SlideShare ist ein Scribd-Unternehmen logo
1 von 72
9. Abutment selection


              John Beumer III DDS, MS
                  George Perri DDS
 Division of Advanced Prosthodontics, Biomaterials and
              Hospital Dentistry, UCLA
This program of instruction is protected by copyright ©. No portion of
this program of instruction may be reproduced, recorded or transferred
by any means electronic, digital, photographic, mechanical etc., or by
any information storage or retrieval system, without prior permission.
Restoration connection to abutment
       and/or implant fixture
      Biologic and technical issues
       v    Screw retained systems
       v    Cement retained systems
       v    Screwless - cementless system (UCLA II)
       v    Platform reduction (ie platform switching)
Arguments commonly
                   used in favor of cementation
v  It’s
      a common procedure in the dental office: No
   “Implant” knowledge necessary?
    v    Implants for dummies
v  The screw access hole is through the labial or buccal
     v  Other options - Lingual set screws-lab expense and lab expertise

v  Simple       traditional impression techniques?
    v    Packing gingival retraction cord vs screw retained impression copings
v  Better esthetics?
    v  Permits the use of zirconium abutments. Predictability of Zirconium
        abutments?
v  Fit   isn’t as critical
    v    Really? The assumption is that a misfit is just a passive cement gap
          with no negative consequences
Major Problems
v Cement accumulation
v Lack of retrievability
Subgingival cement accumulation




Prepable abutment
    These abutments can be prepared at the lab bench or
    intraorally. An impression is made and the restoration
    is cemented in the usual and customary fashion.
Subgingival cement accumulation




Prepable abutment
    An impression was obtained with an impression coping
    and the prepable abutment was attached to the fixture
    analogue imbedded in the master cast.
Subgingival cement accumulation




Prepable abutment
v The abutment is prepared so that the margin is slightly sub gingival.
v An impression is made and the porcelain fused to metal crown was
        completed in a customary fashion.
v The abutment is secured to the implant fixture and the crown is then
        cemented.
Subgingival cement accumulation




Prepable abutment
v The patient was unhappy with the esthetic result and so a
hole was drilled into the occlusal surface in order to access the
abutment screw. The crown and abutment was then removed
v Note the accumulation of cement subgingivally.
Subgingival cement accumulation
                                                   Sulcus    Epithelium




                                 Implant Surface
Why is there a greater risk of
cement accumulation in the
sulcus of implant crowns?


Peri-implant
tissues are
more easily
displaced from
                                                       Circumferential
the surface of
                                                       collagen fibers
the restoration.

                                                    Bone


                   *
Anatomy & Biology
                     of Peri-Implant Soft Tissue
Similarities between
periodontal & peri-implant
  soft tissues:
v    Oral epithelium
v    Sulcular epithelium
v    Junctional epithelium

Differences in peri-implant
soft tissues include:
v    Lack of CT attachment
v    Hypovascular,
      hypocellular CT zone adjacent
      to the implant
v    Absence of periodontal
      ligament blood supply

                                         Sclar AG, 2003
Cementation permits use
                        of a ceramic abutment
                             Excellent esthetic result




v    Subgingival cement accumulation can be limited by packing gingival
      retraction cord prior to cementation
v    Allows the creation of an all ceramic restoration from the implant to
      the incisal edge. Is there an esthetic advantage? Perhaps.
v    The main issue is positioning of the cement margin
v    Incidence of fracture of zirconium abutments is a concern but long
      term followup data is not yet available.
Preformed nonprepable abutments
Issues of concern
 v  Positionof the cement margin in
   relation to the gingival margin
    v Particularly   significant in the anterior region
 v  Impaction   of cement into the gingival
    sulcus
 v  Difficulty in seating the crown because
    of hydraulic pressure
Preformed nonprepable abutments




Considerations for use:
v Tissue height essentially the same 360 degrees around the
        abutment
v Head of the implant or abutment cement margin just subgingival
v Sufficient clearance for sufficient axial wall height for predictable
        cement retention
v Angulation allows reasonable draw with adjacent teeth
Preformed
          nonprepable abutments




v  The margin between the crown and the
    abutment does not follow the gingival margin.
v  There is significant risk of trapping cement
    beneath the gingival tissues upon cementation.
Preformed nonprepable abutments
    This patient presented with severe peri-implantitis 3 years
                     post insertion of the crown.

 The initial x-ray                                A subsequent
 appeared to                                      x-ray, taken at
 indicate that the                                right angles to
 crown was                                        the long axis of
 seated.                                          the implant,
                                                  revealed that
                                                  the crown, was
                                                  not seated.

Inability to completely seat the crown onto the abutment is a
common complication associated with preformed abutments.
Lingual access holes may help relieve the hydraulic pressure and
enable seating of the crown.
Preformed nonprepable abutments




Note the inflammation
associated with the peri-
implant gingiva 2 1/2
years post insertion.
UCLA Abutment
 Indications:
 a)    Lack of interocclusal space
 b)    Restorations in the esthetic zone
 c)    Angulation problems
 d)    Soft tissue problems
UCLA Abutment Technique
Ucla Abutment Technique
Custom abutments with screw
         retained restorations
                Advantages
                  v    Control thickness
                        of labial porcelain
                  v    Used when the
Waxing                  implant is inclined
sleeve                  excessively to the
                        labial.
                  v    Retrievable

                Full contour wax
                pattern is developed
Custom abutments with
        screw retained restorations

   Wax cut back
                                  Sprued
                                  wax
                                  pattern




Lingual retention screw channel
Custom abutments with screw
               retained restorations


Cast
custom
abutment




               Note lingual retention screw orifice
Custom abutments with screw
         retained restorations
Coping


                        Completed and
                        sprued wax pattern




 Lingual retention
 screw channel        Labial index
                      fabricated following
                      the full contour wax
                      pattern.
Custom abutments with screw
    retained restorations

                   Completed
                   crown
                         Retention
                         screw
                 Abutment
                 screw


                  Custom
                  abutment
Custom abutments with screw
             retained restorations



                      Completed
                       restoration
    Lingual
retention screw
Custom abutments with screw
    retained restorations
Custom abutments with screw
       retained restorations




 Healing              Full contour
 abutment             wax pattern




                    Completed
Wax pattern of      custom abutment
custom abutment
Custom abutments with screw
    retained restorations




              Completed
              restoration.
              Note the level of
              the gingiva
Custom abutments with screw
    retained restorations




                Gingival levels do
                not match but the
                the patient does
                not display his
                gingiva during a
                high smile.
Custom abutments allows
             the use of pink porcelain




Porcelain has been baked onto the custom abutment
Custom abutments with
screw retained restorations
Excessive labial inclinations


           The axial wall lengths are
           frequently inadequate for
           effective cement retention
Custom abutments with
                 screw retained restorations




Labial axial walls are insufficient to retain a cemented restoration.
Custom abutments with
screw retained restorations
Custom abutments with screw retained
           restorations
Limits of Cement Retention
Implants angled excessively to the labial or
  buccal
  v  Axialwall height limits the retention
  v  Shortest wall determines retention
  v  Minimum height of axial wall – 4 mm.
Fit isn’t as critical ?
Really? The assumption is that a misfit is just a passive
cement gap with no negative consequences




                                The restoration appears
                                to precisely fit the
                                master cast. However,
                                will it fit the patient?
Fit isn’t as critical ?
 Really? The assumption is that a misfit is just a
 passive cement gap with no negative consequences




Unfortunately, this was not the case. If you cement this case
there will be a sizable cement margin and you may overload the
implants.
Fit isn’t as critical ?
Really? The assumption is that a misfit is just a passive cement
gap with no negative consequences




                          When the impression is made
                          with linked open tray
                          impression copings and the
                          original restoration placed on
                          the master cast the misfit is
                          profound
Fit isn’t as critical ?
Really? The assumption is that a misfit is just a passive
cement gap with no negative consequences




 New Bridge on accurate model.
Emergence Profile Compromises
                   Screw vs Cement Retained
v    Cemented crown contour            v  Screw retained crown
      begins ideally just apical to the     can carry ideal contour
      marginal soft tissue, which can
                                            all the way to the head
      produce the classic “pancake”
      crown.                                of the implant (arrow)
Summary: Limits of Cement Retention
 v  Axialwall height limits the retention
 v  Shortest wall determines retention
 v  Minimum height – 4 mm.
Cementation




The main issues are:
  v  Cement retention (pack retraction chord before cementation)
  v  Quality of retention (axial wall length)
  v  Lack of retrievability
Arguments in favor of screw retained restorations
v    Carry restoration more subgingivally than we can
      predictably remove cement.
      v  Formore ideal emergence profile and contour.
      v  Avoid trapping cement subgingivally

v    More predictable seating of bridge pontic or even
      single tooth given the gingival contour.
v    Better retention particularly when a cemented
      restoration would have a very short axial wall.
v    Easier to restore when there is limited inter-
      occlusal or restorative space
Next Generation of the UCLA Abutment
       Shape Memory Sleeve (Seo               and Wu)




❖  The treatment procedure is similar to current methods
The Next Generation of the UCLA
          Abutment
           Shape Memory Sleeve




                   “Nitinol”
               (Nickel titanium alloy)
Next Generation of the UCLA Abutment
                (Seo and Wu)
Issues
  v Is Nitinal biocompatible?
  v Will the increase in temperature during
     activation be transmitted to the fixture,
     abutment and underlying tissues?
  v What is the quality of the retention?
  v Will it stand up to repeated occlusal
     loading
  v Galvanic reactions?
Next Generation of the UCLA Abutment
      Safety of Shape Memory Alloy, “Nitinol”
               (Nickel titanium alloy)
 ‣  Nitinol is safe and bio-compatible	

 ‣  Many devices are approved by FDA	

 ‣  Economical to manufacture	

                     Heart balloon

  Arch bars
                              Heart stent
Release of the crown	

 Shape memory device is activated by heat	





Activation brings the temperature up to 55
degrees Centigrade. It’s a shape change
Next Generation of the UCLA Abutment
  Measurement of Temperature Rise in Abutment and
       Implant Fixture During Heat Activation
Next Generation of the UCLA Abutment
 Measurement of Temperature Rise in Abutment
   and Implant Fixture During Heat Activation
                           ΔT, implant fixture (°C)
   ΔT, abutment (°C)

       Passive air cool
             1.4
                    2.8

       Forced air cool
              0.3
                    2.1
Next Generation of the UCLA Abutment
      Measurement of Retention Strength



          Temperature
            Chamber
Next Generation of the UCLA Abutment
                Measurement of Retention Strength	

                           - Set up -	

     Assembly: implant
Saline chamber: body temperature
               fixture + abutment +
                                                    RODO sleeve
Measurement of Retention Strength	

            Results 	

                                      Min - Max. (N)

            Provisional cement
            30 - 250

              Zinc phosphate
           330 - 346

              RODO Device!             275 - 1,500!




      Shape memory sleeve after the test
Measurement of Maximum Compressive
               Strength
ISO 14801 Guideline
     - Set up -
                       Assembly: implant fixture +     Saline Chamber
                        abutment + RODO sleeve
     (Body Temperature)
Measurement of Maximum
                        Compressive Strength 	

                                Results    	

                                                     Maximum Abutment Strength
  Failed at abutment-                               *No failure in the RODO Device
implant fixture interface



                                                                     750 N




                                           Failure of Conventional Abutments : 800 ~ 1,000 N


                                 Screw fractured
Next Generation of the UCLA Abutment
                    ISO 14801:2007-11-15
           Dynamic Fatigue Test for Endosseous Dental
                            Implants
  Failed at abutment-              Displacement controlled fatigue performance
implant fixture interface
                 *No failure in the RODO Device




                                   50 - 400
  Screw failed at 6000 cycles          Minimum # of cycles
Next Generation of the UCLA Abutment
                  (Seo ,Wu and Shah)
                Upcoming Studies
v    Galvanic testing
v    Short term IRB trial at UCLA School of Dentistry
      (Kumar Shah and Neil Garrett)
v    Long term IRB trials at UCLA, other universities
      and private clinics in the US commenced
      summer 2011.
Patients with known nickel allergies not candidates
Platform Reduction and Etiology of Marginal
           Bone Loss around Implants
  Original Branemark design lost bone down to the first
  thread. Why?

v  Thread  design?
v  Surface topography?
v  Conical implant seal?
v  Design of the neck?
v  Platform reduction?
    (switching)
Etiology of the initial bone loss
       around implants
v  Almost   immediately the
    original “Branemark”
    design lost bone down to
    the first thread.
v  Other designs such as the
    “Astra” design appear to
    retain their bone levels
v  What is the evidence?

What are the likely explanations
for this difference?
Etiology of initial bone loss around implants
 Angulation of the neck
    v An  implant is torqued into position with 45 Newtons
    v However, the torque values around the neck of the
       implant imbedded in the cortical bone is probably
       closer to 100 Newtons.
    v Will these values predispose to resorption to the
       cortical bone around the neck of the implant when the
       angle of the implant is acute?
Etiology of initial bone loss around implants
 v Angulation   of the neck
    v Whenocclusal loads are applied will the implants
     with acute angles atop of the implant overload
     the bone in this area precipitating a resorptive
     remodeling response and bone loss?
Platform reduction (platform switching)
         Courtesy G. Perri   Courtesy C. Stanford




v Note the bone levels atop the implant.
v Is it the result of the horizontalization of     the
     biologic width (platform reduction)?
Platform reduction (platform switching)
          Courtesy G. Perri   Courtesy C. Stanford




The evidence is far from clear.
  v In these examples the angulation of the top of the
       implant may be the more important factor
  v In addition in both these implant systems the micro-rough
       surface was extended to the top of the implant. This also,
       may contribute to the maintenance of bone levels atop
       the implant.
Angulation of the neck




v  Some    authors have maintained that the angulation
    atop the implant is the most important factor.
    (Braun, et al, 2006; Iacono et al , 2006)
v  They attribute the maintenance of bone atop of the
    implant to the so-called “negative” slope (dotted
    lines).
The presence of micro-threads
Courtesy G. Perri    Courtesy C. Stanford




       Is it the result of the microthreads
       around the neck of the implant?
Internal interlocking vs external hex
                   system
                      Conical seal
v  Allabutment – implant fixture interfaces demonstrate gaps
    upon loading from 10-50 microns. The original external hex
    systems demonstrates the largest gaps during flexure.
v  Do these gaps harbor micro-organism which in turn precipitate
    an inflammatory response leading to bone loss around the
    neck of the implant?
Marginal Bone Loss
Based on a Med Line search, a review of the literature
indicated that no implant system, surface or design
was found superior with regards to marginal bone loss
(Abrahamsson and Berhlundh, 2009)
Platform Switching (Reduction)
Will this type of implant fixture – abutment
configuration minimize the bone loss around the neck
of implants?




v Basedon a review by Bateli and Strub (2011) “the current literature
provides insufficient evidence about the effectiveness of any specific
modification in the implant neck area in preserving marginal bone or
preventing marginal bone loss”
One piece systems
Nobel direct and similar one piece systems
    There are no gaps developing between an
    abutment and fixture. Why the bone loss?
    Most have modern surfaces.


    Many were immediately provisionalized and
    loaded with cement retained restorations. In
    many cases the cement extended down to
    the boney levels
    v Aninflammatory response was initiated which was
      progressive and irreversible leading to extensive
      bone loss.
Zirconium Implant Fixtures
                                       (Strub et al, 2010)

 v    Has been promoted for use in the esthetic zone
 v    Biocompatible
       "   Histology similar to titanium – about 60% bone implant contact area
       "   Anchorage is similar to titanium
 v    Microrough surfaces the best
 v    Success rates equivalent to titanium
 v    UV exposure makes the surface more bioreactive
 v  Fractures
      " One piece system – fractures at ¼ the load compared to titanium
      " Two piece systems fracture at 1/6th the load compared to titanium
      " Alumina reinforced zirconium is stronger



Not ready for clinical use. Some people believe that zirconium
implants will eventually disappear from the market.
Zirconium abutments and frameworks
Used in the esthetic zone
  Abutments
  l    Less plague adherence
  l    More esthetic
  l    Higher fracture rate
  Frameworks
         l    High incidence of chipping of porcelain
               off the zirconium frameworks
         l    Not recommended for posterior teeth




                                                         Courtesy Dr. A. Sharma
v  Visitffofr.org for hundreds of additional lectures
    on Complete Dentures, Implant Dentistry,
    Removable Partial Dentures, Esthetic Dentistry
    and Maxillofacial Prosthetics.
v  The lectures are free.
v  Our objective is to create the best and most
    comprehensive online programs of instruction in
    Prosthodontics

Weitere ähnliche Inhalte

Was ist angesagt?

Full mouth dawson
Full mouth  dawsonFull mouth  dawson
Full mouth dawsonAnish Amin
 
Surgical implant placement guides/ dentistry dental implants
Surgical implant placement guides/ dentistry dental implantsSurgical implant placement guides/ dentistry dental implants
Surgical implant placement guides/ dentistry dental implantsIndian dental academy
 
Full mouth rehabilitation using pankey mann schulyer technique
Full mouth rehabilitation using pankey mann schulyer techniqueFull mouth rehabilitation using pankey mann schulyer technique
Full mouth rehabilitation using pankey mann schulyer techniqueFebel Huda
 
Classification and impression techniques of implants/ dentistry dental implants
Classification and impression techniques of implants/ dentistry dental implantsClassification and impression techniques of implants/ dentistry dental implants
Classification and impression techniques of implants/ dentistry dental implantsIndian dental academy
 
All on 4 and all on 6
All on 4 and all on 6All on 4 and all on 6
All on 4 and all on 6DR PAAVANA
 
Journal Club Presentation on Overlay Removable Partial Denture
Journal  Club Presentation on Overlay Removable Partial DentureJournal  Club Presentation on Overlay Removable Partial Denture
Journal Club Presentation on Overlay Removable Partial DentureNeerajaMenon4
 
Implant prosthetic considerations
Implant   prosthetic considerationsImplant   prosthetic considerations
Implant prosthetic considerationsNitika Jain
 
Loading of dental implants / general dental courses
Loading of dental implants / general dental courses Loading of dental implants / general dental courses
Loading of dental implants / general dental courses Indian dental academy
 
Cement Retained Versus Screw Retained Implant Restorations Achieving Optimal
Cement Retained Versus Screw Retained Implant Restorations Achieving OptimalCement Retained Versus Screw Retained Implant Restorations Achieving Optimal
Cement Retained Versus Screw Retained Implant Restorations Achieving OptimalMohammed Alshehri
 
Osseodensification
Osseodensification Osseodensification
Osseodensification Naveed AnJum
 
Occlusion in implant ss
Occlusion in implant ssOcclusion in implant ss
Occlusion in implant ssMurtaza Kaderi
 
Implant supported overdenture
Implant supported overdenture Implant supported overdenture
Implant supported overdenture Anuja Gunjal
 
Classification and impression techniques of implants/prosthodontic courses
Classification and impression techniques of implants/prosthodontic coursesClassification and impression techniques of implants/prosthodontic courses
Classification and impression techniques of implants/prosthodontic coursesIndian dental academy
 
Diagnosis and treatment planning in implant dentistry
Diagnosis and treatment planning in implant dentistryDiagnosis and treatment planning in implant dentistry
Diagnosis and treatment planning in implant dentistryLaju Mahesh
 
Koshy's full mouth presentation
Koshy's full mouth presentationKoshy's full mouth presentation
Koshy's full mouth presentationJoel Koshy
 
IMPLANT OCCLUSION
IMPLANT OCCLUSIONIMPLANT OCCLUSION
IMPLANT OCCLUSIONshari kurup
 
Different implant abutment connections
Different implant abutment connectionsDifferent implant abutment connections
Different implant abutment connectionsMohammad Algraisi
 
Precision attachments
Precision attachmentsPrecision attachments
Precision attachmentsJoel Koshy
 

Was ist angesagt? (20)

Full mouth dawson
Full mouth  dawsonFull mouth  dawson
Full mouth dawson
 
Surgical implant placement guides/ dentistry dental implants
Surgical implant placement guides/ dentistry dental implantsSurgical implant placement guides/ dentistry dental implants
Surgical implant placement guides/ dentistry dental implants
 
Full mouth rehabilitation using pankey mann schulyer technique
Full mouth rehabilitation using pankey mann schulyer techniqueFull mouth rehabilitation using pankey mann schulyer technique
Full mouth rehabilitation using pankey mann schulyer technique
 
Overdentures
OverdenturesOverdentures
Overdentures
 
Classification and impression techniques of implants/ dentistry dental implants
Classification and impression techniques of implants/ dentistry dental implantsClassification and impression techniques of implants/ dentistry dental implants
Classification and impression techniques of implants/ dentistry dental implants
 
OSSEODENSIFICATION
OSSEODENSIFICATIONOSSEODENSIFICATION
OSSEODENSIFICATION
 
All on 4 and all on 6
All on 4 and all on 6All on 4 and all on 6
All on 4 and all on 6
 
Journal Club Presentation on Overlay Removable Partial Denture
Journal  Club Presentation on Overlay Removable Partial DentureJournal  Club Presentation on Overlay Removable Partial Denture
Journal Club Presentation on Overlay Removable Partial Denture
 
Implant prosthetic considerations
Implant   prosthetic considerationsImplant   prosthetic considerations
Implant prosthetic considerations
 
Loading of dental implants / general dental courses
Loading of dental implants / general dental courses Loading of dental implants / general dental courses
Loading of dental implants / general dental courses
 
Cement Retained Versus Screw Retained Implant Restorations Achieving Optimal
Cement Retained Versus Screw Retained Implant Restorations Achieving OptimalCement Retained Versus Screw Retained Implant Restorations Achieving Optimal
Cement Retained Versus Screw Retained Implant Restorations Achieving Optimal
 
Osseodensification
Osseodensification Osseodensification
Osseodensification
 
Occlusion in implant ss
Occlusion in implant ssOcclusion in implant ss
Occlusion in implant ss
 
Implant supported overdenture
Implant supported overdenture Implant supported overdenture
Implant supported overdenture
 
Classification and impression techniques of implants/prosthodontic courses
Classification and impression techniques of implants/prosthodontic coursesClassification and impression techniques of implants/prosthodontic courses
Classification and impression techniques of implants/prosthodontic courses
 
Diagnosis and treatment planning in implant dentistry
Diagnosis and treatment planning in implant dentistryDiagnosis and treatment planning in implant dentistry
Diagnosis and treatment planning in implant dentistry
 
Koshy's full mouth presentation
Koshy's full mouth presentationKoshy's full mouth presentation
Koshy's full mouth presentation
 
IMPLANT OCCLUSION
IMPLANT OCCLUSIONIMPLANT OCCLUSION
IMPLANT OCCLUSION
 
Different implant abutment connections
Different implant abutment connectionsDifferent implant abutment connections
Different implant abutment connections
 
Precision attachments
Precision attachmentsPrecision attachments
Precision attachments
 

Ähnlich wie Abutment Selection

Alignment of blocked out maxillary lateral incisors-jcojuly2000
Alignment of blocked out maxillary lateral incisors-jcojuly2000Alignment of blocked out maxillary lateral incisors-jcojuly2000
Alignment of blocked out maxillary lateral incisors-jcojuly2000Indian dental academy
 
Auxillary methods of retention in class ii dental amalgam restorations
Auxillary methods of retention in class ii dental amalgam restorationsAuxillary methods of retention in class ii dental amalgam restorations
Auxillary methods of retention in class ii dental amalgam restorationsIndian dental academy
 
Sem crown removars/cosmetic dentistry courses
Sem crown removars/cosmetic dentistry coursesSem crown removars/cosmetic dentistry courses
Sem crown removars/cosmetic dentistry coursesIndian dental academy
 
inlays and onlays, classification of inlays and onlays
inlays and onlays, classification of inlays and onlaysinlays and onlays, classification of inlays and onlays
inlays and onlays, classification of inlays and onlaysaishwaryakhare5
 
Screw retained vs cement retained prosthesis.pptx
Screw retained vs cement retained prosthesis.pptxScrew retained vs cement retained prosthesis.pptx
Screw retained vs cement retained prosthesis.pptxRanjanaRavindran1
 
Screw retained vs cement retained prosthesis.pptx
Screw retained vs cement retained prosthesis.pptxScrew retained vs cement retained prosthesis.pptx
Screw retained vs cement retained prosthesis.pptxRanjanaRavindran1
 
Basal Implant rehabilitation in oral surgery
Basal Implant rehabilitation in oral  surgeryBasal Implant rehabilitation in oral  surgery
Basal Implant rehabilitation in oral surgerysuhaskamble151
 

Ähnlich wie Abutment Selection (20)

Biomechanics and Treatment Planning
Biomechanics and Treatment PlanningBiomechanics and Treatment Planning
Biomechanics and Treatment Planning
 
Alignment of blocked out maxillary lateral incisors-jcojuly2000
Alignment of blocked out maxillary lateral incisors-jcojuly2000Alignment of blocked out maxillary lateral incisors-jcojuly2000
Alignment of blocked out maxillary lateral incisors-jcojuly2000
 
Restoration of ear defects
Restoration of ear defectsRestoration of ear defects
Restoration of ear defects
 
Prosthodontics Procedures and Complications - Posterior Quadrants
 Prosthodontics Procedures and Complications - Posterior Quadrants Prosthodontics Procedures and Complications - Posterior Quadrants
Prosthodontics Procedures and Complications - Posterior Quadrants
 
13.overlay rpd’s
13.overlay rpd’s13.overlay rpd’s
13.overlay rpd’s
 
32(new).preprosthetic surgical procedures (n)
32(new).preprosthetic surgical procedures (n)32(new).preprosthetic surgical procedures (n)
32(new).preprosthetic surgical procedures (n)
 
Auxillary methods of retention in class ii dental amalgam restorations
Auxillary methods of retention in class ii dental amalgam restorationsAuxillary methods of retention in class ii dental amalgam restorations
Auxillary methods of retention in class ii dental amalgam restorations
 
inlays and onlays.ppt
inlays and onlays.pptinlays and onlays.ppt
inlays and onlays.ppt
 
Retainers in fpd/dental courses
Retainers in fpd/dental coursesRetainers in fpd/dental courses
Retainers in fpd/dental courses
 
13.edent max overlay dentures
13.edent max overlay dentures13.edent max overlay dentures
13.edent max overlay dentures
 
PONTICS..pptx
PONTICS..pptxPONTICS..pptx
PONTICS..pptx
 
Sem crown removars/cosmetic dentistry courses
Sem crown removars/cosmetic dentistry coursesSem crown removars/cosmetic dentistry courses
Sem crown removars/cosmetic dentistry courses
 
24.(new)mfp defects and rpd design
24.(new)mfp defects and rpd design24.(new)mfp defects and rpd design
24.(new)mfp defects and rpd design
 
16. (new)maxillary obturators trouble shooting, relines and other issues
16. (new)maxillary obturators trouble shooting, relines and other issues16. (new)maxillary obturators trouble shooting, relines and other issues
16. (new)maxillary obturators trouble shooting, relines and other issues
 
inlays and onlays, classification of inlays and onlays
inlays and onlays, classification of inlays and onlaysinlays and onlays, classification of inlays and onlays
inlays and onlays, classification of inlays and onlays
 
Screw retained vs cement retained prosthesis.pptx
Screw retained vs cement retained prosthesis.pptxScrew retained vs cement retained prosthesis.pptx
Screw retained vs cement retained prosthesis.pptx
 
Screw retained vs cement retained prosthesis.pptx
Screw retained vs cement retained prosthesis.pptxScrew retained vs cement retained prosthesis.pptx
Screw retained vs cement retained prosthesis.pptx
 
Restoration of orbital defects
Restoration of orbital defectsRestoration of orbital defects
Restoration of orbital defects
 
Basal Implant rehabilitation in oral surgery
Basal Implant rehabilitation in oral  surgeryBasal Implant rehabilitation in oral  surgery
Basal Implant rehabilitation in oral surgery
 
Edentulous Maxilla - Fixed Prostheses
Edentulous Maxilla - Fixed ProsthesesEdentulous Maxilla - Fixed Prostheses
Edentulous Maxilla - Fixed Prostheses
 

Mehr von www.ffofr.org - Foundation for Oral Facial Rehabilitiation

Mehr von www.ffofr.org - Foundation for Oral Facial Rehabilitiation (20)

Digital Design of Mandibular Removable Partial Dentures
Digital Design of Mandibular Removable Partial DenturesDigital Design of Mandibular Removable Partial Dentures
Digital Design of Mandibular Removable Partial Dentures
 
Digital design of maxillary of rpd's
Digital design of maxillary of rpd'sDigital design of maxillary of rpd's
Digital design of maxillary of rpd's
 
Single tooth
Single toothSingle tooth
Single tooth
 
Restoration of posterior quadrants
Restoration of posterior quadrantsRestoration of posterior quadrants
Restoration of posterior quadrants
 
Implants and rp ds
Implants and rp dsImplants and rp ds
Implants and rp ds
 
Computer guided
Computer guidedComputer guided
Computer guided
 
Angled implants
Angled implantsAngled implants
Angled implants
 
Restoration of endodontically treated teeth
Restoration of endodontically treated teethRestoration of endodontically treated teeth
Restoration of endodontically treated teeth
 
Provisional restorations
Provisional restorationsProvisional restorations
Provisional restorations
 
Secondard impression materials
Secondard impression materialsSecondard impression materials
Secondard impression materials
 
Fluid control and tissue managemtent
Fluid control and tissue managemtentFluid control and tissue managemtent
Fluid control and tissue managemtent
 
Ceramics in fixed prosthodontics considerations for use in dental practice
Ceramics in fixed prosthodontics   considerations for use in dental practiceCeramics in fixed prosthodontics   considerations for use in dental practice
Ceramics in fixed prosthodontics considerations for use in dental practice
 
Dental cements and cementation procedures
Dental cements and cementation proceduresDental cements and cementation procedures
Dental cements and cementation procedures
 
Single tooth defects in the posterior quadrants
Single tooth defects in the posterior quadrantsSingle tooth defects in the posterior quadrants
Single tooth defects in the posterior quadrants
 
12.resin bonded prostheses
12.resin bonded prostheses12.resin bonded prostheses
12.resin bonded prostheses
 
11.tp & fpd designs
11.tp & fpd designs11.tp & fpd designs
11.tp & fpd designs
 
10.rest rct
10.rest rct10.rest rct
10.rest rct
 
9.dental cements
9.dental cements9.dental cements
9.dental cements
 
8.prov rest
8.prov rest8.prov rest
8.prov rest
 
7.contour fitsmoothness
7.contour fitsmoothness7.contour fitsmoothness
7.contour fitsmoothness
 

Kürzlich hochgeladen

Call Girls Aurangabad Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Aurangabad Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Aurangabad Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Aurangabad Just Call 9907093804 Top Class Call Girl Service AvailableDipal Arora
 
Call Girls Bhubaneswar Just Call 9907093804 Top Class Call Girl Service Avail...
Call Girls Bhubaneswar Just Call 9907093804 Top Class Call Girl Service Avail...Call Girls Bhubaneswar Just Call 9907093804 Top Class Call Girl Service Avail...
Call Girls Bhubaneswar Just Call 9907093804 Top Class Call Girl Service Avail...Dipal Arora
 
VIP Mumbai Call Girls Hiranandani Gardens Just Call 9920874524 with A/C Room ...
VIP Mumbai Call Girls Hiranandani Gardens Just Call 9920874524 with A/C Room ...VIP Mumbai Call Girls Hiranandani Gardens Just Call 9920874524 with A/C Room ...
VIP Mumbai Call Girls Hiranandani Gardens Just Call 9920874524 with A/C Room ...Garima Khatri
 
Call Girls Varanasi Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Varanasi Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Varanasi Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Varanasi Just Call 9907093804 Top Class Call Girl Service AvailableDipal Arora
 
♛VVIP Hyderabad Call Girls Chintalkunta🖕7001035870🖕Riya Kappor Top Call Girl ...
♛VVIP Hyderabad Call Girls Chintalkunta🖕7001035870🖕Riya Kappor Top Call Girl ...♛VVIP Hyderabad Call Girls Chintalkunta🖕7001035870🖕Riya Kappor Top Call Girl ...
♛VVIP Hyderabad Call Girls Chintalkunta🖕7001035870🖕Riya Kappor Top Call Girl ...astropune
 
Kesar Bagh Call Girl Price 9548273370 , Lucknow Call Girls Service
Kesar Bagh Call Girl Price 9548273370 , Lucknow Call Girls ServiceKesar Bagh Call Girl Price 9548273370 , Lucknow Call Girls Service
Kesar Bagh Call Girl Price 9548273370 , Lucknow Call Girls Servicemakika9823
 
Call Girls Nagpur Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Nagpur Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Nagpur Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Nagpur Just Call 9907093804 Top Class Call Girl Service AvailableDipal Arora
 
Premium Call Girls Cottonpet Whatsapp 7001035870 Independent Escort Service
Premium Call Girls Cottonpet Whatsapp 7001035870 Independent Escort ServicePremium Call Girls Cottonpet Whatsapp 7001035870 Independent Escort Service
Premium Call Girls Cottonpet Whatsapp 7001035870 Independent Escort Servicevidya singh
 
Call Girls Coimbatore Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Coimbatore Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Coimbatore Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Coimbatore Just Call 9907093804 Top Class Call Girl Service AvailableDipal Arora
 
Low Rate Call Girls Kochi Anika 8250192130 Independent Escort Service Kochi
Low Rate Call Girls Kochi Anika 8250192130 Independent Escort Service KochiLow Rate Call Girls Kochi Anika 8250192130 Independent Escort Service Kochi
Low Rate Call Girls Kochi Anika 8250192130 Independent Escort Service KochiSuhani Kapoor
 
The Most Attractive Hyderabad Call Girls Kothapet 𖠋 6297143586 𖠋 Will You Mis...
The Most Attractive Hyderabad Call Girls Kothapet 𖠋 6297143586 𖠋 Will You Mis...The Most Attractive Hyderabad Call Girls Kothapet 𖠋 6297143586 𖠋 Will You Mis...
The Most Attractive Hyderabad Call Girls Kothapet 𖠋 6297143586 𖠋 Will You Mis...chandars293
 
Chandrapur Call girls 8617370543 Provides all area service COD available
Chandrapur Call girls 8617370543 Provides all area service COD availableChandrapur Call girls 8617370543 Provides all area service COD available
Chandrapur Call girls 8617370543 Provides all area service COD availableDipal Arora
 
Call Girls Kochi Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Kochi Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Kochi Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Kochi Just Call 9907093804 Top Class Call Girl Service AvailableDipal Arora
 
(Rocky) Jaipur Call Girl - 9521753030 Escorts Service 50% Off with Cash ON De...
(Rocky) Jaipur Call Girl - 9521753030 Escorts Service 50% Off with Cash ON De...(Rocky) Jaipur Call Girl - 9521753030 Escorts Service 50% Off with Cash ON De...
(Rocky) Jaipur Call Girl - 9521753030 Escorts Service 50% Off with Cash ON De...indiancallgirl4rent
 
Top Rated Bangalore Call Girls Mg Road ⟟ 8250192130 ⟟ Call Me For Genuine Sex...
Top Rated Bangalore Call Girls Mg Road ⟟ 8250192130 ⟟ Call Me For Genuine Sex...Top Rated Bangalore Call Girls Mg Road ⟟ 8250192130 ⟟ Call Me For Genuine Sex...
Top Rated Bangalore Call Girls Mg Road ⟟ 8250192130 ⟟ Call Me For Genuine Sex...narwatsonia7
 
Night 7k to 12k Chennai City Center Call Girls 👉👉 7427069034⭐⭐ 100% Genuine E...
Night 7k to 12k Chennai City Center Call Girls 👉👉 7427069034⭐⭐ 100% Genuine E...Night 7k to 12k Chennai City Center Call Girls 👉👉 7427069034⭐⭐ 100% Genuine E...
Night 7k to 12k Chennai City Center Call Girls 👉👉 7427069034⭐⭐ 100% Genuine E...hotbabesbook
 
Call Girls Siliguri Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Siliguri Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Siliguri Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Siliguri Just Call 9907093804 Top Class Call Girl Service AvailableDipal Arora
 
Call Girls Horamavu WhatsApp Number 7001035870 Meeting With Bangalore Escorts
Call Girls Horamavu WhatsApp Number 7001035870 Meeting With Bangalore EscortsCall Girls Horamavu WhatsApp Number 7001035870 Meeting With Bangalore Escorts
Call Girls Horamavu WhatsApp Number 7001035870 Meeting With Bangalore Escortsvidya singh
 
Call Girls Service Jaipur Grishma WhatsApp ❤8445551418 VIP Call Girls Jaipur
Call Girls Service Jaipur Grishma WhatsApp ❤8445551418 VIP Call Girls JaipurCall Girls Service Jaipur Grishma WhatsApp ❤8445551418 VIP Call Girls Jaipur
Call Girls Service Jaipur Grishma WhatsApp ❤8445551418 VIP Call Girls Jaipurparulsinha
 

Kürzlich hochgeladen (20)

Call Girls Aurangabad Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Aurangabad Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Aurangabad Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Aurangabad Just Call 9907093804 Top Class Call Girl Service Available
 
Call Girls Bhubaneswar Just Call 9907093804 Top Class Call Girl Service Avail...
Call Girls Bhubaneswar Just Call 9907093804 Top Class Call Girl Service Avail...Call Girls Bhubaneswar Just Call 9907093804 Top Class Call Girl Service Avail...
Call Girls Bhubaneswar Just Call 9907093804 Top Class Call Girl Service Avail...
 
VIP Mumbai Call Girls Hiranandani Gardens Just Call 9920874524 with A/C Room ...
VIP Mumbai Call Girls Hiranandani Gardens Just Call 9920874524 with A/C Room ...VIP Mumbai Call Girls Hiranandani Gardens Just Call 9920874524 with A/C Room ...
VIP Mumbai Call Girls Hiranandani Gardens Just Call 9920874524 with A/C Room ...
 
Call Girls Varanasi Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Varanasi Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Varanasi Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Varanasi Just Call 9907093804 Top Class Call Girl Service Available
 
♛VVIP Hyderabad Call Girls Chintalkunta🖕7001035870🖕Riya Kappor Top Call Girl ...
♛VVIP Hyderabad Call Girls Chintalkunta🖕7001035870🖕Riya Kappor Top Call Girl ...♛VVIP Hyderabad Call Girls Chintalkunta🖕7001035870🖕Riya Kappor Top Call Girl ...
♛VVIP Hyderabad Call Girls Chintalkunta🖕7001035870🖕Riya Kappor Top Call Girl ...
 
Kesar Bagh Call Girl Price 9548273370 , Lucknow Call Girls Service
Kesar Bagh Call Girl Price 9548273370 , Lucknow Call Girls ServiceKesar Bagh Call Girl Price 9548273370 , Lucknow Call Girls Service
Kesar Bagh Call Girl Price 9548273370 , Lucknow Call Girls Service
 
Call Girls Nagpur Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Nagpur Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Nagpur Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Nagpur Just Call 9907093804 Top Class Call Girl Service Available
 
Premium Call Girls Cottonpet Whatsapp 7001035870 Independent Escort Service
Premium Call Girls Cottonpet Whatsapp 7001035870 Independent Escort ServicePremium Call Girls Cottonpet Whatsapp 7001035870 Independent Escort Service
Premium Call Girls Cottonpet Whatsapp 7001035870 Independent Escort Service
 
Call Girls Coimbatore Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Coimbatore Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Coimbatore Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Coimbatore Just Call 9907093804 Top Class Call Girl Service Available
 
Low Rate Call Girls Kochi Anika 8250192130 Independent Escort Service Kochi
Low Rate Call Girls Kochi Anika 8250192130 Independent Escort Service KochiLow Rate Call Girls Kochi Anika 8250192130 Independent Escort Service Kochi
Low Rate Call Girls Kochi Anika 8250192130 Independent Escort Service Kochi
 
The Most Attractive Hyderabad Call Girls Kothapet 𖠋 6297143586 𖠋 Will You Mis...
The Most Attractive Hyderabad Call Girls Kothapet 𖠋 6297143586 𖠋 Will You Mis...The Most Attractive Hyderabad Call Girls Kothapet 𖠋 6297143586 𖠋 Will You Mis...
The Most Attractive Hyderabad Call Girls Kothapet 𖠋 6297143586 𖠋 Will You Mis...
 
Chandrapur Call girls 8617370543 Provides all area service COD available
Chandrapur Call girls 8617370543 Provides all area service COD availableChandrapur Call girls 8617370543 Provides all area service COD available
Chandrapur Call girls 8617370543 Provides all area service COD available
 
Call Girls Kochi Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Kochi Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Kochi Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Kochi Just Call 9907093804 Top Class Call Girl Service Available
 
(Rocky) Jaipur Call Girl - 9521753030 Escorts Service 50% Off with Cash ON De...
(Rocky) Jaipur Call Girl - 9521753030 Escorts Service 50% Off with Cash ON De...(Rocky) Jaipur Call Girl - 9521753030 Escorts Service 50% Off with Cash ON De...
(Rocky) Jaipur Call Girl - 9521753030 Escorts Service 50% Off with Cash ON De...
 
Top Rated Bangalore Call Girls Mg Road ⟟ 8250192130 ⟟ Call Me For Genuine Sex...
Top Rated Bangalore Call Girls Mg Road ⟟ 8250192130 ⟟ Call Me For Genuine Sex...Top Rated Bangalore Call Girls Mg Road ⟟ 8250192130 ⟟ Call Me For Genuine Sex...
Top Rated Bangalore Call Girls Mg Road ⟟ 8250192130 ⟟ Call Me For Genuine Sex...
 
Night 7k to 12k Chennai City Center Call Girls 👉👉 7427069034⭐⭐ 100% Genuine E...
Night 7k to 12k Chennai City Center Call Girls 👉👉 7427069034⭐⭐ 100% Genuine E...Night 7k to 12k Chennai City Center Call Girls 👉👉 7427069034⭐⭐ 100% Genuine E...
Night 7k to 12k Chennai City Center Call Girls 👉👉 7427069034⭐⭐ 100% Genuine E...
 
Escort Service Call Girls In Sarita Vihar,, 99530°56974 Delhi NCR
Escort Service Call Girls In Sarita Vihar,, 99530°56974 Delhi NCREscort Service Call Girls In Sarita Vihar,, 99530°56974 Delhi NCR
Escort Service Call Girls In Sarita Vihar,, 99530°56974 Delhi NCR
 
Call Girls Siliguri Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Siliguri Just Call 9907093804 Top Class Call Girl Service AvailableCall Girls Siliguri Just Call 9907093804 Top Class Call Girl Service Available
Call Girls Siliguri Just Call 9907093804 Top Class Call Girl Service Available
 
Call Girls Horamavu WhatsApp Number 7001035870 Meeting With Bangalore Escorts
Call Girls Horamavu WhatsApp Number 7001035870 Meeting With Bangalore EscortsCall Girls Horamavu WhatsApp Number 7001035870 Meeting With Bangalore Escorts
Call Girls Horamavu WhatsApp Number 7001035870 Meeting With Bangalore Escorts
 
Call Girls Service Jaipur Grishma WhatsApp ❤8445551418 VIP Call Girls Jaipur
Call Girls Service Jaipur Grishma WhatsApp ❤8445551418 VIP Call Girls JaipurCall Girls Service Jaipur Grishma WhatsApp ❤8445551418 VIP Call Girls Jaipur
Call Girls Service Jaipur Grishma WhatsApp ❤8445551418 VIP Call Girls Jaipur
 

Abutment Selection

  • 1. 9. Abutment selection John Beumer III DDS, MS George Perri DDS Division of Advanced Prosthodontics, Biomaterials and Hospital Dentistry, UCLA This program of instruction is protected by copyright ©. No portion of this program of instruction may be reproduced, recorded or transferred by any means electronic, digital, photographic, mechanical etc., or by any information storage or retrieval system, without prior permission.
  • 2. Restoration connection to abutment and/or implant fixture Biologic and technical issues v  Screw retained systems v  Cement retained systems v  Screwless - cementless system (UCLA II) v  Platform reduction (ie platform switching)
  • 3. Arguments commonly used in favor of cementation v  It’s a common procedure in the dental office: No “Implant” knowledge necessary? v  Implants for dummies v  The screw access hole is through the labial or buccal v  Other options - Lingual set screws-lab expense and lab expertise v  Simple traditional impression techniques? v  Packing gingival retraction cord vs screw retained impression copings v  Better esthetics? v  Permits the use of zirconium abutments. Predictability of Zirconium abutments? v  Fit isn’t as critical v  Really? The assumption is that a misfit is just a passive cement gap with no negative consequences
  • 5. Subgingival cement accumulation Prepable abutment These abutments can be prepared at the lab bench or intraorally. An impression is made and the restoration is cemented in the usual and customary fashion.
  • 6. Subgingival cement accumulation Prepable abutment An impression was obtained with an impression coping and the prepable abutment was attached to the fixture analogue imbedded in the master cast.
  • 7. Subgingival cement accumulation Prepable abutment v The abutment is prepared so that the margin is slightly sub gingival. v An impression is made and the porcelain fused to metal crown was completed in a customary fashion. v The abutment is secured to the implant fixture and the crown is then cemented.
  • 8. Subgingival cement accumulation Prepable abutment v The patient was unhappy with the esthetic result and so a hole was drilled into the occlusal surface in order to access the abutment screw. The crown and abutment was then removed v Note the accumulation of cement subgingivally.
  • 9. Subgingival cement accumulation Sulcus Epithelium Implant Surface Why is there a greater risk of cement accumulation in the sulcus of implant crowns? Peri-implant tissues are more easily displaced from Circumferential the surface of collagen fibers the restoration. Bone *
  • 10. Anatomy & Biology of Peri-Implant Soft Tissue Similarities between periodontal & peri-implant soft tissues: v  Oral epithelium v  Sulcular epithelium v  Junctional epithelium Differences in peri-implant soft tissues include: v  Lack of CT attachment v  Hypovascular, hypocellular CT zone adjacent to the implant v  Absence of periodontal ligament blood supply Sclar AG, 2003
  • 11. Cementation permits use of a ceramic abutment Excellent esthetic result v  Subgingival cement accumulation can be limited by packing gingival retraction cord prior to cementation v  Allows the creation of an all ceramic restoration from the implant to the incisal edge. Is there an esthetic advantage? Perhaps. v  The main issue is positioning of the cement margin v  Incidence of fracture of zirconium abutments is a concern but long term followup data is not yet available.
  • 12. Preformed nonprepable abutments Issues of concern v  Positionof the cement margin in relation to the gingival margin v Particularly significant in the anterior region v  Impaction of cement into the gingival sulcus v  Difficulty in seating the crown because of hydraulic pressure
  • 13. Preformed nonprepable abutments Considerations for use: v Tissue height essentially the same 360 degrees around the abutment v Head of the implant or abutment cement margin just subgingival v Sufficient clearance for sufficient axial wall height for predictable cement retention v Angulation allows reasonable draw with adjacent teeth
  • 14. Preformed nonprepable abutments v  The margin between the crown and the abutment does not follow the gingival margin. v  There is significant risk of trapping cement beneath the gingival tissues upon cementation.
  • 15. Preformed nonprepable abutments This patient presented with severe peri-implantitis 3 years post insertion of the crown. The initial x-ray A subsequent appeared to x-ray, taken at indicate that the right angles to crown was the long axis of seated. the implant, revealed that the crown, was not seated. Inability to completely seat the crown onto the abutment is a common complication associated with preformed abutments. Lingual access holes may help relieve the hydraulic pressure and enable seating of the crown.
  • 16. Preformed nonprepable abutments Note the inflammation associated with the peri- implant gingiva 2 1/2 years post insertion.
  • 17. UCLA Abutment Indications: a)  Lack of interocclusal space b)  Restorations in the esthetic zone c)  Angulation problems d)  Soft tissue problems
  • 20. Custom abutments with screw retained restorations Advantages v  Control thickness of labial porcelain v  Used when the Waxing implant is inclined sleeve excessively to the labial. v  Retrievable Full contour wax pattern is developed
  • 21. Custom abutments with screw retained restorations Wax cut back Sprued wax pattern Lingual retention screw channel
  • 22. Custom abutments with screw retained restorations Cast custom abutment Note lingual retention screw orifice
  • 23. Custom abutments with screw retained restorations Coping Completed and sprued wax pattern Lingual retention screw channel Labial index fabricated following the full contour wax pattern.
  • 24. Custom abutments with screw retained restorations Completed crown Retention screw Abutment screw Custom abutment
  • 25. Custom abutments with screw retained restorations Completed restoration Lingual retention screw
  • 26. Custom abutments with screw retained restorations
  • 27. Custom abutments with screw retained restorations Healing Full contour abutment wax pattern Completed Wax pattern of custom abutment custom abutment
  • 28. Custom abutments with screw retained restorations Completed restoration. Note the level of the gingiva
  • 29. Custom abutments with screw retained restorations Gingival levels do not match but the the patient does not display his gingiva during a high smile.
  • 30. Custom abutments allows the use of pink porcelain Porcelain has been baked onto the custom abutment
  • 31. Custom abutments with screw retained restorations Excessive labial inclinations The axial wall lengths are frequently inadequate for effective cement retention
  • 32. Custom abutments with screw retained restorations Labial axial walls are insufficient to retain a cemented restoration.
  • 33. Custom abutments with screw retained restorations
  • 34. Custom abutments with screw retained restorations
  • 35. Limits of Cement Retention Implants angled excessively to the labial or buccal v  Axialwall height limits the retention v  Shortest wall determines retention v  Minimum height of axial wall – 4 mm.
  • 36. Fit isn’t as critical ? Really? The assumption is that a misfit is just a passive cement gap with no negative consequences The restoration appears to precisely fit the master cast. However, will it fit the patient?
  • 37. Fit isn’t as critical ? Really? The assumption is that a misfit is just a passive cement gap with no negative consequences Unfortunately, this was not the case. If you cement this case there will be a sizable cement margin and you may overload the implants.
  • 38. Fit isn’t as critical ? Really? The assumption is that a misfit is just a passive cement gap with no negative consequences When the impression is made with linked open tray impression copings and the original restoration placed on the master cast the misfit is profound
  • 39. Fit isn’t as critical ? Really? The assumption is that a misfit is just a passive cement gap with no negative consequences New Bridge on accurate model.
  • 40. Emergence Profile Compromises Screw vs Cement Retained v  Cemented crown contour v  Screw retained crown begins ideally just apical to the can carry ideal contour marginal soft tissue, which can all the way to the head produce the classic “pancake” crown. of the implant (arrow)
  • 41. Summary: Limits of Cement Retention v  Axialwall height limits the retention v  Shortest wall determines retention v  Minimum height – 4 mm.
  • 42. Cementation The main issues are: v  Cement retention (pack retraction chord before cementation) v  Quality of retention (axial wall length) v  Lack of retrievability
  • 43. Arguments in favor of screw retained restorations v  Carry restoration more subgingivally than we can predictably remove cement. v  Formore ideal emergence profile and contour. v  Avoid trapping cement subgingivally v  More predictable seating of bridge pontic or even single tooth given the gingival contour. v  Better retention particularly when a cemented restoration would have a very short axial wall. v  Easier to restore when there is limited inter- occlusal or restorative space
  • 44. Next Generation of the UCLA Abutment Shape Memory Sleeve (Seo and Wu) ❖  The treatment procedure is similar to current methods
  • 45. The Next Generation of the UCLA Abutment Shape Memory Sleeve “Nitinol” (Nickel titanium alloy)
  • 46. Next Generation of the UCLA Abutment (Seo and Wu) Issues v Is Nitinal biocompatible? v Will the increase in temperature during activation be transmitted to the fixture, abutment and underlying tissues? v What is the quality of the retention? v Will it stand up to repeated occlusal loading v Galvanic reactions?
  • 47. Next Generation of the UCLA Abutment Safety of Shape Memory Alloy, “Nitinol” (Nickel titanium alloy) ‣  Nitinol is safe and bio-compatible ‣  Many devices are approved by FDA ‣  Economical to manufacture Heart balloon Arch bars Heart stent
  • 48. Release of the crown Shape memory device is activated by heat Activation brings the temperature up to 55 degrees Centigrade. It’s a shape change
  • 49. Next Generation of the UCLA Abutment Measurement of Temperature Rise in Abutment and Implant Fixture During Heat Activation
  • 50. Next Generation of the UCLA Abutment Measurement of Temperature Rise in Abutment and Implant Fixture During Heat Activation ΔT, implant fixture (°C) ΔT, abutment (°C) Passive air cool 1.4 2.8 Forced air cool 0.3 2.1
  • 51. Next Generation of the UCLA Abutment Measurement of Retention Strength Temperature Chamber
  • 52. Next Generation of the UCLA Abutment Measurement of Retention Strength - Set up - Assembly: implant Saline chamber: body temperature fixture + abutment + RODO sleeve
  • 53. Measurement of Retention Strength Results Min - Max. (N) Provisional cement 30 - 250 Zinc phosphate 330 - 346 RODO Device! 275 - 1,500! Shape memory sleeve after the test
  • 54. Measurement of Maximum Compressive Strength ISO 14801 Guideline - Set up - Assembly: implant fixture + Saline Chamber abutment + RODO sleeve (Body Temperature)
  • 55. Measurement of Maximum Compressive Strength Results Maximum Abutment Strength Failed at abutment- *No failure in the RODO Device implant fixture interface 750 N Failure of Conventional Abutments : 800 ~ 1,000 N Screw fractured
  • 56. Next Generation of the UCLA Abutment ISO 14801:2007-11-15 Dynamic Fatigue Test for Endosseous Dental Implants Failed at abutment- Displacement controlled fatigue performance implant fixture interface *No failure in the RODO Device 50 - 400 Screw failed at 6000 cycles Minimum # of cycles
  • 57. Next Generation of the UCLA Abutment (Seo ,Wu and Shah) Upcoming Studies v  Galvanic testing v  Short term IRB trial at UCLA School of Dentistry (Kumar Shah and Neil Garrett) v  Long term IRB trials at UCLA, other universities and private clinics in the US commenced summer 2011. Patients with known nickel allergies not candidates
  • 58. Platform Reduction and Etiology of Marginal Bone Loss around Implants Original Branemark design lost bone down to the first thread. Why? v  Thread design? v  Surface topography? v  Conical implant seal? v  Design of the neck? v  Platform reduction? (switching)
  • 59. Etiology of the initial bone loss around implants v  Almost immediately the original “Branemark” design lost bone down to the first thread. v  Other designs such as the “Astra” design appear to retain their bone levels v  What is the evidence? What are the likely explanations for this difference?
  • 60. Etiology of initial bone loss around implants Angulation of the neck v An implant is torqued into position with 45 Newtons v However, the torque values around the neck of the implant imbedded in the cortical bone is probably closer to 100 Newtons. v Will these values predispose to resorption to the cortical bone around the neck of the implant when the angle of the implant is acute?
  • 61. Etiology of initial bone loss around implants v Angulation of the neck v Whenocclusal loads are applied will the implants with acute angles atop of the implant overload the bone in this area precipitating a resorptive remodeling response and bone loss?
  • 62. Platform reduction (platform switching) Courtesy G. Perri Courtesy C. Stanford v Note the bone levels atop the implant. v Is it the result of the horizontalization of the biologic width (platform reduction)?
  • 63. Platform reduction (platform switching) Courtesy G. Perri Courtesy C. Stanford The evidence is far from clear. v In these examples the angulation of the top of the implant may be the more important factor v In addition in both these implant systems the micro-rough surface was extended to the top of the implant. This also, may contribute to the maintenance of bone levels atop the implant.
  • 64. Angulation of the neck v  Some authors have maintained that the angulation atop the implant is the most important factor. (Braun, et al, 2006; Iacono et al , 2006) v  They attribute the maintenance of bone atop of the implant to the so-called “negative” slope (dotted lines).
  • 65. The presence of micro-threads Courtesy G. Perri Courtesy C. Stanford Is it the result of the microthreads around the neck of the implant?
  • 66. Internal interlocking vs external hex system Conical seal v  Allabutment – implant fixture interfaces demonstrate gaps upon loading from 10-50 microns. The original external hex systems demonstrates the largest gaps during flexure. v  Do these gaps harbor micro-organism which in turn precipitate an inflammatory response leading to bone loss around the neck of the implant?
  • 67. Marginal Bone Loss Based on a Med Line search, a review of the literature indicated that no implant system, surface or design was found superior with regards to marginal bone loss (Abrahamsson and Berhlundh, 2009)
  • 68. Platform Switching (Reduction) Will this type of implant fixture – abutment configuration minimize the bone loss around the neck of implants? v Basedon a review by Bateli and Strub (2011) “the current literature provides insufficient evidence about the effectiveness of any specific modification in the implant neck area in preserving marginal bone or preventing marginal bone loss”
  • 69. One piece systems Nobel direct and similar one piece systems There are no gaps developing between an abutment and fixture. Why the bone loss? Most have modern surfaces. Many were immediately provisionalized and loaded with cement retained restorations. In many cases the cement extended down to the boney levels v Aninflammatory response was initiated which was progressive and irreversible leading to extensive bone loss.
  • 70. Zirconium Implant Fixtures (Strub et al, 2010) v  Has been promoted for use in the esthetic zone v  Biocompatible " Histology similar to titanium – about 60% bone implant contact area " Anchorage is similar to titanium v  Microrough surfaces the best v  Success rates equivalent to titanium v  UV exposure makes the surface more bioreactive v  Fractures " One piece system – fractures at ¼ the load compared to titanium " Two piece systems fracture at 1/6th the load compared to titanium " Alumina reinforced zirconium is stronger Not ready for clinical use. Some people believe that zirconium implants will eventually disappear from the market.
  • 71. Zirconium abutments and frameworks Used in the esthetic zone Abutments l  Less plague adherence l  More esthetic l  Higher fracture rate Frameworks l  High incidence of chipping of porcelain off the zirconium frameworks l  Not recommended for posterior teeth Courtesy Dr. A. Sharma
  • 72. v  Visitffofr.org for hundreds of additional lectures on Complete Dentures, Implant Dentistry, Removable Partial Dentures, Esthetic Dentistry and Maxillofacial Prosthetics. v  The lectures are free. v  Our objective is to create the best and most comprehensive online programs of instruction in Prosthodontics