdoor operation
850077 a outdoor operation850077 a outdoor operation
850077 a outdoor operation
 
Four Person Hot Tubs Spas
Four Person Hot Tubs SpasFour Person Hot Tubs Spas
Four Person Hot Tubs Spas
 
Master Spa Legend Owner's Manual
Master Spa Legend Owner's ManualMaster Spa Legend Owner's Manual
Master Spa Legend Owner's Manual
 
85 0100 a-p universal air operation (300-500)
85 0100 a-p universal air operation (300-500)85 0100 a-p universal air operation (300-500)
85 0100 a-p universal air operation (300-500)
 
Manual HMC40.pdf
Manual HMC40.pdfManual HMC40.pdf
Manual HMC40.pdf
 
85 0100 a-rev 1_univ air operation_web
85 0100 a-rev 1_univ air operation_web85 0100 a-rev 1_univ air operation_web
85 0100 a-rev 1_univ air operation_web
 
sr6007_owners_manual.pdf
sr6007_owners_manual.pdfsr6007_owners_manual.pdf
sr6007_owners_manual.pdf
 
Aquasential Reverse Osmosis
Aquasential Reverse OsmosisAquasential Reverse Osmosis
Aquasential Reverse Osmosis
 
Kystal Clear Model 603 filter pump Manual for Intex Pools
Kystal Clear Model 603 filter pump Manual for Intex PoolsKystal Clear Model 603 filter pump Manual for Intex Pools
Kystal Clear Model 603 filter pump Manual for Intex Pools
 
P4460 manual
P4460 manualP4460 manual
P4460 manual
 
Roland MdX 40 Manual d'usuari
Roland MdX 40 Manual d'usuariRoland MdX 40 Manual d'usuari
Roland MdX 40 Manual d'usuari
 
STANLEY FATMAX J7 CS Jump Starter User Manual
STANLEY FATMAX J7 CS Jump Starter User ManualSTANLEY FATMAX J7 CS Jump Starter User Manual
STANLEY FATMAX J7 CS Jump Starter User Manual
 
manual de tv zenith H1934y (1)
manual de tv zenith H1934y (1)manual de tv zenith H1934y (1)
manual de tv zenith H1934y (1)
 
Krystal Clear Model 637R filter Pump Manual for Intex and bestway swimming pools
Krystal Clear Model 637R filter Pump Manual for Intex and bestway swimming poolsKrystal Clear Model 637R filter Pump Manual for Intex and bestway swimming pools
Krystal Clear Model 637R filter Pump Manual for Intex and bestway swimming pools
 
Opblaasbare jacuzzi
Opblaasbare jacuzziOpblaasbare jacuzzi
Opblaasbare jacuzzi
 
COV34636825_Owners_Manual_Non_WiFi_Rev.0_v0_English.pdf
COV34636825_Owners_Manual_Non_WiFi_Rev.0_v0_English.pdfCOV34636825_Owners_Manual_Non_WiFi_Rev.0_v0_English.pdf
COV34636825_Owners_Manual_Non_WiFi_Rev.0_v0_English.pdf
 
Crystal Clear pool pump model 637R Manual
Crystal Clear pool pump model 637R ManualCrystal Clear pool pump model 637R Manual
Crystal Clear pool pump model 637R Manual
 
TyentUSA MMP Series User's Manual
TyentUSA MMP Series User's ManualTyentUSA MMP Series User's Manual
TyentUSA MMP Series User's Manual
 
Intex krystalClear Pool Pump manual model 603 for Intex and Bestway swimming ...
Intex krystalClear Pool Pump manual model 603 for Intex and Bestway swimming ...Intex krystalClear Pool Pump manual model 603 for Intex and Bestway swimming ...
Intex krystalClear Pool Pump manual model 603 for Intex and Bestway swimming ...
 

Kürzlich hochgeladen

call Now 9811711561 Cash Payment乂 Call Girls in Dwarka Mor
call Now 9811711561 Cash Payment乂 Call Girls in Dwarka Morcall Now 9811711561 Cash Payment乂 Call Girls in Dwarka Mor
call Now 9811711561 Cash Payment乂 Call Girls in Dwarka Mor
vikas rana
 

Kürzlich hochgeladen (15)

Pokemon Go... Unraveling the Conspiracy Theory
Pokemon Go... Unraveling the Conspiracy TheoryPokemon Go... Unraveling the Conspiracy Theory
Pokemon Go... Unraveling the Conspiracy Theory
 
LC_YouSaidYes_NewBelieverBookletDone.pdf
LC_YouSaidYes_NewBelieverBookletDone.pdfLC_YouSaidYes_NewBelieverBookletDone.pdf
LC_YouSaidYes_NewBelieverBookletDone.pdf
 
(Aarini) Russian Call Girls Surat Call Now 8250077686 Surat Escorts 24x7
(Aarini) Russian Call Girls Surat Call Now 8250077686 Surat Escorts 24x7(Aarini) Russian Call Girls Surat Call Now 8250077686 Surat Escorts 24x7
(Aarini) Russian Call Girls Surat Call Now 8250077686 Surat Escorts 24x7
 
WOMEN EMPOWERMENT women empowerment.pptx
WOMEN EMPOWERMENT women empowerment.pptxWOMEN EMPOWERMENT women empowerment.pptx
WOMEN EMPOWERMENT women empowerment.pptx
 
2k Shots ≽ 9205541914 ≼ Call Girls In Jasola (Delhi)
2k Shots ≽ 9205541914 ≼ Call Girls In Jasola (Delhi)2k Shots ≽ 9205541914 ≼ Call Girls In Jasola (Delhi)
2k Shots ≽ 9205541914 ≼ Call Girls In Jasola (Delhi)
 
8377087607 Full Enjoy @24/7-CLEAN-Call Girls In Chhatarpur,
8377087607 Full Enjoy @24/7-CLEAN-Call Girls In Chhatarpur,8377087607 Full Enjoy @24/7-CLEAN-Call Girls In Chhatarpur,
8377087607 Full Enjoy @24/7-CLEAN-Call Girls In Chhatarpur,
 
2k Shots ≽ 9205541914 ≼ Call Girls In Palam (Delhi)
2k Shots ≽ 9205541914 ≼ Call Girls In Palam (Delhi)2k Shots ≽ 9205541914 ≼ Call Girls In Palam (Delhi)
2k Shots ≽ 9205541914 ≼ Call Girls In Palam (Delhi)
 
$ Love Spells^ 💎 (310) 882-6330 in West Virginia, WV | Psychic Reading Best B...
$ Love Spells^ 💎 (310) 882-6330 in West Virginia, WV | Psychic Reading Best B...$ Love Spells^ 💎 (310) 882-6330 in West Virginia, WV | Psychic Reading Best B...
$ Love Spells^ 💎 (310) 882-6330 in West Virginia, WV | Psychic Reading Best B...
 
Top Rated Pune Call Girls Tingre Nagar ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated  Pune Call Girls Tingre Nagar ⟟ 6297143586 ⟟ Call Me For Genuine Se...Top Rated  Pune Call Girls Tingre Nagar ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Tingre Nagar ⟟ 6297143586 ⟟ Call Me For Genuine Se...
 
9892124323, Call Girls in mumbai, Vashi Call Girls , Kurla Call girls
9892124323, Call Girls in mumbai, Vashi Call Girls , Kurla Call girls9892124323, Call Girls in mumbai, Vashi Call Girls , Kurla Call girls
9892124323, Call Girls in mumbai, Vashi Call Girls , Kurla Call girls
 
The Selfspace Journal Preview by Mindbrush
The Selfspace Journal Preview by MindbrushThe Selfspace Journal Preview by Mindbrush
The Selfspace Journal Preview by Mindbrush
 
2k Shots ≽ 9205541914 ≼ Call Girls In Mukherjee Nagar (Delhi)
2k Shots ≽ 9205541914 ≼ Call Girls In Mukherjee Nagar (Delhi)2k Shots ≽ 9205541914 ≼ Call Girls In Mukherjee Nagar (Delhi)
2k Shots ≽ 9205541914 ≼ Call Girls In Mukherjee Nagar (Delhi)
 
call Now 9811711561 Cash Payment乂 Call Girls in Dwarka Mor
call Now 9811711561 Cash Payment乂 Call Girls in Dwarka Morcall Now 9811711561 Cash Payment乂 Call Girls in Dwarka Mor
call Now 9811711561 Cash Payment乂 Call Girls in Dwarka Mor
 
(Anamika) VIP Call Girls Navi Mumbai Call Now 8250077686 Navi Mumbai Escorts ...
(Anamika) VIP Call Girls Navi Mumbai Call Now 8250077686 Navi Mumbai Escorts ...(Anamika) VIP Call Girls Navi Mumbai Call Now 8250077686 Navi Mumbai Escorts ...
(Anamika) VIP Call Girls Navi Mumbai Call Now 8250077686 Navi Mumbai Escorts ...
 
2k Shots ≽ 9205541914 ≼ Call Girls In Dashrath Puri (Delhi)
2k Shots ≽ 9205541914 ≼ Call Girls In Dashrath Puri (Delhi)2k Shots ≽ 9205541914 ≼ Call Girls In Dashrath Puri (Delhi)
2k Shots ≽ 9205541914 ≼ Call Girls In Dashrath Puri (Delhi)
 

Laguna Bay Spa manual

  • 1. LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 1 L aGuna B ay S paS Get Away... Every Day. Owner’s Guide Book
  • 2. LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 2 Important information about your LaGuna Bay Spa Spa Model Spa Serial number Date of purchase Dealer name Ozone Generator yes no prozone System yes no Chemicals used Filter Information Length Width Keeping this information on hand will help if you ever need technical assistance. It is also helpful if you can provide pictures for the technician. pictures allow the technician to see the area of concern as if looking at it along side you. Taking pictures before calling technical support will help expedite resolution - you will be able to email the pictures directly to the technician while you are on the call. For technical assistance, please call 877.722.4097 Technical Support is available Monday through Friday from 8:30 am to 5:00 pm Eastern Standard Time 2
  • 3. LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 3 Index Important Safety Information Begins on Page 4 playing it safe while you play Location Information Begins on Page10 The “Wheres” and “Hows” of choosing and preparing the best place for your new spa Electrical Information begins on Page 12 The magnetic relationship with your spa shouldn’t come with a shock Information about hardware & filling your spa begins on page 16 putting the right water in the right way makes a big difference. Water Chemistry Information begins on page 20 Chrystal clear instructions for chrystal clear water 3
  • 4. LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 4 Important Safety Information Read and CaRefully follow InstRuCtIons ! Basic safety precautions must be followed including: Avoiding the Risk to ChildRen dAngeR: Risk of Children drowning. extreme caution must be used to prevent unauthorized access by children. to avoid accidents, ensure that children cannot use a spa unless they are supervised at all times. WARning: to reduce risk of injury, do not allow children to use this product unless they are closely supervised at all times. to reduce the risk of injury, lower water temperature when spa is used by children. lower water temperatures are recommended since children are especially sensitive to hot water. do: Make sure you always lock child resistant locks after using the spa for your children’s safety. every laguna Bay spa is equipped with a locking cover that meets the atsM f1346-91 standard for safety Covers. there is no representation that the use of the cover, locking clips or actual locks will not prevent access to the spa. test the water temperature with your hands before allowing children to enter the spa to be sure that it’s comfortable. Children are especially sensitive to hot water. Remind children that wet surfaces are slippery. Make sure that children are careful when entering and exiting the spa. Check with local authorities regarding fencing requirements for spas in you area. don’t: Allow children or pets on the spa cover. Covers are strong enough to withstand the weight of tone foot of snow. they are not designed to support the weight of people or pets. sitting on the cover may cause the foam inners to break. Allow children to have unsupervised access to the spa. Avoiding the Risk oF eleCtRoCUtion lAgUnA BAy spAs ReCoMMends thAt eleCtRiCAl CoMponents Be instAlled only By A liCensed eleCtRiCiAn. to ensure the spa functions properly and to ensure your warranty is not compromised by improper installation, you must have a licensed electrician install all electrical components. 4
  • 5. LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 5 Important Safety Information Risk oF eleCtRoCUtion Connect only to a grounded source. if your spa model is equipped with a cord, do not bury the cord. a buried cord may result in death or serious injury due to electrocution if direct burial-type cable is not used, or if improper digging occurs. install at least five feet (1.5m ) from all metal surfaces. If this is not possible, a ground terminal (pressure wire connector) is provided on the control box inside the unit to permit connection with solid copper bonding conductor between this point and any metal equipment, metal water pipe, metal enclosures of electrical equipment, or conduit within five feet (1.5m) and within sight of the spa. do not permit any electrical appliances, such as lights, telephones, radios or televisions within five feet (1.5m) of the spa unless they were built in by the manufacturer. failure to maintain a safe distance may result in death or serious injury from electrocution if the appliance should fall into the spa. WARning to reduce the risk of electric shock, if your spa is equipped with a cord, replace damaged cord immediately. failure to do so may result in death or serious permanent injury by electrocution. your spa requires a ground Fault Circuit interrupter for user and equipment protection in compliance with section 680-42 of the national electrical Code, ansI/nfPa 70-1993. to ensure proper operation of the important safety device, test according to the following instructions with regard to your electrical configuration: Cord-Connected 115 volt, 20 amp: the GfCI is located at the end of the power cord. Before each use, with the unit operating, push the “test” button. the unit should stop operating and the GfCI power indicator will go out. wait 30 seconds and then reset the GfCI by pushing the “Reset” button. the GfCI power indicator will turn on, restoring the power to the spa. If the interrupter does not perform in this manner, there may be an electrical malfunction and with it, the possibility of an electric shock. disconnect the power until the problem has been corrected. Please note this action will automatically reset the filter cycle of the spa. 220 volt, permanently installed or converted models: a ground terminal is provided on the terminal block located inside the control box. to reduce the risk of electric shock, connect the terminal to the grounding terminal of your electrical service or supply panel with a continuous green, insulated copper wire. a bonding terminal (pressure wire connector) is provided on the outside of the control box for bonding to local ground points. to reduce the risk of electric shock, this connector should be bonded with solid copper wire to any metal ladders, water pipes, or other metal within five feet (1.5m) of the spa to comply with local requirements. the means of disconnection must be readily accessible, but must be installed at least five feet (1.5m) from the spa. do: Make sure your spa is properly connected - Use A liCensed eleCtRiCiAn disconnect the spa from the power supply before draining and servicing components. test the ground Fault interrupter(s) before each use. don’t Use the spa with the equipment compartment door removed. Replace components except with identical components supplied by the manufacturer. operate audio or video equipment while inside the spa unless it is with the remote approved or provided by the manufacturer. do not connect auxiliary components (i.e. headphones) to the system. place electrical appliances within five feet (1.5m) of the spa. Use an extension cord to connect the spa to its power source. the cord may not be properly grounded and the connection is a shock hazard. an extension cord may cause a voltage drop, which will cause overheating of the pump(s), cause motor damage and will void the manufacturer’s warranty. Attempt to open the electrical control box. there are no serviceable parts inside the box. 5
  • 6. LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 6 Important Safety Information AvoidABle Risks dAngeR: Risk oF injURy the suction fittings in this spa are sized to match the specific water flow created by the pump. If it is necessary to replace the suction fittings or the pump, be sure the flow rates are compatible. Because of the risk of injury, never operate the spa if the suction fittings are broken or missing. Please contact your dealer or nearest service center for service or repair. never operate the spa if the floating weir(s), filter(s), filter lid(s) or skimmer(s), or skimmer assembly(s) are missing. Please contact your dealer or nearest service center for service or repair. never replace suction fitting with one rated less than the flow rate marked on the original suction fitting. do not remove floating weir(s), basket(s) or filter(s) while spa is running. keep all loose articles of clothing, hair or hanging jewelry away from suction fittings, rotating jets or other moving components. exercise care when entering and exiting the spa. wet surfaces can be slippery. inCReAsed side eFFeCts oF MediCAtion the use of drugs, alcohol, or medication before or during spa use may lead to unconsciousness with the possibility of drowning. persons using medication should consult a physician before using a spa; some medication may cause a user to become drowsy, while other medication may affect the heart rate, blood pressure or circulation. persons taking medications which induce drowsiness, such as tranquilizers, antihistamines or anticoagulants should not use a spa. heAlth pRoBleMs AFFeCted By spA Use pregnant or possibly pregnant women should consult a physician before using a spa. persons suffering from obesity or with a medical history of heart disease, low or high blood pressure, circulatory problems, infectious diseases, immune deficiencies, infectious diseases, infections skin irritations, or diabetes should consult a physician before using a spa. Always shower before and after using a spa. to reduce the possibility of contracting a waterborne illness, always maintain water chemistry within the parameters in this manual. If other bathers are affected by such a condition, discontinue use and consult a physician. UnCleAn WAteR keep the water clean and sanitized with correct chemical care to help maintain safe water and prevent possible damage to spa components. the recommended levels for your laguna Bay spa are: free available Chlorine (faC): 3.0 to 5.0 ppm total alkalinity 125 to 150 ppm water pH: 7.4 to 7.6 Calcium Hardness 150 to 200 ppm Refer to water Quality and Maintenance section for further information and complete instructions about water and spa care. 6
  • 7. LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 7 Important Safety Information iMpoRtAnt: turn jet pump on for at least ten minutes after adding Any spa water chemicals into the filter compartment. Clean the filter cartridge monthly to remove debris and mineral buildup which may affect the performance of hydrotherapy jets, limit the water flow, or trip the high limit thermostat which will turn off the entire spa to prevent further damage to the spa. Avoiding the Risks oF hypeRtheRMiA prolonged immersion in hot water can result in HyPeRtHeRMIa, a dangerous condition which occurs when the internal temperature of the body reaches a level above normal (98.6ºf). the symptoms of hyperthermia include unawareness of impending hazard, failure to perceive heat, failure to recognize the need to exit the spa, physical inability to exit the spa, fetal damage in pregnant women, and unconsciousness resulting in a danger of drowning. the use of alcohol, drugs or medication can greatly increase the risk of fatal hyperthermia in spas. to reduce the risk of injury: the Consumer products safety Commission has stated that the water in the spa should never exceed 104ºf (40ºC). water temperatures between 100ºf (38ºC) and 104ºf (40ºC) are considered safe for a healthy adult. lower water temperatures are recommended for extended use (exceeding 10 minutes) and for young children. extended use can cause hyperthermia. pregnant or possibly pregnant women should limit spa water temperatures to 100ºf (38ºC). failure to do so may result in permanent injury to your baby. you should consult with a physician prior to using a spa. do not use a spa immediately after strenuous exercise. do: Measure the water temperature with an accurate thermometer before entering the spa to verify the digital thermometer since the tolerance of water temperature regulating devises may vary as much as +/- 5ºf (2ºC). test the water with your hand to be sure it’s comfortable before entering the spa. don’t: Use alcohol or drugs before or during spa use. stay well hydrated and drink plenty of water. stay in the spa for extended periods of time. If you are going to be in the spa for more than 10 minutes, you should reduce the temperature of the spa to 100ºf (40ºC) or lower. iMpoRtAnt spA instRUCtions do: Use and lock the vinyl cover when spa is not in use whether it is empty or full. Because heat retentive materials are used to insulate the spa for efficient operation, an uncovered spa surface with direct exposure to sunlight and high temperatures for long periods of time is subject to permanent damage. damage caused by exposing the spa to this abuse is not covered by the warranty. 7
  • 8. LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 8 Important Safety Instructions Follow spa care and maintenance stated in this owner’s Guide. Use only approved and recommended accessories, chemicals and cleaners. don’t: leave the spa exposed to the sun without water or the vinyl cover in place. exposure to direct sunlight can cause solar distress of the shell material. Roll or drag the spa on its side. this will damage the siding. lift or drag the cover by using the cover lock tie downs. always lift or carry the cover by using the handles. Attempt to open the spa control box. there are no user serviceable parts inside the spa control box (spa pack box) . opening of the control box by the spa owner, unless instructed by the manufacturer’s factory trained technical support technician will void the warranty. If you have an operational problem, carefully go through the steps outlined in the troubleshooting section. If you are not able to resolve the problem, please call technical support at 877-722-4097. Many problems can easily be diagnosed over the telephone by the service technician. FCC notiCe If your spa is equipped with audio or video equipment, it has been tested and found to comply with the limits for a class B digital device, pursuant to Part 15 of the fCC Rules. these limits are designed to provide reasonable protection against harmful interference in a residential installation. this equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, use harmful interference to radio communications. However, there is no guarantee that the interference will no occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment on and off, the user is encouraged to try to correct the interference by one or more of the following measures: 1. Rearrange or relocate the receiving antenna; 2. Increase the separation between equipment and receiver; 3. Connect the equipment into an outlet on a circuit different from the circuit connected. 4. Consult the dealer or an experienced radio/tV technician for help. any changes or modifications not expressed or approved by party responsible for fCC compliance could void the user’s authority to operate this equipment. 8
  • 9. LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 9 Important Safety Instructions important CsA safety instructions (Canada only) when using this electrical equipment, basic safety precautions should always be followed, including the following: 1. Read and follow all InstRuCtIons. 2. a green colored terminal or a terminal marked G, Gr, Ground, Ground- ing or the symbol * is located inside the supply terminal box or compartment. to reduce the risk of electric shock, this terminal must be connected to the grounding means provided in the electric supply service panel with continuous copper wire equivalent in size to the circuit conductors that supply this equipment. *IeC Publication 417, symbol 5019. 3. at least two lugs marked “Bonding lugs” are provided on the external surface or on the inside of the supply terminal box/compartment. to reduce the risk of electric shock, connect the local common bonding grid in the area of the hot tub to these terminals with an insulated or bare copper conductor.. 4. all field installed metal components such as rails, ladders, drains, and other similar hardware within 10 feet (3m) of the hot tub shall be bonded to equipment grounding buss with copper conductors.. 5. saVe tHese InstRuCtIons. 9
  • 10. LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 10 Location - Choosing the perfect place for your spa. it’s not only the location - but also the Foundation Proper placement of your spa is key not only to enjoying it, but also taking care of it. after all, it’s a substantial investment that you want to take care of so it will continue to bring years of enjoyment. wherever you choose to place you spa, there are some basics that must be followed. Consider the weight of the spa. you must have the proper foundation to support not only its dry weight, but also its filled weight. structural damage that occurs to your spa that results from an inadequate foundation is not covered under your warranty so it’s important that you follow the manufacturer’s guidelines. the manufacturer recommends that your laguna Bay spa be placed on a reinforced concrete pad that is at least four inches thick and large enough to accommodate the entire spa. the concrete should cure for a minimum of 72 hours before placing the spa on the pad. you should place your spa so the electronics and circuit breakers are easily accessible. and remember that the electronics must be kept dry, so drainage of water away from the spas foundation is important. the spa must not be placed in the way of landscaping sprinklers to ensure there is no damage to the skirt or frame of the spa. Inquire with local officials about building codes, electrical and plumbing codes.. think about the desired proximity to the doors of the house especially in cold weather,. Be sure there is a pathway that can be easily maintained and is free from debris. try to keep your spa away from roof overhangs and guttering to increase the life of the spa cover. when choosing the location for your spa, try to remember the effects of wind, exposure to the sun and the location of trees to minimize the effects of falling debris and shade. If you choose to place your spa on a deck, ask a licensed contractor or engineer to determine the deck’s maximum load bearing capacity. the weight per square foot must not exceed that limit or the result will be serious structural damage to the deck and the spa. If you are considering a recessed spa in your deck or floor, be sure there is access to the electrical equipment and other components in the rare case that your spa may require servicing. Make sure there is adequate room to remove all exterior panels, with special attention paid to the side where the electrical components are located. If you are placing your spa indoors or in a basement, choose a floor covering that will hold up well to the water that will inevitably sit around the spa. floor covering should be slip resistant with some ability to grip when the floor is wet. there must be adequate drainage away from the spa. the location and floor covering must be able to handle draining of the entire spa. Humidity should be considered, as should moisture to the wood, paper, drywall, and any mold and mildew which accompanies humid areas of the home. some spa chemicals may have an adverse reaction to some household metals. you should consider installing a ventilation system to address these issues. again, adequate support for the weight of the spa is vital. do: Following all procedures in the owner’s Guidebook and water care products (chemical) packaging. test the water regularly to ensure the chemical balance is correct. drain, clean, and refill your spa with fresh water regularly in accordance with the owner’s Guidebook. Clean the filters a minimum of once a month. ensure proper water circulation. Always bathe or shower before entering the spa. proper maintenance of filters, water chemistry, and ventilation reduces the risk of exposure to viruses and bacteria that may be present in the water and in the air. 10
  • 11. LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 11 Location - Choosing the perfect place for your spa. Manufacturer’s preferred site preparation the concrete pad should be 4” (7.6 cm) thick sloping 1/2” (1.3 cm) per 10 feet (305 cm) so rain and runoff will not puddle on the underside of the spa for long periods causing the frame to deteriorate. improper site preparation water “self levels”. If a spa is placed on grass, dirt, pea gravel, stones or brick, they can shift causing the spa to be out of level. It is important to remember that your warranty does not cover spas that are not properly placed on a level, well prepared foundation. How to Install Cover Locks Cover lock installation Cover Put the spa cover on the spa. Position the tie down locks on the spa cabinet so they Tie Down Straps can easily reach the tie down straps. allow Cover Lock and Key approximately 3/4 inch slack in the straps so there is ample room for the clip to slide easily into the lock 2 Screws when there are variations in the weather. attach the locks with screws. never leave the spa uncovered and unattended. never leave the spa cover unlocked. do not sit, stand or lie on the cover. 11
  • 12. LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 12 Electrical Information Avoid the Risk oF eleCtRoCUtion. lAgUnA BAy spAs ReCoMMends thAt eleCtRiCAl CoMponents Be instAlled only By A liCensed eleCtRiCiAn. All eleCtRiCAl ConneCtions MUst Be peRFoRMed By A QUAliFied liCensed eleCtRiCiAn in ACCoRdAnCe With the nAtionAl eleCtRiCAl Code (neC) And With stAte And loCAl eleCtRiCAl Codes in eFFeCt At the tiMe oF the instAllAtion. ConneCting the spA to An iMpRopeRly WiRed CiRCUit Will eliMinAte MAny oF the spA’s BUilt in sAFety FeAtURes WhiCh MAy ResUlt in FiRe, eleCtRoCUtion, oR otheR Risk oF injURy. dAMAges to the spA WhiCh ARe the ResUlt oF iMpRopeR WiRing ARe not CoveRed UndeR the MAnUFACtUReR’s WARRAnty And Will teRMinAte All listings FRoM independent listing AgenCies. the eleCtRiCAl diAgRAMs ContAined in this MAnUAl ARe inClUded As A gUideline FoR the liCensed eleCtRiCiAn instAlling the eleCtRiCAl ConneCtions. All WiRing MUst Be WAteRtight ! ! ! neveR tURn poWeR on to the spA When it is not Filled With WAteR ! Remove the spa from its packaging materials. Retain all warranty, safety and operation materials. prior to performing any service to your laguna Bay spa, turn off all primary electrical equipment at the main circuit breaker or disconnect panel. your laguna Bay spa must be permanently connected (hard wired) to the power supply. no plug in connections, extension cords or surge protectors are to be used in conjunction with the operation of your new spa. Power supplied to your laguna Bay spa must be a dedicated circuit with no other appliances, lighting, or any other electronic components powered by this circuit. there are a few laguna Bay spa models equipped with a 120V Ground fault Circuit Interrupter (GfCI) cord attached. If this is what you ordered, the power service requirement is 110 Volt 20a. this service branch is to be a dedicated 20 amp circuit, within 15 feet and not closer than 5 feet (1.5m) from the positioning of the spa equipment. no plug in connections, extension cords or surge protectors are to be used in conjunction with the operation of your new spa. Power supplied to your laguna Bay spa must be a dedicated circuit with no other appliances, lighting, or any other electronic components powered by this circuit. the electrical supply for this product must be housed in a weatherproof service box and include a suitably rated switch or Ground fault Circuit Interrupter between the main service entrance and the spa to open all ungrounded supply conductors tin compliance with section 422-20 of the national electrical Code/usa, ansI/nfPa/70 and in compliance with underwriters laboratories, Inc.. this might be used as a shut off switch, which must be installed so that it is accessible to the spa occupants, but not within 5 feet (1.5m) of the spa. All connections should be made using copper conductors only. do not use aluminum wire. Connection wires, circuit breakers, and/or fuses, must all be sized to accommodate the total ampere load. 12
  • 13. LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 13 Electrical Information to make your laguna Bay spa electrical connections, remove the entire cabinet with the sticker that says “ReMoVe tHIs Panel foR eleCtRICal”. In most models you will remove the panel underneath the spa’s top side control pad by removing all screws attaching the cabinet panel to the spa frame. At this tiMe, hAnd tighten the Unions And ensURe the sliCe vAlves ARe in the Up position. iF the sliCe vAlves ARe not in the Up position, open the sliCe vAlves And AttACh the Clip loCks With the sliCe vAlves in the Up position. RUn yoUR spA And CheCk FoR leAks BeFoRe ReinstAlling eXteRioR ACCess pAnel. this shoUld Be done eACh tiMe this pAnel is ReMoved. All eleCtRiCAl ConneCtions MUst Be MAde By A liCensed eleCtRiCiAn. do not ConneCt poWeR to the eMpty spA. poWeR to the spA AUtoMAtiCAlly ACtivAtes CRitiCAl CoMponents Within the spA, sUCh As the ContRols And the heAting. iF poWeR is sUpplied to the CoMponents pRioR to the spA Being Filled, the CoMponents Will Be dAMAged. dAMAge thAt oCCURs to the CoMponents BeCAUse poWeR WAs sUpplied BeFoRe the spA WAs Filled With WAteR is not CoveRed By the MAnUFACtUReR’s WARRAnty. 220v installation Correct wiring of the electrical service box, GfCI box and pack terminal block is required. spas installed for 220v operation require a 4-wire, 50 amp or 60 amp (depending on the spa model), 220 volt subfeed in non metallic pipe to the spa equipment compartment. a green colored terminal is Service provided in the control box. to reduce the Panel risk of electrical shock, connect this terminal GFCI Panel or connector to the grounding terminal of located your electrical service or supply panel with a at least continuous green insulated copper wire. In 5 feet (1.5m) addition, a second pressure wire connector is from spa. provided on the surface of the control box for bonding to local ground points. to reduce the risk of electrical shock, this connector should be bonded with copper wire to any reinforced concrete, metal water pipes, or any metal within 5 feet (1.5m) of the spa. International customers should contact their laguna Bay spas dealer for electrical wiring Requirements. Refer to supplied wiring diagrams and call technical support for assistance if necessary. Us and Canadian gFCi Wiring diagram the black and red wires from the electrical box must be connected to the input of the GfCI. the white wire from the electrical box must be connected to the neutral bus. the green or copper wire must be connected to the ground log of the GfCI. the black, red and white wires going to the spa must be connected directly to the output of the GfCI. the neutral to the GfCI must be connected to the neutral bus. the green or copper wire going to the spa must be connected to the ground lug. 13
  • 14. LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 14 Electrical Information important: to allow the 220V GfCI to function properly, connect the white neutral wire Spa GFCI Breaker Box Wiring Breaker Box Wiring from the spa to the neutral terminal on the GfCI breaker, not the neutral bus in 50A GFCI 50A GFCI the GfCI breaker box. an improperly To Main To Main n To To Spa To Main To Main To Spa To Spa a connected neutral causes the GfCI breaker to trip.do not replace the exterior cabinet panel until your new laguna Bay spa has been filled with N G N G water. Be sure to hand tighten the unions in the plumbing lines and ensure E E N N U U D D T the slice valves are locked in the up T position at this time. see page 17 for reference. 1. Terminal Block 1.)Remove the exterior cabinet panel 2. Bonding Lug beneath the topside controls. 3. Grounding Terminal 2.) Remove the screws from the faceplate of the spa pack. 3 3.) Choose one of the available break Exterior away conduit entry points and remove 2 Access Panel the disc from the desired location. 1 4.) Connect the conduit to the Spa Pack using a water tight connector. 5.) Feed wiring through the conduit entry points in the spa pack box. 1.) Remove enough insulation from each wire to ensure contact with TB3 screw. Failure to remove insulation will cause spa pack to malfunction. 2.) Connect the electrical service Green wires, color to color, on the terminal TB1 blocks TB1 and TB3 located in the spa pack box. Black 1 TB2 3.) Tighten SECURELY to prevent Power Neutral ^^^^^^^^^^^^^^^ damage. In Red 2 4.) Replace the spa pack faceplate with screws. To Circuit Board 14
  • 15. LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 15 Electrical Information 110 v installation all 110 volt laguna Bay spas are delivered with a GfCI power cord that is approximately 15 feet in length. electrical service must be no farther than 15 feet (4.5m) and no closer than 5 feet (1.5m) to the spa. do not connect the spa using extension cords or surge protectors. the spa must be connected to a dedicated 110v/20a GfCI protected, grounded circuit. this circuit must not be used by or shared with any other electrical component. If it is connected to a shared circuit, it will overload the circuit leading to tripping at the main breaker. failure to connect the spa to a breaker that is not dedicated may result in damage or failure of the equipment which is not covered by the manufacturer’s warranty. do not modify the plug in any way in an attempt to bypass the manufacturer’s recommendations. alteration of the plug will void the manufacturer’s warranty. the dedicated circuit must have a 20 amp GfCI in the main breaker panel with ground wire and the correct polarity throughout the circuit. a pressure wire connector is provided on the exterior surface of the control box, inside the spa. this wire allows grounding between this point and any metal equipment, reinforced concrete, metal pipe or water pipes within 5 feet (1.5m) of the spa. the bonding wire must be solid copper wire. if your electrician has questions about the wiring instructions, please call laguna Bay spas technical Assistance at (877) 722- 4097. Factory trained technical service specialists are available to answer questions during their normal business hours Monday through Friday from 8:30 am to 5 pm est. your new laguna Bay spa has been put through rigorous testing during the manufacturing process. It is not uncommon that some water may remain in the plumbing after testing and may leave spots on the acrylic finish or cabinetry. wipe the spa and cabinet with a clean soft rag. do not use houseold cleaners that contain bleach or amonia because they may have an adverse effect on the acrylic surface of the spa and have a negative reaction with chemicals used to maintain water chemistry. neVeR use aBRasIVe CleaneRs on you sPa BeCause tHey wIll CReate PeRManant sCRatHes on tHe aCRylIC suRfaCe. do not Apply poWeR to the eMpty spA. poWeR to the spA ACtivAtes CRitiCAl CoMponents Within the spA, sUCh As the ContRols And the heAting. iF poWeR is sUpplied to the CoMponents pRioR to the spA Being Filled, the CoMponents MAy Be dAMAged. dAMAge thAt oCCURs to the CoMponents BeCAUse poWeR WAs sUpplied BeFoRe the spA WAs Filled With WAteR is not CoveRed By the MAnUFACtUReR’s WARRAnty. do: Follow the instructions each time you re-fill the spa to ensure successful start up Manually turn the gFCi into the “off ” position. With the filters removed and the drain valve open, run water through the filtration canister and jet lines until the water runs clear. this will remove any incidental dust, dirt and debris that may have accumulated during shipping and installation. Rinse the inside of the spa with warm water Check for obvious signs of freight damage including loose wires or broken pipes. Check to see that the unions for the heaters and plumbing are hand tightened. 15
  • 16. LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 16 Filling Your Spa & Navigating the Hardware Check to see that the slice valves are locked in the “uP” position. do not run the spa with the slice valves in the closed or down position or with no water in the spa. this will damage the pumps and seals. damage that occurs because the spa has been operating with the slice valves in the “closed” position is not covered under the manufacturer’s warranty. Check to see that all jets, air valves, and the diverter valves are open. do not force them to turn beyond the built in stop. do not: Clean the acrylic surface with cleaners that are not approved by laguna Bay spas, especially houseold bleach and ammonia based cleaners commercially manufactured to clean glass. Use water that is filtered or from a water softener. Fill the spa with hot water. this may damage the spa controls. Use the spa until you have completed each of the steps in this section of the owner’s guidebook. Add chlorine if treating your spa with polyhexamethylene biguaride [Biguanide, PHMB, (Baquaspa®)]. leave the spa unattended while the cover and the exterior panels are not in place. Filling & Re-Filling yoUR neW lAgUnA BAy spA With WAteR when you are certain the drain valve is closed, the slice valves are locked in the up position and the unions have been hand tightened, remove the floating weir, skimmer basket and filters from the filtration Canister of your new laguna Bay spa. Place a garden hose into the empty filtration canister. water will begin filling the spa from footwell inside the spa. filling the spa in this manner will allow the pump to partially prime. allow water to continue filling the spa until the water level is approximately 4 inches over the filtration canister area of the spa. Remove the garden hose and replace the filter, skimmer basket and floating weir. Check for leaks inside the cabinet of the spa, especially at the unions for plumbing and heaters and hand tighten if necessary. Be sure slice valves are locked in the open position. iMpoRtAnt: over filling your spa will not allow room for water to displace when people enter the spa and will cause water to overflow. under filling the spa will not allow the water to flow properly through the water lines and pumps causing a potential air lock or damage to the pumps and heater. damage that occurs because of improper water levels is not covered under the manufacturer’s warranty. each time you fill your spa, it is a good idea to check the condition of the locks on the slice valves to ensure they have not become damaged. at the same time you should check to be sure that all plumbing unions are hand tightened. you should not replace the spa cabinet unitl the spa has been filled and power has been applied. the cabinet should only be replaced after you are sure all the pumps and jets are in proper working order. If you decide to replace the screws on the cabinet, they should be replaced only with stainless steel screws which will not rust. The slice valves located along the plumbing lines near the Slice Valve unions. locked in the up C During normal operation, the slice valves should position be locked in the up position. If your spa requires service, the slice valves can be closed to seal the plumbing and keep the water in the spa. If you Pump have low or no water flow, check to be sure the slice valves are locked in the up position. The Plumbing valve will not stay in the up position without the Unions lock; the force of the pump will pull the valves into the closed position if the locks are not in place. 16
  • 17. LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 17 Filling Your Spa & Navigating the Hardware Side View of Pump Skimmer S Slice Valve & Filter Housing Jet C Suction Suction Valve Footwell Valve Pump Plumbing Line In Bleeding the Pump The pumps on your new Laguna Bay Spa Flo ting We Floating We oa o Weir eir are designed to pump water, not air. If air Sk Sk immer Basket Skimmer Basket et e is in the plumbing lines when the pumps are powered on, the pumps will lock and fail to operate properly. You should Filter Filter immediately power off the pumps to avoid Housing damaging your spa. Filter Filter l Below Below located fi ter o a d filte located in filter To bleed air from the pump, open the bleed valve on the front of the pump by turning Acrylic Acrylic housing belo h u ng be ow below the valve stem in a counter clockwise Surface Surface acrylic surface acrylic r c a y c surface direction. If you use vice grips, be careful not to break the stem off the valve. Water will trickle from the valve after the all the air has been released. When water trickles Filling the Spa from the valve, turn the valve stem in a Do not put the water hose clockwise direction to tighten and close inside the acrylic when filling the spa. the Bleed Valve. Turn the skimmer basket clockwise until it stops. You should consider bleeding the air from the pumps prior to powering on the GFCI Remove the filter basket and filter housing. Put the each time you fill your spa. Making sure air water hose into the filter housing. The internal is released from the plumbing lines before plumbing lines will fill with water from the bottom they are powered on will ensure the pumps moving upward. Water will begin entering the spa operate properly and will prolong the life through the suction valves and jets into the footwell. of the spa. As the level rises, water will enter through the lowest Front of jets to the upper jets. When the water level is 4” above Front Pumpof Pump View the filter housing, remove the hose. Replace the filter and skimmer basket into the filter housing. Lock in place by turning counter clockwise until it stops. Plumbing Line Filling the spa in this manner allows the plumbing In lines to fill with water greatly reducing the risk of developing an air lock in the pumps. If water surges Bleed Valve & or if you hear a hum when the pump is turned on, Thumb Screw there is an air lock in the pump. Immediately turn the pump off to avoid damaging spa and bleed the air from the pump. 17
  • 18. Filling Your Spa & Navigating the Hardware You You can control the intensity of the water flowing o control intensity water flo from the water fall by rotating the valve loca from waterfall by rotating valve located on the topside of the spa. The water fall will help topside The waterfall create a more relaxing spa experience create more relaxing experience. Off On The waterfall is intended to create ambience and is not designed to be load bearing. It should never be used as a support or hand rail. Excessive force or weight loads may cause injury or break the waterfall assembly.
  • 19. LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 19 Filling Your Spa & Navigating the Hardware Understanding the diverter valves Customizing the force of power in the seating areas your new laguna Bay spa was designed to allow customization of your spa experience. By controlling the flow of the water through the pumps to the jets you will be able to move water from one area of the spa to another and back again. you will also be able to control the flow of the water as it is forced through the jets. the air valves, located along the acrylic surface on the top of the spa, increase and decrease the air flow as they are rotated between the “open” and “closed” positions. Increasing the air flow by opening the air valves will allow air to be forced into the spa creating “bubbles” and increase the intensity of your spa experience. decreasing the air flow by closing the air valves will provide a more relaxing spa experience. the flow can be wide open, completely closed, or anywhere you choose in between. there are built in “stops” which limit the rotation of the valve. do not force the valve past the stop point. it will break the valve and damage the spa. iMpoRtAnt inFoRMAtion ABoUt heAting yoUR spA When the heater is on, the red light on top of the heating unit will also be on. the actual water temperature will be displayed on the topside controls. the high and low water temperatures are preset by the manufacturer. the low temperature is 56ºf. the high temperature is 104ºf. setting the thermostat to a higher temperature will not cause the water to heat faster. It will only result in a higher water temperature. the heater operates until the actural water temperature is within 3ºf of thetemperature that is programmed and locked into the thermostat, then it will automatically shut off. the heater will reactivate when the water temperature drops within 3ºf below the temperature programmed and locked into the thermostat. the spa is equipped with a state of the art components. Because the spa is equipped with a highly advanced heater and is designed for maximum energey effieiency, each time you exti the spa, you should reduce the programmed temperature. during warm weather, or in very warm climates, you should lower the programmed temperature setting to just below you average forecast high temperature. for example, if your average weekly forecast high is 88ºf, you should set reduce your temperature setting to 86º or below. when you are ready to use your spa, increase the temperature to the desired setting about 30 minutes prior to use. in the 110v spa models, the pump is a single speed pump. in the 220v electrical configuration, the heater does work simultaneously with the pump on high speed. when the heating unit turns on, the pumps will only operate on low speed. Repeatedly touching the pump button to override the pre programmed settings and attempting to turn the pumps on high speed the while the spa is heating will not turn the pumps on high speed. It will instead trip the GfCI, the main breaker and has the potential to damage the spa. damage caused to the spa attempting to override the programmed settings with the pump button is not covered under the manufacturer’s warranty. getting to know the topside Controls the control pad on your spa will vary depending on the model you purchased. your laguna Bay spa was created to be one of the most user friendly spas available in the marketplace. until now, most spa controls offered some choices but they forced users into an either/or choice. the settings limited use and conserving energy made some spa functions non existent. laguna Bay spas are manufactured so you can use your spa the way you want to, when you want to. since each button controls one thing, and only one thing, you can choose what the spa does and when it does it simply by pressing the correct button. once the spa is filled, the electrician has installed the GfCI from your main power supply and has connected the wires to the spa pack, reattach the panel door on the spa pack. don’ reattach the cabinet panel just yet. turn GfCI into the “on” or “Reset” position. the instructions for your topside controls will vary depending upon which laguna Bay spa you purchased. Please refer to the set of instructions matching the topside controls on your spa. 19
  • 20. LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 20 Water Chemistry It is imperative to have clean, clear, water. water maintenance will vary depending on many things such as quality of your water, how frequently you use your spa, and how many people use the spa. the fundamental things to consider when it comes to maintaining the water in your spa are filtration, sanitation, and proper balance of chemicals and pH. following a regular schedule will help you achieve acceptable water sanitation along with proper levels of total alkalinity and Calcium hardness. It is important to remember that bacteria and viruses grow quickly in water that is not properly maintained. It is your responsibility to keep your water in proper balance to not only for proper sanitation, but also for minimal buildup of deposits and to prolong the life of the spa. Basic Chemical safety when using chemicals, read the labels and follow the directions. Chemicals are designed to protect you and your spa they can be hazardous if not handled correctly. do: Wait until the water temperature has reached a minimum of 80ºf before adding chemicals Wash your hands after handling chemicals. In case of accidental contact, follow the emergency advice on the product label. keep chemicals in their original container. Allow a responsible person to handle spa chemicals. keep chemicals away from children and pets. ALKALINE 8.2 ADD pH SPA DECREASER handle all containers with care. store chemicals in a cool, dry, well ventilated place. WATER 7.8 TO LOWER (MAY CAUSE pH keep chemical containers closed when not in use. SCALING) 7.6 prooperly Replace caps on their containers. if a doctor is needed, take chemical containers with COMFORT IDEAL ZONE 7.4 you to the hospital so the substances can be identified. don’t: Add chemicals to water temperatures below 80ºf ACIDIC 7.2 ADD pH store chemicals in the spa cabinet. SPA INCREASER Use a vacuum cleaner to clean up chemical spills. WATER 6.8 TO Allow anyone in the spa while adding chemicals. (MAY CAUSE RAISE pH inhale fumes or allow chemicals to come in contact CORROSION) pH with your eyes, nose or mouth. Use chlorine tablets (trichlor) in your spa. It can be extremely corrosive. damage caused by use of tri- chlor is not covered under the manufacturer’s warranty. store Chemicals in extreme temperatures or bright light. let chemicals get on surrounding surfaces or landscaping. sMoke ARoUnd CheMiCAls. some fumes are highly flammable. Use swimming pool chemicals, muratic acid or household bleach in your spa. Manufacturer recommended replacement chemicals can be ordered from laguna Bay spas. to place an order visit lagunaBayspas.com and click on the link for “spa supplies” All spA CheMiCAls MUst Be Added diReCtly into the FilteR CoMpARtMent While the pRiMARy pUMp is RUnning FoR A MiniMUM oF ten MinUtes With the CoveR oFF the spA. do not leAve the spA UnAttended While the spA is UnCoveRed. one of the biggest reasons service is needed on spas is because the water chemistry is not balanced. too many chemicals will cause deterioration of many of the components in the spa. water can accumulate impurities that can impair the performance or even damage the filtration system if chemical balance is not maintained. water can become unhealthy if chemicals are not used to sanitize water. Improper pH or calcium levels can lead to corrosion and scale build up on integral spa components. 20
  • 21. LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 21 Water Chemistry the following guidelines have been established by the association of Pool and spa Professionals: pH 7.4 to 7.6 Free Chlorine 3.0 to 4.0 ppm Free Bromine 2.0 to 4.0 ppm Total Alkalinity 100 to 120 ppm Calcium Hardness 150 to 250 ppm Adding Chemicals to Water it is important to add chemicals only after the water temperature has reached 80ºF to prevent damage to the acrylic surface. fold back the cover. never leave the spa unattended while the spa cover is not in place. Remove the filter basket assembly (see page 17 for instructions). Press the Primary Pump button twice to turn the pump on high. Carefully measure the recommended amount of chemical in accordance with the instructions on the label. add chemicals through the filtration canister with the primary pump on high speed, allowing water to circulate for a minimum of ten minutes with the spa cover off. never leave the spa unattended when the cover is off. use care not to splash chemicals onto your hands, into your eyes, onto the spa cabinet, or on the acrylic surface of the spa. Replace the lid onto the chemical container. after ten minutes, reduce the primary pump speed to low and close and lock the cover. WARning: high levels oF sAnitiZeR CAn CAUse disCoMFoRt to eyes, lUngs And skin. AlWAys AlloW sAnitiZeR levels to FAll to the ReCoMMended levels BeFoRe Using the spA. each step in this water maintenance program is dependent of the previous steps. omission of a step, or failing to reach the recommended range may cause an imbalance in water chemistry. Unbalanced water may lead to damage to the spa and its components and discomfort for spa users. damage to the spa caused by improper water chemistry is not covered under the manufacturer’s warranty. to measure the quality of your spa’s water, immerse the test strip in water, following the instructions on the test strip. do not touCH tHe test stRIP wItH youR fInGeRs as It May affeCt tHe outCoMe of tHe test Result. Compare the test strip and the label to determine the condition of the spa water. step 1.) Balancing total Alkalinity (tA) the recommended total alkalinity for your spa is between 125 and 150 ppm. the total alkalinity is a measure of the total levels of carbonates, bicarbonates, hydroxides and other alkaline substances in the water. ta is referred to as the water’s “pH buffer”. It is a measure ot the water’s ability to resist changes in the pH level. If the ta is too low, the pH level will fluctuate from high to low. fluctuations in pH can cause corrosion or scaling of the spa components. low total Alkalinity can be corrected by adding sodium hydrogen carbonate (ph/Alkalinity Up). step 2.) Balancing Calcium hardness (Ch) the recommended calcium hardness (CH) level for your spa is 150-200 ppm. Calcium Hardness is a measurement of the total amount of dissolved calcium in the water. Calcium helps control the corrosive nature of the spa’s water. Calcium-low water (commonly known as “soft” water) is not recommended. It is hightly corrosive to the spa and the spa components and can cause staining of the spa shell. If the CH is too high (commonly known as “hard”water),formation of scale on the spa and the spa components can result. Ch can be decreased by dilution - a mixture of 75% “hard” water and 25% “soft” water will usually yield a reading of the correct range. If “soft” water is not available or practical for you, a stain and scale inhibitor should be added to the water, according to the label instructions. If CH is too low, add a CH increaser. once the CH is balanced, it normally remains stable. adding more water with a low or high calcium content will raise or lower the CH reading of the water. when the Calcium Hardness is within recommended range, proceed to the next step. 21
  • 22. LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 22 Water Chemistry step 3.) Balancing the ph It is imperative to have a slightily alkaline pH level for your spa water between 7.4 - 7.6. Problems become proportionately severe the further outside the range the water gets. the pH level is the measure of the acidity and the alkalinity. Values above 7 are alkaline; those below 7 are acidic. Maintaining proper pH level is extremely important for optimizing the effectiveness of sanitizer, maintaining water the is comfortable for the user, and preventing equipment deterioration. If the spa water’s pH level is too low, the sanitizer will dissipate rapidly, the water may become irritating to users, and the spa’s equipment may corrode. if the ph is too low, it can be increased by adding sodium hydrogen carbonate (ph/Alkalinity Up to the spa water. If the pH level is too high, the sanitizer is less effective, scale may form on the spa and the spa components, the water may become cloudy and filter cartridge pores will become clogged and obstructed. if the ph is too high, it can be decreased by adding sodium bisulfate (ph/Alkalinity down) to the spa water. after adding sodium hydrogen carbonate or sodium bisulfate, WAit tWo hoURs before testing the water’s pH levels again. Measurements taken too soon may not be accurate. It is important to check the pH level on a weekly basis. the pH will be affected by the bather load, the addition of new water, the addition of chemicals and the type of sanitizer used. when the pH is within the recommended range, proceed to the final step. step 4.) Maintaining the sanitizer levels sanitizer is extremely important for killing algae, bacteria and viruses and preventing unwanted organisms from growing in the spa. at the same time, you don’t want too high a sanitizer level since it may cause irritation to the skin, lungs and eyes. always maintain the sanitizer level in your spa at the recommended level for each type of sanitizer. to keep sanitizer levels in the desired range you should check the bromine, shock, and pH levels level before each use and no less than twice each week even if the spa is not in use. do not use tri-chlor chlorine, bromo-chlor-dimethyl-hydantoin (BCdMh) or any type of compressed bromine or chlorine, acid or any sanitizer not recommended by laguna Bay spas. heavy Cleaning or decontamination on occasion, it may be necessary to “super sanitize” your spa. If algae develops, simply draining and refilling the spa will not kill the algae. It will be necessary for you to decontaminate the spa before it is refilled. during the decontamination process, excessive chemical vapors are produced. Keep children and pets away from the spa. wear gloves and a protective mask during the decontamination process. Remove the spa cover, all pillows from the spa and protect the plastic valves. If your spa is indoors, open the windows and doors. use a fan to circulate the air and force the vapors out of the room. Remove the filter basket assembly and filter (see page 17 for instructions). Before adding chemicals, make sure all pumps are operable. Check to be sure all jets and air valves are open. Be certain the diverter valves are in the center position allowing even circulation through all sections of the spa. with all pumps on low speed, add 2.5 ounces of sodium dichlor for every 100 gallons of water in the spa. for example, if there are 400 gallons of water in your spa, add 10 ounces of sodium dichlor. after all the sodium di-Chlor has been added turn all pumps on their highest speed and allow the water to circulate for one hour. do not replace the cover over the spa during decontamination. never leave the spa unattended while it is uncovered. after allowing the spa to run for one hour, press the safety start button and turn off the spa. turn the GfCI off and drain the spa. follow the procedure to refill the spa (instructions begin on page 16) and begin add chemicals as needed for proper water chemistry. a new filter should be used each time you drain and refill your spa. 22
  • 23. LagunaBayManualVer12.10.2_Layout 1 12/10/10 12:44 PM Page 23 Water Chemistry Common sense Water Chemistry Chemicals are added to your water for your safety. without chemicals, the warm water in your spa is the perfect environment for germs, bacteria and other living organisms. Chemicals added to your spa water are utilized as they destroy the bacteria from dead skin cells, sweat and other body fluids. Consistent addition of sanitizers kept at constant levels keep your water clear and safe to use. the water in your laguna Bay spa and your filter should be replaced every 3 months. what is required to maintain proper water chemistry is different in every spa and for every spa user. your water chemistry changes constantly requiring you make to adjustments. when it’s warm outside, chemicals evaporate faster than when the weather is cold. using the spa once a day will require more chemicals than using the spa once a week. what it takes to balance your water chemistry in January will be different than what it takes in July. the major considerations in water chemistry are: the number of gallons of water in the spa the number of people using the spa the number of hours the spa is being used In short, more water used by more people for more hours means more chemicals. whether you use the spa or not, you should test your water twice a week. Regularly testing water allows you to make adjustments before levels are out of control. when it comes to chemicals, more is not better. adding chemicals changes the pH, changes in the pH changes the way the chemicals react. the addition of too many chemicals makes the problem worse making your only option to drain the spa and start over. When adding chemicals, always read and follow the instructions on the label. Always verify that before use that additives will not have an adverse effect. never change sanitizers without first draining the spa. afteR addInG sHoCK to youR sPa, leaVe tHe CoVeR oPen foR a MInIMuM of 20 MInutes to allow tHe oXIdIZeR Gas to Vent. never leave the spa unattended while it is uncovered. ozone generators your spa may have come with an optional ozonator which will do a good job at killing bacteria and oxygenating water, but it will not sanitize the water. you must use bromine in tandem with the ozone generator. the ozone generator is designed to make chemicals more efficient and water chemistry maintenance easier. ozone is a gas that oxidizes contaminants and disinfects bacteria. the ozone generator injects ozone while the water is in the plumbing before it comes through the jets and into the spa. Chlorine generators your spa may have come with an optional salt system, also known as a chlorine generator. this system is designed to maintain water chemistry by converting salt into the sanitizer without the use of bromine and shock. since the system does not create any residual chlorine, water testing will not provide an accurate assessment of sanitation levels. test strips should be used to maintain adequate levels of alkalinity, pH and water hardness. 23