We are a young company promoted by IIT Alumni. We provide services which helps individuals and organizations to take the "Green Route" for cleaner future. Our services includes Energy Audit, EPCM for Renewable energy (Solar & Bio-mass) Projects, Technology Evaluation (Research & Analysis) and carbon management services(footprint, mitigation and branding)
1. Energy Audits
&
Renewable Energy
Potential Assessment
2. About
• A young company promoted by Indian Institute of
Technology (IIT) Roorkee Alumni
• Our Services help individuals & organizations to take
the “Green Route” for a cleaner future
• Our mantra is Empowering clean & green power
3. Our Services
• Energy Audits
• Renewable Energy (Solar & Biomass) Consultancy
• Renewable Energy Potential Assessments
• Turnkey solutions
• Technology evaluation, research & analysis
• Carbon Management Services
• Footprinting
• Mitigation
• Branding
4. Energy Audits
Energy audits can be classified as under:
• Walk-through audit: A preliminary inspection of site to observe the
various processes and identify glaring areas of energy waste or inefficiency
• General audit: A detailed inspection of all energy consuming processes
backed up by past operating data. Identification of all energy conservation
measures followed by detailed financial analysis for each measure
• Investment-grade audit: Projected operating savings from the
implementation of energy projects are developed such that they provide a
high level of confidence. Extensive attention is given to understanding not
only the operating characteristics of all energy consuming systems, but
also situations that cause load profile variations on short and long term
basis.
5. Energy Audits
Effective energy management strategy
• O&M recommendations
• Adoption of energy efficient equipments
• Analysis of energy demand growth
• Consumption Optimization Training (COT)- Training personnel at site
for good energy use practices
6. Methodology of energy audit
Meeting with the
Identification of key Meeting with the Understanding the
facility incharge &
personnel of the personnel and their functioning of the
defining the scope
facility interview facility
of work
Reviewing the data Collection of facility
Collection of
collected & blueprints, both Walk through survey
historical data of
identifying focus architectural & of the whole facility
energy consumption
areas electrical
Final presentation
Further investigation Data Analysis &
about the audit to
of focus areas report preparation
facility incharge(s)
Methodology followed in General Energy Audit & not in Preliminary Energy Audit
7. Renewable Energy Potential Assessment
(REPA)
Dependence on conventional energy can be greatly reduced with
the use of modern renewable energy systems.
Ambicales has worked extensively & studied about various
renewable energy technologies that can be applied for offsetting
conventional energy demand in buildings, school/college
campus, temples, industries, etc.
8. Renewable Energy Potential Assessment
(REPA)
We look at facility specific energy demands that can be offset
by the following:
• Solar energy systems
• Solar photovoltaic
• Solar thermal
• Biomass energy systems
• Biomass gasification
• Biogas Digester
• Hybrid energy systems
9. Methodology of REPA
Meeting with the
Identification of key Meeting with the Understanding the
facility incharge &
personnel of the personnel and their various types of
defining the scope of
facility interview energy usage
work
Reviewing data &
Collection of historical
finding compatible Collection of
Walk through survey data of energy
Renewable Energy & architectural blue
of the whole facility consumption & waste
Waste to energy prints
generation
systems
Surveying of potential
Final presentation
location(s) for Data Analysis & report
about the audit to
installing RE & W2E preparation
facility incharge(s)
systems
10. Applications of Renewable energy and waste to
energy systems
• Electricity production • Sewage based • Cooking purposes
• Thermal processes • Effluents • Thermal application
• Cooking purposes • Lighting application
Biomass Effluent
Biogas Digester
Gasification treatment plant
• Electricity generation • Thermal Processes • Electricity production
• Water pumping (primarily in Industries)
• External lights/ Garden • Hot water generation
lights • Steam based cooking
• Direct cooking purposes
Solar Small wind
Solar Thermal
Photovoltaic turbines
11. Why
• Technical Support from IIT Delhi, IIT Roorkee, IIT Madras & IIT
Kharagpur
• Extensively working in renewable & energy efficient
technologies
• Field experience for Energy Audits & REPAs strengthen our
Footprinting & Mitigation service profiles
• Ambicales has been profiled by Economic Times, Hindustan
Times, JAM Magazine, Deccan Chronicle, etc
12. Projects served
• Pre-Feasibility Study for Energy Efficiency and Renewable Energy
Yamaha, Faridabad measures at Faridabad Plant
The Doon School, • Walk through audit and Renewable Energy Potential Assessment
(REPA) under Special Area Demonstration Project (SADP) by the
Dehradun Ministry of New and Renewable Energy (MNRE)
Gurukul Kangadi • Renewable Energy Potential Assessment (REPA) under Special
Vishwavidyalaya, Area Demonstration Project (SADP) by the Ministry of New and
Haridwar Renewable Energy (MNRE)
Winrock International • Secondary research and analysis of energy saving equipments
for the SIDBI Financing Scheme for Energy Saving Projects in
India MSME Sector
Ankur Scientific Energy
• Marketing Outreach for North India for Biomass Gasifiers
Technologies Pvt. Ltd.
13. Projects served
S.R. Corporate • Uttarakhand Renewable Energy Masterplan Project
Consultant (P) Ltd.
• Marketing Outreach for North India for Arun Solar (Solar
Clique Technologies Pvt. Thermal system)
• Feasibility Study for 1 MW biomass based power plant in
Milestone Gears (P) Ltd. Haryana
• Building Energy Audit; Building energy audit at CISF building,
Epic Energy Limited Patna
14. Our Clients
Milestone Gears (P) Ltd.
Yamaha Motors, Faridabad Winrock International India
S.R. Corporate Consultant
(P) Ltd.
Ankur Scientific Energy Technologies Uttarakhand Renewable Energy
Pvt. Ltd. Development Agency (UREDA)
Clique Technologies Pvt. Ltd. Bureau of Energy Efficiency (BEE)
15. Case study
A new 70 bed hospital in Bijapur, Karnataka has a sanctioned
load of 50 kVA.
The following describes in brief the walk through audit
conducted at the hospital.
16. Case study
Power Factor Correction
Power factor history of the hospital (year 2009)
Units consumed Recorded power
Month Penalty (Rs.)**
(kWh) factor*
January 8000 0.78 2880
February 9634 0.80 2890.20
March 10546 0.81 2847.42
April 11235 0.76 4718.70
May 10987 0.82 2636.88
June 10762 0.86 1291.44
*Power factor specified by utility is 0.90.
**Penalty of 3 paisa per unit consumed is levied for every reduction of pf by 0.01 by
0.90 lag
17. Case study
Average power factor of 0.80 will be considered for calculations.
Average energy consumption over the period is 10035.4 kWh.
Average power factor penalty over the period is Rs. 2877.44.
The solution is to install Power Factor Correction (PFC). It is
recommended that the PFC unit be of 15 kVAR capacity. The
cost of the unit is approximately Rs. 20000.
Projected savings are Rs. 34529/yr with a simple payback period
(SPP) of 0.57 years or 7 months.
18. Case study
Motor Load Test
A detailed motor load study was undertaken on all continuously
operating motors, with help of clamp on energy meter to
measure instantaneous parameters.
Star mode operation of under loaded motors (which are loaded
below 45 % of the rated capacity) results in improved
operating efficiency.
The following motors at the hospital were under-loaded
Rated Power Actual Power Power after star Saving potential
Motor
(kW) (kW) connection (kW) (kW)
Basement water
3.72 1.4 0.47 0.93
pumping 1
Basement water
1.5 0.52 0.17 0.35
pumping 2
19. Case study
Total saving potential (kW) 1.28
Daily operating hours (hrs) 16
Number of operating days in a year (days) 365
Saving* Rs. 37376/year
*Average electricity cost per kWh = Rs. 5
20. Equipments required for Energy Audit
Lux meter x 2
Digital power analyser
Steam and air leak detector
Vane type Anemometer
Flow meter x 2
Clamp-on power meter
Digital tachometer
Digital hygrometer
21. Costs
• Equipment cost for complete building energy audit
(electrical and HVAC)
– Rs. 8 lakhs
• Ambicales costs
– Fixed cost Rs. 20,000/-
– Rs. 25/m2 – Rs. 30/m2 of built up area
22. Web: www.ambicales.com
Email: info@ambicales.com
Contact: +91-9718800615
+91-9811708911
Address: H -5/56,
Near Ryan International School.
Sector 11,
Rohini ,
New Delhi- 85