1. VIRDI 430FP Fingerprint Authentication Door Lock
Thank you for purchasing Union Community fingerprint recognition
digital door lock. VIRDI 430FP is developed and manufactured by
Union Community Co., Ltd. ISO 9001 and ISO 14001 certified
company, and includes various functions that give convenience
and safety in living. Using leading edge fingerprint recognition
technology, VIRDI 430FP provides the security and
convenience that controls access to your home or office.
■ Please read this user manual carefully for safe and convenient use of the product, and operate
VIRDI 430FP after you completely understand procedures to operate it.
■ We are not liable for any accident or damage caused by not following the user manual properly.
1
IPX4
1
2. Table of Before Using P6~P9 Managing User Fingerprint and Password P20~P42
1.1 Cautionary Items for Safety p6 3.2.7 Registering Remote Control (Optional) p42
Contents 1.2 Items to Check When Entering Fingerprint p8 3.2.8 Deleting Remote Control (Optional) p44
About Product P10~P17 Using VIRDI 430FP (Identical for Both Home and Office Use) P46~P52
2.1 Accessories p10 4.1 Access Using Fingerprint p46
2.2 Parts Name p11 4.2 Access Using Password p47
2.3 Assembly Figure p12 4.3 Access Using Emergency Key p48
2.4 Cautions to Take When Installing VIRDI 430FP p13 4.4 Access When Access Control Is Set p49
2.5 Special Features and Functions of VIRDI 430FP p14 4.5 Opening the Door from Inside p50
4.6 Locking the Door from Inside p51
Managing User Fingerprint and Password P20~P42 4.7 Locking the Door from Outside p52
3.1 For Home Use p20
3.1.1 Registering Fingerprint p20 Additional Functions (Identical for Both Home and Office Use) P54~P70
3.1.2 Deleting Registered Fingerprint p22 5.1 Access Control Setting p54
3.1.3 Registering Password p24 5.2 Canceling Access Control p56
3.1.4 Changing Registered Password p26 5.3 Setting Prohibition on Opening/Closing Button Use p58
3.1.5 Deleting Registered Password p28 5.4 Canceling Prohibition on Opening/Closing Button Use p58
3.1.6 Registering Remote Control (Optional) p28 5.5 Fingerprint Testing p60
3.1.7 Deleting Remote Control (Optional) p30 5.6 Sound Setting p60
3.2 For Office Use p31 5.7 Canceling Intrusion Detection Warning Sound p62
3.2.1 Registering Administrator p32 5.8 Setting Automatic/Manual Locking p62
3.2.2 Registering User p34 5.9 Product Initialization p63
3.2.3 Deleting Registered Administrator or User p34 5.10 Prank Prevention p64
- Deleting by ID p36 Supplement
- Deleting by Fingerprint p38 Summary of Menu Setting (For Home and Office Use) p66
3.2.4 Registering Password p38 FAQ p70
3.2.5 Changing Registered Password p40
4 3.2.6 Deleting Registered Password p42 5
3. Cautionary
Items for Safety
Please read the user manual Warning Caution
carefully before using the
product.
Do not place it near heat Do not let children play Do not expose the Do not impact or shake Do not pour water
sources. with the product. product under direct the product. directly to clean or do
Warning It may cause a fire. It may cause a child accident
sunlight. It may damage the product to cause
not wipe with benzene,
or malfunction of the product. Fingerprint authentication may not malfunction. thinner or alcohol.
When indicated warnings are work properly. It may cause electric
not followed, it may cause a shock, fire.
fatality or serious injury.
Do not assemble, fix or Do not operate the product Do not install product in a Do not let a sharp object Do not use pesticide
Caution modify the product without
authorization.
with wet hand or do not let
the water flow inside the
place where humidity is touch the product. or inflammable
high or there is too much It may cause malfunction.
spray.
When indicated cautions are It may cause malfunction, product. dust.
not followed, it may cause a electric shock or fire. Contact a service It may cause malfunction, It may cause malfunction.
center if a repair service is required. electric shock.
user injury or property
damage.
When replacing the battery, the polarity Carry the emergency key Do not install the product Do not make the We are not liable for
Indicates an item is (+,-) must be observed. with you at all times or in a place where Fingerprint Input any accident or
prohibited If the polarity of the battery is wrong, it may
place it in a safe place. temperature variation is window dirty. damage caused by
cause malfunction, fire due to explosion or leakage large. Fingerprint may not be recognized
not following the
Indicates an item inside of the battery. Do not mix and use new It may cause malfunction. properly. procedures in the
must be followed. battery with old battery. user manual.
6 7
4. Items to Check Items to Check
When Entering ¡ Proper way to enter fingerprint ¡ Cautions to take according to fingerprint condition When Entering
Using index finger, enter your finger print as if you are printing handstamp. Depending on the fingerprint condition, it may not be possible to use or it may be
Fingerprint Touching the edge of the finger is not a proper way to register or enter. inconvenient to use it. Fingerprint
Touch the fingerprint center to the fingerprint input window. ▶This product operates by recognizing fingerprint, operated it with password if the
fingerprint is not useable due to damaged or weak fingerprint.
▶When the finger is wet, blow a breath over the fingerprint for a proper operation
of the product.
▶Child’s fingerprint may be difficult or impossible to be used due to its small size or
weakness. Child’s fingerprint should be reregistered every 6 months.
▶It may not be possible to register senior citizen’s fingerprint if fingerprint has
excessive fine wrinkles.
¡ Check if your fingerprint is not clear or has a scar.
▶It may be convenient to register 2~3 fingerprints simultaneously if fingerprint is weak.
Too dry, humid, unclear or scarred fingerprint may be difficult to be recognized.
If it occurs, use another finger to register. ▶Registering more than 2 fingerprints is recommended.
8 9
5. Inside Unit Body Flat Head Screw
F+M5x20mm (2EA)
Accessories Inside Unit Body Round Head Screw
O+M5x40mm (2EA)
Parts Name
Strike Flat Head Screw Inside Unit Body Outside Unit Body
(small F+U10-24x10mm) (2EA)
Mortise Lock Flat Head Screw Battery Cover
(small F+U10-24x10mm) (2EA)
Outside Unit Handle Connecting Set
Screw M6x8mm (1EA)
Inside Unit Body Outside Unit Body Inside Unit Outside Unit Mortise Lock Outside Unit Handle
Rubber Band Rubber Band Battery Insertion Location (8EA)
Keypad
Hex Wrench
AA Battery (8EA) Emergency Key (3EA) Inside Unit Handle Automatic/Manual Conversion Switch
Fingerprint Button
Password Button Fingerprint Input Window
Hand Ring (2EA
Strike Box Strike Latch Bolt Menu Button
Switching Pin Cover Opening Button
Opening/Closing Button
(Authentication Button)
430FP
LED Status Display
Window
Manual Opening/Locking Lever
(Opening/Locking)
User Manual AA Battery Remote
(2EA, Optional) Control Inside Unit Handle Outside Unit Handle
(Optional)
Installation Template Installation Procedures Emergency Key
(Both Left, Right Hand Insertion Hole
10 Side Door) Emergency 11
Power Source
6. Assembly Cautionary Items
Door
Figure during Installation
Outside Unit Body
Battery Cover
▶This product is a fingerprint recognition digital door lock that is installed at the entrance door.
Inside Unit Body (Main key type)
▶This product can not be installed on a strengthening glass door.
Doorframe ▶If a gap is created due to high degree of bending of the installation surface, we advise you not to
install the product for safety reason.
▶The installation of the product is not possible if an installation space is not sufficiently provided
Outside Unit Handle
such as in chassis quality entrance door.
Handling Inside Unit ▶The installation is not possible if the inside and outside of the door is exposed like such as main gate.
Fixing Screw
Key Tail Shaft ▶The installation is possible on a wooden door but a user caution is required as it has low hardness
Inside Unit Handle
Strike ▶For a door opening on both right and left side, install the product only after fixing one side of the door.
Strike Fixing Screw ▶Before installing the product, it must be considered that punched holes can not be returned to their
Mounting Shaft
original state when the product is removed from the door because of moving or other reasons.
Inside
Unit Handling ▶Even when another person including service man installs the product, register the password yourself
Set
Fixing to prevent password exposure. We are not liable for damage caused by password exposure.
Screw
Screw
▶During first time installation, make sure that Door Open mode (Manual Locking) is set before you
Lock Case install the product and register a fingerprint.
(Mortise)
Strike Box Strike Cover Lock Case Hex Wrench
Screw Fixing Screw
Door Open Mode (Manual Locking)
12 13
7. Special Special
Features and ¡ The number of registrable fingerprints ¡ Automatic Cover Opening/Closing Features and
The cover can be opened and closed automatically using the Cover Opening button.
Functions For Home Use Mode For Office Use Mode
¡ Function to Prohibit Opening/Closing Button Use Functions
Master: 5 fingerprints
30 fingerprints This function is used during sleep or in other occasions to prevent an intrusion.
User: 25 fingerprints
When you try to register fingerprints exceeding the upper limit, the process
¡ Keypad Backlight Function
Using a high resolution LED, the number buttons of the keypad can be easily
ends after a “beerip” sound is heard.
distinguished at night.
¡ Conversion between Home Use and Office Use ¡ Password and User Fingerprint Storage Function
Conversion between home use and office use mode of this product is easy and convenient. The previously registered fingerprint and password are not erased after the
•During mode conversion, the terminal information will be initialized. battery is replaced.
Your attention is required as all the information will be erased.
¡ Door Opening Check Function
[Mode Conversion Procedures] After a successful authentication or pressing the Opening/Closing button from inside, it
¡ Press the Fingerprint and Password button of the inside terminal for longer than 3 seconds. will return to the locking state if the door is not opened within 10 seconds. To close the
After buzzer sounds “beep”,“beerip” are heard, enter the information following the procedures below. door immediately from outside, push the Cover Opening button once again.
This function operates regardless of the state of Automatic/Manual conversion switch.
¡ One way to tell the difference between home and office use mode is that ¡ Door Open (Manual Locking) Function
briefly pressing the Fingerprint button will let the cover slide up to reveal the To open the door at all times, select the ‘Manual’ switch and leave the door open.
keypad and turn the LED keypad on after a “beep” sound in office use mode. Then, access is possible without fingerprint or password authentication every time.
In home use mode, briefly pressing the Fingerprint button will let the cover
•This function may be convenient but an intrusion may occur.
slide up to reveal the Fingerprint sensor after a “beep” sound.
•It is recommended to use ‘Automatic’ mode in the
[The Special Features of Office Use Mode] Automatic/Manual Conversion switch.
•The administrator and the user are divided. •When Manual mode is set, press the Cover Opening button to
•Once an administrator is registered, only the administrator can set up or lock the door from outside.
manage the terminal. Door Open Mode (Manual Locking)
14 •Registering and deleting users using ID 15
8. Special Special
¡ Battery Replacement Notice Function ¡ Battery Replacement
Features and When opening the door using fingerprint or password, a warning sound (“beep beep beep Check if the batteries (8 Alkaline 1.5V AA type) are included after purchase and insert
Features and
Functions beep ~~~”) indicates that the battery needs to be replaced. Replace the battery within a
week after the first warning sound is heard.
them checking the proper (+,-) direction.
•If the voltage falls below the reference voltage, the red LED light on the LED status display
Functions
•Since the battery discharges naturally after a long period of time, it is recommended to window will blink and a warning sound (“beep beep beep…”) will be heard during
purchase newly manufactured batteries. authentication. After lifting the cover of the Inside Unit, separate the cover and change
•The battery life may differ depending on manufacturer, date of manufacture or use and the battery.
system environment. •Access is not possible if the battery is completely discharged. Enter using the emergency
•After batter replacement warning sound is heard, registering and deleting function can key and replace the battery.
not be accomplished.
¡ Battery Replacement Period
¡ External Power Supply The battery life is over 12 months on a basis of 20 times use per day with 8 AA 1.5V
When the battery replacement time is passed, the door can not be opened using fingerprint batteries. When the remote control is used, the battery life becomes over 9 months.
or password. The door needs to be opened using the emergency key. If the emergency
key is lost or is not in your possession, the door starts operating by contacting a 9V battery ¡ Cautionary items when using the product
(6LF22) to the input terminal of external power source. •Inserting battery with wrong polarity may cause a battery liquid leakage or explosion.
¡ Intrusion Detection Warning Sound •When replacing the battery, replace all batteries simultaneously. Do not mix and use old
battery with new battery.
An intrusion will make a warning sound (loud beep) for 5 minutes.
•During fire prevention test, the temperature sensor operates around 50¡
¡ Fire Alarm Detection Sensor (sensor operating temperature: approximately 50 ¡ ). The sensor operating temperature
In case of fire, a warning sound (loud beep) will be heard and the door will open automatically. varies depending on the use and environment.
¡ Access Using Password during Initialization •Rated Voltage : DC 6V
Make access using the initial password in the following cases.
•After purchase/On initializing the terminal/When no registered fingerprint is available and
password was deleted.
Door access procedure
using the initial password +
•The initial password will be erased after a fingerprint or password is registered.
¡ÿChange the password after the installation.
16 17
9. Managing User Fingerprint and
Password
This section is divided into two parts : for home use and office use.
10. For Home
Use 3.1.1 Registering Fingerprint
¡ The user registration follows the procedures below. If no previous registered user is
available, skip the step 3 (Authentication of registered user).
1 “beep”
2 “beeriririp”
3 “beeririp”, “beeriririp”
4 “beeriririp”
5 6
If successful : “beeririp”
If failed : “beerip”
After separating the battery The cover slides up to When the red light is turned When the red light is turned After a long beep tone, The cover slides up to reveal
cover of Inside Unit Body, reveal the Fingerprint on in the Fingerprint Input on at the Fingerprint Input when the red light is turned the keypad, and the light is
press the Fingerprint button. Input window. window, enter a registered window, enter a fingerprint on, enter the same turned on in the keypad.
fingerprint. If no registered to be registered. fingerprint again. • : End
¡fi*¡fl
fingerprint is available, the • : Additional Registration
¡fi#¡fl
¡ Additional Fingerprint Registration step 3 is skipped.
•Enter a fingerprint after reading ‘Items to check’ on page 8.
7 “beeriririp”
8 “beeriririp”
9 10 •When entering a user fingerprint, it requires to enter twice.
•During fingerprint input process, if a fingerprint is not entered or
If successful : “beeririp”
the same finger print is not entered, the process ends with a
If failed : “beerip”
registration failure buzzer sound (“beerip”).
•Check if your fingerprint is in good condition or it is not dirty or
Press the ‘#’ button. When the red light is After a “beeriririp” sound, The light is turned on in the keypad. dry before registering.
turned on in the when the red light is turned • : End
¡fi*¡fl •If registering fingerprint process fails, retry it after blowing a
Fingerprint Input window, on in the Fingerprint Input • : Additional Registration
¡fi#¡fl breath over the fingerprint.
enter a fingerprint to be window, enter the same
additionally registered for fingerprint again.
20 about 2 seconds. 21
11. For Home
Use 3.1.2 Deleting Registered User
1 “beep”, “beerip”
2 “beeriririp”
3 4 Additional 5 “beeriririp”
6 7
If successful : “beeririp” Deletion If successful : “beeririp”
If failed : “beerip” If failed : “beerip”
After separating the The cover slides up to When the red light is The cover slides up to reveal Press the ‘#’ button. When the red light is
battery cover of Inside reveal the Fingerprint turned on in the the keypad, and the light is turned on in the
Unit Body, press the Input window. Fingerprint Input window, turned on in the keypad. Fingerprint Input window,
Fingerprint button for enter the fingerprint to be • : End
¡fi*¡fl enter the fingerprint to be
longer than 3 seconds. deleted. • : Additional Registration
¡fi#¡fl deleted.
•After completion, the cover will automatically be closed without a
further action.
•Before deleting, check if your fingerprint is in good condition or it
is not dirty or dry.
•If deleting fingerprint process fails, retry it after blowing a breath
over the fingerprint.
22 23
12. For Home
Use 3.1.3 Registering Password
¡ This describes steps to register a password.
Once a password is registered, access without using fingerprint is possible.
1 “beep”
2 “beeriririp”
3 “beeriririp”
4 5
If successful : “beeririp”
£« £« If failed : “beerip” (End)
After separating the battery The cover slides up to When the light is turned on in the After a “beeriririp” sound, press
cover of Inside Unit Body, reveal the keypad. keypad, enter a password and the same password and ‘*’
press the Password button. then press ‘*’ button. button in sequence.
•One password can be designated for use.
(Each user can not have its own password.)
•It is recommended to change the password periodically or
frequently for security reason.
•The password can have between 4 and 20 digits. It is
recommended to use more than 8 digits for security reason.
•The initial password (00000) is not considered as a registered
password.
•If the process of registering password fails, a buzzer sound
(“beerip”) is heard and the setting process ends.
• If you need to end the process during password registration,
press button simultaneously.
24 25
13. For Home
Use 3.1.4 Changing Registered Password
¡ Password change is possible when a password is registered in the terminal.
See page 24 on procedures to register a new password.
1 “beep”
2 “beeriririp”
3 “beeririp”, “beeriririp”
4 “beeriririp”
5 6
If successful : “beeririp”
£« £« £« If failed : “beerip” (End)
After separating the battery The cover slides up to When the light is on in the keypad, Enter a new password and After a “beeriririp” sound, reenter
cover of Inside Unit Body, reveal the keypad. enter the registered password and press the ‘*’ button. the new password and
press the Password button. press the ‘*’ button. ‘*’ button in sequence.
•Change the password periodically or frequently for security
reason.
•The password can have between 4 and 20 digits. It is
recommended to use more than 8 digits for security reason.
•If the process of changing password fails, a buzzer sound
(“beeriririp”) is heard and the setting process ends.
26 27
14. For Home
Use 3.1.5 Deleting Registered Password
1 “beep”, “beerip”
2 “beeriririp”
3 4
If successful : “beeririp”
£« If failed : “beerip” (End)
After separating the battery The cover slides up to After the light is turned on in the
cover of Inside Unit Body, reveal the keypad. keypad, enter the password to
press the Password button for be deleted and ‘*’ in sequence.
longer than 3 seconds.
3.1.6 Registering Remote Control (Optional)
¡ Up to 2 remote controls can be registered. To register 2 remote controls, purchase an additional one.
1 “beep”, “beerip”
2 “beeriririp”
3 “beeririp”
4 5
If successful : “beeririp”
£« If failed : “beerip” (End)
After separating the battery The cover slides up to Press ‘0,1,4,7,2,3,5,9’ + ‘#’ When the blue LED light is If the process fails,
cover of Inside Unit Body, press reveal the keypad. button In sequence. turned on in Outside Unit start over from step 1.
the Password and Fingerprint Body, press the button in
button simultaneously for the remote control.
28 longer than 3 seconds. 29
15. For Home
Use 3.1.7 Deleting Remote Control (Optional)
¡ Up to 2 remote controls can be registered. To register 2 remote controls,
purchase an additional one. ‘For Office Use’
1 2 3
With the administrator and user divided, only the
administrator can set up and manage the terminal
“beep”, “beerip” “beeriririp” after an administrator is registered.
£«
•Administrator fingerprint : 5, general user fingerprint : 25
After separating the battery The cover slides up to Press ‘0,9,5,3,2,7,4,1’ + ‘#’
cover of Inside Unit Body, reveal the keypad. button in sequence. •It is possible to register and delete a user using ID.
press the Password and
Fingerprint button •Your attention is required because all the information will be erased due to the
simultaneously for longer terminal initialization during mode conversion.
than 3 seconds.
•For mode conversion, follow the procedures below:
•After pressing the Fingerprint and Password button of Inside Unit Body for longer
4 than 3 seconds, enter the information following the procedures below when a
buzzer sound (“beep”,”beerip”) is heard and the cover slides up to reveal the
If successful : “beeririp” keypad.
If failed : “beerip” (End)
•If successful : “beeririp”, if failed : “beerip”
If the process fails, start
again from step 1. •The mode conversion process carries out the same functions as the
entire initialization.
30
16. For Office
Use 3.2.1 Registering Administrator
¡ The process of registering an administrator proceeds according to the procedures
below. If no registered administrator is available, step 4 (fingerprint authentication of
registered administrator) is skipped.
1 “beep”
2 “beeriririp”
3 “beeriririp”
4 “beririp”
5 “beeriririp”
6 “beeriririp”
7 8
“beeriririp” If successful : “beeririp”
If failed : “beerip”
After separating the The cover slides up to Press the ‘6’ button. When the red light is turned on Enter a 2-digit ID to be When the red light is turned After a “beeriririp” The light is turned
battery cover of Inside reveal the keypad. in the Fingerprint Input window, used by the administrator on in the Fingerprint Input sound, enter the in the keypad.
Unit Body, press the enter a registered administrator’s to be registered. window, enter a fingerprint of same fingerprint • : End
¡fi*¡fl
Fingerprint button. fingerprint. If no registered •If an ID is not entered within 5 the administrator to be when the red • : Additional
¡fi#¡fl
administrator is available, the seconds, a buzzer sound (“beerip”) is registered. light is turned on. Registration
heard and the process ends.
¡ Registering Additional Fingerprint of the Administrator step ‘4’ is skipped.
•Up to 5 administrator can be registered.
9 “beeriririp”
10 “beeriririp”
11 “beeriririp
12 13 •During fingerprint registration, it is required to enter the same
fingerprint twice after entering a 2-digit ID.
If successful : “beeririp” •During fingerprint registration, if a fingerprint is not entered or the
If failed : “beerip” same fingerprint is not entered, a buzzer sound (“beerip”)
indicating fingerprint registration failure is heard and the
process ends.
Press the ‘#’ button. Enter a 2-digit ID to be used by When the red light is turned After a “beeriririp” sound, The light is turned on
• If an identical ID to a previously registered ID is entered,
an administrator to be on in the Fingerprint Input enter the same in the keypad. a buzzer sound (“beerip”) is heard and the process ends.
additionally registered. window, enter a fingerprint of fingerprint when the • : End
¡fi*¡fl
•If a fingerprint registration process fails, blow a breath over the
•If an ID is not entered within 5 the administrator to be red light is turned on. • : Additional Registration
¡fi#¡fl
seconds, a buzzer sound (“beerip”) is fingerprint and retry it.
additionally registered.
heard and the process ends.
32 33
17. For Office
Use 3.2.2 Registering User
¡ The process of registering a user proceeds according to the procedures below. If no
registered user is available, the step 4 (fingerprint authentication of a registered user) is skipped.
1 “beep”
2 “beeriririp”
3 “beeriririp”
4 “beririp”
5 “beeriririp”
6 “beeriririp”
7 8
“beeriririp” If successful : “beeririp”
If failed : “beerip”
After separating the The cover slides up to Press the ‘1’ button. When the red light is turned on Enter a 2-digit ID to be When the red light is After a “beeriririp” The light is turned
battery cover of Inside reveal the keypad. in the Fingerprint Input window, used by the administrator turned on in the sound, enter the in the keypad.
Unit Body, press the enter a registered administrator’s to be registered. Fingerprint Input same fingerprint • : End
¡fi*¡fl
Fingerprint button. fingerprint. If no registered •If an ID is not entered within 5 window, enter a fingerprint when the red light is • : Additional
¡fi#¡fl
administrator is available, the seconds, a buzzer sound (“beerip”) of the administrator turned on. Registration
is heard and the process ends.
¡ Registering an additional user fingerprint step ‘4’ is skipped. to be registered.
9 “beeriririp”
10 “beeriririp”
11 “beeriririp”
12 13 •During fingerprint registration, it is required to enter the same
fingerprint twice after entering a 2-digit ID.
If successful : “beeririp” •During fingerprint registration, if a fingerprint is not entered or the
If failed : “beerip” same fingerprint is not entered, a buzzer sound (“beerip”)
indicating fingerprint registration failure is heard and the
process ends.
Press the ‘#’ button. Enter a 2-digit ID to be used by When the red light is turned After a “beeriririp” sound, The light is turned in the •If an identical ID to a previously registered ID is entered,
a user to be additionally on in the Fingerprint Input enter the same keypad. a buzzer sound (“beerip”) is heard and the process ends.
registered. window, enter the fingerprint fingerprint when the • : End
¡fi*¡fl •If a fingerprint registration process fails, blow a breath over the
•If an ID is not entered within 5 of the user to be additionally red light is turned on. • : Additional Registration
¡fi#¡fl fingerprint and retry it.
seconds, a buzzer sound (“beerip”) is registered.
heard and the process ends.
34 35
18. For Office
Use 3.2.3 Deleting Registered Administrator or User (Using ID)
1 “beep”
2 “beeriririp”
3 “beeriririp”
4 “beeririp”, “beeriririp”
5 6
If successful : “beeririp”
If failed : “beerip”
After separating the The cover slides up to Press the ‘3’ button. When the red light is Enter a 2-digit ID to The light is turned in
battery cover of Inside reveal the keypad. turned on in the be deleted. the keypad.
Unit Body, press the Fingerprint Input window, •If an ID is not entered within 5 • : End
¡fi*¡fl
Fingerprint button. enter a registered seconds, a buzzer sound (“beerip”) is •
¡fi#¡fl Additional Registration
:
heard and the process ends.
administrator’s fingerprint.
¡ Deleting an additional ID
7 “beeriririp”
8 9
If successful : “beeririp”
If failed : “beerip”
Press the ‘#’ button. Enter a 2-digit ID to be deleted. The light is turned in the
•If an ID is not entered within 5 keypad.
seconds, a buzzer sound (“beerip”) is • : End
¡fi*¡fl
heard and the process ends.
• : Additional Registration
¡fi#¡fl
36 37
19. For Office 3.2.3 Deleting Registered Administrator or User
Use (Using Fingerprint)
1 “beep”
2 “beeriririp”
3 “beeriririp”
4 5 Additional 6 “beeriririp”
7 8
If successful : “beeririp” Deletion If successful : “beeririp”
If failed : “beerip” If failed : “beerip”
After separating the The cover slides up to Press the ‘2’ button. When the red light is The light is turned on Press ‘#’ button. When the red light is
battery cover of Inside reveal the keypad. turned on in the in the keypad. turned on in the
Unit Body, press the Fingerprint Input window, • : End (“beeririp”)
¡fi*¡fl Fingerprint Input window,
Fingerprint button. enter a fingerprint to be • : Additional Deletion
¡fi#¡fl enter a fingerprint
deleted. to be deleted.
3.2.4 Registering Password
¡ This describes procedures to register a password.
Once the password is registered, access is possible without using a fingerprint.
1 “beep”
2 “beeriririp”
3 “beeriririp”
4 “beeriririp”
5 6
If successful : “beeririp”
£« £« If failed : “beerip”
Press the Password The cover slides up to Press the ‘4’ button. Enter a password to be used and After a “beeriririp” sound,
button of Inside reveal the keypad. press the ‘*’ button. reenter the same password
Unit Body. •If a password is not entered within 5 and press ‘*’ button.
seconds, a buzzer sound (“beerip”) is
heard and the process ends.
38 39
20. For Office
Use 3.2.5 Changing Registered Password
¡ The process of changing the password is possible when a password is registered.
(See page 38)
1 “beep”
2 “beeriririp”
3 “beeriririp”
4 “beeririp”, “beeriririp”
5 “beeriririp”
£« £«
After separating the battery The cover slides up to Press the ‘4’ button. Enter a registered password Enter a new password and
cover of Inside Unit Body, reveal the keypad. and press the ‘*’ button. press the ‘*’ button.
press the Fingerprint button. •If a password is not entered within 5 •If there is no input within 5 seconds,
seconds, a buzzer sound (“beerip”) is a buzzer sound (“beerip”) is heard
heard and the process ends. and the process ends.
•One password can be designated for use.
6 7
(Each user can not have its own password.)
•It is recommended to change the password periodically or
If successful : “beeririp” frequently for security reason.
£« If failed : “beerip” (End) •The password can have between 4 and 20 digits.
It is recommended to use more than 8 digits for security reason.
•The initial password (00000) is not considered as a
After a “beeriririp” sound, registered password.
enter the same number again •If the process of registering password fails, a buzzer sound
and press the ‘*’ button. (“beerip”) is heard and the process ends.
• If you need to end the process during process, press
button simultaneously.
40 41
21. For Office 3.2.6 Deleting Registered Password
Use ¡ The process of deleting password is possible when a password is registered. (See page 38)
1 “beep”
2 “beeriririp”
3 “beeriririp”
4 5
If successful : “beeririp”
£« If failed : “beerip” (End)
After separating the battery The cover slides up to Press the ‘5’ button. Enter a registered password
cover of Inside Unit Body, reveal the keypad. and press the ‘*’ button.
press the Fingerprint button. •If a password is not entered within 5
seconds, a buzzer sound (“beerip”) is
heard and the process ends.
3.2.7 Registering Remote Control (Optional)
¡ Up to 2 remote controls can be registered. To register 2 remote controls,
purchase an additional one.
1 “beep”, “beerip”
2 “beeriririp”
3 “beeririp”
4 5
If successful : “beeririp”
£« If failed : “beerip” (End)
After separating the battery The cover slides up to Press ‘0, 1, 4, 7, 2, 3, 5, 9’ + ‘#’ When the blue LED light If the process fails,
cover of Inside Unit Body, press reveal the keypad. button. of Outside Unit Body is start over from step 1.
the Password and Fingerprint turned on, press the
button simultaneously for longer remote control button.
42 than 3 seconds. 43