EFSA Journal 2014;12(7):3745 
Suggested citation: EFSA AHAW Panel (Animal Health and Welfare), 2014. Scientific Opinion on electrical requirements 
for poultry waterbath stunning equipment. EFSA Journal 2014;12(7):3745, 18 pp. doi:10.2903/j.efsa.2014.3745 
Available online: www.efsa.europa.eu/efsajournal 
© European Food Safety Authority, 2014 
SCIENTIFIC OPINION 
Scientific Opinion on electrical requirements for poultry waterbath stunning equipment1 
EFSA Panel on Animal Health and Welfare (AHAW)2, 3 
European Food Safety Authority (EFSA), Parma, Italy 
ABSTRACT 
The European Commission (EC) requested that the EFSA Panel on Animal Health and Welfare (AHAW Panel) delivers a scientific opinion on a study that proposes parameters for poultry electrical waterbath stunning different to those laid down in Council Regulation (EC) No 1099/2009 on the protection of animals at the time of killing. The submitted study reports upon the use (mean + SD) of a current of 104.00 ± 3.88 mA, a voltage of 125.86 ± 3.28 V and a frequency of 589.78 ± 0.63 Hz using a square wave in alternating current (AC) with a 50 % duty cycle. These conditions were applied for 15 seconds to chickens under laboratory and slaughterhouse conditions. The submitted study was peer-reviewed by the AHAW Panel in the manner detailed in its ‘Guidance on the assessment criteria for studies evaluating the effectiveness of stunning intervention regarding animal protection at the time of killing’. The methodology and the data reported do not provide conclusive evidence that the combination of the proposed electrical frequency and current induced unconsciousness without exposing the chickens to avoidable pain and suffering. Further, some chickens did not remain unconscious for a sufficient time to prevent avoidable pain and suffering during slaughter. Because the information provided in the study was incomplete and insufficient, it did not pass the eligibility phase of the assessment. In the context of Directive 2010/63/EU on the protection of animals used for scientific purposes, and current scientific evidence, a frequency of 600 Hz with a current of 104 mA does not result in efficient stunning of poultry. Therefore, additional research into these stunning parameters is not recommended. 
© European Food Safety Authority, 2014 
KEY WORDS 
poultry, waterbath, electric, stunning, parameter, welfare, EEG 
1 On request from European Commission, Question No EFSA-Q-2014-00089, adopted on 25 June 2014. 
2 Panel members: Edith Authie, Charlotte Berg, Anette Bøtner, Howard Browman, Ilaria Capua, Aline De Koeijer, Klaus Depner, Mariano Domingo, Sandra Edwards, Christine Fourichon, Frank Koenen, Simon More, Mohan Raj, Liisa Sihvonen, Hans Spoolder, Jan Arend Stegeman, Hans-Hermann Thulke, Ivar Vågsholm, Antonio Velarde, Preben Willeberg and Stéphan Zientara. Correspondence: ALPHA@efsa.europa.eu 
3 Acknowledgement: The Panel wishes to thank the members of the Working Group on electrical requirements for poultry waterbath stunning equipment: Howard Browman, Mohan Raj and Antonio Velarde for the preparatory work on this scientific opinion and EFSA staff: Renata Leuschner and Denise Candiani for the support provided to this scientific opinion.
Electrical poultry waterbath stunning parameters 
EFSA Journal 2014;12(7):3745 2 
SUMMARY 
Following a request from the European Commission, the EFSA Panel on Animal Health and Welfare (AHAW) was asked to deliver a scientific opinion on electrical requirements for waterbath stunning equipment. The AHAW Panel addressed the terms of reference (ToRs) as provided by the European Commission, based upon information received from a third country. The Commission requested the EFSA to review the scientific publication provided and to assess to what extent the electrical parameters proposed for stunning poultry are able to provide a level of animal welfare at least equivalent to that ensured by the currently allowed methods and, in case of favourable reply, under what conditions. 
Following review of the provided information and evaluating the stunning procedure applied and its welfare outcome (ToR1) it was concluded that the submitted study does not provide enough scientific information upon which to base an assessment of the scientific approach and parameters suggested. Consequently, a full assessment of the animal welfare implications of the proposed stunning procedure was not undertaken (ToR2) and a revision of the electrical requirements for waterbath stunning equipment laid down in Table 2 of Chapter II of Annex I to Council Regulation (EC) No 1099/2009 is not recommended (ToR3). 
Nonetheless, the information provided was sufficient to conclude that the birds were not rendered immediately unconscious by the intervention. Application of a current less than that required to induce immediate unconsciousness causes pain, distress and suffering. The study failed to demonstrate absence of pain and suffering until onset of unconsciousness. The minimum duration of unconsciousness was too short to ensure unconsciousness until death by bleeding. 
In multiple birds waterbath stunning situations, such as the one assessed here, the electrical resistance varies widely between birds making it impossible to deliver the same constant and predetermined current to each individual bird. The complexity of such multiple bird electrical waterbath stunning systems used in poultry slaughterhouses is not conducive to maintaining good animal welfare and, therefore, alternatives should be developed/implemented. 
Studies such as the one assessed here should consider the internationally accepted basic principle referred to as the 3 Rs (replacement, reduction and refinement, according to Directive 2010/63/EU), which recommend approaches to minimize the use of animals for experimental purposes in line with the European Regulation on protection of animals used for scientific purposes.
Electrical poultry waterbath stunning parameters 
EFSA Journal 2014;12(7):3745 3 
TABLE OF CONTENTS 
Abstract .................................................................................................................................................... 1 
Summary .................................................................................................................................................. 2 
Table of contents ...................................................................................................................................... 3 
Background as provided by the European Commission ........................................................................... 4 
Terms of reference as provided by European Commission ...................................................................... 4 
Assessment ............................................................................................................................................... 5 
1. Introduction ..................................................................................................................................... 5 
2. Documentation provided to EFSA ................................................................................................... 5 
3. Assessment approach ....................................................................................................................... 6 
4. Assessment of eligibility criteria ..................................................................................................... 6 
4.1. Intervention of study one ........................................................................................................ 6 
4.2. Outcome of study one ............................................................................................................. 7 
4.2.1. Onset of unconsciousness and insensibility ........................................................................ 7 
4.2.2. Study under controlled laboratory conditions ..................................................................... 7 
4.2.2.1. Conclusion ................................................................................................................. 8 
4.2.3. Study under slaughterhouse conditions .............................................................................. 8 
4.2.3.1. Conclusion ................................................................................................................. 9 
4.2.4. Absence of pain, distress and suffering until the loss of consciousness and sensibility ..... 9 
4.2.4.1. Conclusion ................................................................................................................. 9 
4.2.5. Duration of unconsciousness and insensibility ................................................................... 9 
4.2.5.1. Conclusion ............................................................................................................... 10 
4.3. Assessment of study two providing details on measurement of the electric current that flows into the bird brain ............................................................................................................................... 10 
5. Reporting quality ........................................................................................................................... 10 
5.1. Assessment of the reporting quality of the submitted studies based on the selected parameters .......................................................................................................................................... 10 
6. Methodological quality .................................................................................................................. 10 
6.1. Quality assessment of the internal validity of the submitted studies .................................... 10 
Conclusions and recommendations ........................................................................................................ 10 
References .............................................................................................................................................. 11 
Appendix ................................................................................................................................................ 13 
Abbreviations ......................................................................................................................................... 18
Electrical poultry waterbath stunning parameters 
EFSA Journal 2014;12(7):3745 4 
BACKGROUND AS PROVIDED BY THE EUROPEAN COMMISSION 
Table 2 of Chapter II of Annex I to Council Regulation (EC) No 1099/20094 on the protection of animals at the time of killing sets out the average values per animal of electrical requirement which must be used when stunning chickens, turkeys, ducks, geese and quails using waterbath stunning equipment. 
These requirements are based on two previous EFSA opinions on the subject adopted respectively in 2004 and 2006 (EFSA, 2004, 2006). In the meantime the EFSA issued another opinion on the issue in 2012 (EFSA AHAW Panel, 2012). 
Article 2 (f) of Council Regulation (EC) No 1099/20094 defines ‘stunning’ as ‘any intentionally induced process which causes loss of consciousness and sensibility without pain including any process resulting in instantaneous death’. Furthermore, Article 4 states that ‘The loss of consciousness and sensibility should be maintained until the death of the animal’. 
Article 4 (2) of the same Regulation4 allows the Commission to amend its Annex I so as to take into account scientific and technical progress on the basis of an opinion of the EFSA. Any such amendments shall ensure a level of animal welfare at least equivalent to that ensured by the existing methods. 
The Commission has received information from a third country which may justify amending these parameters (submitted study). 
In order to reply to this request, the Commission would like to request the EFSA to review the scientific publication provided and assess to which extent the electrical parameters proposed for stunning poultry are able to provide a level of animal welfare at least equivalent to that ensured by the currently allowed methods and, in case of favourable reply, under which conditions. 
TERMS OF REFERENCE AS PROVIDED BY EUROPEAN COMMISSION 
The Commission therefore considers it opportune to request the EFSA to give an independent view on the electrical requirements for stunning equipment applicable for poultry. 
Review if the study provides sufficient scientific details as to evaluate the stunning procedure applied and its welfare outcome; In case of favourable reply, carry out a full welfare assessment of the animal welfare implications of the proposed stunning procedure, taking into account other relevant scientific references; Recommend, if necessary, a revision of the electrical requirements applicable for waterbath stunning equipment laid down in Table 2 of Chapter II of Annex I to Council Regulation (EC) No 1099/20094. 
4 Council Regulation (EC) No 1099/2009 of 24 September 2009 on the protection of animals at the time of killing. OJ L 303, 18.11.2009, p. 1-30.
Electrical poultry waterbath stunning parameters 
EFSA Journal 2014;12(7):3745 5 
ASSESSMENT 
1. Introduction 
Electrical waterbath stunning is permitted for use in poultry when the technical criteria described in Annex I of Council Regulation (EC) No 1099/20094 are fulfilled. The legislative requirements prescribe that the brain should be exposed to a current generating generalised epileptiform activity in the EEG and possibly fibrillation or stopping of the heart. For stunning interventions that do not induce immediate unconsciousness, the alternative procedure should ensure 1) absence of pain, distress and suffering until the onset of unconsciousness, and 2) that the animal remains unconscious and insensible until death. 
A study researching modified electrical parameters of waterbath stunning should record the intervention applied to individual animals. The legislation states that the key parameters are minimum current, minimum voltage, maximum frequency, frequency of calibration of the equipment, prevention of electrical shocks before stunning, minimising pain at shackling, optimisation of the current flow, maximum shackle duration before the waterbath, minimum time of exposure for each animal, immersion of the birds up to the base of the wings and maximum stun-to-stick/kill interval(s) for frequency(ies) over 50 Hz. Studies analysing a modification of a currently permitted method need to describe all of the key legal parameters. Some parameters are divided into several detailed components - as specified in the Guidance document (EFSA AHAW Panel, 2013a) - to ensure a comprehensive description of the applied stunning intervention (Table 1 in the Appendix). In addition, the throughput rate should be specified where appropriate (e.g. field studies). 
EFSA herein presents an opinion on the study received for a scientific evaluation entitled ‘Study of chicken stunning using electroencephalogram’ in a manner consistent with the terms of reference provided by the European Commission. EFSA assessed only the stunning procedure itself and did not take into account any pre-stunning phases. A full assessment of the welfare implications, which would need to take into account both pre-stunning and stunning phases of the slaughter process, is beyond the scope of this mandate. 
2. Documentation provided to EFSA 
The Commission has received information from a third country entitled ‘Study of chicken stunning using electroencephalogram’ in February 2014. This study5 was sent to EFSA for a scientific evaluation and comprises an introduction (part 1), materials and methods (part 2) for two studies entitled in the document ‘study 1’ and ‘study 2’, results (part 3) for the two studies, a conclusion (part 4), a table entitled key parameters and related specifications (part 5) and a reference Section with literature (part 6): 
STUDY 1 – Composed of the Sections entitled ‘Evaluations of the stun without sticking’ comprised of the sub-sections ‘test carried out on laboratory’, ‘test carried out on slaughterhouse’; followed by a Section ‘continuous evaluation of EEG of chickens during bleeding’ 
STUDY 2 – Provides details on measurement of the electric current that flows into the bird brain. 
5 by Ernane José Xavier da Costa1; Sulivan Pereira Alves2; Paulo Sergio Rosa3; Gerson Scheuermann4; Arlei Coldebella5; Leonardo Thielo de La Vega6; Luis Teixeira7 [1PhD. Professor. University of São Paulo, USP; 2D.Sc. Technical Coordinator, União Brasileira de Avicultura; 3D.Sc. Researcher; EMBRAPA Swine and Poultry; 4PhD. Researcher - EMBRAPA Swine and Poultry; 5Dsc. Researcher, EMBRAPA Swine and Poultry; 6Bachelor Veterinary Medicine, Quality Planning, Brasil Foods/BRF; 7Bachelor Veterinary Medicine, Federal Agriculture and Livestock Inspector, Permanent Technical Commission of Animal Well-Being, CTBEA/MAPA]
Electrical poultry waterbath stunning parameters 
EFSA Journal 2014;12(7):3745 6 
3. Assessment approach 
The assessment of the submitted studies was carried out in a manner analogous to that described in the guidance document (EFSA AHAW Panel, 2013a). The assessment was first conducted independently by each working group (WG) member. The individual assessments were then discussed to reach a consensus on issues over which the experts had expressed different opinions. 
The assessment focuses initially on term of reference one (ToR1). Each of the three WG experts independently reviewed if the eligibility criteria set out in the guidance for electrical waterbath stunning (EFSA AHAW Panel, 2013a) were met by the study. Since the submitted study did not meet the eligibility criteria, neither a full assessment of the animal welfare implications of the proposed alternative stunning intervention (ToR2), nor a systematic review of the electrical requirements applicable for waterbath stunning equipment (ToR3) were undertaken. 
4. Assessment of eligibility criteria 
4.1. Intervention of study one 
The information provided in the submitted study was assessed following the procedure detailed in the EFSA guidance (EFSA AHAW Panel, 2013a). A detailed evaluation of the reported parameters in the submitted study is presented in Table 1 (Appendix). The basis for the conclusions drawn by the AHAW Panel is summarised below. Only those aspects that were not considered adequate are commented upon. 
Importantly, the Table presented in Section 5 of the submitted study does not specify whether the information provided is related to the laboratory study, the study under slaughterhouse conditions, or both. Nor is this Table referred to in the body of the text. As a result, it was impossible to assess the information presented in Section 5. Therefore, the assessment below, and in the Tables in the Appendix, was restricted to information that was supported by descriptive text in the body of the manuscript. 
The parameters of the intervention were presented in an inconsistent and contradictory manner. It was not possible to unequivocally determine which intervention parameters were applied when and where during the study. Key parameters (see Table 4, Section 3.1.2.2 of the EFSA guidance (EFSA AHAW Panel, 2013a)) were not described adequately - for example, calibration of the equipment, optimisation of the current flow, information on the concentration and type of salt used in the waterbath (chemical formula), information on the cleanliness of chickens, etc. 
The electrical stunning equipment is not adequately described. For example, it is not clear whether a constant voltage source was used to stun broilers individually and how this minimum voltage was set to deliver the minimum current to birds. In the manuscript, it is mentioned (Section 2.1.1.1) that the electrical parameters were verified using a hand-held digital multimeter (usually called ‘Galinha Electrônica’) made by Fluxo® - however, neither the manner in which this was done, nor the results of the measurements, are provided. 
Information provided in the submitted manuscript regarding the maximum stun-to-stick/kill interval(s) for frequency over 50 Hz was insufficient regarding the duration of unconsciousness. The minimum duration of unconsciousness induced by stunning should be longer than the sum of time interval between the end of stunning and neck cutting and the time it takes for death to occur due to blood loss. 
The authors state that the same procedures were followed in the slaughterhouse as in the laboratory (Section 2.1.1.2). However, besides this statement, no further description was provided, making it impossible to assess the slaughterhouse study.
Electrical poultry waterbath stunning parameters 
EFSA Journal 2014;12(7):3745 7 
4.2. Outcome of study one 
4.2.1. Onset of unconsciousness and insensibility 
Research studies evaluating stunning methods require well controlled experiments under laboratory conditions as a first step to characterise the animals’ responses (unconsciousness, absence of pain if the induction of unconsciousness is not immediate) using the most sensitive and specific methods available (e.g. behaviour, EEG, physiological response) and to establish the correlations between these measurements and non-invasive animal-based parameters that can be applied in slaughterhouses (EFSA AHAW Panel, 2013a). Alternative stunning methods or parameters should disrupt the neuronal function and, thereby, render animals unconscious and insensible. The extent of disruption caused by a stunning intervention, and the induction of unconsciousness and insensibility, are best demonstrated using EEGs and ECoGs (EFSA, 2004, 2013; EFSA AHAW Panel, 2013a,b,c). As described in the EFSA guidance (EFSA AHAW Panel, 2013a), it is acceptable that studies reporting interventions assess the onset of unconsciousness as this state is always accompanied by the onset of insensibility. 
In studies under laboratory conditions, unconsciousness and insensibility can be determined by the following EEG patterns: induction of a generalised epileptiform activity in the brain, which can be recognised from the predominance of 8-13 Hz high-amplitude EEG activity in mammals and possibly slightly lower frequency in poultry which should be followed by a quiescent EEG, or an immediate onset of a quiescent EEG, or abolition of visual or auditory evoked responses or potentials in the brain immediately after the stunning. 
4.2.2. Study under controlled laboratory conditions 
The information provided in the submitted study was assessed following the procedure detailed in the EFSA guidance (EFSA AHAW Panel, 2013a). A detailed evaluation of the reported parameters in the submitted study is presented in Table 2 (Appendix). The basis for the conclusions drawn by the AHAW Panel is summarised below. Only those aspects that were not considered adequate are commented upon. 
EEG recording and analysis – The results are inconsistent with the methodology described in the method Section. It is stated in the method Section that the EEG signals were analysed and filtered into four frequency bands but data relevant to only one of the frequency (delta) band is reported in the results Section, although no conclusions about the predominance of delta bands is provided. In addition, the implications of changes in the EEG frequency bands for the degree of unconsciousness are neither reported nor discussed. The occurrence of quiescent EEG with less than 10 % of the pre- stun EEG total power following the epileptiform activity is not considered/demonstrated as an indicator of unconsciousness. 
EEG results - The results in Table 3 of the submitted study show that there is no loss of consciousness within one second which should be the case according to the guidance (EFSA AHAW Panel, 2013a). An exposure to the stunning parameters for 15 seconds prior to the onset of unconsciousness is unacceptably long. There is no information on the absence of pain to the animals before the onset of unconsciousness. Therefore, the intervention does not fulfil the requirements of stunning, i.e. induction of immediate loss of consciousness without causing avoidable pain, distress and suffering. 
Animal-based measures to detect onset of unconsciousness (EFSA AHAW Panel, 2013a) are immediate onset of tonic seizures and apnoea following electrical water bath stunning – these were not reported in the study. Instead, the study reports resumption of breathing as the earliest sign of recovery of consciousness. However, in the absence of any evidence of epileptiform activity in the brain, or tonic seizures, the resumption of breathing alone cannot be used as an indicator of a return to consciousness. This is because electro-immobilisation can also produce apnoea followed by recovery of breathing without loss of consciousness. Therefore, recovery of breathing on its own is not a reliable indicator.
Electrical poultry waterbath stunning parameters 
EFSA Journal 2014;12(7):3745 8 
According to Council Regulation (EC) No 1099/20094, electrical stunning of animals, including waterbath stunning of poultry, must induce generalised epileptiform activity in the EEG. This is because the occurrence of epileptiform EEG activity indicates successful induction of unconsciousness following electrical stunning. 
Scientific literature concerning epilepsy in humans indicates that focal or partial epilepsy involving a group of neurons, region of the brain or one cerebral hemisphere is not always associated with unconsciousness (e.g. see Lux et al., 2002). On the other hand, a kind of generalised epilepsy, involving both cerebral hemispheres, that is always associated with unconsciousness in humans is grand mal (e.g. ILAE, 1981). Techniques for the classification of EEG signals for identification of epilepsy in humans have been developed (Kulkarni, 2013), but have not been tested under electrical stunning situations. Nevertheless, occurrence of generalised epilepsy following electrical stunning can be recognised from the occurrence of highly synchronised 8 to 13 Hz electrical activity in the EEG of animals. However, there is some indication that a low frequency epileptiform activity occurs in poultry (Gregory, 1986). In any case, the epileptiform activity should always be followed by a quiescent EEG which is less than 10 % of the pre-stun power content (EFSA AHAW Panel, 2013a). 
4.2.2.1. Conclusion 
The evidence presented in the submitted study showed that the intervention did not produce unconsciousness without causing avoidable pain, distress and suffering. 
4.2.3. Study under slaughterhouse conditions 
The information provided in the submitted study was assessed following the procedure detailed in the EFSA guidance (EFSA AHAW Panel, 2013a). A detailed evaluation of the reported parameters in the submitted study is presented in Table 3 (Appendix). The basis for the conclusions drawn by the AHAW Panel is summarised below. Only those aspects that were not considered adequate are commented upon. 
Only one bird at a time was monitored - this is not representative of real slaughterhouse conditions, under which several chickens are stunned in the waterbath simultaneously. Therefore, this study cannot be considered representative of commercial slaughterhouse conditions. 
Start and end of EEG measurement - No additional details are reported beyond those provided for the laboratory study (which were inadequate – see above). 
EEG measurement - Exposure time is not reported. The results of EEG analysis considered the drop in power of the 2-30 Hz band in 1 second epochs and the drop in the ratio of the power in the delta band compared to the other bands before and after stunning. This is not mentioned in the method Section of the submitted study and these EEG parameters were not evaluated in the laboratory study. 
EEG recoding and analysis - Changes in the frequency bands are not always reliably demonstrated. The requirement is epileptiform EEG following stunning and the parameters are not sufficient to achieve this in the birds. It is reported that 15 seconds application produced epileptiform EEG for 15 seconds, but suppressed EEG did not follow. 
EEG results - Figure 7 of the submitted study is not clear regarding the number of birds used i.e. n = 32, whereas in the text (Section 2.1.1.2) it is stated that 30 animals were tested. Data on the average duration of unconsciousness presented in this figure is not based on the duration of epileptiform EEG. 
The EEG trace presented in Figure 11 of the submitted study does not show pre-stun EEG and therefore it is difficult to ascertain whether the ictal EEG is indeed epileptiform activity.
Electrical poultry waterbath stunning parameters 
EFSA Journal 2014;12(7):3745 9 
Animal-based measures to detect onset of unconsciousness – As noted above, recovery of breathing on its own is not a reliable indicator. Further, the results presented in Figure 9 of the submitted study are unclear (the number of n = 71 is not clear because in the method Section 2.1.1.2 it is stated that 30 birds were used in the commercial study under slaughterhouse conditions). 
Additional considerations - Commercial multiple bird electrical waterbath stunners contain many birds (e.g. 30). As birds enter a stunner supplied with a constant voltage, they form a continuously changing parallel electrical circuit (Sparrey et al., 1993). Under this situation, each bird will receive a current inversely proportional to the electrical resistance or impedance in the pathway. The effective electrical impedance can vary between birds, usually 1000 to 2600 Ohms in broilers and 1900 and 7000 Ohms in layer hens (Schütt-Abraham et al., 1987; Schütt-Abraham and Wormuth, 1991). In fact, most of the electrical impedance in the pathway between the electrified water bath and the earth is attributed to poor contact between the legs of the bird and the metal shackles. The implication of this is that tighter shackle-leg fittings will reduce the electrical impedance at the expense of increased suffering due to pain. However, as a result of the variable electrical impedance, it will be impossible to deliver to each bird in a water bath stunner the pre-set minimum current necessary to achieve humane stunning (Sparrey et al., 1992). 
4.2.3.1. Conclusion 
The study carried out under slaughterhouse conditions applied the same intervention as the laboratory study. Therefore, it also fails to meet the eligibility criteria (EFSA AHAW Panel, 2013a). Further, since only one bird at a time was monitored, this study cannot be considered representative of commercial slaughterhouse conditions. 
4.2.4. Absence of pain, distress and suffering until the loss of consciousness and sensibility 
The information provided in the submitted study was assessed following the procedure detailed in the EFSA guidance (EFSA AHAW Panel, 2013a). A detailed evaluation of the reported parameters in the submitted study is presented in Table 4 (Appendix). The basis for the conclusions drawn by the AHAW Panel is summarised below. Not all parameters apply because electrical stunning must induce immediate loss of consciousness. In the event of a prolonged application of an electric current below the threshold necessary to produce unconsciousness will cause pain and suffering. Only those aspects that were not considered adequate are commented upon. 
There is no evidence that the proposed intervention induced immediate unconsciousness. 
No description was provided, for either the laboratory or slaughterhouse studies, of how birds were anaesthetised when they were implanted with two electrodes positioned under the skullcap through the skin and skull onto the brain lobes for EEG recording as outlined buy the authors. A reference to a standard protocol for EEG measurement was not present. 
4.2.4.1. Conclusion 
The results of study one showed clearly that the proposed electrical stunning parameters had to be applied for a minimum of 15 seconds to produce epileptiform activity in the EEG. This prolonged application of an electric current through the whole body of poultry, while the animal is still conscious, would cause pain, distress and suffering until the loss of consciousness. 
4.2.5. Duration of unconsciousness and insensibility 
Council Regulation (EC) No 1099/20094 states that unconsciousness and insensibility induced by stunning should last until the moment of death. Studies in a controlled environment should determine the duration of unconsciousness and insensibility using EEG. Based upon the obtained results (e.g. the shortest time to recovery of consciousness observed minus two standard deviations), the maximal stun-to-stick/-kill time interval can be defined that guarantees unequivocal loss of consciousness and sensibility until the moment of death (EFSA, 2004). The applicability of the stun-to-stick/-kill interval
Electrical poultry waterbath stunning parameters 
EFSA Journal 2014;12(7):3745 10 
should then be analysed under slaughterhouse conditions using indicators recognising recovery of consciousness and sensibility that correlate with EEGs as established in controlled environment studies. It is acceptable that studies on alternative stunning parameters assess only the duration of unconsciousness as this will always precede the recovery of sensibility. 
In the submitted study, EEG was recorded as an indicator of onset of unconsciousness and the resumption of rhythmic breathing was taken as an indicator of return of consciousness following stunning in the laboratory study and in the study under slaughterhouse conditions. The results regarding the variables used to assess the duration of unconsciousness are not reported. However, conclusions about the duration of unconsciousness appear to be based on the occurrence of delta EEG activity. The minimum duration of unconsciousness was reported to be 11 seconds, which is too short to permit a feasible stun-to-stick interval. Further, it is also doubtful that recovery of consciousness could be avoided prior to neck cutting and/or during bleeding. This interpretation is also supported by the data concerning time to resumption of breathing (Figure 9 in the submitted study). The minimum time to resumption of breathing was reported to be 8 seconds following stunning. 
4.2.5.1. Conclusion 
The submitted study clearly shows that the electrical stunning parameters failed to induce immediate unconsciousness in all the birds. The duration of unconsciousness achieved, even after 15 seconds of exposure to the electrical parameters, is not long enough to prevent recovery of consciousness before neck cutting or during bleeding. 
4.3. Assessment of study two providing details on measurement of the electric current that flows into the bird brain 
The description of the methods for study two (Section 2.2.1) states that 11 birds were individually stunned and slaughtered. Electrodes were implanted in the brain of each dead bird. The relevance and rationale for this approach that is put forward is unsubstantiated. The current registered in the brain of a dead bird is irrelevant because the crucial aspect for studies such as this is to demonstrate that the intervention renders the birds unconscious and insensible to pain until the time of death. In addition, measurements made in the brain of dead animals do not give any indication of whether live birds are subjected to avoidable pain or suffering prior to the induction of unconsciousness by the intervention. Therefore, this experiment does not provide any relevant additional information. 
5. Reporting quality 
5.1. Assessment of the reporting quality of the submitted studies based on the selected parameters 
The assessed studies did not pass the eligibility assessment and, therefore, reporting quality was not assessed (EFSA AHAW Panel, 2013a). 
6. Methodological quality 
6.1. Quality assessment of the internal validity of the submitted studies 
The assessed studies did not pass the eligibility assessment and, therefore, methodological quality was not assessed (EFSA AHAW Panel, 2013a). 
CONCLUSIONS AND RECOMMENDATIONS 
CONCLUSIONS The study does not provide enough information upon which to base an assessment of the scientific approach and parameters tested.
Electrical poultry waterbath stunning parameters 
EFSA Journal 2014;12(7):3745 11 
Nonetheless, the information provided was sufficient to conclude that the birds were not rendered immediately unconscious by the intervention. Application of a current less than that required to induce immediate unconsciousness causes pain, distress and suffering. The study failed to demonstrate absence of pain and suffering until onset of unconsciousness. The minimum duration of unconsciousness was too short to ensure unconsciousness until death by bleeding. 
RECOMMENDATIONS The complexity of multiple bird electrical waterbath stunning systems used in poultry slaughterhouses, such as the one assessed here, are not conducive to maintaining good animal welfare and, therefore, alternatives should be developed/implemented. Studies such as the one assessed here should consider the internationally accepted principles referred to as the 3 Rs (replacement, reduction and refinement according to Directive 2010/63/EU6) which recommend approaches to minimize the use of animals for experimental purposes in line with the European Regulation on protection of animals used for scientific purposes. 
REFERENCES 
ILAE (Commission on Classification and Terminology of the International League Against Epilepsy), 1981. Proposal for revised clinical and electroencephalographic classification of epileptic seizures. Epilepsia, 22, 489 - 501. 
EFSA (European Food Safety Authority), 2004. Welfare aspects of the main systems of stunning and killing the main commercial species of animals. The EFSA Journal 2004, 45, 1–29. 
EFSA (European Food Safety Authority), 2005. Aspects of the biology and welfare of animals used for experimental and other scientific purposes. The EFSA Journal 2005, 292, 1–46. 
EFSA (European Food Safety Authority), 2006. Opinion on the welfare aspects of the main systems of stunning and killing applied to commercially farmed deer, goats, rabbits, ostriches, ducks, geese and quail. The EFSA Journal 2006, 326, 1-18. 
EFSA (European Food Safety Authority), 2013. Outcome of a public consultation on the Draft Guidance on the assessment criteria for studies evaluating the effectiveness of stunning interventions regarding animal protection at the time of killing. EFSA supporting publication 2013:EN-530, 20 pp. 
EFSA AHAW Panel (EFSA Panel on Animal Health and Welfare), 2012. Scientific Opinion on electrical requirements for waterbath equipment applicable for poultry. EFSA Journal 2012;10(6):2757, 80 pp. doi:10.2903/j.efsa.2012.2757 
EFSA AHAW Panel (EFSA Panel on Animal Health and Welfare), 2013a. Guidance on the assessment criteria for studies evaluating the effectiveness of stunning interventions regarding animal protection at the time of killing. EFSA Journal 2013;11(12):3486, 41 pp. doi:10.2903/j.efsa.2013.3486 
EFSA AHAW Panel (EFSA Panel on Animal Health and Welfare), 2013b. Scientific Opinion on monitoring procedures at slaughterhouses for poultry. EFSA Journal 2013;11(12):3521, 65 pp. doi:10.2903/j.efsa.2013.3521 
Gregory NG, 1986. The physiology of electrical stunning and slaughter. In: Humane Slaughter of Animals for Food Humane Slaughter of Animals for Food: Proceedings of a Symposium Organized by Universities Federation for Animal Welfare, Held at the Meeting Rooms, Zoological Society of 
6 Directive 2010/63/EU of the European Parliament and of the Council of 22 September 2010 on the protection of animals used for scientific purposes. OJ L 276, 20.10.2010, p. 33-79.
Electrical poultry waterbath stunning parameters 
EFSA Journal 2014;12(7):3745 12 
London, Regent's Park, 18th September 1986. Universities Federation for Animal Welfare (Publishers), UK, 3-12. 
Kulkarni SPK, 2013. EEG signal classification for Epilepsy Seizure Detection using Improved Approximate Entropy. International Journal of Public Health Science, 2, 23 - 32. 
Lux S, Kurthen M, Helmstaedter C, Hartje W, Reuber M and Elger CE, 2002. The localizing value of ictal consciousness and its constituent functions: A video-EEG study in patients with focal epilepsy. Brain, 125, 2691- 2698. 
Ruffini G1, Wendling F, Merlet I, Molaee-Ardekani B, Mekonnen A, Salvador R, Soria-Frisch A, Grau C, Dunne S and Miranda PC, 2013. Transcranial current brain stimulation (tCS): models and technologies. IEEE Transactions on Neural Systems and Rehabilitation Engineering, 21, 333-345. 
Schütt-Abraham I, Wormuth HJ and Fessel J, 1987. Vergleichende Untersuchungen zur tierchutzgerechten Elektrobetäubung verschiedener Schlachtgeflügelarten. Berliner und Münchener Tierärztliche Wochenschrift, 100, 332-340. 
Schütt-Abraham I and Wormuth, H. J. 1991. Anforderungen an eine tierschutzgerechte elektrische Betäubung von Schlachtgeflügel. Rundeschau für Fleischhygiene und Lebensmittelüberwachung, 43, 7-8. 
Sparrey JM, Kettlewell PJ and Paice ME, 1992. A model of current pathways in electrical waterbath stunners used for poultry. British Poultry Science, 33, 907-916. 
Sparrey JM, Kettlewell PJ, Paice ME and Whetlor WC, 1993. Development of a constant current waterbath stunner for poultry processing. Journal of Agricultural Engineering Research, 56, 267- 274.
Electrical poultry waterbath stunning parameters 
EFSA Journal 2014;12(7):3745 13 
APPENDIX 
Assessment of eligibility criteria 
Table 1: Parameters assessed when applying a stunning intervention based on electrical waterbath stunning, based on Annex I of Council Regulation (EC) No 1099/20094 and on further details of requirements as determined by the EFSA guidance (corresponding to Table 4 (EFSA AHAW Panel, 2013a)). 
Parameter 
Component 
Description presented in study 
(all specifications should be in internationally recognised units) 
Information provided in Section 5 was not taken into account unless supported in the body of text in the submitted manuscript 
Fulfilment criterion (yes, no or not applicable) 
Minimum current 
(A or mA) 
Current type 
Alternating current 
Yes 
Waveform 
Square waves 50 % Duty cycle 
Yes 
Minimum 
current (a) 
104 ± 3,88 mA r.m.s 
Yes 
Minimum voltage (V) 
Exposed minimum voltage (V) (a) 
125,86 ± 3,88 r.m.s 
Yes 
Delivered minimum voltage (V) (a) 
Automatic process for voltage distribution according to the whole system resistance. 
No 
Frequency (Hz) 
Maximum frequency 
(Hz) 
590/600 
Yes 
Minimum frequency (Hz) 
589.78 ± 0.63 
Yes 
Frequency of calibration of the equipment 
In the manuscript, Section 2.1.1.1 it is mentioned that ‘the electrical parameters were verified using a hand-held digital multimeter (usually called ‘Galinha Electrônica’) made by Fluxo® 
No 
Prevention of electrical shocks before stunning 
None 
Not applicable 
Minimising pain at shackling 
None 
Not applicable
Electrical poultry waterbath stunning parameters 
EFSA Journal 2014;12(7):3745 14 
Table 1: Parameters assessed when applying a stunning intervention based on electrical waterbath stunning, based on Annex I of Council Regulation (EC) No 1099/20094 and on further details of requirements as determined by the EFSA guidance (corresponding to Table 4 (EFSA AHAW Panel, 2013a)) (continued) 
Parameter 
Component 
Description presented in study 
(all specifications should be in internationally recognised units) 
Information provided in Section 5 was not taken into account unless supported in the body of text in the submitted manuscript 
Fulfilment criterion (yes, no or not applicable) 
Optimisation of the current flow 
Shackles 
Wetting the leg shackle contact 
Contact with earth bar 
None 
No 
Waterbath and electrode characteristics 
None 
No 
Water conductivity 
None 
No 
Electricity source characteristics 
None 
No 
Electrical resistance/impedance 
Mixed flocks – male and female, average 3.3 kg, Ross and Cobb strains 
No 
Maximum shackle duration before stunning 
None 
No 
Minimum time of exposure for each bird 
According to Table 3, exposure time varied between 1 and 15 seconds in the laboratory study. Only 15 seconds exposure produced epileptiform activity in all the birds (n = 5). 
No. 
Immersion of the birds up to the base of the wings 
None 
No 
Maximum stun-to- stick/kill interval(s) for frequency over 50 Hz(a, b) 
In the method Section 2.1.2 it is stated that the birds underwent ventral cut 10 seconds after leaving the waterbath. In the results Section it is mentioned that 
bleeding takes place within 12, 10 and 8 seconds, respectively, after stunning (text Section 3.1.1.2 ‘physical signs’). 
No 
(a): Provide information on mean or median and range and standard deviation or interquartile range. 
(b): In case of simple stunning.
Electrical poultry waterbath stunning parameters 
EFSA Journal 2014;12(7):3745 15 
Table 2: Information provided in the laboratory study by the submitted study in relation to the onset of unconsciousness and insensibility (3.2.1 of EFSA guidance (EFSA AHAW Panel, 2013a)) 
Laboratory study 
Information provided in the submitted manuscript 
Is the criterion described/met adequately? 
(yes, no or not possible to assess) 
Start and end of EEG measurement 
In the submitted study the information is provided that the EEG was recorded 80 seconds before and 80 seconds after stunning before sticking (Section 2.1.1.1). 
Yes 
EEG measurement 
For the EEG registration, the birds were individually implanted with 2 needle electrodes 
(55 % silver, 21 % copper, 24 % zinc of 10 mm x 1.5 mm diameter) positioned under the skullcap through the skin and skull onto the brain lobes (0.3 cm left and right of the sagittal suture and 0.5 mm toward an imaginary transverse line at the caudal margin of the eyes). The electrodes were sealed using adhesive tape. 
Yes 
EEG recording analysis 
Information from last paragraph of Section 2.1.1.1: The EEG was collected at a sample frequency of 120 Hz and the digital signal obtained was processed using fast Fourrier transformation (FFT), implemented using the MATLAB tool to obtain the frequency spectrum of different stretches associated with different events on the EEG. Several successive artifact-free stretches were also analyzed and filtered into four frequency bands: delta (0.3-4 Hz), theta (4-8 Hz), alpha (8-12 Hz) and beta (12-30 Hz). 
Elliptical filters integrated onto a visual tool developed at the MATLAB® were used. In each of these frequency bands, the energy of the signal obtained was calculated using MATLAB® signal processing toolbox. 
Spike-and-slow-wave-complex (SASWC) (known as petite mal) and spike-or-sharp-wave (SOSW) (common to several different types of epilepsy) are referred in the results Section (3.1.1.1) 
No 
EEG results 
In the submitted study one sample recording of epileptic EEG obtained after 15 seconds stunning is shown in Figure 5. The epileptic ictal stage has 12 seconds of duration. However the legend of the figure mentions 15 seconds of electrical exposure. 
Epileptic patterns in the EEG were detected by analyzing the spectral power density. The results show that the electrical parameters tested will induce epilepsy in all birds after 15 seconds of exposure to the electrical current and that the energy of the epilepsy generated depends on the time of exposure to the electric shock. In fact, the tested parameters did not cause epilepsy within 1 second in 100 % of the chickens. In fact an application of the chosen current parameters for up to 12 seconds failed to induce epileptiform EEG in all the birds. 
A minimum exposure time of 15 seconds is needed to result in unconsciousness – there is no evidence that the animals are not subjected to avoidable pain during the stun. 
No
Electrical poultry waterbath stunning parameters 
EFSA Journal 2014;12(7):3745 16 
Table 3: Information provided in the study under slaughterhouse conditions by the submitted study in relation to the onset of unconsciousness and insensibility (3.2.1 of EFSA guidance (EFSA AHAW Panel, 2013a)) 
Study under slaughterhouse conditions 
Information provided 
Is the criterion described/met adequately? 
(yes, no or not possible to assess) 
Start and end of EEG measurement 
In the submitted study it is stated that the same procedure as in the laboratory was followed. 
No 
EEG measurement 
In the submitted study it is stated that the same procedure as in the laboratory was followed. 
A separate Section of the submitted study describes the continued evaluation of the EEG of chickens during bleeding. 
No 
EEG recording analysis 
In the submitted study it is outlined that the EEG analysis considered the drop in power of the 2-30 Hz band in 1 second epochs and the drop in the ratio of the power in the Delta band compared to the other bands before and after stunning. 
Not possible to assess 
EEG results 
In the submitted study data showed an average time of unconsciousness of 32 seconds with a standard deviation of 14 seconds. Such variation in is expected due to individual impedance variations which influence the current that the bird receives while immersed in the waterbath. The distribution of the time of chicken unconsciousness following stunning is shown in Figure 7. 
Results of continued evaluation of the EEG of chickens during bleeding show that the EEG of birds bled by a deep ventral cut (2T) after stunning in Figure 11. 
The EEG at the moment of the cut is also marked by epileptic forms. Following cutting, the amplitude of the EEG drops considerably. After 35 seconds, the bird's EEG reaches a very low amplitude value, providing evidence of death. 
In the submitted study, Figure 12 reports the distribution of time between stunning and death. 
No 
ABM to detect onset of unconsciousness 
In the submitted study resumption of rhythmic breathing as a sign of return of consciousness. A paragraph about physical signs of unconsciousness after stunning is reported in Figure 9. Evidence of death through observation of dilated pupils, absence of breathing and relaxation of the neck and wings during bleeding was performed. 
No
Electrical poultry waterbath stunning parameters 
EFSA Journal 2014;12(7):3745 17 
Table 4: Information provided by the submitted study in relation to animal based measures (ABM) associated with pain, distress and suffering during the induction of unconsciousness (3.2.1 of EFSA guidance (EFSA AHAW Panel, 2013a)) 
Response type 
Groups of ABM 
Study under laboratory conditions 
Study under slaughterhouse conditions 
Do the ABMs suggest pain, distress and suffering (yes, no or not possible to assess, not appliable) 
Behaviour 
Vocalisation 
Information was not provided 
Information was not provided 
No 
Postures and movements 
Information was not provided 
Information was not provided 
No 
General behaviour 
Information was not provided 
Information was not provided 
No 
Physiological response 
Hormones concentration 
Information was not provided 
Information was not provided 
Not applicable for electrical stunning interventions 
Blood metabolites 
Information was not provided 
Information was not provided 
Not applicable for electrical stunning interventions 
Autonomic responses 
Resumption of rhythmic breathing 
Resumption of rhythmic breathing 
In this context this ABM is not related to absence of pain, only an indicator for recovery of consciousness. 
Neurological response 
Brain activity 
EEG was measured 
EEG was measured 
Not applicable for electrical stunning interventions
Electrical poultry waterbath stunning parameters 
EFSA Journal 2014;12(7):3745 18 
ABBREVIATIONS 
ABM Animal-based measure 
AHAW Panel EFSA Panel on Animal Health and Welfare 
EC European Commission 
EFSA European Food Safety Authority 
ECoG Electrocorticogram 
EEG Electroencephalogram 
r.m.s. root mean square

Weitere ähnliche Inhalte

Ähnlich wie EFSA Opinion on electrical requirements for poultry waterbath stunning equipment

Neuro-Stim System Neurostim FDA K140530 Electro Acupuncture Device
Neuro-Stim System Neurostim FDA K140530 Electro Acupuncture DeviceNeuro-Stim System Neurostim FDA K140530 Electro Acupuncture Device
Neuro-Stim System Neurostim FDA K140530 Electro Acupuncture Devicemcalipo
 
DENTAL ARMAMENTARIUMS AND ITS EFFECT ON CARDIAC ARMAMENTARIUMS AND ITS FUNCTI...
DENTAL ARMAMENTARIUMS AND ITS EFFECT ON CARDIAC ARMAMENTARIUMS AND ITS FUNCTI...DENTAL ARMAMENTARIUMS AND ITS EFFECT ON CARDIAC ARMAMENTARIUMS AND ITS FUNCTI...
DENTAL ARMAMENTARIUMS AND ITS EFFECT ON CARDIAC ARMAMENTARIUMS AND ITS FUNCTI...DrHeena tiwari
 
Photoacoustic technology for biological tissues characterization
Photoacoustic technology for biological tissues characterizationPhotoacoustic technology for biological tissues characterization
Photoacoustic technology for biological tissues characterizationjournalBEEI
 
Wolf G.K. et al.: Mechanical Ventilation Guided by Electrical Impedance Tomog...
Wolf G.K. et al.: Mechanical Ventilation Guided by Electrical Impedance Tomog...Wolf G.K. et al.: Mechanical Ventilation Guided by Electrical Impedance Tomog...
Wolf G.K. et al.: Mechanical Ventilation Guided by Electrical Impedance Tomog...Hauke Sann
 
Irbesarton
Irbesarton Irbesarton
Irbesarton SWATHI82
 
IRJET- Liquid Mixture by using Ultrasonic Interferometer
IRJET- Liquid Mixture by using Ultrasonic InterferometerIRJET- Liquid Mixture by using Ultrasonic Interferometer
IRJET- Liquid Mixture by using Ultrasonic InterferometerIRJET Journal
 
Survey of emf emitted by lab equipments in pharmacy labs of southeast univers...
Survey of emf emitted by lab equipments in pharmacy labs of southeast univers...Survey of emf emitted by lab equipments in pharmacy labs of southeast univers...
Survey of emf emitted by lab equipments in pharmacy labs of southeast univers...eSAT Journals
 
IRJET- Design and Development of E-PEST Battery
IRJET-  	  Design and Development of E-PEST BatteryIRJET-  	  Design and Development of E-PEST Battery
IRJET- Design and Development of E-PEST BatteryIRJET Journal
 
Electricity systems for hospitals
Electricity systems for hospitalsElectricity systems for hospitals
Electricity systems for hospitalsBruno De Wachter
 
IEEE PROJECTS CENTER TAMBARAM/PALLAVARAM/CHROMPET- a zigbee based animal hea...
IEEE PROJECTS CENTER  TAMBARAM/PALLAVARAM/CHROMPET- a zigbee based animal hea...IEEE PROJECTS CENTER  TAMBARAM/PALLAVARAM/CHROMPET- a zigbee based animal hea...
IEEE PROJECTS CENTER TAMBARAM/PALLAVARAM/CHROMPET- a zigbee based animal hea...ASHOKKUMAR RAMAR
 
Pupillometry Through the Eyelids
Pupillometry Through the EyelidsPupillometry Through the Eyelids
Pupillometry Through the EyelidsPetteriTeikariPhD
 
Solar power fed adjustuable speed drive system
Solar power fed adjustuable speed drive systemSolar power fed adjustuable speed drive system
Solar power fed adjustuable speed drive systemeSAT Publishing House
 
05 up dated kiran cahyo
05 up dated kiran cahyo05 up dated kiran cahyo
05 up dated kiran cahyoIAESIJEECS
 
Detailed_Design_Report (final)
Detailed_Design_Report (final)Detailed_Design_Report (final)
Detailed_Design_Report (final)Keith Ming
 
Ariunbolor echoendoscopes
Ariunbolor echoendoscopesAriunbolor echoendoscopes
Ariunbolor echoendoscopesArikachinzo
 
2014 CFTCC Annual Symposium: A New Wearable Diffuse Optical Spectroscopic Ima...
2014 CFTCC Annual Symposium: A New Wearable Diffuse Optical Spectroscopic Ima...2014 CFTCC Annual Symposium: A New Wearable Diffuse Optical Spectroscopic Ima...
2014 CFTCC Annual Symposium: A New Wearable Diffuse Optical Spectroscopic Ima...CFTCC
 

Ähnlich wie EFSA Opinion on electrical requirements for poultry waterbath stunning equipment (20)

Neuro-Stim System Neurostim FDA K140530 Electro Acupuncture Device
Neuro-Stim System Neurostim FDA K140530 Electro Acupuncture DeviceNeuro-Stim System Neurostim FDA K140530 Electro Acupuncture Device
Neuro-Stim System Neurostim FDA K140530 Electro Acupuncture Device
 
AAPM REPORT 229
AAPM REPORT 229AAPM REPORT 229
AAPM REPORT 229
 
DENTAL ARMAMENTARIUMS AND ITS EFFECT ON CARDIAC ARMAMENTARIUMS AND ITS FUNCTI...
DENTAL ARMAMENTARIUMS AND ITS EFFECT ON CARDIAC ARMAMENTARIUMS AND ITS FUNCTI...DENTAL ARMAMENTARIUMS AND ITS EFFECT ON CARDIAC ARMAMENTARIUMS AND ITS FUNCTI...
DENTAL ARMAMENTARIUMS AND ITS EFFECT ON CARDIAC ARMAMENTARIUMS AND ITS FUNCTI...
 
Photoacoustic technology for biological tissues characterization
Photoacoustic technology for biological tissues characterizationPhotoacoustic technology for biological tissues characterization
Photoacoustic technology for biological tissues characterization
 
Wolf G.K. et al.: Mechanical Ventilation Guided by Electrical Impedance Tomog...
Wolf G.K. et al.: Mechanical Ventilation Guided by Electrical Impedance Tomog...Wolf G.K. et al.: Mechanical Ventilation Guided by Electrical Impedance Tomog...
Wolf G.K. et al.: Mechanical Ventilation Guided by Electrical Impedance Tomog...
 
Irbesarton
Irbesarton Irbesarton
Irbesarton
 
IRJET- Liquid Mixture by using Ultrasonic Interferometer
IRJET- Liquid Mixture by using Ultrasonic InterferometerIRJET- Liquid Mixture by using Ultrasonic Interferometer
IRJET- Liquid Mixture by using Ultrasonic Interferometer
 
Survey of emf emitted by lab equipments in pharmacy labs of southeast univers...
Survey of emf emitted by lab equipments in pharmacy labs of southeast univers...Survey of emf emitted by lab equipments in pharmacy labs of southeast univers...
Survey of emf emitted by lab equipments in pharmacy labs of southeast univers...
 
IRJET- Design and Development of E-PEST Battery
IRJET-  	  Design and Development of E-PEST BatteryIRJET-  	  Design and Development of E-PEST Battery
IRJET- Design and Development of E-PEST Battery
 
Electricity systems for hospitals
Electricity systems for hospitalsElectricity systems for hospitals
Electricity systems for hospitals
 
IEEE PROJECTS CENTER TAMBARAM/PALLAVARAM/CHROMPET- a zigbee based animal hea...
IEEE PROJECTS CENTER  TAMBARAM/PALLAVARAM/CHROMPET- a zigbee based animal hea...IEEE PROJECTS CENTER  TAMBARAM/PALLAVARAM/CHROMPET- a zigbee based animal hea...
IEEE PROJECTS CENTER TAMBARAM/PALLAVARAM/CHROMPET- a zigbee based animal hea...
 
PV S2 GOKULRAJ QUALIFICATION OF FTIR.pptx
PV S2 GOKULRAJ QUALIFICATION OF FTIR.pptxPV S2 GOKULRAJ QUALIFICATION OF FTIR.pptx
PV S2 GOKULRAJ QUALIFICATION OF FTIR.pptx
 
6004312 0000 eng_a_w
6004312 0000 eng_a_w6004312 0000 eng_a_w
6004312 0000 eng_a_w
 
Pupillometry Through the Eyelids
Pupillometry Through the EyelidsPupillometry Through the Eyelids
Pupillometry Through the Eyelids
 
Solar power fed adjustuable speed drive system
Solar power fed adjustuable speed drive systemSolar power fed adjustuable speed drive system
Solar power fed adjustuable speed drive system
 
05 up dated kiran cahyo
05 up dated kiran cahyo05 up dated kiran cahyo
05 up dated kiran cahyo
 
Detailed_Design_Report (final)
Detailed_Design_Report (final)Detailed_Design_Report (final)
Detailed_Design_Report (final)
 
Ayurvedic pulse
Ayurvedic pulseAyurvedic pulse
Ayurvedic pulse
 
Ariunbolor echoendoscopes
Ariunbolor echoendoscopesAriunbolor echoendoscopes
Ariunbolor echoendoscopes
 
2014 CFTCC Annual Symposium: A New Wearable Diffuse Optical Spectroscopic Ima...
2014 CFTCC Annual Symposium: A New Wearable Diffuse Optical Spectroscopic Ima...2014 CFTCC Annual Symposium: A New Wearable Diffuse Optical Spectroscopic Ima...
2014 CFTCC Annual Symposium: A New Wearable Diffuse Optical Spectroscopic Ima...
 

Mehr von Harm Kiezebrink

Applying Firefighting Foam for Depopulation.pdf
Applying Firefighting Foam for Depopulation.pdfApplying Firefighting Foam for Depopulation.pdf
Applying Firefighting Foam for Depopulation.pdfHarm Kiezebrink
 
World bank evaluating the economic consequences of avian influenza
World bank evaluating the economic consequences of avian influenzaWorld bank evaluating the economic consequences of avian influenza
World bank evaluating the economic consequences of avian influenzaHarm Kiezebrink
 
Gas alternatives to carbon dioxide for euthanasia a piglet perspective
Gas alternatives to carbon dioxide for euthanasia  a piglet perspectiveGas alternatives to carbon dioxide for euthanasia  a piglet perspective
Gas alternatives to carbon dioxide for euthanasia a piglet perspectiveHarm Kiezebrink
 
Anoxia - applying the technique
Anoxia - applying the techniqueAnoxia - applying the technique
Anoxia - applying the techniqueHarm Kiezebrink
 
Animal Euthanasia: What are the challenges?
Animal Euthanasia: What are the challenges?Animal Euthanasia: What are the challenges?
Animal Euthanasia: What are the challenges?Harm Kiezebrink
 
WHO warns of H7 N9 pandemic
WHO warns of H7 N9 pandemic WHO warns of H7 N9 pandemic
WHO warns of H7 N9 pandemic Harm Kiezebrink
 
Laves presentation practical experiences in the culling of poultry in germany
Laves presentation practical experiences in the culling of poultry in germanyLaves presentation practical experiences in the culling of poultry in germany
Laves presentation practical experiences in the culling of poultry in germanyHarm Kiezebrink
 
Berg et al. 2014 killing of spent laying hens using co2 in poultry barns
Berg et al. 2014 killing of spent laying hens using co2 in poultry barnsBerg et al. 2014 killing of spent laying hens using co2 in poultry barns
Berg et al. 2014 killing of spent laying hens using co2 in poultry barnsHarm Kiezebrink
 
Neutralizing risks instead of stamping-out
Neutralizing risks instead of stamping-outNeutralizing risks instead of stamping-out
Neutralizing risks instead of stamping-outHarm Kiezebrink
 
Ventilation Shutdown: who takes the responsibility to flip the switch?
Ventilation Shutdown: who takes the responsibility to flip the switch?Ventilation Shutdown: who takes the responsibility to flip the switch?
Ventilation Shutdown: who takes the responsibility to flip the switch?Harm Kiezebrink
 
Stamping out strategy failed
Stamping out strategy failedStamping out strategy failed
Stamping out strategy failedHarm Kiezebrink
 
FLI Seminar on different response strategies: Stamping out or Neutralization
FLI Seminar on different response strategies: Stamping out or NeutralizationFLI Seminar on different response strategies: Stamping out or Neutralization
FLI Seminar on different response strategies: Stamping out or NeutralizationHarm Kiezebrink
 
Spatial, temporal and genetic dynamics of H5N1 in china
Spatial, temporal and genetic dynamics of H5N1 in chinaSpatial, temporal and genetic dynamics of H5N1 in china
Spatial, temporal and genetic dynamics of H5N1 in chinaHarm Kiezebrink
 
Different environmental drivers of H5N1 outbreaks in poultry and wild birds
Different environmental drivers of H5N1 outbreaks in poultry and wild birdsDifferent environmental drivers of H5N1 outbreaks in poultry and wild birds
Different environmental drivers of H5N1 outbreaks in poultry and wild birdsHarm Kiezebrink
 
H5N8 virus dutch outbreak (2014) linked to sequences of strains from asia
H5N8 virus dutch outbreak (2014) linked to sequences of strains from asiaH5N8 virus dutch outbreak (2014) linked to sequences of strains from asia
H5N8 virus dutch outbreak (2014) linked to sequences of strains from asiaHarm Kiezebrink
 
Wind mediated spread of LPAI
Wind mediated spread of LPAIWind mediated spread of LPAI
Wind mediated spread of LPAIHarm Kiezebrink
 
Per contact probability of infection by Highly Pathogenic Avian Influenza
Per contact probability of infection by Highly Pathogenic Avian InfluenzaPer contact probability of infection by Highly Pathogenic Avian Influenza
Per contact probability of infection by Highly Pathogenic Avian InfluenzaHarm Kiezebrink
 
Supplementary information wind mediated transmission HPAI
Supplementary information wind mediated transmission HPAISupplementary information wind mediated transmission HPAI
Supplementary information wind mediated transmission HPAIHarm Kiezebrink
 
Avian Influenza in the Netherlands 2003: comparing culling methods
Avian Influenza in the Netherlands 2003: comparing culling methodsAvian Influenza in the Netherlands 2003: comparing culling methods
Avian Influenza in the Netherlands 2003: comparing culling methodsHarm Kiezebrink
 

Mehr von Harm Kiezebrink (20)

Applying Firefighting Foam for Depopulation.pdf
Applying Firefighting Foam for Depopulation.pdfApplying Firefighting Foam for Depopulation.pdf
Applying Firefighting Foam for Depopulation.pdf
 
World bank evaluating the economic consequences of avian influenza
World bank evaluating the economic consequences of avian influenzaWorld bank evaluating the economic consequences of avian influenza
World bank evaluating the economic consequences of avian influenza
 
Gas alternatives to carbon dioxide for euthanasia a piglet perspective
Gas alternatives to carbon dioxide for euthanasia  a piglet perspectiveGas alternatives to carbon dioxide for euthanasia  a piglet perspective
Gas alternatives to carbon dioxide for euthanasia a piglet perspective
 
Anoxia - applying the technique
Anoxia - applying the techniqueAnoxia - applying the technique
Anoxia - applying the technique
 
Animal Euthanasia: What are the challenges?
Animal Euthanasia: What are the challenges?Animal Euthanasia: What are the challenges?
Animal Euthanasia: What are the challenges?
 
Anoxia: what is it?
Anoxia:   what is it?Anoxia:   what is it?
Anoxia: what is it?
 
WHO warns of H7 N9 pandemic
WHO warns of H7 N9 pandemic WHO warns of H7 N9 pandemic
WHO warns of H7 N9 pandemic
 
Laves presentation practical experiences in the culling of poultry in germany
Laves presentation practical experiences in the culling of poultry in germanyLaves presentation practical experiences in the culling of poultry in germany
Laves presentation practical experiences in the culling of poultry in germany
 
Berg et al. 2014 killing of spent laying hens using co2 in poultry barns
Berg et al. 2014 killing of spent laying hens using co2 in poultry barnsBerg et al. 2014 killing of spent laying hens using co2 in poultry barns
Berg et al. 2014 killing of spent laying hens using co2 in poultry barns
 
Neutralizing risks instead of stamping-out
Neutralizing risks instead of stamping-outNeutralizing risks instead of stamping-out
Neutralizing risks instead of stamping-out
 
Ventilation Shutdown: who takes the responsibility to flip the switch?
Ventilation Shutdown: who takes the responsibility to flip the switch?Ventilation Shutdown: who takes the responsibility to flip the switch?
Ventilation Shutdown: who takes the responsibility to flip the switch?
 
Stamping out strategy failed
Stamping out strategy failedStamping out strategy failed
Stamping out strategy failed
 
FLI Seminar on different response strategies: Stamping out or Neutralization
FLI Seminar on different response strategies: Stamping out or NeutralizationFLI Seminar on different response strategies: Stamping out or Neutralization
FLI Seminar on different response strategies: Stamping out or Neutralization
 
Spatial, temporal and genetic dynamics of H5N1 in china
Spatial, temporal and genetic dynamics of H5N1 in chinaSpatial, temporal and genetic dynamics of H5N1 in china
Spatial, temporal and genetic dynamics of H5N1 in china
 
Different environmental drivers of H5N1 outbreaks in poultry and wild birds
Different environmental drivers of H5N1 outbreaks in poultry and wild birdsDifferent environmental drivers of H5N1 outbreaks in poultry and wild birds
Different environmental drivers of H5N1 outbreaks in poultry and wild birds
 
H5N8 virus dutch outbreak (2014) linked to sequences of strains from asia
H5N8 virus dutch outbreak (2014) linked to sequences of strains from asiaH5N8 virus dutch outbreak (2014) linked to sequences of strains from asia
H5N8 virus dutch outbreak (2014) linked to sequences of strains from asia
 
Wind mediated spread of LPAI
Wind mediated spread of LPAIWind mediated spread of LPAI
Wind mediated spread of LPAI
 
Per contact probability of infection by Highly Pathogenic Avian Influenza
Per contact probability of infection by Highly Pathogenic Avian InfluenzaPer contact probability of infection by Highly Pathogenic Avian Influenza
Per contact probability of infection by Highly Pathogenic Avian Influenza
 
Supplementary information wind mediated transmission HPAI
Supplementary information wind mediated transmission HPAISupplementary information wind mediated transmission HPAI
Supplementary information wind mediated transmission HPAI
 
Avian Influenza in the Netherlands 2003: comparing culling methods
Avian Influenza in the Netherlands 2003: comparing culling methodsAvian Influenza in the Netherlands 2003: comparing culling methods
Avian Influenza in the Netherlands 2003: comparing culling methods
 

Kürzlich hochgeladen

Botany 4th semester series (krishna).pdf
Botany 4th semester series (krishna).pdfBotany 4th semester series (krishna).pdf
Botany 4th semester series (krishna).pdfSumit Kumar yadav
 
VIRUSES structure and classification ppt by Dr.Prince C P
VIRUSES structure and classification ppt by Dr.Prince C PVIRUSES structure and classification ppt by Dr.Prince C P
VIRUSES structure and classification ppt by Dr.Prince C PPRINCE C P
 
Biological Classification BioHack (3).pdf
Biological Classification BioHack (3).pdfBiological Classification BioHack (3).pdf
Biological Classification BioHack (3).pdfmuntazimhurra
 
All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...
All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...
All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...Sérgio Sacani
 
Recombinant DNA technology (Immunological screening)
Recombinant DNA technology (Immunological screening)Recombinant DNA technology (Immunological screening)
Recombinant DNA technology (Immunological screening)PraveenaKalaiselvan1
 
Presentation Vikram Lander by Vedansh Gupta.pptx
Presentation Vikram Lander by Vedansh Gupta.pptxPresentation Vikram Lander by Vedansh Gupta.pptx
Presentation Vikram Lander by Vedansh Gupta.pptxgindu3009
 
Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...
Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...
Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...Sérgio Sacani
 
Nightside clouds and disequilibrium chemistry on the hot Jupiter WASP-43b
Nightside clouds and disequilibrium chemistry on the hot Jupiter WASP-43bNightside clouds and disequilibrium chemistry on the hot Jupiter WASP-43b
Nightside clouds and disequilibrium chemistry on the hot Jupiter WASP-43bSérgio Sacani
 
Raman spectroscopy.pptx M Pharm, M Sc, Advanced Spectral Analysis
Raman spectroscopy.pptx M Pharm, M Sc, Advanced Spectral AnalysisRaman spectroscopy.pptx M Pharm, M Sc, Advanced Spectral Analysis
Raman spectroscopy.pptx M Pharm, M Sc, Advanced Spectral AnalysisDiwakar Mishra
 
GBSN - Microbiology (Unit 1)
GBSN - Microbiology (Unit 1)GBSN - Microbiology (Unit 1)
GBSN - Microbiology (Unit 1)Areesha Ahmad
 
fundamental of entomology all in one topics of entomology
fundamental of entomology all in one topics of entomologyfundamental of entomology all in one topics of entomology
fundamental of entomology all in one topics of entomologyDrAnita Sharma
 
Unlocking the Potential: Deep dive into ocean of Ceramic Magnets.pptx
Unlocking  the Potential: Deep dive into ocean of Ceramic Magnets.pptxUnlocking  the Potential: Deep dive into ocean of Ceramic Magnets.pptx
Unlocking the Potential: Deep dive into ocean of Ceramic Magnets.pptxanandsmhk
 
Pests of cotton_Sucking_Pests_Dr.UPR.pdf
Pests of cotton_Sucking_Pests_Dr.UPR.pdfPests of cotton_Sucking_Pests_Dr.UPR.pdf
Pests of cotton_Sucking_Pests_Dr.UPR.pdfPirithiRaju
 
Physiochemical properties of nanomaterials and its nanotoxicity.pptx
Physiochemical properties of nanomaterials and its nanotoxicity.pptxPhysiochemical properties of nanomaterials and its nanotoxicity.pptx
Physiochemical properties of nanomaterials and its nanotoxicity.pptxAArockiyaNisha
 
GBSN - Biochemistry (Unit 1)
GBSN - Biochemistry (Unit 1)GBSN - Biochemistry (Unit 1)
GBSN - Biochemistry (Unit 1)Areesha Ahmad
 
Recombination DNA Technology (Nucleic Acid Hybridization )
Recombination DNA Technology (Nucleic Acid Hybridization )Recombination DNA Technology (Nucleic Acid Hybridization )
Recombination DNA Technology (Nucleic Acid Hybridization )aarthirajkumar25
 
Lucknow 💋 Russian Call Girls Lucknow Finest Escorts Service 8923113531 Availa...
Lucknow 💋 Russian Call Girls Lucknow Finest Escorts Service 8923113531 Availa...Lucknow 💋 Russian Call Girls Lucknow Finest Escorts Service 8923113531 Availa...
Lucknow 💋 Russian Call Girls Lucknow Finest Escorts Service 8923113531 Availa...anilsa9823
 
Pests of mustard_Identification_Management_Dr.UPR.pdf
Pests of mustard_Identification_Management_Dr.UPR.pdfPests of mustard_Identification_Management_Dr.UPR.pdf
Pests of mustard_Identification_Management_Dr.UPR.pdfPirithiRaju
 
DIFFERENCE IN BACK CROSS AND TEST CROSS
DIFFERENCE IN  BACK CROSS AND TEST CROSSDIFFERENCE IN  BACK CROSS AND TEST CROSS
DIFFERENCE IN BACK CROSS AND TEST CROSSLeenakshiTyagi
 

Kürzlich hochgeladen (20)

Botany 4th semester series (krishna).pdf
Botany 4th semester series (krishna).pdfBotany 4th semester series (krishna).pdf
Botany 4th semester series (krishna).pdf
 
VIRUSES structure and classification ppt by Dr.Prince C P
VIRUSES structure and classification ppt by Dr.Prince C PVIRUSES structure and classification ppt by Dr.Prince C P
VIRUSES structure and classification ppt by Dr.Prince C P
 
Biological Classification BioHack (3).pdf
Biological Classification BioHack (3).pdfBiological Classification BioHack (3).pdf
Biological Classification BioHack (3).pdf
 
All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...
All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...
All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...
 
Recombinant DNA technology (Immunological screening)
Recombinant DNA technology (Immunological screening)Recombinant DNA technology (Immunological screening)
Recombinant DNA technology (Immunological screening)
 
Presentation Vikram Lander by Vedansh Gupta.pptx
Presentation Vikram Lander by Vedansh Gupta.pptxPresentation Vikram Lander by Vedansh Gupta.pptx
Presentation Vikram Lander by Vedansh Gupta.pptx
 
Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...
Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...
Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...
 
Nightside clouds and disequilibrium chemistry on the hot Jupiter WASP-43b
Nightside clouds and disequilibrium chemistry on the hot Jupiter WASP-43bNightside clouds and disequilibrium chemistry on the hot Jupiter WASP-43b
Nightside clouds and disequilibrium chemistry on the hot Jupiter WASP-43b
 
Raman spectroscopy.pptx M Pharm, M Sc, Advanced Spectral Analysis
Raman spectroscopy.pptx M Pharm, M Sc, Advanced Spectral AnalysisRaman spectroscopy.pptx M Pharm, M Sc, Advanced Spectral Analysis
Raman spectroscopy.pptx M Pharm, M Sc, Advanced Spectral Analysis
 
GBSN - Microbiology (Unit 1)
GBSN - Microbiology (Unit 1)GBSN - Microbiology (Unit 1)
GBSN - Microbiology (Unit 1)
 
fundamental of entomology all in one topics of entomology
fundamental of entomology all in one topics of entomologyfundamental of entomology all in one topics of entomology
fundamental of entomology all in one topics of entomology
 
Unlocking the Potential: Deep dive into ocean of Ceramic Magnets.pptx
Unlocking  the Potential: Deep dive into ocean of Ceramic Magnets.pptxUnlocking  the Potential: Deep dive into ocean of Ceramic Magnets.pptx
Unlocking the Potential: Deep dive into ocean of Ceramic Magnets.pptx
 
Pests of cotton_Sucking_Pests_Dr.UPR.pdf
Pests of cotton_Sucking_Pests_Dr.UPR.pdfPests of cotton_Sucking_Pests_Dr.UPR.pdf
Pests of cotton_Sucking_Pests_Dr.UPR.pdf
 
Physiochemical properties of nanomaterials and its nanotoxicity.pptx
Physiochemical properties of nanomaterials and its nanotoxicity.pptxPhysiochemical properties of nanomaterials and its nanotoxicity.pptx
Physiochemical properties of nanomaterials and its nanotoxicity.pptx
 
GBSN - Biochemistry (Unit 1)
GBSN - Biochemistry (Unit 1)GBSN - Biochemistry (Unit 1)
GBSN - Biochemistry (Unit 1)
 
Recombination DNA Technology (Nucleic Acid Hybridization )
Recombination DNA Technology (Nucleic Acid Hybridization )Recombination DNA Technology (Nucleic Acid Hybridization )
Recombination DNA Technology (Nucleic Acid Hybridization )
 
Lucknow 💋 Russian Call Girls Lucknow Finest Escorts Service 8923113531 Availa...
Lucknow 💋 Russian Call Girls Lucknow Finest Escorts Service 8923113531 Availa...Lucknow 💋 Russian Call Girls Lucknow Finest Escorts Service 8923113531 Availa...
Lucknow 💋 Russian Call Girls Lucknow Finest Escorts Service 8923113531 Availa...
 
Pests of mustard_Identification_Management_Dr.UPR.pdf
Pests of mustard_Identification_Management_Dr.UPR.pdfPests of mustard_Identification_Management_Dr.UPR.pdf
Pests of mustard_Identification_Management_Dr.UPR.pdf
 
DIFFERENCE IN BACK CROSS AND TEST CROSS
DIFFERENCE IN  BACK CROSS AND TEST CROSSDIFFERENCE IN  BACK CROSS AND TEST CROSS
DIFFERENCE IN BACK CROSS AND TEST CROSS
 
CELL -Structural and Functional unit of life.pdf
CELL -Structural and Functional unit of life.pdfCELL -Structural and Functional unit of life.pdf
CELL -Structural and Functional unit of life.pdf
 

EFSA Opinion on electrical requirements for poultry waterbath stunning equipment

  • 1. EFSA Journal 2014;12(7):3745 Suggested citation: EFSA AHAW Panel (Animal Health and Welfare), 2014. Scientific Opinion on electrical requirements for poultry waterbath stunning equipment. EFSA Journal 2014;12(7):3745, 18 pp. doi:10.2903/j.efsa.2014.3745 Available online: www.efsa.europa.eu/efsajournal © European Food Safety Authority, 2014 SCIENTIFIC OPINION Scientific Opinion on electrical requirements for poultry waterbath stunning equipment1 EFSA Panel on Animal Health and Welfare (AHAW)2, 3 European Food Safety Authority (EFSA), Parma, Italy ABSTRACT The European Commission (EC) requested that the EFSA Panel on Animal Health and Welfare (AHAW Panel) delivers a scientific opinion on a study that proposes parameters for poultry electrical waterbath stunning different to those laid down in Council Regulation (EC) No 1099/2009 on the protection of animals at the time of killing. The submitted study reports upon the use (mean + SD) of a current of 104.00 ± 3.88 mA, a voltage of 125.86 ± 3.28 V and a frequency of 589.78 ± 0.63 Hz using a square wave in alternating current (AC) with a 50 % duty cycle. These conditions were applied for 15 seconds to chickens under laboratory and slaughterhouse conditions. The submitted study was peer-reviewed by the AHAW Panel in the manner detailed in its ‘Guidance on the assessment criteria for studies evaluating the effectiveness of stunning intervention regarding animal protection at the time of killing’. The methodology and the data reported do not provide conclusive evidence that the combination of the proposed electrical frequency and current induced unconsciousness without exposing the chickens to avoidable pain and suffering. Further, some chickens did not remain unconscious for a sufficient time to prevent avoidable pain and suffering during slaughter. Because the information provided in the study was incomplete and insufficient, it did not pass the eligibility phase of the assessment. In the context of Directive 2010/63/EU on the protection of animals used for scientific purposes, and current scientific evidence, a frequency of 600 Hz with a current of 104 mA does not result in efficient stunning of poultry. Therefore, additional research into these stunning parameters is not recommended. © European Food Safety Authority, 2014 KEY WORDS poultry, waterbath, electric, stunning, parameter, welfare, EEG 1 On request from European Commission, Question No EFSA-Q-2014-00089, adopted on 25 June 2014. 2 Panel members: Edith Authie, Charlotte Berg, Anette Bøtner, Howard Browman, Ilaria Capua, Aline De Koeijer, Klaus Depner, Mariano Domingo, Sandra Edwards, Christine Fourichon, Frank Koenen, Simon More, Mohan Raj, Liisa Sihvonen, Hans Spoolder, Jan Arend Stegeman, Hans-Hermann Thulke, Ivar Vågsholm, Antonio Velarde, Preben Willeberg and Stéphan Zientara. Correspondence: ALPHA@efsa.europa.eu 3 Acknowledgement: The Panel wishes to thank the members of the Working Group on electrical requirements for poultry waterbath stunning equipment: Howard Browman, Mohan Raj and Antonio Velarde for the preparatory work on this scientific opinion and EFSA staff: Renata Leuschner and Denise Candiani for the support provided to this scientific opinion.
  • 2. Electrical poultry waterbath stunning parameters EFSA Journal 2014;12(7):3745 2 SUMMARY Following a request from the European Commission, the EFSA Panel on Animal Health and Welfare (AHAW) was asked to deliver a scientific opinion on electrical requirements for waterbath stunning equipment. The AHAW Panel addressed the terms of reference (ToRs) as provided by the European Commission, based upon information received from a third country. The Commission requested the EFSA to review the scientific publication provided and to assess to what extent the electrical parameters proposed for stunning poultry are able to provide a level of animal welfare at least equivalent to that ensured by the currently allowed methods and, in case of favourable reply, under what conditions. Following review of the provided information and evaluating the stunning procedure applied and its welfare outcome (ToR1) it was concluded that the submitted study does not provide enough scientific information upon which to base an assessment of the scientific approach and parameters suggested. Consequently, a full assessment of the animal welfare implications of the proposed stunning procedure was not undertaken (ToR2) and a revision of the electrical requirements for waterbath stunning equipment laid down in Table 2 of Chapter II of Annex I to Council Regulation (EC) No 1099/2009 is not recommended (ToR3). Nonetheless, the information provided was sufficient to conclude that the birds were not rendered immediately unconscious by the intervention. Application of a current less than that required to induce immediate unconsciousness causes pain, distress and suffering. The study failed to demonstrate absence of pain and suffering until onset of unconsciousness. The minimum duration of unconsciousness was too short to ensure unconsciousness until death by bleeding. In multiple birds waterbath stunning situations, such as the one assessed here, the electrical resistance varies widely between birds making it impossible to deliver the same constant and predetermined current to each individual bird. The complexity of such multiple bird electrical waterbath stunning systems used in poultry slaughterhouses is not conducive to maintaining good animal welfare and, therefore, alternatives should be developed/implemented. Studies such as the one assessed here should consider the internationally accepted basic principle referred to as the 3 Rs (replacement, reduction and refinement, according to Directive 2010/63/EU), which recommend approaches to minimize the use of animals for experimental purposes in line with the European Regulation on protection of animals used for scientific purposes.
  • 3. Electrical poultry waterbath stunning parameters EFSA Journal 2014;12(7):3745 3 TABLE OF CONTENTS Abstract .................................................................................................................................................... 1 Summary .................................................................................................................................................. 2 Table of contents ...................................................................................................................................... 3 Background as provided by the European Commission ........................................................................... 4 Terms of reference as provided by European Commission ...................................................................... 4 Assessment ............................................................................................................................................... 5 1. Introduction ..................................................................................................................................... 5 2. Documentation provided to EFSA ................................................................................................... 5 3. Assessment approach ....................................................................................................................... 6 4. Assessment of eligibility criteria ..................................................................................................... 6 4.1. Intervention of study one ........................................................................................................ 6 4.2. Outcome of study one ............................................................................................................. 7 4.2.1. Onset of unconsciousness and insensibility ........................................................................ 7 4.2.2. Study under controlled laboratory conditions ..................................................................... 7 4.2.2.1. Conclusion ................................................................................................................. 8 4.2.3. Study under slaughterhouse conditions .............................................................................. 8 4.2.3.1. Conclusion ................................................................................................................. 9 4.2.4. Absence of pain, distress and suffering until the loss of consciousness and sensibility ..... 9 4.2.4.1. Conclusion ................................................................................................................. 9 4.2.5. Duration of unconsciousness and insensibility ................................................................... 9 4.2.5.1. Conclusion ............................................................................................................... 10 4.3. Assessment of study two providing details on measurement of the electric current that flows into the bird brain ............................................................................................................................... 10 5. Reporting quality ........................................................................................................................... 10 5.1. Assessment of the reporting quality of the submitted studies based on the selected parameters .......................................................................................................................................... 10 6. Methodological quality .................................................................................................................. 10 6.1. Quality assessment of the internal validity of the submitted studies .................................... 10 Conclusions and recommendations ........................................................................................................ 10 References .............................................................................................................................................. 11 Appendix ................................................................................................................................................ 13 Abbreviations ......................................................................................................................................... 18
  • 4. Electrical poultry waterbath stunning parameters EFSA Journal 2014;12(7):3745 4 BACKGROUND AS PROVIDED BY THE EUROPEAN COMMISSION Table 2 of Chapter II of Annex I to Council Regulation (EC) No 1099/20094 on the protection of animals at the time of killing sets out the average values per animal of electrical requirement which must be used when stunning chickens, turkeys, ducks, geese and quails using waterbath stunning equipment. These requirements are based on two previous EFSA opinions on the subject adopted respectively in 2004 and 2006 (EFSA, 2004, 2006). In the meantime the EFSA issued another opinion on the issue in 2012 (EFSA AHAW Panel, 2012). Article 2 (f) of Council Regulation (EC) No 1099/20094 defines ‘stunning’ as ‘any intentionally induced process which causes loss of consciousness and sensibility without pain including any process resulting in instantaneous death’. Furthermore, Article 4 states that ‘The loss of consciousness and sensibility should be maintained until the death of the animal’. Article 4 (2) of the same Regulation4 allows the Commission to amend its Annex I so as to take into account scientific and technical progress on the basis of an opinion of the EFSA. Any such amendments shall ensure a level of animal welfare at least equivalent to that ensured by the existing methods. The Commission has received information from a third country which may justify amending these parameters (submitted study). In order to reply to this request, the Commission would like to request the EFSA to review the scientific publication provided and assess to which extent the electrical parameters proposed for stunning poultry are able to provide a level of animal welfare at least equivalent to that ensured by the currently allowed methods and, in case of favourable reply, under which conditions. TERMS OF REFERENCE AS PROVIDED BY EUROPEAN COMMISSION The Commission therefore considers it opportune to request the EFSA to give an independent view on the electrical requirements for stunning equipment applicable for poultry. Review if the study provides sufficient scientific details as to evaluate the stunning procedure applied and its welfare outcome; In case of favourable reply, carry out a full welfare assessment of the animal welfare implications of the proposed stunning procedure, taking into account other relevant scientific references; Recommend, if necessary, a revision of the electrical requirements applicable for waterbath stunning equipment laid down in Table 2 of Chapter II of Annex I to Council Regulation (EC) No 1099/20094. 4 Council Regulation (EC) No 1099/2009 of 24 September 2009 on the protection of animals at the time of killing. OJ L 303, 18.11.2009, p. 1-30.
  • 5. Electrical poultry waterbath stunning parameters EFSA Journal 2014;12(7):3745 5 ASSESSMENT 1. Introduction Electrical waterbath stunning is permitted for use in poultry when the technical criteria described in Annex I of Council Regulation (EC) No 1099/20094 are fulfilled. The legislative requirements prescribe that the brain should be exposed to a current generating generalised epileptiform activity in the EEG and possibly fibrillation or stopping of the heart. For stunning interventions that do not induce immediate unconsciousness, the alternative procedure should ensure 1) absence of pain, distress and suffering until the onset of unconsciousness, and 2) that the animal remains unconscious and insensible until death. A study researching modified electrical parameters of waterbath stunning should record the intervention applied to individual animals. The legislation states that the key parameters are minimum current, minimum voltage, maximum frequency, frequency of calibration of the equipment, prevention of electrical shocks before stunning, minimising pain at shackling, optimisation of the current flow, maximum shackle duration before the waterbath, minimum time of exposure for each animal, immersion of the birds up to the base of the wings and maximum stun-to-stick/kill interval(s) for frequency(ies) over 50 Hz. Studies analysing a modification of a currently permitted method need to describe all of the key legal parameters. Some parameters are divided into several detailed components - as specified in the Guidance document (EFSA AHAW Panel, 2013a) - to ensure a comprehensive description of the applied stunning intervention (Table 1 in the Appendix). In addition, the throughput rate should be specified where appropriate (e.g. field studies). EFSA herein presents an opinion on the study received for a scientific evaluation entitled ‘Study of chicken stunning using electroencephalogram’ in a manner consistent with the terms of reference provided by the European Commission. EFSA assessed only the stunning procedure itself and did not take into account any pre-stunning phases. A full assessment of the welfare implications, which would need to take into account both pre-stunning and stunning phases of the slaughter process, is beyond the scope of this mandate. 2. Documentation provided to EFSA The Commission has received information from a third country entitled ‘Study of chicken stunning using electroencephalogram’ in February 2014. This study5 was sent to EFSA for a scientific evaluation and comprises an introduction (part 1), materials and methods (part 2) for two studies entitled in the document ‘study 1’ and ‘study 2’, results (part 3) for the two studies, a conclusion (part 4), a table entitled key parameters and related specifications (part 5) and a reference Section with literature (part 6): STUDY 1 – Composed of the Sections entitled ‘Evaluations of the stun without sticking’ comprised of the sub-sections ‘test carried out on laboratory’, ‘test carried out on slaughterhouse’; followed by a Section ‘continuous evaluation of EEG of chickens during bleeding’ STUDY 2 – Provides details on measurement of the electric current that flows into the bird brain. 5 by Ernane José Xavier da Costa1; Sulivan Pereira Alves2; Paulo Sergio Rosa3; Gerson Scheuermann4; Arlei Coldebella5; Leonardo Thielo de La Vega6; Luis Teixeira7 [1PhD. Professor. University of São Paulo, USP; 2D.Sc. Technical Coordinator, União Brasileira de Avicultura; 3D.Sc. Researcher; EMBRAPA Swine and Poultry; 4PhD. Researcher - EMBRAPA Swine and Poultry; 5Dsc. Researcher, EMBRAPA Swine and Poultry; 6Bachelor Veterinary Medicine, Quality Planning, Brasil Foods/BRF; 7Bachelor Veterinary Medicine, Federal Agriculture and Livestock Inspector, Permanent Technical Commission of Animal Well-Being, CTBEA/MAPA]
  • 6. Electrical poultry waterbath stunning parameters EFSA Journal 2014;12(7):3745 6 3. Assessment approach The assessment of the submitted studies was carried out in a manner analogous to that described in the guidance document (EFSA AHAW Panel, 2013a). The assessment was first conducted independently by each working group (WG) member. The individual assessments were then discussed to reach a consensus on issues over which the experts had expressed different opinions. The assessment focuses initially on term of reference one (ToR1). Each of the three WG experts independently reviewed if the eligibility criteria set out in the guidance for electrical waterbath stunning (EFSA AHAW Panel, 2013a) were met by the study. Since the submitted study did not meet the eligibility criteria, neither a full assessment of the animal welfare implications of the proposed alternative stunning intervention (ToR2), nor a systematic review of the electrical requirements applicable for waterbath stunning equipment (ToR3) were undertaken. 4. Assessment of eligibility criteria 4.1. Intervention of study one The information provided in the submitted study was assessed following the procedure detailed in the EFSA guidance (EFSA AHAW Panel, 2013a). A detailed evaluation of the reported parameters in the submitted study is presented in Table 1 (Appendix). The basis for the conclusions drawn by the AHAW Panel is summarised below. Only those aspects that were not considered adequate are commented upon. Importantly, the Table presented in Section 5 of the submitted study does not specify whether the information provided is related to the laboratory study, the study under slaughterhouse conditions, or both. Nor is this Table referred to in the body of the text. As a result, it was impossible to assess the information presented in Section 5. Therefore, the assessment below, and in the Tables in the Appendix, was restricted to information that was supported by descriptive text in the body of the manuscript. The parameters of the intervention were presented in an inconsistent and contradictory manner. It was not possible to unequivocally determine which intervention parameters were applied when and where during the study. Key parameters (see Table 4, Section 3.1.2.2 of the EFSA guidance (EFSA AHAW Panel, 2013a)) were not described adequately - for example, calibration of the equipment, optimisation of the current flow, information on the concentration and type of salt used in the waterbath (chemical formula), information on the cleanliness of chickens, etc. The electrical stunning equipment is not adequately described. For example, it is not clear whether a constant voltage source was used to stun broilers individually and how this minimum voltage was set to deliver the minimum current to birds. In the manuscript, it is mentioned (Section 2.1.1.1) that the electrical parameters were verified using a hand-held digital multimeter (usually called ‘Galinha Electrônica’) made by Fluxo® - however, neither the manner in which this was done, nor the results of the measurements, are provided. Information provided in the submitted manuscript regarding the maximum stun-to-stick/kill interval(s) for frequency over 50 Hz was insufficient regarding the duration of unconsciousness. The minimum duration of unconsciousness induced by stunning should be longer than the sum of time interval between the end of stunning and neck cutting and the time it takes for death to occur due to blood loss. The authors state that the same procedures were followed in the slaughterhouse as in the laboratory (Section 2.1.1.2). However, besides this statement, no further description was provided, making it impossible to assess the slaughterhouse study.
  • 7. Electrical poultry waterbath stunning parameters EFSA Journal 2014;12(7):3745 7 4.2. Outcome of study one 4.2.1. Onset of unconsciousness and insensibility Research studies evaluating stunning methods require well controlled experiments under laboratory conditions as a first step to characterise the animals’ responses (unconsciousness, absence of pain if the induction of unconsciousness is not immediate) using the most sensitive and specific methods available (e.g. behaviour, EEG, physiological response) and to establish the correlations between these measurements and non-invasive animal-based parameters that can be applied in slaughterhouses (EFSA AHAW Panel, 2013a). Alternative stunning methods or parameters should disrupt the neuronal function and, thereby, render animals unconscious and insensible. The extent of disruption caused by a stunning intervention, and the induction of unconsciousness and insensibility, are best demonstrated using EEGs and ECoGs (EFSA, 2004, 2013; EFSA AHAW Panel, 2013a,b,c). As described in the EFSA guidance (EFSA AHAW Panel, 2013a), it is acceptable that studies reporting interventions assess the onset of unconsciousness as this state is always accompanied by the onset of insensibility. In studies under laboratory conditions, unconsciousness and insensibility can be determined by the following EEG patterns: induction of a generalised epileptiform activity in the brain, which can be recognised from the predominance of 8-13 Hz high-amplitude EEG activity in mammals and possibly slightly lower frequency in poultry which should be followed by a quiescent EEG, or an immediate onset of a quiescent EEG, or abolition of visual or auditory evoked responses or potentials in the brain immediately after the stunning. 4.2.2. Study under controlled laboratory conditions The information provided in the submitted study was assessed following the procedure detailed in the EFSA guidance (EFSA AHAW Panel, 2013a). A detailed evaluation of the reported parameters in the submitted study is presented in Table 2 (Appendix). The basis for the conclusions drawn by the AHAW Panel is summarised below. Only those aspects that were not considered adequate are commented upon. EEG recording and analysis – The results are inconsistent with the methodology described in the method Section. It is stated in the method Section that the EEG signals were analysed and filtered into four frequency bands but data relevant to only one of the frequency (delta) band is reported in the results Section, although no conclusions about the predominance of delta bands is provided. In addition, the implications of changes in the EEG frequency bands for the degree of unconsciousness are neither reported nor discussed. The occurrence of quiescent EEG with less than 10 % of the pre- stun EEG total power following the epileptiform activity is not considered/demonstrated as an indicator of unconsciousness. EEG results - The results in Table 3 of the submitted study show that there is no loss of consciousness within one second which should be the case according to the guidance (EFSA AHAW Panel, 2013a). An exposure to the stunning parameters for 15 seconds prior to the onset of unconsciousness is unacceptably long. There is no information on the absence of pain to the animals before the onset of unconsciousness. Therefore, the intervention does not fulfil the requirements of stunning, i.e. induction of immediate loss of consciousness without causing avoidable pain, distress and suffering. Animal-based measures to detect onset of unconsciousness (EFSA AHAW Panel, 2013a) are immediate onset of tonic seizures and apnoea following electrical water bath stunning – these were not reported in the study. Instead, the study reports resumption of breathing as the earliest sign of recovery of consciousness. However, in the absence of any evidence of epileptiform activity in the brain, or tonic seizures, the resumption of breathing alone cannot be used as an indicator of a return to consciousness. This is because electro-immobilisation can also produce apnoea followed by recovery of breathing without loss of consciousness. Therefore, recovery of breathing on its own is not a reliable indicator.
  • 8. Electrical poultry waterbath stunning parameters EFSA Journal 2014;12(7):3745 8 According to Council Regulation (EC) No 1099/20094, electrical stunning of animals, including waterbath stunning of poultry, must induce generalised epileptiform activity in the EEG. This is because the occurrence of epileptiform EEG activity indicates successful induction of unconsciousness following electrical stunning. Scientific literature concerning epilepsy in humans indicates that focal or partial epilepsy involving a group of neurons, region of the brain or one cerebral hemisphere is not always associated with unconsciousness (e.g. see Lux et al., 2002). On the other hand, a kind of generalised epilepsy, involving both cerebral hemispheres, that is always associated with unconsciousness in humans is grand mal (e.g. ILAE, 1981). Techniques for the classification of EEG signals for identification of epilepsy in humans have been developed (Kulkarni, 2013), but have not been tested under electrical stunning situations. Nevertheless, occurrence of generalised epilepsy following electrical stunning can be recognised from the occurrence of highly synchronised 8 to 13 Hz electrical activity in the EEG of animals. However, there is some indication that a low frequency epileptiform activity occurs in poultry (Gregory, 1986). In any case, the epileptiform activity should always be followed by a quiescent EEG which is less than 10 % of the pre-stun power content (EFSA AHAW Panel, 2013a). 4.2.2.1. Conclusion The evidence presented in the submitted study showed that the intervention did not produce unconsciousness without causing avoidable pain, distress and suffering. 4.2.3. Study under slaughterhouse conditions The information provided in the submitted study was assessed following the procedure detailed in the EFSA guidance (EFSA AHAW Panel, 2013a). A detailed evaluation of the reported parameters in the submitted study is presented in Table 3 (Appendix). The basis for the conclusions drawn by the AHAW Panel is summarised below. Only those aspects that were not considered adequate are commented upon. Only one bird at a time was monitored - this is not representative of real slaughterhouse conditions, under which several chickens are stunned in the waterbath simultaneously. Therefore, this study cannot be considered representative of commercial slaughterhouse conditions. Start and end of EEG measurement - No additional details are reported beyond those provided for the laboratory study (which were inadequate – see above). EEG measurement - Exposure time is not reported. The results of EEG analysis considered the drop in power of the 2-30 Hz band in 1 second epochs and the drop in the ratio of the power in the delta band compared to the other bands before and after stunning. This is not mentioned in the method Section of the submitted study and these EEG parameters were not evaluated in the laboratory study. EEG recoding and analysis - Changes in the frequency bands are not always reliably demonstrated. The requirement is epileptiform EEG following stunning and the parameters are not sufficient to achieve this in the birds. It is reported that 15 seconds application produced epileptiform EEG for 15 seconds, but suppressed EEG did not follow. EEG results - Figure 7 of the submitted study is not clear regarding the number of birds used i.e. n = 32, whereas in the text (Section 2.1.1.2) it is stated that 30 animals were tested. Data on the average duration of unconsciousness presented in this figure is not based on the duration of epileptiform EEG. The EEG trace presented in Figure 11 of the submitted study does not show pre-stun EEG and therefore it is difficult to ascertain whether the ictal EEG is indeed epileptiform activity.
  • 9. Electrical poultry waterbath stunning parameters EFSA Journal 2014;12(7):3745 9 Animal-based measures to detect onset of unconsciousness – As noted above, recovery of breathing on its own is not a reliable indicator. Further, the results presented in Figure 9 of the submitted study are unclear (the number of n = 71 is not clear because in the method Section 2.1.1.2 it is stated that 30 birds were used in the commercial study under slaughterhouse conditions). Additional considerations - Commercial multiple bird electrical waterbath stunners contain many birds (e.g. 30). As birds enter a stunner supplied with a constant voltage, they form a continuously changing parallel electrical circuit (Sparrey et al., 1993). Under this situation, each bird will receive a current inversely proportional to the electrical resistance or impedance in the pathway. The effective electrical impedance can vary between birds, usually 1000 to 2600 Ohms in broilers and 1900 and 7000 Ohms in layer hens (Schütt-Abraham et al., 1987; Schütt-Abraham and Wormuth, 1991). In fact, most of the electrical impedance in the pathway between the electrified water bath and the earth is attributed to poor contact between the legs of the bird and the metal shackles. The implication of this is that tighter shackle-leg fittings will reduce the electrical impedance at the expense of increased suffering due to pain. However, as a result of the variable electrical impedance, it will be impossible to deliver to each bird in a water bath stunner the pre-set minimum current necessary to achieve humane stunning (Sparrey et al., 1992). 4.2.3.1. Conclusion The study carried out under slaughterhouse conditions applied the same intervention as the laboratory study. Therefore, it also fails to meet the eligibility criteria (EFSA AHAW Panel, 2013a). Further, since only one bird at a time was monitored, this study cannot be considered representative of commercial slaughterhouse conditions. 4.2.4. Absence of pain, distress and suffering until the loss of consciousness and sensibility The information provided in the submitted study was assessed following the procedure detailed in the EFSA guidance (EFSA AHAW Panel, 2013a). A detailed evaluation of the reported parameters in the submitted study is presented in Table 4 (Appendix). The basis for the conclusions drawn by the AHAW Panel is summarised below. Not all parameters apply because electrical stunning must induce immediate loss of consciousness. In the event of a prolonged application of an electric current below the threshold necessary to produce unconsciousness will cause pain and suffering. Only those aspects that were not considered adequate are commented upon. There is no evidence that the proposed intervention induced immediate unconsciousness. No description was provided, for either the laboratory or slaughterhouse studies, of how birds were anaesthetised when they were implanted with two electrodes positioned under the skullcap through the skin and skull onto the brain lobes for EEG recording as outlined buy the authors. A reference to a standard protocol for EEG measurement was not present. 4.2.4.1. Conclusion The results of study one showed clearly that the proposed electrical stunning parameters had to be applied for a minimum of 15 seconds to produce epileptiform activity in the EEG. This prolonged application of an electric current through the whole body of poultry, while the animal is still conscious, would cause pain, distress and suffering until the loss of consciousness. 4.2.5. Duration of unconsciousness and insensibility Council Regulation (EC) No 1099/20094 states that unconsciousness and insensibility induced by stunning should last until the moment of death. Studies in a controlled environment should determine the duration of unconsciousness and insensibility using EEG. Based upon the obtained results (e.g. the shortest time to recovery of consciousness observed minus two standard deviations), the maximal stun-to-stick/-kill time interval can be defined that guarantees unequivocal loss of consciousness and sensibility until the moment of death (EFSA, 2004). The applicability of the stun-to-stick/-kill interval
  • 10. Electrical poultry waterbath stunning parameters EFSA Journal 2014;12(7):3745 10 should then be analysed under slaughterhouse conditions using indicators recognising recovery of consciousness and sensibility that correlate with EEGs as established in controlled environment studies. It is acceptable that studies on alternative stunning parameters assess only the duration of unconsciousness as this will always precede the recovery of sensibility. In the submitted study, EEG was recorded as an indicator of onset of unconsciousness and the resumption of rhythmic breathing was taken as an indicator of return of consciousness following stunning in the laboratory study and in the study under slaughterhouse conditions. The results regarding the variables used to assess the duration of unconsciousness are not reported. However, conclusions about the duration of unconsciousness appear to be based on the occurrence of delta EEG activity. The minimum duration of unconsciousness was reported to be 11 seconds, which is too short to permit a feasible stun-to-stick interval. Further, it is also doubtful that recovery of consciousness could be avoided prior to neck cutting and/or during bleeding. This interpretation is also supported by the data concerning time to resumption of breathing (Figure 9 in the submitted study). The minimum time to resumption of breathing was reported to be 8 seconds following stunning. 4.2.5.1. Conclusion The submitted study clearly shows that the electrical stunning parameters failed to induce immediate unconsciousness in all the birds. The duration of unconsciousness achieved, even after 15 seconds of exposure to the electrical parameters, is not long enough to prevent recovery of consciousness before neck cutting or during bleeding. 4.3. Assessment of study two providing details on measurement of the electric current that flows into the bird brain The description of the methods for study two (Section 2.2.1) states that 11 birds were individually stunned and slaughtered. Electrodes were implanted in the brain of each dead bird. The relevance and rationale for this approach that is put forward is unsubstantiated. The current registered in the brain of a dead bird is irrelevant because the crucial aspect for studies such as this is to demonstrate that the intervention renders the birds unconscious and insensible to pain until the time of death. In addition, measurements made in the brain of dead animals do not give any indication of whether live birds are subjected to avoidable pain or suffering prior to the induction of unconsciousness by the intervention. Therefore, this experiment does not provide any relevant additional information. 5. Reporting quality 5.1. Assessment of the reporting quality of the submitted studies based on the selected parameters The assessed studies did not pass the eligibility assessment and, therefore, reporting quality was not assessed (EFSA AHAW Panel, 2013a). 6. Methodological quality 6.1. Quality assessment of the internal validity of the submitted studies The assessed studies did not pass the eligibility assessment and, therefore, methodological quality was not assessed (EFSA AHAW Panel, 2013a). CONCLUSIONS AND RECOMMENDATIONS CONCLUSIONS The study does not provide enough information upon which to base an assessment of the scientific approach and parameters tested.
  • 11. Electrical poultry waterbath stunning parameters EFSA Journal 2014;12(7):3745 11 Nonetheless, the information provided was sufficient to conclude that the birds were not rendered immediately unconscious by the intervention. Application of a current less than that required to induce immediate unconsciousness causes pain, distress and suffering. The study failed to demonstrate absence of pain and suffering until onset of unconsciousness. The minimum duration of unconsciousness was too short to ensure unconsciousness until death by bleeding. RECOMMENDATIONS The complexity of multiple bird electrical waterbath stunning systems used in poultry slaughterhouses, such as the one assessed here, are not conducive to maintaining good animal welfare and, therefore, alternatives should be developed/implemented. Studies such as the one assessed here should consider the internationally accepted principles referred to as the 3 Rs (replacement, reduction and refinement according to Directive 2010/63/EU6) which recommend approaches to minimize the use of animals for experimental purposes in line with the European Regulation on protection of animals used for scientific purposes. REFERENCES ILAE (Commission on Classification and Terminology of the International League Against Epilepsy), 1981. Proposal for revised clinical and electroencephalographic classification of epileptic seizures. Epilepsia, 22, 489 - 501. EFSA (European Food Safety Authority), 2004. Welfare aspects of the main systems of stunning and killing the main commercial species of animals. The EFSA Journal 2004, 45, 1–29. EFSA (European Food Safety Authority), 2005. Aspects of the biology and welfare of animals used for experimental and other scientific purposes. The EFSA Journal 2005, 292, 1–46. EFSA (European Food Safety Authority), 2006. Opinion on the welfare aspects of the main systems of stunning and killing applied to commercially farmed deer, goats, rabbits, ostriches, ducks, geese and quail. The EFSA Journal 2006, 326, 1-18. EFSA (European Food Safety Authority), 2013. Outcome of a public consultation on the Draft Guidance on the assessment criteria for studies evaluating the effectiveness of stunning interventions regarding animal protection at the time of killing. EFSA supporting publication 2013:EN-530, 20 pp. EFSA AHAW Panel (EFSA Panel on Animal Health and Welfare), 2012. Scientific Opinion on electrical requirements for waterbath equipment applicable for poultry. EFSA Journal 2012;10(6):2757, 80 pp. doi:10.2903/j.efsa.2012.2757 EFSA AHAW Panel (EFSA Panel on Animal Health and Welfare), 2013a. Guidance on the assessment criteria for studies evaluating the effectiveness of stunning interventions regarding animal protection at the time of killing. EFSA Journal 2013;11(12):3486, 41 pp. doi:10.2903/j.efsa.2013.3486 EFSA AHAW Panel (EFSA Panel on Animal Health and Welfare), 2013b. Scientific Opinion on monitoring procedures at slaughterhouses for poultry. EFSA Journal 2013;11(12):3521, 65 pp. doi:10.2903/j.efsa.2013.3521 Gregory NG, 1986. The physiology of electrical stunning and slaughter. In: Humane Slaughter of Animals for Food Humane Slaughter of Animals for Food: Proceedings of a Symposium Organized by Universities Federation for Animal Welfare, Held at the Meeting Rooms, Zoological Society of 6 Directive 2010/63/EU of the European Parliament and of the Council of 22 September 2010 on the protection of animals used for scientific purposes. OJ L 276, 20.10.2010, p. 33-79.
  • 12. Electrical poultry waterbath stunning parameters EFSA Journal 2014;12(7):3745 12 London, Regent's Park, 18th September 1986. Universities Federation for Animal Welfare (Publishers), UK, 3-12. Kulkarni SPK, 2013. EEG signal classification for Epilepsy Seizure Detection using Improved Approximate Entropy. International Journal of Public Health Science, 2, 23 - 32. Lux S, Kurthen M, Helmstaedter C, Hartje W, Reuber M and Elger CE, 2002. The localizing value of ictal consciousness and its constituent functions: A video-EEG study in patients with focal epilepsy. Brain, 125, 2691- 2698. Ruffini G1, Wendling F, Merlet I, Molaee-Ardekani B, Mekonnen A, Salvador R, Soria-Frisch A, Grau C, Dunne S and Miranda PC, 2013. Transcranial current brain stimulation (tCS): models and technologies. IEEE Transactions on Neural Systems and Rehabilitation Engineering, 21, 333-345. Schütt-Abraham I, Wormuth HJ and Fessel J, 1987. Vergleichende Untersuchungen zur tierchutzgerechten Elektrobetäubung verschiedener Schlachtgeflügelarten. Berliner und Münchener Tierärztliche Wochenschrift, 100, 332-340. Schütt-Abraham I and Wormuth, H. J. 1991. Anforderungen an eine tierschutzgerechte elektrische Betäubung von Schlachtgeflügel. Rundeschau für Fleischhygiene und Lebensmittelüberwachung, 43, 7-8. Sparrey JM, Kettlewell PJ and Paice ME, 1992. A model of current pathways in electrical waterbath stunners used for poultry. British Poultry Science, 33, 907-916. Sparrey JM, Kettlewell PJ, Paice ME and Whetlor WC, 1993. Development of a constant current waterbath stunner for poultry processing. Journal of Agricultural Engineering Research, 56, 267- 274.
  • 13. Electrical poultry waterbath stunning parameters EFSA Journal 2014;12(7):3745 13 APPENDIX Assessment of eligibility criteria Table 1: Parameters assessed when applying a stunning intervention based on electrical waterbath stunning, based on Annex I of Council Regulation (EC) No 1099/20094 and on further details of requirements as determined by the EFSA guidance (corresponding to Table 4 (EFSA AHAW Panel, 2013a)). Parameter Component Description presented in study (all specifications should be in internationally recognised units) Information provided in Section 5 was not taken into account unless supported in the body of text in the submitted manuscript Fulfilment criterion (yes, no or not applicable) Minimum current (A or mA) Current type Alternating current Yes Waveform Square waves 50 % Duty cycle Yes Minimum current (a) 104 ± 3,88 mA r.m.s Yes Minimum voltage (V) Exposed minimum voltage (V) (a) 125,86 ± 3,88 r.m.s Yes Delivered minimum voltage (V) (a) Automatic process for voltage distribution according to the whole system resistance. No Frequency (Hz) Maximum frequency (Hz) 590/600 Yes Minimum frequency (Hz) 589.78 ± 0.63 Yes Frequency of calibration of the equipment In the manuscript, Section 2.1.1.1 it is mentioned that ‘the electrical parameters were verified using a hand-held digital multimeter (usually called ‘Galinha Electrônica’) made by Fluxo® No Prevention of electrical shocks before stunning None Not applicable Minimising pain at shackling None Not applicable
  • 14. Electrical poultry waterbath stunning parameters EFSA Journal 2014;12(7):3745 14 Table 1: Parameters assessed when applying a stunning intervention based on electrical waterbath stunning, based on Annex I of Council Regulation (EC) No 1099/20094 and on further details of requirements as determined by the EFSA guidance (corresponding to Table 4 (EFSA AHAW Panel, 2013a)) (continued) Parameter Component Description presented in study (all specifications should be in internationally recognised units) Information provided in Section 5 was not taken into account unless supported in the body of text in the submitted manuscript Fulfilment criterion (yes, no or not applicable) Optimisation of the current flow Shackles Wetting the leg shackle contact Contact with earth bar None No Waterbath and electrode characteristics None No Water conductivity None No Electricity source characteristics None No Electrical resistance/impedance Mixed flocks – male and female, average 3.3 kg, Ross and Cobb strains No Maximum shackle duration before stunning None No Minimum time of exposure for each bird According to Table 3, exposure time varied between 1 and 15 seconds in the laboratory study. Only 15 seconds exposure produced epileptiform activity in all the birds (n = 5). No. Immersion of the birds up to the base of the wings None No Maximum stun-to- stick/kill interval(s) for frequency over 50 Hz(a, b) In the method Section 2.1.2 it is stated that the birds underwent ventral cut 10 seconds after leaving the waterbath. In the results Section it is mentioned that bleeding takes place within 12, 10 and 8 seconds, respectively, after stunning (text Section 3.1.1.2 ‘physical signs’). No (a): Provide information on mean or median and range and standard deviation or interquartile range. (b): In case of simple stunning.
  • 15. Electrical poultry waterbath stunning parameters EFSA Journal 2014;12(7):3745 15 Table 2: Information provided in the laboratory study by the submitted study in relation to the onset of unconsciousness and insensibility (3.2.1 of EFSA guidance (EFSA AHAW Panel, 2013a)) Laboratory study Information provided in the submitted manuscript Is the criterion described/met adequately? (yes, no or not possible to assess) Start and end of EEG measurement In the submitted study the information is provided that the EEG was recorded 80 seconds before and 80 seconds after stunning before sticking (Section 2.1.1.1). Yes EEG measurement For the EEG registration, the birds were individually implanted with 2 needle electrodes (55 % silver, 21 % copper, 24 % zinc of 10 mm x 1.5 mm diameter) positioned under the skullcap through the skin and skull onto the brain lobes (0.3 cm left and right of the sagittal suture and 0.5 mm toward an imaginary transverse line at the caudal margin of the eyes). The electrodes were sealed using adhesive tape. Yes EEG recording analysis Information from last paragraph of Section 2.1.1.1: The EEG was collected at a sample frequency of 120 Hz and the digital signal obtained was processed using fast Fourrier transformation (FFT), implemented using the MATLAB tool to obtain the frequency spectrum of different stretches associated with different events on the EEG. Several successive artifact-free stretches were also analyzed and filtered into four frequency bands: delta (0.3-4 Hz), theta (4-8 Hz), alpha (8-12 Hz) and beta (12-30 Hz). Elliptical filters integrated onto a visual tool developed at the MATLAB® were used. In each of these frequency bands, the energy of the signal obtained was calculated using MATLAB® signal processing toolbox. Spike-and-slow-wave-complex (SASWC) (known as petite mal) and spike-or-sharp-wave (SOSW) (common to several different types of epilepsy) are referred in the results Section (3.1.1.1) No EEG results In the submitted study one sample recording of epileptic EEG obtained after 15 seconds stunning is shown in Figure 5. The epileptic ictal stage has 12 seconds of duration. However the legend of the figure mentions 15 seconds of electrical exposure. Epileptic patterns in the EEG were detected by analyzing the spectral power density. The results show that the electrical parameters tested will induce epilepsy in all birds after 15 seconds of exposure to the electrical current and that the energy of the epilepsy generated depends on the time of exposure to the electric shock. In fact, the tested parameters did not cause epilepsy within 1 second in 100 % of the chickens. In fact an application of the chosen current parameters for up to 12 seconds failed to induce epileptiform EEG in all the birds. A minimum exposure time of 15 seconds is needed to result in unconsciousness – there is no evidence that the animals are not subjected to avoidable pain during the stun. No
  • 16. Electrical poultry waterbath stunning parameters EFSA Journal 2014;12(7):3745 16 Table 3: Information provided in the study under slaughterhouse conditions by the submitted study in relation to the onset of unconsciousness and insensibility (3.2.1 of EFSA guidance (EFSA AHAW Panel, 2013a)) Study under slaughterhouse conditions Information provided Is the criterion described/met adequately? (yes, no or not possible to assess) Start and end of EEG measurement In the submitted study it is stated that the same procedure as in the laboratory was followed. No EEG measurement In the submitted study it is stated that the same procedure as in the laboratory was followed. A separate Section of the submitted study describes the continued evaluation of the EEG of chickens during bleeding. No EEG recording analysis In the submitted study it is outlined that the EEG analysis considered the drop in power of the 2-30 Hz band in 1 second epochs and the drop in the ratio of the power in the Delta band compared to the other bands before and after stunning. Not possible to assess EEG results In the submitted study data showed an average time of unconsciousness of 32 seconds with a standard deviation of 14 seconds. Such variation in is expected due to individual impedance variations which influence the current that the bird receives while immersed in the waterbath. The distribution of the time of chicken unconsciousness following stunning is shown in Figure 7. Results of continued evaluation of the EEG of chickens during bleeding show that the EEG of birds bled by a deep ventral cut (2T) after stunning in Figure 11. The EEG at the moment of the cut is also marked by epileptic forms. Following cutting, the amplitude of the EEG drops considerably. After 35 seconds, the bird's EEG reaches a very low amplitude value, providing evidence of death. In the submitted study, Figure 12 reports the distribution of time between stunning and death. No ABM to detect onset of unconsciousness In the submitted study resumption of rhythmic breathing as a sign of return of consciousness. A paragraph about physical signs of unconsciousness after stunning is reported in Figure 9. Evidence of death through observation of dilated pupils, absence of breathing and relaxation of the neck and wings during bleeding was performed. No
  • 17. Electrical poultry waterbath stunning parameters EFSA Journal 2014;12(7):3745 17 Table 4: Information provided by the submitted study in relation to animal based measures (ABM) associated with pain, distress and suffering during the induction of unconsciousness (3.2.1 of EFSA guidance (EFSA AHAW Panel, 2013a)) Response type Groups of ABM Study under laboratory conditions Study under slaughterhouse conditions Do the ABMs suggest pain, distress and suffering (yes, no or not possible to assess, not appliable) Behaviour Vocalisation Information was not provided Information was not provided No Postures and movements Information was not provided Information was not provided No General behaviour Information was not provided Information was not provided No Physiological response Hormones concentration Information was not provided Information was not provided Not applicable for electrical stunning interventions Blood metabolites Information was not provided Information was not provided Not applicable for electrical stunning interventions Autonomic responses Resumption of rhythmic breathing Resumption of rhythmic breathing In this context this ABM is not related to absence of pain, only an indicator for recovery of consciousness. Neurological response Brain activity EEG was measured EEG was measured Not applicable for electrical stunning interventions
  • 18. Electrical poultry waterbath stunning parameters EFSA Journal 2014;12(7):3745 18 ABBREVIATIONS ABM Animal-based measure AHAW Panel EFSA Panel on Animal Health and Welfare EC European Commission EFSA European Food Safety Authority ECoG Electrocorticogram EEG Electroencephalogram r.m.s. root mean square