1. JOB REFERENCE
ALLOW FOR NEW 100mm UPVC PIPES
CONNECTED INTO ALL NEW SANITARYWARE
INTO NEW STUB STACK WITH AIR ADMITANCE
VALVE. ALLOW FOR NEW EXTERNAL BELOW
GROUND DRAINAGE TO EXISTING MANHOLE.
(SUBJECT TO SITE INSPECTION)
ALLOW TO REPLACE
EXISTING GLAZING WITH
NEW OBSCURE
FOR TOILET DETAILS REFER
GLAZING.
TO DWG 012.
ALLOW
TO FORM
NEW
WALLS IN
STUDWORK
AS
SHOWN.
ALLOW TO
FORM NEW
OPENING
ALLOW TO FORM NEW
THROUGH,
STUDWORK WALLS AS
MAKE
SHOWN, SKIMMED PLASTER
GOOD FOR
FINISH.
NEW DOOR.
GENTS
ALLOW TO FORM
NEW OPENING
THROUGH, MAKE
GOOD FOR NEW
DOOR.
REMOVE DOOR
AND BLOCK UP
EXISTING OPENING,
PREPARE TO
RECEIVE NEW DECS
REMOVE DOOR
AND BLOCK UP
EXISTING OPENING,
PREPARE TO
RECEIVE NEW DECS
AREA 5
ALLOW TO STRIP
OUT ALL
REDUNDANT
SANITARYWARE
AND CAP OFF
REDUNDANT
SERVICES.
NEW SCREEN,
REFER TO DWG 010.
AREA 4
NEW PLINTH, REFER
TO DWG 010.
ALLOW TO
REMOVE EXISTING
SCREENS & MAKE
GOOD.
NEW PLINTHS, REFER
TO DWG 010.
ALLOW TO FORM
NEW STUDWORK
WALLS AS SHOWN,
SKIMMED PLASTER
FINISH.
PART H-DRAINAGE
EXTRACT FAN WITH PLASTIC DUCTING AS REQUIRED TO TOILETS.
WASHBASIN
ALLOW TO
REMOVE
EXISTING
SCREEN AND
MAKE GOOD.
3 AIR CHANGES PER HOUR.
SINK
50mm DIA 4M MAX RUN
BATH
50mm DIA 4M MAX RUN
TRADING AREA:MECHANICAL ENGINEER TO ADVISE UPON
PROVISION AND CAPACITY OF EXTRACT FANS.
SHOWER
EXISTING FIRE ESCAPE
RETAINED, ALLOW TO
REPLACE EXISTING
DOORS.
HOOD FOR COOKER AND VENTILATION FANS.
URINALS
MANAGERS BATHROOM:ELECTRICAL CONTRACTOR TO SUPPLY
PIPEWORK TO BE IN UPVC TO BS 4514.WASTE RUNS TO BE
AND FIX EXTRACT FAN ,AND PLASTIC DUCTING AS REQUIRED
CONNECTED TO 100mm DIA SOIL AND VENT STACK EXTENDED
FAN TO BE PULL CORD OPERATED AND TO EXTRACTAT A RATE
UP MIN 900mm ABOVE ANY OPENING WITHIN 3M AND FINISHED
OF 15 LITRES/SECOND.
NEW SCREEN, REFER
TO DWG 010.
ALLOW TO BUILD NEW
RECLAIMED BRICKWORK
WALLS AS SHOWN.
ENTRANCE
ALLOW TO DEMOLISH
SECTIONS OF EXISTING
COLUMNS AS SHOWN
AND MAKE GOOD.
AREA 8
NEW SCREEN,
REFER TO DWG
010.
ALLOW TO
REMOVE
EXISTING
SCREEN AND
MAKE GOOD.
ALLOW TO REMOVE
EXISTING NIB AND
MAKE GOOD.
FOR INTEGRITY ,IN PARTICULAR THE DOOR CLOSER AND
INTUMESCENT STRIP.
ALL APPLIANCES TO HAVE MIN 75mm DEEP SEAL TRAPS.
FAN TO BE CORD OPERATED AND TO EXTRACT AT A RATE OF
APPLIANCE WASTES TO BE TAKEN TO A TRAPPED GULLY IN
PART H-DRAINAGE
NEW WINDOWS TO MANAGERS FLAT TO HAVE TRICKLE
NEW DRAINAGE IN GROUND TO BE VITREOUS CLAY PIPEWORK
VENTILATOR FREE AREA MIN 4000mmSQ.
ALLOW TO FIT
SOLID ASH SHELF
TO REAR GAP
BEHIND FIXED
SEATING.
BAR TO OPEN" NOTICE
N6
H
SMOKE DETECTOR
E
THREE HOUR NON-MAINTAINED EMERGENCY LIGHT FITTING.
"FIRE DOOR KEEP SHUT"NOTICE
CONSTRUCT NEW
FEATURE LOG STORE IN
STUD FRAME AND
PLASTERBOARD CLAD
WALLS TO RECEIVE
SKIM AND DECS.
SINGLE HEIGHT BRICK
PLINTH AND 250mm
DEEP PB CLAD SOFFIT.
HEAT DETECTOR
IP
N1
N5
WHERE PIPE PASSES THROUGH WALL OR FOUNDATION FORM
OPENING THROUGH AND LINTEL OVER.PIPE TO HAVE MIN 50mm
FIRE ALARM INDICATOR PANEL
GENERAL FIRE NOTICE(FIRE
EVENT PROCEDURES)
CLEAR SPACE AROUND.MASK EACH SIDE OF OPENING WITH RIGID
NEW GLAZING TO WINDOWS TO BE 6mm TOUGHENED SAFETY
SHEETING AS RODENT BARRIER.
PIPE RUN IN OPEN GROUND TO HAVE MIN 150mm PEA GRAVEL
BED AND SURROUND.
PARTICULAR DETAILS TO HANDRAILS AND TACTILE
MANHOLES CONSTRUCTED OF 215mm SEMI-ENGINEERING
BRICKWORK TO BS 3921,BUILT OFF 150mm CONCRETE SLAB
WITH CONCRETE FLAUNCHING TO PIPEWORK.
INTERNAL PIPEWORK TO HAVE DOUBLE SEAL COVER WITH
DISABLED TOILET TO DIMENSIONS SHOWN BELOW.
Gateway, Eastleigh
"FINAL FIRE EXIT"
"EXIT"
9 LITRE WATER EXTINGUISHER
"FIRE EXIT"
DRAWING TITLE
"EXIT,LEFT"
AFFF FOAM EXTINGUISHER
"FIRE EXIT,LEFT"
"EXIT,RIGHT"
B
2
1m FIRE BLANKET
"FIRE EXIT,RIGHT"
NEOPRENE GASKET.COVER TO BE RECESSED TO ACCEPT FLOOR
ILLUMINATED 3 HOUR MAINTAINED
TIMBER STUD PARTITION-30 MINUTES
NEW PARTITION OF 89x38mm SW HEAD AND SOLE PLATES
NOGGINS @ 1200mm c/c.FACE EACH SIDE WITH ONE LAYER
WET CHEMICAL
12.5mm GYPROC WALLBOARD PLASTERBOARD,JOINTS TO BE TAPED
TO BS 5499 PART 1 (THE GREEN MOVING
CEILING
CONTRACTOR TO DEMOLISH EXISTING STRUCTURE AS INDICATED
WHERE DOWNLIGHTERS ARE TO BE USED.
AND FOR TEMPORARY SUPPORT OF STRUCTURE AS REQUIRED BY
ALLOW FOR AT LEAST 130-140mm DROP.
FINISH WITH SKIM PLASTER TO RECEIVE DECORATION.
PERSON),EUROPEAN DIRECTIVE.
ACHIEVES HALF HOUR FIRE RESISTANCE.
WHERE RUN OF STUD PARTITION IS PARALLEL WITH JOIST
STRUCTURAL ENGINEER.CART AWAY DEBRIS AND MAKE GOOD TO
AFFECTED SURFACES.
SCALE
1:50
SHEET
A1
RUN ON TIMBER FLOOR EXPOSE FLOOR AND DOUBLE UP
ALLOW FOR A SACRIFICIAL CEILING TO ALL AREAS OF CEILING
BY BROKEN LINE.ALLOW FOR PROTECTION OF REMAINING FABRIC,
Proposed Builders Work
WITH 89x38mm SW STUDS @ 600mm c/c AND 89x38mm SW
w c
EMERGENCY EXIT SIGN.LEGENDS TO BE
DEMOLITION
Whitbread Plc.
4.5kg DRY POWDER EXTINGUISHER
NEW MANHOLES TO MIN INTERNAL SIZE OF 1200x750mm WITH
MIN 600x600mm COVER.EXACT SIZE AS DRAWING.
CLIENT
CARBON DIOXIDE FIRE EXTINGUISHER
"FINAL EXIT"
FOUNDATION UNDERSIDE.
ADS DESIGN & BRAND DEVELOPMENT
King John's Gallery, Mythe Road, Tewkesbury, GL20 6EB
Tel: +44 (0) 1684 851299 Fax: +44 (0) 1684 851298
email: info@ads-design.co.uk
PROJECT
SERVICEABILITY
PIPE WITH 150mm CONCRETE BED AND SURROUND TO LEVEL OF
KJA
"FIRE DOORS KEEP CLEAR" NOTICE
BE CHECKED AND CERTIFIED (QUALIFIED ELECTRICIAN) FOR
REF TO DOOR SCHEDULE FOR FULL DETAILS
SHEET OF TOUGHENED GLASS.
11/7/07
ALLOW TO INFILL GAP WITH SW
FRAMEWORK CLAD IN
PLASTERBOARD SKIMMED AND
PAINTED FINISH TO MATCH
ELSEWHERE.
BREAK GLASS FIRE ALARM CALL POINT.
GLASS TO BS6206 1981, TO A MINIMUM HEIGHT OF 1500mm
GLAZED SCREENS WITH LEADED GLASS TO BE BACKED WITH
DISABLED WC LAYOUT REVISED, NEW
WINDOW IN AREA 5 OMITTED, EXISTING
RETAINED WITH WORKS, SCREEN IN AREA 13
REVISED TO INCORPORATE EXISTING
SERVICES DUCT, DOOR INTO FIRE EXIT
STAIRS BLOCKED UP, REVISIONS TO GENTS
WC.
ADSDESIGN
ALL EXISTING EMERGENCY LIGHTING WHICH IS REMAINING TO
WHERE PIPE RUNS WITHIN 1M OF BUILDING FOUNDATION,ENCASE
KJA
LOBBY
PANIC BOLT EMERGENCY DOOR IRONMONGERY,WITH"PUSH
NEW GLAZING TO DOORS TO BE OF 6mm TOUGHENED SAFETY
GLASS AS BEFORE TO MIN HEIGHT OF 800mm
13/7/07
VISION PANEL TO DOOR OF 6mm GEORGIAN WIRED POLISHED
OF 100mm DIA LAID TO FALL 1:80 (UNLESS OTHERWISE NOTED
PIPE WORK IN FLOOR TO HAVE MIN 150mm CONCRETE BED AND
LOG STORE ADDED TO LOBBY. SCREENS IN
AREAS 12,4 & 9 AMENDED.
A
BELOW GROUND
ON DRAWING).CLAY PIPES TO BS 85
KJA
INTERIORS ARCHITECTURE
VP
TRICKLE VENTILATOR FREE AREA MIN 4000mmSQ.
FANS,TOGETHER WITH LINTELS,DPCS AND CAVITY TRAY.
19/7/07
PLATE GLASS,OR PILKINGTON "PYRAN" FIRE RESISTANT
S
FLOOR /GROUND, TO BE FITTED WITH A SEALING PLATE.
AMENDMENT TO FIXED SEATING BY MAIN
ENTRANCE.
B
NEW PLINTH,
REFER TO DWG
010.
GLASS,SET IN INTUMESCENT PUTTY WITH HARDWOOD BEADS.
VALVE TO A BBA CERTIFICATE.
MINIMUM DIMENSIONS OF LOBBIES AND RAMPS AND OF
C
AND DETECTORS SUBJECT TO FIRE OFFICERS REPORT.
AND FIX EXTRACT FAN AND PLASTIC DUCTING AS REQUIRED.
REFER TO DRAWINGS FOR PROVISION OF ACCESS INCLUDING
RETAIN EXISTING SERVICE
DUCT AND STUDWORK.
NEW PLINTH, REFER
TO DWG 010.
ALL EXISTING FD30S,AND FD60S FIRE DOORS TO BE CHECKED
PB
LIVING ROOM
ALLOW TO REMOVE
EXISTING SCREENS AND
MAKE GOOD TO WALLS &
FLOOR.
NOTE THAT THE EXACT LOCATION OF EMERGENCY LIGHTING
MANAGERS KITCHEN:ELECTRICAL CONTRACTOR TO SUPPLY
PART M-DISABLED
ALLOW TO STRIP OUT ALL
EXISTING RAISED LEVEL
AND MAKE GOOD TO
AFFECTED AREAS. ALLOW
TO MAKE GOOD FLOOR
READY TO RECEIVE NEW
FLOOR FINISH.
UPON COMPLETION OF TREATMENT.
50mm DIA 4M MAX RUN
100mmSTUB STACKS TO BE FITTED WITH AN AIR ADMITTANCE
PART N-GLAZING
NEW SCREEN, REFER
TO DWG 010.
STANDARD.CONTRACTOR TO SUPPLY FIRE TEST CERTIFICATE
WITH BALLOON GRATE.
MAIN CONTRACTOR TO FORM OPENINGS INWALLS/ROOFS FOR
KITCHEN
WITH PROPRIETRY TREATMENT TO A BBA CERTIFICATE
DOOR KEEP SHUT" NOTICE BOTH SIDES AT EYE LEVEL.
50mm DIA 4M MAX RUN
KITCHEN
LOBBY
UPHOLSTERY ETC) TO BE UPGRADED TO CLASS"1" STANDARD
IF PLANTED).POSITIVE OVERHEAD DOOR CLOSER."FIRE
GLASSWASH
NEW CABINETRY
REFER DRAWING No11
CLASS "0".CLASS "3" ITEMS(EG CURTAINS,DRAPES,TIMBER,
AT 300mm CENTRES MAX WITH COUNTER SUNK SCREWS
WASHMACHINE 50mm DIA 4M MAX RUN
3. The contractor is responsible for ensuring that all works comply with Local Authority
requirements and national regulations.
SURFACE SPREAD OF FLAME:WALLS AND CEILINGS TO BE
FRAME /LINING TO HAVE MINIMUM 38x15mm STOPS(FIXED
50mm DIA 4M MAX RUN
2. This drawing should be read in conjunction with relevant specifications and documentation
issued by ADS Design or third parties. the contractor is responsible for assimilating the
information and reporting descrepancies to ADS Design prior to commencement of works.
NEW PLINTH, REFER
TO DWG 010.
NEW PLINTHS, REFER
TO DWG 010.
ALLOW TO REPLACE
EXISTING GLAZING WITH
NEW OPAQUE GLAZING
TO DESIGNERS
APPROVAL.
INTUMESCENT STRIPS AND COLD SMOKE SEAL BRUSHES.
KITCHEN:CATERING CONTRACTOR TO ADVISE UPON EXTRACTION
60 LITRES/SECOND.MAIN CONTRACTOR TO SUPPLY AND FIX
NEW SCREEN,
REFER TO DWG
010.
FIRE DOOR TO HALF HOUR FIRE RESISTANCE WITH
FD30S
40mm DIA 3M MAX RUN
ALLOW TO FORM NEW
STUDWORK NIB FOR NEW PLINTHS,
REFER TO DWG 010 FOR DETAILS.
NEW SCREENS, REFER
TO DWG 010.
AREA 9
PART B-FIRE NOTES
PLUMBING SIZES:
FAN TO BE SWITCHED TO TOILET LIGHTS AND TO ACHIEVE
ALLOW TO
REMOVE
EXISTING
SCREEN AND
MAKE GOOD.
ALLOW TO
REMOVE
EXISTING
SCREEN AND
MAKE GOOD.
ALLOW TO FORM
NEW STUD WALL AS
SHOWN, SKIMMED
PLASTER FINISH.
ALLOW FOR NEW
DOORWAY.
ALLOW TO
CAREFULLY DEMOLISH
EXISTING WALL AS
SHOWN AND MAKE
GOOD.
AREA 1
NEW PLINTH, REFER
TO DWG 010.
NEW SOLID STUD
WALL PREPARED TO
RECEIVE NEW DECS
ABOVE GROUND
NEW
SCREEN,
REFER TO
DWG 010.
1. Do not scale from this drawing. All dimensions should be checked on site prior to
commencement of work or associated manufacturing.
ALLOW TO REMOVE
EXISTING DOOR &
FRAME AND MAKE
GOOD.
ALLOW TO FORM
NEW STUDWORK
WALLS AS SHOWN,
SKIMMED PLASTER
FINISH.
ALLOW TO FORM NEW
STUDWORK WALLS AS
SHOWN, WITH SKIMMED
PLASTER FINISH.
ALLOW TO
FORM NEW
COLUMN FROM
BRADSTONE.
ALLOW TO REMOVE
EXISTING SCREEN AND
MAKE GOOD.
PURPLE ROOM
TOILETS:ELECTRICAL CONTRACTOR TO SUPPLY AND FIX
AREA 7
ALLOW TO
FORM NEW
COLUMN FROM
BRADSTONE.
NEW SCREENS,
REFER TO DWG
010.
ALLOW TO FORM NEW
STUDWORK WALLS AS
SHOWN WITH SKIMMED
PLASTER FINISH.
NEW SCREEN REFER TO
DWG 010. ALLOW TO
FORM 2NO. NEW
STUDWORK PIERS AS
SHOWN.
Copyright of this drawing is owned soley by ADS Design & Brand Development Ltd.This
document is confidential and as such its contents should be treated with the utmost care
and consideration, and in no circumstances should it be disclosed, distributed, published or
copied whether in part or in whole, without the prior consent of ADS Design and Brand
Development Ltd in writing.
NEW SCREEN,
REFER TO DWG
010.
AREA 10
PART F-VENTILATION
ALLOW TO INFILL GAP WITH
STUDWORK, SKIMMED
PLASTER FINISH.
NEW SCREEN,
REFER TO DWG
010.
ALLOW TO CAREFULLY
DEMOLISH EXISTING WALLS
AS SHOWN, MAKE GOOD
TO AFFECTED AREAS.
NEW SCREENS,
REFER TO DWG
010.
ALLOW TO CAREFULLY
REMOVE EXISTING
COLUMN AND MAKE
GOOD.
AREA 2
ALLOW TO FORM NEW STUDWORK
NIB FOR NEW SCREEN & PLINTH, REFER
TO DWG 010 FOR DETAILS.
NEW SCREEN,
REFER TO DWG
010.
APPROXIMATE
POSITION OF NEW
WHB, ALLOW FOR
CONNECTION INTO
DRAINAGE RUN.
ALLOW TO REMOVE ALL
EXISTING BAR SERVERY
AND MAKE GOOD TO
AFFECTED AREAS.
NEW SCREEN AND
DRINKSHELF,
ALLOW TO
REFER TO DWG
REMOVE
010.
EXISTING
SCREEN AND
MAKE GOOD.
NEW FIREPLACE,
REFER TO DWG
013.
ALLOW TO REMOVE
EXISTING SCREEN &
MAKE GOOD.
NEW PLINTH,
REFER TO DWG
010.
ALLOW TO FORM
NEW COLUMN
FROM BRADSTONE,
TO ENCLOSE NEW
STRUCTURAL STEEL
ALLOW TO
CAREFULLY
DEMOLISH EXISTING
WALL AS SHOWN
REMOVE DOOR &
FRAME, MAKE
GOOD TO
AFFECTED AREAS.
BLUE ROOM
AREA 11
NEW SCREEN,
REFER TO DWG
010.
ALLOW TO REMOVE ALL
EXISTING BAR SERVERY
AND MAKE GOOD TO
AFFECTED AREAS.
BAR SERVERY
ALLOW TO
REMOVE
EXISTING
SCREEN AND
MAKE GOOD.
NEW ATM
ENCLOSURE REFER
DRAWING No 11
AREA 6
NEW WALLS TO
COMPLETELY
ENCLOSE NEW
STRUCTURAL STEEL
COLUMNS AS PER
ENGINEERS SPEC
ALLOW TO CAREFULLY REMOVE EXISTING
COLUMN AND MAKE GOOD.
NEW BAR SERVERY AND
BACKFITTING, REFER TO
DWGS 07 & 08.
BAR
AREA 6
NEW SCREEN, REFER
TO DWG 010.
ALLOW TO DEMOLISH
EXISTING SCREEN & WALLS
AND MAKE GOOD. REROUT
EXISTING SEVICES INTO NEW
STUD WALL
ALLOW TO
CAREFULLY DEMOLISH
EXISTING WALLS AS
SHOWN AND MAKE
GOOD.
ALLOW TO DEMOLISH
EXISTING WALLS AS
SHOWN & MAKE GOOD.
ALLOW TO STRIP OUT ALL
REDUNDANT
SANITARYWARE AND CAP
OFF REDUNDANT SERVICES.
ALLOW TO DEMOLISH EXISTING WALLS
AND SERVICE DUCT AS SHOWN.
ALLOW TO RE-ROUTE SERVICES.
AREA 12
RED ROOM
ALLOW TO REMOVE ALL EXISTING
BAR SERVERY AND MAKE GOOD
TO AFFECTED AREAS.
ALLOW TO FORM
2NO NEW
RECLAIMED
BRICKWORK PIERS
AS SHOWN.
AREA 13
ALLOW TO STRIP
OUT EXISTING
BATHROOM AND
CAP OFF EXISTING
SERVICES,
CAREFULLY
DEMOLISH EXISTING
WALLS AS SHOWN
AND MAKE GOOD.
BAR
ALLOW TO REMOVE
EXISTING SCREENS &
MAKE GOOD.
NEW SCREEN,
REFER TO DWG 010.
ALLOW TO INFILL REDUNDANT DOORWAY
WITH STUDWORK, SKIMMED PLASTER FINISH.
NEW STUD WALLS TO
COMPLETELY
ENCLOSE NEW
STRUCTURAL STEEL
COLUMNS AS PER
ALLOW TO FORM
ENGINEERS SPEC
NEW WALL FROM
BRADSTONE
STONEWORK.
NEW POSEUR
DINING SHELF, REFER
TO DWG 011.
ALLOW TO
DEMOLISH EXISTING
WALLS AS SHOWN &
MAKE GOOD.
NEW STUDWORK WALLS AS
SHOWN, SKIMMED PLASTER
FINISH.
ALLOW TO FORM
NEW STUDWORK
COLUMN AS
SHOWN, SKIMMED
PLASTER FINISH.
ALLOW TO FORM
NEW WALLS IN
STUDWORK AS
SHOWN.
AREA 4
ALLOW TO REMOVE
EXISTING DOOR &
FRAME AND MAKE
GOOD
ALLOW TO INFILL
REDUNDANT
DOORWAY WITH
NEW STUDWORK,
SKIMMED PLASTER
FINISH.
BROWN ROOM
NEW SCREENS,
REFER TO DWG 010.
LADIES
DISABLED
WC
ALLOW TO STRIP OUT ALL
REDUNDANT
SANITARYWARE AND CAP
OFF REDUNDANT SERVICES.
FOR TOILET DETAILS
REFER TO DWG 012.
NEW DRAINAGE AS
PER NOTE ABOVE.
07041
RETAIN EXISTING WINDOW, REGLAZE
WITH BLACK GLASS. BLOCK UP
INTERNALLY WITH STUD FRAME AND
PB CLADDING. SKIM ENTIRE WALL IN
PREP FOR NEW DECS
FIRE PROTECTION-STEELWORK
PROTECT STEELWORK WITH ONE
LAYER OF GYPROC 12.5MM FIRELINE
PLASTERBOARD FIXED TO GYPROC
Gyplyner "ENCASE" STEEL CLIP
SYSTEM FIXED IN ACCORDANCE WITH
MANUFACTURER'S INSTRUCTIONS.
JOIST UNDER.
DATE
June 07
DRAWN
Autocad2000/
DRAWING NUMBER
016
C