SlideShare ist ein Scribd-Unternehmen logo
1 von 353
Downloaden Sie, um offline zu lesen
 




                TITAN‐24 DC / IP / MT SURVEY  
                    GEOPHYSICAL REPORT 
                     GETTY PROJECT 
              (BRITISH COLUMBIA, CANADA) 
                      ON BEHALF OF 
       EFFISOLAR ENERGY CORP./GETTY COPPER INC. 
              (BRITISH COLUMBIA, CANADA) 
 




                                                                       
 




                                                                             
QUANTEC GEOSCIENCE LTD                                BENOÎT TOURNERIE, PGEO 
146 SPARKS AVE, TORONTO, ONTARIO, M2H 2S4, CANADA              ARRE VERWEERD 
PHONE: (416) 306‐1941 / FAX: (416) 306‐1949                   JASON METCALFE 
WWW.QUANTECGEOSCIENCE.COM                                        20/07/2011 
QUANTEC GEOSCIENCE LTD 
 


EXECUTIVE SUMMARY 
 

INTRODUCTION 
A  Titan‐24  DC/IP  and  MT  survey  was  conducted  over  the  Getty  Project,  British  Columbia,  Canada  on 
behalf  of  EffiSolar  Energy  Corp.  and  Getty  Copper  Inc.  between  November  20th  and  December  13th  of 
2010. In total 12 lines of data were collected (23.2 line‐km DC/IP and 19.2 km MT) with a station spacing 
of 100 m. The survey geometry for the DC/IP component was a pole‐dipole geometry. The line spacing 
was 250 m and the lines were located in a staggered fashion over three known deposits: Getty North, 
Getty West and Getty South. 

SURVEY OBJECTIVES 
The  objectives  of  this  survey  are  to  further  delineate  the  geophysical  signatures  of  the  Getty  North, 
Getty West and Getty South deposits and identify potential other features of interest. 

RESULTS 
The survey was successful in identifying the Getty North, West and South Deposits. Overall data quality 
was high. Summarizing the results of this survey the following conclusions can be drawn: 
 
    •   Resistivity  distribution  (DC  &  MT)  show  a  succession  of  curved,  sub‐horizontal  conductive  
        features and South‐Southwest‐North‐Northeast faulting trend 
    •   Chargeability signature is fairly weak except for the known deposits and appears to be related to 
        the interpreted faulting.  
    •   Getty North is likely composed of two centers, where the western center extends further north‐
        east in a similar azimuth as the interpreted faults. Resistivity is moderate‐low. 
    •   Getty  West  is  a  near  surface  (<300  m  depth)  feature  of  weak‐moderate  chargeability  & 
        moderate‐low resistivity. 
    •   Getty South is  a low resistivity, weak‐moderate chargeability feature extending to approx. 350 
        m below the surface 
    •   In  total  thirty‐nine  (39)  geophysical  anomalies  were  identified,  of  which  twelve  (12)  are 
        classified  as  high  priority.  Sixteen  (16)  anomalies  fall  in  the  medium  priority  classification  and 
        eleven (11) are labeled as low priority.  A complete overview of all anomalies can be found in 
        the conclusions section, the high priority targets have been listed in the table below. 
 
                                    




                                                          2 
QUANTEC GEOSCIENCE LTD 
 


 
Anomaly    Line    Location    Depth      DC           IP           MT           remarks 
ID                                        signature    signature    signature 
IP‐01      1000  2010‐         90‐350  Mod‐low         Mod‐high                  Getty South/ 
                 2190                                                            Possible fault 
MT‐01      3000  40900‐        290‐       Mod‐low      Mod‐low      low           
                 41820         820 
IP‐04      3250  39390‐        380‐       low          mod          low           
                               630 
                   39600 
IP‐05      3250  39930‐        290‐       low          mod          mod          Correlates with 
                 40120         450                                               bottom of DC‐05 
IP‐07      3250  40290‐        110‐       mod          Mod‐high     Mod‐low      Getty West 
                 40500         270 
IP‐07      3750  40220‐        80‐230  Low‐mod         Low‐mod      Low‐mod      Getty West 
                 40400 
IP‐06      3750  41170‐        290‐       mod          high         low          Getty North 
                 41420         500 
IP‐09      3750  41480‐        80‐420  mod             high         mod          Getty North 
                 41870 
IP‐06      4000  41310‐        90‐380  mod             high         mod          Getty North 
                 41640 
IP‐09      4000  41620‐        0‐210      Mod‐low      high         mod          Getty North 
                 41920 
IP‐06      4250  41540‐        100‐       Mod‐low      Mod‐high     mod           
                 41940         530 
DC‐09      4250  41660‐        200‐       low          Mod‐high     Mod‐low      Correlates with 
                 42000         460                                               bottom of IP‐06 

 
 




                                                  3 
QUANTEC GEOSCIENCE LTD 
 


TABLE OF CONTENTS 
    List of Figures ........................................................................................................................................ 6 
    List of Tables  ......................................................................................................................................... 8 
                  .
    1           Introduction ............................................................................................................................. 9 
           1.1          Survey Objectives ............................................................................................................. 9 
           1.2          General Survey Information ............................................................................................. 9 
    2           Previous work & Geology ....................................................................................................... 13 
           2.1          Getty North .................................................................................................................... 13 
           2.2          Getty South .................................................................................................................... 15 
    3           Results and Interpretation ..................................................................................................... 17 
           3.1          Overview of Inversion Procedure ................................................................................... 17 
                   3.1.1       DC Resistivity & Induced Polarization Inversions ................................................... 17 
                   3.1.2       Audio‐Magnetotelluric Inversions .......................................................................... 18 
           3.2          Discussion of Results ...................................................................................................... 20 
                   3.2.1       Getty South – Line 250N  ........................................................................................ 21 
                                                      .
                   3.2.2       Getty South – Line 500N  ........................................................................................ 22 
                                                      .
                   3.2.3       Getty South – Line 750N  ........................................................................................ 23 
                                                      .
                   3.2.4       Getty South – Line 1000N  ...................................................................................... 24 
                                                       .
                   3.2.5       Getty North – Line 3000N  ...................................................................................... 26 
                                                       .
                   3.2.6       Getty North – Line 3250N  ...................................................................................... 28 
                                                       .
                   3.2.7       Getty North – Line 3500N  ...................................................................................... 30 
                                                       .
                   3.2.8       Getty North – Line 3750N  ...................................................................................... 32 
                                                       .
                   3.2.9       Getty North – Line 4000N  ...................................................................................... 34 
                                                       .
                   3.2.10  Getty North – Line 4250N  ...................................................................................... 36 
                                                   .
                   3.2.11  Getty North – Line 4500N  ...................................................................................... 38 
                                                   .
                   3.2.12  Getty North – Line 5000N  ...................................................................................... 39 
                                                   .
                   3.2.13  Plan map interpretation ......................................................................................... 40 
    4           Conclusions and Recommendations ...................................................................................... 48 
           4.1          Results ............................................................................................................................ 48 
    5           Statement of Qualifications ................................................................................................... 55 
    6           Digital Archive ........................................................................................................................ 58 
    A           Survey Logistics ...................................................................................................................... 59 



                                                                            4 
QUANTEC GEOSCIENCE LTD 
 


    B    Production Summary ............................................................................................................. 71 
    C    DC – IP Pseudo‐Sections of Final Processed Data .................................................................. 75 
    D    MT Soundings Curves of Final Processed Data .................................................................... 123 
    E    MT Pseudo‐Sections of Final Processed Data ...................................................................... 171 
    F    Parallel Sensor Test .............................................................................................................. 179 
    G    Instruments Specifications ................................................................................................... 193 
    H    Geosoft Sections of the 2D Models ..................................................................................... 199 
    I    Geosoft Plan Maps of the 2D Models .................................................................................. 225 
    J    An Introduction to Titan‐24 Direct Current (DC) Resistivity and Induced Polarisation (IP) 
         Methods ............................................................................................................................... 247 
    K    Introduction to the Magnetotelluric Method ...................................................................... 257 
    L    References............................................................................................................................ 263 
    M    Scaled Geosoft Sections and Maps of the 2D Models ......................................................... 265 
 
 
 
 




                                                                   5 
QUANTEC GEOSCIENCE LTD 
 


LIST OF FIGURES 
    Figure 1‐1: General project location. .................................................................................................. 11 
    Figure 1‐2: Claim Map with Titan24 survey Lines. .............................................................................. 11 
    Figure 1‐3: Getty North and South line location map with topography. ............................................ 12 
    Figure 2‐1: Local geology of the Getty North deposit. ........................................................................ 14 
    Figure 2‐2: Local geology of the Getty South Deposit. ....................................................................... 16 
    Figure 3‐1: Example of DC‐IP misfit curves showing relaxation of the model .................................... 18 
    Figure 3‐2: Line 250N – 2D inversion results. ..................................................................................... 21 
    Figure 3‐3: Line 500N – 2D inversion results. ..................................................................................... 22 
    Figure 3‐4: Line 750N – 2D inversion results. ..................................................................................... 23 
    Figure 3‐5: Line 1000N – 2D Inversion results. ................................................................................... 24 
    Figure 3‐6: Line 1000N – 2D Half Space referenced IP model. ........................................................... 25 
    Figure 3‐7: Line 3000N – 2D inversion results. ................................................................................... 26 
    Figure 3‐8: Line 3000N – 2D Half Space referenced IP model. ........................................................... 27 
    Figure 3‐9: Line 3250N – 2D inversion results. ................................................................................... 28 
    Figure 3‐10: Line 3500N – 2D inversion results. ................................................................................. 30 
    Figure 3‐11: Line 3750N – 2D inversion results. ................................................................................. 32 
    Figure 3‐12: Line 3750 N – 2D Half Space referenced IP model. ........................................................ 33 
    Figure 3‐13: Line 4000N – 2D inversion results. ................................................................................. 34 
    Figure 3‐14: Line 4250N – 2D inversion results. ................................................................................. 36 
    Figure 3‐15: Line 4500N – 2D inversion results. ................................................................................. 38 
    Figure 3‐16: Line 5000 N – 2D inversion results. ................................................................................ 39 
    Figure 3‐17: DC model plan map, 1600 m Elevation. .......................................................................... 41 
    Figure 3‐18: IP Model plan map, 1600 m elevation. ........................................................................... 41 
    Figure 3‐19: DC Model plan map, 1400 m elevation. ......................................................................... 42 
    Figure 3‐20: IP Model plan map, 1400 m elevation. ........................................................................... 42 
    Figure 3‐21: DC Model plan map, 1200 m elevation. ......................................................................... 43 
    Figure 3‐22: IP Model plan map, 1200 m elevation. ........................................................................... 43 
    Figure 3‐23: DC model plan map, 1000 m elevation.  ......................................................................... 44 
                                                     .
    Figure 3‐24: IP Model plan map, 1000 m elevation. ........................................................................... 44 
    Figure 3‐25: MT model plan map, 1600 m elevation. ......................................................................... 45 
    Figure 3‐26: MT Model plan map, 1400 m elevation. ......................................................................... 45 
    Figure 3‐27: MT Model plan map, 1000 m elevation. ......................................................................... 46 



                                                                     6 
QUANTEC GEOSCIENCE LTD 
 


    Figure 3‐28: MT Model plan map, 600 m elevation. ........................................................................... 46 
    Figure 4‐1: 2D IP Inversion results (DC model reference) of line 4000N with borehole locations 
         overlay (gold assays in grey, copper assays in green). ................................................................ 48 
    Figure 4‐2: 2D IP Inversion results (DC model reference) of line 750N with borehole locations 
         overlay (copper assays in red). .................................................................................................... 49 
    Figure 4‐3: 2D IP results: 1600 m plan map with borehole locations overlay. ................................... 50 
 
 
 
 
 




                                                                     7 
QUANTEC GEOSCIENCE LTD 
 


LIST OF TABLES 
    Table 1: List of claims surveyed for Getty North and Getty south. ..................................................... 10 
    Table 2: List of Lots surveyed for Getty South. ................................................................................... 10 
    Table 3: Geophysical Targets for the Getty Project. ........................................................................... 53 
 
 
 
 
 




                                                                   8 
QUANTEC GEOSCIENCE LTD 
 


1     INTRODUCTION 
This  report  presents  the  logistics  and  the  results  of  the  analysis  of  the  Titan‐24  DC  ‐  IP  ‐  MT  data 
acquired  from  2010/11/20  to  2010/12/13  over  the  Getty  Project,  on  behalf  of  EffiSolar  Energy 
Corp./Getty Copper Inc.. 
The  first  part  of  this  report  presents  the  inversion  results,  and  their  geophysical  interpretation,  and 
some recommendation for future follow up on the property. 
The second part of the report presents the logistics of the survey, including the survey parameters and 
methodology, and the survey results (data) in digital documents. 

1.1    SURVEY OBJECTIVES 
The exploration objective of the Titan 24 DCIP & MT survey at the Getty Project is to detect porphyry 
mineralization  at  depth  for  drill  targeting  and  structural  delineation.  Titan  24  should  provide  the 
following benefits: 
Verify  the  geophysical  anomalies  identified  by  previous  IP  surveys  to  depth  of  300m  around  two  ore 
deposits. 
And detect further deeper to identify whether there are anomalies under these deposits and showings, 
and if so determine intensity, shape and dimensions. 
The Titan 24 Distributed Acquisition System (DAS; Sheard, 1998) employs a combination of multiplicity 
of  sensors,  24‐bit  digital  sampling,  and  advanced  signal  processing.  It  provides  three  in‐dependent 
datasets  capable  of  measuring  subsurface  resistivity’s  (structure,  alteration  &  lithology)  and 
chargeability (mineralization) to depth. 
The  DC/IP  component  of  the  survey  should  provide  an  excellent  means  of  delineating  target 
mineralization  within  the  top  500m  to  750m  pending  geologic  and  cultural  environment.  The  MT 
resistivity  provides  additional  resistivity  information  from  surface  to  depths  beyond  1km.  The  MT 
resistivity is useful for mapping geological contacts with resistivity contrasts and deep conductors that 
may potentially represent alteration or mineralization. 

1.2    GENERAL SURVEY INFORMATION 
         Quantec Project No.:                          CA00777T 
         Client:                                       EffiSolar Energy Corp./Getty Copper Inc. 
         Client Address                                220‐17 Fawcett Rd 
                                                       Coquitlam, British Columbia, V3K 6V2 
                                                       Canada 
         Client representative:                        William Xu 
                                                       Phone: 604‐555‐0060 
                                                       Email: william@effisolar.com 
         Project Name:                                 Getty Project 
         Survey Type:                                  Titan‐24 DC ‐ IP ‐ MT 
         Project Survey Period:                        2010/11/20 to 2010/12/13 
          



                                                          9 
QUANTEC GEOSCIENCE LTD 
 


              General Location:                                              Approximately 50km South West of Kamloops 
              Province                                                       British Columbia 
              Mining division                                                Kamloops Mining Division 
              District                                                       Logan Lake 
              Nearest Settlement:                                            Logan Lake 
              Datum & Projection:                                            WGS 84, Zone 10U 
              Latitude & Longitude:                                          Approx. 121°01’44”E, 50°33'43”N 
              UTM position:                                                  Approx. 639601m E, 5602996m N 
              List of Claims Surveyed:                                       Getty North & South: see Table 1 1, and Figure 1‐2. 
              List of Lots Surveyed:                                         Getty South see Table 21. 
 
Getty North 
543766               758882                759482              759522    766082         218508      218511      221509       
221561               221562                221563              221564    221565         221566      221567      221568      221569 
221571               221573                221575              221577    221578         221579      221580      221581      221585 
Getty South 
519232               519237                526953                                                                            

                                   Table 1: List of claims surveyed for Getty North and Getty South. 
 
                                                  5483  5601 5604 5607 5611 5614 5617
                                                               5602 5605              5612 5615 5618
                                                               5603 5606              5613 5616  

                                                      Table 2: List of Lots surveyed for Getty South. 
 
                                                           




                                                            
1
      List of Claims (Getty North & South) and Lots (Getty South) provided by Percy F. Cox, rep. Getty Copper Inc. 


                                                                               10 
QUANTEC GEOSCIENCE LTD 
 




                                                                                                            
                                                                                                   2
                                                               Figure 1‐1: General project location . 




                                                                                                                    
                                                                               3
                                                 Figure 1‐2: Claim Map  with Titan24 survey Lines. 
 
                                                            
2
     After Getty Copper Inc. website (www.gettycopper.com/index.php?option=com_content&view=article&id=19&itemid=21). 
3
      Claim Map from MTO system (https://webmaps.gov.bc.ca/imf5/imf.jsp?site=mem_mto_min‐view‐title). 


                                                                                   11 
QUANTEC GEOSCIENCE LTD 
 




                                                                             
    Figure 1‐3: Getty North and South line location map with topography. 
 


                                     12 
QUANTEC GEOSCIENCE LTD 
 


2       PREVIOUS WORK & GEOLOGY 4 
The  Getty  Copper  Project  is  located  in  the  Kamloops  Mining  Division  of  British  Columbia,  Canada  and 
consists  of  both  the  Getty  North  and  Getty  South  Deposits.  The  area  has  historically  produced 
appreciable amounts of copper and molybdenum. To the immediate south of the Getty Copper project 
the Highland Valley open pit mine is operated by Teck Resources Ltd. 
The  property  has  been  explored  intermittently  since  the  1950’s  with  work  consisting  of  surface 
trenching  and  surface  bulk  sampling,  aerial  photographic  surveys  and  base  map  production,  diamond 
and  percussion  drilling,  geological  mapping,  assaying,  IP  and  magnetics  geophysical  surveys,  soil 
geochemical  surveys  and  metallurgical  testing.  To  date,  diamond  drilling  on  the  Getty  North  property 
totals  approximately  46,490  meters  in  210  holes,  and  percussion  drilling  totals  approximately  5724 
meters  in  74  holes.  In  addition,  23  kilometers  of  induced  polarization  surveys,  23  kilometers  of 
geochemical soil sampling surveys, and detailed geological mapping have been conducted. 

2.1        GETTY NORTH  
Getty  North  property  totals  approximately  46,490  meters  in  210  holes,  and  percussion  drilling  totals 
approximately  5724  meters  in  74  holes.  In  addition,  23  kilometers  of  induced  polarization  surveys,  23 
kilometers of geochemical soil sampling surveys, and detailed geological mapping have been conducted. 
The  Getty  North  deposit  is  situated  within  the  upper  Triassic  Guichon  Batholith  which  is  part  of  the 
Nicola Group of the Quesnel Terrane. The Quesnel Terrane is a west‐facing volcanic island‐arc sequence 
that was accreted to the North American plate during the Jurassic age. 
The  Guichon  Batholith,  located  60  kilometers  southwest  of  Kamloops,  is  an  elongated  intrusion  25 
kilometers wide by 40 kilometers long which hosts several large low‐grade porphyry copper deposits. 
The Getty North property is largely underlain by granodiorite cut by a series of porphyry dikes that are 
most likely derived from the Bethlehem phase of the batholith. Porphyry style hypogene mineralization 
within  the  study  area  consists  mostly  of  chalcopyrite  and  lesser  bornite  in  fractures  and  veins,  as 
disseminations,  and  in  breccia  bodies.  Oxidized  mineralization  is  also  present  near  the  Kamloops 
unconformity.  
Fractures  and  faults  are  prominent,  and  the  areas  of  highest  fracture  density  are  also  the  zones  of 
higher‐grade  mineralization.  The  areas  of  higher  fracture  density  are  adjacent  to  the  stock  and 
associated with sets of steeply dipping north and northeast trending faults that have dominantly formed 
post‐mineralization.  Kamloops  Group  rocks  are  restricted  almost  entirely  to  down‐faulted  blocks  and 
associated vertical offsets that have been identified by drilling. 
 




                                                            
4
   After “National Instrument 43‐101 ‐ Preliminary Feasibility Study Technical Report of the Getty Copper Project” West Coast 
Environmental and Engineering, 2009. 


                                                                         13 
QUANTEC GEOSCIENCE LTD 
 




                                                              
    Figure 2‐1: Local geology of the Getty North deposit. 
           




                             14 
QUANTEC GEOSCIENCE LTD 
 


2.2    GETTY SOUTH 
As with the Getty North Deposit, the Getty South property has been explored intermittently since the 
1950’s  with  work  consisting  of  surface  trenching  and  surface  and  underground  bulk  sampling, 
underground workings, aerial photographic surveys and base map production, diamond and percussion 
drilling,  geological  mapping,  assaying,  IP  and  magnetics  geophysical  surveys,  soil  geochemical  surveys 
and  metallurgical  testing.  The  Getty  South  property  has  been  examined  with  almost  4000  meters  of 
surface trenching, approximately 20,353 meters of diamond drilling from surface and underground sites, 
and  1,719  meters  of  underground  workings.  Most  recently,  an  exploration  program  composed  of  13 
reconnaissance  diamond  drill  holes  and  15  surface  trenches  with  a  total  length  of  1,572  meters  were 
completed in 1996 and 1997. 
The  Getty  South  deposit  is  also  situated  within  the  upper  Triassic  Guichon  Batholith.  The  deposit  is  a 
composite  breccia  zone  of  what  was  originally  Guichon  quartz  diorite  that  was  intruded  by  andesite, 
rhyolite and porphyritic dikes and related phreato‐magmatic breccias.  
The Getty South deposit is located immediately west of a regional north‐south striking structure locally 
called the Jersey Fault. A similar parallel‐striking fault, termed the Bethlehem Fault by previous authors, 
is located near the east side of the breccia.  
 




                                                         15 
QUANTEC GEOSCIENCE LTD 
 




                                                              
    Figure 2‐2: Local geology of the Getty South Deposit. 
 
 




                             16 
QUANTEC GEOSCIENCE LTD 
 


3     RESULTS AND INTERPRETATION 
In  this  section,  results  of  the  2D  inversion  of  the  Titan‐24  data  are  presented  as  cross‐sections  along 
each survey line. The observed anomalies are described and discussed as potential drilling targets.  
The  Titan‐24  system  acquires  three  types  of  geophysical  data  –  magnetotelluric  (MT),  direct  current 
resistivity (DC), and induced polarization (IP). The MT and DC method are used to resolve the resistivity 
distribution  of  the  subsurface  by  measuring  the  electric  potential  (DC)  and  the  variation  of  natural 
source electric and magnetic fields (MT). Resistivity can be an indicator of metallic mineralization, but is 
more often than not controlled by rock porosity and is therefore an indirect indicator of alteration and 
mineral grain fabric.  
In  the  induced  polarization  method,  electrical  capacitance  or  chargeability  of  the  subsurface  is 
measured. Chargeability is a near‐direct indicator of the presence of mineralization, in both massive and 
disseminated  forms.  This  mineralization  is  most  commonly  various  sulphides  and  graphite,  but  also 
includes clay‐type minerals potentially making it a useful tool for base‐metals exploration.  
Detail  results,  i.e.  observed  DC‐IP‐MT  data  and  equivalent  calculated  responses  for  each  model,  are 
presented  on  a  line  per  line  basis  in  PowerPoint  (PDF)  documents  delivered  in  the  digital  archive 
(CD/DVD) attached to this report. 

3.1     OVERVIEW OF INVERSION PROCEDURE 

3.1.1    DC RESISTIVITY & INDUCED POLARIZATION INVERSIONS 
DC‐IP is an electrical method that uses the injection of current and the measurement of voltage along 
with  its  rate  of  decay  to  determine  the  subsurface  resistivity  and  chargeability,  respectively.  Depth  of 
investigation is mainly controlled by the array geometry, but also the transmitted current, in terms of 
signal to noise, particularly for the chargeability. In its standard configuration (a=100m / n=0.5‐23.5) the 
Titan‐24 surveys typically image DC resistivity to depths of 500‐750m, and the IP typically images to 500‐
750m, in sub‐vertical tabular geologic settings and up to 50% more for sub‐horizontal. The differences in 
penetration are a function of the relative property contrasts and relative signal‐to‐noise levels between 
the  two  measurements.  However  this  investigation  depth  increases  proportionally  to  the  dipole‐size 
(i.e., 1000‐1500m for 200m dipoles). A detailed introduction to DC‐IP is given in Telford, et al. (1976). 
The primary tool for evaluating the Titan‐24 data is through the inversion of the data in two‐dimensions 
(2D). An inversion model depends not only on the data collected, but also on the associated data errors 
in the reading and the “model norm”. Inversion models are not unique and may contain “artefacts” from 
the inversion process. The inversion model may not accurately reflect all of the information apparent in 
the actual data. Inversion models must be reviewed in context with the observed data, model fit, and 
with an understanding of the model norm used. 
The Titan‐24 DC and IP data were inverted to produce cross‐sections of the resistivity and chargeability 
variations along the survey lines. The UBC DCIP2D inversion code (Oldenburg & Li, 1994) was used for 
the 2D inversion of the DC and IP data. 
Potential  difference  (voltage)  and  phase  values  were  used  as  input  data  in  the  DC  and  IP  inversions, 
respectively. DC Resistivity and induced polarization (IP) data are first pre‐conditioned; the error of each 
data point is adjusted for the inversion process using a general error equation similar to: 




                                                          17 
QUANTEC GEOSCIENCE LTD 
 


                                                ⎛Vp ⎞    Vp                ⎛Vp ⎞
                                          errors⎜ ⎟ = A%
                                                ⎜ IP ⎟      + B × Acq_Error⎜ ⎟ + C (floor) 
                                                                           ⎜ IP ⎟
                                                ⎝ ⎠      IP                ⎝ ⎠
with the set of parameters  {A, B , C }  adjusted (and large errors data points removed) for each dataset 
until we achieve  convergence with relaxation of the DC or IP  models  (see example of  Model Norm fit 
curve on Error! Reference source not found.). 




                                                                                                                       
                          Figure 3‐1: Example of DC‐IP misfit curves showing relaxation of the model 
Three 2D inversions were carried out along each line.  
The DC data was inverted using an unconstrained 2D inversion with a homogenous half‐space of average 
input data as starting model. The DC models are labelled as ‘DC’. 
Two  IP  inversions  are  calculated  from  the  same  data  set  and  parameters,  but  they  use  a  different 
reference  model 5.  The  first  inversion  of  the  IP  data  uses  the  previously  calculated  DC  model  as  the 
reference model, and is labelled the ‘IP dcref model’. The second IP inversion uses a homogeneous half‐
space resistivity model as the reference model and is labelled ‘IP hsref model’ or ‘IP nullcon’ model. This 
model is included to test the validity of chargeability anomalies, and to limit the possibility of inversion 
artefacts in the IP model due to the use of the DC model as a reference. 
The DC and IP inversion use the same mesh. The horizontal mesh was set as 3 cells between electrodes 
on each line. The vertical mesh was designed with a cell thickness from 10 to 15m for the first 200‐300m 
to accommodate the topographic variation along the profile, and then it increases from 20 to 100m with 
depth. The inversions were generally run for a maximum of 50 iterations. 
 

3.1.2         AUDIO‐MAGNETOTELLURIC INVERSIONS  
The  Audio‐Magnetotelluric  (AMT)  method  is  a  natural  source  method  that  measures  the  variation  of 
both  the  electric  (E)  and  magnetic  (H)  field  on  the  surface  of  the  earth  in  order  to  determine  the 
distribution  at  depth  of  the  resistivity  of  the  underlying  rocks.  A  complete  review  of  the  method  is 
presented in Vozoff (1972) and Orange (1989). 
                                                            
5
      The reference model is used to calculate the sensitivity matrix used at each iteration for the IP inversion. 


                                                                         18 
QUANTEC GEOSCIENCE LTD 
 


The measured MT impedance Z, defined by the ratio between the E and H fields, is a tensor of complex 
numbers. This tensor is generally represented by its two off‐diagonal elements. In a 1D earth model, i.e. 
the resistivity varies only with depth, there is no strike direction and the two off‐diagonal impedances 
are equal. In the 2D case, i.e. when the resistivity varies with depth and perpendicularly to the strike, 
and when the profile is set perpendicular to the strike direction, the two off‐diagonal elements are not 
equal  but  reflect  the  variation  of  the  resistivity  along  two  directions,  one  parallel  and  the  other 
perpendicular  to  the  strike,  i.e.,  the  TE  (Transverse  Electric;  E  parallel  to  the  strike)  and  the  TM 
(Transverse Magnetic; E perpendicular to the strike) modes.  
Both TE and TM impedances are represented by an apparent resistivity (a parameter proportional to the 
modulus of Z) and a phase (argument of Z). The variation of those parameters with frequency relates the 
variations  of  the  resistivity  with  depth,  the  high  frequencies  sampling  the  sub‐surface  and  the  low 
frequencies  the  deeper  part  of  the  earth.  However  the  apparent  resistivity  and  the  phase  have  an 
opposite behaviour. An increase of the phase indicates a more conductive zone than the host rocks, and 
is associated with a decrease of the apparent resistivity. The objective of the inversion of MT data is to 
compute a distribution of the resistivity of the surface that explains the variations of the MT parameters, 
i.e.  the  response  of  the  model  that  fits  the  observed  data.  The  solution  however  is  not  unique  and 
different  inversions  must  be  performed  (different  programs,  different  conditions)  in  order  to  test  and 
compare solutions for artefacts versus a target anomaly. 
The depth of investigation is determined primarily by the frequency content of the measurement. Depth 
estimates  from  any  individual  sounding  may  easily  exceed  20  km.  However,  the  data  can  only  be 
confidently interpreted when the aperture of the array is comparable to the depth of investigation. In 
the  instance  of  Titan  24  surveys,  inversion  depth  is  generally  limited  to  about  half  the  length  of  the 
survey line or profile. 
The primary tool for evaluating the Titan MT data is 2D inversion. The inversion model is dependent on 
the  data,  but  also  on  the  associated  data  errors,  and  the  model  norm.  The  inversion  models  are  not 
unique, may contain artefacts of the inversion process, and may not therefore accurately reflect all of 
the  information  apparent  in  the  actual  data.  Inversion  models  need  to  be  reviewed  in  context  of  the 
observed  data,  model  fit,  an  understanding  of  the  model  norm  used  and  if  the  model  is  geologically 
plausible. 
For  this  study,  2D  inversions  were  performed  using  the  unrotated  data,  which  assumes  the  strike 
direction is perpendicular to the profile for all sites: the TM mode is then defined by the inline E‐field 
(and cross line H‐field), and the TE mode is defined by the cross line E‐field (and inline H‐field) data. 
The  MT models were  calculated with the  RLM code (Rodi and  Mackie, 2001)  and with  the PWm  code 
(development Quantec Geoscience; based on deLugao and Wannamaker, 1996).  
The  inversions  use  the  TE  and  TM  resistivity  and  phase  from  10kHz  to  0.1Hz,  interpolated  at  4  to  6 
frequencies per decade, and assume 5% error for the resistivity and 3 degrees error for the phase. 
One RLM inversion model (mu_h4) was derived from inverting the TE and TM apparent resistivity and 
phase MT data starting from a half space model of 100 Ohm‐m. A second RLM model (mu_d4) also used 
the TE and TM phase and rho data but as a starting model a stitched 1D determinant model was used.  
The  same  set  of  inversions  models  was  also  calculated  using  the  PWm  code  (pu_h4  starting  from  the 
half space model and pu_d4 starting from the 1D determinant).  
The  final  2D  inversion  MT  model  presented  in  this  report,  and  used  in  the  interpretation  is  the  RLM 
inversion starting from the stitched 1D determinant model, and using TM and TE apparent resistivity and 
phase from 10kHz to 0.1Hz, because of its fit to the data and its correlation with the DC and IP models. 


                                                          19 
QUANTEC GEOSCIENCE LTD 
 


3.2    DISCUSSION OF RESULTS 
In the following section the resulting DC resistivity, MT resistivity and IP chargeability models, obtained 
after inversion of the acquired data will be described. The first part of the discussion will consist of a line 
by line description; the second part will deal with plan maps constructed from the 2D inversion results. 
On each line anomalies and features of interest will be indicated. The features will be picked based on 
the  correlation  between  resistivity  and  chargeability  signatures,  size  and  depth  below  the  surface.  A 
table of the results can be found in the conclusion section of this report (Table 3). 
For the first set of lines (250N ‐ 1000N) no MT survey was conducted, therefore only the DC model (top 
image) and the DC referenced IP model (bottom image) will be shown. From line 3000N onwards the MT 
model will  be shown below the IP  model. For selected lines the IP model  calculated with a half space 
resistivity model as a reference (HS‐referenced) will also be shown. All models calculated can be found 
in the appendices of the report. Many of the northern group of lines have been surveyed with current 
extensions,  which  are  indicated  with  the  station  symbol  (inverted  triangle)  on  the  DC  and  IP  section 
maps. 
The  colour  bars  used  in  all  section  and  plan  maps  will  be  consistent  in  the  report.  In  the  DC  and  MT 
resistivity  models  values  of  10  Ohm‐m  correspond  to  the  purple/red  colours  (conductive)  and  10.000 
Ohm‐m to white (resistive), in a logarithmic colour scale. For both the dc referenced IP chargeability as 
well  as  the  half  space  chargeability  models  a  linear  colour  scale  is  used,  where  the  cool  colour 
correspond to 0 mrad, and the warm colours to 25 mrads. 
 




                                                                            
 
                                      




                                                          20 
QUANTEC GEOSCIENCE LTD 
 


3.2.1   GETTY SOUTH – LINE 250N 




                                                                                                               
                                Figure 3‐2: Line 250N – 2D inversion results. 
Line 250N is the furthest south line covering the Getty South deposit, and is the first line acquired in this 
project. The resistivity model shows a conductive overburden with an average thickness of 50 meter. In 
the center of the line it appears the thickness of the conductive overburden increases to approximately 
100  m.  Two  conductive  features  are  identified  on  this  line,  anomaly  DC‐01  on  the  western  side,  and 
anomaly DC‐02 on the eastern side.  
Anomaly DC‐01 is an east dipping feature, 150‐200 m thick, and could be connected to the surface. It is 
located within a large weak‐moderately chargeable zone, which likely has a formational nature. Within 
this  broad  chargeability  feature  a  center  of  moderate  chargeability  values  is  observed  (IP‐01), 
correlating with the location of DC‐01 but with an apparent different dip.  
The second conductor on the line (DC‐02) is located close to the surface, and extends only to depths of 
approximately  200  meter  below  the  surface.  Anomaly  DC‐02  is  located  in  a  region  without  any 
chargeability signature. 
                                    




                                                       21 
QUANTEC GEOSCIENCE LTD 
 


3.2.2   GETTY SOUTH – LINE 500N 




                                                                                                                 
                                 Figure 3‐3: Line 500N – 2D inversion results. 
The second line of the survey is located 250 meter  further  north, and parallel to line 250N. Again  the 
resistivity model shows a conductive overburden with an average thickness of approximately 50 m, but 
locally  extending  to  100  meter  below  the  surface.  The  deeper  part  of  the  resistivity  model  shows  a 
moderate  resistivity  without  many  features.  At  depth  between  250  and  300m,  a  more  conductive 
feature is observed (DC‐03); it is located in a region of low chargeability. A single chargeability anomaly 
is  observed  on  line  500N  (IP‐01).  The  anomaly  IP‐01  is  located  just  below  the  conductive  overburden 
and  extends  to  a  depth  of  approximately  400  m  below  the  surface.  It  has  a  moderate‐strong 
chargeability  signature,  and  it  is  sharply  bound  on  the  eastern  side.  It  seems  to  correlate  with  the 
moderate chargeability anomaly observed on Line 250N (IP‐01). 
                                    




                                                        22 
QUANTEC GEOSCIENCE LTD 
 


3.2.3   GETTY SOUTH – LINE 750N 




                                                                                                       
                              Figure 3‐4: Line 750N – 2D inversion results. 
Chargeability anomaly IP‐01 can also be observed on line 750N, although its signature is reduced to a 
moderate chargeability feature. Anomaly IP‐01 is sharply bound to the east  and west on  this line, the 
western boundary is a narrow conductive, near vertical feature. This feature has the resistivity signature 
of a fault, and is identified as such on the section.  
A second moderate (smaller) chargeability feature IP‐02 is observed on this line. This anomaly is located 
below the conductive overburden and separated from IP‐01 by a small conductive feature (DC‐04). Also 
present on this line is anomaly DC‐03, in the eastern part of the line and appears to have moved closer 
towards the surface. 
                                 




                                                   23 
QUANTEC GEOSCIENCE LTD 
 


3.2.4   GETTY SOUTH – LINE 1000N 




                                                                                                              
                               Figure 3‐5: Line 1000N – 2D Inversion results. 
The upwards trend of anomaly  DC‐03  can also be observed on the final line  covering  the  Getty  South 
deposit, where DC‐03 is located just below the overburden, and has a very conductive signature. 
Also  anomalies  IP‐01  and  IP‐02  are  observed  on  this  line  again,  although  IP‐01  has  a  much  smaller 
signature  when  compared  to  the  previous  lines.  Both  features  are  again  separated  by  a  conductive 
anomaly,  which  could  be  related  to  DC‐04.  Anomaly  IP‐01  is  again  bound  on  its  western  side  by  an 
interpreted fault, although the geometry of the survey does not allow a very deep interpretation at this 
part of the line. The chargeability anomalies identified on this line are very well represented in the Half 
Space referenced IP model presented in Figure 3‐6. 
 




                                                       24 
QUANTEC GEOSCIENCE LTD 
 




                                                                    
    Figure 3‐6: Line 1000N – 2D Half Space referenced IP model. 
 
               




                                25 
QUANTEC GEOSCIENCE LTD 
 


3.2.5   GETTY NORTH – LINE 3000N 




                                                                              
                           Figure 3‐7: Line 3000N – 2D inversion results. 
                               




                                                26 
QUANTEC GEOSCIENCE LTD 
 


Line  3000N  is  the  first  full  length  2.4  km  Titan‐24  setup,  and  the  first  line  where  DC/IP  and  MT  was 
acquired. Both DC and MT resistivity show a sub horizontal layered response for the eastern side of the 
line. At least two conductive bands can be identified; the top one is located approximately 150 m below 
the surface, and the bottom one between 300 and 350 meters below the surface. These two features 
curved  towards  the  surface  in  the  middle  of  the  line,  and  abruptly  terminate.  This  geometry  is  also 
observed in the chargeability model with a clear split in the two large zones of moderate chargeability. A 
steeply  dipping  fault  has  been  interpreted  at  the  center  of  the  line,  lining  up  with  several  smaller 
conductive features in the DC and MT model. In the western side of the line a similar feature is observed 
in the MT model, which is also indicated in the model, this feature is too deep to be confirmed by the DC 
resistivity model.  
The two regions of chargeability are likely formational in origin, with some isolated centers of increased 
chargeability.  The  western  half  shows  anomalies  IP‐04  and  IP‐05,  both  located  in  between  two 
conductive features in the DC model. The top feature is labelled DC‐05 and has some signature in the 
MT model as well. The bottom conductor in the DC model could not be confirmed by the MT model, and 
therefore has to be interpreted with great care. Anomaly IP‐04 could be a representation of the Getty 
West anomaly.  
On the eastern side of the line, anomaly IP‐06 is observed; it is located in between the sub horizontal 
conductive  bands  and  a  deep  broken‐up  MT  conductor  (MT‐01);  it  is  likely  the  signature  of  this 
conductive  anomaly  is  not  well  resolved  in  the  DC  model  due  to  its  depth.  However,  the  MT  feature 
does correlate with a large moderate conductor in the DC model.  
Anomalies IP‐04 and IP‐05 correlate well between the DC referenced and the HS referenced IP models 
(Figure  3‐8).  Anomaly  IP‐03  on  the  other  hand  has  a  good  lateral  correlation,  but  could  be  located 
slightly deeper than indicated in the DC referenced model. 
 




                                                                                                                        
                         Figure 3‐8: Line 3000N – 2D Half Space referenced IP model. 
 
                                     




                                                          27 
QUANTEC GEOSCIENCE LTD 
 


3.2.6   GETTY NORTH – LINE 3250N 




                                                                              
                           Figure 3‐9: Line 3250N – 2D inversion results. 
                               




                                                28 
QUANTEC GEOSCIENCE LTD 
 


Line 3250N is not only 250 m to the north but its starting point is also shifted 750 m to the west when 
compared to Line 3000N. It does show a similar sub horizontal pattern, especially the MT model. The IP 
model shows at least two non‐chargeable breaks in the large, likely formational, moderate chargeable 
feature.  On  the  western  side  of  the  model,  anomaly  IP‐05  is  located  at  depth;  it  has  a  moderate 
chargeability  signature  and  is  located  in  a  conductor  in  both  the  DC  and  MT  models.  It  could  be 
associated  to  the  interpreted  fault  directly  to  the  east  of  IP‐05.  On  the  other  side  of  this  interpreted 
fault, the anomaly DC‐06 and the small chargeability anomaly IP‐03 are observed; both are part of one 
of  the  sub‐horizontal  features  in  the  MT  model.  In  the  center  of  the  line  moderate‐high  chargeability 
anomaly  IP‐04  corresponds  closely  to  the  known  location  of  the  Getty  West  deposit.  The  features  is 
located in between  two of the sub‐horizontal feature, and bound on the east  by a narrow conductive 
feature  in  the  DC  model,  which  likely  is  another  fault,  but  could  not  be  confirmed  by  the  MT  model. 
Approximately 250 m east and at a greater depth (480 m below the surface) a small center of increased 
chargeability  (IP‐06)  is  observed  with  a  similar  signature  as  IP‐05  with  relation  to  the  deep  horizontal 
feature in the MT model. Again it appears this chargeability anomaly appears to be bound in the east 
with a fault, as observed in the MT model (the depth of the fault is too great for the DC model to image 
these types of features correctly).  
 
                                      




                                                           29 
QUANTEC GEOSCIENCE LTD 
 


3.2.7   GETTY NORTH – LINE 3500N 




                                                                               
                           Figure 3‐10: Line 3500N – 2D inversion results. 
                               




                                                30 
QUANTEC GEOSCIENCE LTD 
 


Line  3500N  has  shifted  900  m  to  the  east  relative  to  line  3250N.  Anomaly  IP‐04  associated  with  the 
Getty West deposit is now located at the far western side of the model. It has grown slightly in size, but 
its  location  has  not  changed  significantly.  Again  a  steeply  dipping  fault  is  identified,  based  on  the  non 
chargeable  break  in  the  moderate  formational  chargeability  feature  below  the  non  chargeable, 
conductive  overburden.  Also,  the  curved  and  sub  horizontal  features  are  observed  on  this  line.  The 
upper feature in which anomaly IP‐04 is located has a more restive nature. The lower feature has a more 
conductive nature, especially in the DC model.  
Under the eastern half of the line, two major chargeability anomalies IP‐07 and IP‐08 can be observed. 
The  location  of  these  features  correlates  very  well  with  the  Getty  North  deposit  which  geophysical 
signature  appears  to  be  split  into  two  centers.  The  largest  IP  anomaly  IP‐07  is  located  at  a  depth  of 
approximately  300  m  below  the  surface;  the  second  IP  anomaly  IP‐08  is  identified  at  a  more  shallow 
depth,  approximately  175  m  below  the  surface.  Both  anomalies  correlate  very  well  with  a  conductive 
band in the MT model which , and appear to be split in the DC model by a conductive feature below the 
chargeability anomalies (this was also observed on line 750N and 1000N with anomaly DC‐04 separating 
anomalies IP‐01 and IP‐02 of the Getty South deposit).  
 
                                      




                                                           31 
QUANTEC GEOSCIENCE LTD 
 


3.2.8   GETTY NORTH – LINE 3750N 




                                                                               
                           Figure 3‐11: Line 3750N – 2D inversion results. 
 
                               




                                                 32 
QUANTEC GEOSCIENCE LTD 
 


Line  3750  is  shifted  200  m  towards  the  west  from  line  3500N.  It  shows  the  grouped  anomalies 
associated  with  Getty  North  (IP‐07  and  IP‐08)  on  the  eastern  side  of  the  line.  The  signature  of  both 
anomalies is the largest on this line of the survey area. Anomaly IP‐08 has very high chargeability values 
and  is  located  very  close  to  the  surface,  identifying  it  as  the  main  geophysical  target  of  this  survey. 
Anomaly IP‐07 also has high chargeability values, but is smaller in size and located at greater depth (270 
m  below  the  surface,  in  comparison  to  the  70  m  depth  of  IP‐08  on  this  line).  Again  both  anomalies 
appear to be split by a conductive feature in the DC model, located in the middle of the anomalies.  
The  DC  and  MT  resistivity  models  show  the  steeply  dipping  faults  and  the  sub‐horizontal,  curved 
features.  Both  interpreted  faults  also  are  bounding  features  of  two  weak‐moderate  chargeability 
anomalies (IP‐09 and IP‐10). Anomaly IP‐10 could be related to the curved conductor as well as to the 
interpreted  fault,  whereas  IP‐09  seems  to  be  associated  with  the  interpreted  fault  only.  The  upper 
conductive  band  shows  a  very  small  response  of  the  Getty  West  deposit  (IP‐04).  There  is  a  very  good 
correlation between the DC reference IP model and the half space referenced IP model (Figure 3‐12). 
 




                                                                                                                  
                        Figure 3‐12: Line 3750 N – 2D Half Space referenced IP model. 
 
                                      




                                                          33 
QUANTEC GEOSCIENCE LTD 
 


3.2.9   GETTY NORTH – LINE 4000N 




                                                                               
                           Figure 3‐13: Line 4000N – 2D inversion results. 
 
                               




                                                 34 
QUANTEC GEOSCIENCE LTD 
 


Line 4000N is centered on the Getty North deposit (IP‐07, IP‐08). Its location is shifted by 500 m towards 
the  east  when  compared  to  line  3750N.  This  group  of  anomalies  has  a  very  strong  expression  on  this 
line, although the size of both IP‐07 and IP‐08 has reduced. It appears that IP‐08 is a surface feature on 
this line, which should be visible in the surface geology. Also IP‐07 is located at a very shallow depth (80 
m  below  the  surface).  The  dividing  conductor  observed  in  the  previous  lines  does  not  have  a  clear 
signature  on  line  4000N,  but  the  contour  lines  of  the  DC  model  do  suggest  slightly  more  conductive 
features in between both anomalies.  
The curved, sub horizontal features as the faults are not clearly represented in the models of this line, 
likely because of the overall conductive response of the model. A near surface conductor is located in 
both the DC and MT models in the eastern edge of the profile. However, it doesn’t have a chargeability 
signature, but could be easily tested by geological mapping. 
 
                                    




                                                        35 
QUANTEC GEOSCIENCE LTD 
 


3.2.10 GETTY NORTH – LINE 4250N 




                                                                              
                          Figure 3‐14: Line 4250N – 2D inversion results. 
 

                              




                                                36 
QUANTEC GEOSCIENCE LTD 
 


Line  4250N  has  a  similar  extent  to  Line  3750  (i.e.  500  m  further  west  than  line  4000N).  It  shows  only 
west side of the Getty North anomalies (IP‐07). It is possible that IP‐09 is observed at this northing as 
well, but that part of the line was only covered by current extensions, and no receiving dipoles. 
The  conductive  anomaly  DC‐09,  as  the  separating  feature  between  anomalies  IP‐07  and  IP‐08,  is  very 
prominent on this line. It also has an expression in the MT model.  
A new large chargeable feature IP‐11 is observed on the western side of the line. Its depth below the 
surface  makes  it  difficult  to  show  much  detail  for  both  method  and  inversion  algorithm.  However,  its 
close  correlation  to  conductive  features  in  the  DC  and  MT  models  do  point  to  an  interesting  target. 
Unfortunately due to the staggered line location, there is no nearby line to confirm this anomaly, and it 
therefore has to be treated with care. 
 
                                      




                                                          37 
QUANTEC GEOSCIENCE LTD 
 


3.2.11 GETTY NORTH – LINE 4500N 




                                                                                                                    
                               Figure 3‐15: Line 4500N – 2D inversion results. 
The location of line 4500N involved another shift of 950 meter towards the east, leaving anomaly IP‐07 
on  the  eastern  side  of  the  model.  This  feature,  closely  associated  with  the  Getty  North  deposit,  is 
located at a depth around 300 m below the surface on the line, and is the only chargeable feature on 
the  line.  Anomaly  IP‐07  appears  to  be  a  chargeable  centre  of  a  large  low‐moderate  formational 
chargeability feature, bound on either side by interpreted faults. 
                                    




                                                        38 
QUANTEC GEOSCIENCE LTD 
 


3.2.12 GETTY NORTH – LINE 5000N 




                                                                                                                          
                                 Figure 3‐16: Line 5000 N – 2D inversion results. 
The last line of the survey is Line 5000N, located 500 m north of line 4500N and shifted 250 m to the 
west.  No  chargeability  anomalies  are  observed  on  this  line,  apart  from  the  large  formational  feature 
bound by the two interpreted faults. Two MT conductors are located on this line (MT‐02 and MT‐03), 
which have to be interpreted with care, the depth of these anomalies should implicate a response on 
the  DC  model  as  well.  But  this  is  not  the  case.  Additional  lines  to  either  the  north  or  the  south  are 
needed to test these features. 



                                                           39 
QUANTEC GEOSCIENCE LTD 
 


3.2.13 PLAN MAP INTERPRETATION 
Correlation  of  anomalies  from  line  to  line  can  be  achieved  by  extraction  of  plan  maps  from  the 
calculated  section  models.  In  this  fashion  model  values  are  taken  at  a  given  elevation  level  and  the 
values are used to create a gridded plan map.  
In this report, four elevation levels (1600 m elevation, 1400 m, 1200 m and 1000 m) will be discussed. 
Other elevation levels will be presented in the appendix of this report.  
The gridding parameters and colour bar legends used in creation of the section maps will be the same 
for the plan maps. Also the same annotation for anomalies and geological interpretation will be used. 
 
 
 




                                                        40 
QUANTEC GEOSCIENCE LTD 
 




                                                                                                                                         
    Figure 3‐17: DC model plan map, 1600 m Elevation.                              Figure 3‐18: IP Model plan map, 1600 m elevation. 
                                                                           
                                                                                    




                                                                    41 
QUANTEC GEOSCIENCE LTD 
 




                                                                                                                                         
    Figure 3‐19: DC Model plan map, 1400 m elevation.                              Figure 3‐20: IP Model plan map, 1400 m elevation. 
                                                                           
                                                                                    




                                                                    42 
QUANTEC GEOSCIENCE LTD 
 




                                                                                                                                         
    Figure 3‐21: DC Model plan map, 1200 m elevation.                              Figure 3‐22: IP Model plan map, 1200 m elevation. 
                                                                           
                                                                                    




                                                                    43 
QUANTEC GEOSCIENCE LTD 
 




                                                                                                                                         
    Figure 3‐23: DC model plan map, 1000 m elevation.                              Figure 3‐24: IP Model plan map, 1000 m elevation. 
                                                                           
                                                                           




                                                                    44 
QUANTEC GEOSCIENCE LTD 
 


 




                                                          
    Figure 3‐25: MT model plan map, 1600 m elevation. 
 
 




                                                          
    Figure 3‐26: MT Model plan map, 1400 m elevation. 
 
          




                           45 
QUANTEC GEOSCIENCE LTD 
 


 




                                                          
    Figure 3‐27: MT Model plan map, 1000 m elevation. 
 
 




                                                          
    Figure 3‐28: MT Model plan map, 600 m elevation. 
 
          




                           46 
QUANTEC GEOSCIENCE LTD 
 


The circular nature of the Getty North deposit (as depicted in Figure 2‐1) becomes very clear in the 1600 
m  plan  maps  (Figure  3‐17,Figure  3‐18  and  Figure  3‐25),  where  anomalies  IP‐07  and  IP‐08  are  merged 
into one single chargeability high with two distinct centres. Following these anomalies with depth, the 
dual  nature  becomes  more  apparent.  At  greater  depth  only  IP‐07  remains  (see  Figure  3‐22)  as  two 
chargeability anomalies to the north and south of the actual occurrence of Getty North at the surface. 
The two parts of anomaly IP‐07 follow a more or less NNW‐SSW trend, similar to the interpreted faults 
lining up the string of conductors in the DC and MT. 
Both Getty  West and Getty South appear as mainly near surface features,  but  can  be  correlated from 
line to line very nicely. Anomaly IP‐11 can be identified on line 4250N up to a great depth, but the lack of 
coverage to the north and south makes it difficult to verify this anomaly. 
At  an  elevation  of  1000  m,  the  DC  and  IP  models  (Figure  3‐23  and  Figure  3‐24)  show  very  smooth 
representation of the geology, mainly due to the depth of penetration and the smoothness constraint 
use to stabilize the inversion modelling. The MT model is much more sensitive to these greater depth 
and still shows sharp images of the interpreted faulting, continuing the NNE‐SSW trend of features up to 
the 600 m elevation level.  
 
 
 




                                                      47 
QUANTEC GEOSCIENCE LTD 
 


4       CONCLUSIONS AND RECOMMENDATIONS 
A  Titan‐24  DC/IP  and  MT  survey  was  conducted  over  the  Getty  Project,  British  Columbia,  Canada  on 
behalf  of  EffiSolar  Energy  Corp.  and  Getty  Copper  Inc.  between  November  20th  and  December  13th  of 
2010. In total 12 lines of data were collected (23.2 line‐km DC/IP and 19.2 km MT) with a station spacing 
of 100 m. The survey geometry for the DC/IP component was a pole‐dipole geometry. The line spacing 
was 250 m and the lines were located in a staggered fashion over three known deposits: Getty North, 
Getty West and Getty South. 

4.1        RESULTS 
The Titan‐24 Survey was successful in identifying the known Getty North, Getty West and Getty South 
deposits  as  chargeability  anomalies.  Several  NNE‐SSW  striking  faults  were  identified  as  narrow 
conductive features in both the DC and MT models as well as breaks in the chargeability models. 
A borehole dataset was made available 6 and plotted as a reference on selected sections. There is a very 
good correlation between the boreholes targeting the Getty North and South deposits and the location 
of anomalies IP‐07, IP‐08 and IP‐01 respectively (see Figure 4‐1) 
 




                                                                                                                     
                  Figure 4‐1: 2D IP Inversion results (DC model reference) of line 4000N with borehole 
                             locations overlay (gold assays in grey, copper assays in green). 
 
It appears that the high gold assays observed in the Getty North boreholes (Figure 4‐1) correlate very 
closely to the centers of  the  chargeability anomalies, whereas the high copper assays correlate better 
with the contact between the high‐moderate chargeability features. 




                                                            
6
     Personal communications with Mr. C. Anderson, Getty Copper Inc.  


                                                                         48 
QUANTEC GEOSCIENCE LTD 
 




                                                                                                            
           Figure 4‐2: 2D IP Inversion results (DC model reference) of line 750N with borehole 
                                 locations overlay (copper assays in red). 
For  the  Getty  South  deposit,  the  high  copper  assays  correlate  very  well  with  the  center  of  the 
chargeability anomaly, with more potential to depth. 
 
 




                                                     49 
QUANTEC GEOSCIENCE LTD 
 


 




                                                                                    
    Figure 4‐3: 2D IP results: 1600 m plan map with borehole locations overlay. 
 


                                        50 
QUANTEC GEOSCIENCE LTD 
 


 
Summarizing the results of this survey the following conclusions can be drawn: 
    •    Resistivity  distribution  (DC  &  MT)  show  a  succession  of  curved,  sub‐horizontal  conductive  
         features and South‐Southwest‐North‐Northeast faulting trend; 
    •    Chargeability signature is fairly weak except for the known deposits and appears to be related to 
         the interpreted faulting; 
    •    Getty North is likely composed of two centers, where the western center extends further north‐
         east in a similar azimuth as the interpreted faults. Resistivity is moderate‐low; 
    •    Getty  West  is  a  near  surface  (<300  m  depth)  feature  of  weak‐moderate  chargeability  & 
         moderate‐low resistivity; 
    •    Getty South is  a low resistivity, weak‐moderate chargeability feature extending to approx. 350 
         m below the surface; 
    •    In  total  thirty‐nine  (39)  geophysical  anomalies  were  identified,  of  which  twelve  (12)  are 
         classified  as  high  priority.  Sixteen  (16)  anomalies  fall  in  the  medium  priority  classification  and 
         eleven  (11)  are  labeled  as  low  priority.  Prioritization  was  based  on  correlation  between 
         conductive  and  chargeable  features  and  depth  below  the  surface.  A  complete  overview  of  all 
         anomalies can be found in the table below. 
 
Anomaly  line          location  depth         DC               IP         MT         priority  remarks 
ID                                             signature        signature  signature 
IP‐01        250       2110‐        110‐       mod              Mod‐low  ‐                2           Partial 
                       2500         480                                                               correlation 
                                                                                                      with DC‐01 
DC‐01        250       2110‐        130‐       Mod‐low          Mod‐low  ‐                2            
                       26110        480 
DC‐02        250       2720‐        0‐230      mod              low         ‐             3            
                       3030 
IP‐01        500       2100‐        70‐440  Mod‐high            Mod‐        ‐             2           Possible fault 
                       2530                                     high 
DC‐03        500       2590‐        210‐       Mod=‐low  low                ‐             3            
                       3000         500 
IP‐01        750       2100‐        60‐500  mod                 Low‐mod  ‐                2            
                       2380 
DC‐04        750       2240‐        50‐180  Mod‐low             low         ‐             2           Correlation 
                       2420                                                                           with top of IP‐
                                                                                                      01 
IP‐03        750       2410‐        40‐250  mod                 low         ‐             3               Getty south 
                       2620 




                                                          51 
QUANTEC GEOSCIENCE LTD 
 


Anomaly  line     location  depth    DC              IP         MT         priority  remarks 
ID                                   signature       signature  signature 
DC‐05     750     2840‐     100‐     Mod‐low         low        ‐          3         
                  3210      340 
IP‐01     1000    2010‐     90‐350  Mod‐low          Mod‐       ‐          1        Getty 
                  2190                               high                           South/Possible 
                                                                                    fault 
DC‐04?    1000    2150‐     140‐     Mod‐low         low        ‐          3         
                  24230     410 
IP‐03     1000    2280‐     60‐200  low              Mod‐low  ‐            2        Getty south 
                  2510 
DC‐05     1000    2730‐     30‐300  low              low        ‐          3         
                  3080 
IP‐04     3000    39850‐    150‐     mod             mod        mod        2         
                  40040     410 
DC‐06     3000    40020‐    50‐      low             low        mod        3        Possible sub‐
                  40690     2340                                                    horizontal 
                                                                                    feature 
IP‐05     3000    40320‐    200‐     mod             Mod0       mod        2         
                  40600     430 
MT‐01     3000    40900‐    290‐     Mod‐low         Mod‐low  low          1         
                  41820     820 
IP‐08     3000    41250‐    290‐     mod             Mod‐;pw  low          2        Correlates well 
                  41720     540                                                     with MT‐01 
IP‐04     3250    39390‐    380‐     low             mod        low        1         
                            630 
                  39600 
DC‐06     3250    39830‐    140‐     low             Mod‐low  Mod‐low  2             
                  40060     400 
IP‐05     3250    39930‐    290‐     low             mod        mod        1        Correlates with 
                  40120     450                                                     bottom of DC‐
                                                                                    05 
IP‐07     3250    40290‐    110‐     mod             Mod‐       Mod‐low  1          Getty West 
                  40500     270                      high 
IP‐08     3250    40590‐    480‐     low             low        Mod‐low  3           
                  40710     630 
IP‐07     3500    40140‐    150‐     Mod‐high        mod        high       3        Getty West 
                  40440     350 
DC‐07     3500    40520‐    90‐320  low              low        mod        3         



                                               52 
QUANTEC GEOSCIENCE LTD 
 


Anomaly  line     location  depth    DC              IP         MT         priority  remarks 
ID                                   signature       signature  signature 
                  40980 
IP‐06     3500    41220‐   260‐      mod             Mod‐       mod           2     Getty North 
                  41630    620                       high 
IP‐09     3500    41690‐   180‐      Mod‐low         Mod‐       Mod‐low  2          Getty North 
                  41950    370                       high 
IP‐10     3750    39850‐   260‐      Low‐mod         Low‐mod  Low‐mod  2            Possibly 
                  40100    480                                                      associated 
                                                                                    with fault 
IP‐07     3750    40220‐   80‐230  Low‐mod           Low‐mod  Low‐mod  1            Getty West 
                  40400 
IP‐11     3750    40500‐   280‐      Low‐mod         Low‐mod  low             2     Possibly 
                  40690    600                                                      associated 
                                                                                    with fault 
IP‐06     3750    41170‐   290‐      mod             high       low           1     Getty North 
                  41420    500 
IP‐09     3750    41480‐   80‐420  mod               high       mod           1     Getty North 
                  41870 
IP‐06     4000    41310‐   90‐380  mod               high       mod           1     Getty North 
                  41640 
IP‐09     4000    41620‐   0‐210     Mod‐low         high       mod           1     Getty North 
                  41920 
DC‐08     4000    42620‐   0‐430     low             low        low           3     Possible fault 
                  4300 
IP‐12     4250    39960‐   370‐      Mod‐low         mod        mod           2      
                  40460    840 
IP‐06     4250    41540‐   100‐      Mod‐low         Mod‐       mod           1      
                  41940    530                       high 
DC‐09     4250    41660‐   200‐      low             Mod‐       Mod‐low  1          Correlates with 
                  42000    460                       high                           bottom of IP‐
                                                                                    06 
IP‐06     4500    4147‐    290‐      mod             Mod‐       mod           2     Chargeable 
                  41980    720                       high                           center of 
                                                                                    formational 
                                                                                    anomaly? 

                       Table 3: Geophysical Targets for the Getty Project. 
                             



                                               53 
QUANTEC GEOSCIENCE LTD 
 


 
 

ARRE VERWEERD 
I, Arre Verweerd, declare that: 
        I am a consultant with residence in Toronto, Ontario and am presently employed in this capacity 
        with Quantec Geoscience Ltd., Toronto, Ontario; 
        I obtained a Doctorandus Degree (MSc. equivalent) in Geophysics, from the Universiteit Utrecht, 
        Utrecht,  the  Netherlands  in  2001.    I  also  obtained  a  Doctorate  Degree  in  the  Natural  Sciences 
        (Dr. Rer. Nat.), subject Applied Geophysics from the Rheinische‐Friedrich‐Wilhelms‐Universität‐
        zu‐Bonn, Bonn, Germany in 2007; 
        I  have  practiced  my  profession  continuously  since  January  2002,  in  Europe,  South  America, 
        North America, Africa, and Asia. 
        I  am  a  member  of  the  European  Association  of  Geoscientists  and  Engineers  (EAGE),  the 
        European  Geosciences  Union  (EGU),  the  Environmental  and  Engineering  Geophysical  Society 
        (EEGS), the society of Exploration Geophysicists (SEG) and the Canadian Exploration Geophysical 
        Society (KEGS).  
        I  have  no  interest,  nor  do  I  expect  to  receive  any  interest  in  the  properties  or  securities  of 
        EffiSolar Energy Corp./Getty Copper Inc., its subsidiaries or its joint‐venture partners; 
        I  was  in  charge  of  data  acquisition  quality  control,  I  have  reviewed  the  survey  results  and  can 
        attest that these accurately and faithfully reflect the data acquired on site; I undertook the 2D 
        DC/IP  inversions,  I  am  the  author  of  this  interpretation  report  and  have  reviewed  the 
        appendices.  The  statements  made  in  this  report  represent  my  professional  opinion  in 
        consideration of the information available to me at the time of writing this report. 
Toronto, Ontario 
February, 2011 
 
 
 
 
 
Arre Job Verweerd Dr. Rer. Nat. 
Quantec Geoscience Ltd 
                                    




                                                         56 
QUANTEC GEOSCIENCE LTD 
 


 
 

JASON METCALFE 
I, Jason Metcalfe, declare that: 
        I am a Data Processor with residence in Mississauga, Ontario and am presently employed in this 
        capacity with Quantec Geoscience Ltd., Toronto, Ontario; 
        I  obtained  a  Bachelor  of  Science  (B.Sc.)  Geophysics  in  2007  from  the  University  of  Western 
        Ontario, London, Ontario. 
        I  have  practiced  my  profession  continuously  since  October,  2009  in  Canada  and  the  United 
        States; 
        I  have  no  interest,  nor  do  I  expect  to  receive  any  interest  in  the  properties  or  securities  of 
        EffiSolar Energy Corp./Getty Copper Inc., its subsidiaries or its joint‐venture partners; 
        I was the data processor on site, responsible for the quality control of data acquired throughout 
        the  survey.  I  compiled  and  edited  the  logistics  report.  The  statements  made  in  this  report 
        represent  my  professional  opinion  based  on  my  consideration  of  the  information  available  to 
        me at the time of writing this report. 
Toronto, Ontario 
February, 2010 
 
 
 
 
Jason Metcalfe, B.Sc. 
Quantec Geoscience Ltd. 
 




                                                         57 
QUANTEC GEOSCIENCE LTD 
 


6   DIGITAL ARCHIVE 
The CD or DVD attached to this report contains a copy of all the inversion results, final processed data, 
including the survey files, the daily processing (and field) notes, and an electronic copy of this report. 
 
 
 
 
 




                                                   58 
QUANTEC GEOSCIENCE LTD 
 


A SURVEY LOGISTICS 
A.1     ACCESS 
            Base of Operation:                        Copper Valley Motor Inn 
                                                      Logan Lake 
                                                      British Columbia 
            Mode of Access to Grid:                   Trucks 
            Mode of Access to Lines:                  Trucks, ATV and Snow mobiles. 

A.2     SURVEY GRID AREA 
            Established by:                           Getty Copper 
            Coordinate Reference System:              Grid referenced to UTM Coordinates 
            Datum & Projection:                       WGS 84 Zone 10U 
            Grid Azimuth:                             90o 
            Magnetic Declination:                     19oE 
            Station Interval:                         100m 
            Method of Chaining:                       GPS and picketing. 
 
                                  Surveyed Line‐start and ‐end point coordinates. 
                Grid Coordinate              UTM Coordinate Start                  UTM Coordinate End 
    Line 
                Start          End         Easting            Northing           Easting       Northing 
    L250N       2000E        3000E        641999              5600250            642974         5600250 
    L500N       2000E        3000E        642000              5600500            642971         5600516 
    L750N       2000E        3000E        641997              5600744            642979         5600749 
L1000N          2000E        3000E        641993              5600996            642965         5601010 
L3000N         39600E        42000E       639601              5602996            641963         5603007 
L3250N         39100E        41500E       639121              5603249            641686         5603254 
L3500N         40000E        42400E       639998              5603493            642347         5603518 
L3750N         39600E        42000E       639676              5603748            642000         5603751 
L4000N         40600E        43000E       640629              5603998            642949         5604003 
L4250N         39600E        42000E       639598              5604258            641904         5604246 
L4500N         41000E        43400E       641020              5604506            643369         5604505 
L5000N         41100E        43500E       641096              5604999            643432         5605007 
 



                                                        59 
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project
TITAN-24 DC/IP/MT Survey Report for Getty Project

Weitere ähnliche Inhalte

Ähnlich wie TITAN-24 DC/IP/MT Survey Report for Getty Project

61557874 volume-i-ericsson-umts-rf-optimization-12 dec2003
61557874 volume-i-ericsson-umts-rf-optimization-12 dec200361557874 volume-i-ericsson-umts-rf-optimization-12 dec2003
61557874 volume-i-ericsson-umts-rf-optimization-12 dec2003Mohammad Khamiseh
 
Guia de instalacao at 8000 s
Guia de instalacao at 8000 sGuia de instalacao at 8000 s
Guia de instalacao at 8000 sNetPlus
 
Eastern Alberta Transmission Line
Eastern Alberta Transmission LineEastern Alberta Transmission Line
Eastern Alberta Transmission LineDaniela O'Callaghan
 
Original Mosfet N-channel IPAW60R600 60S600CE 600V 6A TO-220F New
Original Mosfet N-channel IPAW60R600 60S600CE 600V 6A TO-220F NewOriginal Mosfet N-channel IPAW60R600 60S600CE 600V 6A TO-220F New
Original Mosfet N-channel IPAW60R600 60S600CE 600V 6A TO-220F NewAUTHELECTRONIC
 
CIGS Photovoltaics Markets-2012
CIGS Photovoltaics Markets-2012CIGS Photovoltaics Markets-2012
CIGS Photovoltaics Markets-2012n-tech Research
 
Case 580 lsp loader backhoe service repair manual
Case 580 lsp loader backhoe service repair manualCase 580 lsp loader backhoe service repair manual
Case 580 lsp loader backhoe service repair manualfjskefkemms
 
Case 580 sle loader backhoe service repair manual
Case 580 sle loader backhoe service repair manualCase 580 sle loader backhoe service repair manual
Case 580 sle loader backhoe service repair manualfjjskekmsemm
 
Case 580 lps loader backhoe service repair manual
Case 580 lps loader backhoe service repair manualCase 580 lps loader backhoe service repair manual
Case 580 lps loader backhoe service repair manualfjkskekkemmmd
 
Case 580 le loader backhoe service repair manual
Case 580 le loader backhoe service repair manualCase 580 le loader backhoe service repair manual
Case 580 le loader backhoe service repair manualfjkskekkemmmd
 

Ähnlich wie TITAN-24 DC/IP/MT Survey Report for Getty Project (10)

61557874 volume-i-ericsson-umts-rf-optimization-12 dec2003
61557874 volume-i-ericsson-umts-rf-optimization-12 dec200361557874 volume-i-ericsson-umts-rf-optimization-12 dec2003
61557874 volume-i-ericsson-umts-rf-optimization-12 dec2003
 
Guia de instalacao at 8000 s
Guia de instalacao at 8000 sGuia de instalacao at 8000 s
Guia de instalacao at 8000 s
 
electronics - power mosfets.pdf
electronics - power mosfets.pdfelectronics - power mosfets.pdf
electronics - power mosfets.pdf
 
Eastern Alberta Transmission Line
Eastern Alberta Transmission LineEastern Alberta Transmission Line
Eastern Alberta Transmission Line
 
Original Mosfet N-channel IPAW60R600 60S600CE 600V 6A TO-220F New
Original Mosfet N-channel IPAW60R600 60S600CE 600V 6A TO-220F NewOriginal Mosfet N-channel IPAW60R600 60S600CE 600V 6A TO-220F New
Original Mosfet N-channel IPAW60R600 60S600CE 600V 6A TO-220F New
 
CIGS Photovoltaics Markets-2012
CIGS Photovoltaics Markets-2012CIGS Photovoltaics Markets-2012
CIGS Photovoltaics Markets-2012
 
Case 580 lsp loader backhoe service repair manual
Case 580 lsp loader backhoe service repair manualCase 580 lsp loader backhoe service repair manual
Case 580 lsp loader backhoe service repair manual
 
Case 580 sle loader backhoe service repair manual
Case 580 sle loader backhoe service repair manualCase 580 sle loader backhoe service repair manual
Case 580 sle loader backhoe service repair manual
 
Case 580 lps loader backhoe service repair manual
Case 580 lps loader backhoe service repair manualCase 580 lps loader backhoe service repair manual
Case 580 lps loader backhoe service repair manual
 
Case 580 le loader backhoe service repair manual
Case 580 le loader backhoe service repair manualCase 580 le loader backhoe service repair manual
Case 580 le loader backhoe service repair manual
 

Kürzlich hochgeladen

SME IPO and sme ipo listing consultants .pptx
SME IPO and sme ipo listing consultants .pptxSME IPO and sme ipo listing consultants .pptx
SME IPO and sme ipo listing consultants .pptxindia IPO
 
Top Rated Call Girls In Podanur 📱 {7001035870} VIP Escorts Podanur
Top Rated Call Girls In Podanur 📱 {7001035870} VIP Escorts PodanurTop Rated Call Girls In Podanur 📱 {7001035870} VIP Escorts Podanur
Top Rated Call Girls In Podanur 📱 {7001035870} VIP Escorts Podanurdharasingh5698
 
CALL ON ➥8923113531 🔝Call Girls Fazullaganj Lucknow best sexual service
CALL ON ➥8923113531 🔝Call Girls Fazullaganj Lucknow best sexual serviceCALL ON ➥8923113531 🔝Call Girls Fazullaganj Lucknow best sexual service
CALL ON ➥8923113531 🔝Call Girls Fazullaganj Lucknow best sexual serviceanilsa9823
 
Corporate Presentation Probe May 2024.pdf
Corporate Presentation Probe May 2024.pdfCorporate Presentation Probe May 2024.pdf
Corporate Presentation Probe May 2024.pdfProbe Gold
 
VVIP Pune Call Girls Sopan Baug WhatSapp Number 8005736733 With Elite Staff A...
VVIP Pune Call Girls Sopan Baug WhatSapp Number 8005736733 With Elite Staff A...VVIP Pune Call Girls Sopan Baug WhatSapp Number 8005736733 With Elite Staff A...
VVIP Pune Call Girls Sopan Baug WhatSapp Number 8005736733 With Elite Staff A...SUHANI PANDEY
 
Call Girls In Amritsar 💯Call Us 🔝 76967 34778🔝 💃 Independent Escort In Amritsar
Call Girls In Amritsar 💯Call Us 🔝 76967 34778🔝 💃 Independent Escort In AmritsarCall Girls In Amritsar 💯Call Us 🔝 76967 34778🔝 💃 Independent Escort In Amritsar
Call Girls In Amritsar 💯Call Us 🔝 76967 34778🔝 💃 Independent Escort In Amritsaronly4webmaster01
 
Q3 FY24 Earnings Conference Call Presentation
Q3 FY24 Earnings Conference Call PresentationQ3 FY24 Earnings Conference Call Presentation
Q3 FY24 Earnings Conference Call PresentationSysco_Investors
 
VIP 7001035870 Find & Meet Hyderabad Call Girls Miyapur high-profile Call Girl
VIP 7001035870 Find & Meet Hyderabad Call Girls Miyapur high-profile Call GirlVIP 7001035870 Find & Meet Hyderabad Call Girls Miyapur high-profile Call Girl
VIP 7001035870 Find & Meet Hyderabad Call Girls Miyapur high-profile Call Girladitipandeya
 
Collective Mining | Corporate Presentation - May 2024
Collective Mining | Corporate Presentation - May 2024Collective Mining | Corporate Presentation - May 2024
Collective Mining | Corporate Presentation - May 2024CollectiveMining1
 
B2 Interpret the brief.docxccccccccccccccc
B2 Interpret the brief.docxcccccccccccccccB2 Interpret the brief.docxccccccccccccccc
B2 Interpret the brief.docxcccccccccccccccMollyBrown86
 
VIP 7001035870 Find & Meet Hyderabad Call Girls Shamshabad high-profile Call ...
VIP 7001035870 Find & Meet Hyderabad Call Girls Shamshabad high-profile Call ...VIP 7001035870 Find & Meet Hyderabad Call Girls Shamshabad high-profile Call ...
VIP 7001035870 Find & Meet Hyderabad Call Girls Shamshabad high-profile Call ...aditipandeya
 
Enjoy Night⚡Call Girls Udyog Vihar Gurgaon >༒8448380779 Escort Service
Enjoy Night⚡Call Girls Udyog Vihar Gurgaon >༒8448380779 Escort ServiceEnjoy Night⚡Call Girls Udyog Vihar Gurgaon >༒8448380779 Escort Service
Enjoy Night⚡Call Girls Udyog Vihar Gurgaon >༒8448380779 Escort ServiceDelhi Call girls
 
Teck Investor Presentation, April 24, 2024
Teck Investor Presentation, April 24, 2024Teck Investor Presentation, April 24, 2024
Teck Investor Presentation, April 24, 2024TeckResourcesLtd
 
Editing progress 20th march.docxxxxxxxxx
Editing progress 20th march.docxxxxxxxxxEditing progress 20th march.docxxxxxxxxx
Editing progress 20th march.docxxxxxxxxxMollyBrown86
 
CALL ON ➥8923113531 🔝Call Girls Vineet Khand Lucknow best Night Fun service 🧦
CALL ON ➥8923113531 🔝Call Girls Vineet Khand Lucknow best Night Fun service  🧦CALL ON ➥8923113531 🔝Call Girls Vineet Khand Lucknow best Night Fun service  🧦
CALL ON ➥8923113531 🔝Call Girls Vineet Khand Lucknow best Night Fun service 🧦anilsa9823
 
Best investment platform in india-Falcon Invoice Discounting
Best investment platform in india-Falcon Invoice DiscountingBest investment platform in india-Falcon Invoice Discounting
Best investment platform in india-Falcon Invoice DiscountingFalcon Invoice Discounting
 

Kürzlich hochgeladen (20)

SME IPO and sme ipo listing consultants .pptx
SME IPO and sme ipo listing consultants .pptxSME IPO and sme ipo listing consultants .pptx
SME IPO and sme ipo listing consultants .pptx
 
Top Rated Call Girls In Podanur 📱 {7001035870} VIP Escorts Podanur
Top Rated Call Girls In Podanur 📱 {7001035870} VIP Escorts PodanurTop Rated Call Girls In Podanur 📱 {7001035870} VIP Escorts Podanur
Top Rated Call Girls In Podanur 📱 {7001035870} VIP Escorts Podanur
 
Call Girls 🫤 Hauz Khas ➡️ 9999965857 ➡️ Delhi 🫦 Russian Escorts FULL ENJOY
Call Girls 🫤 Hauz Khas ➡️ 9999965857  ➡️ Delhi 🫦  Russian Escorts FULL ENJOYCall Girls 🫤 Hauz Khas ➡️ 9999965857  ➡️ Delhi 🫦  Russian Escorts FULL ENJOY
Call Girls 🫤 Hauz Khas ➡️ 9999965857 ➡️ Delhi 🫦 Russian Escorts FULL ENJOY
 
CALL ON ➥8923113531 🔝Call Girls Fazullaganj Lucknow best sexual service
CALL ON ➥8923113531 🔝Call Girls Fazullaganj Lucknow best sexual serviceCALL ON ➥8923113531 🔝Call Girls Fazullaganj Lucknow best sexual service
CALL ON ➥8923113531 🔝Call Girls Fazullaganj Lucknow best sexual service
 
Corporate Presentation Probe May 2024.pdf
Corporate Presentation Probe May 2024.pdfCorporate Presentation Probe May 2024.pdf
Corporate Presentation Probe May 2024.pdf
 
VVIP Pune Call Girls Sopan Baug WhatSapp Number 8005736733 With Elite Staff A...
VVIP Pune Call Girls Sopan Baug WhatSapp Number 8005736733 With Elite Staff A...VVIP Pune Call Girls Sopan Baug WhatSapp Number 8005736733 With Elite Staff A...
VVIP Pune Call Girls Sopan Baug WhatSapp Number 8005736733 With Elite Staff A...
 
Call Girls In Amritsar 💯Call Us 🔝 76967 34778🔝 💃 Independent Escort In Amritsar
Call Girls In Amritsar 💯Call Us 🔝 76967 34778🔝 💃 Independent Escort In AmritsarCall Girls In Amritsar 💯Call Us 🔝 76967 34778🔝 💃 Independent Escort In Amritsar
Call Girls In Amritsar 💯Call Us 🔝 76967 34778🔝 💃 Independent Escort In Amritsar
 
Russian Call Girls Rohini Sector 3 💓 Delhi 9999965857 @Sabina Modi VVIP MODEL...
Russian Call Girls Rohini Sector 3 💓 Delhi 9999965857 @Sabina Modi VVIP MODEL...Russian Call Girls Rohini Sector 3 💓 Delhi 9999965857 @Sabina Modi VVIP MODEL...
Russian Call Girls Rohini Sector 3 💓 Delhi 9999965857 @Sabina Modi VVIP MODEL...
 
Q3 FY24 Earnings Conference Call Presentation
Q3 FY24 Earnings Conference Call PresentationQ3 FY24 Earnings Conference Call Presentation
Q3 FY24 Earnings Conference Call Presentation
 
VIP 7001035870 Find & Meet Hyderabad Call Girls Miyapur high-profile Call Girl
VIP 7001035870 Find & Meet Hyderabad Call Girls Miyapur high-profile Call GirlVIP 7001035870 Find & Meet Hyderabad Call Girls Miyapur high-profile Call Girl
VIP 7001035870 Find & Meet Hyderabad Call Girls Miyapur high-profile Call Girl
 
Collective Mining | Corporate Presentation - May 2024
Collective Mining | Corporate Presentation - May 2024Collective Mining | Corporate Presentation - May 2024
Collective Mining | Corporate Presentation - May 2024
 
B2 Interpret the brief.docxccccccccccccccc
B2 Interpret the brief.docxcccccccccccccccB2 Interpret the brief.docxccccccccccccccc
B2 Interpret the brief.docxccccccccccccccc
 
Rohini Sector 17 Call Girls Delhi 9999965857 @Sabina Saikh No Advance
Rohini Sector 17 Call Girls Delhi 9999965857 @Sabina Saikh No AdvanceRohini Sector 17 Call Girls Delhi 9999965857 @Sabina Saikh No Advance
Rohini Sector 17 Call Girls Delhi 9999965857 @Sabina Saikh No Advance
 
VIP 7001035870 Find & Meet Hyderabad Call Girls Shamshabad high-profile Call ...
VIP 7001035870 Find & Meet Hyderabad Call Girls Shamshabad high-profile Call ...VIP 7001035870 Find & Meet Hyderabad Call Girls Shamshabad high-profile Call ...
VIP 7001035870 Find & Meet Hyderabad Call Girls Shamshabad high-profile Call ...
 
Call Girls 🫤 East Of Kailash ➡️ 9999965857 ➡️ Delhi 🫦 Russian Escorts FULL ...
Call Girls 🫤 East Of Kailash ➡️ 9999965857  ➡️ Delhi 🫦  Russian Escorts FULL ...Call Girls 🫤 East Of Kailash ➡️ 9999965857  ➡️ Delhi 🫦  Russian Escorts FULL ...
Call Girls 🫤 East Of Kailash ➡️ 9999965857 ➡️ Delhi 🫦 Russian Escorts FULL ...
 
Enjoy Night⚡Call Girls Udyog Vihar Gurgaon >༒8448380779 Escort Service
Enjoy Night⚡Call Girls Udyog Vihar Gurgaon >༒8448380779 Escort ServiceEnjoy Night⚡Call Girls Udyog Vihar Gurgaon >༒8448380779 Escort Service
Enjoy Night⚡Call Girls Udyog Vihar Gurgaon >༒8448380779 Escort Service
 
Teck Investor Presentation, April 24, 2024
Teck Investor Presentation, April 24, 2024Teck Investor Presentation, April 24, 2024
Teck Investor Presentation, April 24, 2024
 
Editing progress 20th march.docxxxxxxxxx
Editing progress 20th march.docxxxxxxxxxEditing progress 20th march.docxxxxxxxxx
Editing progress 20th march.docxxxxxxxxx
 
CALL ON ➥8923113531 🔝Call Girls Vineet Khand Lucknow best Night Fun service 🧦
CALL ON ➥8923113531 🔝Call Girls Vineet Khand Lucknow best Night Fun service  🧦CALL ON ➥8923113531 🔝Call Girls Vineet Khand Lucknow best Night Fun service  🧦
CALL ON ➥8923113531 🔝Call Girls Vineet Khand Lucknow best Night Fun service 🧦
 
Best investment platform in india-Falcon Invoice Discounting
Best investment platform in india-Falcon Invoice DiscountingBest investment platform in india-Falcon Invoice Discounting
Best investment platform in india-Falcon Invoice Discounting
 

TITAN-24 DC/IP/MT Survey Report for Getty Project

  • 1.   TITAN‐24 DC / IP / MT SURVEY   GEOPHYSICAL REPORT  GETTY PROJECT  (BRITISH COLUMBIA, CANADA)  ON BEHALF OF  EFFISOLAR ENERGY CORP./GETTY COPPER INC.  (BRITISH COLUMBIA, CANADA)          QUANTEC GEOSCIENCE LTD    BENOÎT TOURNERIE, PGEO  146 SPARKS AVE, TORONTO, ONTARIO, M2H 2S4, CANADA   ARRE VERWEERD  PHONE: (416) 306‐1941 / FAX: (416) 306‐1949    JASON METCALFE  WWW.QUANTECGEOSCIENCE.COM    20/07/2011 
  • 2. QUANTEC GEOSCIENCE LTD    EXECUTIVE SUMMARY    INTRODUCTION  A  Titan‐24  DC/IP  and  MT  survey  was  conducted  over  the  Getty  Project,  British  Columbia,  Canada  on  behalf  of  EffiSolar  Energy  Corp.  and  Getty  Copper  Inc.  between  November  20th  and  December  13th  of  2010. In total 12 lines of data were collected (23.2 line‐km DC/IP and 19.2 km MT) with a station spacing  of 100 m. The survey geometry for the DC/IP component was a pole‐dipole geometry. The line spacing  was 250 m and the lines were located in a staggered fashion over three known deposits: Getty North,  Getty West and Getty South.  SURVEY OBJECTIVES  The  objectives  of  this  survey  are  to  further  delineate  the  geophysical  signatures  of  the  Getty  North,  Getty West and Getty South deposits and identify potential other features of interest.  RESULTS  The survey was successful in identifying the Getty North, West and South Deposits. Overall data quality  was high. Summarizing the results of this survey the following conclusions can be drawn:    • Resistivity  distribution  (DC  &  MT)  show  a  succession  of  curved,  sub‐horizontal  conductive   features and South‐Southwest‐North‐Northeast faulting trend  • Chargeability signature is fairly weak except for the known deposits and appears to be related to  the interpreted faulting.   • Getty North is likely composed of two centers, where the western center extends further north‐ east in a similar azimuth as the interpreted faults. Resistivity is moderate‐low.  • Getty  West  is  a  near  surface  (<300  m  depth)  feature  of  weak‐moderate  chargeability  &  moderate‐low resistivity.  • Getty South is  a low resistivity, weak‐moderate chargeability feature extending to approx. 350  m below the surface  • In  total  thirty‐nine  (39)  geophysical  anomalies  were  identified,  of  which  twelve  (12)  are  classified  as  high  priority.  Sixteen  (16)  anomalies  fall  in  the  medium  priority  classification  and  eleven (11) are labeled as low priority.  A complete overview of all anomalies can be found in  the conclusions section, the high priority targets have been listed in the table below.          2 
  • 3. QUANTEC GEOSCIENCE LTD      Anomaly  Line  Location  Depth  DC  IP  MT  remarks  ID  signature  signature  signature  IP‐01  1000  2010‐ 90‐350  Mod‐low  Mod‐high    Getty South/  2190  Possible fault  MT‐01  3000  40900‐ 290‐ Mod‐low  Mod‐low  low    41820  820  IP‐04  3250  39390‐  380‐ low  mod  low    630  39600  IP‐05  3250  39930‐ 290‐ low  mod  mod  Correlates with  40120  450  bottom of DC‐05  IP‐07  3250  40290‐ 110‐ mod  Mod‐high  Mod‐low  Getty West  40500  270  IP‐07  3750  40220‐ 80‐230  Low‐mod  Low‐mod  Low‐mod  Getty West  40400  IP‐06  3750  41170‐ 290‐ mod  high  low  Getty North  41420  500  IP‐09  3750  41480‐ 80‐420  mod  high  mod  Getty North  41870  IP‐06  4000  41310‐ 90‐380  mod  high  mod  Getty North  41640  IP‐09  4000  41620‐ 0‐210  Mod‐low  high  mod  Getty North  41920  IP‐06  4250  41540‐ 100‐ Mod‐low  Mod‐high  mod    41940  530  DC‐09  4250  41660‐ 200‐ low  Mod‐high  Mod‐low  Correlates with  42000  460  bottom of IP‐06        3 
  • 4. QUANTEC GEOSCIENCE LTD    TABLE OF CONTENTS  List of Figures ........................................................................................................................................ 6  List of Tables  ......................................................................................................................................... 8  . 1  Introduction ............................................................................................................................. 9  1.1  Survey Objectives ............................................................................................................. 9  1.2  General Survey Information ............................................................................................. 9  2  Previous work & Geology ....................................................................................................... 13  2.1  Getty North .................................................................................................................... 13  2.2  Getty South .................................................................................................................... 15  3  Results and Interpretation ..................................................................................................... 17  3.1  Overview of Inversion Procedure ................................................................................... 17  3.1.1  DC Resistivity & Induced Polarization Inversions ................................................... 17  3.1.2  Audio‐Magnetotelluric Inversions .......................................................................... 18  3.2  Discussion of Results ...................................................................................................... 20  3.2.1  Getty South – Line 250N  ........................................................................................ 21  . 3.2.2  Getty South – Line 500N  ........................................................................................ 22  . 3.2.3  Getty South – Line 750N  ........................................................................................ 23  . 3.2.4  Getty South – Line 1000N  ...................................................................................... 24  . 3.2.5  Getty North – Line 3000N  ...................................................................................... 26  . 3.2.6  Getty North – Line 3250N  ...................................................................................... 28  . 3.2.7  Getty North – Line 3500N  ...................................................................................... 30  . 3.2.8  Getty North – Line 3750N  ...................................................................................... 32  . 3.2.9  Getty North – Line 4000N  ...................................................................................... 34  . 3.2.10  Getty North – Line 4250N  ...................................................................................... 36  . 3.2.11  Getty North – Line 4500N  ...................................................................................... 38  . 3.2.12  Getty North – Line 5000N  ...................................................................................... 39  . 3.2.13  Plan map interpretation ......................................................................................... 40  4  Conclusions and Recommendations ...................................................................................... 48  4.1  Results ............................................................................................................................ 48  5  Statement of Qualifications ................................................................................................... 55  6  Digital Archive ........................................................................................................................ 58  A  Survey Logistics ...................................................................................................................... 59    4 
  • 5. QUANTEC GEOSCIENCE LTD    B  Production Summary ............................................................................................................. 71  C  DC – IP Pseudo‐Sections of Final Processed Data .................................................................. 75  D  MT Soundings Curves of Final Processed Data .................................................................... 123  E  MT Pseudo‐Sections of Final Processed Data ...................................................................... 171  F  Parallel Sensor Test .............................................................................................................. 179  G  Instruments Specifications ................................................................................................... 193  H  Geosoft Sections of the 2D Models ..................................................................................... 199  I  Geosoft Plan Maps of the 2D Models .................................................................................. 225  J  An Introduction to Titan‐24 Direct Current (DC) Resistivity and Induced Polarisation (IP)  Methods ............................................................................................................................... 247  K  Introduction to the Magnetotelluric Method ...................................................................... 257  L  References............................................................................................................................ 263  M  Scaled Geosoft Sections and Maps of the 2D Models ......................................................... 265            5 
  • 6. QUANTEC GEOSCIENCE LTD    LIST OF FIGURES  Figure 1‐1: General project location. .................................................................................................. 11  Figure 1‐2: Claim Map with Titan24 survey Lines. .............................................................................. 11  Figure 1‐3: Getty North and South line location map with topography. ............................................ 12  Figure 2‐1: Local geology of the Getty North deposit. ........................................................................ 14  Figure 2‐2: Local geology of the Getty South Deposit. ....................................................................... 16  Figure 3‐1: Example of DC‐IP misfit curves showing relaxation of the model .................................... 18  Figure 3‐2: Line 250N – 2D inversion results. ..................................................................................... 21  Figure 3‐3: Line 500N – 2D inversion results. ..................................................................................... 22  Figure 3‐4: Line 750N – 2D inversion results. ..................................................................................... 23  Figure 3‐5: Line 1000N – 2D Inversion results. ................................................................................... 24  Figure 3‐6: Line 1000N – 2D Half Space referenced IP model. ........................................................... 25  Figure 3‐7: Line 3000N – 2D inversion results. ................................................................................... 26  Figure 3‐8: Line 3000N – 2D Half Space referenced IP model. ........................................................... 27  Figure 3‐9: Line 3250N – 2D inversion results. ................................................................................... 28  Figure 3‐10: Line 3500N – 2D inversion results. ................................................................................. 30  Figure 3‐11: Line 3750N – 2D inversion results. ................................................................................. 32  Figure 3‐12: Line 3750 N – 2D Half Space referenced IP model. ........................................................ 33  Figure 3‐13: Line 4000N – 2D inversion results. ................................................................................. 34  Figure 3‐14: Line 4250N – 2D inversion results. ................................................................................. 36  Figure 3‐15: Line 4500N – 2D inversion results. ................................................................................. 38  Figure 3‐16: Line 5000 N – 2D inversion results. ................................................................................ 39  Figure 3‐17: DC model plan map, 1600 m Elevation. .......................................................................... 41  Figure 3‐18: IP Model plan map, 1600 m elevation. ........................................................................... 41  Figure 3‐19: DC Model plan map, 1400 m elevation. ......................................................................... 42  Figure 3‐20: IP Model plan map, 1400 m elevation. ........................................................................... 42  Figure 3‐21: DC Model plan map, 1200 m elevation. ......................................................................... 43  Figure 3‐22: IP Model plan map, 1200 m elevation. ........................................................................... 43  Figure 3‐23: DC model plan map, 1000 m elevation.  ......................................................................... 44  . Figure 3‐24: IP Model plan map, 1000 m elevation. ........................................................................... 44  Figure 3‐25: MT model plan map, 1600 m elevation. ......................................................................... 45  Figure 3‐26: MT Model plan map, 1400 m elevation. ......................................................................... 45  Figure 3‐27: MT Model plan map, 1000 m elevation. ......................................................................... 46    6 
  • 7. QUANTEC GEOSCIENCE LTD    Figure 3‐28: MT Model plan map, 600 m elevation. ........................................................................... 46  Figure 4‐1: 2D IP Inversion results (DC model reference) of line 4000N with borehole locations  overlay (gold assays in grey, copper assays in green). ................................................................ 48  Figure 4‐2: 2D IP Inversion results (DC model reference) of line 750N with borehole locations  overlay (copper assays in red). .................................................................................................... 49  Figure 4‐3: 2D IP results: 1600 m plan map with borehole locations overlay. ................................... 50              7 
  • 8. QUANTEC GEOSCIENCE LTD    LIST OF TABLES  Table 1: List of claims surveyed for Getty North and Getty south. ..................................................... 10  Table 2: List of Lots surveyed for Getty South. ................................................................................... 10  Table 3: Geophysical Targets for the Getty Project. ........................................................................... 53              8 
  • 9. QUANTEC GEOSCIENCE LTD    1 INTRODUCTION  This  report  presents  the  logistics  and  the  results  of  the  analysis  of  the  Titan‐24  DC  ‐  IP  ‐  MT  data  acquired  from  2010/11/20  to  2010/12/13  over  the  Getty  Project,  on  behalf  of  EffiSolar  Energy  Corp./Getty Copper Inc..  The  first  part  of  this  report  presents  the  inversion  results,  and  their  geophysical  interpretation,  and  some recommendation for future follow up on the property.  The second part of the report presents the logistics of the survey, including the survey parameters and  methodology, and the survey results (data) in digital documents.  1.1 SURVEY OBJECTIVES  The exploration objective of the Titan 24 DCIP & MT survey at the Getty Project is to detect porphyry  mineralization  at  depth  for  drill  targeting  and  structural  delineation.  Titan  24  should  provide  the  following benefits:  Verify  the  geophysical  anomalies  identified  by  previous  IP  surveys  to  depth  of  300m  around  two  ore  deposits.  And detect further deeper to identify whether there are anomalies under these deposits and showings,  and if so determine intensity, shape and dimensions.  The Titan 24 Distributed Acquisition System (DAS; Sheard, 1998) employs a combination of multiplicity  of  sensors,  24‐bit  digital  sampling,  and  advanced  signal  processing.  It  provides  three  in‐dependent  datasets  capable  of  measuring  subsurface  resistivity’s  (structure,  alteration  &  lithology)  and  chargeability (mineralization) to depth.  The  DC/IP  component  of  the  survey  should  provide  an  excellent  means  of  delineating  target  mineralization  within  the  top  500m  to  750m  pending  geologic  and  cultural  environment.  The  MT  resistivity  provides  additional  resistivity  information  from  surface  to  depths  beyond  1km.  The  MT  resistivity is useful for mapping geological contacts with resistivity contrasts and deep conductors that  may potentially represent alteration or mineralization.  1.2 GENERAL SURVEY INFORMATION  Quantec Project No.:  CA00777T  Client:  EffiSolar Energy Corp./Getty Copper Inc.  Client Address  220‐17 Fawcett Rd     Coquitlam, British Columbia, V3K 6V2     Canada  Client representative:  William Xu     Phone: 604‐555‐0060     Email: william@effisolar.com  Project Name:  Getty Project  Survey Type:  Titan‐24 DC ‐ IP ‐ MT  Project Survey Period:  2010/11/20 to 2010/12/13      9 
  • 10. QUANTEC GEOSCIENCE LTD    General Location:  Approximately 50km South West of Kamloops  Province  British Columbia  Mining division  Kamloops Mining Division  District  Logan Lake  Nearest Settlement:  Logan Lake  Datum & Projection:  WGS 84, Zone 10U  Latitude & Longitude:  Approx. 121°01’44”E, 50°33'43”N  UTM position:  Approx. 639601m E, 5602996m N  List of Claims Surveyed:  Getty North & South: see Table 1 1, and Figure 1‐2.  List of Lots Surveyed:  Getty South see Table 21.    Getty North  543766  758882  759482  759522  766082  218508  218511  221509    221561  221562  221563  221564  221565  221566  221567  221568  221569  221571  221573  221575  221577  221578  221579  221580  221581  221585  Getty South  519232  519237  526953              Table 1: List of claims surveyed for Getty North and Getty South.    5483  5601 5604 5607 5611 5614 5617   5602 5605   5612 5615 5618   5603 5606   5613 5616   Table 2: List of Lots surveyed for Getty South.                                                                     1   List of Claims (Getty North & South) and Lots (Getty South) provided by Percy F. Cox, rep. Getty Copper Inc.    10 
  • 11. QUANTEC GEOSCIENCE LTD      2 Figure 1‐1: General project location .    3 Figure 1‐2: Claim Map  with Titan24 survey Lines.                                                                 2  After Getty Copper Inc. website (www.gettycopper.com/index.php?option=com_content&view=article&id=19&itemid=21).  3   Claim Map from MTO system (https://webmaps.gov.bc.ca/imf5/imf.jsp?site=mem_mto_min‐view‐title).    11 
  • 12. QUANTEC GEOSCIENCE LTD      Figure 1‐3: Getty North and South line location map with topography.      12 
  • 13. QUANTEC GEOSCIENCE LTD    2 PREVIOUS WORK & GEOLOGY 4  The  Getty  Copper  Project  is  located  in  the  Kamloops  Mining  Division  of  British  Columbia,  Canada  and  consists  of  both  the  Getty  North  and  Getty  South  Deposits.  The  area  has  historically  produced  appreciable amounts of copper and molybdenum. To the immediate south of the Getty Copper project  the Highland Valley open pit mine is operated by Teck Resources Ltd.  The  property  has  been  explored  intermittently  since  the  1950’s  with  work  consisting  of  surface  trenching  and  surface  bulk  sampling,  aerial  photographic  surveys  and  base  map  production,  diamond  and  percussion  drilling,  geological  mapping,  assaying,  IP  and  magnetics  geophysical  surveys,  soil  geochemical  surveys  and  metallurgical  testing.  To  date,  diamond  drilling  on  the  Getty  North  property  totals  approximately  46,490  meters  in  210  holes,  and  percussion  drilling  totals  approximately  5724  meters  in  74  holes.  In  addition,  23  kilometers  of  induced  polarization  surveys,  23  kilometers  of  geochemical soil sampling surveys, and detailed geological mapping have been conducted.  2.1 GETTY NORTH   Getty  North  property  totals  approximately  46,490  meters  in  210  holes,  and  percussion  drilling  totals  approximately  5724  meters  in  74  holes.  In  addition,  23  kilometers  of  induced  polarization  surveys,  23  kilometers of geochemical soil sampling surveys, and detailed geological mapping have been conducted.  The  Getty  North  deposit  is  situated  within  the  upper  Triassic  Guichon  Batholith  which  is  part  of  the  Nicola Group of the Quesnel Terrane. The Quesnel Terrane is a west‐facing volcanic island‐arc sequence  that was accreted to the North American plate during the Jurassic age.  The  Guichon  Batholith,  located  60  kilometers  southwest  of  Kamloops,  is  an  elongated  intrusion  25  kilometers wide by 40 kilometers long which hosts several large low‐grade porphyry copper deposits.  The Getty North property is largely underlain by granodiorite cut by a series of porphyry dikes that are  most likely derived from the Bethlehem phase of the batholith. Porphyry style hypogene mineralization  within  the  study  area  consists  mostly  of  chalcopyrite  and  lesser  bornite  in  fractures  and  veins,  as  disseminations,  and  in  breccia  bodies.  Oxidized  mineralization  is  also  present  near  the  Kamloops  unconformity.   Fractures  and  faults  are  prominent,  and  the  areas  of  highest  fracture  density  are  also  the  zones  of  higher‐grade  mineralization.  The  areas  of  higher  fracture  density  are  adjacent  to  the  stock  and  associated with sets of steeply dipping north and northeast trending faults that have dominantly formed  post‐mineralization.  Kamloops  Group  rocks  are  restricted  almost  entirely  to  down‐faulted  blocks  and  associated vertical offsets that have been identified by drilling.                                                                 4   After “National Instrument 43‐101 ‐ Preliminary Feasibility Study Technical Report of the Getty Copper Project” West Coast  Environmental and Engineering, 2009.    13 
  • 14. QUANTEC GEOSCIENCE LTD      Figure 2‐1: Local geology of the Getty North deposit.        14 
  • 15. QUANTEC GEOSCIENCE LTD    2.2 GETTY SOUTH  As with the Getty North Deposit, the Getty South property has been explored intermittently since the  1950’s  with  work  consisting  of  surface  trenching  and  surface  and  underground  bulk  sampling,  underground workings, aerial photographic surveys and base map production, diamond and percussion  drilling,  geological  mapping,  assaying,  IP  and  magnetics  geophysical  surveys,  soil  geochemical  surveys  and  metallurgical  testing.  The  Getty  South  property  has  been  examined  with  almost  4000  meters  of  surface trenching, approximately 20,353 meters of diamond drilling from surface and underground sites,  and  1,719  meters  of  underground  workings.  Most  recently,  an  exploration  program  composed  of  13  reconnaissance  diamond  drill  holes  and  15  surface  trenches  with  a  total  length  of  1,572  meters  were  completed in 1996 and 1997.  The  Getty  South  deposit  is  also  situated  within  the  upper  Triassic  Guichon  Batholith.  The  deposit  is  a  composite  breccia  zone  of  what  was  originally  Guichon  quartz  diorite  that  was  intruded  by  andesite,  rhyolite and porphyritic dikes and related phreato‐magmatic breccias.   The Getty South deposit is located immediately west of a regional north‐south striking structure locally  called the Jersey Fault. A similar parallel‐striking fault, termed the Bethlehem Fault by previous authors,  is located near the east side of the breccia.       15 
  • 16. QUANTEC GEOSCIENCE LTD      Figure 2‐2: Local geology of the Getty South Deposit.        16 
  • 17. QUANTEC GEOSCIENCE LTD    3 RESULTS AND INTERPRETATION  In  this  section,  results  of  the  2D  inversion  of  the  Titan‐24  data  are  presented  as  cross‐sections  along  each survey line. The observed anomalies are described and discussed as potential drilling targets.   The  Titan‐24  system  acquires  three  types  of  geophysical  data  –  magnetotelluric  (MT),  direct  current  resistivity (DC), and induced polarization (IP). The MT and DC method are used to resolve the resistivity  distribution  of  the  subsurface  by  measuring  the  electric  potential  (DC)  and  the  variation  of  natural  source electric and magnetic fields (MT). Resistivity can be an indicator of metallic mineralization, but is  more often than not controlled by rock porosity and is therefore an indirect indicator of alteration and  mineral grain fabric.   In  the  induced  polarization  method,  electrical  capacitance  or  chargeability  of  the  subsurface  is  measured. Chargeability is a near‐direct indicator of the presence of mineralization, in both massive and  disseminated  forms.  This  mineralization  is  most  commonly  various  sulphides  and  graphite,  but  also  includes clay‐type minerals potentially making it a useful tool for base‐metals exploration.   Detail  results,  i.e.  observed  DC‐IP‐MT  data  and  equivalent  calculated  responses  for  each  model,  are  presented  on  a  line  per  line  basis  in  PowerPoint  (PDF)  documents  delivered  in  the  digital  archive  (CD/DVD) attached to this report.  3.1 OVERVIEW OF INVERSION PROCEDURE  3.1.1 DC RESISTIVITY & INDUCED POLARIZATION INVERSIONS  DC‐IP is an electrical method that uses the injection of current and the measurement of voltage along  with  its  rate  of  decay  to  determine  the  subsurface  resistivity  and  chargeability,  respectively.  Depth  of  investigation is mainly controlled by the array geometry, but also the transmitted current, in terms of  signal to noise, particularly for the chargeability. In its standard configuration (a=100m / n=0.5‐23.5) the  Titan‐24 surveys typically image DC resistivity to depths of 500‐750m, and the IP typically images to 500‐ 750m, in sub‐vertical tabular geologic settings and up to 50% more for sub‐horizontal. The differences in  penetration are a function of the relative property contrasts and relative signal‐to‐noise levels between  the  two  measurements.  However  this  investigation  depth  increases  proportionally  to  the  dipole‐size  (i.e., 1000‐1500m for 200m dipoles). A detailed introduction to DC‐IP is given in Telford, et al. (1976).  The primary tool for evaluating the Titan‐24 data is through the inversion of the data in two‐dimensions  (2D). An inversion model depends not only on the data collected, but also on the associated data errors  in the reading and the “model norm”. Inversion models are not unique and may contain “artefacts” from  the inversion process. The inversion model may not accurately reflect all of the information apparent in  the actual data. Inversion models must be reviewed in context with the observed data, model fit, and  with an understanding of the model norm used.  The Titan‐24 DC and IP data were inverted to produce cross‐sections of the resistivity and chargeability  variations along the survey lines. The UBC DCIP2D inversion code (Oldenburg & Li, 1994) was used for  the 2D inversion of the DC and IP data.  Potential  difference  (voltage)  and  phase  values  were  used  as  input  data  in  the  DC  and  IP  inversions,  respectively. DC Resistivity and induced polarization (IP) data are first pre‐conditioned; the error of each  data point is adjusted for the inversion process using a general error equation similar to:    17 
  • 18. QUANTEC GEOSCIENCE LTD    ⎛Vp ⎞ Vp ⎛Vp ⎞ errors⎜ ⎟ = A% ⎜ IP ⎟ + B × Acq_Error⎜ ⎟ + C (floor)  ⎜ IP ⎟ ⎝ ⎠ IP ⎝ ⎠ with the set of parameters  {A, B , C }  adjusted (and large errors data points removed) for each dataset  until we achieve  convergence with relaxation of the DC or IP  models  (see example of  Model Norm fit  curve on Error! Reference source not found.).    Figure 3‐1: Example of DC‐IP misfit curves showing relaxation of the model  Three 2D inversions were carried out along each line.   The DC data was inverted using an unconstrained 2D inversion with a homogenous half‐space of average  input data as starting model. The DC models are labelled as ‘DC’.  Two  IP  inversions  are  calculated  from  the  same  data  set  and  parameters,  but  they  use  a  different  reference  model 5.  The  first  inversion  of  the  IP  data  uses  the  previously  calculated  DC  model  as  the  reference model, and is labelled the ‘IP dcref model’. The second IP inversion uses a homogeneous half‐ space resistivity model as the reference model and is labelled ‘IP hsref model’ or ‘IP nullcon’ model. This  model is included to test the validity of chargeability anomalies, and to limit the possibility of inversion  artefacts in the IP model due to the use of the DC model as a reference.  The DC and IP inversion use the same mesh. The horizontal mesh was set as 3 cells between electrodes  on each line. The vertical mesh was designed with a cell thickness from 10 to 15m for the first 200‐300m  to accommodate the topographic variation along the profile, and then it increases from 20 to 100m with  depth. The inversions were generally run for a maximum of 50 iterations.    3.1.2 AUDIO‐MAGNETOTELLURIC INVERSIONS   The  Audio‐Magnetotelluric  (AMT)  method  is  a  natural  source  method  that  measures  the  variation  of  both  the  electric  (E)  and  magnetic  (H)  field  on  the  surface  of  the  earth  in  order  to  determine  the  distribution  at  depth  of  the  resistivity  of  the  underlying  rocks.  A  complete  review  of  the  method  is  presented in Vozoff (1972) and Orange (1989).                                                               5   The reference model is used to calculate the sensitivity matrix used at each iteration for the IP inversion.    18 
  • 19. QUANTEC GEOSCIENCE LTD    The measured MT impedance Z, defined by the ratio between the E and H fields, is a tensor of complex  numbers. This tensor is generally represented by its two off‐diagonal elements. In a 1D earth model, i.e.  the resistivity varies only with depth, there is no strike direction and the two off‐diagonal impedances  are equal. In the 2D case, i.e. when the resistivity varies with depth and perpendicularly to the strike,  and when the profile is set perpendicular to the strike direction, the two off‐diagonal elements are not  equal  but  reflect  the  variation  of  the  resistivity  along  two  directions,  one  parallel  and  the  other  perpendicular  to  the  strike,  i.e.,  the  TE  (Transverse  Electric;  E  parallel  to  the  strike)  and  the  TM  (Transverse Magnetic; E perpendicular to the strike) modes.   Both TE and TM impedances are represented by an apparent resistivity (a parameter proportional to the  modulus of Z) and a phase (argument of Z). The variation of those parameters with frequency relates the  variations  of  the  resistivity  with  depth,  the  high  frequencies  sampling  the  sub‐surface  and  the  low  frequencies  the  deeper  part  of  the  earth.  However  the  apparent  resistivity  and  the  phase  have  an  opposite behaviour. An increase of the phase indicates a more conductive zone than the host rocks, and  is associated with a decrease of the apparent resistivity. The objective of the inversion of MT data is to  compute a distribution of the resistivity of the surface that explains the variations of the MT parameters,  i.e.  the  response  of  the  model  that  fits  the  observed  data.  The  solution  however  is  not  unique  and  different  inversions  must  be  performed  (different  programs,  different  conditions)  in  order  to  test  and  compare solutions for artefacts versus a target anomaly.  The depth of investigation is determined primarily by the frequency content of the measurement. Depth  estimates  from  any  individual  sounding  may  easily  exceed  20  km.  However,  the  data  can  only  be  confidently interpreted when the aperture of the array is comparable to the depth of investigation. In  the  instance  of  Titan  24  surveys,  inversion  depth  is  generally  limited  to  about  half  the  length  of  the  survey line or profile.  The primary tool for evaluating the Titan MT data is 2D inversion. The inversion model is dependent on  the  data,  but  also  on  the  associated  data  errors,  and  the  model  norm.  The  inversion  models  are  not  unique, may contain artefacts of the inversion process, and may not therefore accurately reflect all of  the  information  apparent  in  the  actual  data.  Inversion  models  need  to  be  reviewed  in  context  of  the  observed  data,  model  fit,  an  understanding  of  the  model  norm  used  and  if  the  model  is  geologically  plausible.  For  this  study,  2D  inversions  were  performed  using  the  unrotated  data,  which  assumes  the  strike  direction is perpendicular to the profile for all sites: the TM mode is then defined by the inline E‐field  (and cross line H‐field), and the TE mode is defined by the cross line E‐field (and inline H‐field) data.  The  MT models were  calculated with the  RLM code (Rodi and  Mackie, 2001)  and with  the PWm  code  (development Quantec Geoscience; based on deLugao and Wannamaker, 1996).   The  inversions  use  the  TE  and  TM  resistivity  and  phase  from  10kHz  to  0.1Hz,  interpolated  at  4  to  6  frequencies per decade, and assume 5% error for the resistivity and 3 degrees error for the phase.  One RLM inversion model (mu_h4) was derived from inverting the TE and TM apparent resistivity and  phase MT data starting from a half space model of 100 Ohm‐m. A second RLM model (mu_d4) also used  the TE and TM phase and rho data but as a starting model a stitched 1D determinant model was used.   The  same  set  of  inversions  models  was  also  calculated  using  the  PWm  code  (pu_h4  starting  from  the  half space model and pu_d4 starting from the 1D determinant).   The  final  2D  inversion  MT  model  presented  in  this  report,  and  used  in  the  interpretation  is  the  RLM  inversion starting from the stitched 1D determinant model, and using TM and TE apparent resistivity and  phase from 10kHz to 0.1Hz, because of its fit to the data and its correlation with the DC and IP models.    19 
  • 20. QUANTEC GEOSCIENCE LTD    3.2 DISCUSSION OF RESULTS  In the following section the resulting DC resistivity, MT resistivity and IP chargeability models, obtained  after inversion of the acquired data will be described. The first part of the discussion will consist of a line  by line description; the second part will deal with plan maps constructed from the 2D inversion results.  On each line anomalies and features of interest will be indicated. The features will be picked based on  the  correlation  between  resistivity  and  chargeability  signatures,  size  and  depth  below  the  surface.  A  table of the results can be found in the conclusion section of this report (Table 3).  For the first set of lines (250N ‐ 1000N) no MT survey was conducted, therefore only the DC model (top  image) and the DC referenced IP model (bottom image) will be shown. From line 3000N onwards the MT  model will  be shown below the IP  model. For selected lines the IP model  calculated with a half space  resistivity model as a reference (HS‐referenced) will also be shown. All models calculated can be found  in the appendices of the report. Many of the northern group of lines have been surveyed with current  extensions,  which  are  indicated  with  the  station  symbol  (inverted  triangle)  on  the  DC  and  IP  section  maps.  The  colour  bars  used  in  all  section  and  plan  maps  will  be  consistent  in  the  report.  In  the  DC  and  MT  resistivity  models  values  of  10  Ohm‐m  correspond  to  the  purple/red  colours  (conductive)  and  10.000  Ohm‐m to white (resistive), in a logarithmic colour scale. For both the dc referenced IP chargeability as  well  as  the  half  space  chargeability  models  a  linear  colour  scale  is  used,  where  the  cool  colour  correspond to 0 mrad, and the warm colours to 25 mrads.              20 
  • 21. QUANTEC GEOSCIENCE LTD    3.2.1 GETTY SOUTH – LINE 250N    Figure 3‐2: Line 250N – 2D inversion results.  Line 250N is the furthest south line covering the Getty South deposit, and is the first line acquired in this  project. The resistivity model shows a conductive overburden with an average thickness of 50 meter. In  the center of the line it appears the thickness of the conductive overburden increases to approximately  100  m.  Two  conductive  features  are  identified  on  this  line,  anomaly  DC‐01  on  the  western  side,  and  anomaly DC‐02 on the eastern side.   Anomaly DC‐01 is an east dipping feature, 150‐200 m thick, and could be connected to the surface. It is  located within a large weak‐moderately chargeable zone, which likely has a formational nature. Within  this  broad  chargeability  feature  a  center  of  moderate  chargeability  values  is  observed  (IP‐01),  correlating with the location of DC‐01 but with an apparent different dip.   The second conductor on the line (DC‐02) is located close to the surface, and extends only to depths of  approximately  200  meter  below  the  surface.  Anomaly  DC‐02  is  located  in  a  region  without  any  chargeability signature.        21 
  • 22. QUANTEC GEOSCIENCE LTD    3.2.2 GETTY SOUTH – LINE 500N    Figure 3‐3: Line 500N – 2D inversion results.  The second line of the survey is located 250 meter  further  north, and parallel to line 250N. Again  the  resistivity model shows a conductive overburden with an average thickness of approximately 50 m, but  locally  extending  to  100  meter  below  the  surface.  The  deeper  part  of  the  resistivity  model  shows  a  moderate  resistivity  without  many  features.  At  depth  between  250  and  300m,  a  more  conductive  feature is observed (DC‐03); it is located in a region of low chargeability. A single chargeability anomaly  is  observed  on  line  500N  (IP‐01).  The  anomaly  IP‐01  is  located  just  below  the  conductive  overburden  and  extends  to  a  depth  of  approximately  400  m  below  the  surface.  It  has  a  moderate‐strong  chargeability  signature,  and  it  is  sharply  bound  on  the  eastern  side.  It  seems  to  correlate  with  the  moderate chargeability anomaly observed on Line 250N (IP‐01).        22 
  • 23. QUANTEC GEOSCIENCE LTD    3.2.3 GETTY SOUTH – LINE 750N    Figure 3‐4: Line 750N – 2D inversion results.  Chargeability anomaly IP‐01 can also be observed on line 750N, although its signature is reduced to a  moderate chargeability feature. Anomaly IP‐01 is sharply bound to the east  and west on  this line, the  western boundary is a narrow conductive, near vertical feature. This feature has the resistivity signature  of a fault, and is identified as such on the section.   A second moderate (smaller) chargeability feature IP‐02 is observed on this line. This anomaly is located  below the conductive overburden and separated from IP‐01 by a small conductive feature (DC‐04). Also  present on this line is anomaly DC‐03, in the eastern part of the line and appears to have moved closer  towards the surface.        23 
  • 24. QUANTEC GEOSCIENCE LTD    3.2.4 GETTY SOUTH – LINE 1000N    Figure 3‐5: Line 1000N – 2D Inversion results.  The upwards trend of anomaly  DC‐03  can also be observed on the final line  covering  the  Getty  South  deposit, where DC‐03 is located just below the overburden, and has a very conductive signature.  Also  anomalies  IP‐01  and  IP‐02  are  observed  on  this  line  again,  although  IP‐01  has  a  much  smaller  signature  when  compared  to  the  previous  lines.  Both  features  are  again  separated  by  a  conductive  anomaly,  which  could  be  related  to  DC‐04.  Anomaly  IP‐01  is  again  bound  on  its  western  side  by  an  interpreted fault, although the geometry of the survey does not allow a very deep interpretation at this  part of the line. The chargeability anomalies identified on this line are very well represented in the Half  Space referenced IP model presented in Figure 3‐6.      24 
  • 25. QUANTEC GEOSCIENCE LTD      Figure 3‐6: Line 1000N – 2D Half Space referenced IP model.          25 
  • 26. QUANTEC GEOSCIENCE LTD    3.2.5 GETTY NORTH – LINE 3000N    Figure 3‐7: Line 3000N – 2D inversion results.        26 
  • 27. QUANTEC GEOSCIENCE LTD    Line  3000N  is  the  first  full  length  2.4  km  Titan‐24  setup,  and  the  first  line  where  DC/IP  and  MT  was  acquired. Both DC and MT resistivity show a sub horizontal layered response for the eastern side of the  line. At least two conductive bands can be identified; the top one is located approximately 150 m below  the surface, and the bottom one between 300 and 350 meters below the surface. These two features  curved  towards  the  surface  in  the  middle  of  the  line,  and  abruptly  terminate.  This  geometry  is  also  observed in the chargeability model with a clear split in the two large zones of moderate chargeability. A  steeply  dipping  fault  has  been  interpreted  at  the  center  of  the  line,  lining  up  with  several  smaller  conductive features in the DC and MT model. In the western side of the line a similar feature is observed  in the MT model, which is also indicated in the model, this feature is too deep to be confirmed by the DC  resistivity model.   The two regions of chargeability are likely formational in origin, with some isolated centers of increased  chargeability.  The  western  half  shows  anomalies  IP‐04  and  IP‐05,  both  located  in  between  two  conductive features in the DC model. The top feature is labelled DC‐05 and has some signature in the  MT model as well. The bottom conductor in the DC model could not be confirmed by the MT model, and  therefore has to be interpreted with great care. Anomaly IP‐04 could be a representation of the Getty  West anomaly.   On the eastern side of the line, anomaly IP‐06 is observed; it is located in between the sub horizontal  conductive  bands  and  a  deep  broken‐up  MT  conductor  (MT‐01);  it  is  likely  the  signature  of  this  conductive  anomaly  is  not  well  resolved  in  the  DC  model  due  to  its  depth.  However,  the  MT  feature  does correlate with a large moderate conductor in the DC model.   Anomalies IP‐04 and IP‐05 correlate well between the DC referenced and the HS referenced IP models  (Figure  3‐8).  Anomaly  IP‐03  on  the  other  hand  has  a  good  lateral  correlation,  but  could  be  located  slightly deeper than indicated in the DC referenced model.      Figure 3‐8: Line 3000N – 2D Half Space referenced IP model.          27 
  • 28. QUANTEC GEOSCIENCE LTD    3.2.6 GETTY NORTH – LINE 3250N    Figure 3‐9: Line 3250N – 2D inversion results.        28 
  • 29. QUANTEC GEOSCIENCE LTD    Line 3250N is not only 250 m to the north but its starting point is also shifted 750 m to the west when  compared to Line 3000N. It does show a similar sub horizontal pattern, especially the MT model. The IP  model shows at least two non‐chargeable breaks in the large, likely formational, moderate chargeable  feature.  On  the  western  side  of  the  model,  anomaly  IP‐05  is  located  at  depth;  it  has  a  moderate  chargeability  signature  and  is  located  in  a  conductor  in  both  the  DC  and  MT  models.  It  could  be  associated  to  the  interpreted  fault  directly  to  the  east  of  IP‐05.  On  the  other  side  of  this  interpreted  fault, the anomaly DC‐06 and the small chargeability anomaly IP‐03 are observed; both are part of one  of  the  sub‐horizontal  features  in  the  MT  model.  In  the  center  of  the  line  moderate‐high  chargeability  anomaly  IP‐04  corresponds  closely  to  the  known  location  of  the  Getty  West  deposit.  The  features  is  located in between  two of the sub‐horizontal feature, and bound on the east  by a narrow conductive  feature  in  the  DC  model,  which  likely  is  another  fault,  but  could  not  be  confirmed  by  the  MT  model.  Approximately 250 m east and at a greater depth (480 m below the surface) a small center of increased  chargeability  (IP‐06)  is  observed  with  a  similar  signature  as  IP‐05  with  relation  to  the  deep  horizontal  feature in the MT model. Again it appears this chargeability anomaly appears to be bound in the east  with a fault, as observed in the MT model (the depth of the fault is too great for the DC model to image  these types of features correctly).           29 
  • 30. QUANTEC GEOSCIENCE LTD    3.2.7 GETTY NORTH – LINE 3500N     Figure 3‐10: Line 3500N – 2D inversion results.        30 
  • 31. QUANTEC GEOSCIENCE LTD    Line  3500N  has  shifted  900  m  to  the  east  relative  to  line  3250N.  Anomaly  IP‐04  associated  with  the  Getty West deposit is now located at the far western side of the model. It has grown slightly in size, but  its  location  has  not  changed  significantly.  Again  a  steeply  dipping  fault  is  identified,  based  on  the  non  chargeable  break  in  the  moderate  formational  chargeability  feature  below  the  non  chargeable,  conductive  overburden.  Also,  the  curved  and  sub  horizontal  features  are  observed  on  this  line.  The  upper feature in which anomaly IP‐04 is located has a more restive nature. The lower feature has a more  conductive nature, especially in the DC model.   Under the eastern half of the line, two major chargeability anomalies IP‐07 and IP‐08 can be observed.  The  location  of  these  features  correlates  very  well  with  the  Getty  North  deposit  which  geophysical  signature  appears  to  be  split  into  two  centers.  The  largest  IP  anomaly  IP‐07  is  located  at  a  depth  of  approximately  300  m  below  the  surface;  the  second  IP  anomaly  IP‐08  is  identified  at  a  more  shallow  depth,  approximately  175  m  below  the  surface.  Both  anomalies  correlate  very  well  with  a  conductive  band in the MT model which , and appear to be split in the DC model by a conductive feature below the  chargeability anomalies (this was also observed on line 750N and 1000N with anomaly DC‐04 separating  anomalies IP‐01 and IP‐02 of the Getty South deposit).           31 
  • 32. QUANTEC GEOSCIENCE LTD    3.2.8 GETTY NORTH – LINE 3750N    Figure 3‐11: Line 3750N – 2D inversion results.          32 
  • 33. QUANTEC GEOSCIENCE LTD    Line  3750  is  shifted  200  m  towards  the  west  from  line  3500N.  It  shows  the  grouped  anomalies  associated  with  Getty  North  (IP‐07  and  IP‐08)  on  the  eastern  side  of  the  line.  The  signature  of  both  anomalies is the largest on this line of the survey area. Anomaly IP‐08 has very high chargeability values  and  is  located  very  close  to  the  surface,  identifying  it  as  the  main  geophysical  target  of  this  survey.  Anomaly IP‐07 also has high chargeability values, but is smaller in size and located at greater depth (270  m  below  the  surface,  in  comparison  to  the  70  m  depth  of  IP‐08  on  this  line).  Again  both  anomalies  appear to be split by a conductive feature in the DC model, located in the middle of the anomalies.   The  DC  and  MT  resistivity  models  show  the  steeply  dipping  faults  and  the  sub‐horizontal,  curved  features.  Both  interpreted  faults  also  are  bounding  features  of  two  weak‐moderate  chargeability  anomalies (IP‐09 and IP‐10). Anomaly IP‐10 could be related to the curved conductor as well as to the  interpreted  fault,  whereas  IP‐09  seems  to  be  associated  with  the  interpreted  fault  only.  The  upper  conductive  band  shows  a  very  small  response  of  the  Getty  West  deposit  (IP‐04).  There  is  a  very  good  correlation between the DC reference IP model and the half space referenced IP model (Figure 3‐12).      Figure 3‐12: Line 3750 N – 2D Half Space referenced IP model.          33 
  • 34. QUANTEC GEOSCIENCE LTD    3.2.9 GETTY NORTH – LINE 4000N    Figure 3‐13: Line 4000N – 2D inversion results.          34 
  • 35. QUANTEC GEOSCIENCE LTD    Line 4000N is centered on the Getty North deposit (IP‐07, IP‐08). Its location is shifted by 500 m towards  the  east  when  compared  to  line  3750N.  This  group  of  anomalies  has  a  very  strong  expression  on  this  line, although the size of both IP‐07 and IP‐08 has reduced. It appears that IP‐08 is a surface feature on  this line, which should be visible in the surface geology. Also IP‐07 is located at a very shallow depth (80  m  below  the  surface).  The  dividing  conductor  observed  in  the  previous  lines  does  not  have  a  clear  signature  on  line  4000N,  but  the  contour  lines  of  the  DC  model  do  suggest  slightly  more  conductive  features in between both anomalies.   The curved, sub horizontal features as the faults are not clearly represented in the models of this line,  likely because of the overall conductive response of the model. A near surface conductor is located in  both the DC and MT models in the eastern edge of the profile. However, it doesn’t have a chargeability  signature, but could be easily tested by geological mapping.          35 
  • 36. QUANTEC GEOSCIENCE LTD    3.2.10 GETTY NORTH – LINE 4250N    Figure 3‐14: Line 4250N – 2D inversion results.          36 
  • 37. QUANTEC GEOSCIENCE LTD    Line  4250N  has  a  similar  extent  to  Line  3750  (i.e.  500  m  further  west  than  line  4000N).  It  shows  only  west side of the Getty North anomalies (IP‐07). It is possible that IP‐09 is observed at this northing as  well, but that part of the line was only covered by current extensions, and no receiving dipoles.  The  conductive  anomaly  DC‐09,  as  the  separating  feature  between  anomalies  IP‐07  and  IP‐08,  is  very  prominent on this line. It also has an expression in the MT model.   A new large chargeable feature IP‐11 is observed on the western side of the line. Its depth below the  surface  makes  it  difficult  to  show  much  detail  for  both  method  and  inversion  algorithm.  However,  its  close  correlation  to  conductive  features  in  the  DC  and  MT  models  do  point  to  an  interesting  target.  Unfortunately due to the staggered line location, there is no nearby line to confirm this anomaly, and it  therefore has to be treated with care.          37 
  • 38. QUANTEC GEOSCIENCE LTD    3.2.11 GETTY NORTH – LINE 4500N    Figure 3‐15: Line 4500N – 2D inversion results.  The location of line 4500N involved another shift of 950 meter towards the east, leaving anomaly IP‐07  on  the  eastern  side  of  the  model.  This  feature,  closely  associated  with  the  Getty  North  deposit,  is  located at a depth around 300 m below the surface on the line, and is the only chargeable feature on  the  line.  Anomaly  IP‐07  appears  to  be  a  chargeable  centre  of  a  large  low‐moderate  formational  chargeability feature, bound on either side by interpreted faults.        38 
  • 39. QUANTEC GEOSCIENCE LTD    3.2.12 GETTY NORTH – LINE 5000N    Figure 3‐16: Line 5000 N – 2D inversion results.  The last line of the survey is Line 5000N, located 500 m north of line 4500N and shifted 250 m to the  west.  No  chargeability  anomalies  are  observed  on  this  line,  apart  from  the  large  formational  feature  bound by the two interpreted faults. Two MT conductors are located on this line (MT‐02 and MT‐03),  which have to be interpreted with care, the depth of these anomalies should implicate a response on  the  DC  model  as  well.  But  this  is  not  the  case.  Additional  lines  to  either  the  north  or  the  south  are  needed to test these features.    39 
  • 40. QUANTEC GEOSCIENCE LTD    3.2.13 PLAN MAP INTERPRETATION  Correlation  of  anomalies  from  line  to  line  can  be  achieved  by  extraction  of  plan  maps  from  the  calculated  section  models.  In  this  fashion  model  values  are  taken  at  a  given  elevation  level  and  the  values are used to create a gridded plan map.   In this report, four elevation levels (1600 m elevation, 1400 m, 1200 m and 1000 m) will be discussed.  Other elevation levels will be presented in the appendix of this report.   The gridding parameters and colour bar legends used in creation of the section maps will be the same  for the plan maps. Also the same annotation for anomalies and geological interpretation will be used.          40 
  • 41. QUANTEC GEOSCIENCE LTD        Figure 3‐17: DC model plan map, 1600 m Elevation.  Figure 3‐18: IP Model plan map, 1600 m elevation.            41 
  • 42. QUANTEC GEOSCIENCE LTD        Figure 3‐19: DC Model plan map, 1400 m elevation.  Figure 3‐20: IP Model plan map, 1400 m elevation.            42 
  • 43. QUANTEC GEOSCIENCE LTD        Figure 3‐21: DC Model plan map, 1200 m elevation.  Figure 3‐22: IP Model plan map, 1200 m elevation.            43 
  • 44. QUANTEC GEOSCIENCE LTD        Figure 3‐23: DC model plan map, 1000 m elevation.  Figure 3‐24: IP Model plan map, 1000 m elevation.          44 
  • 45. QUANTEC GEOSCIENCE LTD        Figure 3‐25: MT model plan map, 1600 m elevation.        Figure 3‐26: MT Model plan map, 1400 m elevation.          45 
  • 46. QUANTEC GEOSCIENCE LTD        Figure 3‐27: MT Model plan map, 1000 m elevation.        Figure 3‐28: MT Model plan map, 600 m elevation.          46 
  • 47. QUANTEC GEOSCIENCE LTD    The circular nature of the Getty North deposit (as depicted in Figure 2‐1) becomes very clear in the 1600  m  plan  maps  (Figure  3‐17,Figure  3‐18  and  Figure  3‐25),  where  anomalies  IP‐07  and  IP‐08  are  merged  into one single chargeability high with two distinct centres. Following these anomalies with depth, the  dual  nature  becomes  more  apparent.  At  greater  depth  only  IP‐07  remains  (see  Figure  3‐22)  as  two  chargeability anomalies to the north and south of the actual occurrence of Getty North at the surface.  The two parts of anomaly IP‐07 follow a more or less NNW‐SSW trend, similar to the interpreted faults  lining up the string of conductors in the DC and MT.  Both Getty  West and Getty South appear as mainly near surface features,  but  can  be  correlated from  line to line very nicely. Anomaly IP‐11 can be identified on line 4250N up to a great depth, but the lack of  coverage to the north and south makes it difficult to verify this anomaly.  At  an  elevation  of  1000  m,  the  DC  and  IP  models  (Figure  3‐23  and  Figure  3‐24)  show  very  smooth  representation of the geology, mainly due to the depth of penetration and the smoothness constraint  use to stabilize the inversion modelling. The MT model is much more sensitive to these greater depth  and still shows sharp images of the interpreted faulting, continuing the NNE‐SSW trend of features up to  the 600 m elevation level.           47 
  • 48. QUANTEC GEOSCIENCE LTD    4 CONCLUSIONS AND RECOMMENDATIONS  A  Titan‐24  DC/IP  and  MT  survey  was  conducted  over  the  Getty  Project,  British  Columbia,  Canada  on  behalf  of  EffiSolar  Energy  Corp.  and  Getty  Copper  Inc.  between  November  20th  and  December  13th  of  2010. In total 12 lines of data were collected (23.2 line‐km DC/IP and 19.2 km MT) with a station spacing  of 100 m. The survey geometry for the DC/IP component was a pole‐dipole geometry. The line spacing  was 250 m and the lines were located in a staggered fashion over three known deposits: Getty North,  Getty West and Getty South.  4.1 RESULTS  The Titan‐24 Survey was successful in identifying the known Getty North, Getty West and Getty South  deposits  as  chargeability  anomalies.  Several  NNE‐SSW  striking  faults  were  identified  as  narrow  conductive features in both the DC and MT models as well as breaks in the chargeability models.  A borehole dataset was made available 6 and plotted as a reference on selected sections. There is a very  good correlation between the boreholes targeting the Getty North and South deposits and the location  of anomalies IP‐07, IP‐08 and IP‐01 respectively (see Figure 4‐1)      Figure 4‐1: 2D IP Inversion results (DC model reference) of line 4000N with borehole  locations overlay (gold assays in grey, copper assays in green).    It appears that the high gold assays observed in the Getty North boreholes (Figure 4‐1) correlate very  closely to the centers of  the  chargeability anomalies, whereas the high copper assays correlate better  with the contact between the high‐moderate chargeability features.                                                               6  Personal communications with Mr. C. Anderson, Getty Copper Inc.     48 
  • 49. QUANTEC GEOSCIENCE LTD      Figure 4‐2: 2D IP Inversion results (DC model reference) of line 750N with borehole  locations overlay (copper assays in red).  For  the  Getty  South  deposit,  the  high  copper  assays  correlate  very  well  with  the  center  of  the  chargeability anomaly, with more potential to depth.        49 
  • 50. QUANTEC GEOSCIENCE LTD        Figure 4‐3: 2D IP results: 1600 m plan map with borehole locations overlay.      50 
  • 51. QUANTEC GEOSCIENCE LTD      Summarizing the results of this survey the following conclusions can be drawn:  • Resistivity  distribution  (DC  &  MT)  show  a  succession  of  curved,  sub‐horizontal  conductive   features and South‐Southwest‐North‐Northeast faulting trend;  • Chargeability signature is fairly weak except for the known deposits and appears to be related to  the interpreted faulting;  • Getty North is likely composed of two centers, where the western center extends further north‐ east in a similar azimuth as the interpreted faults. Resistivity is moderate‐low;  • Getty  West  is  a  near  surface  (<300  m  depth)  feature  of  weak‐moderate  chargeability  &  moderate‐low resistivity;  • Getty South is  a low resistivity, weak‐moderate chargeability feature extending to approx. 350  m below the surface;  • In  total  thirty‐nine  (39)  geophysical  anomalies  were  identified,  of  which  twelve  (12)  are  classified  as  high  priority.  Sixteen  (16)  anomalies  fall  in  the  medium  priority  classification  and  eleven  (11)  are  labeled  as  low  priority.  Prioritization  was  based  on  correlation  between  conductive  and  chargeable  features  and  depth  below  the  surface.  A  complete  overview  of  all  anomalies can be found in the table below.    Anomaly  line  location  depth  DC  IP  MT  priority  remarks  ID  signature  signature  signature  IP‐01  250  2110‐ 110‐ mod  Mod‐low  ‐  2  Partial  2500  480  correlation  with DC‐01  DC‐01  250  2110‐ 130‐ Mod‐low  Mod‐low  ‐  2    26110  480  DC‐02  250  2720‐ 0‐230  mod  low  ‐  3    3030  IP‐01  500  2100‐ 70‐440  Mod‐high  Mod‐ ‐  2  Possible fault  2530  high  DC‐03  500  2590‐ 210‐ Mod=‐low  low  ‐  3    3000  500  IP‐01  750  2100‐ 60‐500  mod  Low‐mod  ‐  2    2380  DC‐04  750  2240‐ 50‐180  Mod‐low  low  ‐  2  Correlation  2420  with top of IP‐ 01  IP‐03  750  2410‐ 40‐250  mod  low  ‐  3  Getty south  2620    51 
  • 52. QUANTEC GEOSCIENCE LTD    Anomaly  line  location  depth  DC  IP  MT  priority  remarks  ID  signature  signature  signature  DC‐05  750  2840‐ 100‐ Mod‐low  low  ‐  3    3210  340  IP‐01  1000  2010‐ 90‐350  Mod‐low  Mod‐ ‐  1  Getty  2190  high  South/Possible  fault  DC‐04?  1000  2150‐ 140‐ Mod‐low  low  ‐  3    24230  410  IP‐03  1000  2280‐ 60‐200  low  Mod‐low  ‐  2  Getty south  2510  DC‐05  1000  2730‐ 30‐300  low  low  ‐  3    3080  IP‐04  3000  39850‐ 150‐ mod  mod  mod  2    40040  410  DC‐06  3000  40020‐ 50‐ low  low  mod  3  Possible sub‐ 40690  2340  horizontal  feature  IP‐05  3000  40320‐ 200‐ mod  Mod0  mod  2    40600  430  MT‐01  3000  40900‐ 290‐ Mod‐low  Mod‐low  low  1    41820  820  IP‐08  3000  41250‐ 290‐ mod  Mod‐;pw  low  2  Correlates well  41720  540  with MT‐01  IP‐04  3250  39390‐  380‐ low  mod  low  1    630  39600  DC‐06  3250  39830‐ 140‐ low  Mod‐low  Mod‐low  2    40060  400  IP‐05  3250  39930‐ 290‐ low  mod  mod  1  Correlates with  40120  450  bottom of DC‐ 05  IP‐07  3250  40290‐ 110‐ mod  Mod‐ Mod‐low  1  Getty West  40500  270  high  IP‐08  3250  40590‐ 480‐ low  low  Mod‐low  3    40710  630  IP‐07  3500  40140‐ 150‐ Mod‐high  mod  high  3  Getty West  40440  350  DC‐07  3500  40520‐ 90‐320  low  low  mod  3      52 
  • 53. QUANTEC GEOSCIENCE LTD    Anomaly  line  location  depth  DC  IP  MT  priority  remarks  ID  signature  signature  signature  40980  IP‐06  3500  41220‐ 260‐ mod  Mod‐ mod  2  Getty North  41630  620  high  IP‐09  3500  41690‐ 180‐ Mod‐low  Mod‐ Mod‐low  2  Getty North  41950  370  high  IP‐10  3750  39850‐ 260‐ Low‐mod  Low‐mod  Low‐mod  2  Possibly  40100  480  associated  with fault  IP‐07  3750  40220‐ 80‐230  Low‐mod  Low‐mod  Low‐mod  1  Getty West  40400  IP‐11  3750  40500‐ 280‐ Low‐mod  Low‐mod  low  2  Possibly  40690  600  associated  with fault  IP‐06  3750  41170‐ 290‐ mod  high  low  1  Getty North  41420  500  IP‐09  3750  41480‐ 80‐420  mod  high  mod  1  Getty North  41870  IP‐06  4000  41310‐ 90‐380  mod  high  mod  1  Getty North  41640  IP‐09  4000  41620‐ 0‐210  Mod‐low  high  mod  1  Getty North  41920  DC‐08  4000  42620‐ 0‐430  low  low  low  3  Possible fault  4300  IP‐12  4250  39960‐ 370‐ Mod‐low  mod  mod  2    40460  840  IP‐06  4250  41540‐ 100‐ Mod‐low  Mod‐ mod  1    41940  530  high  DC‐09  4250  41660‐ 200‐ low  Mod‐ Mod‐low  1  Correlates with  42000  460  high  bottom of IP‐ 06  IP‐06  4500  4147‐ 290‐ mod  Mod‐ mod  2  Chargeable  41980  720  high  center of  formational  anomaly?  Table 3: Geophysical Targets for the Getty Project.        53 
  • 54.
  • 55.
  • 56. QUANTEC GEOSCIENCE LTD        ARRE VERWEERD  I, Arre Verweerd, declare that:  I am a consultant with residence in Toronto, Ontario and am presently employed in this capacity  with Quantec Geoscience Ltd., Toronto, Ontario;  I obtained a Doctorandus Degree (MSc. equivalent) in Geophysics, from the Universiteit Utrecht,  Utrecht,  the  Netherlands  in  2001.    I  also  obtained  a  Doctorate  Degree  in  the  Natural  Sciences  (Dr. Rer. Nat.), subject Applied Geophysics from the Rheinische‐Friedrich‐Wilhelms‐Universität‐ zu‐Bonn, Bonn, Germany in 2007;  I  have  practiced  my  profession  continuously  since  January  2002,  in  Europe,  South  America,  North America, Africa, and Asia.  I  am  a  member  of  the  European  Association  of  Geoscientists  and  Engineers  (EAGE),  the  European  Geosciences  Union  (EGU),  the  Environmental  and  Engineering  Geophysical  Society  (EEGS), the society of Exploration Geophysicists (SEG) and the Canadian Exploration Geophysical  Society (KEGS).   I  have  no  interest,  nor  do  I  expect  to  receive  any  interest  in  the  properties  or  securities  of  EffiSolar Energy Corp./Getty Copper Inc., its subsidiaries or its joint‐venture partners;  I  was  in  charge  of  data  acquisition  quality  control,  I  have  reviewed  the  survey  results  and  can  attest that these accurately and faithfully reflect the data acquired on site; I undertook the 2D  DC/IP  inversions,  I  am  the  author  of  this  interpretation  report  and  have  reviewed  the  appendices.  The  statements  made  in  this  report  represent  my  professional  opinion  in  consideration of the information available to me at the time of writing this report.  Toronto, Ontario  February, 2011            Arre Job Verweerd Dr. Rer. Nat.  Quantec Geoscience Ltd        56 
  • 57. QUANTEC GEOSCIENCE LTD        JASON METCALFE  I, Jason Metcalfe, declare that:  I am a Data Processor with residence in Mississauga, Ontario and am presently employed in this  capacity with Quantec Geoscience Ltd., Toronto, Ontario;  I  obtained  a  Bachelor  of  Science  (B.Sc.)  Geophysics  in  2007  from  the  University  of  Western  Ontario, London, Ontario.  I  have  practiced  my  profession  continuously  since  October,  2009  in  Canada  and  the  United  States;  I  have  no  interest,  nor  do  I  expect  to  receive  any  interest  in  the  properties  or  securities  of  EffiSolar Energy Corp./Getty Copper Inc., its subsidiaries or its joint‐venture partners;  I was the data processor on site, responsible for the quality control of data acquired throughout  the  survey.  I  compiled  and  edited  the  logistics  report.  The  statements  made  in  this  report  represent  my  professional  opinion  based  on  my  consideration  of  the  information  available  to  me at the time of writing this report.  Toronto, Ontario  February, 2010          Jason Metcalfe, B.Sc.  Quantec Geoscience Ltd.      57 
  • 58. QUANTEC GEOSCIENCE LTD    6 DIGITAL ARCHIVE  The CD or DVD attached to this report contains a copy of all the inversion results, final processed data,  including the survey files, the daily processing (and field) notes, and an electronic copy of this report.              58 
  • 59. QUANTEC GEOSCIENCE LTD    A SURVEY LOGISTICS  A.1 ACCESS  Base of Operation:  Copper Valley Motor Inn     Logan Lake     British Columbia  Mode of Access to Grid:  Trucks  Mode of Access to Lines:  Trucks, ATV and Snow mobiles.  A.2 SURVEY GRID AREA  Established by:  Getty Copper  Coordinate Reference System:  Grid referenced to UTM Coordinates  Datum & Projection:  WGS 84 Zone 10U  Grid Azimuth:  90o  Magnetic Declination:  19oE  Station Interval:  100m  Method of Chaining:  GPS and picketing.    Surveyed Line‐start and ‐end point coordinates.  Grid Coordinate  UTM Coordinate Start  UTM Coordinate End  Line  Start  End  Easting  Northing  Easting  Northing  L250N  2000E  3000E  641999  5600250  642974  5600250  L500N  2000E  3000E  642000  5600500  642971  5600516  L750N  2000E  3000E  641997  5600744  642979  5600749  L1000N  2000E  3000E  641993  5600996  642965  5601010  L3000N  39600E  42000E  639601  5602996  641963  5603007  L3250N  39100E  41500E  639121  5603249  641686  5603254  L3500N  40000E  42400E  639998  5603493  642347  5603518  L3750N  39600E  42000E  639676  5603748  642000  5603751  L4000N  40600E  43000E  640629  5603998  642949  5604003  L4250N  39600E  42000E  639598  5604258  641904  5604246  L4500N  41000E  43400E  641020  5604506  643369  5604505  L5000N  41100E  43500E  641096  5604999  643432  5605007      59