© 2015 Kadant Solutions Paper Dryer Doctoring
Paper Dryer Doctoring
Technical White Paper Series
Gregory L. Wedel
President
Kadant Johnson Inc.
Mohan Jayaraman
Manager, Research & Development
Kadant Solutions Division
© 2015 Kadant Solutions Paper Dryer Doctoring
Introduction
Doctor Blade Materials and Applications
Doctor Blade Holders
Doctor Backs
Doctor Oscillators
Doctor Blade Alignment
Doctor Blade Load
Doctor Blade Functions
Drive Power
Heat Transfer
Doctor Blade Recommendations
Conclusions
3
3
5
8
9
10
11
11
13
14
16
17
CONTENTS
EXECUTIVE SUMMARY
Dryer doctors have a number of purposes in a paper machine dryer section: sheet shedding,
dryer surface cleaning, threading, and air handling and control. Paper dryer doctors are often
overlooked in the papermaking process, but they need proper attention to maintain efficient
dryer operation. This paper covers the main considerations in applying and servicing dryer
doctors.
2
© 2015 Kadant Solutions Paper Dryer Doctoring
INTRODUCTION
3
DOCTOR BLADE MATERIALS AND APPLICATIONS
Doctor blades can be metallic, composite, or plastic. The most common
metallic blades are bronze, steel, and Monel. Bronze blades are used to
burnish new dryers. Steel blades are used for most intermediate dryer
doctor applications. Monel blades are not normally used on paper dry-
ers.
Composite blades are reinforced with fiber. Most common blade con-
structions utilize fiberglass, carbon fiber, a combination of the two, or
Kevlar. The resin (i.e., glue) that holds the fibers together is typically a
high temperature epoxy. Ceramic and other exotic materials are used
for specific applications. When the dryer surface is dirty, it is common
to use abrasive blades containing silicon carbide.
When there is no fiber reinforcement in the doctor blade, the blade is
most commonly referred to as a plastic blade. Because of temperature
limitations, plastic blades are not used on paper dryers.
From an application perspective, bronze blades are generally used to
burnish the surface of new dryers or dryers that have been recently re-
ground. These blades wear rapidly on dryers that run at high speed
A dryer doctor blade is a cross-machine scraping device that is held in
direct contact with the dryer surface. The doctor blade is held in a hold-
er that is mounted to a cross machine beam type structure called a doc-
tor back. The doctor back is mounted on journals that are supported by
self-aligning bearings on the front and back dryer frames. The doctor
back pivots on these journals, loading the doctor blade against the out-
side surface of the dryer, by gravity, by end-loading cylinders, or by
pivoting blade holders (in which case the doctor back should be held
firmly in place with turnbuckles).
Doctoring systems are designed for specific applications. The applica-
tion variables include blade loading, required reliability, roll tempera-
ture, sheet shedding needs, cleaning requirements, and expected wear
life. When selecting a component or system, the application or duty
requirement must be clearly outlined.
The penalty for doctor neglect includes roll damage, poor sheet quality,
low machine efficiency, high draws, sheet breaks, and damage to doc-
tors and adjacent machine clothing.
From an application
perspective, bronze
blades are generally
used to burnish the
surface of new
dryers or dryers
that have been
recently reground.
© 2015 Kadant Solutions Paper Dryer Doctoring 4
and are usually replaced after burnishing. In the past, the replacement
blades were steel. Today, it is most common to use composite blades
that are designed specifically for continuous operation. Excessive use of
bronze blades may lead to build up of bronze deposits on the dryer sur-
face, causing runnability and doctoring problems.
In high-speed applications, most steel blades will experience increased
wear rates and over time will wear the surface of the dryer cylinder.
Also, at high speeds steel blades tend to spark, causing a fire hazard.
Non-metallic composite blades are often used to minimize the wear of
the dryer surface and to reduce the dryer drive load. As a general rule,
composite blades do not spark. In recent years, dryer cylinders, espe-
cially after-coater dryers and dryers in lead-in positions, have been
coated with Tungsten carbide and a surface release coating. The release
coatings are often Teflon or silicone based. Composite blades are
strongly recommended for these applications.
A recent doctor blade development for critical dryer applications is the
carbide tipped blade. Carbide tipped bronze blades are used to help
clean stickies off dryer cans. Baby dryers and other lead-in dryers are
candidates for these blades because stickies have a special affinity for
these dryers. Carbide tipped blades are self-sharpening, and carbide at
the tip of the blade provides a continuous sharp edge that literally cuts
under the stickies and scrapes them off the dryer surface. These blades
are also very helpful on critical dryers after a coater section to clean
coating color off the dryer surfaces.
Another recent innovation is a composite blade with a thermally
sprayed carbide tip. This blade does not spark even in severe duty ap-
plications.
An even more recent doctor blade development used nano materials to
further enhance the doctoring performance and doctor blade life. The
inclusion of micro particulate materials in the resin matrix provides
these enhancements with a highly homogeneous structure. The resin
matrix, enhanced with nano materials, is engineered to maintain a
strong leading edge for effective and consistent dryer surface doctoring.
This results in fewer blade changes, lower operating costs, and efficient
surface cleaning. Nanotechnology enhanced blades are applied where
the removal of dryer surface contaminants is particularly difficult and
where long doctor blade life is required.
In high-speed
applications,
most steel blades
will experience
increased wear
rates and over
time will wear the
surface of the
dryer cylinder.
© 2015 Kadant Solutions Paper Dryer Doctoring 5
Doctor blade holders are also designed for specific applications. A rigid
holder is generally used for light-duty applications or in positions
where the penalty for neglect is not high. Rigid holders are often used
in intermediate paper dryer positions. Rigid holders are not recom-
mended for sheet shedding (i.e., take-off) positions. Most rigid holders
are bolted directly to the doctor back. In order to replace a rigid holder, the
doctor back must often be removed from the machine.
Recent advancements, however, have made it easier to maintain or
change holders should the need arise. Holders that are mounted on T-
slide systems are quickly becoming the norm rather than the exception.
A Unimate™ doctor blade holder is bolted every three inches
into the doctor back. To replace the holder, all the bolts have
to be removed.
A UniSlide™ doctor blade holder has an interlocking T-slide
mounting so the holder can be removed from the doctor back
without removing any fastening bolts.
Doctor blades are held securely in rigid holders and the blade tips de-
flect to fit the profile of the mating rolls. If the blade fit is poor, either
due to a bent doctor back, a heavy roll crown, doctor misalignment, a
damaged holder, or a worn roll profile, the doctoring efficiency will be
poor. Additionally, these rigid holders do not have rotational flexibility
in the cross machine direction. Hence, holders that are set up with a
small misalignment, off level or off square to the roll, will have difficul-
ty in conforming to the roll.
All these negative influences generally have an additive effect, so while
each issue might be small, there may still be a major roll-to-blade fit
problem. Hence, each problem needs to be addressed. Increasing blade
loading is not recommended for improving the blade fit, except as a
very short-term solution. Increasing loading to achieve a better blade fit
results in increased wear of both the doctor blade and the roll surface.
More sophisticated blade holders have a self-conforming feature. These
holders automatically adjust to match the roll crown or non-uniform
roll diameters. These are the “DST” class of holders. These conforming
styles of blade holders are held to the doctor back with a series of pivot
pins. The doctor back is held in its operating position by a pair of turn-
buckles. A cross-machine pneumatic tube is positioned under one end
DOCTOR BLADE HOLDERS
© 2015 Kadant Solutions Paper Dryer Doctoring 6
of the pivoting holder. When this tube is inflated, it pivots the holder,
pressing the blade against the roll surface. These holders are flexible so
that the blade loading will be uniform in the cross-machine direction.
Conforming holders are often used in critical dryer doctor positions
(e.g., first and last dryers). Adjusting the pressure in the tube directly
affects the blade pressure. Most conforming holders have two tubes:
one to load the blade and the other to unload the blade. The unload
tube can be partially pressurized during operation to help seal the in-
sides of the holder and keep it clean.
A discussion on holders would be incomplete without a brief descrip-
tion of what some consider a paradigm shift in holder technology: inte-
grating T-Slides into conforming holders to improve their maintenance
and repair. This has allowed conforming holders to be used in locations
where previously only rigid or direct mount holders had been used. An
example of a T-slide mounting is shown below in Figure 1.
Fig 1 is a schematic of the Kadant UniSet ™ doctor blade
holder. [A] The tube tray can slide out of the machine while
the T-bar remains attached to the doctor back. This greatly
reduces the time required to service the holder. [B] The
pivot rod has continuous contact in the cross direction,
providing a tight fit, reducing vibration and improving
loading uniformity. [C] The integral top plate is conform-
ing and able to reliably shed the sheet in tough applica-
tions.
C
A
B
© 2015 Kadant Solutions Paper Dryer Doctoring 7
The effectiveness of a conforming blade holder is shown in the follow-
ing figure. With a rigid holder, the blade is unable to apply pressure to
the shell over a groove in a shell with a 200” face, even though the
groove is only 0.010” deep and 40” wide. Eventually, the blade will
wear unevenly and into the groove, but this is far from the ideal solu-
tion. The DST holder, on the other hand, is able to apply a more uni-
form pressure, even on the damaged area of the roll surface.
Similarly, a conforming blade holder can accommodate a 0.030” total
crown on a press roll, whereas a conventional rigid holder cannot.
This is shown in the figure below.
© 2015 Kadant Solutions Paper Dryer Doctoring 8
DOCTOR BACKS
The doctor back may be a simple angle iron or a more elaborate weld-
ed structure. Most doctor backs are either triangular or rectangular in
shape, custom-designed for each dryer pocket. The back must meet
specific stiffness and deflection criteria, to avoid vibration and chatter.
Mounting surfaces are machined on the doctor backs for the blade
holders. Doctor backs that are machined for operating below top dry-
ers will often be different than the doctor backs that are machined for
operating above bottom dryers. This is because of the position of the
pivot and the direction of the deflection of the doctor back.
It is important, particularly for doctors in top dryer positions, to be
able to deal with debris that comes off the roll on the underside of the
doctor blade. If a doctor back has a shelf, unwanted debris can collect
and create a potential fire hazard and can increase the risk of a doctor
jam if the sheet passes under the doctor blade. Modern doctor backs
have surfaces that facilitate the fall-off of such debris.
Old Design New Design (Patent Pending)
© 2015 Kadant Solutions Paper Dryer Doctoring 9
DOCTOR OSCILLATORS
Doctor backs are often oscillated using pneumatic or electrical actua-
tors. This oscillation helps to cut debris that has collected under the
blade and spread out any tendency for the blade to wear narrow bands
on the dryer cylinder surface.
Oscillating frequencies are quite low, typically only 5 to 15 cycles per
minute with a stroke of 12 to 18 mm. Some oscillation strokes can be
lower in stroke distance (e.g., 6 mm), but higher in frequency.
Electromechanical oscillators have been the workhorse of the industry
for many years. In many parts of the world, such as Europe and Asia,
they are still regularly used. These oscillators are reliable in operation
and are relatively trouble-free.
In North America, pneumatic oscillation is preferred for many reasons,
including: (1) uninterrupted supply of clean filtered air is economically
available for continuous use, (2) oscillation stroke length and frequency
can be set per application requirements, and (3) the compact design fits
into many locations where real estate is a premium at the end of a doc-
tor back (such as between machine frames).
Kadant Varimatic™ pneumatic oscillator. Kadant electromechanical oscillator.
© 2015 Kadant Solutions Paper Dryer Doctoring 10
DOCTOR BLADE ALIGNMENT
In order to achieve consistent and reliable doctor performance, the doc-
tor blade must be properly set up, carefully aligned, and correctly fitted
to the roll surface. A new blade should be set up to contact the roll sur-
face in a line that is parallel to the dryer axis. The journals of the doctor
back should then be parallel and level with the dryer axis as well. The
blade pressure on the dryer surface should be uniform in the cross-
machine direction.
The blade angle on dryer doctors is typically set to 25° to 30°. This angle
is especially important on sheet shedding positions, where the recom-
mended angle is about 28°. Blade angles are easily measured using
modern digital gauges as shown in the figure below.
The most common device for setting doctor
blade angles is the AngleSet™ gauge. This
photograph shows the unit being used to take
reading on a roll. The compact gauge is handy
for taking readings in cramped locations such
as secondary positions on double doctors.
© 2015 Kadant Solutions Paper Dryer Doctoring 11
DOCTOR BLADE LOAD
Typical dryer doctor blade loading is 0.75 pli except for sheet shedding
positions, such as the first and last dryers of a dryer section. The sheet
shedding doctors are typically loaded 1.5 to 2.5 pli. If the cleaning duty
is high, or if the sheet has a tendency to stick to the dryer surface, high-
er blade loads and blade angles are recommended. However, when the
load is going to be increased, a new blade should be used to prevent the
tip of the blade from “bird-mouthing” as shown in the figure below. On
a sheet shedding position, it is extremely important to install a new
blade before increasing the blade loading, to prevent sheet wrap-ups
and damage to the blade, doctor, holder, and machine clothing.
DOCTOR BLADE FUNCTIONS
Doctor blades can affect sheet quality and production, both positively
and negatively. In general, doctors blades are used to keep the outside
surfaces of paper dryers clean. The blades are also used to control air
flows, assist with tail threading, and prevent sheet wraps and resulting
felt damage.
Surface cleaning. Uniform build-up on the dryer surfaces can cause a
loss in heat transfer; over 5% on those dryers with heavy build-up. Non
-uniform build-up can cause local small-scale variations in drying, that
result in cockles and puffy paper. The build-up of stickies can cause
sheet surface defects, such as fiber picks and linting. To avoid these
problems, the dryer surfaces must be kept clean.
Contaminated dryer surfaces can also cause the sheet to stick to the
dryer surface. Lightweight grades in particular often tend to stick to the
© 2015 Kadant Solutions Paper Dryer Doctoring 12
dryer surface and follow it for a short distance, rather than following
the tangent path to the next dryer cylinder. This phenomenon, referred
to as sheet stealing, can have an adverse effect on sheet runnability.
Cleaning the dryer surface can reduce this effect, but the surfaces must
be particularly clean to be effective.
Chrome plating has been used in the past in an attempt to prevent
stickies from forming on the dryer surface. Unfortunately, the chrome
plating has not proven to be effective in preventing the build-up of
stickies, and carbide tipped blades cannot be used on chrome surfaces
without a risk of damage to the surface. Teflon-infused carbide coatings
on dryer can surfaces are more effective in reducing the build-up of
stickies, and these surfaces can be effectively doctored as well.
The cleanliness of the dryer surface can be maintained by continuous
doctoring, by periodic loading of the blade (typically during a sheet
break or prior to start-ups), or by chemical cleaning during extended
shutdowns.
Dryer doctors can cause dusting, particularly when running on wet end
dryers where there is a lot of fiber picking. The dust and debris that is
doctored from the sheet can fall onto the wet paper. If the paper is later
coated, this debris can cause coater scratches and sheet breaks. Many
coated paper machines will run with the doctor blades unloaded to pre-
vent dusting. The dryers are periodically cleaned by loading the doctor
blades during sheet breaks and then unloading them after threading
the machine.
Controlling air flow. When the doctor blade is loaded, or when it is run-
ning close to the dryer surface, it tends to reduce the amount of air that
is entrained by the moving dryer surface. This can reduce windage and
pumping, reducing sheet flutter and sheet disturbances. If the doctor
blade is unloaded, however, it is possible for the air velocity to be in-
creased, even though the amount of air that is entrained is reduced.
Tail threading. On high-speed machines, the location of the blade, the
contour of the blade holder, and the shape of the doctor back are often
designed to help direct the tail from one dryer to the next. With the as-
sistance of edge air nozzles, the tail can in some cases be threaded with-
out the use of threading ropes.
Sheet wraps. If the sheet follows the dryer after a sheet break, it is called
a sheet wrap. The sheet wrap can be blown off the dryers with high-
pressure air hoses, provided the sheet is a lightweight grade (such as
newsprint) with a limited amount of wrap on the dryer. If the wrap is
thick, and in particular if the wrap is a heavy weight board grade, it can
take a long time to clear the wrap off the dryer. Oftentimes the dryer
section must be stopped, the wrap “speared” off the dryer, and the slab
of paper walked slowly down the machine to a section break, where it
can be dropped into the basement. In both cases, there is a risk of dam-
aging the dryer fabric, either from wads or from the broke poles.
The cleanliness of
the dryer surface
can be maintained
by continuous
doctoring, by
periodic loading
of the blade, or by
chemical cleaning
during extended
shutdowns.
© 2015 Kadant Solutions Paper Dryer Doctoring
Sheet wraps can be prevented by having the dryer doctors loaded when
the sheet break occurs. If the blade loading is inadequate, if the blade fit
is not tight, or if the blade bevel angle is open at the tip, the sheet can
pass under the blade and wrap the dryer. A dryer wrap with a loaded
doctor blade can take hours to clear. If the paper is badly jammed be-
tween the doctor back and the dryer, it may be necessary to dismount
the doctor back and move it away from the surface to provide clearance
for removing the broke. The shape of the doctor back can aggravate or
minimize the severity of this type of “jam-up.”
13
DRIVE POWER
The doctor load on the dryer surface produces a drag that must be
overcome by the dryer drive motor. The drive load produced by the
dryer doctors depends on the speed of the machine, the width of the
dryers, the number of doctor blades that are loaded, the amount of
blade load (pli), the blade material, the surface condition of the dryer,
and the moisture content of the paper. The affect of each of these varia-
bles on the drive load is not well publicized, but general guidelines are
available.
A typical guideline for drive load is the factor 0.0007 Hp per inch per
100 fpm of speed, for each pli of blade loading. For example, a 350” face
dryer that is running 3500 fpm would be expected to add about 4.3 hp
to the drive load when the blade is loaded to 0.5 pli:
Hp = (0.0007 Hp/inch/100 fpm/pli) x (350 inches) x (3500 fpm) x (0.5
pli) = 4.3
The drive load factor ranges from 0.0006 to 0.0012, with the lower val-
ues typical for low-friction synthetic carbon fiber containing blades and
the higher values typical for conventional glass blades.
The graph on the following page compares the drive power for three
types of doctor blades: cotton phenolic (Lamflex™ doctor blade), steel,
and a modern low-friction blade material. All three materials are capa-
ble of cleaning the dryer surface, but with significantly different friction
factors.
The Lamflex blade is a cotton phenolic blade, one of the first synthetic
laminate blades on the market. A modern low-friction blade, such as
SynTek doctor blade, will consume much less drive power than a Lam-
flex blade. For example, with an electrical cost of $0.07 / kWh, a 350”
wide paper machine running at 4,000 fpm will use (34-12) hp x 0.745
kW/hp x 24 hr/day x 325 operating days/yr x $0.07 / kWh= $8,950
more in electrical costs, per dryer, for a Lamflex blade than for a low-
friction blade.
© 2015 Kadant Solutions Paper Dryer Doctoring 14
Syntek
As noted earlier, dryers with heavy build-up can cause a loss in drying
capacity. A typical board or paper dryer with a uniform build-up of
0.01” of paper fiber might lose 2 to 3% of its normal drying capacity. A
uniform build-up of 0.05”of fiber might cause a loss in capacity of up to
10 to 15%, on those dryers that have this amount of build-up.
Build-up on dryers can consist of various amounts of fiber, starch, size,
coating inorganic materials, latex, pitch, hot-melt adhesives (i.e., stick-
ies), rust, and other contaminants. The best cure for dryer build-up is
prevention. Continuous dryer doctoring can often prevent contamina-
tion from becoming a problem. The doctoring system, however, must
be tailored to address the type of build-up that is causing the problem.
The build up of stickies on the early dryers is rarely uniform and is of-
tentimes a problem. It is not uncommon to have "buttons" of stickies on
the dryer felts as well as on the dryer surfaces. Stickies cause a loss in
runnability (sheet stealing, tear-outs, sheet breaks, poor transfers, lim-
ited speed) and sheet defects such as picked fibers, wrinkles, folds,
sheet roughness, cockling, and poor moisture profile. Dryer fabric
cleaning is just as important as dryer surface cleaning. There are a num-
ber of products in the market for dryer fabric cleaning.
HEAT TRANSFER
© 2015 Kadant Solutions Paper Dryer Doctoring 15
The M-clean™ cleaning system uses high-pressure water
in combination with an effective evacuation and air knife
system. The water pressure is optimized to ensure opti-
mum cleaning, and other factors – such as the final dry-
ness of the cleaned surface – can be adjusted individually
for each paper machine. It cleans during production
without leaving moisture streaks or in any other way
negatively affecting the paper quality. No chemicals or
other additional ingredients are necessary. In addition,
there is no contact with the surface other than from the
air and water jets.
With respect to dryer surface cleaning, the build up of fibers and inor-
ganic materials can be much heavier than stickies and even fairly uni-
form. This build-up reduces drying capacity, although steam pressures
in early dryers are often reduced anyway, to minimize the picking. A
dryer doctor will remove stickies, fiber, and inorganic build-up from
dryer surfaces, but this does not necessarily eliminate the tendency for
fibers to pick. Even though the dryer surface looks clean, there can still
be thin layers of stickie material smeared on the dryer that cause fiber
picking and sheet stealing.
Recent developments in doctor blade materials have allowed paper
mills to clean even heavy build-up from dryers and, with proper blade
selection for continuous operation, to keep the dryers clean. Alterna-
tives to periodic doctoring are periodic chemical cleaning, continuous
chemical passivation of the dryer surfaces, and mechanical cleaning.
Mechanical cleaning includes blasting with sand, soda ash, or dry ice.
Build-up can also be cleaned off by periodic grinding and by chemical
cleaning. Chemical cleaning removes fiber and other surface contami-
nants, but it does not restore the dryer surface profile. The dryer surface
© 2015 Kadant Solutions Paper Dryer Doctoring 16
profile can be leveled with surface grinding, although this takes an ex-
tended downtime, reduces the shell code thickness, and can be quite
costly. In some cases, dryer surfaces can be improved by careful use of
abrasive cleaning blades, extending the dryer life and possibly avoiding
the cost of grinding the surface.
It is also possible to reduce the tendency for contaminants to stick to the
dryer surface by chemical means. The chemical passivation fluid is ap-
plied continuously and directly to either the dryer felt rolls or to the
dryer surfaces. The chemicals can be applied with a single traversing
nozzle or a series of spraying nozzles mounted to a cross-machine
header pipe. These can be costly measures, but justified in severe cases.
DRYER DOCTOR BLADE RECOMMENDATIONS
Doctor Blade Features Applications
DriTek ™ Steel blade 100% steel
Ceramic coating
Increased tip strength
Reliable sheet shedding
Heavy duty dryer cylinder cleaning, last top
and after-coater dryers, stickies and coating
removal
DriTek™ Bronze blade 100% bronze
Ceramic coating
Increased tip strength
Minimize sparking
Reliable sheet shedding
Heavy duty dryer cylinder cleaning, last top
and after-coater dryers, stickies and coating
removal
Nanotechnology
Enhanced blades
Nanotechnology-enhance resin
Cross-machine flexibility
Long life
No sparking
Heavy duty dryer cylinder cleaning, last top
and after-coater dryers, stickies and coating
removal
SynTek™ Plus blade Carbon / glass fiber
Performance resin
Operating temp 400 F
Low friction coefficient
Press roll and dryer cleaning, last top and
after-coater dryers, stickies and coating re-
moval
ArmorTek™ blade Metal blade
Proprietary coating
Low friction coefficient
Corrosion resistant
Sheet shedding positions/intermediate cans,
replaces mild and stainless steel blades
Abrasitek™ blade Cleaning / polishing blade kit
Abrasive particles on blade
0.250” reverse bevel
Yankee dryer surface conditioning, severe
dryer contamination, reduce chatter marks,
increase time between grinds
© 2015 Kadant Solutions Paper Dryer Doctoring 17
Doctoring equipment should be selected after a careful review of the
application and duty requirements. This application review should be
conducted by a specialist in doctoring technologies, who can pinpoint
problem areas and offer the paper maker practical solutions and operat-
ing recommendations.
For dryers that are particularly difficult to clean, such as lead-in dryers,
baby dryers, or the first position where the sheet is first exposed to dry-
er heat, a fluid-backed doctor holder and a carbide-tipped blade loaded
at about 2 pli is recommended.
For last dryer positions, carbide-tipped blades or other carbon contain-
ing blades loaded at a minimum of 1.5 pli are recommended. A slide-
out feature improves the ease of maintaining or changing the holder in
case of damage. Oscillation, in all cases, is recommended.
CONCLUSIONS

Weitere ähnliche Inhalte

Was ist angesagt?

Final version training
Final version trainingFinal version training
Final version training
SappiHouston
 
3 A Papermachine Steam Systems Part1
3 A Papermachine Steam Systems Part13 A Papermachine Steam Systems Part1
3 A Papermachine Steam Systems Part1
Nhan Vo Trong
 
Drying training Equipment Operation and control
Drying training Equipment Operation and control Drying training Equipment Operation and control
Drying training Equipment Operation and control
Nelson Izaguirre
 

Was ist angesagt? (20)

Heat Transfer Performance with Dryer Bars
Heat Transfer Performance with Dryer BarsHeat Transfer Performance with Dryer Bars
Heat Transfer Performance with Dryer Bars
 
optimization of wire vacuum
optimization of wire vacuumoptimization of wire vacuum
optimization of wire vacuum
 
Crescentformer general process. tissue machine Voith
Crescentformer general process. tissue machine VoithCrescentformer general process. tissue machine Voith
Crescentformer general process. tissue machine Voith
 
Engineering aspects of basis weight control
Engineering aspects of basis weight controlEngineering aspects of basis weight control
Engineering aspects of basis weight control
 
Troubleshooting Flooding of Paper Dryers
Troubleshooting Flooding of Paper DryersTroubleshooting Flooding of Paper Dryers
Troubleshooting Flooding of Paper Dryers
 
Creping. Tissue machine creping
Creping. Tissue machine crepingCreping. Tissue machine creping
Creping. Tissue machine creping
 
Paper Drying Energy Tips
Paper Drying Energy TipsPaper Drying Energy Tips
Paper Drying Energy Tips
 
Case studies related_to_paper_machine_operation
Case studies related_to_paper_machine_operationCase studies related_to_paper_machine_operation
Case studies related_to_paper_machine_operation
 
Final version training
Final version trainingFinal version training
Final version training
 
Dryer Condensing Loads Following Sheet Breaks
Dryer Condensing Loads Following Sheet BreaksDryer Condensing Loads Following Sheet Breaks
Dryer Condensing Loads Following Sheet Breaks
 
Potlatch Brainerd Wet End Training 3
Potlatch Brainerd Wet End Training 3Potlatch Brainerd Wet End Training 3
Potlatch Brainerd Wet End Training 3
 
Cold Shutdown of Paper Dryers
Cold Shutdown of Paper DryersCold Shutdown of Paper Dryers
Cold Shutdown of Paper Dryers
 
Determination of doctor angle
Determination of doctor angleDetermination of doctor angle
Determination of doctor angle
 
Bel champ 15 july 2020
Bel champ 15 july 2020Bel champ 15 july 2020
Bel champ 15 july 2020
 
3 A Papermachine Steam Systems Part1
3 A Papermachine Steam Systems Part13 A Papermachine Steam Systems Part1
3 A Papermachine Steam Systems Part1
 
Modern papermaking feb 2018 pdf
Modern papermaking feb 2018 pdfModern papermaking feb 2018 pdf
Modern papermaking feb 2018 pdf
 
Understanding Paper Dryer Rotary Joint Reliability
Understanding Paper Dryer Rotary Joint ReliabilityUnderstanding Paper Dryer Rotary Joint Reliability
Understanding Paper Dryer Rotary Joint Reliability
 
Drying training Equipment Operation and control
Drying training Equipment Operation and control Drying training Equipment Operation and control
Drying training Equipment Operation and control
 
Rewinder 15 aug 2018
Rewinder  15 aug 2018Rewinder  15 aug 2018
Rewinder 15 aug 2018
 
WATER JET WEAVING MACHINE
WATER JET WEAVING MACHINEWATER JET WEAVING MACHINE
WATER JET WEAVING MACHINE
 

Andere mochten auch (7)

Valmet moving forward with clean technologies niemelä
Valmet moving forward with clean technologies niemeläValmet moving forward with clean technologies niemelä
Valmet moving forward with clean technologies niemelä
 
Improved Dryer Control
Improved Dryer ControlImproved Dryer Control
Improved Dryer Control
 
Vacuum pump-sizing
Vacuum pump-sizingVacuum pump-sizing
Vacuum pump-sizing
 
211053940 mechanisms-for-projects-drawings-pr-pdf
211053940 mechanisms-for-projects-drawings-pr-pdf211053940 mechanisms-for-projects-drawings-pr-pdf
211053940 mechanisms-for-projects-drawings-pr-pdf
 
Paper cutting & rewinding machine project report sreesangh p ghosh
Paper cutting & rewinding machine   project report sreesangh p ghoshPaper cutting & rewinding machine   project report sreesangh p ghosh
Paper cutting & rewinding machine project report sreesangh p ghosh
 
Paper cutting & rewinding machine project report SREESANGH P GHOSH
Paper cutting & rewinding machine   project report SREESANGH P GHOSHPaper cutting & rewinding machine   project report SREESANGH P GHOSH
Paper cutting & rewinding machine project report SREESANGH P GHOSH
 
Vacuum system
Vacuum systemVacuum system
Vacuum system
 

Ähnlich wie Paper Dryer Doctoring

Fishbone Article Pumps and Systems
Fishbone Article Pumps and SystemsFishbone Article Pumps and Systems
Fishbone Article Pumps and Systems
Dwight Bertozzi
 
INSERTS FOR PLASTICSF Lτ = F x LInserts.docx
INSERTS FOR PLASTICSF                    Lτ = F x LInserts.docxINSERTS FOR PLASTICSF                    Lτ = F x LInserts.docx
INSERTS FOR PLASTICSF Lτ = F x LInserts.docx
dirkrplav
 

Ähnlich wie Paper Dryer Doctoring (20)

Basics of Self-Supported Rotary Joint Installation on Steam-Heated Paper Dryers
Basics of Self-Supported Rotary Joint Installation on Steam-Heated Paper DryersBasics of Self-Supported Rotary Joint Installation on Steam-Heated Paper Dryers
Basics of Self-Supported Rotary Joint Installation on Steam-Heated Paper Dryers
 
Improving the Reliability of MECHANICAL SEALS
Improving the Reliability of MECHANICAL SEALSImproving the Reliability of MECHANICAL SEALS
Improving the Reliability of MECHANICAL SEALS
 
Analysis of hydrodynamic fixed pad bearing to reduce vibration by replacing f...
Analysis of hydrodynamic fixed pad bearing to reduce vibration by replacing f...Analysis of hydrodynamic fixed pad bearing to reduce vibration by replacing f...
Analysis of hydrodynamic fixed pad bearing to reduce vibration by replacing f...
 
IRJET- Smart Water Tank Cleaning Machine for Household Applications
IRJET- Smart Water Tank Cleaning Machine for Household ApplicationsIRJET- Smart Water Tank Cleaning Machine for Household Applications
IRJET- Smart Water Tank Cleaning Machine for Household Applications
 
1.seal mechanical seal
1.seal mechanical seal1.seal mechanical seal
1.seal mechanical seal
 
IRJET- Design and Development of Collet Chuck
IRJET- Design and Development of Collet ChuckIRJET- Design and Development of Collet Chuck
IRJET- Design and Development of Collet Chuck
 
Fishbone Article Pumps and Systems
Fishbone Article Pumps and SystemsFishbone Article Pumps and Systems
Fishbone Article Pumps and Systems
 
What is the difference between Rotary Joints and Rotary Unions.pptx
What is the difference between Rotary Joints and Rotary Unions.pptxWhat is the difference between Rotary Joints and Rotary Unions.pptx
What is the difference between Rotary Joints and Rotary Unions.pptx
 
IRJET- Cleaning Mechanism for Cylindrical Tank
IRJET- Cleaning Mechanism for Cylindrical TankIRJET- Cleaning Mechanism for Cylindrical Tank
IRJET- Cleaning Mechanism for Cylindrical Tank
 
How to unlock productivity savings in mining operations part 3 final_11.06.2017
How to unlock productivity savings in mining operations part 3 final_11.06.2017How to unlock productivity savings in mining operations part 3 final_11.06.2017
How to unlock productivity savings in mining operations part 3 final_11.06.2017
 
Air bearings dcoumentation
Air bearings dcoumentationAir bearings dcoumentation
Air bearings dcoumentation
 
Hard Turning
Hard TurningHard Turning
Hard Turning
 
Selection of bearing_clearance
Selection of bearing_clearanceSelection of bearing_clearance
Selection of bearing_clearance
 
Design of Mechanical Crushing Machine
Design of Mechanical Crushing MachineDesign of Mechanical Crushing Machine
Design of Mechanical Crushing Machine
 
Monitoring plain bearings with ultrasound
Monitoring plain bearings with ultrasoundMonitoring plain bearings with ultrasound
Monitoring plain bearings with ultrasound
 
Industrial Bearings Boost Efficiency -Exploring Types and Benefits - Powerdri...
Industrial Bearings Boost Efficiency -Exploring Types and Benefits - Powerdri...Industrial Bearings Boost Efficiency -Exploring Types and Benefits - Powerdri...
Industrial Bearings Boost Efficiency -Exploring Types and Benefits - Powerdri...
 
How to-choose-air-rotor-the-ultimate-guide-converted
How to-choose-air-rotor-the-ultimate-guide-convertedHow to-choose-air-rotor-the-ultimate-guide-converted
How to-choose-air-rotor-the-ultimate-guide-converted
 
Mechanical Face Seals Design for Differential Pressure Applications
Mechanical Face Seals Design for Differential Pressure ApplicationsMechanical Face Seals Design for Differential Pressure Applications
Mechanical Face Seals Design for Differential Pressure Applications
 
INSERTS FOR PLASTICSF Lτ = F x LInserts.docx
INSERTS FOR PLASTICSF                    Lτ = F x LInserts.docxINSERTS FOR PLASTICSF                    Lτ = F x LInserts.docx
INSERTS FOR PLASTICSF Lτ = F x LInserts.docx
 
Cane V2
Cane V2Cane V2
Cane V2
 

Mehr von Kadant Inc.

Mehr von Kadant Inc. (6)

Be Original: The Path to LC Paper's OnePly Tissue
Be Original: The Path to LC Paper's OnePly TissueBe Original: The Path to LC Paper's OnePly Tissue
Be Original: The Path to LC Paper's OnePly Tissue
 
James Cropper Specialty papers unique experience producing luxury boards with...
James Cropper Specialty papers unique experience producing luxury boards with...James Cropper Specialty papers unique experience producing luxury boards with...
James Cropper Specialty papers unique experience producing luxury boards with...
 
Recovering Thermal Energy with Water Jet Heaters
Recovering Thermal Energy with Water Jet HeatersRecovering Thermal Energy with Water Jet Heaters
Recovering Thermal Energy with Water Jet Heaters
 
Vibration Characteristics in Cantilever Stationary Syphons
Vibration Characteristics in Cantilever Stationary SyphonsVibration Characteristics in Cantilever Stationary Syphons
Vibration Characteristics in Cantilever Stationary Syphons
 
Paper Machine Whitewater Reuse
Paper Machine Whitewater ReusePaper Machine Whitewater Reuse
Paper Machine Whitewater Reuse
 
Effectiveness of Paper Dryer Journal Insulating Sleeves
Effectiveness of Paper Dryer Journal Insulating SleevesEffectiveness of Paper Dryer Journal Insulating Sleeves
Effectiveness of Paper Dryer Journal Insulating Sleeves
 

Kürzlich hochgeladen

Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers:  A Deep Dive into Serverless Spatial Data and FMECloud Frontiers:  A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Safe Software
 

Kürzlich hochgeladen (20)

Automating Google Workspace (GWS) & more with Apps Script
Automating Google Workspace (GWS) & more with Apps ScriptAutomating Google Workspace (GWS) & more with Apps Script
Automating Google Workspace (GWS) & more with Apps Script
 
Apidays New York 2024 - The value of a flexible API Management solution for O...
Apidays New York 2024 - The value of a flexible API Management solution for O...Apidays New York 2024 - The value of a flexible API Management solution for O...
Apidays New York 2024 - The value of a flexible API Management solution for O...
 
Manulife - Insurer Transformation Award 2024
Manulife - Insurer Transformation Award 2024Manulife - Insurer Transformation Award 2024
Manulife - Insurer Transformation Award 2024
 
2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...
 
Apidays Singapore 2024 - Scalable LLM APIs for AI and Generative AI Applicati...
Apidays Singapore 2024 - Scalable LLM APIs for AI and Generative AI Applicati...Apidays Singapore 2024 - Scalable LLM APIs for AI and Generative AI Applicati...
Apidays Singapore 2024 - Scalable LLM APIs for AI and Generative AI Applicati...
 
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemkeProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
 
AWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of TerraformAWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of Terraform
 
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
 
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
 
Polkadot JAM Slides - Token2049 - By Dr. Gavin Wood
Polkadot JAM Slides - Token2049 - By Dr. Gavin WoodPolkadot JAM Slides - Token2049 - By Dr. Gavin Wood
Polkadot JAM Slides - Token2049 - By Dr. Gavin Wood
 
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers:  A Deep Dive into Serverless Spatial Data and FMECloud Frontiers:  A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
 
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot TakeoffStrategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
 
"I see eyes in my soup": How Delivery Hero implemented the safety system for ...
"I see eyes in my soup": How Delivery Hero implemented the safety system for ..."I see eyes in my soup": How Delivery Hero implemented the safety system for ...
"I see eyes in my soup": How Delivery Hero implemented the safety system for ...
 
Exploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone ProcessorsExploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone Processors
 
AXA XL - Insurer Innovation Award Americas 2024
AXA XL - Insurer Innovation Award Americas 2024AXA XL - Insurer Innovation Award Americas 2024
AXA XL - Insurer Innovation Award Americas 2024
 
Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024
 
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobe
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, AdobeApidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobe
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobe
 
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost SavingRepurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
Repurposing LNG terminals for Hydrogen Ammonia: Feasibility and Cost Saving
 
Powerful Google developer tools for immediate impact! (2023-24 C)
Powerful Google developer tools for immediate impact! (2023-24 C)Powerful Google developer tools for immediate impact! (2023-24 C)
Powerful Google developer tools for immediate impact! (2023-24 C)
 
FWD Group - Insurer Innovation Award 2024
FWD Group - Insurer Innovation Award 2024FWD Group - Insurer Innovation Award 2024
FWD Group - Insurer Innovation Award 2024
 

Paper Dryer Doctoring

  • 1. © 2015 Kadant Solutions Paper Dryer Doctoring Paper Dryer Doctoring Technical White Paper Series Gregory L. Wedel President Kadant Johnson Inc. Mohan Jayaraman Manager, Research & Development Kadant Solutions Division
  • 2. © 2015 Kadant Solutions Paper Dryer Doctoring Introduction Doctor Blade Materials and Applications Doctor Blade Holders Doctor Backs Doctor Oscillators Doctor Blade Alignment Doctor Blade Load Doctor Blade Functions Drive Power Heat Transfer Doctor Blade Recommendations Conclusions 3 3 5 8 9 10 11 11 13 14 16 17 CONTENTS EXECUTIVE SUMMARY Dryer doctors have a number of purposes in a paper machine dryer section: sheet shedding, dryer surface cleaning, threading, and air handling and control. Paper dryer doctors are often overlooked in the papermaking process, but they need proper attention to maintain efficient dryer operation. This paper covers the main considerations in applying and servicing dryer doctors. 2
  • 3. © 2015 Kadant Solutions Paper Dryer Doctoring INTRODUCTION 3 DOCTOR BLADE MATERIALS AND APPLICATIONS Doctor blades can be metallic, composite, or plastic. The most common metallic blades are bronze, steel, and Monel. Bronze blades are used to burnish new dryers. Steel blades are used for most intermediate dryer doctor applications. Monel blades are not normally used on paper dry- ers. Composite blades are reinforced with fiber. Most common blade con- structions utilize fiberglass, carbon fiber, a combination of the two, or Kevlar. The resin (i.e., glue) that holds the fibers together is typically a high temperature epoxy. Ceramic and other exotic materials are used for specific applications. When the dryer surface is dirty, it is common to use abrasive blades containing silicon carbide. When there is no fiber reinforcement in the doctor blade, the blade is most commonly referred to as a plastic blade. Because of temperature limitations, plastic blades are not used on paper dryers. From an application perspective, bronze blades are generally used to burnish the surface of new dryers or dryers that have been recently re- ground. These blades wear rapidly on dryers that run at high speed A dryer doctor blade is a cross-machine scraping device that is held in direct contact with the dryer surface. The doctor blade is held in a hold- er that is mounted to a cross machine beam type structure called a doc- tor back. The doctor back is mounted on journals that are supported by self-aligning bearings on the front and back dryer frames. The doctor back pivots on these journals, loading the doctor blade against the out- side surface of the dryer, by gravity, by end-loading cylinders, or by pivoting blade holders (in which case the doctor back should be held firmly in place with turnbuckles). Doctoring systems are designed for specific applications. The applica- tion variables include blade loading, required reliability, roll tempera- ture, sheet shedding needs, cleaning requirements, and expected wear life. When selecting a component or system, the application or duty requirement must be clearly outlined. The penalty for doctor neglect includes roll damage, poor sheet quality, low machine efficiency, high draws, sheet breaks, and damage to doc- tors and adjacent machine clothing. From an application perspective, bronze blades are generally used to burnish the surface of new dryers or dryers that have been recently reground.
  • 4. © 2015 Kadant Solutions Paper Dryer Doctoring 4 and are usually replaced after burnishing. In the past, the replacement blades were steel. Today, it is most common to use composite blades that are designed specifically for continuous operation. Excessive use of bronze blades may lead to build up of bronze deposits on the dryer sur- face, causing runnability and doctoring problems. In high-speed applications, most steel blades will experience increased wear rates and over time will wear the surface of the dryer cylinder. Also, at high speeds steel blades tend to spark, causing a fire hazard. Non-metallic composite blades are often used to minimize the wear of the dryer surface and to reduce the dryer drive load. As a general rule, composite blades do not spark. In recent years, dryer cylinders, espe- cially after-coater dryers and dryers in lead-in positions, have been coated with Tungsten carbide and a surface release coating. The release coatings are often Teflon or silicone based. Composite blades are strongly recommended for these applications. A recent doctor blade development for critical dryer applications is the carbide tipped blade. Carbide tipped bronze blades are used to help clean stickies off dryer cans. Baby dryers and other lead-in dryers are candidates for these blades because stickies have a special affinity for these dryers. Carbide tipped blades are self-sharpening, and carbide at the tip of the blade provides a continuous sharp edge that literally cuts under the stickies and scrapes them off the dryer surface. These blades are also very helpful on critical dryers after a coater section to clean coating color off the dryer surfaces. Another recent innovation is a composite blade with a thermally sprayed carbide tip. This blade does not spark even in severe duty ap- plications. An even more recent doctor blade development used nano materials to further enhance the doctoring performance and doctor blade life. The inclusion of micro particulate materials in the resin matrix provides these enhancements with a highly homogeneous structure. The resin matrix, enhanced with nano materials, is engineered to maintain a strong leading edge for effective and consistent dryer surface doctoring. This results in fewer blade changes, lower operating costs, and efficient surface cleaning. Nanotechnology enhanced blades are applied where the removal of dryer surface contaminants is particularly difficult and where long doctor blade life is required. In high-speed applications, most steel blades will experience increased wear rates and over time will wear the surface of the dryer cylinder.
  • 5. © 2015 Kadant Solutions Paper Dryer Doctoring 5 Doctor blade holders are also designed for specific applications. A rigid holder is generally used for light-duty applications or in positions where the penalty for neglect is not high. Rigid holders are often used in intermediate paper dryer positions. Rigid holders are not recom- mended for sheet shedding (i.e., take-off) positions. Most rigid holders are bolted directly to the doctor back. In order to replace a rigid holder, the doctor back must often be removed from the machine. Recent advancements, however, have made it easier to maintain or change holders should the need arise. Holders that are mounted on T- slide systems are quickly becoming the norm rather than the exception. A Unimate™ doctor blade holder is bolted every three inches into the doctor back. To replace the holder, all the bolts have to be removed. A UniSlide™ doctor blade holder has an interlocking T-slide mounting so the holder can be removed from the doctor back without removing any fastening bolts. Doctor blades are held securely in rigid holders and the blade tips de- flect to fit the profile of the mating rolls. If the blade fit is poor, either due to a bent doctor back, a heavy roll crown, doctor misalignment, a damaged holder, or a worn roll profile, the doctoring efficiency will be poor. Additionally, these rigid holders do not have rotational flexibility in the cross machine direction. Hence, holders that are set up with a small misalignment, off level or off square to the roll, will have difficul- ty in conforming to the roll. All these negative influences generally have an additive effect, so while each issue might be small, there may still be a major roll-to-blade fit problem. Hence, each problem needs to be addressed. Increasing blade loading is not recommended for improving the blade fit, except as a very short-term solution. Increasing loading to achieve a better blade fit results in increased wear of both the doctor blade and the roll surface. More sophisticated blade holders have a self-conforming feature. These holders automatically adjust to match the roll crown or non-uniform roll diameters. These are the “DST” class of holders. These conforming styles of blade holders are held to the doctor back with a series of pivot pins. The doctor back is held in its operating position by a pair of turn- buckles. A cross-machine pneumatic tube is positioned under one end DOCTOR BLADE HOLDERS
  • 6. © 2015 Kadant Solutions Paper Dryer Doctoring 6 of the pivoting holder. When this tube is inflated, it pivots the holder, pressing the blade against the roll surface. These holders are flexible so that the blade loading will be uniform in the cross-machine direction. Conforming holders are often used in critical dryer doctor positions (e.g., first and last dryers). Adjusting the pressure in the tube directly affects the blade pressure. Most conforming holders have two tubes: one to load the blade and the other to unload the blade. The unload tube can be partially pressurized during operation to help seal the in- sides of the holder and keep it clean. A discussion on holders would be incomplete without a brief descrip- tion of what some consider a paradigm shift in holder technology: inte- grating T-Slides into conforming holders to improve their maintenance and repair. This has allowed conforming holders to be used in locations where previously only rigid or direct mount holders had been used. An example of a T-slide mounting is shown below in Figure 1. Fig 1 is a schematic of the Kadant UniSet ™ doctor blade holder. [A] The tube tray can slide out of the machine while the T-bar remains attached to the doctor back. This greatly reduces the time required to service the holder. [B] The pivot rod has continuous contact in the cross direction, providing a tight fit, reducing vibration and improving loading uniformity. [C] The integral top plate is conform- ing and able to reliably shed the sheet in tough applica- tions. C A B
  • 7. © 2015 Kadant Solutions Paper Dryer Doctoring 7 The effectiveness of a conforming blade holder is shown in the follow- ing figure. With a rigid holder, the blade is unable to apply pressure to the shell over a groove in a shell with a 200” face, even though the groove is only 0.010” deep and 40” wide. Eventually, the blade will wear unevenly and into the groove, but this is far from the ideal solu- tion. The DST holder, on the other hand, is able to apply a more uni- form pressure, even on the damaged area of the roll surface. Similarly, a conforming blade holder can accommodate a 0.030” total crown on a press roll, whereas a conventional rigid holder cannot. This is shown in the figure below.
  • 8. © 2015 Kadant Solutions Paper Dryer Doctoring 8 DOCTOR BACKS The doctor back may be a simple angle iron or a more elaborate weld- ed structure. Most doctor backs are either triangular or rectangular in shape, custom-designed for each dryer pocket. The back must meet specific stiffness and deflection criteria, to avoid vibration and chatter. Mounting surfaces are machined on the doctor backs for the blade holders. Doctor backs that are machined for operating below top dry- ers will often be different than the doctor backs that are machined for operating above bottom dryers. This is because of the position of the pivot and the direction of the deflection of the doctor back. It is important, particularly for doctors in top dryer positions, to be able to deal with debris that comes off the roll on the underside of the doctor blade. If a doctor back has a shelf, unwanted debris can collect and create a potential fire hazard and can increase the risk of a doctor jam if the sheet passes under the doctor blade. Modern doctor backs have surfaces that facilitate the fall-off of such debris. Old Design New Design (Patent Pending)
  • 9. © 2015 Kadant Solutions Paper Dryer Doctoring 9 DOCTOR OSCILLATORS Doctor backs are often oscillated using pneumatic or electrical actua- tors. This oscillation helps to cut debris that has collected under the blade and spread out any tendency for the blade to wear narrow bands on the dryer cylinder surface. Oscillating frequencies are quite low, typically only 5 to 15 cycles per minute with a stroke of 12 to 18 mm. Some oscillation strokes can be lower in stroke distance (e.g., 6 mm), but higher in frequency. Electromechanical oscillators have been the workhorse of the industry for many years. In many parts of the world, such as Europe and Asia, they are still regularly used. These oscillators are reliable in operation and are relatively trouble-free. In North America, pneumatic oscillation is preferred for many reasons, including: (1) uninterrupted supply of clean filtered air is economically available for continuous use, (2) oscillation stroke length and frequency can be set per application requirements, and (3) the compact design fits into many locations where real estate is a premium at the end of a doc- tor back (such as between machine frames). Kadant Varimatic™ pneumatic oscillator. Kadant electromechanical oscillator.
  • 10. © 2015 Kadant Solutions Paper Dryer Doctoring 10 DOCTOR BLADE ALIGNMENT In order to achieve consistent and reliable doctor performance, the doc- tor blade must be properly set up, carefully aligned, and correctly fitted to the roll surface. A new blade should be set up to contact the roll sur- face in a line that is parallel to the dryer axis. The journals of the doctor back should then be parallel and level with the dryer axis as well. The blade pressure on the dryer surface should be uniform in the cross- machine direction. The blade angle on dryer doctors is typically set to 25° to 30°. This angle is especially important on sheet shedding positions, where the recom- mended angle is about 28°. Blade angles are easily measured using modern digital gauges as shown in the figure below. The most common device for setting doctor blade angles is the AngleSet™ gauge. This photograph shows the unit being used to take reading on a roll. The compact gauge is handy for taking readings in cramped locations such as secondary positions on double doctors.
  • 11. © 2015 Kadant Solutions Paper Dryer Doctoring 11 DOCTOR BLADE LOAD Typical dryer doctor blade loading is 0.75 pli except for sheet shedding positions, such as the first and last dryers of a dryer section. The sheet shedding doctors are typically loaded 1.5 to 2.5 pli. If the cleaning duty is high, or if the sheet has a tendency to stick to the dryer surface, high- er blade loads and blade angles are recommended. However, when the load is going to be increased, a new blade should be used to prevent the tip of the blade from “bird-mouthing” as shown in the figure below. On a sheet shedding position, it is extremely important to install a new blade before increasing the blade loading, to prevent sheet wrap-ups and damage to the blade, doctor, holder, and machine clothing. DOCTOR BLADE FUNCTIONS Doctor blades can affect sheet quality and production, both positively and negatively. In general, doctors blades are used to keep the outside surfaces of paper dryers clean. The blades are also used to control air flows, assist with tail threading, and prevent sheet wraps and resulting felt damage. Surface cleaning. Uniform build-up on the dryer surfaces can cause a loss in heat transfer; over 5% on those dryers with heavy build-up. Non -uniform build-up can cause local small-scale variations in drying, that result in cockles and puffy paper. The build-up of stickies can cause sheet surface defects, such as fiber picks and linting. To avoid these problems, the dryer surfaces must be kept clean. Contaminated dryer surfaces can also cause the sheet to stick to the dryer surface. Lightweight grades in particular often tend to stick to the
  • 12. © 2015 Kadant Solutions Paper Dryer Doctoring 12 dryer surface and follow it for a short distance, rather than following the tangent path to the next dryer cylinder. This phenomenon, referred to as sheet stealing, can have an adverse effect on sheet runnability. Cleaning the dryer surface can reduce this effect, but the surfaces must be particularly clean to be effective. Chrome plating has been used in the past in an attempt to prevent stickies from forming on the dryer surface. Unfortunately, the chrome plating has not proven to be effective in preventing the build-up of stickies, and carbide tipped blades cannot be used on chrome surfaces without a risk of damage to the surface. Teflon-infused carbide coatings on dryer can surfaces are more effective in reducing the build-up of stickies, and these surfaces can be effectively doctored as well. The cleanliness of the dryer surface can be maintained by continuous doctoring, by periodic loading of the blade (typically during a sheet break or prior to start-ups), or by chemical cleaning during extended shutdowns. Dryer doctors can cause dusting, particularly when running on wet end dryers where there is a lot of fiber picking. The dust and debris that is doctored from the sheet can fall onto the wet paper. If the paper is later coated, this debris can cause coater scratches and sheet breaks. Many coated paper machines will run with the doctor blades unloaded to pre- vent dusting. The dryers are periodically cleaned by loading the doctor blades during sheet breaks and then unloading them after threading the machine. Controlling air flow. When the doctor blade is loaded, or when it is run- ning close to the dryer surface, it tends to reduce the amount of air that is entrained by the moving dryer surface. This can reduce windage and pumping, reducing sheet flutter and sheet disturbances. If the doctor blade is unloaded, however, it is possible for the air velocity to be in- creased, even though the amount of air that is entrained is reduced. Tail threading. On high-speed machines, the location of the blade, the contour of the blade holder, and the shape of the doctor back are often designed to help direct the tail from one dryer to the next. With the as- sistance of edge air nozzles, the tail can in some cases be threaded with- out the use of threading ropes. Sheet wraps. If the sheet follows the dryer after a sheet break, it is called a sheet wrap. The sheet wrap can be blown off the dryers with high- pressure air hoses, provided the sheet is a lightweight grade (such as newsprint) with a limited amount of wrap on the dryer. If the wrap is thick, and in particular if the wrap is a heavy weight board grade, it can take a long time to clear the wrap off the dryer. Oftentimes the dryer section must be stopped, the wrap “speared” off the dryer, and the slab of paper walked slowly down the machine to a section break, where it can be dropped into the basement. In both cases, there is a risk of dam- aging the dryer fabric, either from wads or from the broke poles. The cleanliness of the dryer surface can be maintained by continuous doctoring, by periodic loading of the blade, or by chemical cleaning during extended shutdowns.
  • 13. © 2015 Kadant Solutions Paper Dryer Doctoring Sheet wraps can be prevented by having the dryer doctors loaded when the sheet break occurs. If the blade loading is inadequate, if the blade fit is not tight, or if the blade bevel angle is open at the tip, the sheet can pass under the blade and wrap the dryer. A dryer wrap with a loaded doctor blade can take hours to clear. If the paper is badly jammed be- tween the doctor back and the dryer, it may be necessary to dismount the doctor back and move it away from the surface to provide clearance for removing the broke. The shape of the doctor back can aggravate or minimize the severity of this type of “jam-up.” 13 DRIVE POWER The doctor load on the dryer surface produces a drag that must be overcome by the dryer drive motor. The drive load produced by the dryer doctors depends on the speed of the machine, the width of the dryers, the number of doctor blades that are loaded, the amount of blade load (pli), the blade material, the surface condition of the dryer, and the moisture content of the paper. The affect of each of these varia- bles on the drive load is not well publicized, but general guidelines are available. A typical guideline for drive load is the factor 0.0007 Hp per inch per 100 fpm of speed, for each pli of blade loading. For example, a 350” face dryer that is running 3500 fpm would be expected to add about 4.3 hp to the drive load when the blade is loaded to 0.5 pli: Hp = (0.0007 Hp/inch/100 fpm/pli) x (350 inches) x (3500 fpm) x (0.5 pli) = 4.3 The drive load factor ranges from 0.0006 to 0.0012, with the lower val- ues typical for low-friction synthetic carbon fiber containing blades and the higher values typical for conventional glass blades. The graph on the following page compares the drive power for three types of doctor blades: cotton phenolic (Lamflex™ doctor blade), steel, and a modern low-friction blade material. All three materials are capa- ble of cleaning the dryer surface, but with significantly different friction factors. The Lamflex blade is a cotton phenolic blade, one of the first synthetic laminate blades on the market. A modern low-friction blade, such as SynTek doctor blade, will consume much less drive power than a Lam- flex blade. For example, with an electrical cost of $0.07 / kWh, a 350” wide paper machine running at 4,000 fpm will use (34-12) hp x 0.745 kW/hp x 24 hr/day x 325 operating days/yr x $0.07 / kWh= $8,950 more in electrical costs, per dryer, for a Lamflex blade than for a low- friction blade.
  • 14. © 2015 Kadant Solutions Paper Dryer Doctoring 14 Syntek As noted earlier, dryers with heavy build-up can cause a loss in drying capacity. A typical board or paper dryer with a uniform build-up of 0.01” of paper fiber might lose 2 to 3% of its normal drying capacity. A uniform build-up of 0.05”of fiber might cause a loss in capacity of up to 10 to 15%, on those dryers that have this amount of build-up. Build-up on dryers can consist of various amounts of fiber, starch, size, coating inorganic materials, latex, pitch, hot-melt adhesives (i.e., stick- ies), rust, and other contaminants. The best cure for dryer build-up is prevention. Continuous dryer doctoring can often prevent contamina- tion from becoming a problem. The doctoring system, however, must be tailored to address the type of build-up that is causing the problem. The build up of stickies on the early dryers is rarely uniform and is of- tentimes a problem. It is not uncommon to have "buttons" of stickies on the dryer felts as well as on the dryer surfaces. Stickies cause a loss in runnability (sheet stealing, tear-outs, sheet breaks, poor transfers, lim- ited speed) and sheet defects such as picked fibers, wrinkles, folds, sheet roughness, cockling, and poor moisture profile. Dryer fabric cleaning is just as important as dryer surface cleaning. There are a num- ber of products in the market for dryer fabric cleaning. HEAT TRANSFER
  • 15. © 2015 Kadant Solutions Paper Dryer Doctoring 15 The M-clean™ cleaning system uses high-pressure water in combination with an effective evacuation and air knife system. The water pressure is optimized to ensure opti- mum cleaning, and other factors – such as the final dry- ness of the cleaned surface – can be adjusted individually for each paper machine. It cleans during production without leaving moisture streaks or in any other way negatively affecting the paper quality. No chemicals or other additional ingredients are necessary. In addition, there is no contact with the surface other than from the air and water jets. With respect to dryer surface cleaning, the build up of fibers and inor- ganic materials can be much heavier than stickies and even fairly uni- form. This build-up reduces drying capacity, although steam pressures in early dryers are often reduced anyway, to minimize the picking. A dryer doctor will remove stickies, fiber, and inorganic build-up from dryer surfaces, but this does not necessarily eliminate the tendency for fibers to pick. Even though the dryer surface looks clean, there can still be thin layers of stickie material smeared on the dryer that cause fiber picking and sheet stealing. Recent developments in doctor blade materials have allowed paper mills to clean even heavy build-up from dryers and, with proper blade selection for continuous operation, to keep the dryers clean. Alterna- tives to periodic doctoring are periodic chemical cleaning, continuous chemical passivation of the dryer surfaces, and mechanical cleaning. Mechanical cleaning includes blasting with sand, soda ash, or dry ice. Build-up can also be cleaned off by periodic grinding and by chemical cleaning. Chemical cleaning removes fiber and other surface contami- nants, but it does not restore the dryer surface profile. The dryer surface
  • 16. © 2015 Kadant Solutions Paper Dryer Doctoring 16 profile can be leveled with surface grinding, although this takes an ex- tended downtime, reduces the shell code thickness, and can be quite costly. In some cases, dryer surfaces can be improved by careful use of abrasive cleaning blades, extending the dryer life and possibly avoiding the cost of grinding the surface. It is also possible to reduce the tendency for contaminants to stick to the dryer surface by chemical means. The chemical passivation fluid is ap- plied continuously and directly to either the dryer felt rolls or to the dryer surfaces. The chemicals can be applied with a single traversing nozzle or a series of spraying nozzles mounted to a cross-machine header pipe. These can be costly measures, but justified in severe cases. DRYER DOCTOR BLADE RECOMMENDATIONS Doctor Blade Features Applications DriTek ™ Steel blade 100% steel Ceramic coating Increased tip strength Reliable sheet shedding Heavy duty dryer cylinder cleaning, last top and after-coater dryers, stickies and coating removal DriTek™ Bronze blade 100% bronze Ceramic coating Increased tip strength Minimize sparking Reliable sheet shedding Heavy duty dryer cylinder cleaning, last top and after-coater dryers, stickies and coating removal Nanotechnology Enhanced blades Nanotechnology-enhance resin Cross-machine flexibility Long life No sparking Heavy duty dryer cylinder cleaning, last top and after-coater dryers, stickies and coating removal SynTek™ Plus blade Carbon / glass fiber Performance resin Operating temp 400 F Low friction coefficient Press roll and dryer cleaning, last top and after-coater dryers, stickies and coating re- moval ArmorTek™ blade Metal blade Proprietary coating Low friction coefficient Corrosion resistant Sheet shedding positions/intermediate cans, replaces mild and stainless steel blades Abrasitek™ blade Cleaning / polishing blade kit Abrasive particles on blade 0.250” reverse bevel Yankee dryer surface conditioning, severe dryer contamination, reduce chatter marks, increase time between grinds
  • 17. © 2015 Kadant Solutions Paper Dryer Doctoring 17 Doctoring equipment should be selected after a careful review of the application and duty requirements. This application review should be conducted by a specialist in doctoring technologies, who can pinpoint problem areas and offer the paper maker practical solutions and operat- ing recommendations. For dryers that are particularly difficult to clean, such as lead-in dryers, baby dryers, or the first position where the sheet is first exposed to dry- er heat, a fluid-backed doctor holder and a carbide-tipped blade loaded at about 2 pli is recommended. For last dryer positions, carbide-tipped blades or other carbon contain- ing blades loaded at a minimum of 1.5 pli are recommended. A slide- out feature improves the ease of maintaining or changing the holder in case of damage. Oscillation, in all cases, is recommended. CONCLUSIONS